Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.528
Filtrar
1.
Quant Imaging Med Surg ; 14(9): 6362-6373, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39281141

RESUMO

Background: In many clinical situations, it is critical to exclude or identify abnormally lymph nodes (LNs). The nature of superficial abnormally LNs is closely related to the stage, treatment, and prognosis of the disease. Ultrasound (US) is an important method for examining superficial LNs due to its cheap and safe characteristics. However, it is still difficult to determine the nature of some LNs with overlapping benign and malignant features in images. Contrast-enhanced ultrasound (CEUS) can be used to evaluate the microperfusion status of tissues in real time, and it can improve diagnostic accuracy to a certain extent. Therefore, in this study, we will analyze the correlation between CEUS quantitative parameters and benign and malignant superficial abnormally LNs, to evaluate the efficacy and value of CEUS in distinguishing benign and malignant superficial LNs. Methods: This study retrospectively analyzed 120 patients of abnormal LNs who underwent US and CEUS at the China-Japan Union Hospital of Jilin University from December 2020 to August 2023. All 120 cases of abnormal LNs underwent US-guided coarse needle biopsy, and accurate pathological results were obtained, along with complete US and CEUS images. According to the pathological results, LNs were divided into benign and malignant groups, and the qualitative and quantitative parameters of US and CEUS between the two groups were analyzed. The cutoff value is determined by the receiver operating characteristic (ROC) curve of the subjects, and sensitivity, specificity, and accuracy are applied to evaluate the ability of the cutoff value to distinguish between the two groups. Results: There were a total of 120 LNs, including 36 in the benign group and 84 in the malignant group. The results showed that malignant LNs were usually characterized by the disappearance of lymphatic hilum, round ness index (L/T) <2, irregular morphology, and the manifestation of uneven perfusion (P<0.05). The differences in the quantitative parameters peak enhancement (PE), rise time (RT), time to peak (TTP), wash-in rate (WIR), and wash-out rate (WOR) were statistically significant (P<0.05). The result showed that RT and TTP in the malignant LNs were higher than those in the benign LNs, while the PE, WIR, and WOR were lower. A comparison of the ∆ values showed that the differences in ∆PE, ∆WIR, and ∆fall time (FT) were statistically significant (P<0.05), Among them, the ∆PE and ∆WIR of malignant LNs were higher than those of benign LNs, while the ∆FT was lower than that of benign LNs. Conclusions: Quantitative analysis of CEUS features is valuable in the diagnosis of benign and malignant LNs, and US combined with CEUS helps to improve the accuracy of identifying the nature of LNs.

2.
Quant Imaging Med Surg ; 14(9): 6556-6565, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39281156

RESUMO

Background: Endoleaks are common complications after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Computed tomographic angiography (CTA)/digital subtraction angiography (DSA) is considered the gold standard for evaluating contrast-enhanced ultrasound (CEUS) accuracy in the detection and classification of endoleaks. In recent years, CEUS has been widely used in this field. This study aimed to analyze the accuracy of CEUS in the detection and classification of endoleaks after EVAR. Methods: The data of 98 patients who underwent abdominal aorta CEUS from November 2017 to September 2023 in the ultrasound (US) department of Beijing Hospital were retrospectively analyzed. All the patients underwent EVAR of AAA before CEUS and CTA/DSA, and had complete clinical data. The CEUS and CTA/DSA results were compared to detect endoleaks and categorize the specific types of endoleaks. Results: Among the 98 patients, 74 were male and 24 were female. The patients had an average age of 74.8±9.8 years (range, 43-90 years). Among the 98 patients, 37 (37.8%) endoleaks were detected by CEUS, of which 8 were type Ia, 2 were type Ib, 15 were type II, 7 were type III, 2 were type IV, 2 were type Ia combined with type III, and 1 was type II combined with type III. In addition, among these 98 patients, 39 (39.8%) endoleaks were detected by CTA/DSA, of which 8 were type Ia, 3 were type Ib, 18 were type II, 6 were type III, 2 were type Ia combined with type III, 1 was type II combined with type III, and 1 was type Ib combined with type II. The sensitivity and specificity of CEUS in the detection of endoleaks were 92.3% and 98.3%, respectively. CEUS and CTA/DSA had similar diagnostic efficacy and good consistency in the detection and classification of endoleaks (Kappa value: 0.914, P<0.01). Conclusions: CEUS has high sensitivity and specificity in the detection and classification of endoleaks following EVAR, and its diagnostic efficacy is similar to that of CTA/DSA. In addition, US is safe, non-invasive and repeatable, and thus is worthy of extensive clinical application.

3.
Gland Surg ; 13(8): 1437-1447, 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39282044

RESUMO

Background: Thyroid cancer (TC) prone to cervical lymph node (CLN) metastasis both before and after surgery. Ultrasonography (US) is the first-line imaging method for evaluating the thyroid gland and CLNs. However, this assessment relies mainly on the subjective judgment of the sonographer and is very much dependent on the sonographer's experience. This prospective study was designed to construct a machine learning model based on contrast-enhanced ultrasound (CEUS) videos of CLNs to predict the risk of CLN metastasis in patients with TC. Methods: Patients who were proposed for surgical treatment due to TC from August 2019 to May 2020 were prospectively included. All patients underwent US of CLNs suspected of metastasis, and a 2-minute imaging video was recorded. After target tracking, feature extraction, and feature selection through the lymph node imaging video, three machine learning models, namely, support vector machine, linear discriminant analysis (LDA), and decision tree (DT), were constructed, and the sensitivity, specificity, and accuracy of each model for diagnosing lymph nodes were calculated by leave-one-out cross-validation (LOOCV). Results: A total of 75 lymph nodes were included in the study, with 42 benign cases and 33 malignant cases. Among the machine learning models constructed, the support vector machine had the best diagnostic efficacy, with a sensitivity of 93.0%, a specificity of 93.8%, and an accuracy of 93.3%. Conclusions: The machine learning model based on US video is helpful for the diagnosis of whether metastasis occurs in the CLNs of TC patients.

4.
J Clin Med ; 13(17)2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39274258

RESUMO

Background/Objectives: Untreated hepatic abscesses (HAs) have an 80% mortality rate and can be caused by bacteria and fungi. Previously managed with surgery, current treatments now utilize interventional radiology and antibiotics, reducing complications to 2.5%. This study evaluates contrast-enhanced ultrasound (CEUS) for better drainage placement and monitoring, overcoming conventional ultrasound's limitations in detecting the HA liquefied portion. Methods: We conducted a retrospective study of 50 patients with HAs confirmed via computed tomography (CT) scans. Inclusion criteria comprised specific clinical symptoms and laboratory parameters. Both B-mode and CEUS were utilized for initial and follow-up imaging. Results: In the CEUS studies, the mean size of HAs was 6.26 cm, with pus displaying significantly lower echogenicity compared to the HA pouch and liver parenchyma in all phases. Classification by size (>6 cm, <6 cm) and volume (>113 mL, <113 mL) revealed differences in the assessment of fluid volume between CEUS and B-mode. Conclusions: CEUS is valuable for diagnosing, performing therapeutic procedures, and monitoring HA. It provides precise real-time assessment of HA morphology, including dimensions and volume. If the liquefied volume of an HA exceeds 113 mL, it may qualify for drainage placement. CEUS can replace CT as an effective, less harmful, and cheaper method, eliminating the need for multiple radiological departments. While CEUS is a safer, cost-effective alternative to CT for HA evaluation and monitoring, comprehensive clinical evaluation remains essential. Therefore, CEUS should be part of a broader diagnostic and monitoring strategy, not a stand-alone solution.

