Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
J Prosthodont ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594924

RESUMO

PURPOSE: Bioceramic coatings have been shown to promote bone repair, which aids in the early integration of implants. This study aimed to evaluate the influence of air abrasion with a bioceramic abrasive on the surface characteristics of different implant materials and surfaces. The dissolution of the applied treatment from the surfaces over 3 weeks was also assessed. MATERIALS AND METHODS: Discs of three alloys used for dental implants were studied and compared: two types of commercially pure titanium (CpTi)/ (CpTi SLActive) and titanium-zirconia (TiZr). The tested surfaces were: CpTi control (CpC), sandblasted (SB), sandblasted and acid-etched (SBE), and CpTi SLActive®, (TiZr) Roxolid®. Three discs from each group underwent air abrasion with apatite bioceramic powders, 95% hydroxyapatite (HA)/5% calcium oxide (CaO), and 90% hydroxyapatite (HA)/10% calcium oxide (CaO). The treated discs were surface characterized by optical profilometry to obtain surface roughness, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) to compare element weight percentages of titanium, calcium, and phosphate. Dissolution was assessed using inductively coupled plasma optic emission spectrometry (ICP-OES). RESULTS: Bioceramic powders were deposited on all tested surfaces leading to changes in surface characteristics. The only statistically significant differences between the material groups for surface roughness were found with 95% HA/5% CaO powder in the Sp and Rp parameters (p = 0.03 and 0.04, respectively). There were no significant differences in the Ca and P wt% between all groups and powders 95% HA/5% CaO and 90% HA/10% CaO (p = 0.14, 0.18, and p = 0.15, 0.12, respectively). A non-uniform dispersion of the treatment on the surface layer was visible on all treated surfaces. The bioceramic powder continued to dissolute from the tested surfaces for 3 weeks. CONCLUSION: Bioceramic abrasion modifies implant surface characteristics, although the change in surface characteristics resulting from such treatment was not influenced by the implant material or surface treatment. Air abrasion with hydroxyapatite and calcium oxide bioceramics leaves powder deposits on the treated implant surfaces that could potentially influence the healing of implants affected by peri-implantitis.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38536725

RESUMO

INTRODUCTION: This study aims to investigate the effect of different particle sizes and pressures on the shear bond strength (SBS) and the roughness (Ra) of polyetheretherketone. MATERIALS AND METHODS: A total of 117 polyetheretherketone specimens were fabricated and divided into a control (CN: no air-particle abrasion) and eight pre-treatment groups (air-abraded with 50- or 110-µm Al2O3 particles at 1(A), 1.5(B), 2(C), and 2.5(D) bar). The adhesive, Visio.link was used. Thermal aging was performed. Surface properties, SBS and failure mode were assessed. Data was analyzed by linear regression, Pearson correlation and Dunnett's T3 test for pairwise comparisons (p⟨0.05). RESULTS: The highest and lowest Ra were found in the 110D and CN groups respectively, and the highest SBS results were obtained from the 50B group. Pressure and particle size showed significant difference on the investigated properties (p⟨0.001). Only adhesive failure was observed in the CN, and resin cohesive failure was observed in addition to adhesive failure in the overall study groups. CONCLUSION: The air-borne particle abrasion procedures and the adhesive material combination are critical to the strength of the polyetheretherketone bond. The combination of visio.link with the pre-treatment option of 50-µm Al2O3 particles applied at 1.5-bar pressure delivered the most favorable results.

3.
J Biomed Phys Eng ; 14(1): 99-110, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38357598

RESUMO

The selection of abrasive material and parameters of the Air-Abrasion device for a particular application is a crucial detail. However, there are no standard recommendations or manuals for choosing these details; the operator must depend on his experience and knowledge of the procedure to select the best possible material and set of parameters. This short review attempts to identify some of the effects that the selection of material and parameters could have on the performance of the Air-Abrasion procedure for a particular application. The material and parameter data are collected from various studies and categorized according to the most popular materials in use right now. These studies are then analyzed to arrive at some inferences on the performance of Air-Abrasion materials and parameters. This review arrives at a few conclusions on the effectiveness of a material and parameter set, and that there is potential for developments in the area of standardizing parameter selection; also, there is scope for further studies on Bio-Active Glass as an alternative to the materials currently used in Air-Abrasion.

4.
J Oral Sci ; 66(1): 42-49, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38233153

RESUMO

PURPOSE: To compare the shear-bond-strength (SBS) of a highly-filled-flowable composite (HFFC) and a paste-type composite for indirect composite repair and to evaluate the effect of different surface treatments (ST), concerning the composite repair protocol. METHODS: Eighty-four 5 × 5 × 2 mm cylindrical specimens were prepared using Gradia Plus and SR Nexco indirect composite materials. The samples were thermocycled 5,000 times. According to the ST, the samples were divided into three groups (control, bur, and air-abrasion). After ST, the sample subgroups were divided into two sub-groups according to the repair material: paste-type composite and HFFC (n = 7). Another 5,000 cycles of aging were performed. SBS values were measured with a universal testing machine (Shimadzu, Japan). Shapiro-Wilk, 3-way ANOVA, and Tukey HSD test were used to evaluate data (P < 0.05). RESULTS: ST was considered significant for SBS (P < 0.001). The mean values were (13.9 ± 5.7), (17.0 ± 6.4), (20.4 ± 4.9) MPa for the control, bur and phosphoric acid, and air-abrasion groups, respectively. The surface treatment and repair material interaction was considered significant for SBS (P = 0.044). The highest mean bond strength (24.5 ± 4.5 MPa) was observed for the interaction of SR Nexco, air-abrasion ST, and HFFC repair. CONCLUSION: Repairing with HFFC following air abrasion might enhance the SBS for indirect composite restorations.


Assuntos
Abrasão Dental por Ar , Colagem Dentária , Abrasão Dental por Ar/métodos , Colagem Dentária/métodos , Propriedades de Superfície , Resinas Compostas , Japão , Teste de Materiais , Resistência ao Cisalhamento
5.
J Prosthodont Res ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38296526

RESUMO

PURPOSE: To evaluate the effect of chemical, mechanical, and combination surface treatments on the shear bond strength (SBS) of autopolymerizing repair resins to conventional heat-cured, computer aided design (CAD)-computer aided manufacturing (CAM) milled, and three-dimensionally (3D) printed denture base materials. METHODS: Specimens were fabricated and divided according to the surface treatment as follows: no surface treatment (control group), monomer treatment (monomer group), resin remover treatment (resin remover group), roughening with 180 FEPA grit abrasive paper followed by monomer treatment (180-grit plus monomer group), and air particle abrasion (air abrasion group). Autopolymerizing resin cylinders were attached before accelerated aging of the specimens in water at 100 °C for 16 h. The SBS was tested using a universal testing machine. Surface roughness was evaluated using a 3D optical profilometer. Scanning electron microscopy (SEM) and stereomicroscopy were used for surface analysis. Data was collected and analyzed using analysis of variance (ANOVA) and Kruskall-Wallis tests (α = 0.05). RESULTS: The denture base material and surface treatment significantly affected the SBS. The milled Temp Basic Tissue demonstrated the highest SBS values across all surface treatments, whereas the two 3D-printed denture base materials exhibited the lowest SBS values. CONCLUSIONS: The bond strength of CAD-CAM-milled denture base resins to autopolymerizing repair resins is comparable to that of heat-cured resins. Surface roughening using air particle abrasion or 180-grit carbide paper can enhance the bond strength of the autopolymerizing repair resin to 3D-printed denture base materials.

6.
J Esthet Restor Dent ; 36(4): 620-631, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37950565

RESUMO

OBJECTIVE: Obtaining strong resin bonds to computer-aided design and computer-aided manufacturing (CAD-CAM) resin-based composites with dispersed fillers (CCRBCs) poses a challenge. Therefore, this study aimed to assess the effect of three universal adhesives and a two-component silane coupling agent on the shear bond strength to three (CCRBCs). MATERIALS AND METHODS: Eight hundred and sixty-four specimens of Brilliant Crios, Lava Ultimate, and Tetric CAD were polished or grit blasted, bonded with Adhese Universal DC, One Coat 7 Universal (OC7), and Scotchbond Universal Plus Adhesive (SBU) with or without a silane primer. Shear bond strength was measured after 24 h and 10,000 thermocycles. Linear regressions were performed (α = 0.05). RESULTS: After thermocycling, bond strengths were similar for the universal adhesives on polished Brilliant Crios and Lava Ultimate (p ≥ 0.408). Grit blasted Tetric CAD showed no significant differences (p ≥ 0.096). The silane primer had minimal impact on grit blasted Tetric CAD (p ≥ 0.384). The silane primer increased the bond strength of OC7 to Brilliant Crios (p = 0.001) but decreased the adhesion of SBU to Brilliant Crios and Lava Ultimate (p ≤ 0.018). CONCLUSIONS: Bond strength of universal adhesives varied with CCRBC type. The two-component silane coupling agent showed mixed effects on adhesive performance. CLINICAL SIGNIFICANCE: Selecting universal adhesives from the same CCRBC product line does not always guarantee superior bond strength. The efficacy of silane coupling agents differs based on the bonding substrate.


Assuntos
Colagem Dentária , Silanos , Silanos/química , Cimentos Dentários , Propriedades de Superfície , Materiais Dentários , Cimentos de Resina/química , Desenho Assistido por Computador , Teste de Materiais
7.
J Esthet Restor Dent ; 36(5): 746-760, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38130045

RESUMO

OBJECTIVE: This scoping review aims to assess the influence of air abrasion with aluminum oxide and bioactive glass on dentin bond strength. MATERIALS AND METHODS: An electronic search was conducted in three databases (PubMed, Cochrane Library, and Embase), on March 3rd, 2023, with previously identified MeSH Terms. A total of 1023 records were screened. Exclusion criteria include primary teeth, air abrasion of a substrate other than sound dentin, use of particles apart from aluminum oxide or bioactive glass, and studies in which bond strength was not assessed. RESULTS: Out of the 1023 records, title and abstract screening resulted in the exclusion of 895 and 67 studies, respectively, while full-text analysis excluded another 25 articles. In addition, 5 records were not included, as full texts could not be obtained after requesting the authors. Two cross-references were added. Thus, 33 studies were included in this review. It is important to emphasize the absence of standardization of air abrasion parameters. According to 63.6% of the studies, air abrasion does not influence dentin bond strength. Moreover, 30.3% suggest improving bonding performance, and 6.1% advocate a decrease. CONCLUSIONS: Air abrasion with aluminum oxide does not enhance or impair dentin bond strength. The available data on bioactive glass are limited, which hinders conclusive insights. CLINICAL SIGNIFICANCE: Dentin air abrasion is a widely applied technique nowadays, with numerous clinical applications. Despite the widespread adoption of this procedure, its potential impact on bonding performance requires a thorough analysis of the existing literature.


Assuntos
Resinas Compostas , Colagem Dentária , Resinas Compostas/química , Colagem Dentária/métodos , Abrasão Dental por Ar/métodos , Teste de Materiais , Propriedades de Superfície , Óxido de Alumínio/química , Dentina , Cimentos de Resina/química
8.
Brain Neurorehabil ; 16(3): e22, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38047095

RESUMO

Cerebral air embolism (CAE) occurs in various clinical situations such as surgery, angiography, and hemodialysis; most are iatrogenic. Here we report the case of a 57-year-old man who developed CAE immediately after air-powder abrasive treatment, which is commonly used in dentistry. The patient underwent air-powder abrasive treatment for peri-implantitis, and immediately after the treatment, cardiac arrest occurred and cardio- pulmonary resuscitation was performed. After resuscitation, brain computed tomography performed in the emergency room showed scattered dark density presumed to be air. The day after admission, the patient showed right hemiplegia and a multifocal cerebral infarction was observed on brain magnetic resonance imaging. Therefore, CAE was strongly suspected. After hyperbaric oxygen treatment (HBOT), which started 4 days after the incident, the patient regained consciousness and showed improvement in cognitive impairment, and only grade 4 muscle weakness was observed in the right lower extremity on the manual muscle test. This case highlights the importance of considering CAE as a possible cause of neurological symptoms occurring during clinical procedures involving air, and adds to the accumulation of evidence of therapeutic effects of delayed HBOT.

9.
Cureus ; 15(11): e48883, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38024043

RESUMO

The aim of the study was to evaluate the effect of airborne particle abrasion (using different sizes of alumina particles) on the shear bond strength (SBS) between cast and milled titanium metal frameworks and auto-polymerizing acrylic repair resin. Forty flat cylindrical titanium disks were divided into two main divisions: cast and milled titanium. The two divisions were further subdivided into four groups based on metal surface treatment. Three particle sizes of aluminum oxide air abrasive powders (50µm, 110µm, and 250µm) were used for metal surface treatment by airborne particle abrasion. One group was the control group with no surface treatment. Auto-polymerizing acrylic repair resin was applied to all titanium disks. The specimens were subjected to SBS testing using a universal testing machine (Instron Corporation, Norwood, Massachusetts, United States). Surface evaluation was performed using a scanning electron microscope. One-way ANOVA was used for statistical analysis. The results showed a significant increase in SBS after airborne particle abrasion of both milled and cast titanium groups (p<0.001). The SBS was directly proportional to the size of the aluminum oxide particles. The milled titanium group showed higher SBS values than the cast group when the surface was not treated with alumina particles (p < 0.001) and when the surface was treated with the smaller particle sizes of 50 µm, whereas the cast group demonstrated higher SBS values than the milled group (p < 0.01) when the particle size was increased to 110 µm and 250 µm. It could be concluded that SBS between titanium metal frameworks and auto-polymerizing repair acrylic resin was directly related to the size of the alumina airborne particle abrasives. The fabrication method of the titanium framework also influenced the SBS as the untreated milled frameworks demonstrated favorable SBS values compared to the untreated cast frameworks.

10.
Clin Oral Investig ; 27(12): 7833-7840, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37989965

RESUMO

OBJECTIVES: To assess the effect of glass-ceramic coated zirconia versus alumina air-abraded zirconia on the shear bond strength (SBS) of resin cement and investigate the residual stresses present on both mechanically pre-treated surfaces. MATERIALS AND METHODS: A total of 180 zirconia disks, with diameters of 10 mm and 5 mm, were divided into two groups: DCMhotbond glass-ceramic coated, followed by hydrofluoric acid etching (DCM), and alumina air-abraded (AB). All mechanically pre-treated disks were conditioned with G-Multi Primer and bonded using G-Cem Linkforce Cement. Ninety specimens were immersed in distilled water for 24 h and subsequently allocated into three groups based on aging conditions (n = 15/subgroups): immediate testing, 5000 thermal cycles, and 10,000 thermal cycles. Then, the shear bond strength was assessed, and the obtained data were subjected to analysis using a two-way ANOVA, followed by a one-way ANOVA and Tukey's HSD post hoc test (α = 0.05). The residual stresses present on both mechanically pre-treated surfaces were examined using X-ray diffraction analysis. RESULTS: The mean SBS values of the DCM and AB groups showed no significant difference under each aging condition. The SBS of DCM groups was not affected by thermal cycles, whereas the SBS of AB groups exhibited a significant decrease following thermal cycles. Glass-ceramic coated surfaces exhibited higher compressive stresses than alumina air-abrasion. CONCLUSIONS: The DCMhotbond glass-ceramic coated zirconia showed comparable bond strength to the alumina air-abrasion technique. CLINICAL RELEVANCE: The DCMhotbond glass-ceramic coating technique is a promising alternative for zirconia surface pre-treatment. However, further investigations are needed before suggesting its clinical use.


Assuntos
Colagem Dentária , Óxido de Alumínio/química , Propriedades de Superfície , Cerâmica/química , Cimentos de Resina/química , Zircônio/química , Resistência ao Cisalhamento , Teste de Materiais , Análise do Estresse Dentário
11.
J Mech Behav Biomed Mater ; 148: 106167, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37837875

RESUMO

This study aimed to assess the effect of low-temperature degradation (LTD) and surface treatment on the flexural strength of additive-manufactured (AM) zirconia by comparison to subtractive-manufactured (SM) zirconia. Disc-shaped zirconia specimens were fabricated using AM and SM technology, and each group was assigned to 3 subgroups according to the type of surface treatment: control, sandblasting (SB), and 9% hydrofluoric acid etching (HF). The groups were then further divided into 2 subgroups: unaged and aged. Biaxial flexural strength, crystal phase, surface topography, and surface roughness were measured to evaluate the mechanical properties. Statistical analyses were performed with 3-way ANOVA, followed by the comparison of means with Bonferroni post hoc analyses. The means and standard deviations of the biaxial flexural strength and Weibull parameters were calculated with descriptive statistics. All SM groups showed significantly greater flexural strength than the AM groups (p < .05), and LTD did not affect flexural strength except for the SMHF group (p < .05). After LTD, monoclinic phases (m-phase) were found in all groups, and SEM images showed grain pullout due to zirconia volume expansion in both control groups. Sandblasting significantly affected flexural strength (p < .05), whereas the HF group did not affect flexural strength except in the SMHF group after LTD (p < .05). No significant difference was observed in the surface roughness of AM compared to SM groups conditioned with the same surface treatment regardless of LTD. AM zirconia has comparable mechanical properties to SM zirconia, regardless of low-temperature degradation and surface treatment, which indicates the potential of the AM technique for clinical applications.


Assuntos
Resistência à Flexão , Zircônio , Teste de Materiais , Temperatura , Propriedades de Superfície , Zircônio/química , Cerâmica , Ítrio/química , Materiais Dentários
12.
Materials (Basel) ; 16(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37763518

RESUMO

This study aimed to evaluate the effects of surface treatments and resin cement on the adhesion of ceramic and ceramic-like materials to titanium. A total of 40 specimens (5 mm diameter) of each material (lithium disilicate glass ceramic (LDGC-IPS e.maxCAD), lithium silicate glass ceramic (LSGC-VITA Suprinity) and a polymer-infiltrated ceramic network (PICN-Vita Enamic)) were fabricated using CAD/CAM technologies. In total, 120 titanium (Ti) specimens were divided into 12 groups, and half of the titanium specimens were tribochemically coated using CoJet. The titanium and all-ceramic specimens were cemented using either Self-curing adhesive cement (SCAC-Panavia 21) or a Self-curing luting composite (SCLC-Multilink Hybrid Abutment). After 5000 cycles of thermal aging, the shear bond strength (SBS) test was conducted using a universal testing machine. The failure modes of the specimens were analyzed using stereomicroscopy, and additionally, the representative specimens were observed using Scanning Electron Microscopy. ANOVA was used for the statistical analysis (p < 0.05). The post-hoc Duncan test was used to determine significant differences between the groups. The mean SBS values (mean ± STD) ranged from 15 ± 2 MPa to 29 ± 6 MPa. Significantly higher SBS values were acquired when the titanium surface was tribochemically coated (p < 0.05). The SCLC showed higher SBS values compared to the SCAC. While the LDGC showed the highest SBS values, the PICN presented the lowest. The tribochemical coating on the cementation surfaces of the titanium increased the SBS values. The specimens cemented with the SCLC showed higher SBS values than those with the SCAC. Additionally, the SCLC cement revealed a more significant increase in SBS values when used with the LDGC. The material used for restoration has a high impact on SBS than those of the cement and surface conditioning.

13.
J Mech Behav Biomed Mater ; 146: 106101, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37659166

RESUMO

The aim of the present study was to evaluate the impact of two Er,Cr:YSGG laser surface treatments on the repair bond strength of a dental CAD/CAM resin composite (Brilliant Crios) after artificial aging. Twenty-four resin-based CAD/CAM blocks were cut and 48 rectangular slabs (3 x 12 x 14 mm) were prepared. Preliminary SEM observations indicated the most favorable laser settings regarding surface modification of the tested restorative material. The CAD/CAM specimens were then divided into 4 groups (n=12) based on their surface pretreatment: no treatment, air abraded with 50-µm Al2O3 particles, and laser irradiated with two different protocols using Er,Cr:YSGG laser with average power 3.5 and 4.5 W, pulse repetition rate 35 and 50 Hz, and pulse energy 100 and 90 mJ, respectively. After surface treatments each group followed a bonding protocol with silane and a flowable resin composite was used to prepare 48 microrods. Half of the microrods of each group were subjected on shear bond strength (SBS) test (chisel-shaped blade, load cell of 500 N, crosshead speed of 1 mm/min) after 24 h, while the other half underwent artificial aging (15,000 cycles, 5-55 °C) and then SBS test. The debonded specimens were examined under an optical microscope to determine the failure mode. All specimens were also evaluated using SEM to assess the surface topography after the treatments. The results showed that SBS significantly decreased after thermocycling in all the experimental groups (p<0.05). Control group presented much lower SBS values than the other groups after both 24 h and thermocycling (p<0.05). The highest values of SBS exhibited air-abrasion group (p<0.05), followed by the two laser groups, which did not differ to each other (p>0.05). The results of the current study indicated that Er,Cr:YSGG laser irradiation can be an alternative treatment for repairing the tested resin-based CAD/CAM restorative material.


Assuntos
Lasers de Estado Sólido , Desenho Assistido por Computador , Microscopia , Resistência ao Cisalhamento
14.
Dent Res J (Isfahan) ; 20: 46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37304424

RESUMO

Background: The goal of this study is to determine the effect of different sandblasting particles and dental adhesive systems on the repair strength of dimethacrylate-based composite resins. Materials and Methods: In this in-vitro study, 96 specimens of X-trafil composite blocks were prepared and divided into eight groups (n = 12). Four groups were sandblasted with Aluminum Oxide (AL) and four other groups with Bio-Active Glass particles (BAG). A two-component silane was applied on the surface of all the samples after phosphoric acid etching and rinsing. Two groups of the sandblasted specimens were treated with Clearfil SE Bond (CSB) and the other two groups were treated with Single Bond Universal (SBU) and new composite was bonded to the prepared surfaces. Half of the specimens in each group were thermocycled. Shear force was applied to the bonded composite using a universal testing machine with a crosshead speed of 0.5 mm/min and mean shear bond strength (MSBS) was calculated (MPa). The data was analyzed using Kruskal-Wallis and Man-Whitney U-tests with the significance level of 0.05. Results: Significant differences were observed between different groups (P < 0.001). The highest and the lowest MSBS of the thermocycled samples were reported 18.88 MPa with application of AL and SBU and 11.46 MPa with the application of AL and CSB, respectively. No significant difference was observed with application of BAG particles after thermocycling. Conclusion: Effect of AL on repair shear bond strength of composite resins is affected by bonding type. Bonding type did not affect repair shear bond strength of BAG. Thermocycling reduced bond strength in all groups.

15.
Dent Res J (Isfahan) ; 20: 25, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36960018

RESUMO

Background: During the orthodontic bonding process, the need for repositioning or rebonding of orthodontic brackets on the enamel surface occurs frequently. The aim of this study is to compare the shear bond strength (SBS) in rebonding orthodontic stainless steel brackets with three different methods of enamel surface conditioning methods. Materials and Methods: In this in vitro study, 80 human premolars that were extracted for orthodontic purposes were randomly divided into four groups and underwent orthodontic bonding procedure (N = 20). Except for the control group, three other groups underwent debonding and rebonding process in which after removing the remaining adhesive with tungsten-carbide bur, enamel surface conditioned by three different methods including re-etching with phosphoric acid, sandblasting + acid etching, and Erbium-doped Yttrium-Aluminum-Garnet laser. Then, the SBS of the bracket to the enamel surface was compared between different groups. Scanning Electron microscopy images were also obtained from a number of samples. Statistical analysis was performed by Kruskal-Wallis and Mann-Whitney tests. Results: The highest SBS was observed in the primary bond (control group) with an average of 29,440 MPa. There was a significant difference between the studied groups (P < 0.001) and only the group that was re-etched with phosphoric acid had no significant difference with the control group (P = 0.708) ∝ =0.05. Conclusion: Rebonding of brackets using phosphoric acid for reconditioning of the enamel surface creates bond strength comparable to the primary bond. Other groups had significantly lower SBS than the control group.

16.
Clin Implant Dent Relat Res ; 25(3): 549-563, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36918345

RESUMO

OBJECTIVES: Analysis of the in vitro efficacy of non-surgical and surgical dental implant surface decontamination with or without suprastructure. MATERIALS AND METHODS: Three hundred and sixty implants were dipped in indelible red and distributed to 30°, 60°, or 90° angulated bone defect models. One hundred and twenty implants were used for each bone defect, 40 of which were assigned to a decontamination method (CUR: curette; SOSC: soundscaler; APA: air powder abrasion). Of these, 20 were subjected to a simulated non-surgical (NST) or surgical treatment (ST), with/without mucosa mask, of which 10 were carried out with (S+) or without (S-) suprastructure. Uncleaned implant surface was assessed by both-sided implant surface photography. Surface morphology changes were analyzed using scanning electron microscopy (SEM). RESULTS: Cleaning efficacy was significantly better within NST if the suprastructure was removed (p < 0.001). No significant difference was found within ST (p = 0.304). Overall, cleaning efficacy in the order APA > SOSC>CUR decreased significantly (p < 0.0001) for both S+ and S- in NST as well as ST. Separated by NST/ST, S+/S-, defect angulation and decontamination method, only isolated significant differences in cleaning efficacy were present. Linear regression analysis revealed significant associations of remnants with the treatment approach, decontamination method, and defect angle (p < 0.0001). SEM micrographs showed serious surface damage after use of CUR and SOSC. CONCLUSIONS: Suprastructure removal is an additional option to improve cleaning efficacy of non-surgical implant surface decontamination in this in vitro model.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Descontaminação/métodos , Propriedades de Superfície , Microscopia Eletrônica de Varredura , Pós , Peri-Implantite/terapia
17.
Braz. dent. j ; 34(1): 71-79, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420573

RESUMO

Abstract This study aimed to investigate the failure behavior of 3 mol.% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) prosthetic crowns air-abraded with aluminum oxide (AO) particles of different sizes. Ninety ceramic premolar crowns were produced with 3Y-TZP frameworks veneered with porcelain. Crowns were randomly divided into three groups, according to the size of the air abrasion AO particles (n = 30): (GC) untreated (control); (G53) 53 µm; (G125) 125 µm. Air abrasion was performed with 0.25 mpa pressure, 10-mm distance, for 10 s. Crowns were adhesively cemented to dentin analog abutments. Specimens were loaded in compression to failure, in 37oC distilled water, using a universal testing machine (n = 30). Fractographic analysis was performed using a stereomicroscope and SEM. The roughness of the crown's inner surface was evaluated using an optical profilometer (n = 10). Fracture load data were statistically analyzed with Weibull analysis and roughness data with Kruskal-Wallis (α = 0.05). GC had the lowest characteristic fracture load (L0), while G53 and G125 had higher and statistically similar L0 values. The Weibull modulus (m) was similar among groups. The failure modes observed were catastrophic failure and porcelain chipping. There were no differences between the roughness parameters for the experimental groups (p > 0.05). The size of the AO particles did not affect the fracture load and failure mode of 3Y-TZP crowns. Air abrasion with 53 µm and 125 µm particles resulted in a higher fracture load of ceramic crowns than the untreated group while maintaining their reliability and surface characteristics.


Resumo O objetivo deste estudo foi investigar o efeito do jateamento com óxido de alumínio (AO) com diferentes tamanhos de partículas no comportamento de fratura de coroas protéticas de zircônia tetragonal estabilizada com 3 mol% de ítria (3Y-TZP). Noventa coroas cerâmicas de pré-molares foram produzidas com infraestruturas de 3Y-TZP recobertas com porcelana. As coroas foram divididas aleatoriamente em três grupos, de acordo com o tamanho das partículas de AO do jateamento (n = 30): (GC) não tratada (controle); (G53) 53 µm; (G125) 125 µm. O jateamento foi realizado com pressão de 0,25 MPa, distância de 10 mm, por 10 s. As coroas foram cimentadas adesivamente em pilares análogos à dentina. As coroas foram testadas em compressão até a falha, em água destilada a 37ºC, usando uma máquina universal de ensaios (n = 30). A análise fractográfica foi realizada usando estereomicroscópio e MEV. A rugosidade da superfície interna das coroas foi avaliada usando um perfilômetro óptico (n = 10). Os dados de carga de fratura foram analisados ​​estatisticamente com análise de Weibull e os dados de rugosidade com Kruskal-Wallis (( = 0,05). GC apresentou a menor carga característica de fratura (L0), enquanto G53 e G125 apresentaram valores de L0 maiores e estatisticamente semelhantes. O módulo de Weibull (m) foi semelhante entre os grupos. Os modos de falha observados foram falha catastrófica e lascamento da porcelana. Não houve diferenças entre os parâmetros de rugosidade para os grupos experimentais (p > 0,05). O tamanho das partículas de AO não afetou a carga de fratura e o modo de falha das coroas 3Y-TZP. O jateamento com partículas de 53 µm e 125 µm resultou em maior carga de fratura das coroas cerâmicas do que o grupo não tratado, mantendo sua confiabilidade e características de superfície.

18.
Polymers (Basel) ; 15(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36679326

RESUMO

This study compared the shear bond strength (SBS) and micromorphology of composite resin to human dentin after pre-treatment with silica-modified aluminum oxide air abrasion. Forty-six molar teeth were treated with either Scotchbond Multi-Purpose (SCMP) or Clearfil SE Bond (CLSE) adhesive. Buccal surfaces were pre-treated with the CoJet air abrasion system (SB), and lingual surfaces were controls. The adhesion of light-cured resin composite to the treated dentin surface was evaluated with SBS. After debonding, substrate surfaces were examined with an optical microscope for failure analysis. In addition, 15 molar teeth were sectioned and randomly assigned to one of five groups, according to the dentin surface pre-treatment and adhesive type, and examined with high-vacuum scanning electron microscopy/energy dispersive X-rays (SEM/EDS). The type of adhesive had a significant effect on SBS (p = 0.000); CLSE had the highest values. SB did not affect SBS (p = 0.090). SEM/EDS revealed residual aluminum and/or silicon on all dentin surfaces after SB, except for the control. Treatment with 32% phosphoric acid in the SCMP adhesive decreased the amounts of aluminum and silicon compared to SB dentin only, whereas CLSE resulted in similar quantities of aluminum and silicon as air-abraded dentin. The results of this study indicate that CLSE might have a higher bond strength to dentin than SCMP. Pre-treatment with SB does not appear to affect bonding strength.

19.
J Microsc ; 289(3): 180-186, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36510481

RESUMO

The aim of this study was to compare two different imaging methods by assessing changes caused by sodium bicarbonate and glycine air polishing on the tooth surfaces. Fourteen single root teeth with exposed root surfaces were included into the study. The teeth were randomly divided into two groups: sodium bicarbonate and glycine group. Samples were scanned in a micro-computed tomography (micro-CT) and CAD/CAM (computer-aided design/computer-aided manufacturing) at baseline and then after air-polishing powder applications, the defect volume values were evaluated. There was a statistically significant difference between mean defect volume values that occurred after glycine and sodium bicarbonate air polishing evaluated with micro-CT and CAD/CAM (p < 0.05). After sodium bicarbonate air polishing, defect volume on enamel surface at maximum power and defect volume on the exposed root surface at medium power values calculated with CAD/CAM were higher. After glycine air polishing, defect volume values on both surfaces at medium power setting calculated with CAD/CAM were lower. Defect volume values on enamel surface at maximum power setting calculated with CAD/CAM were higher than calculated with micro-CT. We concluded that CAD/CAM cannot provide as accurate results as micro-CT. Glycine-based powder is less abrasive than sodium bicarbonate, especially on enamel surface. Lay Description: Micro-CT is a non-destructive imaging method with high resolution and allows to examine all tooth structures individually. CAD/CAM are systems that are widely used in dentistry today. Access to the device is easier than micro-CT. Intraoral scanners in CAD/CAM systems also provide non-destructive image scanning. The aim of this study was to compare two different imaging methods by assessing changes caused by sodium bicarbonate and glycine air polishing on the tooth surfaces. The results showed that because of the analyses made with CAD/CAM, similar results could not be obtained with micro-CT and cannot be used to evaluate the changes that occur after air polishing.


Assuntos
Polimento Dentário , Glicina , Bicarbonato de Sódio , Glicina/química , Pós , Bicarbonato de Sódio/química , Propriedades de Superfície , Microtomografia por Raio-X , Polimento Dentário/métodos , Dente , Humanos
20.
Clin Oral Investig ; 27(1): 31-43, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36441267

RESUMO

OBJECTIVES: The influence of different cleaning methods, air-abrasion parameters, and aging on shear bond strength (SBS) and tensile bond strength (TBS) of 3D resin luted to composite resin. MATERIALS AND METHODS: Nine hundred resin substrates were 3D printed (D20II, Rapid Shape) and cleaned with either isopropanol (ISO), butyldiglycol-based solution (BUT), or centrifugation (CEN). After 24-h storage in 37 °C water, specimens were air-abraded (mean particle size 50 µm; n = 60) with either alumina at 0.1 MPa (AL0.1) or 0.4 MPa (AL0.4) and glass pearls at 0.1 MPa (GP0.1) and 0.4 MPa (GP0.4) or conditioned with visio.link (control) and luted with PanaviaV5. Initially (24 h, 37 °C water storage) or after aging (10,000 thermal cycles), SBS and TBS were measured, and fracture types were examined. Surface free energy (SFE) and roughness (Ra) were determined after air-abrasion. Kolmogorov-Smirnov, Kruskal-Wallis H, Mann-Whitney U, chi-square, and partial eta-squared were computed. RESULTS: SBS measurements presented higher values than TBS (p < 0.001-0.033). Within the pretreatment groups, CEN showed the highest SBS and TBS values compared to cleaning with ISO or BUT (p < 0.001-0.040). Pretreatment with GP0.1 displayed the lowest bond strength values (p < 0.001-0.049), and mostly adhesive fractures occurred. The highest Ra values (p < 0.001) were observed for AL0.4 pretreatment. CONCLUSIONS: Pretreatment with AL0.4 and the control group mainly presented the highest bond strength values. Thermocycling had a positive effect on the bond strength. CLINICAL RELEVANCE: According to this study, 3D-printed restorations should be pretreated with AL0.4 or with visio.link before adhesive luting, regardless of their cleaning.


Assuntos
Colagem Dentária , Colagem Dentária/métodos , Propriedades de Superfície , Resinas Compostas/química , Resistência à Tração , Resistência ao Cisalhamento , Água , Cimentos de Resina/química , Teste de Materiais , Análise do Estresse Dentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...