Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
JAMA Netw Open ; 7(5): e2410819, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691356

RESUMO

Importance: In 2018, the first online adaptive magnetic resonance (MR)-guided radiotherapy (MRgRT) system using a 1.5-T MR-equipped linear accelerator (1.5-T MR-Linac) was clinically introduced. This system enables online adaptive radiotherapy, in which the radiation plan is adapted to size and shape changes of targets at each treatment session based on daily MR-visualized anatomy. Objective: To evaluate safety, tolerability, and technical feasibility of treatment with a 1.5-T MR-Linac, specifically focusing on the subset of patients treated with an online adaptive strategy (ie, the adapt-to-shape [ATS] approach). Design, Setting, and Participants: This cohort study included adults with solid tumors treated with a 1.5-T MR-Linac enrolled in Multi Outcome Evaluation for Radiation Therapy Using the MR-Linac (MOMENTUM), a large prospective international study of MRgRT between February 2019 and October 2021. Included were adults with solid tumors treated with a 1.5-T MR-Linac. Data were collected in Canada, Denmark, The Netherlands, United Kingdom, and the US. Data were analyzed in August 2023. Exposure: All patients underwent MRgRT using a 1.5-T MR-Linac. Radiation prescriptions were consistent with institutional standards of care. Main Outcomes and Measures: Patterns of care, tolerability, and technical feasibility (ie, treatment completed as planned). Acute high-grade radiotherapy-related toxic effects (ie, grade 3 or higher toxic effects according to Common Terminology Criteria for Adverse Events version 5.0) occurring within the first 3 months after treatment delivery. Results: In total, 1793 treatment courses (1772 patients) were included (median patient age, 69 years [range, 22-91 years]; 1384 male [77.2%]). Among 41 different treatment sites, common sites were prostate (745 [41.6%]), metastatic lymph nodes (233 [13.0%]), and brain (189 [10.5%]). ATS was used in 1050 courses (58.6%). MRgRT was completed as planned in 1720 treatment courses (95.9%). Patient withdrawal caused 5 patients (0.3%) to discontinue treatment. The incidence of radiotherapy-related grade 3 toxic effects was 1.4% (95% CI, 0.9%-2.0%) in the entire cohort and 0.4% (95% CI, 0.1%-1.0%) in the subset of patients treated with ATS. There were no radiotherapy-related grade 4 or 5 toxic effects. Conclusions and Relevance: In this cohort study of patients treated on a 1.5-T MR-Linac, radiotherapy was safe and well tolerated. Online adaptation of the radiation plan at each treatment session to account for anatomic variations was associated with a low risk of acute grade 3 toxic effects.


Assuntos
Neoplasias , Radioterapia Guiada por Imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Radioterapia Guiada por Imagem/efeitos adversos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Neoplasias/radioterapia , Neoplasias/diagnóstico por imagem , Adulto , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Estudos de Viabilidade , Estudos de Coortes , Idoso de 80 Anos ou mais
2.
Urol Oncol ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38724349

RESUMO

OBJECTIVE: To evaluate the real-world added value of androgen deprivation therapy (ADT) in addition to external beam radiotherapy (EBRT) in men with high-risk non-metastatic prostate cancer, in view of advances in radiotherapy and diagnostics. METHODS: All Dutch men diagnosed with high-risk non-metastatic prostate cancer (defined as: ≥cT2c-T3b N0M0, PSA ≥20-50 ng/ml, and/or Gleason score ≥8 (International Society of Urological Pathology [ISUP] grade ≥4)) from 2009 through 2019 and treated with EBRT with or without ADT were identified in the population-based Netherlands Cancer Registry. Propensity scores were used to match (1:1) men that received ADT to men that did not receive ADT. Subsequently, OS was compared. Analyses were also stratified by number of high-risk features, 1 (either ≥cT2c, PSA >20 ng/ml or Gleason score ≥8) versus ≥2 (out of ≥cT2c, PSA >20 ng/ml and Gleason score ≥8). RESULTS: A total of 14,773 men with high-risk non-metastatic prostate cancer were identified, 3,958 (27%) of which received EBRT alone. After matching, 3,427 men remained in both groups and baseline characteristics were well-balanced. After a median follow-up of 92 months, OS was better in men treated with EBRT and ADT compared to men treated with EBRT alone (10-year OS: 66.4% versus 61.8%; HR 0.88 [95%CI: 0.80-0.96]). There was no statistically significant difference in OS in the subgroup of men with only 1 high-risk feature (10-year OS 67.7% versus 64.9%; HR 0.95 [95%CI: 0.85-1.07]). CONCLUSIONS: In a contemporary cohort of men treated for high-risk non-metastatic prostate cancer with EBRT, an OS benefit of adding ADT was only observed in men with at least 2 high-risk features. These results suggest that improvements in diagnostics and treatment in recent decades have resulted in a stage shift of men benefiting from the addition of ADT to EBRT.

3.
Clin Transl Radiat Oncol ; 46: 100742, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38440792

RESUMO

Background and purpose: MRI-guided radiotherapy (MRIgRT) offers multiple potential advantages over CT-guidance. This study examines the potential clinical benefits of MRIgRT for men with localised prostate cancer, in the setting of moderately hypofractionated radiotherapy. We evaluate two-year toxicity outcomes, early biochemical response and patient-reported outcomes (PRO), using data obtained from a multicentre international registry study, for the first group of patients with prostate cancer who underwent treatment on a 1.5 T MR-Linac. Materials and methods: Patients who were enrolled within the MOMENTUM study and received radical treatment with 60 Gy in 20 fractions were identified. PSA levels and CTCAE version 5.0 toxicity data were measured at follow-up visits. Those patients who consented to PRO data collection also completed EQ-5D-5L, EORTC QLQ-C30 and EORTC QLQ-PR25 questionnaires. Results: Between November 2018 and June 2022, 146 patients who had MRIgRT for localised prostate cancer on the 1.5 T MR-Linac were eligible for this study. Grade 2 and worse gastro-intestinal (GI) toxicity was reported in 3 % of patients at three months whilst grade 2 and worse genitourinary (GU) toxicity was 7 % at three months. There was a significant decrease in the median PSA at 12 months. The results from both the EQ-5D-5L data and EORTC global health status scale indicate a decline in the quality of life (QoL) during the first six months. The mean change in score for the EORTC scale showed a decrease of 11.4 points, which is considered clinically important. QoL improved back to baseline by 24 months. Worsening of hormonal symptoms in the first six months was reported with a return to baseline by 24 months and sexual activity in all men worsened in the first three months and returned to baseline at 12 months. Conclusion: This study establishes the feasibility of online-MRIgRT for localised prostate on a 1.5 T MR-Linac with low rates of toxicity, similar to that published in the literature. However, the clinical benefits of MRIgRT over conventional radiotherapy in the setting of moderate hypofractionation is not evident. Further research will focus on the delivery of ultrahypofractionated regimens, where the potential advantages of MRIgRT for prostate cancer may become more discernible.

4.
Med Phys ; 51(4): 2367-2377, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38408022

RESUMO

BACKGROUND: Deep learning-based unsupervised image registration has recently been proposed, promising fast registration. However, it has yet to be adopted in the online adaptive magnetic resonance imaging-guided radiotherapy (MRgRT) workflow. PURPOSE: In this paper, we design an unsupervised, joint rigid, and deformable registration framework for contour propagation in MRgRT of prostate cancer. METHODS: Three-dimensional pelvic T2-weighted MRIs of 143 prostate cancer patients undergoing radiotherapy were collected and divided into 110, 13, and 20 patients for training, validation, and testing. We designed a framework using convolutional neural networks (CNNs) for rigid and deformable registration. We selected the deformable registration network architecture among U-Net, MS-D Net, and LapIRN and optimized the training strategy (end-to-end vs. sequential). The framework was compared against an iterative baseline registration. We evaluated registration accuracy (the Dice and Hausdorff distance of the prostate and bladder contours), structural similarity index, and folding percentage to compare the methods. We also evaluated the framework's robustness to rigid and elastic deformations and bias field perturbations. RESULTS: The end-to-end trained framework comprising LapIRN for the deformable component achieved the best median (interquartile range) prostate and bladder Dice of 0.89 (0.85-0.91) and 0.86 (0.80-0.91), respectively. This accuracy was comparable to the iterative baseline registration: prostate and bladder Dice of 0.91 (0.88-0.93) and 0.86 (0.80-0.92). The best models complete rigid and deformable registration in 0.002 (0.0005) and 0.74 (0.43) s (Nvidia Tesla V100-PCIe 32 GB GPU), respectively. We found that the models are robust to translations up to 52 mm, rotations up to 15 ∘ $^\circ$ , elastic deformations up to 40 mm, and bias fields. CONCLUSIONS: Our proposed unsupervised, deep learning-based registration framework can perform rigid and deformable registration in less than a second with contour propagation accuracy comparable with iterative registration.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Próstata/patologia , Pelve , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
5.
Eur Radiol Exp ; 8(1): 1, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38165522

RESUMO

BACKGROUND: Pelvic morphological parameters on magnetic resonance imaging (MRI), such as the membranous urethral length (MUL), can predict urinary incontinence after radical prostatectomy but are prone to interobserver disagreement. Our objective was to improve interobserver agreement among radiologists in measuring pelvic parameters using deep learning (DL)-based segmentation of pelvic structures on MRI scans. METHODS: Preoperative MRI was collected from 167 prostate cancer patients undergoing radical prostatectomy within our regional multicentric cohort. Two DL networks (nnU-Net) were trained on coronal and sagittal scans and evaluated on a test cohort using an 80/20% train-test split. Pelvic parameters were manually measured by three abdominal radiologists on raw MRI images and with the use of DL-generated segmentations. Automated measurements were also performed for the pelvic parameters. Interobserver agreement was evaluated using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. RESULTS: The DL models achieved median Dice similarity coefficient (DSC) values of 0.85-0.97 for coronal structures and 0.87-0.98 for sagittal structures. When radiologists used DL-generated segmentations of pelvic structures, the interobserver agreement for sagittal MUL improved from 0.64 (95% confidence interval 0.28-0.83) to 0.91 (95% CI 0.84-0.95). Furthermore, there was an increase in ICC values for the obturator internus muscle from 0.74 (95% CI 0.42-0.87) to 0.86 (95% CI 0.75-0.92) and for the levator ani muscle from 0.40 (95% CI 0.05-0.66) to 0.61 (95% CI 0.31-0.78). CONCLUSIONS: DL-based automated segmentation of pelvic structures improved interobserver agreement in measuring pelvic parameters on preoperative MRI scans. RELEVANCE STATEMENT: The implementation of deep learning segmentations allows for more consistent measurements of pelvic parameters by radiologists. Standardized measurements are crucial for incorporating these parameters into urinary continence prediction models. KEY POINTS: • DL-generated segmentations improve interobserver agreement for pelvic measurements among radiologists. • Membranous urethral length measurement improved from substantial to almost perfect agreement. • Artificial intelligence enhances objective pelvic parameter assessment for continence prediction models.


Assuntos
Neoplasias da Próstata , Incontinência Urinária , Masculino , Humanos , Inteligência Artificial , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Prostatectomia , Incontinência Urinária/diagnóstico por imagem
6.
Int J Radiat Oncol Biol Phys ; 118(2): 378-389, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37633499

RESUMO

PURPOSE: The use of magnetic resonance imaging (MRI) in radiotherapy planning is becoming more widespread, particularly with the emergence of MRI-guided radiotherapy systems. Existing guidelines for defining the prostate bed clinical target volume (CTV) show considerable heterogeneity. This study aimed to establish baseline interobserver variability (IOV) for prostate bed CTV contouring on MRI, develop international consensus guidelines, and evaluate its effect on IOV. METHODS AND MATERIALS: Participants delineated the CTV on 3 MRI scans, obtained from the Elekta Unity MR-Linac, as per their normal practice. Radiation oncologist contours were visually examined for discrepancies, and interobserver comparisons were evaluated against simultaneous truth and performance level estimation (STAPLE) contours using overlap metrics (Dice similarity coefficient and Cohen's kappa), distance metrics (mean distance to agreement and Hausdorff distance), and volume measurements. A literature review of postradical prostatectomy local recurrence patterns was performed and presented alongside IOV results to the participants. Consensus guidelines were collectively constructed, and IOV assessment was repeated using these guidelines. RESULTS: Sixteen radiation oncologists' contours were included in the final analysis. Visual evaluation demonstrated significant differences in the superior, inferior, and anterior borders. Baseline IOV assessment indicated moderate agreement for the overlap metrics while volume and distance metrics demonstrated greater variability. Consensus for optimal prostate bed CTV boundaries was established during a virtual meeting. After guideline development, a decrease in IOV was observed. The maximum volume ratio decreased from 4.7 to 3.1 and volume coefficient of variation reduced from 40% to 34%. The mean Dice similarity coefficient rose from 0.72 to 0.75 and the mean distance to agreement decreased from 3.63 to 2.95 mm. CONCLUSIONS: Interobserver variability in prostate bed contouring exists among international genitourinary experts, although this is lower than previously reported. Consensus guidelines for MRI-based prostate bed contouring have been developed, and this has resulted in an improvement in contouring concordance. However, IOV persists and strategies such as an education program, development of a contouring atlas, and further refinement of the guidelines may lead to additional improvements.


Assuntos
Radioterapia Guiada por Imagem , Masculino , Humanos , Radioterapia Guiada por Imagem/métodos , Próstata/diagnóstico por imagem , Variações Dependentes do Observador , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
8.
Cancers (Basel) ; 15(22)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38001712

RESUMO

Adequate detection of the histopathological extraprostatic extension (EPE) of prostate cancer (PCa) remains a challenge using conventional radiomics on 3 Tesla multiparametric magnetic resonance imaging (3T mpMRI). This study focuses on the assessment of artificial intelligence (AI)-driven models with innovative MRI radiomics in predicting EPE of prostate cancer (PCa) at a lesion-specific level. With a dataset encompassing 994 lesions from 794 PCa patients who underwent robot-assisted radical prostatectomy (RARP) at two Dutch hospitals, the study establishes and validates three classification models. The models were validated on an internal validation cohort of 162 lesions and an external validation cohort of 189 lesions in terms of discrimination, calibration, net benefit, and comparison to radiology reporting. Notably, the achieved AUCs ranged from 0.86 to 0.91 at the lesion-specific level, demonstrating the superior accuracy of the random forest model over conventional radiological reporting. At the external test cohort, the random forest model was the best-calibrated model and demonstrated a significantly higher accuracy compared to radiological reporting (83% vs. 67%, p = 0.02). In conclusion, an AI-powered model that includes both existing and novel MRI radiomics improves the detection of lesion-specific EPE in prostate cancer.

9.
Phys Imaging Radiat Oncol ; 26: 100453, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37312973

RESUMO

Background and purpose: Manual contouring of neurovascular structures on prostate magnetic resonance imaging (MRI) is labor-intensive and prone to considerable interrater disagreement. Our aim is to contour neurovascular structures automatically on prostate MRI by deep learning (DL) to improve workflow and interrater agreement. Materials and methods: Segmentation of neurovascular structures was performed on pre-treatment 3.0 T MRI data of 131 prostate cancer patients (training [n = 105] and testing [n = 26]). The neurovascular structures include the penile bulb (PB), corpora cavernosa (CCs), internal pudendal arteries (IPAs), and neurovascular bundles (NVBs). Two DL networks, nnU-Net and DeepMedic, were trained for auto-contouring on prostate MRI and evaluated using volumetric Dice similarity coefficient (DSC), mean surface distances (MSD), Hausdorff distances, and surface DSC. Three radiation oncologists evaluated the DL-generated contours and performed corrections when necessary. Interrater agreement was assessed and the time required for manual correction was recorded. Results: nnU-Net achieved a median DSC of 0.92 (IQR: 0.90-0.93) for the PB, 0.90 (IQR: 0.86-0.92) for the CCs, 0.79 (IQR: 0.77-0.83) for the IPAs, and 0.77 (IQR: 0.72-0.81) for the NVBs, which outperformed DeepMedic for each structure (p < 0.03). nnU-Net showed a median MSD of 0.24 mm for the IPAs and 0.71 mm for the NVBs. The median interrater DSC ranged from 0.93 to 1.00, with the majority of cases (68.9%) requiring manual correction times under two minutes. Conclusions: DL enables reliable auto-contouring of neurovascular structures on pre-treatment MRI data, easing the clinical workflow in neurovascular-sparing MR-guided radiotherapy.

