Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Physiol ; 13: 912049, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35991170

RESUMO

Background: Airway mucus provides important protective functions in health and abnormal viscoelasticity is a hallmark of muco-obstructive lung diseases such as cystic fibrosis (CF). However, previous studies of sputum macrorheology from healthy individuals and patients with CF using different experimental protocols yielded in part discrepant results and data on a systematic assessment across measurement settings and conditions remain limited. Objectives: The aim of this study was to develop an optimized and reliable protocol for standardized macrorheological measurements of airway mucus model systems and native human sputum from healthy individuals and patients with muco-obstructive lung disease. Methods: Oscillatory rheological shear measurements were performed using bovine submaxillary mucin (BSM) at different concentrations (2% and 10% solids) and sputum samples from healthy controls (n = 10) and patients with CF (n = 10). Viscoelastic properties were determined by amplitude and frequency sweeps at 25°C and 37°C with or without solvent trap using a cone-plate geometry. Results: Under saturated atmosphere, we did not observe any temperature-dependent differences in 2% and 10% BSM macrorheology, whereas in the absence of evaporation control 10% BSM demonstrated a significantly higher viscoelasticity at 37°C. Similarly, during the measurements without evaporation control at 37°C we observed a substantial increase in the storage modulus G' and the loss modulus G″ of the highly viscoelastic CF sputum but not in the healthy sputum. Conclusion: Our data show systematically higher viscoelasticity of CF compared to healthy sputum at 25°C and 37°C. For measurements at the higher temperature using a solvent trap to prevent evaporation is essential for macrorheological analysis of mucus model systems and native human sputum. Another interesting finding is that the viscoelastic properties are not much sensitive to the applied experimental deformation and yield robust results despite their delicate consistency. The optimized protocol resulting from this work will facilitate standardized quantitative assessment of abnormalities in viscoelastic properties of airway mucus and response to muco-active therapies in patients with CF and other muco-obstructive lung diseases.

2.
Macromol Rapid Commun ; 42(20): e2100303, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34418212

RESUMO

The mucus layer is a hydrogel network that covers mucosal surfaces of the human body. Mucus has important protective properties that are related to its unique rheological properties, which are based on mucins being the main glycoprotein constituents. Mucin macromolecules entangle with one another and form a physical network that is instrumental for many important defense functions. Mucus derived from various human or animal sources is poorly defined and thus not suitable for many application purposes. Herein, a synthetic route is fabricated to afford a library of compositionally defined mucus-inspired hydrogels (MIHs). MIHs are synthesized by thiol oxidation to render disulfide bonds between the crosslinker ethoxylated trimethylolpropane tri(3-mercaptopropionate) (THIOCURE ETTMP 1300) and the linear precursors, dithiolated linear polyglycerol (LPG(SH)2 ) or polyethylene glycol (PEG(SH)2 ) of different molecular weights. The mixing ratio of linear polymers versus crosslinker and the length of the linear polymer are varied, thus delivering a library of compositionally defined mucin-inspired constructs. Their viscoelastic properties are determined by frequency sweeps at 25 and 37 °C and compared to the corresponding behavior of native human mucus. Here, MIHs composed of a 10:1 ratio of LPG(SH)2 and ETTMP 1300 are proved to be the best comparable to human airway mucus rheology.


Assuntos
Hidrogéis , Muco , Animais , Glicerol , Humanos , Polímeros , Reologia
3.
Colloids Surf B Biointerfaces ; 159: 477-483, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28841497

RESUMO

Osteoarthritis (OA) is a disabling condition especially in the elderly population. The current therapeutic approaches do not halt the OA progression or reverse joint damage. In order to overcome the problem of rapid clearance of hyaluronic acid (HA), a standard viscosupplement for OA, we investigated the rheological properties of a relatively non-degradable dendritic polyglycerol sulfate (dPGS) hydrogel to determine a suitable concentration for intra articular injections that mimics HA in terms of its viscoelastic and mechanical properties. To do so, the concentration range from 3.6 to 4.8wt% of dPGS and, as a reference, blends of commercially available HAs (Ostenil®, GO-ON®, Synocrom® Forte and Synvisc®), were investigated by means of oscillating and flow rheology, thereby yielding storage (G') and loss modulus (G"), as well as yield stress and shear viscosity. In our rheological experiments we observe a pronounced coupling of the molecular weight and the rheological properties for the HAs. Furthermore, we find the dPGS hydrogel to form more compact networks with increasing concentration. From a broader comparison the current findings suggest that an overall polymer concentration of 4.0wt% dPGS has viscoelastic properties that are comparable to hyaluronic acid in the medically relevant frequency range, where for medical application the dPGS hydrogel has the advantage of being much less easily displaced from its injection place than HA.


Assuntos
Hidrogéis/química , Osteoartrite/terapia , Reologia/métodos , Ácido Hialurônico/química , Hidrogéis/uso terapêutico , Resistência ao Cisalhamento , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...