Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 255
Filtrar
1.
J Cardiovasc Magn Reson ; : 101049, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38878969

RESUMO

BACKGROUND: The Plaque at RISK (PARISK) study demonstrated that patients with a carotid plaque with intraplaque hemorrhage (IPH) have an increased risk of recurrent ipsilateral ischemic cerebrovascular events. It was previously reported that symptomatic carotid plaques with IPH showed higher IPH signal intensity ratios (SIR) and larger IPH volumes than asymptomatic plaques. We explored whether IPH SIR and IPH volume are associated with future ipsilateral ischemic cerebrovascular events beyond the presence of IPH. METHODS: TIA and ischemic stroke patients with mild-to-moderate carotid stenosis and an ipsilateral IPH-positive carotid plaque (n=89) from the PARISK study were included. The clinical endpoint was a new ipsilateral ischemic cerebrovascular event during 5 years of follow-up, while the imaging-based endpoint was a new ipsilateral brain infarct on brain MRI after 2 years (n=69). Trained observers delineated IPH, a hyperintense region compared to surrounding muscle tissue on hyper T1-weighted MR images. The IPH SIR was the maximal signal intensity in the IPH region divided by the mean signal intensity of adjacent muscle tissue. The associations between IPH SIR or volume and the clinical and imaging-based endpoint were investigated using Cox-proportional hazard models and logistic regression, respectively. RESULTS: During 5.1 (interquartile range (IQR): 3.1-5.6) years of follow-up, 21 ipsilateral cerebrovascular ischemic events were identified. Twelve new ipsilateral brain infarcts were identified on the 2-year neuro MRI. There was no association for IPH SIR or IPH volume with the clinical endpoint (HR: 0.89 [95% CI: 0.67-1.10] and HR: 0.91 [0.69-1.19] per 100µl increase, respectively) nor with the imaging-based endpoint (OR: 1.04 [0.75-1.45] and OR: 1.21 [0.87-1.68] per 100µl increase, respectively). CONCLUSIONS: IPH SIR and IPH volume were not associated with future ipsilateral ischemic cerebrovascular events. Therefore, quantitative assessment of IPH does not seem to provide additional value beyond the presence of IPH for stroke risk assessment. Trial registration The PARISK study was registered on ClinicalTrials.gov with ID NCT01208025 on 21 September 2010 (https://clinicaltrials.gov/study/NCT01208025).

2.
Am J Cardiol ; 221: 37-43, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38552710

RESUMO

We aimed to correlate left atrial appendage (LAA) structure and function with the history of stroke/transient ischemic attack (TIA) in patients with atrial fibrillation (AF). We analyzed the data of 649 patients with AF who were scheduled for catheter ablation. Patients underwent cardiac computed tomography and transesophageal echocardiography before ablation. The LAA morphologies depicted by cardiac computed tomography were categorized into 4 groups: cauliflower, chicken wing, swan, and windsock shapes. The mean age was 61.3 ± 10.5 years, 33.9% were women. The prevalence of stroke/TIA was 7.1%. After adjustment for the main risk factors, the LAA flow velocity ≤35.3 cm/s (odds ratio [OR] 2.18, 95% confidence interval [CI] 1.09 to 4.61, p = 0.033) and the swan LAA shape (OR 2.69, 95% CI 0.96 to 6.86, p = 0.047) independently associated with a higher risk of stroke/TIA, whereas the windsock LAA morphology proved to be protective (OR 0.32, 95% CI 0.12 to 0.77, p = 0.017) compared with the cauliflower LAA shape. Comparing the differences between the LAA morphology groups, we measured a significantly smaller LAA orifice area (389.3 ± 137.7 mm2 in windsock vs 428.3 ± 158.9 ml in cauliflower, p = 0.021) and LAA volume (7.4 ± 3.0 mm2 in windsock vs 8.5 ± 4.8 mm2 in cauliflower, p = 0.012) in patients with windsock LAA morphology, whereas the LAA flow velocity did not differ significantly. Reduced LAA function and swan LAA morphology were independently associated with a higher prevalence of stroke/TIA, whereas the windsock LAA shape proved to be protective. Comparing the differences between the various LAA morphology types, significantly lower LAA volume and LAA orifice area were measured in the windsock LAA shape than in the cauliflower LAA shape.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ecocardiografia Transesofagiana , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/epidemiologia , Pessoa de Meia-Idade , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Idoso , Ablação por Cateter , Tomografia Computadorizada por Raios X , Estudos Retrospectivos
3.
Eur Heart J Cardiovasc Imaging ; 25(7): 929-936, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38306632

RESUMO

AIMS: To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.


Assuntos
Insuficiência da Valva Aórtica , Imagem Cinética por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos Prospectivos , Idoso de 80 Anos ou mais , Idoso , Imagem Cinética por Ressonância Magnética/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo , Complicações Pós-Operatórias/diagnóstico por imagem , Índice de Gravidade de Doença , Estudos de Coortes
5.
Front Cardiovasc Med ; 11: 1279298, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38374997

RESUMO

Introduction: Cardiac magnetic resonance (CMR) is of diagnostic and prognostic value in a range of cardiopulmonary conditions. Current methods for evaluating CMR studies are laborious and time-consuming, contributing to delays for patients. As the demand for CMR increases, there is a growing need to automate this process. The application of artificial intelligence (AI) to CMR is promising, but the evaluation of these tools in clinical practice has been limited. This study assessed the clinical viability of an automatic tool for measuring cardiac volumes on CMR. Methods: Consecutive patients who underwent CMR for any indication between January 2022 and October 2022 at a single tertiary centre were included prospectively. For each case, short-axis CMR images were segmented by the AI tool and manually to yield volume, mass and ejection fraction measurements for both ventricles. Automated and manual measurements were compared for agreement and the quality of the automated contours was assessed visually by cardiac radiologists. Results: 462 CMR studies were included. No statistically significant difference was demonstrated between any automated and manual measurements (p > 0.05; independent T-test). Intraclass correlation coefficient and Bland-Altman analysis showed excellent agreement across all metrics (ICC > 0.85). The automated contours were evaluated visually in 251 cases, with agreement or minor disagreement in 229 cases (91.2%) and failed segmentation in only a single case (0.4%). The AI tool was able to provide automated contours in under 90 s. Conclusions: Automated segmentation of both ventricles on CMR by an automatic tool shows excellent agreement with manual segmentation performed by CMR experts in a retrospective real-world clinical cohort. Implementation of the tool could improve the efficiency of CMR reporting and reduce delays between imaging and diagnosis.

6.
J Cardiovasc Magn Reson ; 26(1): 100003, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38211658

RESUMO

BACKGROUND: 4D flow MRI enables assessment of cardiac function and intra-cardiac blood flow dynamics from a single acquisition. However, due to the poor contrast between the chambers and surrounding tissue, quantitative analysis relies on the segmentation derived from a registered cine MRI acquisition. This requires an additional acquisition and is prone to imperfect spatial and temporal inter-scan alignment. Therefore, in this work we developed and evaluated deep learning-based methods to segment the left ventricle (LV) from 4D flow MRI directly. METHODS: We compared five deep learning-based approaches with different network structures, data pre-processing and feature fusion methods. For the data pre-processing, the 4D flow MRI data was reformatted into a stack of short-axis view slices. Two feature fusion approaches were proposed to integrate the features from magnitude and velocity images. The networks were trained and evaluated on an in-house dataset of 101 subjects with 67,567 2D images and 3030 3D volumes. The performance was evaluated using various metrics including Dice, average surface distance (ASD), end-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (LVEF), LV blood flow kinetic energy (KE) and LV flow components. The Monte Carlo dropout method was used to assess the confidence and to describe the uncertainty area in the segmentation results. RESULTS: Among the five models, the model combining 2D U-Net with late fusion method operating on short-axis reformatted 4D flow volumes achieved the best results with Dice of 84.52% and ASD of 3.14 mm. The best averaged absolute and relative error between manual and automated segmentation for EDV, ESV, LVEF and KE was 19.93 ml (10.39%), 17.38 ml (22.22%), 7.37% (13.93%) and 0.07 mJ (5.61%), respectively. Flow component results derived from automated segmentation showed high correlation and small average error compared to results derived from manual segmentation. CONCLUSIONS: Deep learning-based methods can achieve accurate automated LV segmentation and subsequent quantification of volumetric and hemodynamic LV parameters from 4D flow MRI without requiring an additional cine MRI acquisition.


Assuntos
Automação , Circulação Coronária , Aprendizado Profundo , Ventrículos do Coração , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Valor Preditivo dos Testes , Função Ventricular Esquerda , Humanos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Velocidade do Fluxo Sanguíneo , Reprodutibilidade dos Testes , Imagem de Perfusão do Miocárdio/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Bases de Dados Factuais
7.
JACC Clin Electrophysiol ; 10(4): 637-650, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38276927

RESUMO

BACKGROUND: Voltage mapping to detect ventricular scar is important for guiding catheter ablation, but the field-of-view of unipolar, bipolar, conventional, and microelectrodes as it relates to the extent of viable myocardium (VM) is not well defined. OBJECTIVES: The purpose of this study was to evaluate electroanatomic voltage-mapping (EAVM) with different-size electrodes for identifying VM, validated against high-resolution ex-vivo cardiac magnetic resonance (HR-LGE-CMR). METHODS: A total of 9 swine with early-reperfusion myocardial infarction were mapped with the QDOT microcatheter. HR-LGE-CMR (0.3-mm slices) were merged with EAVM. At each EAVM point, the underlying VM in multisize transmural cylinders and spheres was quantified from ex vivo CMR and related to unipolar and bipolar voltages recorded from conventional and microelectrodes. RESULTS: In each swine, 220 mapping points (Q1, Q3: 216, 260 mapping points) were collected. Infarcts were heterogeneous and nontransmural. Unipolar and bipolar voltage increased with VM volumes from >175 mm3 up to >525 mm3 (equivalent to a 5-mm radius cylinder with height >6.69 mm). VM volumes in subendocardial cylinders with 1- or 3-mm depth correlated poorly with all voltages. Unipolar voltages recorded with conventional and microelectrodes were similar (difference 0.17 ± 2.66 mV) and correlated best to VM within a sphere of radius 10 and 8 mm, respectively. Distance-weighting did not improve the correlation. CONCLUSIONS: Voltage increases with transmural volume of VM but correlates poorly with small amounts of VM, which limits EAVM in defining heterogeneous scar. Microelectrodes cannot distinguish thin from thick areas of subendocardial VM. The field-of-view for unipolar recordings for microelectrodes and conventional electrodes appears to be 8 to 10 mm, respectively, and unexpectedly similar.


Assuntos
Infarto do Miocárdio , Animais , Suínos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Gadolínio , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Microeletrodos , Eletrodos , Miocárdio/patologia , Meios de Contraste
8.
Cardiol Ther ; 13(1): 103-116, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38062285

RESUMO

INTRODUCTION: The use of serial coronary computed tomography angiography (CCTA) allows for the early assessment of coronary plaque progression, a crucial factor in averting major adverse cardiac events (MACEs). Traditionally, serial CCTA is assessed using anatomical landmarks to match baseline and follow-up scans. Recently, a tool has been developed that allows for the automatic quantification of local plaque thickness differences in serial CCTA utilizing plaque contour delineation. The aim of this study was to determine thresholds of plaque thickness differences that define whether there is plaque progression and/or regression. These thresholds depend on the contrast-to-noise ratio (CNR). METHODS: Plaque thickness differences between two scans acquired at the same moment in time should always be zero. The negative and positive differences in plaque contour delineation in these scans were used along with the CNR in order to create calibration graphs on which a linear regression analysis was performed. This analysis was conducted on a cohort of 50 patients referred for a CCTA due to chest complaints. A total of 300 coronary vessels were analyzed. First, plaque contours were semi-automatically determined for all major epicardial coronary vessels. Second, manual drawings of seven regions of interest (ROIs) per scan were used to quantify the scan quality based on the CNR for each vessel. RESULTS: A linear regression analysis was performed on the CNR and negative and positive plaque contour delineation differences. Accounting for the standard error of the estimate, the linear regression analysis revealed that above 1.009 - 0.002 × CNR there is an increase in plaque thickness (progression), and below - 1.638 + 0.012 × CNR there is a decrease in plaque thickness (regression). CONCLUSION: This study demonstrates the feasibility of developing vessel-specific, quality-based thresholds for visualizing local plaque thickness differences evaluated by serial CCTA. These thresholds have the potential to facilitate the early detection of atherosclerosis progression.

9.
Eur Radiol ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38001250

RESUMO

OBJECTIVES: Carotid atherosclerosis plays an essential role in the occurrence of ischemic stroke. This study aimed to investigate whether a larger burden of napkin-ring sign (NRS) plaques on cervicocerebral computed tomography angiography (CTA) increased the risk of acute ischemic stroke (AIS). METHODS: This retrospective, single-center, cross-sectional study enrolled patients with NRS plaques identified in the subclavian arteries, brachiocephalic trunk, carotid arterial system, and vertebrobasilar circulation on contrast-enhanced cervicocerebral CTA. Patients were divided into AIS and non-AIS groups based on imaging within 12 h of symptom onset. Univariate and multivariate logistic regression analyses were performed to determine the risk factor of AIS occurrence. RESULTS: A total of 202 patients (66.72 years ± 8.97, 157 men) were evaluated. Plaques with NRS in each subject of the AIS group (N = 98) were significantly more prevalent than that in the control group (N = 104) (1.96 ± 1.17 vs 1.41 ± 0.62). In the AIS group, there were substantially more NRS plaques on the ipsilateral side than contralateral side (1.55 ± 0.90 vs. 0.41 ± 0.66). NRS located on the ipsilateral side of the AIS showed an area under the receiver curve (AUC) of 0.86 to identify ischemic stroke. NRS plaque amounts were an independent risk factor for AIS occurrence (odds ratio, 1.86) after adjusting for other factors. CONCLUSIONS: Increased incidence of napkin-ring sign plaques on cervicocerebral CTA was positively associated with AIS occurrence, which could aid in detecting asymptomatic atherosclerotic patients at high risk of AIS in routine screening or emergency settings. CLINICAL RELEVANCE STATEMENT: Napkin-ring sign plaque provides an important imaging target for estimating acute ischemic stroke risk and identifying high-risk patients in routine screening or emergency settings, so that timely anti-atherosclerotic therapy can be used for prevention. KEY POINTS: • This cross-sectional study investigated the association between high-risk carotid artery plaques and acute ischemic stroke. • Increased incidence of napkin-ring sign plaques on cervicocerebral computed tomography angiography is positively associated with acute ischemic stroke occurrence. • Napkin-ring signs help identify risky patients prone to acute ischemic stroke to facilitate prevention.

10.
Cerebrovasc Dis ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37984345

RESUMO

INTRODUCTION: Carotid atherosclerotic intraplaque hemorrhage (IPH) predicts stroke. Patients with a history of stroke are treated with antiplatelet agents to prevent secondary cardiovascular events. A positive association between previous antiplatelet use and IPH was reported in a cross-sectional analysis. We investigated changes in IPH over two years in patients who recently started versus those with continued antiplatelet use. METHODS: In the Plaque at Risk (PARISK) study, symptomatic patients with <70% ipsilateral carotid stenosis underwent carotid plaque MRI at baseline and after two years to determine IPH presence and volume. Participants were categorized into new users (starting antiplatelet therapy following the index event) and continued users (previous use of antiplatelet therapy before the index event). The association between previous antiplatelet therapy and the presence of IPH at baseline MRI was investigated using multivariable logistic regression analysis. IPH volume change over a period of two years, defined as the difference in volume between follow-up and baseline, was investigated in each group with a Wilcoxon signed-rank test. The IPH volume change was categorized as progression, regression, or no change. Using multivariable logistic regression, we investigated the association between new antiplatelet use and 1) newly developed ipsilateral or contralateral IPH and 2) IPH volume progression. RESULTS: A total of 108 patients underwent carotid MRI at baseline and follow-up. At baseline, previous antiplatelet therapy was associated with any IPH (OR=5.6, 95% CI: 1.3-23.1; p=0.02). Ipsilateral IPH volume did not change significantly during the two years in patients who continued receiving antiplatelet agents (86.4 mm3 [18.2-235.9] vs. 59.3 mm3 [11.4-260.3]; p=0.6) nor in the new antiplatelet users (n=31) (61.5 mm3 [0.0-166.9] vs. 27.7 mm3 [9.5-106.4]; p=0.4). Similar results of a nonsignificant change in contralateral IPH volume during those two years were observed in both groups (p>0.05). No significant associations were found between new antiplatelet use and newly developed IPH at two years (odds ratio (OR)=1.0, 95% CI:0.1-7.4) or the progression of IPH (ipsilateral: OR=2.4, 95% CI:0.3-19.1; contralateral: OR=0.3, 95% CI:0.01-8.5). CONCLUSION: Although the baseline association between IPH and previous antiplatelet therapy was confirmed in this larger cohort, the new onset of antiplatelet therapy after TIA/stroke was not associated with newly developed IPH or progression of IPH volume over the subsequent two years.

11.
Front Cardiovasc Med ; 10: 1167500, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37904806

RESUMO

Introduction: As the life expectancy of children with congenital heart disease (CHD) is rapidly increasing and the adult population with CHD is growing, there is an unmet need to improve clinical workflow and efficiency of analysis. Cardiovascular magnetic resonance (CMR) is a noninvasive imaging modality for monitoring patients with CHD. CMR exam is based on multiple breath-hold 2-dimensional (2D) cine acquisitions that should be precisely prescribed and is expert and institution dependent. Moreover, 2D cine images have relatively thick slices, which does not allow for isotropic delineation of ventricular structures. Thus, development of an isotropic 3D cine acquisition and automatic segmentation method is worthwhile to make CMR workflow straightforward and efficient, as the present work aims to establish. Methods: Ninety-nine patients with many types of CHD were imaged using a non-angulated 3D cine CMR sequence covering the whole-heart and great vessels. Automatic supervised and semi-supervised deep-learning-based methods were developed for whole-heart segmentation of 3D cine images to separately delineate the cardiac structures, including both atria, both ventricles, aorta, pulmonary arteries, and superior and inferior vena cavae. The segmentation results derived from the two methods were compared with the manual segmentation in terms of Dice score, a degree of overlap agreement, and atrial and ventricular volume measurements. Results: The semi-supervised method resulted in a better overlap agreement with the manual segmentation than the supervised method for all 8 structures (Dice score 83.23 ± 16.76% vs. 77.98 ± 19.64%; P-value ≤0.001). The mean difference error in atrial and ventricular volumetric measurements between manual segmentation and semi-supervised method was lower (bias ≤ 5.2 ml) than the supervised method (bias ≤ 10.1 ml). Discussion: The proposed semi-supervised method is capable of cardiac segmentation and chamber volume quantification in a CHD population with wide anatomical variability. It accurately delineates the heart chambers and great vessels and can be used to accurately calculate ventricular and atrial volumes throughout the cardiac cycle. Such a segmentation method can reduce inter- and intra- observer variability and make CMR exams more standardized and efficient.

12.
Eur J Radiol ; 168: 111145, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37837923

RESUMO

PURPOSE: Carotid intraplaque hemorrhage (IPH) on MRI predicts stroke. Magnetization-prepared rapid acquisition gradient (MP-RAGE) is widely used to detect IPH. CE-MRA is used routinely to assess stenosis. Initial studies indicated that IPH can be identified on mask images of CE-MRA, while Time-of-Flight (TOF) images were reported to have high specificity but lower sensitivity. We investigated the diagnostic accuracy of detecting IPH on mask images of CE-MRA and TOF. METHODS: Thirty-six patients with ≥ 50% stenosis enrolled in the ongoing 2nd European Carotid Surgery Trial underwent carotid MRI. A 5-point quality score was used. Inter-observer agreement between two independent readers was determined. The sensitivity and specificity of IPH detection on mask MRA and TOF were calculated with MP-RAGE as a reference standard. RESULTS: Of the 36 patients included in the current analysis, 66/72 carotid arteries could be scored. The inter-observer agreements for identifying IPH on MP-RAGE, mask, and TOF were outstanding (κ: 0.93, 0.96, and 0.85). The image quality of mask (1.42 ± 0.66) and TOF (2.42 ± 0.66) was significantly lower than MP-RAGE (3.47 ± 0.61). When T1w images were used to delineate the outer carotid wall, very high specificities (>95%) of IPH detection on mask and TOF images were found, while the sensitivity was high for mask images (>81%) and poor for TOF (50-60%). Without these images, the specificity was still high (>97%), while the sensitivity reduced to 62-71%. CONCLUSION: Despite the lower image quality, routinely acquired mask images from CE-MRA, but not TOF, can be used as an alternative to MP-RAGE images to visualize IPH.


Assuntos
Estenose das Carótidas , Humanos , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Angiografia por Ressonância Magnética/métodos , Artérias Carótidas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hemorragia/diagnóstico por imagem
13.
J Cardiovasc Magn Reson ; 25(1): 50, 2023 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-37718441

