1.
Clin Orthop Relat Res ; 469(6): 1743-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21318629

RESUMO

BACKGROUND: Radiographic diagnosis and followup studies of developmental dysplasia of the hip are commonly performed by measuring the acetabular index on radiographs using Hilgenreiner's method. The outcome of the measurement, however, depends on the orientation of the subject's pelvis relative to the xray source. The influence of pelvic rotation and tilt on the measurement error has been evaluated separately but not in combination. QUESTIONS/PURPOSES: We asked whether (1) combinations of pelvic rotation and tilt introduced systematic error in acetabular index measurement in a reproducible way, and (2) ratios proposed to evaluate either pelvic rotation (R(rotation)) or pelvic tilt (R(tilt)) are influenced by pelvic tilt and rotation, respectively. METHODS: Radiographic measurements of the acetabular index, R(rotation), and R(tilt) were performed on digitally reconstructed radiographs of one high-resolution three-dimensional CT dataset with various combinations of pelvic rotation and tilt. RESULTS: For rotations and tilt up to 12°, the average systematic errors in the acetabular index varied from -8.8° to 4.5°. Negative and positive error values can be interpreted as underestimations and overestimations of the acetabular index, respectively. Errors in acetabular index measurements were acceptable for R(rotation) values between 1.0 and 2.0 and R(tilt) values between 1.1 and 1.8. CONCLUSIONS: To limit the systematic error in assessing the acetabular index caused by pelvic misalignment, we recommend only radiographs acquired with ± 4° rotation and ± 4° tilt be considered acceptable.


Assuntos
Erros de Diagnóstico , Luxação Congênita de Quadril/diagnóstico por imagem , Quadril/diagnóstico por imagem , Ossos Pélvicos/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Acetábulo/diagnóstico por imagem , Criança , Humanos , Rotação
2.
Phys Med Biol ; 56(4): 1031-43, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21258138

RESUMO

Spatial and soft tissue information provided by magnetic resonance imaging can be very valuable during image-guided procedures, where usually only real-time two-dimensional (2D) x-ray images are available. Registration of 2D x-ray images to three-dimensional (3D) magnetic resonance imaging (MRI) data, acquired prior to the procedure, can provide optimal information to guide the procedure. However, registering x-ray images to MRI data is not a trivial task because of their fundamental difference in tissue contrast. This paper presents a technique that generates pseudo-computed tomography (CT) data from multi-spectral MRI acquisitions which is sufficiently similar to real CT data to enable registration of x-ray to MRI with comparable accuracy as registration of x-ray to CT. The method is based on a k-nearest-neighbors (kNN)-regression strategy which labels voxels of MRI data with CT Hounsfield Units. The regression method uses multi-spectral MRI intensities and intensity gradients as features to discriminate between various tissue types. The efficacy of using pseudo-CT data for registration of x-ray to MRI was tested on ex vivo animal data. 2D-3D registration experiments using CT and pseudo-CT data of multiple subjects were performed with a commonly used 2D-3D registration algorithm. On average, the median target registration error for registration of two x-ray images to MRI data was approximately 1 mm larger than for x-ray to CT registration. The authors have shown that pseudo-CT data generated from multi-spectral MRI facilitate registration of MRI to x-ray images. From the experiments it could be concluded that the accuracy achieved was comparable to that of registering x-ray images to CT data.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Estudos de Viabilidade , Humanos
3.
Med Phys ; 37(4): 1884-92, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443510

RESUMO

PURPOSE: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. METHODS: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. RESULTS: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. CONCLUSIONS: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Algoritmos , Animais , Área Sob a Curva , Cães , Desenho de Equipamento , Análise de Fourier , Humanos , Imageamento por Ressonância Magnética/métodos , Modelos Estatísticos , Distribuição Normal , Radiografia/métodos , Reprodutibilidade dos Testes , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA