Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.415
Filtrar
1.
Eur J Radiol ; 177: 111558, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38964225

RESUMO

PURPOSE: Cone-Beam CT (CBCT) is well established in orofacial diagnostic imaging and is currently expanding into musculoskeletal applications. This systematic review sought to update the knowledge base on radiation dose comparisons between imaging modalities in MSK imaging and consider how research studies have reported dose measures. METHODS: This review utilised a database search and an online literature tool. Studies with potential relevance were screened then before full text review, each performed by two independent reviewers, with a third independent reviewer available for conflicts. Data was extracted using a bespoke tool created within the literature tool. RESULTS: 21 studies were included in the review which compared CBCT with MSCT (13), conventional radiography (1), or both (7). 19 studies concluded that CBCT provided a reduced radiation dose when compared with MSCT: the factor of reduction ranging from 1.71 to 50 with an average of 12. Studies comparing CBCT to DR found DR to have an average dose reduction of 4.55. CONCLUSIONS: The claims that CBCT produces a lower radiation dose than MSCT is borne out with most studies confirming doses less than half that of MSCT. Fewer studies include DR as a comparator but confirm that CBCT results in a higher effective dose on average, with scope for CBCT to provide an equivalent radiation dose. This review highlighted a need for consistency in methodology when conducting studies which compare radiation dose across different technologies. Potential solutions lie outside the scope of this review, likely requiring multi-discipline approach to ensure a cohesive outcome.

2.
Sci Rep ; 14(1): 15278, 2024 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961162

RESUMO

To determine the diagnostic yield of cone beam computed tomography (CBCT) compared with 3 T magnetic resonance imaging (MRI) for the evaluation of subchondral insufficiency fractures of the knee. Consecutive patients with subchondral insufficiency fractures of the knee examined by 3 T MRI and CBCT of the femoral condyles were reviewed. Two experienced raters graded the lesion severity on 3 T MRI and CBCT images: grade 1: no signs of a subchondral bone lesion; grade 2: subchondral trabecular fracture or cystic changes, but without infraction of the subchondral bone plate; grade 3: collapse of the subchondral bone plate. Ratings were repeated after six weeks to determine reliability. In addition, the bone lesion size was measured as elliptical area (mm2) and compared between CBCT and T1-weighted MRI sequences. Among 30 patients included (43.3% women; mean age: 60.9 ± 12.8 years; body mass index (BMI) 29.0 ± 12.8 kg/m2), the medial femoral condyle was affected in 21/30 patients (70%). The grading of subchondral lesions between MRI and CBCT did not match in 12 cases (40%). Based on MRI images, an underestimation (i.e., undergrading) compared with CBCT was observed in nine cases (30%), whereas overgrading occurred in three cases (10%). Compared to CBCT, routine T1-weighted 3 T sequences significantly overestimated osseus defect zones in sagittal (84.7 ± 68.9 mm2 vs. 35.9 ± 38.2 mm2, p < 0.01, Cohen's d = 1.14) and coronal orientation (53.1 ± 24.0 mm2 vs. 22.0 ± 15.2 mm2, p < 0.01, Cohen's d = 1.23). The reproducibility of the grading determined by intra- and inter-rater agreement was very high in MRI (intra-class correlation coefficient (ICC) 0.78 and 0.90, respectively) and CBCT (ICC 0.96 and 0.96, respectively). In patients with subchondral insufficiency fractures of the knee, the use of CBCT revealed discrepancies in lesion grading compared with MRI. These findings are clinically relevant, as precise determination of subchondral bone plate integrity may influence the decision about conservative or surgical treatment. CBCT represents our imaging modality of choice for grading the lesion and assessing subchondral bone plate integrity. MRI remains the gold standard modality to detect especially early stages.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento por Ressonância Magnética , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Idoso , Fraturas de Estresse/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Reprodutibilidade dos Testes
3.
Skeletal Radiol ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38969781

RESUMO

Computed tomography (CT) is a common modality employed for musculoskeletal imaging. Conventional CT techniques are useful for the assessment of trauma in detection, characterization and surgical planning of complex fractures. CT arthrography can depict internal derangement lesions and impact medical decision making of orthopedic providers. In oncology, CT can have a role in the characterization of bone tumors and may elucidate soft tissue mineralization patterns. Several advances in CT technology have led to a variety of acquisition techniques with distinct clinical applications. These include four-dimensional CT, which allows examination of joints during motion; cone-beam CT, which allows examination during physiological weight-bearing conditions; dual-energy CT, which allows material decomposition useful in musculoskeletal deposition disorders (e.g., gout) and bone marrow edema detection; and photon-counting CT, which provides increased spatial resolution, decreased radiation, and material decomposition compared to standard multi-detector CT systems due to its ability to directly translate X-ray photon energies into electrical signals. Advanced acquisition techniques provide higher spatial resolution scans capable of enhanced bony microarchitecture and bone mineral density assessment. Together, these CT acquisition techniques will continue to play a substantial role in the practices of orthopedics, rheumatology, metabolic bone, oncology, and interventional radiology.

4.
Cureus ; 16(6): e62026, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989337

RESUMO

Background Understanding root canal anatomy variations, particularly C-shaped canals, is crucial for successful endodontic treatment. This study used clinical and radiographic methods to assess the prevalence and characteristics of C-shaped canals in mandibular second molars in Western Maharashtra. Materials and methods This prospective study was conducted in the western region of Maharashtra, India. The samples included patients requiring endodontic treatment for mandibular second molars. Clinical evaluation was conducted using a surgical endodontic microscope and cone beam computed tomography (CBCT) imaging. Inclusion and exclusion criteria ensured the selection of a focused and homogeneous sample. Data analysis included assessment of unilateral/bilateral occurrence, canal distribution, and cross-sectional characteristics. Results Out of 200 mandibular second molars, 7.5% exhibited C-shaped root canals, with no significant gender differences. Canal distribution varied across coronal, middle, and apical levels, with prevalent configurations being C1, C2, C3, and C4. No significant differences were observed in canal distribution based on root levels. No significant gender differences were found in the presence of grooves on the root surfaces. Conclusion This study provides valuable insights into the prevalence and characteristics of C-shaped canals in mandibular second molars in Western Maharashtra. Further research into histological and genetic aspects can enhance our understanding, leading to improved treatment strategies for complex root canal anatomy variations.

5.
Phys Med ; 124: 103426, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38986263

RESUMO

PURPOSE: To analyze the image quality of a novel, state-of-the art platform for CBCT image-guided spine surgery, focusing particularly on the dose-effectiveness compared with conventional CT (the gold standard for postoperative assessment). METHODS: The ClarifEye platform (Philips Healthcare) with integrated augmented-reality surgical navigation, has been compared with a GE Revolution CT (GE Healthcare). The 3D spatial resolution (TTF) and noise (NPS) were evaluated considering relevant feature contrasts (200-900 HU) and background noise for differently sized patients (200-300 mm water-equivalent diameter). These measures were used to determine the noise equivalent quanta (NEQ) and observer model detectability. RESULTS: The CBCT system exhibited a linear response with 50% TTF at 5.7 cycles/cm (10% TTF at 9.2 cycles/cm), and the axial noise power peaking at about 3.6 cycles/cm (average frequency of 4.1 cycles/cm). The noise magnitude and texture differed markedly compared to iteratively reconstructed CT images (GE ASiR-V). The CBCT system had 26% lower detectability for a high-frequency task (related to edge detection) compared with CT images reconstructed using the Bone kernel combined with ASiR-V 50%. Likewise, it had 18% lower detectability for low- and mid-frequency tasks compared with CT images reconstructed using the Standard kernel. This difference translates to 50%-80% higher CBCT imaging doses required to match the CT image quality. CONCLUSIONS: The ClarifEye platform demonstrates intraoperative CBCT-imaging capabilities that under certain circumstances are comparable with conventional CT. However, due to limited dose-effectiveness, a trade-off between timeliness and radiation exposure must be considered if end-of-procedure CBCT is to replace postoperative CT.

6.
Clin Oral Investig ; 28(7): 406, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38949690

RESUMO

OBJECTIVES: This study aimed to develop and validate a predictive nomogram for diagnosing radicular grooves (RG) in maxillary lateral incisors (MLIs), integrating demographic information, anatomical measurements, and Cone Beam Computed Tomography (CBCT) data to diagnose the RG in MLIs based on the clinical observation before resorting to the CBCT scan. MATERIALS AND METHODS: A retrospective cohort of orthodontic patients from the School and Hospital of Stomatology, Wuhan University, was analyzed, including demographic characteristics, photographic anatomical assessments, and CBCT diagnoses. The cohort was divided into development and validation groups. Univariate and multivariate logistic regression analyses identified significant predictors of RG, which informed the development of a nomogram. This nomogram's performance was validated using receiver operating characteristic analysis. RESULTS: The study included 381 patients (64.3% female) and evaluated 760 MLIs, with RG present in 26.25% of MLIs. The nomogram incorporated four significant anatomical predictors of RG presence, demonstrating substantial predictive efficacy with an area under the curve of 0.75 in the development cohort and 0.71 in the validation cohort. CONCLUSIONS: A nomogram for the diagnosis of RG in MLIs was successfully developed. This tool offers a practical checklist of anatomical predictors to improve the diagnostic process in clinical practice. CLINICAL RELEVANCE: The developed nomogram provides a novel, evidence-based tool to enhance the detection and treatment planning of MLIs with RG in diagnostic and therapeutic strategies.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Incisivo , Maxila , Nomogramas , Humanos , Feminino , Masculino , Incisivo/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico/métodos , Adolescente , Maxila/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Criança , China
7.
Cureus ; 16(5): e61402, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38947703

RESUMO

The prognosis of luxation injuries of primary teeth is often unpredictable. A two-year-old girl presented with a displaced left primary maxillary anterior tooth diagnosed as severe intrusive luxation. On radiographic examination, it was noticed to be impinging on the underlying permanent tooth bud. The tooth was extracted, and periodic follow-ups were emphasized until the successor tooth erupted. However, after eight years, the patient followed up with a chief complaint of an unerupted permanent maxillary anterior tooth. Cone-beam computed tomography (CBCT) revealed a combination of anomalies in the crown and root of the maxillary anterior tooth. After a wait-and-observe regime for six months, the incisal third of the crown erupted. At eight years and eight months, the tooth developed a periapical abscess which was treated endodontically and restored. At nine years and three months, the tooth is asymptomatic till date. The present case report highlights the consequences of intrusive luxation injuries to the primary teeth and the need for a multidisciplinary team approach in the management of complications of dental trauma along with meticulous long-term follow-ups.

8.
Int Endod J ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38976489

RESUMO

AIM: To evaluate whether supplemental information from CBCT changed long-term prognosis for teeth with external cervical resorption (ECR) compared to periapical (PA) images. Furthermore, to assess predictive findings in PA images and evaluate which findings in CBCT affected the long-term prognosis of teeth with ECR. METHODOLOGY: One hundred and ninty-four patients, mean age 41.2, range 13-81, having 244 teeth with ECR were included. An initial long-term prognosis determined either good or poor was established based on intraoral images. Afterwards, the patients underwent CBCT, and final long-term prognosis was decided. From the PA images and CBCT, ECR using Heithersay's classification system, pulp involvement and extension of ECR was assessed. In CBCT, the number of surface lesion(s) was additionally assessed. Descriptive statistics evaluated changes in long-term prognosis after CBCT. Logistic regression analyses tested if findings in PA images and CBCT affected the long-term prognosis. RESULTS: Based on CBCT, out of 244 teeth the long-term prognosis was assessed to be poor for 173 (70.9%) teeth and good for 71 (29.1%) teeth. The long-term prognosis changed in 76 (31.1%) teeth after CBCT; 5 (2.0%) changed from poor to good, and 71 (29%) changed from good to poor long-term prognosis. In 81 (33.2%) teeth the H-class increased, and in 10 (4.1%) teeth the H-class decreased after assessing CBCT. In 70 (28.7%) teeth, there was a change from no pulp involvement to involvement of the pulp after CBCT; eight (3.3%) teeth changed in the opposite direction. H-class 2 and 4 in PA images significantly increased the probability for a change in long-term prognosis compared to an H-class 3 (p < .05). H-class 4, pulp involvement, ECR in the oral 1/3 of the root, and more than two surface lesions seen in CBCT significantly influenced a poor long-term prognosis (p < .05). CONCLUSIONS: Supplemental information from CBCT changed long-term prognosis in almost one third of teeth with ECR. In most cases, the long-term prognosis changed from good to poor. H-class 3 in PA images had a significant influence on change in long-term prognosis. Several findings in CBCT influenced a poor long-term prognosis.

9.
J Oral Rehabil ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38978295

RESUMO

BACKGROUND: Some orthodontic devices used in children share similar design principles to appliances used to treat obstructive sleep apnoea in adults. As well as treating malocclusion, orthodontic appliances used in children may therefore also have effects on the upper airway. OBJECTIVE: A review of the literature to assess the effects of orthodontic treatment on the upper airway dimensions in children assessed on CBCT. MATERIALS AND METHODS: Following registration of the protocol (PROSPERO CRD42023439056), a systematic electronic search of published studies was performed using several databases (PubMed; Scopus, Web of Science and Science Direct) in accordance with the PRISMA guidelines. Inclusion criteria were as follows: age under 18 years, orthodontic treatment with any appliance, a control group who received no treatment or a non-active alternative treatment and airway measurement using CBCT. RoB-2 and ROBINS-I tools were used to assess risk of bias and quality of the evidence. RESULTS: In total, 341 studies were identified following the initial search. Title and abstract screening resulted in 45 studies for further full-text analysis. On completion of the screening process, a total of 23 studies met the inclusion criteria. Study interventions included functional appliances (10 studies), rapid maxillary expansion (RME) (9 studies), reverse-pull headgear (1 study) and 4 premolar dental extractions (3 studies). The included studies had moderate to high risk of bias, and the quality of evidence was low. CONCLUSION: The scientific evidence shows that functional appliances are associated with significant improvements in both upper airway volume and constriction when used in children however, the effects on the nasal cavity are limited. RME was associated with a significant increase in nasal cavity and nasopharyngeal dimensions, but not the upper pharyngeal airway. Neither reverse-pull headgear nor dental extractions were associated with any change in airway dimensions; however, the evidence is limited. Functional appliances may reduce the severity of obstructive sleep apnoea (OSA) in children.

10.
Cureus ; 16(6): e62285, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39006571

RESUMO

OBJECTIVES: To evaluate and compare the efficacy of XP-endo Finisher R (FKG Dentaire, Le Locle, Neuchatel, Switzerland), EDDY (VDW Dental, Munich, Germany), and passive ultrasonic irrigation (PUI) as supplementary steps following the D-RaCe retreatment file system (FKG Dentaire) in the removal of root canal obturation material using cone beam CT. MATERIALS AND METHODS: A total of 45 two-rooted permanent maxillary first premolars were selected. Following access preparation, cleaning, and shaping with Hero Shaper (Micro Mega, Besançon, BFC, France) rotary file up to 25/04%, thermoplasticized obturation was performed with TotalFill BC sealer (FKG Dentaire) and gutta-percha. The specimens were subjected to routine retreatment using the D-RaCe retreatment file system. Cone beam computed tomography (CBCT) and volumetric analysis were performed before and after this procedure. The samples were divided into group A (XP-endo Finisher R: n=15), group B (EDDY: n=15), and group C (PUI: n=15). Finally, a third CBCT was taken and a volumetric analysis was done. Statistical analysis was done using SPSS Statistics version 26.0 (IBM Corp., Armonk, NY, USA). RESULTS: The lowest mean residual volume of obturation material was seen with XP-endo Finisher R (1.6 mm3), followed by PUI (1.7 mm3). The EDDY showed the least efficiency in complete debridement of the root canals (3.6 mm3). This difference in values was statistically significant. CONCLUSION: The XP-endo Finisher R and PUI showed superior performance than EDDY in the removal of remaining obturation material from the root canal system after retreatment with the D-RaCe retreatment file system. However, none of the systems were able to completely remove the root canal obturation materials.

11.
Cureus ; 16(6): e62127, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38993416

RESUMO

Splitting a molar means removing or separating the root and the accompanying crown portion. Hemisection of a damaged tooth aids in preserving the tooth structure and the existing alveolar bone surrounding the preserved root while also enabling the installation of a fixed prosthesis. This case report defines hemisection as an effective modality for preserving carious mandibular first molars with periodontal and periapical pathology.

12.
Heliyon ; 10(12): e32513, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38994088

RESUMO

Introduction: The reconstruction of both extra- and intra-oral soft tissue defects, particularly in restoring the morphology of the lip and the corners of the mouth, has posed a significant challenge for surgeons. Inappropriate methods often lead to maxillofacial deformity which then causes psychological and functional problems. This study aimed to address the challenge of reconstructing extensive and complex maxillofacial soft tissue defects, mainly focusing on the lip, the corners of the mouth, and the surrounding areas. Materials and methods: We developed a reconstruction approach by combining the 3dMDface System (3dMD) with the cone beam computed tomography (CBCT). Firstly, with the extra-oral incision line, we evaluated the shape and the size of the extra-oral defect with 3dMD digitally. Then we used the corresponding maxillary and mandible tooth positions to record the intra-oral defect, which was then converted to digital images by combining 3dMD and CBCT. The islands of the anterolateral thigh perforator flap were then designed after the locations of the perforators were detected with Doppler ultrasonography. Results: A clinical case diagnosed as dermatofibrosarcoma protuberans was presented to illustrate the approach. The patient's tumor resection and the size of multiple defects were measured and simulated via the virtual surgery system. A three-island perforator flap from the descending branch of the lateral femoral circumflex artery was designed accurately. Two weeks postoperatively, the flap was healed as anticipated and the patient was satisfied with the profile. Conclusion: The combination of the 3dMD and CBCT technologies improves the accuracy and fitness of extra- and intra-oral soft tissue reconstruction.

13.
Int J Comput Dent ; 0(0): 0, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39011634

RESUMO

AIM: Condylar hyperplasia (CH) is a progressive and deforming disease that modifies anatomy of the temporomandibular joint (TMJ) structures. This study aims to correlate the metabolic bone activity of the condyle measured by SPECT with the volumetry anatomic information from the condyle, fossa and joint space provided by CT images, in patients with CH in active and inactive forms. MATERIALS AND METHODS: A cross-sectional comparative study was performed with a set of 116 images from healthy and diagnosed CH patients to compare volumetric measures of the TMJ. Images were acquired through a bone tissue mask using a three-dimensional DICOM reconstruction for SPECT/CT and CBCT images and the Threshold option for segmentation with standardized values for each tissue on the HU scale. RESULTS: there are differences (p<0.01), with greater condylar volume on the affected side in patients with active CH compared to passive CH. The volume of the glenoid cavity shows no differences in either form of CH (p>0.05), however, there were differences for the volume of the joint space on the affected right side of hemimandibular elongation (HE) in the active form. The volume of the mandibular condyle on the affected side in CH cases were larger in HE cases in active and inactive form (p<0.01) compared to healthy patients. Similar results were presented for the glenoid cavity and joint space. CONCLUSIONS: Volumetric anatomical evaluation of TMJ structures, as well as information on condylar metabolic activity, can be obtained from SPECT/CT. The study shows a greater condylar volume on the affected side of the CH compared to the contralateral side, but there are more significant differences in the active than in the inactive form.

14.
Cureus ; 16(5): e59835, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38846201

RESUMO

The palatogingival groove is a developmental anomaly on the palatal surface of the maxillary anterior teeth. The shallow groove, often less than 1 mm, is challenging to diagnose, particularly in radiographic examinations. Such grooves are mistaken for root fractures. In this case study, we explore the prevalence, types, radiological appearances, and treatment options of type I shallow palatogingival grooves encountered in cone beam computed tomography.

15.
Int Orthod ; 22(3): 100890, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38838434

RESUMO

BACKGROUND: The maxillary permanent canine is one of the most frequently impacted teeth, which often requires multidisciplinary management. A common complication of canine impaction is root resorption of the adjacent dentition. The aim of this retrospective study was to report the prevalence of root resorption of maxillary incisors adjacent to impacted maxillary canines from small volume CBCT images by trained clinicians. A secondary objective was to report the location and severity of root resorption. MATERIAL AND METHODS: CBCT images of patients with impacted maxillary canines (unilateral and bilateral) who attended a joint orthodontic/surgical multidisciplinary clinic were screened. Descriptive statistics were used to investigate associations of patient characteristics and presence of root resorption. Generalized estimating equations (GEE) logistic regression model were used to identify predictors of root resorption. RESULTS: In all, 148 impacted maxillary canines (122 patients) were analysed. The majority of patients were under 18 years of age (71.6%) with impacted canines present in more females (68.2%) than males (31.8%). Maxillary lateral incisors showed the highest prevalence of root resorption (38.5%). The apical region was the most common location of resorption for lateral incisors (20.9%) with a variable degree of severity evident: slight (10.1%), moderate (15.6%), and severe (12.8%). Although no significant predictors of root resorption were identified, a weak association was evident for age and root development. CONCLUSIONS: In this cohort of patients, the roots of maxillary lateral incisors are most likely to suffer from root resorption in the presence of an impacted maxillary canine. Clinicians should consider the extent, location and severity of resorption of adjacent teeth when planning treatment decisions and mechanics in cases of impacted maxillary canines.

16.
Fa Yi Xue Za Zhi ; 40(2): 143-148, 2024 Apr 25.
Artigo em Inglês, Chinês | MEDLINE | ID: mdl-38847028

RESUMO

OBJECTIVES: To estimate adolescents and children age using stepwise regression and machine learning methods based on the pulp and tooth volumes of the left maxillary central incisor and cuspid on cone beam computed tomography (CBCT) images, and to compare and analyze the estimation results. METHODS: A total of 498 Shanghai Han adolescents and children CBCT images of the oral and maxillofacial regions were collected. The pulp and tooth volumes of the left maxillary central incisor and cuspid were measured and calculated. Three machine learning algorithms (K-nearest neighbor, ridge regression, and decision tree) and stepwise regression were used to establish four age estimation models. The coefficient of determination, mean error, root mean square error, mean square error and mean absolute error were computed and compared. A correlation heatmap was drawn to visualize and the monotonic relationship between parameters was visually analyzed. RESULTS: The K-nearest neighbor model (R2=0.779) and the ridge regression model (R2=0.729) outperformed stepwise regression (R2=0.617), while the decision tree model (R2=0.494) showed poor fitting. The correlation heatmap demonstrated a monotonically negative correlation between age and the parameters including pulp volume, the ratio of pulp volume to hard tissue volume, and the ratio of pulp volume to tooth volume. CONCLUSIONS: Pulp volume and pulp volume proportion are closely related to age. The application of CBCT-based machine learning methods can provide more accurate age estimation results, which lays a foundation for further CBCT-based deep learning dental age estimation research.


Assuntos
Determinação da Idade pelos Dentes , Tomografia Computadorizada de Feixe Cônico , Polpa Dentária , Aprendizado de Máquina , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Adolescente , Criança , Determinação da Idade pelos Dentes/métodos , Polpa Dentária/diagnóstico por imagem , Dente/diagnóstico por imagem , China , Incisivo/diagnóstico por imagem , Incisivo/anatomia & histologia , Feminino , Masculino , Algoritmos
17.
Int J Paediatr Dent ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38937920

RESUMO

BACKGROUND AND AIM: To compare two cone beam computed tomography (CBCT) analysis techniques for measuring tertiary dentin (TD) volume, density, and root length increase, after indirect pulp therapy (IPT) in young permanent teeth with conventional periapical radiographs. DESIGN: Comparative study design: Sixty-nine CBCT scans were taken initially (T1) and after 1 year (T2) of IPT. New CBCT analysis technique A, standardization, segmentation, and registration of T1 and T2 scans were performed using ITK-SNAP and 3D Slicer CMF to measure TD volume (mm3), density (gray-level intensity), and root length increase (mm). In the traditional CBCT analysis technique B, analyses were conducted using the In-Vivo software to calculate TD thickness (mm), radiodensity (HU%), and root length increase (mm). Paired t-test and the intraclass correlation coefficient were calculated to compare and assess the reliability of all techniques. RESULTS: No significant difference between the two techniques existed in the measurement of TD mineral density (Mean [SD]:A = 22.4 [15.4]; B = 24.4 [15.4]; p = .47). Technique A resulted in significantly higher root length increase values (Mean [SD]: A = 1.3 [0.6]; B = 1.1 [0.5]; p = .03). The two techniques showed acceptable reliability levels (0.76-0.99). CONCLUSION: CBCT analysis techniques yielded similar findings for mineral density. The new CBCT volumetric analysis technique, although more laborious, produced higher values for root length increase, and allowed for measurement of dentin volume.

18.
Acta Med Philipp ; 58(1): 90-97, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38939849

RESUMO

Objective: To determine the effect of the impacted position of the maxillary canine on the root resorption of the adjacent incisor using Cone-beam Computed Tomography (CBCT) imaging. Methods: This was an analytic quantitative study. The research sample determined CBCT images of treatment patients at the Orthodontic Specialist Policlinic in Dental Hospital of Airlangga University over a three-year period and secondary data taken from Pramita Laboratory. CBCT photos that met the inclusion criteria, including mesially impacted canine or close to central or lateral incisors with completely formed anatomy were then analyzed. Multiple linear regression was used to determine x-axis, y-axis, z-axis position of the impacted canine on the severity of root resorption of the adjacent incisor, and the effect of impacted canines on all axes simultaneously on the severity of root resorption of the adjacent incisors. Results: The position of the impacted canine in the x-axis and z-axis planes had a significant influence on the root resorption of the adjacent incisor. Meanwhile, impacted canine from the y-axis plane showed non-significant influence on the root resorption. Conclusion: The position of the impacted canine when viewed in all planes of the tooth axis has a significant effect on the severity of root resorption of the adjacent incisor.

19.
Sci Rep ; 14(1): 14470, 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914766

RESUMO

This study employed a commercial software velocity to perform deformable registration and dose calculation on deformed CT images, aiming to assess the accuracy of dose delivery during the radiotherapy for lung cancers. A total of 20 patients with lung cancer were enrolled in this study. Adaptive CT (ACT) was generated by deformed the planning CT (pCT) to the CBCT of initial radiotherapy fraction, followed by contour propagation and dose recalculation. There was not significant difference between volumes of GTV and CTV calculated from the ACT and pCT. However, significant differences in dice similarity coefficient (DSC) and coverage ratio (CR) between GTV and CTV were observed, with lower values for GTV volumes below 15 cc. The mean differences in dose corresponding to 95% of the GTV, GTV-P, CTV, and CTV-P between ACT and pCT were - 0.32%, 4.52%, 2.17%, and 4.71%, respectively. For the dose corresponding to 99%, the discrepancies were - 0.18%, 8.35%, 1.92%, and 24.96%, respectively. These differences in dose primarily appeared at the edges of the target areas. Notably, a significant enhancement of dose corresponding to 1 cc for spinal cord was observed in ACT, compared with pCT. There was no statistical difference in the mean dose of lungs and heart. In general, for lung cancer patients, anatomical motion may result in both CTV and GTV moving outside the original irradiation region. The dose difference within the original target area was small, but the difference in the planning target area was considerable.


Assuntos
Neoplasias Pulmonares , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Software , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada de Feixe Cônico/métodos
20.
Bioengineering (Basel) ; 11(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38927807

RESUMO

Ameloblastoma (AM), periapical cyst (PC), and chronic suppurative osteomyelitis (CSO) are prevalent maxillofacial diseases with similar imaging characteristics but different treatments, thus making preoperative differential diagnosis crucial. Existing deep learning methods for diagnosis often require manual delineation in tagging the regions of interest (ROIs), which triggers some challenges in practical application. We propose a new model of Wavelet Extraction and Fusion Module with Vision Transformer (WaveletFusion-ViT) for automatic diagnosis using CBCT panoramic images. In this study, 539 samples containing healthy (n = 154), AM (n = 181), PC (n = 102), and CSO (n = 102) were acquired by CBCT for classification, with an additional 2000 healthy samples for pre-training the domain-adaptive network (DAN). The WaveletFusion-ViT model was initialized with pre-trained weights obtained from the DAN and further trained using semi-supervised learning (SSL) methods. After five-fold cross-validation, the model achieved average sensitivity, specificity, accuracy, and AUC scores of 79.60%, 94.48%, 91.47%, and 0.942, respectively. Remarkably, our method achieved 91.47% accuracy using less than 20% labeled samples, surpassing the fully supervised approach's accuracy of 89.05%. Despite these promising results, this study's limitations include a low number of CSO cases and a relatively lower accuracy for this condition, which should be addressed in future research. This research is regarded as an innovative approach as it deviates from the fully supervised learning paradigm typically employed in previous studies. The WaveletFusion-ViT model effectively combines SSL methods to effectively diagnose three types of CBCT panoramic images using only a small portion of labeled data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...