Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-35294686

RESUMO

In the present work, halloysite nanotubes modified with gold nanoparticles (AuNPs-HNT) are successfully prepared by wet chemical method for the catalytic degradation of phenothiazine dyes (azure B (AZB) and toluidine blue O (TBO)) and also cleaner reduction of 4-(4-nitrophenyl)morpholine (4NM) in the sodium borohydride (NaBH4) media. The catalyst is formulated by modifying the HNT support with a 0.964% metal loading using the HNT supports modified with 3-aminopropyl-trimethoxysilane (APTMS) coupling agent to facilitate the anchoring sites to trap the AuNPs and to prevent their agglomeration/aggregation. The AuNPs-HNT catalyst is investigated for structural and morphological characterization to get insights about the formation of the catalyst for the effective catalytic reduction of dyes and 4NM. The microscopic studies demonstrate that AuNPs (2.75 nm) are decorated on the outer surface of HNT. The as-prepared AuNPs-HNT catalyst demonstrates AZB and TBO dye degradation efficiency up to 96% in 10 and 11 min, respectively, and catalytic reduction of 4NM to 4-morpholinoaniline (MAN) is achieved up to 97% in 11 min, in the presence of NaBH4 without the formation of any by-products. The pseudo-first-order rate constant (K1) value of the AuNPs-HNT catalyst for AZB, TBO, and 4NM were calculated to be 0.0078, 0.0055, and 0.0066 s-1, respectively. Moreover, the synthesized catalyst shows an excellent reusability with stable catalytic reduction for 7 successive cycles for both the dyes and 4NM. A plausible mechanism for the catalytic dye degradation and reduction of 4NM by AuNPs-HNT catalyst is proposed as well. The obtained results clearly indicate the potential of AuNPs-HNT as an efficient catalyst for the removal of dye contaminants from the aquatic environments and cleaner reduction of 4NM to MAN, insinuating future pharmaceutical applications.

2.
Arq. bras. med. vet. zootec. (Online) ; 72(3): 853-861, May-June, 2020. ilus, tab, graf
Artigo em Inglês | VETINDEX | ID: vti-29751

RESUMO

The present study tested a comet assay that was modified for compatibility with Giemsa staining to assess the drug genotoxicity in the peripheral blood of rats. We analysed the peripheral blood of 16 female Wistar rats (N=8 rats/group) from a control group and from a group that was treated with an intraperitoneal injection of 50mg cyclophosphamide/kg. The comet assay was carried out with modifications of the blood volume and immersion time in the lysing solution and different combinations of electrophoresis conditions (running time, voltage and current), to Giemsa staining. The lysing time and electrophoresis conditions allowed for the expression of all classes of DNA damage during the electrophoresis run, and the comets were efficiently stained with Giemsa. The technique showed high reproducibility for the DNA classes. The results demonstrate that the modified comet assay with Giemsa staining can be standardized for routine laboratory procedures using a 20µL blood sample, 3h and 30min immersions in the lysing solution and electrophoresis runs with 23 to 25 V and 310 and 360mA of electrical current. The modified comet assay with Giemsa staining that was described in the present study was standardized to be applied in the laboratory routine.(AU)


O presente estudo testou um ensaio cometa modificado para a coloração de Giemsa para avaliar a genotoxicidade de fármacos no sangue periférico de ratos. Analisou-se o sangue periférico de 16 ratas Wistar (n=8 ratas/grupo) de um grupo controle e de um grupo que foi tratado com uma injeção intraperitoneal de 50mg/kg pv. de ciclofosfamida. O ensaio cometa foi realizado com modificações do volume sanguíneo e do tempo de imersão na solução de lise, bem como com diferentes combinações de condições de eletroforese (tempo de corrida, tensão e corrente), para coloração de Giemsa. O tempo de lise e as condições de eletroforese permitiram a expressão de todas as classes de danos no DNA durante a corrida de eletroforese, e os cometas foram eficientemente corados com Giemsa. A técnica mostrou alta reprodutibilidade para as classes de DNA. Os resultados demonstram que o ensaio cometa modificado com coloração de Giemsa foi padronizado para procedimentos laboratoriais de rotina usando-se uma amostra de sangue de 20µL, 3h30min de imersão na solução de lise e eletroforese com 23 a 25 V e 310 e 360mA. O ensaio cometa modificado com coloração de Giemsa descrito foi padronizado para ser aplicado na rotina laboratorial.(AU)


