Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Comput Methods Programs Biomed ; 206: 106105, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33979752

RESUMO

PURPOSE: The aim of the current study is to develop a prediction model for glucose levels applicable for all patients admitted to the ICU with an expected ICU stay of at least 24 h. This model will be incorporated in a closed-loop glucose system to continuously and automatically control glucose values. METHODS: Data from a previous single-center randomized controlled study was used. All patients received a FreeStyle Navigator II subcutaneous CGM system from Abbott during their ICU stay. The total dataset was randomly divided into a training set and a validation set. A glucose prediction model was developed based on historical glucose data. Accuracy of the prediction model was determined using the Mean Squared Difference (MSD), the Mean Absolute Difference (MAD) and a Clarke Error Grid (CEG). RESULTS: The dataset included 94 ICU patients with a total of 134,673 glucose measurements points that were used for modelling. MSD was 0.410 ± 0.495 for the model, the MAD was 5.19 ± 2.63 and in the CEG 99.8% of the data points were in the clinically acceptable regions. CONCLUSION: In this study a glucose prediction model for ICU patients is developed. This study shows that it is possible to accurately predict a patient's glucose 30 min ahead based on historical glucose data. This is the first step in the development of a closed-loop glucose system.


Assuntos
Estado Terminal , Glucose , Glicemia , Automonitorização da Glicemia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA