Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Parasite ; 31: 7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38334687

RESUMO

The ISAGA immunocapture test for the detection of anti-Toxoplasma immunoglobulin M is a manual technique known for its excellent sensitivity and specificity. The purpose of this retrospective, multicenter study was to compare the performances and agreement between ISAGA and other IgM detection techniques before cessation of ISAGA production. The analytic performance of the different tests was evaluated using 1,341 serum samples from adults with positive IgM and negative IgG to Toxoplasma gondii, and 1,206 sera from neonates born to mothers with seroconversion. The agreement between the tests was evaluated on 13,506 adult and 5,795 child serum samples. The sensitivity of Toxo-ISAGA IgM® (adults 98.7%, neonates 63.1%) was similar to that of Platelia Toxo IgM® (adults 94.4%, neonates 64.6%), and significantly higher than Liaison Toxo IgM® (adults 90.6%), Architect/Alinity Toxo IgM® (adults 95.7%, neonates 48.6%), and Vidas Toxo IgM® (adults 81.8%, neonates 17.5%). However, the specificities varied between 24.4% (Platelia Toxo IgM®) and 95.2% (Liaison Toxo IgM®) in adults and were >95% for all tests in neonates. An analysis of the kappa coefficients showed better agreement between ISAGA IgM® and the other tests in children (0.75-0.83%) than in adults (0.11-0.53%). We conclude that, in the absence of Toxo-ISAGA IgM®, the association of a very sensitive technique (Platelia Toxo IgM® or Architect/Alinity Toxo IgM®) and a very specific technique (Vidas Toxo IgM® or Liaison Toxo IgM®) is recommended for IgM detection in adult sera. For neonates, Platelia Toxo IgM® appeared to be the best alternative to replace Toxo-ISAGA IgM®.


Title: Performances comparatives des tests ISAGA IgM et ELISA pour le diagnostic des infections maternelles et congénitales à Toxoplasma : quelle technique pourrait remplacer ISAGA IgM ? Abstract: Le test d'immunocapture ISAGA pour la détection des immunoglobulines M anti-Toxoplasma est une technique manuelle connue pour son excellente sensibilité et spécificité. Le but de cette étude rétrospective et multicentrique était de comparer les performances et la concordance entre l'ISAGA et d'autres techniques de détection d'IgM avant l'arrêt de la commercialisation de l'ISAGA. Les performances analytiques des différents tests ont été évaluées à partir de 1 341 échantillons de sérum d'adultes présentant des IgM positives et des IgG négatives à Toxoplasma gondii, et de 1 206 sérums de nouveau-nés nés de mères présentant une séroconversion. La concordance entre les tests a été évaluée sur 13 506 échantillons de sérum d'adultes et 5 795 sérums d'enfants. La sensibilité de Toxo-ISAGA IgM® (adultes 98,7 %, nouveau-nés 63,1 %) était similaire à celle de Platelia Toxo IgM® (adultes 94,4 %, nouveau-nés 64,6 %) et significativement supérieure à celle de Liaison Toxo IgM® (adultes 90,6 %), Architect/Alinity Toxo IgM® (adultes 95,7 %, nouveau-nés 48,6 %) et Vidas Toxo IgM® (adultes 81,8 %, nouveau-nés 17,5 %). Cependant, les spécificités variaient entre 24,4 % (Platelia Toxo IgM®) et 95,2 % (Liaison Toxo IgM®) chez les adultes et étaient >95 % pour tous les tests chez les nouveau-nés. L'analyse des coefficients kappa a montré une meilleure concordance entre ISAGA IgM® et les autres tests chez les enfants (0,75­0,83%) que chez les adultes (0,11­0,53%). Nous concluons qu'en l'absence de Toxo-ISAGA IgM®, l'association d'une technique très sensible (Platelia Toxo IgM® ou Architect/Alinity Toxo IgM®) et d'une technique très spécifique (Vidas Toxo IgM® ou Liaison Toxo IgM®) est recommandée pour la détection des IgM dans les sérums adultes. Pour les nouveau-nés, Platelia Toxo IgM® apparaît comme la meilleure alternative en remplacement de Toxo-ISAGA IgM®.