Assuntos
Animais , Ratos , Coloração e Rotulagem/veterinária , Corantes Azur/toxicidade , Ensaio Cometa/veterinária , Genotoxicidade/análise , Eletroforese/veterinária , Testes de Mutagenicidade/veterinária
3.
Arq. bras. med. vet. zootec. (Online) ; 72(3): 853-861, May-June, 2020. ilus, tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1129489

RESUMO

The present study tested a comet assay that was modified for compatibility with Giemsa staining to assess the drug genotoxicity in the peripheral blood of rats. We analysed the peripheral blood of 16 female Wistar rats (N=8 rats/group) from a control group and from a group that was treated with an intraperitoneal injection of 50mg cyclophosphamide/kg. The comet assay was carried out with modifications of the blood volume and immersion time in the lysing solution and different combinations of electrophoresis conditions (running time, voltage and current), to Giemsa staining. The lysing time and electrophoresis conditions allowed for the expression of all classes of DNA damage during the electrophoresis run, and the comets were efficiently stained with Giemsa. The technique showed high reproducibility for the DNA classes. The results demonstrate that the modified comet assay with Giemsa staining can be standardized for routine laboratory procedures using a 20µL blood sample, 3h and 30min immersions in the lysing solution and electrophoresis runs with 23 to 25 V and 310 and 360mA of electrical current. The modified comet assay with Giemsa staining that was described in the present study was standardized to be applied in the laboratory routine.(AU)


O presente estudo testou um ensaio cometa modificado para a coloração de Giemsa para avaliar a genotoxicidade de fármacos no sangue periférico de ratos. Analisou-se o sangue periférico de 16 ratas Wistar (n=8 ratas/grupo) de um grupo controle e de um grupo que foi tratado com uma injeção intraperitoneal de 50mg/kg pv. de ciclofosfamida. O ensaio cometa foi realizado com modificações do volume sanguíneo e do tempo de imersão na solução de lise, bem como com diferentes combinações de condições de eletroforese (tempo de corrida, tensão e corrente), para coloração de Giemsa. O tempo de lise e as condições de eletroforese permitiram a expressão de todas as classes de danos no DNA durante a corrida de eletroforese, e os cometas foram eficientemente corados com Giemsa. A técnica mostrou alta reprodutibilidade para as classes de DNA. Os resultados demonstram que o ensaio cometa modificado com coloração de Giemsa foi padronizado para procedimentos laboratoriais de rotina usando-se uma amostra de sangue de 20µL, 3h30min de imersão na solução de lise e eletroforese com 23 a 25 V e 310 e 360mA. O ensaio cometa modificado com coloração de Giemsa descrito foi padronizado para ser aplicado na rotina laboratorial.(AU)


Assuntos
Animais , Ratos , Coloração e Rotulagem/veterinária , Corantes Azur/toxicidade , Ensaio Cometa/veterinária , Genotoxicidade/análise , Eletroforese/veterinária , Testes de Mutagenicidade/veterinária
4.
Mater Sci Eng C Mater Biol Appl ; 94: 303-309, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30423712

RESUMO

The main aim of the present study was to synthetize polyacrylamide nanoparticles and to use them as photosensitizer carriers. The new monobrominated derivatives (monobrominated neutral red and monobrominated azure B) were the photosensitizers used for antimicrobial photodynamic therapy. They were loaded into the nanocarriers and their antibacterial and oxidative activities were evaluated. The polyacrylamide nanoparticles were evaluated and prepared by inverse microemulsion polymerization. The nanoparticles obtained were characterized by size, polydispersity index, and zeta potential analysis. The Dynamic Light Scattering indicated that the diameter of the particle (z-average) was optimal, with an acceptable polydispersity index. The antibacterial activity of the polyacrylamide nanoparticles loaded with photosensitizers was evaluated against Staphylococcus aureus. Both photosensitizers loaded into the nanoparticles showed great potential as antibacterial agents since they suppressed the bacterial growth. The maximum percentage of growth reduction was 35.5% (>2 Log CFU/mL), with the monobrominated azure B loaded into the nanocarrier with 2 hydroxyethyl methacrylate against methicillin resistant S. aureus. The improved physicochemical and photophysical properties of these photosensitizers were accompanied by a significant increase in the photoantimicrobial action, in conventional-sensitive and-methicillin resistant S. aureus. The results obtained clearly suggest that polyacrylamide nanoparticles loaded with photosensitizers have great potential for further application in antimicrobial photodynamic therapy.