RESUMO

BACKGROUND: Advances in four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) have allowed quantification of left ventricular (LV) and right ventricular (RV) blood flow. We aimed to (1) investigate age and sex differences of 4D flow CMR-derived LV and RV relative flow components and kinetic energy (KE) parameters indexed to end-diastolic volume (KEiEDV) in healthy subjects; and (2) assess the effects of age and sex on these parameters. METHODS: We performed 4D flow analysis in 163 healthy participants (42% female; mean age 43 ± 13 years) of a prospective registry study (NCT03217240) who were free of cardiovascular diseases. Relative flow components (direct flow, retained inflow, delayed ejection flow, residual volume) and multiple phasic KEiEDV (global, peak systolic, average systolic, average diastolic, peak E-wave, peak A-wave) for both LV and RV were analysed. RESULTS: Compared with men, women had lower median LV and RV residual volume, and LV peak and average systolic KEiEDV, and higher median values of RV direct flow, RV global KEiEDV, RV average diastolic KEiEDV, and RV peak E-wave KEiEDV. ANOVA analysis found there were no differences in flow components, peak and average systolic, average diastolic and global KEiEDV for both LV and RV across age groups. Peak A-wave KEiEDV increased significantly (r = 0.458 for LV and 0.341 for RV), whereas peak E-wave KEiEDV (r = - 0.355 for LV and - 0.318 for RV), and KEiEDV E/A ratio (r = - 0.475 for LV and - 0.504 for RV) decreased significantly, with age. CONCLUSION: These data using state-of-the-art 4D flow CMR show that biventricular flow components and kinetic energy parameters vary significantly by age and sex. Age and sex trends should be considered in the interpretation of quantitative measures of biventricular flow. Clinical trial registration  https://www. CLINICALTRIALS: gov . Unique identifier: NCT03217240.


Assuntos
Ventrículos do Coração , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Voluntários Saudáveis , Ventrículos do Coração/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Valores de Referência
14.
Eur Heart J Open ; 3(4): oead079, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37635784

RESUMO

Aims: Increased blood flow eccentricity in the aorta has been associated with aortic (AO) pathology, however, its association with exercise capacity has not been investigated. This study aimed to assess the relationships between flow eccentricity parameters derived from 2-dimensional (2D) phase-contrast (PC) cardiovascular magnetic resonance (CMR) imaging and aging and cardiopulmonary exercise test (CPET) in a cohort of healthy subjects. Methods and Results: One hundred and sixty-nine healthy subjects (age 44 ± 13 years, M/F: 96/73) free of cardiovascular disease were recruited in a prospective study (NCT03217240) and underwent CMR, including 2D PC at an orthogonal plane just above the sinotubular junction, and CPET (cycle ergometer) within one week. The following AO flow parameters were derived: AO forward and backward flow indexed to body surface area (FFi, BFi), average flow displacement during systole (FDsavg), late systole (FDlsavg), diastole (FDdavg), systolic retrograde flow (SRF), systolic flow reversal ratio (sFRR), and pulse wave velocity (PWV). Exercise capacity was assessed by peak oxygen uptake (PVO2) from CPET. The mean values of FDsavg, FDlsavg, FDdavg, SRF, sFRR, and PWV were 17 ± 6%, 19 ± 8%, 29 ± 7%, 4.4 ± 4.2 mL, 5.9 ± 5.1%, and 4.3 ± 1.6 m/s, respectively. They all increased with age (r = 0.623, 0.628, 0.353, 0.590, 0.649, 0.598, all P < 0.0001), and decreased with PVO2 (r = -0.302, -0.270, -0.253, -0.149, -0.219, -0.161, all P < 0.05). A stepwise multivariable linear regression analysis using left ventricular ejection fraction (LVEF), FFi, and FDsavg showed an area under the curve of 0.769 in differentiating healthy subjects with high-risk exercise capacity (PVO2 ≤ 14 mL/kg/min). Conclusion: AO flow haemodynamics change with aging and predict exercise capacity. Registration: NCT03217240.

15.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474977

RESUMO

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Assuntos
Sistema Cardiovascular , Humanos , Velocidade do Fluxo Sanguíneo , Valor Preditivo dos Testes , Coração , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
16.
Eur Respir J ; 62(2)2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37414419

