Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.473
Filtrar
1.
J Dent ; : 105089, 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38772449

RESUMO

OBJECTIVE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy (trueness and precision), marginal and internal adaptation, and margin quality of zirconia crowns made by additive manufacturing compared to subtractive manufacturing technology. METHODS: The investigation adhered to the PRISMA-ScR guidelines for systematic reviews and was registered at the Prospero database (n°CRD42023452927). Four electronic databases, including PubMed, Scopus, Embase, and Web of Science and manual search was conducted to find relevant studies published until September 2023. In vitro studies that assessed the trueness and precision, marginal and internal adaptation, and margin quality of printed crowns compared to milled ones were included. Studies on crowns over implants, pontics, temporary restorations, laminates, or exclusively experimental materials were excluded. RESULTS: A total of 9 studies were included in the descriptive reporting and 7 for meta-analysis. The global meta-analysis of the trueness (P<0.74,I2=90%) and the margin quality (P<0.61,I2=0%) indicated no significant difference between the root mean square of printed and milled zirconia crowns. The subgroup analysis for the printing system showed a significant effect (P<0.01). The meta-analysis of the crown areas indicated no significant difference in most of the areas, except for the marginal (favoring milled crowns) and axial (favoring printed crowns) areas. For precision and adaptation, both methods showed a clinically acceptable level. CONCLUSIONS: Additive manufacturing technology produces crowns with trueness and margin quality comparable to subtractive manufacturing. Both techniques have demonstrated the ability to produce crowns with precision levels, internal discrepancy, and marginal fit within clinically acceptable limits. CLINICAL SIGNIFICANCE: s3D printing emerges as a promising and potentially applicable alternative method for manufacturing zirconia crowns, as it shows trueness and margin quality comparable to restorations produced by the subtractive method.

2.
Dent Mater ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38755042

RESUMO

OBJECTIVES: Resin composites may release bisphenol A (BPA) due to impurities present in the monomers. However, there is a lack of knowledge regarding the leaching characteristics of BPA from resin composites. Therefore, experimental resin composites were prepared with known amounts of BPA. The objective of this study was (1) to determine which amount of BPA initially present in the material leaches out in the short term and, (2) how this release is influenced by the resin composition. METHODS: BPA (0, 0.001, 0.01, or 0.1 wt%) was added to experimental resin composites containing 60 mol% BisGMA, BisEMA(3), or UDMA, respectively, as base monomer and 40 mol% TEGDMA as diluent monomer. Polymerized samples (n = 5) were immersed at 37 °C for 7 days in 1 mL of water, which was collected and refreshed daily. BPA release was quantified with UPLC-MS/MS after derivatization with pyridine-3-sulfonyl chloride. RESULTS: Between 0.47 to 0.67 mol% of the originally added BPA eluted from the resin composites after 7 days. Similar elution trends were observed irrespective of the base monomer. Two-way ANOVA showed a significant effect of the base monomer on BPA release, but the differences were small and not consistent. SIGNIFICANCE: The released amount of BPA was directly proportional to the quantity of BPA present in the resin composite as an impurity. BPA release was mainly diffusion-based, while polymer composition seemed to play a minor role. Our results underscore the importance for manufacturers only to use monomers of the highest purity in dental resin composites to avoid unnecessary BPA exposure in patients.

3.
Materials (Basel) ; 17(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38730767

RESUMO

Zirconia-reinforced lithium silicate (ZLS) is utilized as a material for prosthetic tooth crowns, offering enhanced strength compared to other dental glass-ceramics. In this study, we investigate a commercial ZLS material, provided in a fully crystallized form. We examine the effects of an optional post-processing heat treatment on micro-contact damage using controlled indentation tests simulating the primary modes of contact during chewing: axial and sliding. Our findings indicate that the heat treatment does not affect mechanical properties such as the elastic modulus, hardness and indentation fracture toughness. However, it does enhance the resistance to contact damage by fracture and chipping in both axial and sliding modes, as well as the resistance to crack initiation measured from sliding tests. This improvement is attributed to the refinement of the flaw population achieved through the heat treatment. The results are analysed using principles of contact and fracture mechanics theory, discussing their significance in prosthetic dentistry.

4.
Materials (Basel) ; 17(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38730904

RESUMO

Scanning force microscopy (SFM) is one of the most widely used techniques in biomaterials research. In addition to imaging the materials of interest, SFM enables the mapping of mechanical properties and biological responses with sub-nanometer resolution and piconewton sensitivity. This review aims to give an overview of using the scanning force microscope (SFM) for investigations on dental materials. In particular, SFM-derived methods such as force-distance curves (scanning force spectroscopy), lateral force spectroscopy, and applications of the FluidFM® will be presented. In addition to the properties of dental materials, this paper reports the development of the pellicle by the interaction of biopolymers such as proteins and polysaccharides, as well as the interaction of bacteria with dental materials.

5.
Materials (Basel) ; 17(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38730936

RESUMO

The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass-ionomer (B), self-adhesive resin (C), or resin-modified glass-ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.

6.
Luminescence ; 39(5): e4767, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38711417

RESUMO

Zinc polycarboxylate cement is one of the few dental materials that demonstrate true adhesion to tooth structure. It is suitable for use in living organisms without causing harm. Its strong adhesion to teeth and low level of irritancy are two important parameters for the dental applications. In this study, the dosimetry properties of zinc polycarboxylate cement using thermoluminescence (TL) method were investigated and determined the effectiveness of its use as a good dosimeter. According to the results of this study, the sample shows a good TL properties with three main peaks found around 140°C, 220°C and 330°C. It has a wide linear dose response between 72 Gy and 2.3 kGy and good reusability of the TL peak found at 330°C. Unfortunately, the TL peak intensity values are rapidly faded within a short waiting time interval. Zinc polycarboxylate cement, which is frequently used in dental crowns, can be used as a retrospective dosimeter for measuring the amount of radiation in space studies and nuclear accidents due to its wide linear dose-response curve in the high dose region.


Assuntos
Cimento de Policarboxilato , Dosimetria Termoluminescente , Zinco , Zinco/química , Cimento de Policarboxilato/química , Cimentos Dentários/química , Estudos Retrospectivos
7.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38706266

RESUMO

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Assuntos
Cerâmica , Humanos , Cerâmica/química , Cimentos de Resina/química , Porcelana Dentária/química , Prótese Dentária Fixada por Implante , Prótese Adesiva , Zircônio/química
8.
J Prosthodont ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734933

RESUMO

PURPOSE: To evaluate the effect of different printing orientations and post-polymerization time with thermal cycling on the translucency of 3D-printed denture base resins. METHODS: Heat-polymerized (HP) acrylic resin specimens were fabricated and 3D-printed denture base materials (NextDent, ASIGA, FormLabs) were printed with different printing orientations (0, 45, 90 degrees) and subjected to different post-polymerization times (15-, 30-, 60-, and 90-min). All specimens were polished and immersed in distilled water for 1 day at 37°C. CIEDE2000 was used to measure the translucency parameters (TP00) before and after thermal cycling (5000 cycles) recording the color parameters (L*, a*, b*) against a black and white background using a spectrophotometer. k-factors ANOVA followed by post hoc Tukey's test (α = .05) was performed for statistical analysis. RESULTS: The k-factors ANOVA test showed a significant effect of resin material, post-polymerization time, and printing orientation on translucency (p < 0.001). In comparison to HP, all 3D-printed resins showed lower translucency with all post-polymerization times and printing orientation (p < 0.001) except FormLabs resin (p > 0.05). For all 3D-printed resins, the translucency increased, with increasing the post-polymerization time (p < 0.001) and 60- and 90-min showed the highest translucency. For printing orientation, 90 and 45 degrees significantly showed high translucency in comparison to 0 degrees (p < 0.001). FormLabs showed significantly higher translucency when compared with NextDent and ASIGA per respective printing orientation and post-polymerization time. The translucency significantly decreased after thermal cycling for all tested resins (p < 0.001). CONCLUSION: The findings of this study demonstrated that the translucency of 3D-printed resins is influenced by the printing orientation, post-polymerization time, and resin type. As a result, choosing a resin type, and printing orientation, with a longer post-polymerization time should be considered since it may improve the esthetic appearance of the 3D-printed resins.

9.
Eur J Oral Sci ; : e12993, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778467

RESUMO

This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate-based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate-based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high-performance liquid chromatography (HPLC) grade water following ISO 10993-12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material-dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32-6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.

10.
J Adhes Dent ; 26(1): 125-134, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38770704

RESUMO

PURPOSE: To investigate the effect of adhesive type and long-term aging on the shear bond strength (SBS) between silica-based ceramics and composite cement (CC). MATERIALS AND METHODS: Lithium-silicate (LS), feldspathic (FD) and polymer-infiltrated ceramic (PIC) blocks were sectioned (10 x 12 x 2 mm) and divided into 24 groups considering the factors: "ceramics" (LS, FD, and PIC), "adhesive" (Ctrl: without adhesive; 2SC: 2-step conventional; 3SC: 3-step conventional; 1SU: 1-step universal), and "aging" (non-aged or aged [A]). After the surface treatments, CC cylinders (n = 15, Ø = 2 mm; height = 2 mm) were made and half of the samples were subjected to thermocycling (10,000) and stored in water at 37°C for 18 months. The samples were submitted to SBS testing (100 kgf, 1 mm/min) and failure analysis. Extra samples were prepared for microscopic analysis of the adhesive interface. SBS (MPa) data was analyzed by 3-way ANOVA and Tukey's test (5%). Weibull analysis was performed on the SBS data. RESULTS: All factors and interactions were significant for SBS (p<0.05). Before aging, there was no significant difference between the tested groups and the respective control groups. After aging, the LS_1SU (22.18 ± 7.74) and LS_2SC (17.32 ± 5.86) groups exhibited significantly lower SBS than did the LS_Ctrl (30.30 ± 6.11). Only the LS_1SU group showed a significant decrease in SBS after aging vs without aging. The LS_1SU (12.20) group showed the highest Weibull modulus, which was significantly higher than LS_2SC_A (2.82) and LS_1SU_A (3.15) groups. CONCLUSION: No type of adhesive applied after silane benefitted the long-term adhesion of silica-based ceramics to CC in comparison to the groups without adhesive.


Assuntos
Cerâmica , Colagem Dentária , Teste de Materiais , Cimentos de Resina , Resistência ao Cisalhamento , Dióxido de Silício , Dióxido de Silício/química , Cerâmica/química , Fatores de Tempo , Cimentos de Resina/química , Desenho Assistido por Computador , Propriedades de Superfície , Análise do Estresse Dentário , Cimentação/métodos , Porcelana Dentária/química , Humanos , Resinas Compostas/química , Cimentos Dentários/química , Compostos de Potássio/química , Silicatos de Alumínio/química , Temperatura
11.
J Conserv Dent Endod ; 27(4): 360-365, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38779215

RESUMO

Aim: To determine the effects of time and temperature on the viscosity of preheated composite resins. Materials and Methods: Eleven composite resins were heated to 60°C, and temperature analyses were performed at intervals of 1 min until they had cooled to 25°C. The permanent oscillatory shear test was performed at 25°C, 35°C, 50°C, and 60°C for three composite resins under a shear rate of 1s-1. One- and two-way analysis of variance were used for the analysis (α = 0.05). Results: There was no significant interaction between the composite resin and time (P = 0.9304), and only the main effect time was significantly different (P < 0.0001). A difference was observed between T0 and T6 (P < 0.001), but not after T7. The increase in temperature resulted in a viscosity reduction (P < 0.05). At 25°C, Beautifil II presented higher viscosity. Palfique LX5 showed a significant viscosity reduction with increasing temperature compared with the others (P < 0.05). For Beautifil II and Z100, there was no difference at temperatures of 50°C and 60°C, while for Palfique LX5, no statistical difference was observed at 35°C, 50°C, and 60°C. Conclusions: Ten minutes of preheating were sufficient to reach a temperature of 60°C, reducing viscosity by at least 84%. However, 5 min after removal, the composite resin cooled to room temperature. Clinical Significance: Preheating composite resin has potential benefits. To determine how this approach will work in clinical practice, it is important to define the effects of time and temperature in the protocol of this technique and understand its limitations.

12.
J Adv Prosthodont ; 16(2): 77-90, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38694191

RESUMO

PURPOSE: The study aims to investigate the influence of the ferrule effect and types of posts on the stress distribution in three morphological types of the maxillary central incisor. MATERIALS AND METHODS: Nine models were created for 3 maxillary central incisor morphology types: "Fat" type - crown 12.5 mm, root 13 mm, and buccolingual cervical diameter 7.5 mm, "Medium" type - crown 11 mm, root 14 mm, and buccolingual cervical diameter 6.5 mm, and "Slim" type - crown 9.5 mm, root 15 mm, and buccolingual cervical diameter 5.5 mm. Each model received an anatomical castable post-and-core or glass-fiber post with resin composite core and three ferrule heights (nonexistent, 1 mm, and 2 mm). Then, a load of 14 N was applied at the cingulum with a 45° slope to the long axis of the tooth. The Maximum Principal Stress and the Minimum Principal Stress were calculated in the root dentin, crown, and core. RESULTS: Higher tensile and compression stress values were observed in root dentin using the metallic post compared to the fiber post, being higher in the slim type maxillary central incisor than in the medium and fat types. Concerning the three anatomical types of maxillary central incisors, the slim type without ferrule height in mm presented the highest tensile stress in the dentin, for both types of metal and fiber posts. CONCLUSION: Post system and tooth morphology were able to modify the biomechanical response of restored endodontically-treated incisors, showing the importance of personalized dental treatment for each case.