Assuntos
Antibacterianos/farmacologia , Nanopartículas/química , Fármacos Fotossensibilizantes/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Resinas Acrílicas/química , Antibacterianos/química , Cinética , Malonatos/química , Testes de Sensibilidade Microbiana , Oxirredução , Tamanho da Partícula , Fotoquimioterapia , Fármacos Fotossensibilizantes/química , Oxigênio Singlete/química , Espectrofotometria Ultravioleta , Eletricidade Estática
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 166: 112-120, 2016 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-27219075

RESUMO

The aggregation phenomenon of Azure B, monobrominated Azure B, Thionine and Methylene Blue was studied by UV-Visible spectrophotometry in different media as a function of dye concentration and temperature variations. The tests carried out in organic solvents allowed the identification of monomeric species of these compounds, which have not been reported in literature and have been wrongly assigned for years. The results obtained in water allowed demonstrating that different kinds of aggregates are present in this medium. In addition, the aggregation tendency of these dyes in organic solvent and aqueous media was established. Several parameters such as lipophilicity, effect of bulky substituents and interactions with media were considered to interpret the aggregation behavior of thiazine dyes.

6.
J. bras. pneumol ; J. bras. pneumol;40(3): 250-258, May-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-714689

RESUMO

Objective: To determine the reliability of a rapid hematology stain for the cytological analysis of induced sputum samples. Methods: This was a cross-sectional study comparing the standard technique (May-Grünwald-Giemsa stain) with a rapid hematology stain (Diff-Quik). Of the 50 subjects included in the study, 21 had asthma, 19 had COPD, and 10 were healthy (controls). From the induced sputum samples collected, we prepared four slides: two were stained with May-Grünwald-Giemsa, and two were stained with Diff-Quik. The slides were read independently by two trained researchers blinded to the identification of the slides. The reliability for cell counting using the two techniques was evaluated by determining the intraclass correlation coefficients (ICCs) for intraobserver and interobserver agreement. Agreement in the identification of neutrophilic and eosinophilic sputum between the observers and between the stains was evaluated with kappa statistics. Results: In our comparison of the two staining techniques, the ICCs indicated almost perfect interobserver agreement for neutrophil, eosinophil, and macrophage counts (ICC: 0.98-1.00), as well as substantial agreement for lymphocyte counts (ICC: 0.76-0.83). Intraobserver agreement was almost perfect for neutrophil, eosinophil, and macrophage counts (ICC: 0.96-0.99), whereas it was moderate to substantial for lymphocyte counts (ICC = 0.65 and 0.75 for the two observers, respectively). Interobserver agreement for the identification of eosinophilic and neutrophilic sputum using the two techniques ranged from substantial to almost perfect (kappa range: 0.91-1.00). Conclusions: The use of Diff-Quik can be considered a reliable alternative for the processing of sputum samples. .


Objetivo: Determinar a confiabilidade da coloração hematológica rápida para a análise do escarro induzido. Métodos: Estudo transversal comparando a técnica padrão (coloração May-Grünwald-Giemsa) com a coloração hematológica rápida (panótico rápido). Participaram do estudo 50 indivíduos (21 asmáticos, 19 portadores de DPOC e 10 controles). Após a coleta do escarro induzido, foram preparadas 4 lâminas, sendo 2 coradas por May-Grünwald-Giemsa e 2 por panótico rápido. As lâminas foram lidas de forma independente por dois pesquisadores capacitados para o exame de escarro induzido e cegados para a identificação das lâminas. A confiabilidade para as contagens celulares dos dois métodos foi avaliada pela determinação dos coeficientes de correlação intraclasse (CCI) para as concordâncias intraobservador e interobservador. As concordâncias na identificação de escarro neutrofílico e eosinofílico entre observadores e entre as duas colorações foram calculadas por estatística kappa. Resultados: Nas duas colorações, os CCI apontaram concordância interobservador quase perfeita para as contagens de neutrófilos, eosinófilos e macrófagos (variação do CCI: 0,98-1,00) e substancial para as contagens de linfócitos (variação do CCI: 0,76-0,83). Na análise intraobservador, a concordância foi quase perfeita para as contagens de neutrófilos, eosinófilos e macrófagos (variação do CCI: 0,96-0,99) e de moderada a substancial para as contagens de linfócitos (CCI = 0,65 e 0,75 para observadores 1 e 2, respectivamente). A concordância interobservador na identificação de escarro eosinofílico e neutrofílico para os dois métodos de ...


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Corantes , Escarro/citologia , Asma/complicações , Estudos de Casos e Controles , Estudos Transversais , Variações Dependentes do Observador , Doença Pulmonar Obstrutiva Crônica/complicações , Reprodutibilidade dos Testes , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA