Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
POCUS J ; 9(1): 51-54, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38681153

RESUMO

Ischemic colitis is the most common form of gastrointestinal ischemia 1. The diagnosis of ischemic colitis is made by clinical data and computed tomography (CT) imaging of the abdomen and pelvis 1. While colonoscopy is considered the gold standard for diagnosis, this is not performed in the emergency department (ED) 2. Few studies have been performed to describe the sonographic findings of ischemic colitis using point of care ultrasound (POCUS). We report a case that highlights the sonographic findings of ischemic colitis in a patient who had two separate visits to the ED, showcasing the utility of POCUS in making this diagnosis. POCUS can be used as a diagnostic tool for early detection of ischemic colitis leading to prompt treatment with antibiotics, CT imaging, and surgical consultation.

2.
Diagnostics (Basel) ; 14(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38611672

RESUMO

Intestinal ultrasound is a non-invasive, safe, and cost-effective technique to study the small and large intestines. In addition to conventional B-mode and color doppler imaging, new US tools have been developed in more recent years that provide auxiliary data on many GI conditions, improving the diagnosis and assessment of relevant outcomes. We have reviewed the more recent literature (from 2010 onwards) on auxiliary tools in bowel ultrasound such as elastography techniques, CEUS, SICUS, and the potential contribution by artificial intelligence (AI) to overcome current intestinal ultrasound limitations. For this scoping review, we performed an extensive literature search on PubMed and EMBASE to identify studies published until December 2023 and investigating the application of elastography techniques, CEUS, SICUS, and AI in the ultrasonographic assessment of the small and large intestines. Multiparametric intestinal ultrasound shows promising capabilities in Crohn's disease, while less is known about the role in ulcerative colitis. Despite some evidence, the CEUS role as a point-of-care examination tool for rare conditions such as intestinal GvHD and ischemic small bowel disease seems promising, possibly avoiding the need to perform further cross-sectional imaging. The use of AI in intestinal ultrasound is still anecdotical and limited to acute appendicitis.

3.
EClinicalMedicine ; 71: 102559, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38549587

RESUMO

Background: The Bowel Ultrasound Score (BUSS) accurately detects therapy-related changes by using the Simple Endoscopic Score for Crohn's disease (SES-CD) as the reference standard. We aimed to evaluate ultrasound remission as a treatment target and its prediction for long-term endoscopic remission. Methods: This single-centre prospective observational study, based at a tertiary referral centre in Milan, Italy, enrolled, between March 1, 2018, and January 31, 2021, adult patients with active CD (SES-CD >2) who were starting biologics. Colonoscopy and IUS was performed at baseline and at 12 months (mean 12.8 ± 4.2). The primary outcome was the predictive value of ultrasound remission at week 12 (BUSS ≤3.52) for long-term endoscopic remission at 12 months. The International Bowel Ultrasound Segmental Activity Score (IBUS-SAS) was also calculated and optimal cut-point to detect endoscopic remission was identified through ROC analysis. Findings: 93 patients with CD were included. Of these, 22 patients (24%) achieved endoscopic remission. Week 12 ultrasound remission predicted endoscopic remission (59% compared with 41% of the patients who were not in ultrasound remission; OR 9.93, 95% CI 3.10-31.80; p < 0.001), while week 12 calprotectin values (<50, <100, <250 µg/g) did not. Week 12 ultrasound activity was associated with failure to achieve long-term endoscopic remission (NPV 87%, PPV 54%). IBUS-SAS cut-off to discriminate endoscopic remission was 22.8 (AUC 0.906). ROC curve comparison showed no-significant difference between BUSS and IBUS-SAS (p = 0.46) for detecting endoscopic remission. Interpretation: Early ultrasound remission predicts long-term endoscopic remission, making it a valuable early treatment target for clinical practice and in clinical trials. Larger multicentre validation studies are warranted to confirm these findings. Funding: None.

4.
Dig Liver Dis ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38320914

RESUMO

BACKGROUND AND AIMS: Intestinal ultrasonography (IUS) is challenging to learn. This prospective study examined how the accuracy of IUS increases with operator experience ("learning curve") and if prior abdominal ultrasound experience facilitates the learning process. METHODS: The study included two trainees with limited abdominal ultrasound experience (< 50 exams) and two with extensive experience (> 500 exams). Each trainee performed 99 examinations and reported four IUS findings. An expert sonographer repeated the exam, and concordance (k) between the expert and trainees was assessed in three consecutive testing periods of 33 exams each. RESULTS: A progressive improvement in concordance was observed for all IUS findings from Period 1 to Period 3, overall and for both groups of trainees, although those with experience in abdominal ultrasound had faster learning curves. The minimum number of examinations required to achieve concordance with the expert operator for detecting increased bowel wall thickness was 84 and detecting bowel dilatation was 79. However, a minimum of 97 examinations was necessary to achieve concordance for detecting intra-abdominal complications, considered an advanced IUS competence. CONCLUSION: Basic competence in IUS can be acquired with relatively few examinations, while advanced competence requires more extensive training, particularly for gastroenterologists without abdominal ultrasound experience.

5.
Ann Gastroenterol ; 37(1): 54-63, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38223248

RESUMO

Background: Bowel ultrasonography (BUS) is emerging as a promising noninvasive tool for assessing disease activity in inflammatory bowel disease (IBD) patients. We evaluated the diagnostic accuracy of BUS in IBD patients against the gold standard diagnostic method, standard colonoscopy. Methods: Major databases were searched from inception to May 2023 for studies on BUS diagnostic accuracy in IBD. Outcomes of interest were pooled sensitivity, specificity, positive (PPV), and negative (NPV) predictive values. Endoscopic confirmation served as ground truth. Standard meta-analysis methods with a random-effects model and I2 statistics were applied. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Results: Twenty studies (1094 patients) were included in the final analysis. The majority (75%) of studies considered bowel wall thickness >3 mm as abnormal. Endoscopic evaluation was performed between days 3 and 180. The pooled diagnostic accuracy of BUS in IBD was 66% (95% confidence interval [CI] 58-72%; I2=78%), sensitivity was 88.6% (95%CI 85-91%; I2=77%), and specificity 86% (95%CI 81-90%; I2=95%). PPV and NPV were 94% (95%CI 93-96%; I2=25%) and 74% (95%CI 66-80%; I2=95%), respectively. On subgroup analysis, small-intestine contrast-enhanced ultrasonography (SICUS) demonstrated high sensitivity (97%, 95%CI 91-99%; I2=83%), whereas BUS exhibited high specificity (94%, 95%CI 92-96%; I2=0%) and NPV (76%, 95%CI 68-83%; I2=80.9%). Meta-regression revealed a significant relation between side-to-side anastomosis and BUS specificity (P=0.02) and NPV (P=0.004). Conclusion: The high diagnostic accuracy of BUS in detecting bowel wall inflammation suggests utilizing regular BUS as the primary modality, with subsequent consideration of SICUS if clinically warranted.

6.
Indian J Gastroenterol ; 43(1): 160-171, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37996771

RESUMO

Intestinal ultrasound is an emerging technique for diagnosing and monitoring patients with inflammatory bowel disease (IBD). It is a simple, non-invasive, inexpensive, safe and reliable tool for monitoring patients with IBD. This technique has good diagnostic accuracy in the assessment of the extent and severity of IBD and its complications. The most commonly used parameters are bowel wall thickness, color Doppler flow, bowel wall stratification and peri-bowel inflammation. Various scoring systems have been developed utilizing the above parameters to monitor patients with IBD. It is a good tool to monitor response to therapy and follow-up for post-operative recurrence. Early response on intestinal ultrasound (IUS) predicts long-term clinical remission and mucosal healing in patients with Crohn's disease. In patients with ulcerative colitis (UC), the response to IUS can be assessed as early as two weeks. Recent data has emerged to predict the response to corticosteroids and colectomy in patients with acute severe UC. Point of care IUS in the outpatient clinic is an excellent tool to follow-up patients and guide clinical decision-making and has good acceptability among patients. It is an underutilized technique in spite of its appeal and the availability of evidence. Underutilization can be attributed to the lack of awareness, expertise and training centres. This review discusses the technical details and the evidence to support the use of IUS in IBD. We aim to increase awareness and use of intestinal ultrasound and build local expertise and data.