5.
Ultrasound Med Biol ; 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39278802

RESUMO

OBJECTIVES: We explored the value of contrast-enhanced ultrasound (CEUS) in evaluating femoral head (FH) perfusion, guiding interventions and follow-up for infants with developmental dysplasia of the hip (DDH) and septic arthritis of the hip (SAH). The aim was to provide robust evidence for clinical assessment. METHODS: Ten infants, including 7 with DDH and 3 with SAH, were prospectively enrolled, with their bilateral hips alternately scanned during the CEUS exams. Twenty hips were classified into the case group (n = 11) and the control group (n = 9). Pre- and post-interventional studies were performed in DDH infants requiring interventions. FH perfusion was assessed by the perfusion area ratio (PAR) and quadrant location of microbubble-defect regions. RESULTS: In the case group, 25 CEUS studies were conducted, including 11 baseline, 7 follow-up and 7 post-intervention studies. The PAR significantly decreased in the case group (49.79% vs. 100.00%, p < 0.05). The microbubble-defect regions averagely affected 2 quadrants, primarily quadrat No. 3 (30%) and No. 4 (32%). Seven hip abduction angle adjustments were made based on pre-interventional studies, resulting in a significant increase in PAR in post-interventional studies (37.63% vs. 60.24%, p < 0.05). PAR increased in follow-up studies compared to baseline values (45.61% vs. 76.07%, p < 0.05). The inter- and intra-observer reproducibility of PAR measurements were excellent (intraclass correlation coefficient, both 0.97). CONCLUSION: CEUS proves to be a promising technique for quantitatively detecting FH perfusion in DDH and SAH infants with high reproducibility. It is valuable for baseline, intra-intervention and follow-up studies, aiming in clinical conditions and therapeutic effect evaluation.

6.
BMC Med Imaging ; 24(1): 242, 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39285357

RESUMO

OBJECTIVES: To establish a nomogram for differentiating malignant and benign focal liver lesions (FLLs) using ultrasomics features derived from contrast-enhanced ultrasound (CEUS). METHODS: 527 patients were retrospectively enrolled. On the training cohort, ultrasomics features were extracted from CEUS and b-mode ultrasound (BUS). Automatic feature selection and model development were performed using the Ultrasomics-Platform software, outputting the corresponding ultrasomics scores. A nomogram based on the ultrasomics scores from artery phase (AP), portal venous phase (PVP) and delayed phase (DP) of CEUS, and clinical factors were established. On the validation cohort, the diagnostic performance of the nomogram was assessed and compared with seniorexpert and resident radiologists. RESULTS: In the training cohort, the AP, PVP and DP scores exhibited better differential performance than BUS score, with area under the curve (AUC) of 84.1-85.1% compared with the BUS (74.6%, P < 0.05). In the validation cohort, the AUC of combined nomogram and expert was significantly higher than that of the resident (91.4% vs. 89.5% vs. 79.3%, P < 0.05). The combined nomogram had a comparable sensitivity with the expert and resident (95.2% vs. 98.4% vs. 97.6%), while the expert had a higher specificity than the nomogram and the resident (80.6% vs. 72.2% vs. 61.1%, P = 0.205). CONCLUSIONS: A CEUS ultrasomics based nomogram had an expert level performance in FLL characterization.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Nomogramas , Ultrassonografia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Ultrassonografia/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Retrospectivos , Diagnóstico Diferencial , Adulto , Idoso , Sensibilidade e Especificidade , Fígado/diagnóstico por imagem
7.
Ultrasound Med Biol ; 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39237425

RESUMO

OBJECTIVE: To assess the ability of the pressure gradient between breast lesions and adjacent normal tissue estimated by 3D subharmonic-aided pressure estimation (SHAPE) to characterize indeterminate breast lesions. METHODS: This prospective study enrolled patients scheduled for ultrasound-guided needle biopsies of a breast lesion. Before the biopsy, 3D SHAPE data were collected from the breast lesion during the infusion of an ultrasound contrast agent (Definity) as well as after clearance of the agent. Direct, invasive pressure measurements in the lesion and adjacent normal tissue were then obtained using an intracompartmental pressure monitoring system (C2DX) before tissue sampling as part of the biopsy procedure. The mean SHAPE gradient and invasive measurement gradient between the lesion and adjacent normal tissue were compared to the biopsy results. The SHAPE gradients were also compared to the invasive pressure gradients. RESULTS: There were 8 malignant and 13 benign lesions studied. The SHAPE gradients and invasive pressure gradients were significantly different between the benign and malignant lesions (2.86 ± 3.24 vs. -0.03 ± 1.72 a.u.; p = 0.03 and 9.9 ± 8.5 vs. 20.9 ± 8.0 mmHg; p = 0.008, respectively). The area under the curves, specificities, and sensitivities for detecting malignancy by SHAPE gradients and invasive pressure gradients were 0.79 and 0.88, 77% and 92%, and 88% and 50%, respectively. A weak negative correlation was found between the SHAPE and invasive pressure gradients (r = -0.2). CONCLUSION: The pressure gradient between a breast lesion and adjacent normal tissue estimated by 3D SHAPE shows potential for characterizing indeterminate breast lesions.