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) is the gold standard technique to assess biventricular volumes and function, and is increasingly being considered as an end-point in clinical studies. Currently, with the exception of right ventricular (RV) stroke volume and RV end-diastolic volume, there is only limited data on minimally important differences (MIDs) reported for CMR metrics. Our study aimed to identify MIDs for CMR metrics based on US Food and Drug Administration recommendations for a clinical outcome measure that should reflect how a patient "feels, functions or survives". METHODS: Consecutive treatment-naïve patients with pulmonary arterial hypertension (PAH) between 2010 and 2022 who had two CMR scans (at baseline prior to treatment and 12 months following treatment) were identified from the ASPIRE registry. All patients were followed up for 1 additional year after the second scan. For both scans, cardiac measurements were obtained from a validated fully automated segmentation tool. The MID in CMR metrics was determined using two distribution-based (0.5sd and minimal detectable change) and two anchor-based (change difference and generalised linear model regression) methods benchmarked to how a patient "feels" (emPHasis-10 quality of life questionnaire), "functions" (incremental shuttle walk test) or "survives" for 1-year mortality to changes in CMR measurements. RESULTS: 254 patients with PAH were included (mean±sd age 53±16 years, 79% female and 66% categorised as intermediate risk based on the 2022 European Society of Cardiology/European Respiratory Society risk score). We identified a 5% absolute increase in RV ejection fraction and a 17 mL decrease in RV end-diastolic or end-systolic volumes as the MIDs for improvement. Conversely, a 5% decrease in RV ejection fraction and a 10 mL increase in RV volumes were associated with worsening. CONCLUSIONS: This study establishes clinically relevant CMR MIDs for how a patient "feels, functions or survives" in response to PAH treatment. These findings provide further support for the use of CMR as a clinically relevant clinical outcome measure and will aid trial size calculations for studies using CMR.


Plain language summaryPulmonary arterial hypertension (PAH) is a disease of the vessels of the lung that causes their narrowing and stiffening. As a result, the heart pumping blood into these diseased lung vessels has to work harder and eventually gets worn out. PAH can affect patients' ability to function in daily activities and impact their quality of life. It also reduces their life expectancy dramatically. Patients are, therefore, often monitored and undergo several investigations to adapt treatment according to their situation. These investigations include a survey of how a patient feels (the emPHasis-10 questionnaire), functions (walking test) and how well the heart is coping with the disease (MRI of the heart). Until now, it is unclear how changes on MRI of the heart reflect changes in how a patient feels and functions. Our study identified patients that had the emPHasis-10 questionnaire, walking test and MRI of the heart at both the time of PAH diagnosis and one year later. This allowed us to compare how the changes in the different tests relate to each other. And because previous research identified thresholds for important changes in the emPHasis-10 questionnaire and the walking tests, we were able to use these tests as a benchmark for changes in the MRI of the heart. Our study identified thresholds for change on heart MRI that might indicate whether a patient has improved or worsened. This finding might have implications for how patients are monitored in clinical practice and future research on PAH treatments.


Assuntos
Hipertensão Arterial Pulmonar , Disfunção Ventricular Direita , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Hipertensão Arterial Pulmonar/diagnóstico por imagem , Qualidade de Vida , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Hipertensão Pulmonar Primária Familiar , Função Ventricular Direita , Valor Preditivo dos Testes
17.
Abdom Radiol (NY) ; 48(10): 3072-3078, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37378865

RESUMO

BACKGROUND: MRI relaxometry mapping and proton density fat fraction (PDFF) have been proposed for the evaluation of hepatic fibrosis. However, sex-specific relationships of age and body fat with these MRI parameters have not been studied in detail among adults without clinically manifest hepatic disease. We aimed to determine the sex-specific correlation of multiparametric MRI parameters with age and body fat and to evaluate their interplay associations. METHODS: 147 study participants (84 women, mean age 48±14 years, range 19-85 years) were prospectively enrolled. 3 T MRI including T1, T2 and T1ρ mapping and PDFF and R2* map were acquired. Visceral and subcutaneous fat were measured on the fat images from Dixon water-fat separation sequence. RESULTS: All MRI parameters demonstrated sex difference except for T1ρ. PDFF was more related to visceral than subcutaneous fat. Per 100 ml gain of visceral or subcutaneous fat is associated with 1 or 0.4% accretion of liver fat, respectively. PDFF and R2* were higher in men (both P = 0.01) while T1 and T2 were higher in women (both P < 0.01). R2* was positively but T1 and T2 were negatively associated with age in women (all P < 0.01), while T1ρ was positively related to age in men (P < 0.05). In all studies, R2* was positively and T1ρ was negatively associated with PDFF (both P <0.0001). CONCLUSION: Visceral fat plays an essential role in the elevated liver fat. When using MRI parametric measures for liver disease evaluation, the interplay between these parameters should be considered.


Assuntos
Hepatopatias , Fígado , Humanos , Feminino , Adulto , Masculino , Adulto Jovem , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Cirrose Hepática/patologia , Hepatopatias/patologia , Tecido Adiposo/patologia , Prótons
18.
IEEE J Biomed Health Inform ; 27(7): 3302-3313, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37067963

RESUMO

In recent years, several deep learning models have been proposed to accurately quantify and diagnose cardiac pathologies. These automated tools heavily rely on the accurate segmentation of cardiac structures in MRI images. However, segmentation of the right ventricle is challenging due to its highly complex shape and ill-defined borders. Hence, there is a need for new methods to handle such structure's geometrical and textural complexities, notably in the presence of pathologies such as Dilated Right Ventricle, Tricuspid Regurgitation, Arrhythmogenesis, Tetralogy of Fallot, and Inter-atrial Communication. The last MICCAI challenge on right ventricle segmentation was held in 2012 and included only 48 cases from a single clinical center. As part of the 12th Workshop on Statistical Atlases and Computational Models of the Heart (STACOM 2021), the M&Ms-2 challenge was organized to promote the interest of the research community around right ventricle segmentation in multi-disease, multi-view, and multi-center cardiac MRI. Three hundred sixty CMR cases, including short-axis and long-axis 4-chamber views, were collected from three Spanish hospitals using nine different scanners from three different vendors, and included a diverse set of right and left ventricle pathologies. The solutions provided by the participants show that nnU-Net achieved the best results overall. However, multi-view approaches were able to capture additional information, highlighting the need to integrate multiple cardiac diseases, views, scanners, and acquisition protocols to produce reliable automatic cardiac segmentation algorithms.


Assuntos
Aprendizado Profundo , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Átrios do Coração
19.
Med Sci (Basel) ; 11(1)2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36976528

RESUMO

Coronary artery disease (CAD) remains a leading cause of mortality and morbidity worldwide, and it is associated with considerable economic burden. In an ageing, multimorbid population, it has become increasingly important to develop reliable, consistent, low-risk, non-invasive means of diagnosing CAD. The evolution of multiple cardiac modalities in this field has addressed this dilemma to a large extent, not only in providing information regarding anatomical disease, as is the case with coronary computed tomography angiography (CCTA), but also in contributing critical details about functional assessment, for instance, using stress cardiac magnetic resonance (S-CMR). The field of artificial intelligence (AI) is developing at an astounding pace, especially in healthcare. In healthcare, key milestones have been achieved using AI and machine learning (ML) in various clinical settings, from smartwatches detecting arrhythmias to retinal image analysis and skin cancer prediction. In recent times, we have seen an emerging interest in developing AI-based technology in the field of cardiovascular imaging, as it is felt that ML methods have potential to overcome some limitations of current risk models by applying computer algorithms to large databases with multidimensional variables, thus enabling the inclusion of complex relationships to predict outcomes. In this paper, we review the current literature on the various applications of AI in the assessment of CAD, with a focus on multimodality imaging, followed by a discussion on future perspectives and critical challenges that this field is likely to encounter as it continues to evolve in cardiology.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Inteligência Artificial , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Imageamento por Ressonância Magnética
20.
Med Sci (Basel) ; 11(1)2023 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-36810480

RESUMO

There remains a debate whether the ventricular volume within prolapsing mitral valve (MV) leaflets should be included in the left ventricular (LV) end-systolic volume, and therefore factored in LV stroke volume (SV), in cardiac magnetic resonance (CMR) assessments. This study aims to compare LV volumes during end-systolic phases, with and without the inclusion of the volume of blood on the left atrial aspect of the atrioventricular groove but still within the MV prolapsing leaflets, against the reference LV SV by four-dimensional flow (4DF). A total of 15 patients with MV prolapse (MVP) were retrospectively enrolled in this study. We compared LV SV with (LV SVMVP) and without (LV SVstandard) MVP left ventricular doming volume, using 4D flow (LV SV4DF) as the reference value. Significant differences were observed when comparing LV SVstandard and LV SVMVP (p < 0.001), and between LV SVstandard and LV SV4DF (p = 0.02). The Intraclass Correlation Coefficient (ICC) test demonstrated good repeatability between LV SVMVP and LV SV4DF (ICC = 0.86, p < 0.001) but only moderate repeatability between LV SVstandard and LV SV4DF (ICC = 0.75, p < 0.01). Calculating LV SV by including the MVP left ventricular doming volume has a higher consistency with LV SV derived from the 4DF assessment. In conclusion, LV SV short-axis cine assessment incorporating MVP dooming volume can significantly improve the precision of LV SV assessment compared to the reference 4DF method. Hence, in cases with bi-leaflet MVP, we recommend factoring in MVP dooming into the left ventricular end-systolic volume to improve the accuracy and precision of quantifying mitral regurgitation.


Assuntos
Prolapso da Valva Mitral , Humanos , Prolapso da Valva Mitral/patologia , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...