13.
Med Pharm Rep ; 97(2): 205-214, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38746037

RESUMO

Background and aims: Dental veneers have become increasingly required among patients, but little is known about the optical properties of veneers obtained from the same ceramic material through different processing techniques. Methods: In this study we compared the translucency and the opalescence parameters of zirconia-reinforced lithium silicate (ZLS) veneers restorations fabricated through CAD/CAM milling and hot-pressing techniques on the upper central incisor. Eighty specimens divided into 8 groups (n=10) were sectioned (Celtra Duo) and heat pressed (Celtra Press) to obtain 0.8 mm thickness. The optical parameters were calculated from the color difference against different backgrounds. Analysis of variance, one way ANOVA and post-hoc multiple comparison tests were used to evaluate and compare the optical properties of the same material, with a significance level of p < 0.05. Results: The processing method had significant effect on optical parameters. Celtra Duo HT proved to be the material with the highest transparency degree. The hot-pressing technique led to higher opacity than CAD/CAM milling technique. Conclusions: For a bio-mimetic aesthetic prosthetic restoration, the ceramic materials must have the same translucency and opacity as the real tooth. The results of this study revealed that high translucency ZLS obtained through hot pressing technique was the material of choice, as it fulfilled these requirements.

14.
Odontology ; 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38705962

RESUMO

The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.

15.
Curr Oral Health Rep ; 11(2): 87-94, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38706577

RESUMO

Purpose of Review: Dental caries or tooth decay is one of the communal problems in the world which can affect not only the oral health but also the general health conditions. The main objective of this systematic review is to explore the efficacy of bioactive glass-based toothpastes against cariogenic bacteria. Recent Findings: Bioactive glass particulates containing toothpaste show better remineralization potential on demineralized enamel and dentin when compared with toothpaste containing various bioactive constituents such as fluoride and potassium chloride. These constituents in conventional toothpaste can rapidly streak off due to acidic impact in the oral environment as the bioactive glass provides minerals for demineralized enamel and dentin by forming a strong hydroxyapatite (HAp) layer on its surface. Further, the therapeutic ions present in the bioglass can resist plaque formation by raising the pH of the surrounding environment or saliva and create amicable media for healthier teeth. Summary: Toothpaste containing bioactive glass particles undoubtedly displayed the remineralizing potentiality of the dental hard tissues. Dynamics of the mineralization through different bioactive glass materials needs further investigations. In order to prevent dental cavities and improve oral health, it is important to identify and study different effective bioglass particles in toothpaste.

16.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762747

RESUMO

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Assuntos
Materiais para Moldagem Odontológica , Glutaral , Teste de Materiais , Polivinil , Siloxanas , Materiais para Moldagem Odontológica/química , Polivinil/química , Siloxanas/química , Fatores de Tempo , Glutaral/química , Desinfetantes de Equipamento Odontológico/química , Hipoclorito de Sódio/química , Desinfetantes/química , Clorexidina/química , Propriedades de Superfície , Humanos
17.
Saudi Dent J ; 36(5): 765-769, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766280

RESUMO

Background: The objective of this study was to compare the cytotoxicity of TDV and Rebase II denture hard liners on human gingival fibroblasts, aiming to address issues associated with incomplete polymerization and free monomers that affect material properties. Methods: Seventy-two specimens (24 each of TDV, Rebase II, and controls) were prepared under aseptic conditions according to factory instructions. Cytotoxicity was determined using the MTT test with methyl tetrazolium salt added to the cell culture medium. A two-way ANOVA and a post-hoc Tukey test was used to evaluate the results of incubation before mitochondrial activity was measured using Multiscan spectrophotometry (570 nm). Results: There were significant differences in cell viability between the groups after 24 hours (P < 0.001), with TDV having higher viability than Rebase II. The difference between Rebase II and TDV, however, was not significant at 48 and 96 hours (P > 0.131). At 24 hours, Rebase II exhibited significantly lower viability than TDV liner, with a significant difference between the two groups (P = 0.001). Conclusion: Due to the maximum monomer release in the early hours of incubation, the amount of cytotoxicity decreased with increasing incubation time.

18.
Saudi Dent J ; 36(5): 778-788, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38766288

RESUMO

Aim: The aim of this study was to identify and analyze the most cited articles on vital pulp therapies. Methodology: Bibliographical data related to the abstract, citations, keywords, and other relevant information was extracted using different combinations of keywords. Further evaluation and visualization of the selected data were performed with the help of various tools, including MS Excel, Microsoft Word, Google open refine, BibExcel, and VOS viewer. An initial search revealed 91 documents, of which 40 were chosen for further analysis. We used the Kolmogorov-Smirnov test and Spearman correlation coefficient test, and our adopted significance level was p < 0.05. Results: In total, the articles received 1,905 citations, with six of them receiving at least 100 citations. Among the top 40 articles, the United States of America (10 articles) and Ireland (6 articles) were the countries with the highest number of cited articles. The journals "Journal of Endodontics" (14 articles; 650 citations) and "International Endodontic Journal" (13 articles; 577 citations) published most of the articles among the 50 most cited ones. Duncan H. was the author with the highest number of works cited (11 articles; 339 citations). Of the articles, systematic reviews accounted for 32%, literature reviews for 14%, in vitro experimental studies for 12%, clinical trials for 8%. Among the biomaterials used in vital pulp therapies, mineral trioxide aggregate (MTA) was discussed in 37 articles (74%), followed by calcium hydroxide, mentioned in 30 studies (60%). Interestingly, the publication year did not demonstrate a significant impact on citation count. Conclusion: The present study provided a detailed list of the top 50 most cited and classic articles on vital pulp therapies. This will help researchers, students, and clinicians in the field of endodontics with an impressive source of information.

19.
Dent Mater ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762399

RESUMO

OBJECTIVES: To evaluate, in a prospective clinical study over 5 years with ex vivo 3D profilometry analyses, the intraoral wear of Polymer-Infiltrated Ceramic Network (PICN) CAD-CAM composite restorations used in severe tooth wear treatment with the One-Step No-Prep technique. METHODS: 192 PICN (Vita Enamic) restorations on molars and premolars were included in a prospective clinical study involving patients treated according to the One-step No-prep protocol (n = 7). All patients showed clinical signs of bruxism. Replicas of restorations on molars and premolars were realized at each evaluation time (baseline and then every year up to 5 years) and scanned to perform 3D profilometry. Baseline and recall scans were superimposed with Geomagic Control software. The mean material wear was calculated for the full occlusal area (FOA) and for the occlusal contact area (OCA), respectively. Clinical evaluation of restorations was performed at recall. RESULTS: At 5 years, the estimated mean material wear for FOA was inferior to the accuracy threshold of the profilometry measurement chain. For OCA, the estimated mean wear of the material was - 27.97 µm. This material wear was shown to be significantly influenced by time (p < 0.0001) and patient (p = 0.026), while the type of tooth (molar or premolar) had no influence. At 5 years, the survival and the success rates of restorations were 99.48% and 90.62%, respectively. SIGNIFICANCE: The PICN material exhibits a low wear process in the treatment of severe tooth wear despite the presence of clinical signs of bruxism, and it constitutes a suitable material for the One-step No-prep technique.

20.
Int J Paediatr Dent ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38590044

RESUMO

BACKGROUND: The evidence underpinning caries management for children has progressed dramatically over the past 20 years. Anecdotally, this is not reflected in the teaching provided to undergraduate dental students, with the ongoing teaching of outdated methods within some dental schools. AIM: To capture the current undergraduate teaching provision and clinical treatment experience requirement relative to caries management in paediatric dentistry in UK dental schools. DESIGN: Cross-sectional analysis of current teaching methods on paediatric caries management was obtained using a piloted online data collection form. Question content included current caries teaching methods, assessment of student exposure and competence. The results were analysed descriptively. RESULTS: Of the 16 UK dental schools, 14 participated. Discrepancy in teaching content was apparent. Many schools (n = 9) taught biological caries management through therapeutic fissure sealants, yet this was not reflected in assessment and clinical requirements. Some schools (n = 4) taught amalgam placement in children, and most (n = 12) operatively taught treatments that would no longer be routinely provided in general dental practice in the UK, including primary tooth pulpotomy. CONCLUSION: There is substantial variation in the paediatric caries management techniques that are taught across UK dental schools, demonstrating a need for a national consensus to address these disparities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...