10.
Radiother Oncol ; 185: 109713, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37178932

RESUMO

BACKGROUND AND PURPOSE: The hypo-FLAME trial showed that once-weekly (QW) focal boosted prostate stereotactic body radiotherapy (SBRT) is associated with acceptable acute genitourinary (GU) and gastrointestinal (GI) toxicity. Currently, we investigated the safety of reducing the overall treatment time (OTT) of focal boosted prostate SBRT from 29 to 15 days. MATERIAL AND METHODS: Patients with intermediate- and high-risk prostate cancer were treated with SBRT delivering 35 Gy in 5 fractions to the whole prostate gland with an iso-toxic boost up to 50 Gy to the intraprostatic lesion(s) in a semi-weekly (BIW) schedule. The primary endpoint was radiation-induced acute toxicity (CTCAE v5.0). Changes in quality of life (QoL) were examined in terms of proportions achieving a minimal clinically important change (MCIC). Finally, acute toxicity and QoL scores of the BIW schedule were compared with the results of the prior QW hypo-FLAME schedule (n = 100). RESULTS: Between August 2020 and February 2022, 124 patients were enrolled and treated BIW. No grade ≥3 GU or GI toxicity was observed. The 90-days cumulative incidence of grade 2 GU and GI toxicity rates were 47.5% and 7.4%, respectively. Patients treated QW scored significant less grade 2 GU toxicity (34.0%, p = 0.01). No significant differences in acute GI toxicity were observed. Furthermore, patients treated QW had a superior acute bowel and urinary QoL. CONCLUSION: Semi-weekly prostate SBRT with iso-toxic focal boosting is associated with acceptable acute GU and GI toxicity. Based on the comparison between the QW and BIW schedule, patients should be counselled regarding the short-term advantages of a more protracted schedule. Registration number ClinicalTrials.gov: NCT04045717.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Lesões por Radiação , Radiocirurgia , Masculino , Humanos , Próstata , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Qualidade de Vida , Sistema Urogenital , Gastroenteropatias/etiologia , Lesões por Radiação/etiologia
11.
BMC Cancer ; 23(1): 268, 2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-36959540

RESUMO

BACKGROUND: Prostate cancer patients with locoregional lymph node disease at diagnosis (N1M0) still have a limited prognosis despite the improvements provided by aggressive curative intent multimodal locoregional external beam radiation therapy (EBRT) with systemic androgen deprivation therapy (ADT). Although some patients can be cured and the majority of patients have a long survival, the 5-year biochemical failure rate is currently 29-47%. [177Lu]Lu-PSMA-617 has shown impressive clinical and biochemical responses with low toxicity in salvage setting in metastatic castration-resistant prostate cancer. This study aims to explore the combination of standard EBRT and ADT complemented with a single administration of [177Lu]Lu-PSMA-617 in curative intent treatment for N1M0 prostate cancer. Hypothetically, this combined approach will enhance EBRT to better control macroscopic tumour localizations, and treat undetected microscopic disease locations inside and outside EBRT fields. METHODS: The PROQURE-I study is a multicenter prospective phase I study investigating standard of care treatment (7 weeks EBRT and 3 years ADT) complemented with one concurrent cycle (three, six, or nine GBq) of systemic [177Lu]Lu-PSMA-617 administered in week two of EBRT. A maximum of 18 patients with PSMA-positive N1M0 prostate cancer will be included. The tolerability of adding [177Lu]Lu-PSMA-617 will be evaluated using a Bayesian Optimal Interval (BOIN) dose-escalation design. The primary objective is to determine the maximum tolerated dose (MTD) of a single cycle [177Lu]Lu-PSMA-617 when given concurrent with EBRT + ADT, defined as the occurrence of Common Terminology Criteria for Adverse Events (CTCAE) v 5.0 grade three or higher acute toxicity. Secondary objectives include: late toxicity at 6 months, dosimetric assessment, preliminary biochemical efficacy at 6 months, quality of life questionnaires, and pharmacokinetic modelling of [177Lu]Lu-PSMA-617. DISCUSSION: This is the first prospective study to combine EBRT and ADT with [177Lu]Lu-PSMA-617 in treatment naïve men with N1M0 prostate cancer, and thereby explores the novel application of [177Lu]Lu-PSMA-617 in curative intent treatment. It is considered likely that this study will confirm tolerability as the combined toxicity of these treatments is expected to be limited. Increased efficacy is considered likely since both individual treatments have proven high anti-tumour effect as mono-treatments. TRIAL REGISTRATION: ClinicalTrials, NCT05162573 . Registered 7 October 2021.


