Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.658
Filtrar
1.
Int J Mol Sci ; 25(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38731918

RESUMO

In the age of information technology and the additional computational search tools and software available, this systematic review aimed to identify potential therapeutic targets for obesity, evaluated in silico and subsequently validated in vivo. The systematic review was initially guided by the research question "What therapeutic targets have been used in in silico analysis for the treatment of obesity?" and structured based on the acronym PECo (P, problem; E, exposure; Co, context). The systematic review protocol was formulated and registered in PROSPERO (CRD42022353808) in accordance with the Preferred Reporting Items Checklist for Systematic Review and Meta-Analysis Protocols (PRISMA-P), and the PRISMA was followed for the systematic review. The studies were selected according to the eligibility criteria, aligned with PECo, in the following databases: PubMed, ScienceDirect, Scopus, Web of Science, BVS, and EMBASE. The search strategy yielded 1142 articles, from which, based on the evaluation criteria, 12 were included in the systematic review. Only seven these articles allowed the identification of both in silico and in vivo reassessed therapeutic targets. Among these targets, five were exclusively experimental, one was exclusively theoretical, and one of the targets presented an experimental portion and a portion obtained by modeling. The predominant methodology used was molecular docking and the most studied target was Human Pancreatic Lipase (HPL) (n = 4). The lack of methodological details resulted in more than 50% of the papers being categorized with an "unclear risk of bias" across eight out of the eleven evaluated criteria. From the current systematic review, it seems evident that integrating in silico methodologies into studies of potential drug targets for the exploration of new therapeutic agents provides an important tool, given the ongoing challenges in controlling obesity.


Assuntos
Simulação por Computador , Obesidade , Humanos , Obesidade/tratamento farmacológico , Obesidade/metabolismo , Animais , Simulação de Acoplamento Molecular , Fármacos Antiobesidade/farmacologia , Fármacos Antiobesidade/uso terapêutico , Lipase/metabolismo , Lipase/antagonistas & inibidores , Terapia de Alvo Molecular/métodos
2.
JSES Int ; 8(3): 646-653, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38707552

RESUMO

Background: Various methods of two or three-dimensional (3D) corrective osteotomy for cubitus varus deformity have been reported. However, whether 3D correction of cubitus varus deformity is necessary is controversial because of technical difficulties and surgical complications. This study introduced 3D simulations and printing technology for corrective osteotomy against cubitus varus deformities. Moreover, recent studies on the application of these technologies were reviewed. Methods: The amount of 3D deformity was calculated based on the difference in 3D shape between the affected side and the contralateral normal side. Patient-matched instruments were created to perform the actual surgery as simulated. Further, a 3D corrective osteotomy was performed using patient-matched instruments for cubitus varus deformity in pediatric and adolescent patients. The humerus-elbow-wrist angle, tilting angle, and elbow ranges of motion were evaluated. Results: Humerus-elbow-wrist angle and tilting angle were corrected from -21° to 14° and from 30° to 43°, respectively, in the pediatric patient and from -18° to 10° and from 20° to 40°, respectively, in the adolescent patient. The elbow flexion and extension angles changed from 130° to 140° and from 20° to 10°, respectively, in the pediatric patient and from 120° to 130° and from 15° to 0°, respectively, in the adolescent patient. Conclusion: The 3D computer simulations and the use of patient-matched instruments for cubitus varus deformity are reliable and can facilitate an accurate and safe correction. These technologies can simplify the complexity of 3D surgical procedures and contribute to the standardization of treatment for cubitus varus deformity.

3.
Neurology (Chic) ; 3(1)2024.
Artigo em Inglês | MEDLINE | ID: mdl-38699565

RESUMO

Alzheimer's disease (AD) is the most common neurodegenerative dementia worldwide. AD is a multifactorial disease that causes a progressive decline in memory and function precipitated by toxic beta-amyloid (Aß) proteins, a key player in AD pathology. In 2022, 6.5 million Americans lived with AD, costing the nation $321billion. The standard of care for AD treatment includes acetylcholinesterase inhibitors (AchEIs), NMDA receptor antagonists, and monoclonal antibodies (mAbs). However, these methods are either: 1) ineffective in improving cognition, 2) unable to change disease progression, 3) limited in the number of therapeutic targets, 4) prone to cause severe side effects (brain swelling, microhemorrhages with mAb, and bradycardia and syncope with AchEIs), 5) unable to effectively cross the blood-brain barrier, and 6) lack of understanding of the aging process on the disease. mAbs are available to lower Aß, but the difficulties of reducing the levels of the toxic Aß proteins in the brain without triggering brain swelling or microhemorrhages associated with mAbs make the risk-benefit profile of mAbs unclear. A novel multitarget, effective, and safe non-invasive approach utilizing Repeated Electromagnetic Field Stimulation (REMFS) lowers Aß levels in human neurons and memory areas, prevents neuronal death, stops disease progression, and improves memory without causing brain edema or bleeds in AD mice. This REMFS treatment has not been developed for humans because current EMF devices have poor penetration depth and inhomogeneous E-field distribution in the brain. Here, we discussed the biology of these effects in neurons and the design of optimal devices to treat AD.

4.
Heart ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38754969

RESUMO

BACKGROUND: The practical application of 'virtual' (computed) fractional flow reserve (vFFR) based on invasive coronary angiogram (ICA) images is unknown. The objective of this cohort study was to investigate the potential of vFFR to guide the management of unselected patients undergoing ICA. The hypothesis was that it changes management in >10% of cases. METHODS: vFFR was computed using the Sheffield VIRTUheart system, at five hospitals in the North of England, on 'all-comers' undergoing ICA for non-ST-elevation myocardial infarction acute coronary syndrome (ACS) and chronic coronary syndrome (CCS). The cardiologists' management plan (optimal medical therapy, percutaneous coronary intervention (PCI), coronary artery bypass surgery or 'more information required') and confidence level were recorded after ICA, and again after vFFR disclosure. RESULTS: 517 patients were screened; 320 were recruited: 208 with ACS and 112 with CCS. The median vFFR was 0.82 (0.70-0.91). vFFR disclosure did not change the mean number of significantly stenosed vessels per patient (1.16 (±0.96) visually and 1.18 (±0.92) with vFFR (p=0.79)). A change in intended management following vFFR disclosure occurred in 22% of all patients; in the ACS cohort, there was a 62% increase in the number planned for medical management, and in the CCS cohort, there was a 31% increase in the number planned for PCI. In all patients, vFFR disclosure increased physician confidence from 8 of 10 (7.33-9) to 9 of 10 (8-10) (p<0.001). CONCLUSION: The addition of vFFR to ICA changed intended management strategy in 22% of patients, provided a detailed and specific 'all-in-one' anatomical and physiological assessment of coronary artery disease, and was accompanied by augmentation of the operator's confidence in the treatment strategy.

5.
Int J Biol Macromol ; 270(Pt 2): 132383, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38754667

RESUMO

Halogenated Organic Phosphate Esters (OPEs) are commonly found in plasticizers and flame retardants. However, they are one kind of persistent contaminants that can pose a significant threat to human health and ecosystem as new environmental estrogen. In this study, two representative halogenated OPEs, tris(1,3-dichloro-2-propyl) phosphate (TDCP) and tris(2,3-dibromopropyl) phosphate (TDBP), were selected as experimental subjects to investigate their interaction with human serum albumin (HSA). Despite having similar structures, the two ligands exhibited contrasting effects on enzyme activity of HSA, TDCP inhibiting enzyme activity and TDBP activating it. Furthermore, both TDCP and TDBP could bind to HSA at site I, interacted with Arg222 and other residues, and made the conformation of HSA unfolded. Thermodynamic parameters indicated the main driving forces between TDBP and HSA were hydrogen bonding and van der Waals forces, while TDCP was mainly hydrophobic force. Molecular simulations found that more hydrogen bonds of HSA-TDBP formed during the binding process, and the larger charge area of TDBP than TDCP could partially account for the differences observed in their binding abilities to HSA. Notably, the cytotoxicity of TDBP/TDCP was inversely proportional to their binding ability to HSA, implying a new method for determining the cytotoxicity of halogenated OPEs in vitro.

6.
Cureus ; 16(3): e55626, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586680

RESUMO

Prolonged times to tracheal extubation are associated with adverse patient and economic outcomes. We simulated awakening patients from sevoflurane after long-duration surgery at 2% end-tidal concentration, 1.0 minimum alveolar concentration (MAC) in a 40-year-old. Our end-of-surgery target was 0.5 MAC, the Michigan Awareness Control Study's threshold for intraoperative alerts. Consider an anesthetist who uses a 1 liter/minute gas flow until surgery ends. During surgical closure, the inspired sevoflurane concentration is reduced from 2.05% to 0.62% (i.e., MAC-awake). The estimated time to reach 0.5 MAC is 28 minutes. From a previous study, 28 minutes exceeded ≥95% of surgical closure times for all 244 distinct surgical procedures (N=23,343 cases). Alternatively, the anesthetist uses 8 liters/minute gas flow with the vaporizer at MAC-awake for 1.8 minutes, which reduces the end-tidal concentration to 0.5 MAC. The anesthetist then increases the vaporizer to keep end-tidal 0.5 MAC until the surgery ends. An additional simulation shows that, compared with simulated end-tidal agent feedback control, this approach consumed 0.45 mL extra agent. Simulation results are the same for an 80-year-old patient. The extra 0.45 mL has a global warming potential comparable to driving 26 seconds at 40 kilometers (25 miles) per hour, comparable to route modification to avoid potential roadway hazards.

7.
Temperature (Austin) ; 11(1): 92-106, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577294

RESUMO

Thermal safety guidelines with upper thresholds aim to protect athletes' health, yet evidence-based sport-specific thresholds remain unestablished. Experimenting with athletes in severely hot conditions raises ethical concerns, so we used a thermo-physiological model to validate the thresholds of guidelines for outdoor sports. First, the reproducibility of the joint system thermoregulation model (JOS-3) of core temperature has been validated for 18 sports experiments (n = 213) and 11 general exercise experiments (n = 121) using the Bland - Altman analysis. Then, core temperatures were predicted using the JOS-3 in conditions corresponding to the upper thresholds, and if the 90th-99.7th percentile core temperature value (corresponding to 0.3%-10% of the participants) exceeded 40°C, the thresholds were judged as potentially hazardous. Finally, we proposed revisions for sports with potentially hazardous thresholds. As a result, the JOS-3 could simulate core temperature increases in most experiments (27/29) for six sports and general exercises with an accuracy of 0.5°C. The current upper thresholds for marathons, triathlons, and football are potentially hazardous. Suggested revisions, based on specified percentiles, include: Football: revise from wet bulb globe temperature (WBGT) 32°C to 29-31°C or not revise. Marathon: revise from WBGT 28°C to 24-27°C. Triathlon: revise from WBGT 32.2°C to 23-26°C. If conducting sports events under the revised upper thresholds proves difficult, taking measures for a possible high incidence of heat illness becomes crucial, such as placing additional medical resources, assisting heat acclimatization and cooling strategies for participants, and rule changes such as shorter match times and increased breaks.

8.
HNO ; 2024 Apr 08.
Artigo em Alemão | MEDLINE | ID: mdl-38587661

RESUMO

BACKGROUND: The size of the human cochlear, measured by the diameter of the basal turn, varies between 7 and 11 mm. For hearing rehabilitation with cochlear implants (CI), the size of the cochlear influences the individual frequency map and the choice of electrode length. OTOPLAN® (CAScination AG [Bern, Switzerland] in cooperation with MED-EL [Innsbruck, Austria]) is a software tool with CE marking for clinical applications in CI treatment which allows for precise pre-planning based on cochlear size. This literature review aims to analyze all published data on the application of OTOPLAN®. MATERIALS AND METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied to identify relevant studies published in the PubMed search engine between January 2015 and February 2023 using the search terms "otoplan" [title/abstract] OR "anatomy-based fitting" [title/abstract] OR "otological software tool" [title/abstract] OR "computed tomography-based software AND cochlear" [title/abstract]. RESULTS: The systematic review of the literature identified 32 studies on clinical use of OTOPLAN® in CI treatment. Most studies were reported from Germany (7 out of 32), followed by Italy (5), Saudi Arabia (4), the USA (4), and Belgium (3); 2 studies each were from Austria and China, and 1 study from France, India, Norway, South Korea, and Switzerland. In the majority of studies (22), OTOPLAN® was used to assess cochlear size, followed by visualizing the electrode position using postoperative images (5), three-dimensional segmentation of temporal bone structures (4), planning the electrode insertion trajectory (3), creating a patient-specific frequency map (3), planning of a safe drilling path through the facial recess (3), and measuring of temporal bone structures (1). CONCLUSION: To date, OTOPLAN® is the only DICOM viewer with CE marking in the CI field that can process pre-, intra-, and postoperative images in the abovementioned applications.

9.
Prog Orthod ; 25(1): 13, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584176

RESUMO

OBJECTIVES: To evaluate the accuracy of a semi-automatic 3D digital setup process in predicting the orthodontic treatment outcome achieved by labial fixed appliances. SUBJECTS AND METHODS: Twenty-five adult patients (18 to 24 years old) with class I malocclusion and moderate crowding were prospectively enrolled and received treatment on both jaws through the straight-wire technique. Prior to treatment commencement, a semi-automatic digital setup simulating the predicted treatment outcome was performed for each patient through Orthoanalyzer software (3Shape®, Copenhagen, Denmark) to obtain the prediction model. This was compared to the final outcome model through 3D superimposition methods. Metric variables and inspection of color-coded distance maps were used to detect how accurately the digital setup predicts the actual treatment outcome. RESULTS: The mean absolute distances (MAD) between the superimposed dental arches of the predicted and the final models were: 0.77 ± 0.13 mm following superimposition on the palate, 0.52 ± 0.06 mm following superimposition on the maxillary dental arch, and 0.55 ± 0.15 mm following superimposition on the mandibular dental arch. The MAD at the palatal reference area was 0.09 ± 0.04 mm. Visualization of color-coded distance maps indicated that the digital setup accurately predicted the final teeth position in a few cases. Almost half of the cases had posteriorly wider upper and lower dental arches and palatally/lingually positioned or inclined anterior teeth, whereas the rest still showed errors within 2-3 mm, distributed over the entire dental arches with no distinct pattern. CONCLUSIONS: The accuracy of semi-automatic prediction of the labial fixed appliance treatment outcome in Class I cases with moderate crowding is not yet sufficient. While average measures showed deviations less than 1 mm, examination of individual color-coded distance maps revealed significant disparities between the simulated and the actual results.


Assuntos
Má Oclusão Classe I de Angle , Má Oclusão , Dente , Adulto , Humanos , Adolescente , Adulto Jovem , Estudos Prospectivos , Má Oclusão/terapia , Má Oclusão Classe I de Angle/terapia , Aparelhos Ortodônticos Fixos , Aparelhos Ortodônticos
10.
Elife ; 122024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38598284

RESUMO

Computer models of the human ventricular cardiomyocyte action potential (AP) have reached a level of detail and maturity that has led to an increasing number of applications in the pharmaceutical sector. However, interfacing the models with experimental data can become a significant computational burden. To mitigate the computational burden, the present study introduces a neural network (NN) that emulates the AP for given maximum conductances of selected ion channels, pumps, and exchangers. Its applicability in pharmacological studies was tested on synthetic and experimental data. The NN emulator potentially enables massive speed-ups compared to regular simulations and the forward problem (find drugged AP for pharmacological parameters defined as scaling factors of control maximum conductances) on synthetic data could be solved with average root-mean-square errors (RMSE) of 0.47 mV in normal APs and of 14.5 mV in abnormal APs exhibiting early afterdepolarizations (72.5% of the emulated APs were alining with the abnormality, and the substantial majority of the remaining APs demonstrated pronounced proximity). This demonstrates not only very fast and mostly very accurate AP emulations but also the capability of accounting for discontinuities, a major advantage over existing emulation strategies. Furthermore, the inverse problem (find pharmacological parameters for control and drugged APs through optimization) on synthetic data could be solved with high accuracy shown by a maximum RMSE of 0.22 in the estimated pharmacological parameters. However, notable mismatches were observed between pharmacological parameters estimated from experimental data and distributions obtained from the Comprehensive in vitro Proarrhythmia Assay initiative. This reveals larger inaccuracies which can be attributed particularly to the fact that small tissue preparations were studied while the emulator was trained on single cardiomyocyte data. Overall, our study highlights the potential of NN emulators as powerful tool for an increased efficiency in future quantitative systems pharmacology studies.


Assuntos
Miócitos Cardíacos , Redes Neurais de Computação , Humanos , Potenciais de Ação , Simulação por Computador , Bioensaio
11.
Int J Implant Dent ; 10(1): 19, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656614

RESUMO

PURPOSE: Dental implants have been successfully implemented as a treatment for tooth loss. However, peri-implantitis, an inflammatory reaction owing to microbial deposition around the implant, can lead to implant failure. So, it is necessary to treat peri-implantitis. Therefore, this numerical study is aimed at investigating conditions for treating peri-implantitis. METHODS: Photothermal therapy, a laser treatment method, utilizes photothermal effect, in which light is converted to heat. This technique has advantage of selectively curing inflamed tissues by increasing their temperature. Accordingly, herein, photothermal effect on peri-implantitis is studied through numerical analysis with using Arrhenius damage integral and Arrhenius thermal damage ratio. RESULTS: Through numerical analysis on peri-implantitis treatment, we explored temperature changes under varied laser settings (laser power, radius, irradiation time). We obtained the temperature distribution on interface of artificial tooth root and inflammation and determined whether temperature exceeds or does not exceed 47℃ to know which laser power affects alveolar bone indirectly. We defined the Arrhenius thermal damage ratio as a variable and determined that the maximum laser power that does not exceed 47℃ at the AA' line is 1.0 W. Additionally, we found that the value of the Arrhenius thermal damage ratio is 0.26 for a laser irradiation time of 100 s and 0.50 for 500 s. CONCLUSION: The result of this numerical study indicates that the Arrhenius thermal damage ratio can be used as a standard for determining the treatment conditions to help assisted laser treatment for peri-implantitis in each numerical analysis scenario.


Assuntos
Peri-Implantite , Terapia Fototérmica , Peri-Implantite/terapia , Peri-Implantite/radioterapia , Humanos , Terapia Fototérmica/métodos , Temperatura , Implantes Dentários/efeitos adversos , Lasers
12.
J Pers Med ; 14(4)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38673033

RESUMO

Using mathematical models of physiological systems in medicine has allowed for the development of diagnostic, treatment, and medical educational tools. However, their complexity restricts, in most cases, their application for predictive, preventive, and personalized purposes. Although there are strategies that reduce the complexity of applying models based on fitting techniques, most of them are focused on a single instant of time, neglecting the effect of the system's temporal evolution. The objective of this research was to introduce a dynamic fitting strategy for physiological models with an extensive array of parameters and a constrained amount of experimental data. The proposed strategy focused on obtaining better predictions based on the temporal trends in the system's parameters and being capable of predicting future states. The study utilized a cardiorespiratory model as a case study. Experimental data from a longitudinal study of healthy adult subjects undergoing aerobic exercise were used for fitting and validation. The model predictions obtained in a steady state using the proposed strategy and the traditional single-fit approach were compared. The most successful outcomes were primarily linked to the proposed strategy, exhibiting better overall results regarding accuracy and behavior than the traditional population fitting approach at a single instant in time. The results evidenced the usefulness of the dynamic fitting strategy, highlighting its use for predictive, preventive, and personalized applications.

13.
Comput Methods Programs Biomed ; 250: 108172, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38669718

RESUMO

BACKGROUND AND OBJECTIVE: Degenerative diseases of the spine have a negative impact on the quality of life of patients. This study presents the results of numerical modelling of the mechanical behaviour of the lumbar spine with patient-specific conditions at physiological loads. This paper aims to numerically study the influence of degenerative changes in the spine and the presence of an endoprosthesis on the creation of conditions for tissue regeneration. METHODS: A numerical model of the mechanical behaviour of lumbar spine at healthy and after total disc replacement under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behaviour of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid. The nutritional pathways of the intervertebral disc in cases of healthy and osteoporotic bone tissues were predicted based on the analysis of the simulation results according to the mechanobiological principles. RESULTS: Simulation of total disc replacement showed that osseointegration of the artificial disc plates occurs only in healthy bone tissue. With total disc replacement in a patient with osteoporosis, there is an area of increased risk of bone resorption in the near-contact area, approximately 1 mm wide, around the fixators. Dynamic loads may improve the osseointegration of the implant in pathological conditions of the bone tissue. CONCLUSIONS: The results obtained in the case of healthy spine and osteoporotic bone tissues correspond to the experimental data on biomechanics and possible methods of IVD regeneration from the position of mechanobiological principles. The results obtained with an artificial disc (with keel-type fixation) showed that the use of this type of endoprosthesis in healthy bone tissues allows to reproduce the function of the natural intervertebral disc and does not contribute to the development of neoplastic processes. In the case of an artificial disc with osteoporosis of bone tissues, there is a zone with increased risk of tissue resorption and development of neoplastic processes in the area near the contact of the implant attachment. This circumstance can be compensated by increasing the loading level.


Assuntos
Simulação por Computador , Disco Intervertebral , Vértebras Lombares , Substituição Total de Disco , Humanos , Vértebras Lombares/cirurgia , Disco Intervertebral/cirurgia , Disco Intervertebral/fisiopatologia , Regeneração , Fenômenos Biomecânicos , Osteoporose/fisiopatologia , Osseointegração
14.
J Med Econ ; 27(1): 746-753, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38686394

RESUMO

OBJECTIVE: This analysis estimated the outcomes of triennial blood-based colorectal cancer (CRC) screening at various adherence, including perfect adherence, compared with triennial multi-target stool DNA (mt-sDNA) screening at the reported real-world adherence rate. METHODS: The validated CRC-AIM model simulated a US cohort of average-risk individuals receiving triennial screening with mt-sDNA or blood-based test from ages 45 to 75 years. Modeled specificity and sensitivity were based on reported data. Adherence was set at a real-world rate of 65.6% for mt-sDNA and at 65.6%, relative 10% incremental increases from 65.6%, or 100% for the blood-based test. Costs of mt-sDNA and the blood-based test were based on prices for clinically available tests ($508.87 and $895, respectively). Value-based pricing was estimated at a willingness-to-pay threshold of $100,000. RESULTS: Both tests resulted in life-years gained (LYG), reduced CRC cases, and reduced deaths versus no screening. With adherence for mt-sDNA set at 65.6% and for blood-based test set at 100%, mt-sDNA resulted in 30% more LYG, 52% more averted CRC cases, and 32% more averted CRC deaths. At reported sensitivity and specificity rates, mt-sDNA at 65.6% adherence dominates (is more effective and less costly) the blood-based test at any adherence. There was no price at which triennial screening with the blood-based test at any adherence was cost-effective compared with mt-sDNA at 65.6% adherence. CONCLUSIONS: Triennial screening with mt-sDNA resulted in better clinical outcomes at a lower cost compared with the modeled blood-based test even at perfect adherence, supporting application of blood-based tests only as a secondary screening option.


Blood-based colorectal cancer screening has lower diagnostic accuracy, lower clinical and health outcomes, and is more expensive than mt-sDNA, even with perfect blood-based screening participation. Although better than no screening at all, blood-based testing is unlikely to exceed performance of stool-based assessment unless a blood-based test is able to meaningfully detect precancerous growths.


Assuntos
Neoplasias Colorretais , Análise Custo-Benefício , Detecção Precoce de Câncer , Sangue Oculto , Humanos , Neoplasias Colorretais/diagnóstico , Pessoa de Meia-Idade , Idoso , Masculino , Feminino , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/economia , Fezes/química , Cooperação do Paciente , Sensibilidade e Especificidade , Anos de Vida Ajustados por Qualidade de Vida , Estados Unidos
15.
Int J Ment Health Syst ; 18(1): 12, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38448987

RESUMO

BACKGROUND: COVID-19 has had a significant impact on people's mental health and mental health services. During the first year of the pandemic, existing demand was not fully met while new demand was generated, resulting in large numbers of people requiring support. To support mental health services to recover without being overwhelmed, it was important to know where services will experience increased pressure, and what strategies could be implemented to mitigate this. METHODS: We implemented a computer simulation model of patient flow through an integrated mental health service in Southwest England covering General Practice (GP), community-based 'talking therapies' (IAPT), acute hospital care, and specialist care settings. The model was calibrated on data from 1 April 2019 to 1 April 2021. Model parameters included patient demand, service-level length of stay, and probabilities of transitioning to other care settings. We used the model to compare 'do nothing' (baseline) scenarios to 'what if' (mitigation) scenarios, including increasing capacity and reducing length of stay, for two future demand trajectories from 1 April 2021 onwards. RESULTS: The results from the simulation model suggest that, without mitigation, the impact of COVID-19 will be an increase in pressure on GP and specialist community based services by 50% and 50-100% respectively. Simulating the impact of possible mitigation strategies, results show that increasing capacity in lower-acuity services, such as GP, causes a shift in demand to other parts of the mental health system while decreasing length of stay in higher acuity services is insufficient to mitigate the impact of increased demand. CONCLUSION: In capturing the interrelation of patient flow related dynamics between various mental health care settings, we demonstrate the value of computer simulation for assessing the impact of interventions on system flow.

16.
iScience ; 27(3): 109235, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38439967

RESUMO

All proteins are translated in the cytoplasm, yet many, including transcription factors, play vital roles in the nucleus. While previous research has concentrated on molecular motors for the transport of these proteins to the nucleus, recent observations reveal perinuclear accumulation even in the absence of an energy source, hinting at alternative mechanisms. Here, we propose that structural properties of the cellular environment, specifically the endoplasmic reticulum (ER), can promote molecular transport to the perinucleus without requiring additional energy expenditure. Specifically, physical interaction between proteins and the ER impedes their diffusion and leads to their accumulation near the nucleus. This result explains why larger proteins, more frequently interacting with the ER membrane, tend to accumulate at the perinucleus. Interestingly, such diffusion in a heterogeneous environment follows Chapman's law rather than the popular Fick's law. Our findings suggest a novel protein transport mechanism arising solely from characteristics of the intracellular environment.

17.
Clin Ophthalmol ; 18: 699-712, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468913

RESUMO

Background: We studied the kinetic phenomenon of an airbag impact on eyes with different axial lengths using finite element analysis (FEA) to sequentially determine the physical and mechanical responses of intraocular segments at various airbag deployment velocities. Methods: The human eye model we created was used in simulations with the FEA program PAM-GENERISTM. The airbag was set to impact eyes with axial lengths of 21.85 mm (hyperopia), 23.85 mm (emmetropia) and 25.85 mm (myopia), at initial velocities of 20, 30, 40, 50 and 60 m/s. The deformation rate was calculated as the ratio of the length of three segments, anterior chamber, lens and vitreous, to that at the baseline from 0.2 ms to 2.0 ms after the airbag impact. Results: Deformation rate of the anterior chamber was greater than that of other segments, especially in the early phase, 0.2-0.4 ms after the impact (P < 0.001), and it reached its peak, 80%, at 0.8 ms. A higher deformation rate in the anterior chamber was found in hyperopia compared with other axial length eyes in the first half period, 0.2-0.8 ms, followed by the rate in emmetropia (P < 0.001). The lens deformation rate was low, its peak ranging from 40% to 75%, and exceeded that of the anterior chamber at 1.4 ms and 1.6 ms after the impact (P < 0.01). The vitreous deformation rate was lower throughout the simulation period than that of the other segments and ranged from a negative value (elongation) in the later phase. Conclusion: Airbag impact on the eyeball causes evident deformation, especially in the anterior chamber. The results obtained in this study, such as the time lag of the peak deformation between the anterior chamber and lens, suggest a clue to the pathophysiological mechanism of airbag ocular injury.

18.
Exp Ther Med ; 27(5): 180, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38515645

RESUMO

The number of artificial total hip revision arthroplasties is increasing yearly in China, and >50% of these cases have acetabular defects. Accurately locating and quantifying the bone defect is one of the current challenges of this surgery. Thus, the objective of the present study was to simulate acetabular implantation with the aid of Mimics 17.0 software (Materialise NV) in patients with loosened acetabular prosthesis, to evaluate the 'ideal acetabular center' and the 'actual acetabular center' to guide the choice of prosthesis and surgical method. From January 2017 to June 2021, the present study included 10 hips from 10 patients [seven men (seven hips) and three women (three hips)]. In all patients, the Mimics software was applied to simulate the dislocation of the femoral prosthesis and acetabular prosthesis implantation before surgery; calculate the height difference between the 'ideal acetabular center' and the 'actual acetabular center' to assess the bone defect; confirm the size of the acetabular prosthesis, abduction angle, anteversion angle and bone coverage of the acetabular cup; and measure the intraoperative bleeding and postoperative follow-up Harris score of the hip joint. After statistical analysis, the present study revealed that digital simulation assistance could improve the accuracy of hip revision acetabular prosthesis implantation, reduce postoperative shortening of the affected limb, especially for surgeons with relatively little experience in hip revision surgery, and greatly reduce the occurrence of complications such as hip dislocation because of poor postoperative prosthesis position.

19.
J Neural Eng ; 21(2)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38502956

RESUMO

Objective.Minimally invasive neuromodulation therapies like the Injectrode, which is composed of a tightly wound polymer-coated Platinum/Iridium microcoil, offer a low-risk approach for administering electrical stimulation to the dorsal root ganglion (DRG). This flexible electrode is aimed to conform to the DRG. The stimulation occurs through a transcutaneous electrical stimulation (TES) patch, which subsequently transmits the stimulation to the Injectrode via a subcutaneous metal collector. However, it is important to note that the effectiveness of stimulation through TES relies on the specific geometrical configurations of the Injectrode-collector-patch system. Hence, there is a need to investigate which design parameters influence the activation of targeted neural structures.Approach.We employed a hybrid computational modeling approach to analyze the impact of Injectrode system design parameters on charge delivery and neural response to stimulation. We constructed multiple finite element method models of DRG stimulation, followed by the implementation of multi-compartment models of DRG neurons. By calculating potential distribution during monopolar stimulation, we simulated neural responses using various parameters based on prior acute experiments. Additionally, we developed a canonical monopolar stimulation and full-scale model of bipolar bilateral L5 DRG stimulation, allowing us to investigate how design parameters like Injectrode size and orientation influenced neural activation thresholds.Main results.Our findings were in accordance with acute experimental measurements and indicate that the minimally invasive Injectrode system predominantly engages large-diameter afferents (Aß-fibers). These activation thresholds were contingent upon the surface area of the Injectrode. As the charge density decreased due to increasing surface area, there was a corresponding expansion in the stimulation amplitude range before triggering any pain-related mechanoreceptor (Aδ-fibers) activity.Significance.The Injectrode demonstrates potential as a viable technology for minimally invasive stimulation of the DRG. Our findings indicate that utilizing a larger surface area Injectrode enhances the therapeutic margin, effectively distinguishing the desired Aßactivation from the undesired Aδ-fiber activation.


Assuntos
Gânglios Espinais , Neurônios , Humanos , Gânglios Espinais/fisiologia , Dor , Estimulação Elétrica , Simulação por Computador
20.
Saudi Dent J ; 36(3): 387-394, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38525182

RESUMO

Background: The term "navigation" describes a device that can pinpoint critical anatomical features, the most direct path to the target, and the optimal surgical orientation. This study aimed to conduct a comprehensive literature search on computer-assisted navigation for use in oral and maxillofacial surgery. Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, relevant studies were retrieved from five electronic databases: Medline, Web of Science, PubMed, Google Scholar, and Saudi Digital Library (SDL). The central question was, "Does the computer-assisted navigation system improve the outcome of surgical procedures in the oral and maxillofacial region?" The Cochrane Risk of Bias 2 was used to determine the various types of bias. Results: Post-traumatic midfacial reconstruction is one of the many fields that have benefited from the use of computer-assisted navigation because of its reliability. It can also be used to extricate difficult foreign entities from the operative zone. Locating critical anatomical components, communicating the surgical plan to the patient, and verifying surgical success can improve the function and appearance of patients with dentofacial abnormalities. In addition, it decreases the surgical error margin and duration. Conclusion: Computer-assisted navigation is promising in surgical practice. The accuracy of surgery can be significantly enhanced by first planning the process in a virtual environment and then performing it under close supervision in real time. In addition, the time required for preoperative planning and surgery can be reduced by creating and improving software programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...