Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 500
Filtrar
1.
Technol Health Care ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38759043

RESUMO

BACKGROUND: Transrectal ultrasound-guided prostate biopsy is the gold standard diagnostic test for prostate cancer, but it is an invasive examination of non-targeted puncture and has a high false-negative rate. OBJECTIVE: In this study, we aimed to develop a computer-assisted prostate cancer diagnosis method based on multiparametric MRI (mpMRI) images. METHODS: We retrospectively collected 106 patients who underwent radical prostatectomy after diagnosis with prostate biopsy. mpMRI images, including T2 weighted imaging (T2WI), diffusion weighted imaging (DWI), and dynamic-contrast enhanced (DCE), and were accordingly analyzed. We extracted the region of interest (ROI) about the tumor and benign area on the three sequential MRI axial images at the same level. The ROI data of 433 mpMRI images were obtained, of which 202 were benign and 231 were malignant. Of those, 50 benign and 50 malignant images were used for training, and the 333 images were used for verification. Five main feature groups, including histogram, GLCM, GLGCM, wavelet-based multi-fractional Brownian motion features and Minkowski function features, were extracted from the mpMRI images. The selected characteristic parameters were analyzed by MATLAB software, and three analysis methods with higher accuracy were selected. RESULTS: Through prostate cancer identification based on mpMRI images, we found that the system uses 58 texture features and 3 classification algorithms, including Support Vector Machine (SVM), K-nearest Neighbor (KNN), and Ensemble Learning (EL), performed well. In the T2WI-based classification results, the SVM achieved the optimal accuracy and AUC values of 64.3% and 0.67. In the DCE-based classification results, the SVM achieved the optimal accuracy and AUC values of 72.2% and 0.77. In the DWI-based classification results, the ensemble learning achieved optimal accuracy as well as AUC values of 75.1% and 0.82. In the classification results based on all data combinations, the SVM achieved the optimal accuracy and AUC values of 66.4% and 0.73. CONCLUSION: The proposed computer-aided diagnosis system provides a good assessment of the diagnosis of the prostate cancer, which may reduce the burden of radiologists and improve the early diagnosis of prostate cancer.

2.
Cureus ; 16(4): e58400, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38756258

RESUMO

Artificial intelligence (AI) has the ability to completely transform the healthcare industry by enhancing diagnosis, treatment, and resource allocation. To ensure patient safety and equitable access to healthcare, it also presents ethical and practical issues that need to be carefully addressed. Its integration into healthcare is a crucial topic. To realize its full potential, however, the ethical issues around data privacy, prejudice, and transparency, as well as the practical difficulties posed by workforce adaptability and statutory frameworks, must be addressed. While there is growing knowledge about the advantages of AI in healthcare, there is a significant lack of knowledge about the moral and practical issues that come with its application, particularly in the setting of emergency and critical care. The majority of current research tends to concentrate on the benefits of AI, but thorough studies that investigate the potential disadvantages and ethical issues are scarce. The purpose of our article is to identify and examine the ethical and practical difficulties that arise when implementing AI in emergency medicine and critical care, to provide solutions to these issues, and to give suggestions to healthcare professionals and policymakers. In order to responsibly and successfully integrate AI in these important healthcare domains, policymakers and healthcare professionals must collaborate to create strong regulatory frameworks, safeguard data privacy, remove prejudice, and give healthcare workers the necessary training.

3.
Clin Chest Med ; 45(2): 249-261, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38816086

RESUMO

Early detection with accurate classification of solid pulmonary nodules is critical in reducing lung cancer morbidity and mortality. Computed tomography (CT) remains the most widely used imaging examination for pulmonary nodule evaluation; however, other imaging modalities, such as PET/CT and MRI, are increasingly used for nodule characterization. Current advances in solid nodule imaging are largely due to developments in machine learning, including automated nodule segmentation and computer-aided detection. This review explores current multi-modality solid pulmonary nodule detection and characterization with discussion of radiomics and risk prediction models.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imageamento por Ressonância Magnética , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Detecção Precoce de Câncer/métodos
4.
J Imaging Inform Med ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627268

RESUMO

Architectural distortion (AD) is one of the most common findings on mammograms, and it may represent not only cancer but also a lesion such as a radial scar that may have an associated cancer. AD accounts for 18-45% missed cancer, and the positive predictive value of AD is approximately 74.5%. Early detection of AD leads to early diagnosis and treatment of the cancer and improves the overall prognosis. However, detection of AD is a challenging task. In this work, we propose a new approach for detecting architectural distortion in mammography images by combining preprocessing methods and a novel structure fusion attention model. The proposed structure-focused weighted orientation preprocessing method is composed of the original image, the architecture enhancement map, and the weighted orientation map, highlighting suspicious AD locations. The proposed structure fusion attention model captures the information from different channels and outperforms other models in terms of false positives and top sensitivity, which refers to the maximum sensitivity that a model can achieve under the acceptance of the highest number of false positives, reaching 0.92 top sensitivity with only 0.6590 false positive per image. The findings suggest that the combination of preprocessing methods and a novel network architecture can lead to more accurate and reliable AD detection. Overall, the proposed approach offers a novel perspective on detecting ADs, and we believe that our method can be applied to clinical settings in the future, assisting radiologists in the early detection of ADs from mammography, ultimately leading to early treatment of breast cancer patients.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38632166

RESUMO

PURPOSE: Intracranial aneurysm detection from 3D Time-Of-Flight Magnetic Resonance Angiography images is a problem of increasing clinical importance. Recently, a streak of methods have shown promising performance by using segmentation neural networks. However, these methods may be less relevant in a clinical settings where diagnostic decisions rely on detecting objects rather than their segmentation. METHODS: We introduce a 3D single-stage object detection method tailored for small object detection such as aneurysms. Our anchor-free method incorporates fast data annotation, adapted data sampling and generation to address class imbalance problem, and spherical representations for improved detection. RESULTS: A comprehensive evaluation was conducted, comparing our method with the state-of-the-art SCPM-Net, nnDetection and nnUNet baselines, using two datasets comprising 402 subjects. The evaluation used adapted object detection metrics. Our method exhibited comparable or superior performance, with an average precision of 78.96%, sensitivity of 86.78%, and 0.53 false positives per case. CONCLUSION: Our method significantly reduces the detection complexity compared to existing methods and highlights the advantages of object detection over segmentation-based approaches for aneurysm detection. It also holds potential for application to other small object detection problems.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38645463

RESUMO

Purpose: To rule out hemorrhage, non-contrast CT (NCCT) scans are used for early evaluation of patients with suspected stroke. Recently, artificial intelligence tools have been developed to assist with determining eligibility for reperfusion therapies by automating measurement of the Alberta Stroke Program Early CT Score (ASPECTS), a 10-point scale with > 7 or ≤ 7 being a threshold for change in functional outcome prediction and higher chance of symptomatic hemorrhage, and hypodense volume. The purpose of this work was to investigate the effects of CT reconstruction kernel and slice thickness on ASPECTS and hypodense volume. Methods: The NCCT series image data of 87 patients imaged with a CT stroke protocol at our institution were reconstructed with 3 kernels (H10s-smooth, H40s-medium, H70h-sharp) and 2 slice thicknesses (1.5mm and 5mm) to create a reference condition (H40s/5mm) and 5 non-reference conditions. Each reconstruction for each patient was analyzed with the Brainomix e-Stroke software (Brainomix, Oxford, England) which yields an ASPECTS value and measure of total hypodense volume (mL). Results: An ASPECTS value was returned for 74 of 87 cases in the reference condition (13 failures). ASPECTS in non-reference conditions changed from that measured in the reference condition for 59 cases, 7 of which changed above or below the clinical threshold of 7 for 3 non-reference conditions. ANOVA tests were performed to compare the differences in protocols, Dunnett's post-hoc tests were performed after ANOVA, and a significance level of p < 0.05 was defined. There was no significant effect of kernel (p = 0.91), a significant effect of slice thickness (p < 0.01) and no significant interaction between these factors (p = 0.91). Post-hoc tests indicated no significant difference between ASPECTS estimated in the reference and any non-reference conditions. There was a significant effect of kernel (p < 0.01) and slice thickness (p < 0.01) on hypodense volume, however there was no significant interaction between these factors (p = 0.79). Post-hoc tests indicated significantly different hypodense volume measurements for H10s/1.5mm (p = 0.03), H40s/1.5mm (p < 0.01), H70h/5mm (p < 0.01). No significant difference was found in hypodense volume measured in the H10s/5mm condition (p = 0.96). Conclusion: Automated ASPECTS and hypodense volume measurements can be significantly impacted by reconstruction kernel and slice thickness.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38625446

RESUMO

PURPOSE: The quality and bias of annotations by annotators (e.g., radiologists) affect the performance changes in computer-aided detection (CAD) software using machine learning. We hypothesized that the difference in the years of experience in image interpretation among radiologists contributes to annotation variability. In this study, we focused on how the performance of CAD software changes with retraining by incorporating cases annotated by radiologists with varying experience. METHODS: We used two types of CAD software for lung nodule detection in chest computed tomography images and cerebral aneurysm detection in magnetic resonance angiography images. Twelve radiologists with different years of experience independently annotated the lesions, and the performance changes were investigated by repeating the retraining of the CAD software twice, with the addition of cases annotated by each radiologist. Additionally, we investigated the effects of retraining using integrated annotations from multiple radiologists. RESULTS: The performance of the CAD software after retraining differed among annotating radiologists. In some cases, the performance was degraded compared to that of the initial software. Retraining using integrated annotations showed different performance trends depending on the target CAD software, notably in cerebral aneurysm detection, where the performance decreased compared to using annotations from a single radiologist. CONCLUSIONS: Although the performance of the CAD software after retraining varied among the annotating radiologists, no direct correlation with their experience was found. The performance trends differed according to the type of CAD software used when integrated annotations from multiple radiologists were used.

8.
World J Gastrointest Endosc ; 16(3): 126-135, 2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38577646

RESUMO

The number and variety of applications of artificial intelligence (AI) in gastrointestinal (GI) endoscopy is growing rapidly. New technologies based on machine learning (ML) and convolutional neural networks (CNNs) are at various stages of development and deployment to assist patients and endoscopists in preparing for endoscopic procedures, in detection, diagnosis and classification of pathology during endoscopy and in confirmation of key performance indicators. Platforms based on ML and CNNs require regulatory approval as medical devices. Interactions between humans and the technologies we use are complex and are influenced by design, behavioural and psychological elements. Due to the substantial differences between AI and prior technologies, important differences may be expected in how we interact with advice from AI technologies. Human-AI interaction (HAII) may be optimised by developing AI algorithms to minimise false positives and designing platform interfaces to maximise usability. Human factors influencing HAII may include automation bias, alarm fatigue, algorithm aversion, learning effect and deskilling. Each of these areas merits further study in the specific setting of AI applications in GI endoscopy and professional societies should engage to ensure that sufficient emphasis is placed on human-centred design in development of new AI technologies.

9.
Radiol Artif Intell ; 6(3): e230318, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38568095

RESUMO

Purpose To develop an artificial intelligence (AI) model for the diagnosis of breast cancer on digital breast tomosynthesis (DBT) images and to investigate whether it could improve diagnostic accuracy and reduce radiologist reading time. Materials and Methods A deep learning AI algorithm was developed and validated for DBT with retrospectively collected examinations (January 2010 to December 2021) from 14 institutions in the United States and South Korea. A multicenter reader study was performed to compare the performance of 15 radiologists (seven breast specialists, eight general radiologists) in interpreting DBT examinations in 258 women (mean age, 56 years ± 13.41 [SD]), including 65 cancer cases, with and without the use of AI. Area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and reading time were evaluated. Results The AUC for stand-alone AI performance was 0.93 (95% CI: 0.92, 0.94). With AI, radiologists' AUC improved from 0.90 (95% CI: 0.86, 0.93) to 0.92 (95% CI: 0.88, 0.96) (P = .003) in the reader study. AI showed higher specificity (89.64% [95% CI: 85.34%, 93.94%]) than radiologists (77.34% [95% CI: 75.82%, 78.87%]) (P < .001). When reading with AI, radiologists' sensitivity increased from 85.44% (95% CI: 83.22%, 87.65%) to 87.69% (95% CI: 85.63%, 89.75%) (P = .04), with no evidence of a difference in specificity. Reading time decreased from 54.41 seconds (95% CI: 52.56, 56.27) without AI to 48.52 seconds (95% CI: 46.79, 50.25) with AI (P < .001). Interreader agreement measured by Fleiss κ increased from 0.59 to 0.62. Conclusion The AI model showed better diagnostic accuracy than radiologists in breast cancer detection, as well as reduced reading times. The concurrent use of AI in DBT interpretation could improve both accuracy and efficiency. Keywords: Breast, Computer-Aided Diagnosis (CAD), Tomosynthesis, Artificial Intelligence, Digital Breast Tomosynthesis, Breast Cancer, Computer-Aided Detection, Screening Supplemental material is available for this article. © RSNA, 2024 See also the commentary by Bae in this issue.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Mamografia , Sensibilidade e Especificidade , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Mamografia/métodos , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , República da Coreia/epidemiologia , Aprendizado Profundo , Adulto , Fatores de Tempo , Algoritmos , Estados Unidos , Reprodutibilidade dos Testes
10.
Phys Med ; 121: 103344, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38593627

RESUMO

PURPOSE: To validate the performance of computer-aided detection (CAD) and volumetry software using an anthropomorphic phantom with a ground truth (GT) set of 3D-printed nodules. METHODS: The Kyoto Kaguku Lungman phantom, containing 3D-printed solid nodules including six diameters (4 to 9 mm) and three morphologies (smooth, lobulated, spiculated), was scanned at varying CTDIvol levels (6.04, 1.54 and 0.20 mGy). Combinations of reconstruction algorithms (iterative and deep learning image reconstruction) and kernels (soft and hard) were applied. Detection, volumetry and density results recorded by a commercially available AI-based algorithm (AVIEW LCS + ) were compared to the absolute GT, which was determined through µCT scanning at 50 µm resolution. The associations between image acquisition parameters or nodule characteristics and accuracy of nodule detection and characterization were analyzed with chi square tests and multiple linear regression. RESULTS: High levels of detection sensitivity and precision (minimal 83 % and 91 % respectively) were observed across all acquisitions. Neither reconstruction algorithm nor radiation dose showed significant associations with detection. Nodule diameter however showed a highly significant association with detection (p < 0.0001). Volumetric measurements for nodules > 6 mm were accurate within 10 % absolute range from volumeGT, regardless of dose and reconstruction. Nodule diameter and morphology are major determinants of volumetric accuracy (p < 0.001). Density assignment was not significantly influenced by any parameters. CONCLUSIONS: Our study confirms the software's accurate performance in nodule volumetry, detection and density characterization with robustness for variations in CT imaging protocols. This study suggests the incorporation of similar phantom setups in quality assurance of CAD tools.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Impressão Tridimensional , Software
11.
Cancer Imaging ; 24(1): 40, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509635

RESUMO

BACKGROUND: Low-dose computed tomography (LDCT) has been shown useful in early lung cancer detection. This study aimed to develop a novel deep learning model for detecting pulmonary nodules on chest LDCT images. METHODS: In this secondary analysis, three lung nodule datasets, including Lung Nodule Analysis 2016 (LUNA16), Lung Nodule Received Operation (LNOP), and Lung Nodule in Health Examination (LNHE), were used to train and test deep learning models. The 3D region proposal network (RPN) was modified via a series of pruning experiments for better predictive performance. The performance of each modified deep leaning model was evaluated based on sensitivity and competition performance metric (CPM). Furthermore, the performance of the modified 3D RPN trained on three datasets was evaluated by 10-fold cross validation. Temporal validation was conducted to assess the reliability of the modified 3D RPN for detecting lung nodules. RESULTS: The results of pruning experiments indicated that the modified 3D RPN composed of the Cross Stage Partial Network (CSPNet) approach to Residual Network (ResNet) Xt (CSP-ResNeXt) module, feature pyramid network (FPN), nearest anchor method, and post-processing masking, had the optimal predictive performance with a CPM of 92.2%. The modified 3D RPN trained on the LUNA16 dataset had the highest CPM (90.1%), followed by the LNOP dataset (CPM: 74.1%) and the LNHE dataset (CPM: 70.2%). When the modified 3D RPN trained and tested on the same datasets, the sensitivities were 94.6%, 84.8%, and 79.7% for LUNA16, LNOP, and LNHE, respectively. The temporal validation analysis revealed that the modified 3D RPN tested on LNOP test set achieved a CPM of 71.6% and a sensitivity of 85.7%, and the modified 3D RPN tested on LNHE test set had a CPM of 71.7% and a sensitivity of 83.5%. CONCLUSION: A modified 3D RPN for detecting lung nodules on LDCT scans was designed and validated, which may serve as a computer-aided diagnosis system to facilitate lung nodule detection and lung cancer diagnosis.


