BJUI Compass ; 5(8): 770-775, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39157160

RESUMO

Objectives: We sought to define the degree of artefact caused by prostatic urethral lift (PUL) on multiparametric-magnetic resonance imaging (mp-MRI) to determine the location, size of artefact and if the device could potentially obscure a diagnosis of prostate cancer. Methods: Ten patients were prospectively enrolled to undergo PUL for treatment of benign prostatic hyperplasia and follow-up imaging. A standard mp-MRI protocol using a 3.0 Tesla scanner was performed prior to and following Urolift insertion. Pre- and post-PUL images were compared to measure maximum artefact diameter around each implant in each MRI parameter. A transverse relaxation time weighted (T2) artefact reduction protocol was also evaluated. The location of each artefact was then compared to a separate database of 225 consecutive patients who underwent magnetic resonance guided prostate biopsies. Results: Artefact occurred around the stainless steel urethral implant component only. Mean T2 artefact maximum diameter was 7.7 mm (sd = 1.71 mm), with an artefact reduction protocol reducing this to 5.4 mm (sd = 1.43). Mean dynamic-contrast-enhancement artefact was 10 mm (sd = 2.5 mm), and mean diffusion-weighted-imaging artefact was 28.2 mm (sd = 7.8 mm). All artefacts were confined to the posterior transition zone only. In the 225 consecutive patients who had undergone magnetic resonance guided prostate biopsies, there were 55 positive biopsies with prostate cancer, with 13 cases found in the transition zones and no cancer identified solely in the posterior transitional zone. Conclusions: The stainless steel urethral component of the PUL does cause artefact, which is confined to the posterior transition zone only. PUL artefact occurs in an area of the prostate that has a very low incidence of a single focus of prostate cancer. If there is concern for prostate cancer in the posterior TZ (e.g. if every other area is clear with a high PSA), this area can undergo targeted biopsy.

2.
Clin Oral Investig ; 28(8): 450, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060664

RESUMO

OBJECTIVES: To investigate artefacts produced by different orthodontic brackets and wires in cone-beam computed tomography (CBCT) scans. MATERIALS AND METHODS: Two dental arches were made using extracted human teeth and plaster. Three pairs of acetate plates containing different brackets - metallic, ceramic, and self-ligating ceramic with NiTi clip - along with a control plate (i.e., without brackets) were prepared. Wire changes (NiTi and steel) were made during CBCT acquisitions, performed with a fixed exposure protocol. Axial slices were selected for mean gray values and standard deviation measurement in three regions of interest (buccal, lingual, and tooth). Noise and contrast-to-noise ratio (CNR) were calculated and compared among the different brackets and wires by ANOVA with a significance level of 5%. RESULTS: Overall, the buccal and tooth region were mostly affected by the metallic and self-ligating brackets, showing higher noise, and lower CNR (p < 0.05). On the other hand, less impact of ceramic brackets in the image quality was observed (p ≥ 0.05). The lingual region did not show expressive differences among the brackets and wire combinations (p ≥ 0.05). The presence of wire associated with the brackets did not worsen image quality (p ≥ 0.05). CONCLUSIONS: In conclusion, metallic and self-ligating brackets have greater artefact expression than ceramic brackets. The wire did not influence image quality. CLINICAL RELEVANCE: One should pay attention to the type of brackets when requesting a CBCT scan during treatment, as metallic and self-ligating brackets may express greater artefacts than ceramic brackets.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Braquetes Ortodônticos , Fios Ortodônticos , Humanos , Técnicas In Vitro , Cerâmica/química
3.
J Med Radiat Sci ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38941235

RESUMO

INTRODUCTION: Image quality reduction due to metallic artefacts is a significant challenge during vascular computed tomography (CT) imaging of the lower extremities in patients with hip prostheses. This study aims to analyse various reconstruction algorithms' ability to reduce metal artefacts due to two types of hip prostheses during lower extremity CT angiography examinations. METHODS: A pelvis phantom was fabricated with the insertion of a tube filled with contrast media to simulate the femoral artery, and the phantom was then CT scanned with and without hip prostheses. Multimodal images were acquired using different kilovoltage peak (kVp) settings and reconstructed with different algorithms, such as filtered back projection (FBP), iterative reconstruction (iDose4), iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR). Image quality was assessed based on image noise, signal-to-noise ratio (SNR) and Hounsfield unit (HU) deviation. RESULTS: The IMR approach significantly improved image quality compared to iDose4 and FBP. For the vascular region, O-MAR improves SNR by 5 ± 1, 23 ± 5 and 42 ± 9 for FBP, iDose4 and IMR respectively, and improves HU precision towards the baseline values by 49% and 83% for FBP and IMR, respectively. The noise reduction was 71% and 89% for FBP and IMR, and 57% for iDose4. O-MAR greatly enhances SNR corrections among the most severe artefacts, with 29 ± 1 and 43 ± 4 for FBP and IMR, compared to iDose4 by 37 ± 7. CONCLUSION: IMR combined with O-MAR could improve the CT angiography of the lower extremities of patients with a hip prosthesis.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38870528

RESUMO

OBJECTIVES: To evaluate magnetic susceptibility artefacts produced by orthodontic wires on MRI and the influence of wire properties and MRI image sequences on the magnitude of the artefact. METHODS: Arch form orthodontic wires [four stainless steels (SS), one cobalt chromium (CC) alloy, 13 titanium (Ti) alloys] were embedded in a polyester phantom, and scanned using a 1.5-T superconducting magnet scanner with an eight-channel phased-array coil. All wires were scanned with T1-weighted spin echo (SE) and gradient echo (GRE) sequences according to the American Society for Testing and Materials (ASTM) F2119-07 standard. The phantom was also scanned other eight sequences. Artefacts were measured using the ASTM F2119-07 definition and OsiriX software. Artefact volume was analyzed according to metal composition, wire length, number of wires, wire thickness, and imaging sequence as factors. RESULTS: With SE/GRE, black/white artefacts volumes from all SS wires were significantly larger than those produced by CC and Ti wires (P < 0.01). With the GRE, the black artefacts volume was highest with the SS wires. With the SE, the black artefacts volume was small, whereas white artefacts were noticeable. The cranio-caudal extent of the artefacts was significantly longer with SS wires (P < 0.01). Although a direct relationship of wire length, number of wires and wire thickness with artefact volume was noted, these factors did not influence artefact extension in the cranio-caudal direction. CONCLUSIONS: Ferromagnetic/paramagnetic orthodontic wires create artefacts due to local alteration of magnetic field homogeneity. The SS-type wires produced the largest artefacts followed by CC and Ti.

5.
J Neural Eng ; 21(4)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38941986

RESUMO

Objective.Brain-computer interfaces (BCI) have been extensively researched in controlled lab settings where the P300 event-related potential (ERP), elicited in the rapid serial visual presentation (RSVP) paradigm, has shown promising potential. However, deploying BCIs outside of laboratory settings is challenging due to the presence of contaminating artifacts that often occur as a result of activities such as talking, head movements, and body movements. These artifacts can severely contaminate the measured EEG signals and consequently impede detection of the P300 ERP. Our goal is to assess the impact of these real-world noise factors on the performance of a RSVP-BCI, specifically focusing on single-trial P300 detection.Approach.In this study, we examine the impact of movement activity on the performance of a P300-based RSVP-BCI application designed to allow users to search images at high speed. Using machine learning, we assessed P300 detection performance using both EEG data captured in optimal recording conditions (e.g. where participants were instructed to refrain from moving) and a variety of conditions where the participant intentionally produced movements to contaminate the EEG recording.Main results.The results, presented as area under the receiver operating characteristic curve (ROC-AUC) scores, provide insight into the significant impact of noise on single-trial P300 detection. Notably, there is a reduction in classifier detection accuracy when intentionally contaminated RSVP trials are used for training and testing, when compared to using non-intentionally contaminated RSVP trials.Significance.Our findings underscore the necessity of addressing and mitigating noise in EEG recordings to facilitate the use of BCIs in real-world settings, thus extending the reach of EEG technology beyond the confines of the laboratory.


Assuntos
Artefatos , Interfaces Cérebro-Computador , Eletroencefalografia , Potenciais Evocados P300 , Estimulação Luminosa , Humanos , Masculino , Feminino , Potenciais Evocados P300/fisiologia , Eletroencefalografia/métodos , Adulto , Adulto Jovem , Estimulação Luminosa/métodos , Percepção Visual/fisiologia , Aprendizado de Máquina , Movimento/fisiologia
6.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697210

RESUMO

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Assuntos
Artefatos , Impedância Elétrica , Processamento de Sinais Assistido por Computador , Tomografia , Humanos , Tomografia/métodos , Razão Sinal-Ruído , Adulto , Análise de Ondaletas , Sistema Cardiovascular , Recém-Nascido
7.
J Appl Crystallogr ; 57(Pt 2): 529-538, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38596720

RESUMO

Data collection at X-ray free electron lasers has particular experimental challenges, such as continuous sample delivery or the use of novel ultrafast high-dynamic-range gain-switching X-ray detectors. This can result in a multitude of data artefacts, which can be detrimental to accurately determining structure-factor amplitudes for serial crystallography or single-particle imaging experiments. Here, a new data-classification tool is reported that offers a variety of machine-learning algorithms to sort data trained either on manual data sorting by the user or by profile fitting the intensity distribution on the detector based on the experiment. This is integrated into an easy-to-use graphical user interface, specifically designed to support the detectors, file formats and software available at most X-ray free electron laser facilities. The highly modular design makes the tool easily expandable to comply with other X-ray sources and detectors, and the supervised learning approach enables even the novice user to sort data containing unwanted artefacts or perform routine data-analysis tasks such as hit finding during an experiment, without needing to write code.

8.
Radiography (Lond) ; 30(3): 813-820, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38513334

RESUMO

INTRODUCTION: Metal artefact reduction software (MAR) can be used to improve Computed Tomography (CT) image quality in the presence of implanted metalwork; however, this software is not effective for superficial metallic structures such as cochlear implants (CI). This study aimed to investigate whether the effectiveness of MAR software could be improved for brain scans with CI present through the use of tissue mimicking materials (TMM) placed exteriorly to the implant. METHODS: In this two-part study, a CI was positioned on the surface of water and anthropomorphic phantoms and imaged using a helical CT brain protocol. Three TMM, Superflab, Sure Thermal heat packs, and Bart's Bolus, were utilised and images were acquired to assess the resulting artefact reduction in terms of CT numbers, noise and artefact index (Aind). Changes in CTDIvol were assessed for the anthropomorphic phantom scans. RESULTS: In the water phantom, statistically significant reductions in CT number (p = 0.038) and noise (p = 0.033) were observed for Superflab, whilst the heat packs produced similar significant reductions in CT number (p < 0.001) and noise (p = 0.001) for the anthropomorphic phantom images. Aind values were significantly reduced through the use of Superflab (p = 0.009) and the heat packs (p < 0.001). No significant effects were observed for Bart's Bolus. CTDIvol increases of generally less than 5% were observed for scans with TMM in place. CONCLUSION: The additional use of TMM alongside MAR software yielded statistically significant reductions in CI induced metal artefacts on both water and anthropomorphic phantom scans with minimal dose increases. IMPLICATIONS FOR PRACTICE: The extent of metal artefacts in clinical head scans with CI in place could be significantly reduced through combined use of TMM and MAR software, consequently providing greater diagnostic confidence in the images.


Assuntos
Artefatos , Implantes Cocleares , Metais , Imagens de Fantasmas , Software , Humanos , Encéfalo/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
9.
NMR Biomed ; 37(8): e5136, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38514929

RESUMO

High acceleration factors in radial magnetic resonance fingerprinting (MRF) of the prostate lead to strong streak-like artefacts from flow in the femoral blood vessels, possibly concealing important anatomical information. Region-optimised virtual (ROVir) coils is a beamforming-based framework to create virtual coils that maximise signal in a region of interest while minimising signal in a region of interference. In this study, the potential of removing femoral flow streak artefacts in prostate MRF using ROVir coils is demonstrated in silico and in vivo. The ROVir framework was applied to radial MRF k-space data in an automated pipeline designed to maximise prostate signal while minimising signal from the femoral vessels. The method was tested in 15 asymptomatic volunteers at 3 T. The presence of streaks was visually assessed and measurements of whole prostate T1, T2 and signal-to-noise ratio (SNR) with and without streak correction were examined. In addition, a purpose-built simulation framework in which blood flow through the femoral vessels can be turned on and off was used to quantitatively evaluate ROVir's ability to suppress streaks in radial prostate MRF. In vivo it was shown that removing selected ROVir coils visibly reduces streak-like artefacts from the femoral blood flow, without increasing the reconstruction time. On average, 80% of the prostate SNR was retained. A similar reduction of streaks was also observed in silico, while the quantitative accuracy of T1 and T2 mapping was retained. In conclusion, ROVir coils efficiently suppress streaking artefacts from blood flow in radial MRF of the prostate, thereby improving the visual clarity of the images, without significant sacrifices to acquisition time, reconstruction time and accuracy of quantitative values. This is expected to help enable T1 and T2 mapping of prostate cancer in clinically viable times, aiding differentiation between prostate cancer from noncancer and healthy prostate tissue.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Próstata , Humanos , Masculino , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Adulto , Pessoa de Meia-Idade , Razão Sinal-Ruído , Simulação por Computador , Fêmur/diagnóstico por imagem , Fêmur/irrigação sanguínea
10.
Dentomaxillofac Radiol ; 53(4): 233-239, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38466923

RESUMO

OBJECTIVES: This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT). METHODS: Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test. RESULTS: Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5. CONCLUSIONS: The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. ADVANCES IN KNOWLEDGE: This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Mandíbula/diagnóstico por imagem , Titânio , Sensibilidade e Especificidade , Metais , Técnicas In Vitro
11.
J Pak Med Assoc ; 74(2): 247-251, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419221

RESUMO

Objectives: To determine the frequency and extent of artefacts in magnetic resonance imaging and/or computed tomography scans of head caused by fixed dental prosthesis. METHODS: The retrospective study was conducted at Aga Khan University Hospital from July to December 2021, and comprised magnetic resonance imaging and/or computed tomography scans from January 2015 to December 2020 of the head of individuals with existing fixed dental prosthetic work at the time of exposure. They were analysed for the presence of artefacts. The association between artefacts and the presence of fixed dental prosthesis was explored. Data was analysed using SPSS 23. RESULTS: Of the 297 images evaluated, 173 (58%) were magnetic resonance imaging scans, and 124(42%) were computed tomography scans. The most common artefacts was grade I 148(49.8%), followed by grade II 140(47.1%) and grade III 9(3%). There was no significant association between fixed dental prosthesis and the artefacts (p>0.05). Conclusion: There should be no reservations in placing fixed metal prosthesis in individuals on account of future brain scans.


Assuntos
Artefatos , Prótese Dentária , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
12.
Diagnostics (Basel) ; 14(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38337841

RESUMO

Diabetic retinopathy (DR) is the most common microvascular complication of diabetes mellitus, leading to visual impairment if left untreated. This review discusses the use of optical coherence tomography angiography (OCTA) as a diagnostic tool for the early detection and management of DR. OCTA is a fast, non-invasive, non-contact test that enables the detailed visualisation of the macular microvasculature in different plexuses. OCTA offers several advantages over fundus fluorescein angiography (FFA), notably offering quantitative data. OCTA is not without limitations, including the requirement for careful interpretation of artefacts and the limited region of interest that can be captured currently. We explore how OCTA has been instrumental in detecting early microvascular changes that precede clinical signs of DR. We also discuss the application of OCTA in the diagnosis and management of various stages of DR, including non-proliferative diabetic retinopathy (NPDR), proliferative diabetic retinopathy (PDR), diabetic macular oedema (DMO), diabetic macular ischaemia (DMI), and pre-diabetes. Finally, we discuss the future role of OCTA and how it may be used to enhance the clinical outcomes of DR.

13.
MethodsX ; 12: 102542, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38313693

RESUMO

Data-driven solutions offer great promise for improving healthcare. However, standard clinical neuroimaging data is subject to real-world imaging artefacts that can render the data unusable for computational research and quantitative neuroradiology. T1 weighted structural MRI is used in dementia research to obtain volumetric measurements from cortical and subcortical brain regions. However, clinical radiologists often prioritise T2 weighted or FLAIR scans for visual assessment. As such, T1 weighted scans are often acquired but may not be a priority, resulting in artefacts such as partial brain coverage being systematically present in memory clinic data. Here we present "MRI Crop Filling", a pipeline to replace the missing T1 data with synthetic data generated from the T2 scan, making real-world clinical T1 data usable for computational research including the latest AI innovations. Our method consists of the following steps:•Register scans: T2 and (cropped) T1.•Synthesise a new T1 using an open source deep learning tool.•Replace missing (cropped) T1 data in original T1 scan and super-resolve to improve image quality.

14.
J Med Humanit ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38407741

RESUMO

This paper argues that the newspaper Notre Journal enshrined the importance of narrative in the revolutionary psychiatry of its founder and editor, Frantz Fanon. Anchoring my analysis in the interdisciplinarity of the medical humanities, I demonstrate how care at Hôpital Blida-Joinville in colonial Algeria was mediated by the written word. I examine Fanon's physician writing and editorial texts detailing the use of narrative approaches in the clinic. As an object of care, Notre Journal's promotion of psychic healing, social actions, and engaged professional practice shaped the interactions and experiences of patients and staff. Printed and distributed to the wider institution, the newspaper created community-during an oppressive French Occupation and at the outset of the War of Independence-in addition to nurturing creativity, curiosity, solidarity, and accountability. Still, Fanon would come to recognize the limits of narrative methods amidst cultural oral traditions, illiteracy, and divergent attitudes about narrating the self.

15.
Bioengineering (Basel) ; 11(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38391634

RESUMO

PURPOSE: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. METHODS: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10-87), referred to as the "N group", and 314 KC eyes, aged 31.6 ± 10.8 (range 10-72), referred to as the "KC group", where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. RESULTS: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = -0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). CONCLUSIONS: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric.

16.
Radiat Oncol ; 19(1): 27, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38424642

RESUMO

BACKGROUND: The incorporation of magnetic resonance (MR) imaging in radiotherapy (RT) workflows improves contouring precision, yet it introduces geometrical uncertainties when registered with computed tomography (CT) scans. Synthetic CT (sCT) images could minimize these uncertainties and streamline the RT workflow. This study aims to compare the contouring capabilities of sCT images with conventional CT-based/MR-assisted RT workflows, with an emphasis on managing artefacts caused by surgical fixation devices (SFDs). METHODS: The study comprised a commissioning cohort of 100 patients with cranial tumors treated using a conventional CT-based/MR-assisted RT workflow and a validation cohort of 30 patients with grade IV glioblastomas treated using an MR-only workflow. A CE-marked artificial-intelligence-based sCT product was utilized. The delineation accuracy comparison was performed using dice similarity coefficient (DSC) and average Hausdorff distance (AHD). Artefacts within the commissioning cohort were visually inspected, classified and an estimation of thickness was derived using Hausdorff distance (HD). For the validation cohort, boolean operators were used to extract artefact volumes adjacent to the target and contrasted to the planning treatment volume. RESULTS: The combination of high DSC (0.94) and low AHD (0.04 mm) indicates equal target delineation capacity between sCT images and conventional CT scans. However, the results for organs at risk delineation were less consistent, likely because of voxel size differences between sCT images and CT scans and absence of standardized delineation routines. Artefacts observed in sCT images appeared as enhancements of cranial bone. When close to the target, they could affect its definition. Therefore, in the validation cohort the clinical target volume (CTV) was expanded towards the bone by 3.5 mm, as estimated by HD analysis. Subsequent analysis on cone-beam CT scans showed that the CTV adjustment was enough to provide acceptable target coverage. CONCLUSION: The tested sCT product performed on par with conventional CT in terms of contouring capability. Additionally, this study provides both the first comprehensive classification of metal artefacts on a sCT product and a novel method to assess the clinical impact of artefacts caused by SFDs on target delineation. This methodology encourages similar analysis for other sCT products.


Assuntos
Artefatos , Planejamento da Radioterapia Assistida por Computador , Humanos , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Sistema Nervoso Central
17.
MAGMA ; 37(2): 295-305, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38216813

RESUMO

OBJECTIVE: The excellent blood and fat suppression of stimulated echo acquisition mode (STEAM) can be combined with saturation recovery single-shot acquisition (SASHA) in a novel STEAM-SASHA sequence for right ventricular (RV) native T1 mapping. MATERIALS AND METHODS: STEAM-SASHA splits magnetization preparation over two cardiac cycles, nulling blood signal and allowing fat signal to decay. Breath-hold T1 mapping was performed in a T1 phantom and twice in 10 volunteers using STEAM-SASHA and a modified Look-Locker sequence at peak systole at 3T. T1 was measured in 3 RV regions, the septum and left ventricle (LV). RESULTS: In phantoms, MOLLI under-estimated while STEAM-SASHA over-estimated T1, on average by 3.0% and 7.0% respectively, although at typical 3T myocardial T1 (T1 > 1200 ms) STEAM-SASHA was more accurate. In volunteers, T1 was higher using STEAM-SASHA than MOLLI in the LV and septum (p = 0.03, p = 0.006, respectively), but lower in RV regions (p > 0.05). Inter-study, inter-observer and intra-observer coefficients of variation in all regions were < 15%. Blood suppression was excellent with STEAM-SASHA and noise floor effects were minimal. DISCUSSION: STEAM-SASHA provides accurate and reproducible T1 in the RV with excellent blood and fat suppression. STEAM-SASHA has potential to provide new insights into pathological changes in the RV in future studies.


Assuntos
Ventrículos do Coração , Interpretação de Imagem Assistida por Computador , Humanos , Ventrículos do Coração/diagnóstico por imagem , Miocárdio/patologia , Coração/diagnóstico por imagem , Voluntários Saudáveis , Imagens de Fantasmas , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética
18.
Radiol Case Rep ; 19(3): 1040-1045, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38226054

RESUMO

Intracranial dermoid cysts are rare slow-growing cystic lesions. They are frequently extra-axial, intra-axial localization is very rare. These benign congenital ectodermal inclusions cysts have a rare risk of rupture. Ruptured dermoid cysts can manifest with headache, epilepsy seizure, cerebral infarction, meningitis, and hydrocephaly. Neuroimaging features are quite characteristic. We report a case of a 30-year-old male who presented to the emergency room with subacute-onset headaches. CT scan and MRI show a ruptured intracranial dermoid cyst.

19.
Dentomaxillofac Radiol ; 53(2): 153-160, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38224272

RESUMO

OBJECTIVES: To evaluate the effect of the presence and the number of high-density objects in the exomass on the volume of a high-density object in cone-beam CT (CBCT). METHODS: Cylinders of cobalt-chromium (Co-Cr), titanium (Ti), and zirconium (Zi) were inserted into a polymethylmethacrylate phantom in five different combinations of number and position: 1-no cylinder; 2-one cylinder in a posterior region; 3-one cylinder in an anterior region; 4-two cylinders in posterior regions; and 5-three cylinders in anterior and posterior regions. The phantom underwent CBCT scanning using OP300 and X800 systems, with the afore mentioned cylinders of the same composition placed in the exomass and an additional high-density cylinder placed in the centre of the field of view (FOV), corresponding to the left-anterior region. The tomographic volume of the cylinder inside the FOV was measured using semi-automatic segmentation. The volumetric alteration (VA) between the segmented and physical volumes, in percentage, was compared among the experimental groups using repeated measures ANOVA and Tukey post-hoc (α = 5%). RESULTS: The factors material, combination, and their interaction affected the volume or both CBCT systems. In OP300, more cylinders in the exomass reduced the VA, mainly for Co-Cr. In X800, more cylinders in the exomass tended to increase the VA inside the FOV, except for Zi. CONCLUSIONS: In general, the presence of high-density objects in the exomass influences the VA of the object inside the FOV, although this oscillates according to object composition, number and position in the exomass, and CBCT system.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Imagens de Fantasmas
20.
NMR Biomed ; 37(3): e5060, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37937465

RESUMO

NMR spectroscopy is a mainstay of metabolic profiling approaches to investigation of physiological and pathological processes. The one-dimensional proton pulse sequences typically used in phenotyping large numbers of samples generate spectra that are rich in information but where metabolite identification is often compromised by peak overlap. Recently developed pure shift (PS) NMR spectroscopy, where all J-coupling multiplicities are removed from the spectra, has the potential to simplify the complex proton NMR spectra that arise from biosamples and hence to aid metabolite identification. Here we have evaluated two complementary approaches to spectral simplification: the HOBS (band-selective with real-time acquisition) and the PSYCHE (broadband with pseudo-2D interferogram acquisition) pulse sequences. We compare their relative sensitivities and robustness for deconvolving both urine and serum matrices. Both methods improve resolution of resonances ranging from doublets, triplets and quartets to more complex signals such as doublets of doublets and multiplets in highly overcrowded spectral regions. HOBS is the more sensitive method and takes less time to acquire in comparison with PSYCHE, but can introduce unavoidable artefacts from metabolites with strong couplings, whereas PSYCHE is more adaptable to these types of spin system, although at the expense of sensitivity. Both methods are robust and easy to implement. We also demonstrate that strong coupling artefacts contain latent connectivity information that can be used to enhance metabolite identification. Metabolite identification is a bottleneck in metabolic profiling studies. In the case of NMR, PS experiments can be included in metabolite identification workflows, providing additional capability for biomarker discovery.


Assuntos
Espectroscopia de Ressonância Magnética , Metabolômica , Líquidos Corporais/metabolismo , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/métodos , Metabolômica/métodos , Prótons , Humanos , Urina/fisiologia , Soro/metabolismo