Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hum Vaccin Immunother ; 15(3): 717-724, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30462563

RESUMO

Neisseria meningitidis serogroup B (MenB) has caused several recent outbreaks of meningococcal disease on US college campuses. In January 2015, a case of MenB was reported at a university in Oregon, culminating in an outbreak with a total of 7 cases (including 1 fatality) identified over a 5-month period. In response to the outbreak, the university organized a mass immunization campaign with 4 "opt-in" immunization clinics. The preparation, challenges, and resources required for organization and implementation of a mass immunization program in response to an outbreak at a large public university are discussed herein. Based on the logistical challenges as well as resource expenditures associated with planning and executing a mass immunization effort, this experience illustrates that proactive, routine immunization of incoming students is the best strategy for MenB outbreak prevention.


Assuntos
Programas de Imunização , Vacinação em Massa/estatística & dados numéricos , Infecções Meningocócicas/prevenção & controle , Vacinas Meningocócicas/administração & dosagem , Estudantes , Universidades/estatística & dados numéricos , Surtos de Doenças/prevenção & controle , Implementação de Plano de Saúde , Humanos , Vacinação em Massa/legislação & jurisprudência , Infecções Meningocócicas/imunologia , Neisseria meningitidis Sorogrupo B/imunologia , Oregon , Estados Unidos
2.
Phys Ther ; 82(10): 1000-8, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12350214

RESUMO

BACKGROUND AND PURPOSE: Pneumatic compression devices, used as part of the therapeutic strategy for lymphatic drainage, often have cuffs with multiple chambers that are inflated sequentially. The purpose of this study was to investigate (1) the relationship between cuff chamber pressure (P(chamber)) and the pressure on the cuff-skin interface (P(interface)) and (2) the mechanical interaction of cuff chambers and consequences for device control. SUBJECTS AND METHODS: In this study, we used 3 cylindrical (60-, 80-, and 100-mm-diameter) model limbs and 1 ellipsoidal model of the arm to test a commercially available pressure controller using "target pressures," indicated by the controller, of 30, 60, 80, and 100 mm Hg. We studied the time course of P(chamber) and P(interface) during the inflation sequence and the effect of local curvature on P(interface). RESULTS: Our data indicated that, overall, P(interface) is of the same order of magnitude as P(chamber). There was some effect of model diameter and shape, with the smaller curvatures yielding the highest P(interface). Cuff chamber interaction led to P(chamber) and P(interface) values in the most distal (first inflated) chamber that were up to 80% higher than the target pressure. For the 80-mm cylindrical model, for instance, pressure in this chamber reached 54, 98, 121, and 141 mm Hg, respectively, instead of the 30, 60, 80, and 100 mm Hg indicated by the controller. DISCUSSION AND CONCLUSION: The discrepancy between the target pressure, indicated by the controller, and the pressure measured inside the cuff chambers undermines the therapeutic control and efficacy of the pneumatic compression devices. Because the measured pressures were far beyond the pressure level indicated by the controller, it is recommended that pneumatic compression devices be used at much lower target pressures (<30 mm Hg) than those applied in clinical practice.


Assuntos
Braço , Determinação da Pressão Arterial/métodos , Linfedema/terapia , Torniquetes , Análise de Variância , Determinação da Pressão Arterial/normas , Neoplasias da Mama/radioterapia , Constrição , Desenho de Equipamento , Feminino , Humanos , Linfedema/etiologia , Pressão , Reprodutibilidade dos Testes , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...