8.
Ultrasound ; 32(3): 140-149, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39100794

RESUMO

Background: The advent and increased use of high-resolution ultrasonography has resulted in improved detection of thyroid nodules. Even with the use of various Thyroid Imaging-Reporting and Data System, accurate imaging diagnosis of malignant thyroid nodules has been suboptimal, which necessitated use of newer modalities like contrast-enhanced ultrasonography alone and in combination for this purpose. Although the combined use of various Thyroid Imaging-Reporting and Data System and contrast-enhanced ultrasonography has turned out to be accurate in many studies, the ideal way to integrate contrast-enhanced ultrasonography into the Thyroid Imaging-Reporting and Data System algorithm is under-investigated. Purpose: To estimate and compare the diagnostic accuracy of American College of Radiology Thyroid Imaging-Reporting and Data System and contrast-enhanced ultrasonography in differentiating benign and malignant nodules alone and in combination. To estimate the diagnostic accuracy of contrast-enhanced ultrasonography in re-categorisation of Thyroid Imaging-Reporting and Data System 3 and Thyroid Imaging-Reporting and Data System 4 thyroid nodules. Materials and methods: This was a prospective cohort study performed in a tertiary care university-based hospital for 3 years. Adult patients with clinical or previous sonographic diagnosis of thyroid nodules were selected. Each of the nodules were assessed using ultrasonography and categorised using American College of Radiology Thyroid Imaging-Reporting and Data System criteria. The lesion was then assessed for contrast-enhanced ultrasonography features. The final diagnosis of the nodules was made using fine needle aspiration cytology. The diagnostic accuracy in diagnosis of malignant thyroid nodules for each of the American College of Radiology Thyroid Imaging-Reporting and Data System and contrast-enhanced ultrasonography alone and in combination was assessed. The diagnostic accuracy of contrast-enhanced ultrasonography in diagnosis of malignant thyroid nodules categorised as Thyroid Imaging-Reporting and Data System 3 and Thyroid Imaging-Reporting and Data System 4 was also assessed. Results: American College of Radiology Thyroid Imaging-Reporting and Data System had a sensitivity, specificity, negative predictive value, positive predictive value and diagnostic accuracy of 86.6%, 54.5%, 17.4%, 97.3% and 57.7%, respectively, in diagnosis of malignant thyroid nodules. Contrast-enhanced ultrasonography had a sensitivity, specificity, negative predictive value, positive predictive value and diagnostic accuracy of 86.6%, 95.4%, 67.9%, 98.4% and 94.4%, respectively, in diagnosis of malignant thyroid nodules. Contrast-enhanced ultrasonography had sensitivity, specificity, negative predictive value, positive predictive value and diagnostic accuracy of 93.3%, 100.0%, 100.0%, 99.2% and 99.3%, respectively, in re-categorisation of Thyroid Imaging-Reporting and Data System 3 and Thyroid Imaging-Reporting and Data System 4 nodules. Conclusion: Contrast-enhanced ultrasonography can play a key role in diagnosis of malignant thyroid nodules which are categorised as indeterminate on grey-scale ultrasound.

9.
Eur Radiol ; 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120792

RESUMO

OBJECTIVES: To evaluate grayscale US combined with contrast-enhanced ultrasound (CEUS) in the preoperative differentiation between benign and malignant ovarian masses in a pediatric population. MATERIALS AND METHODS: This retrospective study enrolled patients who underwent grayscale US and CEUS before surgery because of ovarian masses between July 2018 and September 2023, with available histopathologic or follow-up results. Two senior radiologists summarized the grayscale US and CEUS characteristics of all ovarian masses, including percentage of solidity, ascites, vascularity, and enhanced vessel morphology. These characteristics were then independently reviewed by radiologists with different experience to assess interobserver agreement. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC), while interobserver agreement was evaluated by intraclass correlation coefficient (ICC). RESULTS: A total of 26 children (median age: 10.1 [7.5, 11.7] years; age range: 0-14 years; benign: 15 patients) were included. The main characteristics of malignant ovarian tumors were abundant blood flow and twisted blood vessels within the mass, enhanced portion of the mass over 50 percent (all p < 0.001). The grayscale US combined with CEUS showed better diagnostic performance than the grayscale US alone (AUC = 0.99 [95% CI: 0.95, 1.00] vs AUC = 0.70 [95% CI: 0.50, 0.90] p < 0.001). A statistically significant AUC before and after CEUS was also shown between two junior radiologists (0.75 vs 0.92 and 0.69 vs 0.86, respectively, both p < 0.05). ICC of CEUS was better than that of grayscale US among radiologists. CONCLUSION: The combination of grayscale US and CEUS might improve the diagnostic accuracy in differentiating benign and malignant pediatric ovarian masses. CLINICAL RELEVANCE STATEMENT: Grayscale ultrasound combined with contrast-enhanced ultrasound can improve the diagnostic performance in the preoperative differentiation of benign and malignant ovarian lesions in a pediatric population. KEY POINTS: Correctly distinguishing benign from malignant ovarian masses in pediatric patients is critical for determining treatments. Grayscale combined with contrast-enhanced ultrasound (CEUS) differentiated benign and malignant pediatric ovarian masses better than grayscale US alone. Junior radiologists' diagnostic performances could be and were significantly improved with the application of CEUS.

10.
Semin Intervent Radiol ; 41(3): 241-245, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39165654

RESUMO

This review explores the applications of contrast-enhanced ultrasound (CEUS) in interventional radiology, focusing on its role in endoleak detection after endovascular abdominal aortic aneurysm repair (EVAR), periprocedural thermal ablation guidance, and transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). CEUS offers a dynamic assessment for the detection of endoleak following EVAR, facilitating accurate diagnosis and classification. In periprocedural thermal ablation, CEUS enhances target lesion delineation with the visualization of real-time perfusion changes, optimizing treatment strategies and reducing residual tumor rates. Finally, CEUS has demonstrated efficacy in intraprocedural evaluation and postprocedural follow-up in TACE for HCC, offering early detection of residual tumor enhancement and providing an alternative for patients with contraindications to contrast-enhanced computed tomography or magnetic resonance imaging. Overall, CEUS is a versatile and valuable tool with many applications to offer interventional radiologists enhanced diagnostic capabilities and improved patient management.

11.
Abdom Radiol (NY) ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39167237

RESUMO

PURPOSE: Ultrasound plays a central role in liver transplant evaluation. Acute, subacute, and chronic complications can be readily identified using grayscale and color Doppler ultrasound. Contrast-enhanced ultrasound adds a new dimension to liver transplant evaluation, depicting vascular and parenchymal processes with exquisite detail. In addition, emerging evidence suggests that contrast-enhanced ultrasound may allow for localization of biliary leak in select patients. We aimed to assess the use of multiparametric ultrasound-including grayscale, color and spectral Doppler, and contrast-enhanced ultrasound-in the setting of liver transplantation. METHODS: A literature review was performed using the MEDLINE bibliographic database through the National Library of Medicine. The following terms were searched and relevant citations assessed: "abdominal ultrasound," "contrast-enhanced ultrasound," "liver transplant," and "ultrasound." RESULTS: Grayscale and color Doppler ultrasound represent the mainstay imaging modalities for postoperative liver transplant evaluation. The addition of contrast enhancement plays a complementary role and can provide valuable information related to the allograft vasculature, parenchyma, and biliary tree. The appropriate implementation of grayscale, color Doppler, and contrast-enhanced ultrasound can optimize sensitivity, specificity, and accuracy for the detection of liver transplantation complications, including hepatic artery stenosis, biliary leakage, and infection. CONCLUSION: Multimodal sonographic evaluation is essential to identify postoperative complications in liver transplant recipients. Contrast-enhanced ultrasound may be of value in challenging cases, providing excellent anatomic delineation and reducing the risk of false-positive and false-negative diagnoses. A broad familiarity with appropriate applications of both nonenhanced and contrast-enhanced ultrasound may help radiologists optimize allograft assessment and improve patient outcomes.