A modified 3D RPN for detecting lung nodules on CT images that exhibited greater sensitivity and CPM than did several previously reported CAD detection models was established.


Assuntos
Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Humanos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Reprodutibilidade dos Testes , Imageamento Tridimensional/métodos , Pulmão , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
12.
Artigo em Inglês | MEDLINE | ID: mdl-38437999

RESUMO

BACKGROUND & AIMS: The use of computer-aided detection (CADe) has increased the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance in randomized controlled trials (RCTs) but has not shown benefit in real-world implementation studies. We performed a single-center pragmatic RCT to evaluate the impact of real-time CADe on ADRs in colonoscopy performed by community gastroenterologists. METHODS: We enrolled 1100 patients undergoing colonoscopy for CRC screening, surveillance, positive fecal-immunohistochemical tests, and diagnostic indications at one community-based center from September 2022 to March 2023. Patients were randomly assigned (1:1) to traditional colonoscopy or real-time CADe. Blinded pathologists analyzed histopathologic findings. The primary outcome was ADR (the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy (APC), sessile-serrated lesion detection rate, and non-neoplastic resection rate. RESULTS: The median age was 55.5 years (interquartile range, 50-62 years), 61% were female, 72.7% were of Hispanic ethnicity, and 9.1% had inadequate bowel preparation. The ADR for the CADe group was significantly higher than the traditional colonoscopy group (42.5% vs 34.4%; P = .005). The mean APC was significantly higher in the CADe group compared with the traditional colonoscopy group (0.89 ± 1.46 vs 0.60 ± 1.12; P < .001). The improvement in adenoma detection was driven by increased detection of <5 mm adenomas. CADe had a higher sessile-serrated lesion detection rate than traditional colonoscopy (4.7% vs 2.0%; P = .01). The improvement in ADR with CADe was significantly higher in the first half of the study (47.2% vs 33.7%; P = .002) compared with the second half (38.7% vs 34.9%; P = .33). CONCLUSIONS: In a single-center pragmatic RCT, real-time CADe modestly improved ADR and APC in average-detector community endoscopists. (ClinicalTrials.gov number, NCT05963724).

13.
Sci Rep ; 14(1): 6290, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491186

RESUMO

BC (Breast cancer) is the second most common reason for women to die from cancer. Recent workintroduced a model for BC classifications where input breast images were pre-processed using median filters for reducing noises. Weighed KMC (K-Means clustering) is used to segment the ROI (Region of Interest) after the input image has been cleaned of noise. Block-based CDF (Centre Distance Function) and CDTM (Diagonal Texture Matrix)-based texture and shape descriptors are utilized for feature extraction. The collected features are reduced in counts using KPCA (Kernel Principal Component Analysis). The appropriate feature selection is computed using ICSO (Improved Cuckoo Search Optimization). The MRNN ((Modified Recurrent Neural Network)) values are then improved through optimization before being utilized to divide British Columbia into benign and malignant types. However, ICSO has many disadvantages, such as slow search speed and low convergence accuracy and training an MRNN is a completely tough task. To avoid those problems in this work preprocessing is done by bilateral filtering to remove the noise from the input image. Bilateral filter using linear Gaussian for smoothing. Contrast stretching is applied to improve the image quality. ROI segmentation is calculated based on MFCM (modified fuzzy C means) clustering. CDTM-based, CDF-based color histogram and shape description methods are applied for feature extraction. It summarizes two important pieces of information about an object such as the colors present in the image, and the relative proportion of each color in the given image. After the features are extracted, KPCA is used to reduce the size. Feature selection was performed using MCSO (Mutational Chicken Flock Optimization). Finally, BC detection and classification were performed using FCNN (Fuzzy Convolutional Neural Network) and its parameters were optimized using MCSO. The proposed model is evaluated for accuracy, recall, f-measure and accuracy. This work's experimental results achieve high values of accuracy when compared to other existing models.


Assuntos
Algoritmos , Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Colúmbia Britânica
14.
Cancer Biomark ; 40(1): 1-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38517775

RESUMO

BACKGROUND: Breast cancer is one of the leading causes of death in women worldwide. Histopathology analysis of breast tissue is an essential tool for diagnosing and staging breast cancer. In recent years, there has been a significant increase in research exploring the use of deep-learning approaches for breast cancer detection from histopathology images. OBJECTIVE: To provide an overview of the current state-of-the-art technologies in automated breast cancer detection in histopathology images using deep learning techniques. METHODS: This review focuses on the use of deep learning algorithms for the detection and classification of breast cancer from histopathology images. We provide an overview of publicly available histopathology image datasets for breast cancer detection. We also highlight the strengths and weaknesses of these architectures and their performance on different histopathology image datasets. Finally, we discuss the challenges associated with using deep learning techniques for breast cancer detection, including the need for large and diverse datasets and the interpretability of deep learning models. RESULTS: Deep learning techniques have shown great promise in accurately detecting and classifying breast cancer from histopathology images. Although the accuracy levels vary depending on the specific data set, image pre-processing techniques, and deep learning architecture used, these results highlight the potential of deep learning algorithms in improving the accuracy and efficiency of breast cancer detection from histopathology images. CONCLUSION: This review has presented a thorough account of the current state-of-the-art techniques for detecting breast cancer using histopathology images. The integration of machine learning and deep learning algorithms has demonstrated promising results in accurately identifying breast cancer from histopathology images. The insights gathered from this review can act as a valuable reference for researchers in this field who are developing diagnostic strategies using histopathology images. Overall, the objective of this review is to spark interest among scholars in this complex field and acquaint them with cutting-edge technologies in breast cancer detection using histopathology images.


Assuntos
Neoplasias da Mama , Aprendizado Profundo , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Feminino , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos
15.
Comput Biol Med ; 172: 108240, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38460312

RESUMO

OBJECTIVE: Neoadjuvant chemotherapy (NACT) is one kind of treatment for advanced stage ovarian cancer patients. However, due to the nature of tumor heterogeneity, the clinical outcomes to NACT vary significantly among different subgroups. Partial responses to NACT may lead to suboptimal debulking surgery, which will result in adverse prognosis. To address this clinical challenge, the purpose of this study is to develop a novel image marker to achieve high accuracy prognosis prediction of NACT at an early stage. METHODS: For this purpose, we first computed a total of 1373 radiomics features to quantify the tumor characteristics, which can be grouped into three categories: geometric, intensity, and texture features. Second, all these features were optimized by principal component analysis algorithm to generate a compact and informative feature cluster. This cluster was used as input for developing and optimizing support vector machine (SVM) based classifiers, which indicated the likelihood of receiving suboptimal cytoreduction after the NACT treatment. Two different kernels for SVM algorithm were explored and compared. A total of 42 ovarian cancer cases were retrospectively collected to validate the scheme. A nested leave-one-out cross-validation framework was adopted for model performance assessment. RESULTS: The results demonstrated that the model with a Gaussian radial basis function kernel SVM yielded an AUC (area under the ROC [receiver characteristic operation] curve) of 0.806 ± 0.078. Meanwhile, this model achieved overall accuracy (ACC) of 83.3%, positive predictive value (PPV) of 81.8%, and negative predictive value (NPV) of 83.9%. CONCLUSION: This study provides meaningful information for the development of radiomics based image markers in NACT treatment outcome prediction.


Assuntos
Terapia Neoadjuvante , Neoplasias Ovarianas , Humanos , Feminino , Estudos Retrospectivos , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/cirurgia , Carcinoma Epitelial do Ovário/tratamento farmacológico , Carcinoma Epitelial do Ovário/cirurgia , Valor Preditivo dos Testes
16.
J Neurooncol ; 167(1): 219-227, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340295