Assuntos
Toxoplasma , Toxoplasmose Congênita , Toxoplasmose , Criança , Adulto , Feminino , Recém-Nascido , Humanos , Toxoplasmose Congênita/diagnóstico , Toxoplasmose/diagnóstico , Estudos Retrospectivos , Imunoglobulina M , Ensaio de Imunoadsorção Enzimática , Anticorpos Antiprotozoários
2.
J Clin Microbiol ; 61(10): e0035423, 2023 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-37728898

RESUMO

This study aimed to evaluate different serological strategies for the postnatal diagnosis of congenital toxoplasmosis (CT) and establish a biological algorithm for CT diagnosis. The study analyzed serological data of immunoglobulins M, A, and G (IgM, IgA, IgG) performed by immunoenzymatic and compared immunological profile (CIP) assays in 668 newborns with CT diagnosis across four testing periods: P1 (D0- D10), P2 (D11-D35), P3 (D36-D45), and P4 (>D45). Forty-nine percent of the 668 CT cases were diagnosed during P1 and 34%, 4%, and 12% during P2, P3, and P4, respectively. CIP assays detected neosynthetized IgMs/IgGs in 98% of CT cases diagnosed during P1, while IgMs and IgAs were detected in 90% and 57% of CT cases diagnosed during P2 and in 88% and 67% of diagnoses made during P3, respectively. Detection of neosynthesized IgMs/IgGs, IgMs, and IgAs by immunoassay contributed to CT diagnosis in 81%, 77%, and 60% of cases, respectively. In total, 46% of serum samples were positive for all three parameters, 27% for two, and 27% for one of the three. The study recommends using the CIP assay as standard during P1 for CT diagnosis and IgM and IgA immunoassays after P1. A clinical and biological follow-up in a specialized center with a close collaboration between biologists and clinicians is highly recommended to increase the chances of early diagnosis. Overall, this study provides useful information for the development of a biological algorithm for CT diagnosis, which can aid in early detection and appropriate treatment of this disease.


Assuntos
Toxoplasma , Toxoplasmose Congênita , Recém-Nascido , Humanos , Toxoplasmose Congênita/diagnóstico , Estudos Retrospectivos , Anticorpos Antiprotozoários , Imunoglobulina M , Imunoglobulina G , Imunoglobulina A
3.
Parasite ; 30: 19, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37265252

RESUMO

Primary infection during pregnancy by the protozoan Toxoplasma gondii can be worrisome because transmission to the fetus may lead to congenital toxoplasmosis (CT). Neonatal diagnosis is usually performed by serological profile comparison of the mother and newborn. As previously reported in 2012 by C. L'Ollivier et al., three IgM bands at 75, 90 and 100 kDa called the "IgM triplet" has caught our attention and seems to be pathognomonic of CT. This retrospective multicenter study involved nine reference laboratories included in the French National Reference Center for Toxoplasmosis network and concerned determining the specificity and sensitivity of this IgM triplet. On this basis, we were able to propose a new read of the comparison of IgG and IgM immunoblot profiles of mother and infant to increase the sensitivity of this diagnostic marker. The effect of the trimester of pregnancy at the time of infection, but also of maternal treatment with pyrimethamine/sulfadiazine/folinic acid on the presence of this IgM triplet in the infant, could be studied. The presence of the triplet appears pathognomonic for the diagnosis of CT, and it increased the sensitivity of the immunoblot assay from 55.04% to 72.48%. As a result, it would be wise to enhance conventional immunoblot reading by adding the presence of the three IgM bands in the infant pattern for neonatal diagnosis of CT.


Title: La triplette IgM dans le diagnostic néonatal par immunoblot et son utilisation potentielle comme marqueur diagnostique de la toxoplasmose congénitale. Abstract: La primo-infection pendant la grossesse par le protozoaire Toxoplasma gondii peut se révéler préoccupante car la transmission au fœtus peut conduire à une toxoplasmose congénitale (TC). Un diagnostic néonatal est généralement réalisé par comparaison des profils sérologiques de la mère et du nouveau-né. Comme précédemment rapporté en 2012 par C. L'Ollivier et al., l'association de trois bandes d'IgM à 75, 90, et 100 kDa appelée la « triplette IgM ¼ a retenu notre attention et semble être pathognomonique de la TC. Cette étude rétrospective multicentrique impliquant neuf laboratoires de référence inclus dans le réseau du Centre National de Référence pour la Toxoplasmose a permis de déterminer la spécificité et la sensibilité de cette triplette IgM. Ainsi, cela a permis de proposer une nouvelle lecture de la comparaison des profils d'immunoblot IgG et IgM de la mère et du nourrisson pour augmenter la sensibilité de ce marqueur diagnostique. L'effet du trimestre de la grossesse au moment de l'infection mais aussi du traitement maternel par pyriméthamine/sulfadiazine/acide folinique sur la présence de la triplette IgM chez l'enfant a pu être analysé. La présence de cette triplette semble pathognomonique pour le diagnostic de TC et elle permet d'augmenter la sensibilité du test immunoblot de 55,04 % à 72,48 %. Ainsi, il pourrait être judicieux d'améliorer la lecture conventionnelle de l'immunoblot en ajoutant la présence des trois bandes IgM dans le schéma du nourrisson pour le diagnostic néonatal de TC.


Assuntos
Toxoplasma , Toxoplasmose Congênita , Toxoplasmose , Gravidez , Recém-Nascido , Lactente , Feminino , Humanos , Toxoplasmose Congênita/diagnóstico , Anticorpos Antiprotozoários , Immunoblotting , Toxoplasmose/diagnóstico , Imunoglobulina M
4.
Eur J Clin Microbiol Infect Dis ; 42(6): 781-786, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37060382

RESUMO

Toxocariasis is a cosmopolitan helminthiasis linked to contamination with Toxocara cati or Toxocara canis. Only six isolated cases of pleural toxocariasis have been reported in the literature. We describe a case of pleurisy with isolated eosinophilia varying between 600 and 1500/mm3 likely linked o presumptive toxocariasis in a 72-year-old patient. Our patient was admitted to hospital with severe dyspnoea, asthenia and diarrhoea. Imaging studies confirmed right unilateral pleurisy without any parenchymal involvement. Serology of serum and pleural fluid was positive for anti-Toxocara antibodies by ELISA and immunoblotting. Treatment by pleural drainage and anti-parasitic medication with albendazole for 8 days resulted in the resolution of symptoms. A decrease in the levels of polynuclear eosinophils and total IgE confirmed the clinical resolution. The presence of hypereosinophilia in pleural fluid should evoke a diagnosis of pleural toxocariasis. Clinical symptoms and imaging are non-specific, but positive serology for anti-Toxocara antibodies in serum and pleural fluid can confirm the diagnosis.


Assuntos
Eosinofilia , Pleurisia , Toxocaríase , Animais , Humanos , Idoso , Toxocaríase/diagnóstico , Toxocaríase/tratamento farmacológico , Toxocara , Albendazol/uso terapêutico , Ensaio de Imunoadsorção Enzimática , Eosinofilia/diagnóstico , Eosinofilia/tratamento farmacológico , Pleurisia/tratamento farmacológico
5.
Travel Med Infect Dis ; 35: 101509, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31712179

RESUMO

BACKGROUND: Toxoplasmosis is a zoonosis caused by the protozoan Toxoplasma gondii. In immunocompetent patients the infection is usually benign. However, cases of severe and even lethal primo-infections are regularly reported in South America. In contrast, data from tropical Africa are fragmentary. METHODS: Data for French cases of severe toxoplasmosis acquired between 2013 and 2018, in tropical Africa and among immunocompetent patients were collected retrospectively in 2018. RESULTS: Four male patients with a mean age of 34-years were identified. All infections originated in West or Central Africa. The clinical presentations were heterogeneous: two patients had severe disseminated toxoplasmosis, of which one presented with chorioretinitis associated with myositis and the other with febrile pneumopathy; one patient presented with post-infectious acute cerebellar ataxia and the final case had general symptoms and skin manifestations. The diagnosis of acute toxoplasmosis was confirmed by serology in four patients. Molecular diagnosis confirmed T. gondii infection in three patients with Africa 1 as the dominant genotype. The infection was cured with anti-infective treatment in all four patients. Ocular sequelae were reported in the two patients with chorioretinitis. CONCLUSIONS: Imported cases of severe toxoplasmosis in immunocompetent patients are rare in France. However, this aetiology should be evoked rapidly in a patient with a severe infectious syndrome who has recently visited or originated from tropical Africa.


Assuntos
Toxoplasma/isolamento & purificação , Toxoplasmose/complicações , Toxoplasmose/epidemiologia , Adulto , África Subsaariana/epidemiologia , Ataxia Cerebelar/etiologia , Coriorretinite/etiologia , Doenças Transmissíveis Importadas , França/epidemiologia , Humanos , Imunocompetência , Masculino , Miosite/etiologia , Toxoplasma/genética , Toxoplasmose/tratamento farmacológico
6.
Ann Biol Clin (Paris) ; 77(6): 669-680, 2019 12 01.
Artigo em Francês | MEDLINE | ID: mdl-31859644

RESUMO

Although the use of EDTA-containing collection tubes is known to stabilize the complement analytes and to make the results more reliable, no external quality assessment (EQA) scheme based on EDTA plasma samples is available to date in France. Consequently, a number of clinical laboratories currently participate to EQA program on samples whose matrix is different from their routine practice. The aim of this work was to offer a new external quality assessment scheme, as an inter-laboratory exchange (ILE). The ILE samples come from pooled EDTA plasmas of healthy subjects and are diluted to obtain distinct control levels. The protocol has been validated on CH50, C3, C4 and C1-inhibitor measurements, through: (i) a stability study of post-centrifugation storage of EDTA plasma samples at room temperature, 4̊C and -20̊C; (ii) the demonstration of the linearity of the dilution steps; and (iii) a stability study of the diluted samples. Our results demonstrate a four-weeks stability of the ILE samples prepared and stored according to our protocol. Those results are compatible with the ILE implementation constraints, and the program has been implemented in January 2018. The one-year ILE implementation experience is also presented. The newly implemented ILE will be useful for the accreditation of the complement activity of French laboratories using EDTA plasma samples.


Assuntos
Análise Química do Sangue/métodos , Coleta de Amostras Sanguíneas , Proteínas do Sistema Complemento/análise , Ácido Edético/química , Plasma/química , Análise Química do Sangue/normas , Preservação de Sangue/métodos , Preservação de Sangue/normas , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Proteínas do Sistema Complemento/efeitos dos fármacos , Proteínas do Sistema Complemento/metabolismo , Ácido Edético/farmacologia , Excipientes/química , Excipientes/farmacologia , Humanos , Ensaio de Proficiência Laboratorial , Plasma/efeitos dos fármacos , Plasma/metabolismo , Estabilidade Proteica/efeitos dos fármacos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Controle de Qualidade , Fatores de Tempo , Meios de Transporte/normas
7.
Biochem Med (Zagreb) ; 29(3): 030707, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31624460

RESUMO

INTRODUCTION: Reference intervals (RIs) for complement assays in EDTA plasma samples have not previously been published. The objectives of the present study were to validate and/or determine RIs for classical pathway (CP50) activity and C3c, C4 and C1 inhibitor protein (C1INH) assays and to assess the need for age-specific RIs in EDTA plasma. MATERIALS AND METHODS: We retrospectively evaluated a cohort of 387 patients attending our university hospital and known to be free of complement-modifying diseases. The need for age partitioning was assessed and RIs were calculated according to the CLSI protocol. RESULTS: No need for age partitioning was evidenced for CP50 activity, C3c and C4 concentrations and RIs (90% CI) were calculated from the pooled data: 35.4 (33.1-37.2) to 76.3 (73.7-83.6) U/mL for CP50 activity, 0.80 (0.75-0.87) to 1.64 (1.59-1.72) g/L for C3c, and 0.12 (0.10-0.14) to 0.38 (0.36-0.40) g/L for C4. Our results highlight a positive association between age and C1INH concentrations. We derived 3 age partitions (6 months to 30 years, 30-50 and > 50 years) and the related RIs: 0.20 (0.18-0.21) to 0.38 (0.36-0.40) g/L, 0.22 (0.20-0.24) to 0.39 (0.36-0.41) g/L and 0.25 (0.22-0.27) to 0.41 (0.40-0.43) g/L, respectively). CONCLUSIONS: The newly determined RIs for CP50 activity were higher than those provided by the manufacturer for EDTA plasma samples, whereas those for C3c and C4 RIs were similar to the values provided for serum samples. The C1INH concentration and activity were found to be associated with age and age-specific RIs are mandatory for this analyte.


Assuntos
Proteína Inibidora do Complemento C1/metabolismo , Complemento C3c/metabolismo , Complemento C4/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos , Adulto Jovem
8.
Clin Chem Lab Med ; 56(8): 1319-1327, 2018 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-29630506

RESUMO

BACKGROUND: Immunoglobulin G (IgG) and IgG subclass assays are indicated in patients with suspected primary immunodeficiency (PID). Commercially available assays for IgG subclass determination are calibrated against various preparations, and so specific reference values are required for each of them. Using Optilite® reagents from The Binding Site Group Ltd., we sought to determine the pediatric IgG and IgG subclass reference intervals with respect to the ERM-DA470k certified reference material. METHODS: Levels of IgG and IgG subclasses were analyzed in serum samples collected from a large cohort of PID-free children and adolescents. Reference intervals were calculated for previously published age groups (6-12 months, 12-18 months, 18 months-2 years, 2-3 years, 3-4 years, 4-6 years, 6-9 years, 9-12 years and 12-18 years), according to the Clinical and Laboratory Standards Institute's C28-A3c protocol. RESULTS: A total of 456 serum samples were analyzed. The correlation between the total IgG and the sum of the IgG subclasses was good (r2=0.96). No statistically significant gender-specific differences were observed. Our results for the changes over time in IgG and IgG subclass levels are consistent with previous reports. The differences between our lower/upper reference limits and those in the literature are probably due to variations in calibration. CONCLUSIONS: Our present results provide a reliable basis for the diagnosis of PIDs in childhood and for the accreditation of laboratories using Optilite® immunoturbidimetric reagents for IgG subclass measurement. Laboratory scientists and clinicians should be aware of the need for manufacturer-specific IgG subclass reference intervals.


Assuntos
Imunoglobulina G/sangue , Imunoturbidimetria/estatística & dados numéricos , Valores de Referência , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Síndromes de Imunodeficiência/diagnóstico , Imunoturbidimetria/instrumentação , Imunoturbidimetria/métodos , Indicadores e Reagentes , Lactente , Masculino
9.
Am J Trop Med Hyg ; 99(1): 90-93, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29692301

RESUMO

Microsporidia are protists close to the kingdom of fungi that may cause eye infections. Most cases are reported in Asia and affect both immunocompromised and immunocompetent patients. Here, we report a rare case of microsporidial keratoconjunctivitis in an immunocompetent French patient 3 weeks after returning from India. In our patient, Weber trichrome staining of conjunctival scrapings revealed rounded elements approximately 1-3 µm in size. Conventional polymerase chain reaction analysis by ribosomal RNA subunit sequencing showed 100% identity with Vittaforma corneae. Treatment by corneal debridement combined with fluoroquinolone eye drops allowed complete resolution of the lesions. Although rare, ocular microsporidiosis should be investigated in a patient who is native to Asia or has returned from an endemic area and presents with keratoconjunctivitis of undetermined etiology.


Assuntos
Antifúngicos/uso terapêutico , Infecções Oculares Fúngicas/diagnóstico , Fluoroquinolonas/uso terapêutico , Ceratoconjuntivite/diagnóstico , Microsporidiose/diagnóstico , Córnea/efeitos dos fármacos , Córnea/microbiologia , Córnea/patologia , Córnea/cirurgia , Desbridamento/métodos , Infecções Oculares Fúngicas/tratamento farmacológico , Infecções Oculares Fúngicas/microbiologia , Infecções Oculares Fúngicas/cirurgia , França , Humanos , Índia , Ceratoconjuntivite/tratamento farmacológico , Ceratoconjuntivite/microbiologia , Ceratoconjuntivite/cirurgia , Masculino , Microsporidiose/tratamento farmacológico , Microsporidiose/microbiologia , Microsporidiose/cirurgia , Pessoa de Meia-Idade , Viagem , Vittaforma/efeitos dos fármacos , Vittaforma/crescimento & desenvolvimento , Vittaforma/patogenicidade
10.
Travel Med Infect Dis ; 20: 26-30, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29050898

RESUMO

We describe a case of imported cutaneous gnathostomiasis in a Thai patient living in France. Gnathostomiasis is a zoonosis of food origin. The disease is endemic in Southeast Asia and Latin America. However, over the past 30 years, an increasing number of imported cases has been described in Europe and America. The disease is rare in Western Europe and the majority of cases described had a cutaneous clinical presentation. The disease may sometimes be confused with allergy, leading to a delay in diagnosis. Visceral symptoms are rare but may follow severe attacks. A definitive diagnosis can be obtained by the isolation of larvae from skin biopsies, but these are rarely performed. The diagnosis is usually presumptive, based on a combination of anamnestic, clinical, and biological factors. Several courses of the anti-helminths, albendazole or ivermectin, are often necessary. Although rare, the diagnosis should be evoked systematically in a migrant or traveller returning from an endemic area with cutaneous lesions.


Assuntos
Gnathostoma , Gnatostomíase/diagnóstico , Gnatostomíase/tratamento farmacológico , Ivermectina/uso terapêutico , Doença Relacionada a Viagens , Adulto , Animais , Antiparasitários/uso terapêutico , Feminino , Parasitologia de Alimentos , França , Gnatostomíase/epidemiologia , Gnatostomíase/transmissão , Humanos , Pele/parasitologia , Resultado do Tratamento
11.
Front Immunol ; 8: 1862, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29326723

RESUMO

BACKGROUND: An overall response assay [OVA, based on a 23-valent pneumococcal polysaccharide vaccine (PPV23)] is widely used to screen for anti-pneumococcal antibodies. Given the heterogeneity of response from one polysaccharide (PS) to another, a World Health Organization-standardized serotype-specific enzyme-linked immunosorbent assay (SSA) is considered to be the only reliable method for testing anti-PS antibody responses in individuals with suspected primary immunodeficiencies (PIDs). OBJECTIVE: To evaluate the OVA relative to the reference SSA. METHODS: Serum samples of adult patients referred for a suspected PID were collected before and then 4-8 weeks after immunization with PPV23. The anti-pneumococcal response was systematically assessed with an SSA (7-16 serotypes) and interpreted according to the American Academy of Asthma, Allergy and Immunology's current guidelines. We used receiver operating characteristic curves and agreement indices to assess the OVA's diagnostic value in a first cohort. In order to validate these findings, a second (validation) cohort was then prospectively included. RESULTS: Sixty-two adult patients were included, and 42 (67.7%) were defined as poor responders according to the SSA. Only the post-immunization titer in the OVA was able to correctly identify poor responders; a titer below 110 mg/L gave a positive predictive value of 100% [identifying 24 (57.1%) of the 42 poor responders], and similar levels of diagnostic performance were observed in the validation cohort. The pre-vaccination antibody titer, the post/pre-vaccination antibody titer ratio and a post-vaccination titer above 110 mg/L in the OVA were not predictive of the response in the SSA. CONCLUSION: A post-vaccination antibody titer below 110 mg/L in the OVA was constantly associated with a poor PPV23 response using the SSA. In all other cases, SSA is the only reliable method for assessing diagnostic vaccination with PPV23.

12.
Immunol Res ; 64(2): 455-60, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26350265

RESUMO

Autoantibodies are a common feature of rheumatoid arthritis (RA), and their detection is used as a diagnostic tool in medical practice. Rheumatoid factor (RF) and/or anti-citrullinated protein antibodies (ACPA) detection in patients' sera are now included in 2010 ACR/EULAR criteria for RA diagnosis. In this study, we evaluated a new vimentin-derived ACPA ELISA, the anti-cyclic citrullinated peptide high sensitive (CCP hs) test, and we compared its performance with the RF IgM and anti-CCP3 tests on a French multicenter cohort of 84 RA patients, 107 non-RA patients and 100 healthy controls. Sensitivities for RA diagnosis were 71.4, 84.5 and 64.3 % and specificities were 88.4, 86.9 and 87.3 % for CCP hs, CCP3 and RF IgM, respectively. There was a moderate correlation between CCP hs and CCP3 titers (Pearson's r = 0.43; p < 0.0001). These results support the contention that anti-CCP hs antibodies are new reliable ACPA with high specificity for RA.


Assuntos
Artrite Reumatoide/diagnóstico , Artrite Reumatoide/imunologia , Autoanticorpos/imunologia , Peptídeos Cíclicos/imunologia , Adulto , Idoso , Autoanticorpos/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...