Assuntos
Colite Ulcerativa , Doença de Crohn , Doenças Inflamatórias Intestinais , Humanos , Doenças Inflamatórias Intestinais/complicações , Intestinos , Doença de Crohn/complicações , Colite Ulcerativa/diagnóstico , Colectomia
7.
Curr Gastroenterol Rep ; 25(12): 430-439, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37979097

RESUMO

PURPOSE OF REVIEW: The incidence of celiac disease (CD) has increased over the last decades in part due to better disease awareness. Small bowel ultrasound (sb US) enables dynamic assessment of the bowel; although this topic has been addressed, the use of sb US in the diagnosis and in the follow-up of CD patients is limited to a few specialized tertiary referral centers. Herein, we aimed at summarizing the available literature on this topic to better define the potential clinical implications of sb US in CD, also through a comparison with other available diagnostic techniques. RECENT FINDINGS: According to available data, sb US can be of help in confirming or excluding CD in patients with clinical suspicion; specifically, the finding of increased gall bladder volume, free abdominal fluid and enlargement of mesenteric lymph nodes reliably and accurately predicts the diagnosis of CD, whereas the absence of bowel dilatation and increased peristalsis may exclude the diagnosis. However, the place of intestinal US in the diagnostic algorithm of CD is likely to vary depending on the probability of the disease in a given population. There are only a few studies on the role of sb US in complicated CD, even if recent reports suggest a possible clinical role. There is a lack of data on follow-up of CD patients, particularly with the aim of detecting a poor diet adherence. According to current data sb US parameters have been shown to be of value in confirming and excluding the diagnosis of CD. Prospective studies with large sample size are warranted to determine whether to include sb US in the available guidelines for CD diagnosis and monitoring.


Assuntos
Doença Celíaca , Humanos , Doença Celíaca/diagnóstico por imagem , Estudos Prospectivos , Intestino Delgado/diagnóstico por imagem , Ultrassonografia , Intestinos
8.
Pediatr Radiol ; 53(11): 2199-2207, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37589763

RESUMO

BACKGROUND: Few reports explore the frequency and factors associated with diagnostic ultrasound (US) for midgut volvulus. OBJECTIVE: To evaluate predictive factors for diagnostic US for midgut volvulus and clinical outcomes of patients with non-diagnostic US. MATERIALS AND METHODS: This retrospective study included infants imaged for midgut volvulus with US. Exams were rated as diagnostic (midgut volvulus present or absent) or non-diagnostic by a pediatric radiologist, and in cases of disagreement with the original report, an additional pediatric radiologist was the tie-breaker. For each exam, the following were recorded: age, weight, respiratory support, exam indication, sonographer experience, and gaseous dilated bowel loops on radiography. Logistic regression models with "stepwise" variable selection were used to investigate the association of diagnostic US for midgut volvulus with each of the independent variables. RESULTS: One hundred nineteen patients were imaged. US was diagnostic in 74% (88/119) of patients. In subsets of patients presenting with bilious emesis or age <28 days, US was diagnostic in 92% (22/24) and 90% (53/59), respectively. Logistic regression suggested that symptom type (bilious vs other) was the best predictor of diagnostic US (type 3 P=0.02). Out of 26 patients with available radiographs, US was diagnostic in 92% (12/13) of patients without bowel dilation on radiographs compared to 62% (8/13) of patients with bowel dilation (P=0.16). Weight, respiratory support, and sonographer experience did not differ between groups. Two sick neonates, ages 2 days and 30 days, in whom the primary clinical concern was dropping hematocrit and sepsis, respectively, had non-diagnostic ultrasounds in the setting of bowel dilation on radiography. Both were found to have midgut volvulus at surgery and both expired. CONCLUSION: US was most frequently diagnostic in patients with bilious emesis or age less than 28 days. Non-diagnostic US for midgut volvulus must prompt a predetermined follow-up strategy, such as an additional imaging study (e.g., upper GI series), particularly in a sick child, as non-diagnostic US may miss midgut volvulus.

9.
Clin Gastroenterol Hepatol ; 21(12): 3143-3151, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36521739

RESUMO

BACKGROUND & AIMS: Colonoscopy (CS) is the gold standard to assess postoperative recurrence (POR) in Crohn's disease (CD). However, CS is invasive and may be poorly tolerated by patients. The aim of this study was to prospectively assess the diagnostic accuracy of a noninvasive approach in detecting POR, using the endoscopic Rutgeerts' score (RS) as the reference standard. METHODS: Consecutive patients with CD who underwent ileo-cecal resection were prospectively enrolled in 3 referral Italian centers. Patients underwent CS and bowel ultrasound within 1 year of surgery. Uni- and multivariable analyses were used to assess the correlation between noninvasive parameters and endoscopic recurrence, defined by a RS ≥2. RESULTS: Ninety-one patients were enrolled. Sixty patients (66%) experienced endoscopic POR. The multivariable analysis identified bowel wall thickness (BWT) per 1-mm increase (odds ratio [OR], 2.43; 95% confidence interval [CI], 1.21-4.89; P = .012), the presence of mesenteric lymph nodes (OR, 15.63; 95% CI, 1.48-164.54; P = .022), and fecal calprotectin (FC) values ≥50 mcg/g (OR, 8.58; 95% CI, 2.45-29.99; P < .001) as independent predictors for endoscopic recurrence. The presence of lymph nodes or the combination of BWT ≥3 mm and FC values ≥50 mcg/g correctly classified 56% and 75% of patients, with less than 5% of patients falsely classified as having endoscopic recurrence. Conversely, the combination of BWT <3 mm and FC <50 mcg/g correctly classified 74% of patients with only 4.5% of patients falsely classified as not having endoscopic recurrence. CONCLUSIONS: A noninvasive approach combining bowel ultrasound and FC can be used with confidence for detecting POR in patients with CD without the requirement for CS.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/cirurgia , Estudos Prospectivos , Biomarcadores/análise , Colonoscopia , Colo/patologia , Recidiva , Complexo Antígeno L1 Leucocitário , Fezes/química
10.
J Crohns Colitis ; 16(10): 1637-1646, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35696668

RESUMO

BACKGROUND AND AIMS: Ultrasound elastography [USE] is an innovative, non-invasive, promptly available, ancillary technique that has been proposed in the evaluation of intestinal fibrosis as a monitorable biomarker, in terms of stiffness. The non-invasive estimate of fibrosis by USE appears appealing for dedicated physicians, in order to optimise the treatments for inflammatory bowel disease [IBD] patients [surgical vs non-surgical]. We aimed to systematically review literature evidence on ultrasound elastography in IBD patients. METHODS: For this qualitative systematic review, we searched PubMed, EMBASE, and Scopus to identify all studies, published until October 2021, investigating the application of USE in IBD patients compared with histopathological assessment. RESULTS: Overall, 12 papers published between 2011 and 2019 were included. A total of 275 IBD patients were included: 272 Crohn's disease [CD] [98.9%] and three ulcerative colitis [UC] [1.1%]. Seven [58.3%] and four [41.6%] studies investigated strain elastography [SE] and shear wave elastography [SWE], respectively; in one study [0.1%] both techniques were addressed. The histological evaluation was largely conducted on surgical specimens and in two studies endoscopic biopsies were also included. The histological assessment was semi-quantitative in all the included studies, except for two where the fibrosis was evaluated only qualitatively. In 10/12 publications USE could accurately distinguish inflammation from fibrosis in the examined bowel tracts. CONCLUSIONS: From the preliminary available data, an overall moderate-to-good accuracy of USE in detecting histological fibrosis [10/12 studies] was found. Point-shear wave elastography has been shown to perform superiorly. Further studies are needed to confirm these evidences.


Assuntos
Colite Ulcerativa , Doença de Crohn , Técnicas de Imagem por Elasticidade , Doenças Inflamatórias Intestinais , Humanos , Técnicas de Imagem por Elasticidade/métodos , Doença de Crohn/patologia , Colite Ulcerativa/patologia , Intestinos/patologia , Fibrose , Doenças Inflamatórias Intestinais/patologia
11.
Chin Clin Oncol ; 11(3): 22, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35144386

RESUMO

OBJECTIVE: We aimed, therefore, to review the current evidence on imaging modalities and carcinomas overlapping IBD. BACKGROUND: Patients affected by inflammatory bowel diseases (IBD) are at increased risk for developing both gastrointestinal and extra-intestinal cancers. The subtype of IBD, namely Crohn's disease or ulcerative colitis, the location, the activity, the extent, and the duration of the disease determine this risk. Standardized surveillance programs based on imaging techniques exist only for colorectal cancer, where colonoscopy is the milestone of early detection. Clarification is needed on whether different imaging modalities might be adopted in the algorithms for screening and diagnosis of cancers in IBD patients. METHODS: PubMed was searched up to July 2021 to identify relevant studies investigating the accuracy of imaging techniques in identifying carcinomas in IBD patients. The following text words and corresponding Medical Subject Heading/Entree terms were used: "imaging", "computed tomography", "magnetic resonance imaging", "inflammatory bowel disease", "adenocarcinoma" and "cancer". CONCLUSIONS: Currently dye-chromoendoscopy (DCE) is established as the gold standard diagnostic modality for the detection of dysplasia in IBD, with a demonstrated superiority compared to white-light endoscopy. Two main radiological patterns have been described at cross-sectional imaging for both colorectal cancer and small bowel adenocarcinoma. The first subtype is characterized by a tissue mass, while the second subtype recognizes a circumferential thickening with or without the stricturing of the lumen. The diagnostic sensitivity, specificity, and accuracy of cross-sectional imaging techniques for the detection of carcinomas in the context of IBD are largely unknown and scarcely investigated. The definition of surveillance programs based on different imaging methods is warranted.


Assuntos
Carcinoma , Neoplasias Colorretais , Doenças Inflamatórias Intestinais , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Diagnóstico por Imagem , Humanos , Doenças Inflamatórias Intestinais/complicações , Doenças Inflamatórias Intestinais/diagnóstico por imagem
12.
J Clin Med ; 11(2)2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35054047

RESUMO

International guidelines recommend a treat-to-target strategy with a close monitoring of disease activity and therapeutic response in inflammatory bowel diseases (IBD). Colonoscopy (CS) represents the current first-line procedure for evaluating disease activity in IBD. However, as it is expensive, invasive and poorly accepted by patients, CS is not appropriate for frequent and repetitive reassessments of disease activity. Recently, cross-sectional imaging techniques have been increasingly shown as reliable tools for assessing IBD activity. While computed tomography (CT) is hampered by radiation risks, routine implementation of magnetic resonance enterography (MRE) for close monitoring is limited by its costs, low availability and long examination time. Novel magnetic resonance imaging (MRI)-based techniques, such as diffusion-weighted imaging (DWI), can overcome some of these weaknesses and have been shown as valuable options for IBD monitoring. Bowel ultrasound (BUS) is a noninvasive, highly available, cheap, and well accepted procedure that has been demonstrated to be as accurate as CS and MRE for assessing and monitoring disease activity in IBD. Furthermore, as BUS can be quickly performed at the point-of-care, it allows for real-time clinical decision making. This review summarizes the current evidence on the use of cross-sectional imaging techniques as cost-effective, noninvasive and reliable alternatives to CS for monitoring patients with IBD.

13.
Inflamm Bowel Dis ; 28(Suppl 2): S67-S75, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-34984455

RESUMO

BACKGROUND: Early changes in bowel behavior during anti-tumor necrosis factor (anti-TNF) induction therapy in Crohn's disease (CD) are relatively unknown. We determined (1) the onset of changes in bowel behavior in CD patients receiving anti-TNF therapy by ultrasound and (2) the feasibility of shear wave elastography (SWE) in predicting early response to anti-TNF therapy. METHODS: Consecutive ileal or ileocolonic CD patients programmed to initiate anti-TNF therapy were enrolled. Bowel ultrasound was performed at baseline and at weeks 2, 6, and 14. Changes in bowel wall thickness, Doppler signals of the bowel wall (Limberg score), and SWE values were compared using a linear mixed model. Early response to anti-TNF therapy was based on a composite strategy of clinical and colonoscopy assessment at week 14. RESULTS: Of the 30 patients enrolled in this study, 20 patients achieved a response to anti-TNF therapy at week 14. The bowel wall thickness and SWE value of the response group showed a significant downward trend compared with the nonresponse group (P = .003 and P = .011, respectively). Bowel wall thickness, the Limberg score, and SWE values were significantly reduced as early as week 2 compared with baseline (P < .001, P < .001, and P = .003, respectively) in the response group. Baseline SWE values (21.3 ± 8.7 kPa vs 15.3 ± 4.7 kPa; P = .022) and bowel wall thickness (8.5 ± 2.3 mm vs 6.9 ± 1.5 mm; P = .027) in the nonresponse group were significantly higher than in the response group. CONCLUSIONS: This pilot study suggested that changes in bowel ultrasound behavior could be assessed as early as week 2 after starting anti-TNF therapy. Bowel ultrasound together with elasticity imaging could predict early response to anti-TNF therapy.