RESUMO

PURPOSE: During stereotactic radiosurgery (SRS) planning for brain metastases (BM), brain MRIs are reviewed to select appropriate targets based on radiographic characteristics. Some BM are difficult to detect and/or definitively identify and may go untreated initially, only to become apparent on future imaging. We hypothesized that in patients receiving multiple courses of SRS, reviewing the initial planning MRI would reveal early evidence of lesions that developed into metastases requiring SRS. METHODS: Patients undergoing two or more courses of SRS to BM within 6 months between 2016 and 2018 were included in this single-institution, retrospective study. Brain MRIs from the initial course were reviewed for lesions at the same location as subsequently treated metastases; if present, this lesion was classified as a "retrospectively identified metastasis" or RIM. RIMs were subcategorized as meeting or not meeting diagnostic imaging criteria for BM (+ DC or -DC, respectively). RESULTS: Among 683 patients undergoing 923 SRS courses, 98 patients met inclusion criteria. There were 115 repeat courses of SRS, with 345 treated metastases in the subsequent course, 128 of which were associated with RIMs found in a prior MRI. 58% of RIMs were + DC. 17 (15%) of subsequent courses consisted solely of metastases associated with + DC RIMs. CONCLUSION: Radiographic evidence of brain metastases requiring future treatment was occasionally present on brain MRIs from prior SRS treatments. Most RIMs were + DC, and some subsequent SRS courses treated only + DC RIMs. These findings suggest enhanced BM detection might enable earlier treatment and reduce the need for additional SRS.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Radiocirurgia/métodos , Estudos Retrospectivos , Incidência , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patologia , Imageamento por Ressonância Magnética
17.
Breast Cancer Res ; 26(1): 21, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38303004

RESUMO

BACKGROUND: The wide heterogeneity in the appearance of breast lesions and normal breast structures can confuse computerized detection algorithms. Our purpose was therefore to develop a Lesion Highlighter (LH) that can improve the performance of computer-aided detection algorithms for detecting breast cancer on screening mammograms. METHODS: We hypothesized that a Cycle-GAN based Lesion Remover (LR) could act as an LH, which can improve the performance of lesion detection algorithms. We used 10,310 screening mammograms from 4,832 women that included 4,942 recalled lesions (BI-RADS 0) and 5,368 normal results (BI-RADS 1). We divided the dataset into Train:Validate:Test folds with the ratios of 0.64:0.16:0.2. We segmented image patches (400 × 400 pixels) from either lesions marked by MQSA radiologists or normal tissue in mammograms. We trained a Cycle-GAN to develop two GANs, where each GAN transferred the style of one image to another. We refer to the GAN transferring the style of a lesion to normal breast tissue as the LR. We then highlighted the lesion by color-fusing the mammogram after applying the LR to its original. Using ResNet18, DenseNet201, EfficientNetV2, and Vision Transformer as backbone architectures, we trained three deep networks for each architecture, one trained on lesion highlighted mammograms (Highlighted), another trained on the original mammograms (Baseline), and Highlighted and Baseline combined (Combined). We conducted ROC analysis for the three versions of each deep network on the test set. RESULTS: The Combined version of all networks achieved AUCs ranging from 0.963 to 0.974 for identifying the image with a recalled lesion from a normal breast tissue image, which was statistically improved (p-value < 0.001) over their Baseline versions with AUCs that ranged from 0.914 to 0.967. CONCLUSIONS: Our results showed that a Cycle-GAN based LR is effective for enhancing lesion conspicuity and this can improve the performance of a detection algorithm.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia/métodos , Mama/diagnóstico por imagem , Mama/patologia , Algoritmos , Curva ROC
18.
Open Forum Infect Dis ; 11(2): ofae020, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38328498

RESUMO

Background: Computer-aided detection (CAD) may be a useful screening tool for tuberculosis (TB). However, there are limited data about its utility in active case finding (ACF) in a community-based setting, and particularly in an HIV-endemic setting where performance may be compromised. Methods: We performed a systematic review and evaluated articles published between January 2012 and February 2023 that included CAD as a screening tool to detect pulmonary TB against a microbiological reference standard (sputum culture and/or nucleic acid amplification test [NAAT]). We collected and summarized data on study characteristics and diagnostic accuracy measures. Two reviewers independently extracted data and assessed methodological quality against Quality Assessment of Diagnostic Accuracy Studies-2 criteria. Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines were followed. Results: Of 1748 articles reviewed, 5 met with the eligibility criteria and were included in this review. A meta-analysis revealed pooled sensitivity of 0.87 (95% CI, 0.78-0.96) and specificity of 0.74 (95% CI, 0.55-0.93), just below the World Health Organization (WHO)-recommended target product profile (TPP) for a screening test (sensitivity ≥0.90 and specificity ≥0.70). We found a high risk of bias and applicability concerns across all studies. Subgroup analyses, including the impact of HIV and previous TB, were not possible due to the nature of the reporting within the included studies. Conclusions: This review provides evidence, specifically in the context of ACF, for CAD as a potentially useful and cost-effective screening tool for TB in a resource-poor HIV-endemic African setting. However, given methodological concerns, caution is required with regards to applicability and generalizability.

19.
Quant Imaging Med Surg ; 14(2): 1493-1506, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415154

RESUMO

Background: Detecting new pulmonary metastases by comparing serial computed tomography (CT) scans is crucial, but a repetitive and time-consuming task that burdens the radiologists' workload. This study aimed to evaluate the usefulness of a nodule-matching algorithm with deep learning-based computer-aided detection (DL-CAD) in diagnosing new pulmonary metastases on cancer surveillance CT scans. Methods: Among patients who underwent pulmonary metastasectomy between 2014 and 2018, 65 new pulmonary metastases missed by interpreting radiologists on cancer surveillance CT (Time 2) were identified after a retrospective comparison with the previous CT (Time 1). First, DL-CAD detected nodules in Time 1 and Time 2 CT images. All nodules detected at Time 2 were initially considered metastasis candidates. Second, the nodule-matching algorithm was used to assess the correlation between the nodules from the two CT scans and to classify the nodules at Time 2 as "new" or "pre-existing". Pre-existing nodules were excluded from metastasis candidates. We evaluated the performance of DL-CAD with the nodule-matching algorithm, based on its sensitivity, false-metastasis candidates per scan, and positive predictive value (PPV). Results: A total of 475 lesions were detected by DL-CAD at Time 2. Following a radiologist review, the lesions were categorized as metastases (n=54), benign nodules (n=392), and non-nodules (n=29). Upon comparison of nodules at Time 1 and 2 using the nodule-matching algorithm, all metastases were classified as new nodules without any matching errors. Out of 421 benign lesions, 202 (48.0%) were identified as pre-existing and subsequently excluded from the pool of metastasis candidates through the nodule-matching algorithm. As a result, false-metastasis candidates per CT scan decreased by 47.9% (from 7.1 to 3.7, P<0.001) and the PPV increased from 11.4% to 19.8% (P<0.001), while maintaining sensitivity. Conclusions: The nodule-matching algorithm improves the diagnostic performance of DL-CAD for new pulmonary metastases, by lowering the number of false-metastasis candidates without compromising sensitivity.

20.
J Gastroenterol Hepatol ; 39(5): 927-934, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38273460

RESUMO

BACKGROUND AND AIM: Computer-aided detection (CADe) systems can efficiently detect polyps during colonoscopy. However, false-positive (FP) activation is a major limitation of CADe. We aimed to compare the rate and causes of FP using CADe before and after an update designed to reduce FP. METHODS: We analyzed CADe-assisted colonoscopy videos recorded between July 2022 and October 2022. The number and causes of FPs and excessive time spent by the endoscopist on FP (ET) were compared pre- and post-update using 1:1 propensity score matching. RESULTS: During the study period, 191 colonoscopy videos (94 and 97 in the pre- and post-update groups, respectively) were recorded. Propensity score matching resulted in 146 videos (73 in each group). The mean number of FPs and median ET per colonoscopy were significantly lower in the post-update group than those in the pre-update group (4.2 ± 3.7 vs 18.1 ± 11.1; P < 0.001 and 0 vs 16 s; P < 0.001, respectively). Mucosal tags, bubbles, and folds had the strongest association with decreased FP post-update (pre-update vs post-update: 4.3 ± 3.6 vs 0.4 ± 0.8, 0.32 ± 0.70 vs 0.04 ± 0.20, and 8.6 ± 6.7 vs 1.6 ± 1.7, respectively). There was no significant decrease in the true positive rate (post-update vs pre-update: 95.0% vs 99.2%; P = 0.09) or the adenoma detection rate (post-update vs pre-update: 52.1% vs 49.3%; P = 0.87). CONCLUSIONS: The updated CADe can reduce FP without impairing polyp detection. A reduction in FP may help relieve the burden on endoscopists.


Assuntos
Pólipos do Colo , Colonoscopia , Diagnóstico por Computador , Humanos , Colonoscopia/métodos , Diagnóstico por Computador/métodos , Reações Falso-Positivas , Masculino , Feminino , Pessoa de Meia-Idade , Pólipos do Colo/diagnóstico , Pólipos do Colo/diagnóstico por imagem , Idoso , Gravação em Vídeo , Pontuação de Propensão , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...