Assuntos
Neoplasias de Próstata Resistentes à Castração , Qualidade de Vida , Humanos , Masculino , Antagonistas de Androgênios/uso terapêutico , Teorema de Bayes , Dipeptídeos/efeitos adversos , Compostos Heterocíclicos com 1 Anel/efeitos adversos , Estudos Prospectivos , Antígeno Prostático Específico , Neoplasias de Próstata Resistentes à Castração/tratamento farmacológico , Neoplasias de Próstata Resistentes à Castração/radioterapia , Resultado do Tratamento
13.
BJUI Compass ; 4(2): 214-222, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36816141

RESUMO

Objectives: To assess the patient preferences and utility scores for the different conventional and innovative treatment modalities for localised prostate cancer (PCa). Subjects and Methods: Patients treated for localised PCa and healthy volunteers were invited to fill out a treatment-outcome scenario questionnaire. Participants ranked six different treatments for localised PCa from most to least favourable, prior to information. In a next step, treatment procedures, toxicity, risk of biochemical recurrence and follow-up regimen were comprehensibly described for each of the six treatments (i.e. treatment-outcome scenarios), after which patients re-ranked the six treatments. Additionally, participants gave a visual analogue scale (VAS) and time trade-off (TTO) score for each scenario. Differences between utility scores were tested by Friedman tests with post hoc Wilcoxon signed-rank tests. Results: Eighty patients and twenty-nine healthy volunteers were included in the study. Before receiving treatment-outcome scenario information, participants ranked magnetic resonance-guided adaptive radiotherapy most often as their first choice (35%). After treatment information was received, active surveillance was most often ranked as the first choice (41%). Utility scores were significantly different between the six treatment-outcome scenarios, and active surveillance, non- and minimal-invasive treatments received higher scores. Conclusions: Active surveillance and non-invasive treatment for localised PCa were the most preferred options by PCa patients and healthy volunteers and received among the highest utility scores. Treatment preferences change after treatment information is received.

14.
Radiother Oncol ; 180: 109495, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36708924

RESUMO

BACKGROUND AND PURPOSE: Radiorecurrent prostate cancer is often confined to the prostate, predominantly near the index lesion. The purpose of this study was to look at recurrence characteristics in patients treated with focal salvage high dose-rate (HDR) brachytherapy. MATERIALS AND METHODS: Patients treated with MRI-guided HDR brachytherapy, with a single fraction of 19 Gy from July 2013 to October 2021 as focal salvage treatment, were prospectively included in the current study. Imaging data were collected regarding the occurrence of local, regional and distant recurrences, including location of local recurrences (LR) in relation to the HDR radiotherapy field. RESULTS: One hundred seventy-five patients were included after focal salvage HDR brachytherapy (median follow-up 36 months (IQR 23-50)). Three-years biochemical recurrence-free survival, LR-free survival, in-field LR-free survival, out-of-field LR-free survival, any-recurrence-free survival and ADT-free survival were 43% (95%CI 34%-52%), 51% (41%-61%), 70% (61%-80%), 92% (88%-97%), 42% (32%-52%) and 86% (80%-92%), respectively. Larger GTV-size and shorter PSA doubling time were associated with in-field LR in multivariable analysis. CONCLUSION: After focal salvage HDR brachytherapy with a dose of 1x19 Gy for local prostate cancer recurrence, subsequent recurrences are mostly local and in-field.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Braquiterapia/métodos , Dosagem Radioterapêutica , Recidiva Local de Neoplasia/patologia , Neoplasias da Próstata/patologia , Antígeno Prostático Específico , Terapia de Salvação/métodos
15.
Pract Radiat Oncol ; 13(3): e261-e269, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36462619

RESUMO

PURPOSE: Magnetic resonance (MR)-guided radiation therapy (MRgRT) is a new technique for treatment of localized prostate cancer (PCa). We report the 12-month outcomes for the first PCa patients treated within an international consortium (the MOMENTUM study) on a 1.5T MR-Linac system with ultrahypofractionated radiation therapy. METHODS AND MATERIALS: Patients treated with 5 × 7.25 Gy were identified. Prostate specific antigen-level, physician-reported toxicity (Common Terminology Criteria for Adverse Events [CTCAE]), and patient-reported outcomes (Quality of Life Questionnaire PR25 and Quality of Life Questionnaire C30 questionnaires) were recorded at baseline and at 3, 6, and 12 months of follow-up (FU). Pairwise comparative statistics were conducted to compare outcomes between baseline and FU. RESULTS: The study included 425 patients with localized PCa (11.4% low, 82.0% intermediate, and 6.6% high-risk), and 365, 313, and 186 patients reached 3-, 6-, and 12-months FU, respectively. Median prostate specific antigen level declined significantly to 1.2 ng/mL and 0.1 ng/mL at 12 months FU for the nonandrogen deprivation therapy (ADT) and ADT group, respectively. The peak of genitourinary and gastrointestinal CTCAE toxicity was reported at 3 months FU, with 18.7% and 1.7% grade ≥2, respectively. The QLQ-PR25 questionnaire outcomes showed significant deterioration in urinary domain score at all FU moments, from 8.3 (interquartile range [IQR], 4.1-16.6) at baseline to 12.4 (IQR, 8.3-24.8; P = .005) at 3 months, 12.4 (IQR, 8.3-20.8; P = .018;) at 6 months, and 12.4 (IQR, 8.3-20.8; P = .001) at 12 months. For the non-ADT group, physician- and patient-reported erectile function worsened significantly between baseline and 12 months FU. CONCLUSIONS: Ultrahypofractionated MR-guided radiation therapy for localized PCa using a 1.5T MR-Linac is effective and safe. The peak of CTCAE genitourinary and gastrointestinal toxicity was reported at 3 months FU. Furthermore, for patients without ADT, a significant increase in CTCAE erectile dysfunction was reported at 12 months FU. These data are useful for educating patients on expected outcomes and informing study design of future comparative-effectiveness studies.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Masculino , Humanos , Antígeno Prostático Específico , Qualidade de Vida , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Espectroscopia de Ressonância Magnética , Sistema de Registros
17.
Ned Tijdschr Geneeskd ; 1662022 10 05.
Artigo em Holandês | MEDLINE | ID: mdl-36300470

RESUMO

MR-guided brachytherapy offers a focal salvage treatment for the local recurrence in case of isolated locally recurrent prostate cancer in the prostate and/or seminal vesicles after primary radiotherapy. By focusing on only the local recurrence instead of the whole prostate, chances of additional toxicity of the bladder, urethra and rectum can be minimized. In almost all patients, the treatment leads to a good initial treatment response that persists in about half of patients, while others will develop progressive disease later on. For selecting suitable patients, factors such as preexistent urinary- and bowel complaints, localization and size of the recurrence, PSA doubling time and time between primary radiotherapy and development of the recurrence are relevant. MR-guided brachytherapy can provide a suitable salvage strategy, with the aims of deferring androgen deprivation therapy and a chance of cure.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Antígeno Prostático Específico , Antagonistas de Androgênios , Androgênios , Recidiva Local de Neoplasia/radioterapia , Imageamento por Ressonância Magnética
18.
Radiother Oncol ; 176: 25-30, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36113777

RESUMO

BACKGROUND: Intrafraction motion during radiotherapy limits margin reduction and dose escalation. Magnetic resonance (MR)-guided linear accelerators (MR-Linac) have emphasised this issue by enabling intrafraction imaging. We present and clinically apply a new workflow to counteract systematic intrafraction motion during MR-guided stereotactic body radiotherapy (SBRT). MATERIALS AND METHODS: With the sub-fractionation workflow, the daily dose is delivered in multiple sequential parts (sub-fractions), each adapted to the latest anatomy. As each sub-fractionation treatment plan complies with the dose constraints, no online dose accumulation is required. Imaging and treatment planning are executed in parallel with dose delivery to minimise dead time, enabling an efficient workflow. The workflow was implemented on a 1.5 T MR-Linac and applied in 15 prostate cancer (PCa) patients treated with 5 × 7.25 Gy in two sub-fractions of 3.625 Gy (10 × 3.625 Gy in total). Intrafraction clinical target volume (CTV) motion was determined and compared to a workflow with single-plan delivery. Furthermore, required planning target volume (PTV) margins were determined. RESULTS: Average on-table time was 42.7 min. Except for two fractions, all fractions were delivered within 60 min. Average intrafraction 3D CTV displacement (±standard deviation) was 1.1 mm (± 0.7) with the sub-fractionation workflow, whereas this was up to 3.5 mm (± 2.4) without sub-fractionation. Calculated PTV margins required with sub-fractionation were 1.0 mm (left-right), 2.4 mm (cranial-caudal), and 2.6 mm (anterior-posterior). CONCLUSION: Feasibility of the sub-fractionation workflow was demonstrated in 15 PCa patients treated with two sub-fractions on a 1.5 T MR-Linac. The workflow allows for significant PTV margin reduction in these patients by reducing systematic intrafraction motion during SBRT.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Masculino , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Próstata , Fluxo de Trabalho , Aceleradores de Partículas , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Espectroscopia de Ressonância Magnética
19.
Artigo em Inglês | MEDLINE | ID: mdl-36090011

RESUMO

Background and purpose: Online adaptive MR-guided treatment planning workflows facilitate daily contour adaptation to the actual anatomy. Allocating contour adaptation to radiation therapists (RTTs) instead of radiation oncologists (ROs) might allow for increasing workflow efficiency. This study investigates conformity of adapted target contours provided by dedicated RTTs and ROs. Materials and methods: In a simulated online procedure, 6 RTTs and 6 ROs recontoured targets and organs at risk (OAR) in prostate cancer (n = 2), rectal cancer (n = 2) and lymph node-oligometastases (n = 2) cases. RTTs gained contouring competence beforehand by following a specific in-house training program. For all target contours and the reference delineations volumetric differences were determined and Dice similarity coefficient (DSC), conformity index (CI) and generalized CI were calculated. Delineation time and -confidence were registered for targets and OAR. Impact of contour adaptation on treatment plan quality was investigated. Results: Delineation conformity was generally high with DSC, CI and generalized CI values in the range of 0.81-0.94, 0.87-0.95 and 0.63-0.85 for prostate cancer, rectal cancer and LN-oligometastasis, respectively. Target volumes were comparable for both, RTTs and ROs. Time needed and confidence in contour adaptation was comparable as well. Treatment plans derived with adapted contours did not violate dose volume constrains as used in clinical routine. Conclusion: After tumor site specific training, daily contour adaptations as needed in adaptive online radiotherapy workflows can be accurately performed by RTTs. Conformity of the derived contours is high and comparable to contours as provided by ROs.

20.
Phys Imaging Radiat Oncol ; 24: 43-46, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36148156

RESUMO

Neurovascular bundle (NVB) and internal pudendal artery (IPA) sparing during magnetic resonance-guided radiotherapy (MRgRT) for prostate cancer aims for preservation of erectile function. Our present workflow involves daily online contouring and re-planning on a 1.5 T MR-linac, as alternative to conventional (rigid) translation-only corrections of the prostate. We compared planned dose for the NVB and IPA between strategies. Total planned dose was significantly lower with daily online contouring and re-planning for the NVB, but not for the IPA. For the NVB and IPA, the intrapatient difference between highest and lowest fraction dose was significantly smaller for the contouring and re-planning plans.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...