This pilot study suggested that changes in bowel ultrasound behavior could be assessed as early as 2 weeks after anti-tumor necrosis factor therapy in patients with Crohn's disease. Bowel ultrasound together with elasticity imaging could predict early response to anti-tumor necrosis factor therapy.


Assuntos
Doença de Crohn , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/tratamento farmacológico , Doença de Crohn/patologia , Humanos , Intestinos/diagnóstico por imagem , Intestinos/patologia , Projetos Piloto , Inibidores do Fator de Necrose Tumoral , Ultrassonografia
14.
Gastroenterol. hepatol. (Ed. impr.) ; 45(1): 40-46, Ene. 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-204127

RESUMO

Objetivo: La ecografía intestinal se considera una alternativa para la evaluación de la recurrencia posquirúrgica (RPQ) de la enfermedad de Crohn. El objetivo de este estudio es evaluar la correlación entre los hallazgos ecográficos y endoscópicos.Métodos: Se recogieron de forma retrospectiva los datos de pacientes con enfermedad de Crohn y resección ileocecal en los que se había realizado una colonoscopia y una ecografía intestinal para la detección de RPQ. La RPQ se evaluó empleando el índice de Rutgeerts (IR). Los hallazgos ecográficos analizados fueron el grosor de la pared intestinal, la hiperemia parietal por Doppler, la desestructuración del patrón de capas y la proliferación fibrograsa.Resultados: Se incluyó a un total de 31 pacientes, 15 (48,4%) sin recurrencia (IR? mm vs. 5,68mm; p?<0,001). La hiperemia también se asoció de forma significativa con la recurrencia endoscópica (p?=?0,03). Para el grosor parietal se obtuvo un área bajo la curva ROC (AUC) del 92,9% y, con punto de corte en 3,4mm, la sensibilidad fue del 100% y la especificidad del 86,6%. Al comparar con los biomarcadores principales (calprotectina fecal y PCR sérica) se obtuvo un AUC superior para el grosor (72,3% y 72,3% vs. 92,9%).Conclusiones: En nuestra experiencia, la ecografía tiene una alta rentabilidad diagnóstica para la detección de RPQ y puede considerarse en muchas ocasiones como una alternativa válida y no invasiva a la ileocolonoscopia.


Objective: Intestinal ultrasound is considered to be a valid alternative for the evaluation of post-operative recurrence (POR) of Crohn's disease. The aim of this study is to assess the correlation between ultrasound and endoscopic findings.Methods: Patients with Crohn's disease were retrospectively recruited who had undergone ileocecal resection, and for whom a colonoscopy and intestinal ultrasound had been performed for the detection of POR. Recurrence was assessed using the Rutgeerts score (RS). The ultrasound findings analysed were bowel wall thickness (BWT), parietal hyperaemia using power Doppler, loss of layer pattern and mesenteric fat hypertrophy.Results: A total of 31 patients were included, of which 15 (48.4%) had no POR (RS<2b) and 16 (51.6%) had POR (RS≥2b). A statistically significant association was identified between BWT and the presence of endoscopic recurrence (a mean of 2.75mm vs. 5.68mm, P>0.001). There was also a statistically significant difference in hyperaemia between the 2groups (P=0.03). For wall thickness, an area under the ROC curve (AUC) of 92.9% was obtained, and with a cut-off point of 3.4mm, a sensitivity of 100% and specificity of 86.6%. When comparing with the most frequent biomarkers (fecal calprotectin and serum CRP), a higher AUC was obtained for wall thickness (72.3% and 72.3% vs. 92.9%).Conclusions: In our experience, ultrasound has high diagnostic efficacy in the detection of POR and can be considered a valid non-invasive alternative to endoscopy.


Assuntos
Humanos , Endoscopia , Correlação de Dados , Ultrassonografia , Doença de Crohn , Recidiva , Estudos Retrospectivos , Gastroenterologia , Colonoscopia
15.
Gastroenterol Hepatol ; 45(1): 40-46, 2022 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33746025

RESUMO

OBJECTIVE: Intestinal ultrasound is considered to be a valid alternative for the evaluation of post-operative recurrence (POR) of Crohn's disease. The aim of this study is to assess the correlation between ultrasound and endoscopic findings. METHODS: Patients with Crohn's disease were retrospectively recruited who had undergone ileocecal resection, and for whom a colonoscopy and intestinal ultrasound had been performed for the detection of POR. Recurrence was assessed using the Rutgeerts score (RS). The ultrasound findings analysed were bowel wall thickness (BWT), parietal hyperaemia using power Doppler, loss of layer pattern and mesenteric fat hypertrophy. RESULTS: A total of 31 patients were included, of which 15 (48.4%) had no POR (RS<2b) and 16 (51.6%) had POR (RS≥2b). A statistically significant association was identified between BWT and the presence of endoscopic recurrence (a mean of 2.75mm vs. 5.68mm, P>0.001). There was also a statistically significant difference in hyperaemia between the 2groups (P=0.03). For wall thickness, an area under the ROC curve (AUC) of 92.9% was obtained, and with a cut-off point of 3.4mm, a sensitivity of 100% and specificity of 86.6%. When comparing with the most frequent biomarkers (fecal calprotectin and serum CRP), a higher AUC was obtained for wall thickness (72.3% and 72.3% vs. 92.9%). CONCLUSIONS: In our experience, ultrasound has high diagnostic efficacy in the detection of POR and can be considered a valid non-invasive alternative to endoscopy.


Assuntos
Colonoscopia , Doença de Crohn/diagnóstico por imagem , Ultrassonografia , Biomarcadores/análise , Proteína C-Reativa/análise , Doença de Crohn/cirurgia , Fezes/química , Humanos , Hiperemia/diagnóstico por imagem , Íleo/diagnóstico por imagem , Intestinos/irrigação sanguínea , Intestinos/diagnóstico por imagem , Complexo Antígeno L1 Leucocitário/análise , Pessoa de Meia-Idade , Curva ROC , Recidiva , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Ultrasound ; 30(4): 333-337, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36969532

RESUMO

Introduction: Appendicitis is a common cause for emergency operations in the western part of the world, mostly affecting children and young adults. Ultrasound in well-trained hands is an effective imaging tool in making this diagnosis; however, this does not come without its challenges and potential complications. Case report: This is a case of a 19-year-old male with one-day history of severe pain in the right iliac fossa; blood results showed raised inflammatory markers. Ultrasound revealed a large abnormal loop of bowel containing heterogeneously echogenic contents, and two large appendicoliths at the base and fundus, with the presence of free fluid in the right iliac fossa and oedema in the adjacent mesentery. Laparoscopic appendectomy confirmed the presence of severe appendicitis with generalised peritonitis and appendicolith. Histology revealed gangrenous appendicitis with perforation in two places. Discussion: This case demonstrates that making a diagnosis of an inflamed appendix alone on ultrasound is not enough, and conducting a detailed assessment of the inflamed appendix and its surrounding anatomy is essential so that all the associated findings can be reported to aid in the patient management, reduce hospital stay and improve overall diagnosis and prognosis.

17.
Life (Basel) ; 11(7)2021 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-34357022

RESUMO

Bowel ultrasound (BUS) is a non-invasive and accurate technique for assessing activity, extension of disease, and complications in inflammatory bowel diseases. The main advantages of BUS are its safety, reproducibility, and low costs. Ancillary technologies of BUS (i.e., color Doppler and wave elastography) could broaden the diagnostic power of BUS, allowing one to distinguish between inflammation and fibrosis. Considering the costs and invasiveness of colonoscopy and magnetic resonance, BUS appears as a fast, safe, and accurate technique. The objective measures of disease allow one to make clinical decisions, such as optimization, switch, or swap of therapy. Previous studies reported a sensitivity and a specificity of more than 90% compared to endoscopy and magnetic resonance. Lastly, transperineal ultrasound (TPUS) is a promising approach for the evaluation of perianal disease in Crohn's disease (CD) and disease activity in patients with ulcerative proctitis or pouchitis. Bowel ultrasound is being incorporated in the algorithm of managing inflammatory bowel diseases. Transmural healing evaluated through ultrasonography is emerging as a complementary target for disease treatment. In this review, we aimed to summarize and discuss the current evidence on BUS in the management of inflammatory bowel diseases and to address the challenges of a full validation of this technique.

18.
Therap Adv Gastroenterol ; 14: 17562848211030050, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34345250

RESUMO

BACKGROUND AND AIM: The aim was to assess non-invasive factors among clinical features, laboratory, and bowel ultrasound (BUS) characteristics and to develop a scoring system to predict endoscopic activities for ulcerative colitis (UC) patients. METHODS: We performed a retrospective study collecting UC patients between January 2015 to September 2020. Logistic regression was performed to predict moderate-to-severe endoscopic activities, defined as endoscopic Mayo score ⩾2. Model performance was described with discrimination and calibration ability and validated by internal and external methods. RESULTS: A total of 103 and 29 patients were enrolled in the modeling and validation groups, respectively. Stool frequency ⩾5 times/day, hematochezia, erythrocyte sedimentation rate (ESR), and colonic wall flow in BUS were included into two predictive models for endoscopic activities, both with good discrimination ability [Area under curve (AUC) 0.879 and 0.882, p < 0.001] and a sensitivity of 76.7% and specificity of 92.3%, which showed an adequate calibration ability by using the Hosmer-Lemeshow test (p = 0.14 and 0.07). The external validation displayed consistent results with the above mentioned. Nomograms were also established for these models. CONCLUSION: We developed predictive models for endoscopic disease activities by using noninvasive factors based on stool frequency, hematochezia, ESR, and colonic wall blood flow in BUS. These models performed well in the internal and external validation.

19.
Life (Basel) ; 11(7)2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34201630

RESUMO

Intestinal ultrasound (IUS) has gained popularity as a first line technique for the diagnosis and monitoring of patients with inflammatory bowel diseases (IBD) due to its many advantages. It is a non-invasive imaging technique with non-ionizing radiation exposure. It can be easily performed not only by radiologists but also by trained gastroenterologists at outpatient clinics. In addition, the cost of IUS equipment is low when compared with other imaging techniques. IUS is an accurate technique to detect inflammatory lesions and complications in the bowel in patients with suspected or already known Crohn's disease (CD). Recent evidence indicates that IUS is a convenient and accurate technique to assess extension and activity in the colon in patients with ulcerative colitis (UC), and can be a non-invasive alternative to endoscopy. In patients with IBD, several non-specific pathological ultrasonographic signs can be identified: bowel wall thickening, alteration of the bowel wall echo-pattern, loss of bowel stratification, increased vascularization, decreased bowel peristalsis, fibro-fatty proliferation, enlarged lymph nodes, and/or abdominal free fluid. Considering the transmural CD inflammation, CD complications such as presence of strictures, fistulae, or abscesses can be detected. In patients with UC, where inflammation is limited to mucosa, luminal inflammatory ultrasonographic changes are similar to those of CD. As the technique is related to the operator's experience, adequate IUS training, performance in daily practice, and a generalized use of standardized parameters will help to increase its reproducibility.

20.
Diagnostics (Basel) ; 11(4)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808245

RESUMO

Small bowel obstruction (SBO) is a common condition requiring urgent attention that may involve surgical treatment. Imaging is essential for the diagnosis and characterization of SBO because the clinical presentation and results of laboratory tests may be nonspecific. Ultrasound is an excellent initial imaging modality for assisting physicians in the rapid and accurate diagnosis of a variety of pathologies to expedite management. In the case of SBO diagnosis, ultrasound has an overall sensitivity of 92% (95% CI: 89-95%) and specificity of 93% (95% CI: 85-97%); the aim of this review is to examine the criteria for the diagnosis of SBO by ultrasound, which can be divided into diagnostic and staging criteria. The diagnostic criteria include the presence of dilated loops and abnormal peristalsis, while the staging criteria are represented by parietal and valvulae conniventes alterations and by the presence of free extraluminal fluid. Ultrasound has reasonably high accuracy compared to computed tomography (CT) scanning and may substantially decrease the time to diagnosis; moreover, ultrasound is also widely used in the monitoring and follow-up of patients undergoing conservative treatment, allowing the assessment of loop distension and the resumption of peristalsis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...