12.
J Vasc Surg Cases Innov Tech ; 10(5): 101563, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39188692

RESUMO

Endovascular aortic aneurysm repair is widely used for the treatment of abdominal aortic aneurysm (AAA), but has a 10% to 40% incidence of type II endoleak during follow-up. There are various techniques to treat these endoleaks in the case of enlarging of the AAA, but the clinical effectiveness is low. In recent years, preemptive AAA sac embolization has shown some encouraging results with significant AAA shrinkage. However, the presence of embolic material can complicate continued endoleak detection making assessment of treatment outcome difficult. We investigate the ability of contrast-enhanced-ultrasound examination to detect endoleaks in patients undergoing preemptive coil embolization of the AAA sac.

13.
Artigo em Inglês | MEDLINE | ID: mdl-39174799

RESUMO

Advances in various imaging modalities for breast lesions have improved diagnostic capabilities not only for tumors but also for non-tumorous lesions. Contrast-enhanced ultrasound (CEUS) plays a crucial role not only in the differential diagnosis of breast lesions, identification of sentinel lymph nodes, and diagnosis of lymph node metastasis but also in assessing the therapeutic effects of neoadjuvant chemotherapy (NAC). In CEUS, two image interpretation approaches, i.e., qualitative analysis and quantitative analysis, are employed and applied in various clinical settings. In this paper, we review CEUS for breast lesions, including its various applications.

14.
Ultrasound Med Biol ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39181805

RESUMO

OBJECTIVE: To assess the diagnostic efficacy of the CEUS LI-RADS combined with a model constructed on the basis of age, sex, AFP, and PIVKA-II (ASAP) for the diagnosis of HCC in high-risk patients. METHODS: This retrospective study included 366 liver lesions from 366 patients who underwent liver CEUS. All liver lesions were characterized and categorized according to CEUS LI-RADS v2017. Two modified methods were applied: LR-3/4/M nodules accompanied by AFP > 200 ng/mL (Criterion 2) or ASAP model score > 0.5256 and CA 19-9 in the normal range (Criterion 3) were recategorized as LR-5. The reference criteria included histopathological or comprehensive imaging and the clinical follow-up results. The diagnostic performance was evaluated and compared by the sensitivity, specificity, PPV, and NPV. RESULTS: The incidence of HCC in LR-3, LR-4, LR-5, and LR-M was 33.3% (4/12), 86.4% (38/44), 98.5% (191/194) and 82.7% (81/98), respectively. After using Criterion 2 compared to CEUS LI-RADS v2017, the sensitivity of the modified LR-5 for diagnosing HCC increased from 60.8% to 70.7% (p < 0.01) with little effect on its specificity (94.2% vs. 92.3%, p = 1.00) or PPV (98.5% vs. 98.2%, p = 0.86). After using Criterion 3, the sensitivity of the modified LR-5 for the diagnosis of HCC was further improved to 86.9% (p < 0.01), and its specificity and PPV were not significantly changed (92.3% and 98.6%, both p > 0.05). CONCLUSION: CEUS LI-RADS combined with the serum biomarker-based ASAP model improved the sensitivity of LR-5 in diagnosing HCC with little effect on its specificity and PPV.

15.
Abdom Radiol (NY) ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39141152

RESUMO

Inflammatory Bowel Disease (IBD) is a lifelong chronic disease affecting any part of the gastrointestinal tract with a predilection for the terminal ileum. IBD patients require repeat imaging throughout the course of their disease, necessitating a safe, noninvasive, available, and repeatable method. Imaging is required at diagnosis, routine surveillance, and acute exacerbation of disease. Ultrasound imaging meets these demands with a high degree of accuracy and wide patient acceptance. Ultrasound provides high-resolution imaging and is excellent for detailed evaluation of the bowel wall and surrounding soft tissues. Regular greyscale bowel evaluation and color Doppler imaging now have accepted standards for evaluating disease activity based on wall thickness, perienteric inflammatory fat, and blood flow, which is invaluable in staging and grading disease. High-resolution dynamic real-time imaging on ultrasound has the ability to show functional as well as morphologic detail, including dysfunctional peristalsis associated with bowel stricture and incomplete mechanical bowel obstruction. Fibrostenotic and penetrating complications of IBD may be associated with an acute or chronic presentation that is easily assessed using ultrasound. Newer software technologies for ultrasound, including Contrast-Enhanced ultrasound and Shear wave elastography, have transformed ultrasound from a basic preliminary imaging technique into a highly sophisticated modality that is now competitive with CT and MR enterography for managing IBD patients. Our long experience with ultrasound of the bowel suggests that the new best practice would include ultrasound as the first test for evaluation of the bowel at any stage of the disease.

16.
Artigo em Inglês | MEDLINE | ID: mdl-39121113

RESUMO

BACKGROUND: Renal perfusion status remains poorly studied at the bedside during sepsis associated acute kidney injury (AKI). The aim of the study is to examine renal cortical and medullary perfusion using renal contrast enhanced ultrasound (CEUS) in septic patients. METHODS: In this single-center, prospective longitudinal study, septic patients were enrolled. Renal ultrasonography was performed within 24 hours of ICU admission (D1), then repeated at D3, D5 and D7. Each measurement consisted of three destruction replenishment sequences that were recorded for delayed analysis with dedicated software (Vuebox). Renal cortex and medulla perfusion were quantified by measuring time to peak (TTP). Receiver operating characteristic (ROC) analysis was used to evaluate 28-day renal prognosis. RESULTS: The study included 149 septic patients, including 70 non-AKI patients and 79 AKI patients. Both renal cortical and medullary TTP was longer in the AKI group than in the non-AKI group. The difference of TTP between renal cortex and medulla in AKI group was higher than that in the non-AKI group (p = 0.000). Medullary TTP on day 3 had the best performance in predicting the prognosis of 28-day renal function (AUC 0.673, 95% confidence interval 0.528-0.818, p = 0.024), and its cut-off value was 45 s with a sensitivity 52.2% and a specificity of 82.1%. Cortical TTP on day 3 also had the performance in predicting the prognosis of 28-day renal function (AUC 0.657, 95% confidence interval 0.514-0.800, p = 0.039), and its cut-off value was 33 s with a sensitivity 78.3% and a specificity of 55.0%. CONCLUSION: Renal medullary perfusion alterations differ from those in cortex, with the medulla is worse. Simultaneous and dynamic assessment of cortical and medullary microcirculatory flow alterations necessary. TTP on day 3, especially medullary TTP, seems to be a relatively stable and useful indicator, which correlates with 28-day renal function prognosis in septic patients. Early correction of renal cortical and medullary perfusion alterations reduces the incidence of adverse renal events.

17.
Artigo em Inglês | MEDLINE | ID: mdl-39164480

RESUMO

This narrative review aims to describe the current status of contrast-enhanced ultrasound (CEUS) in characterizing renal cystic lesion. The imaging techniques usually performed for their evaluation are ultrasonography (US), computed tomography (CT), and magnetic resonance imaging (MRI) with different criteria of application based on the individual case and the purpose of the examination. Generally, US, as a non-ionizing examination, is the first imaging modality performed and therefore the one that incidentally detects cystic lesions. CT is the most performed imaging modality for cystic lesion assessment before MRI evaluation. It provides better characterization and management and has been introduced into the Bosniak classification. In this context, CEUS is making its way for its characteristics and represents the emerging technique in this field. With these premises, the authors analyze the role of CEUS in the evaluation of renal cysts, starting with an explanation of the technique, describe its main advantages and limitations, and end with a discussion of its application in the Bosniak classification and management, following the current major guidelines.

18.
World J Radiol ; 16(7): 247-255, 2024 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-39086609

RESUMO

BACKGROUND: Hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC) represent the predominant histological types of primary liver cancer, comprising over 99% of cases. Given their differing biological behaviors, prognoses, and treatment strategies, accurately differentiating between HCC and ICC is crucial for effective clinical management. Radiomics, an emerging image processing technology, can automatically extract various quantitative image features that may elude the human eye. Reports on the application of ultrasound (US)-based radiomics methods in distinguishing HCC from ICC are limited. AIM: To develop and validate an ultrasomics model to accurately differentiate between HCC and ICC. METHODS: In our retrospective study, we included a total of 280 patients who were diagnosed with ICC (n = 140) and HCC (n = 140) between 1999 and 2019. These patients were divided into training (n = 224) and testing (n = 56) groups for analysis. US images and relevant clinical characteristics were collected. We utilized the XGBoost method to extract and select radiomics features and further employed a random forest algorithm to establish ultrasomics models. We compared the diagnostic performances of these ultrasomics models with that of radiologists. RESULTS: Four distinct ultrasomics models were constructed, with the number of selected features varying between models: 13 features for the US model; 15 for the contrast-enhanced ultrasound (CEUS) model; 13 for the combined US + CEUS model; and 21 for the US + CEUS + clinical data model. The US + CEUS + clinical data model yielded the highest area under the receiver operating characteristic curve (AUC) among all models, achieving an AUC of 0.973 in the validation cohort and 0.971 in the test cohort. This performance exceeded even the most experienced radiologist (AUC = 0.964). The AUC for the US + CEUS model (training cohort AUC = 0.964, test cohort AUC = 0.955) was significantly higher than that of the US model alone (training cohort AUC = 0.822, test cohort AUC = 0.816). This finding underscored the significant benefit of incorporating CEUS information in accurately distinguishing ICC from HCC. CONCLUSION: We developed a radiomics diagnostic model based on CEUS images capable of quickly distinguishing HCC from ICC, which outperformed experienced radiologists.

19.
Metabolites ; 14(8)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39195508

RESUMO

Hemorrhagic hydrocephalus is a common pathology in neonates with high mortality and morbidity. Current imaging approaches fail to capture the mechanisms behind its pathogenesis. Here, we discuss the processes underlying this pathology, the metabolic dysfunction that occurs as a result, and the ways in which these metabolic changes inform novel methods of clinical imaging. The imaging advances described allow earlier detection of the cellular and metabolic changes, leading to better outcomes for affected neonates.

20.
Vascular ; : 17085381241273221, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39135264

RESUMO

OBJECTIVES: The aim of this cross-sectional survey was to gather attitudes and practices of physicians from different countries regarding the implementation of contrast-enhanced ULTRAsound (CEUS) for vascular diseases in clinical practice as well as in academic research. METHODS: A web-based survey was developed in English, including 35 questions. Two-hundred sixty physicians were invited by email to fill in the survey anonymously on Google Forms using a dedicated link. The survey started on 25th February 2024 and was closed on 13th March 2024 (17 days). A reminder was sent after the first 10 days. In addition to descriptive statistics, sub-analyses of answers according to country of origin (Italy vs other States), years of experience (≤20 years vs > 20 years), and type of institution (Academic/University vs Non-Academic/Private) were also established a priori. RESULTS: A total of 121 practitioners from 20 countries completed our survey (response rate 121/260, 46%). Most responders were males (95/121, 78.5%). Most participants were vascular surgeons (118/121, 97.5%). CEUS was available in 87/121, 70.2% of the centers involved, even though a standardized protocol was present in 54/121, and 44% of surveyed institutions. Italian institutions presented greater CEUS availability (62/72, 86.1% vs 25/49, 51.0%; p = .001) and higher presence of standardized protocols (38/72, 52.8% vs 16/49, 32.6%; p = .022) than foreign institutions. The diagnostic tool was thought to be more useful for carotid artery stenosis in the postoperative phase, while for abdominal aortic aneurysms (AAAs) in the preoperative phase. For diagnosis and/or preoperative management of carotid stenosis 53/121, 44% of physicians believed that CEUS should be performed only in selected cases, while for AAA 42/121, 35% of them believed that it could be useful only for scientific purposes. Similarly, 99/121, 82% of participants answered that CEUS was usually prescribed in 0%-20% of the cases during the preoperative diagnostic pathway of patients with peripheral arterial disease. No differences between country of origin, years of experience, and type of institution were found for the reported items. There was also 106/121, 88% of respondents agreed upon the need for better integration of CEUS in current guidelines and 114/121, 94% of them upon the need for further studies. CONCLUSIONS: This ULTRA-VASC survey has demonstrated that CEUS is still rarely used in current practice for many vascular diseases despite the availability of this tool in most centers Future studies are needed, as well as enhanced guidance on the proper implementation of CEUS from guidelines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA