Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 334
Filtrar
1.
Int Arch Otorhinolaryngol ; 28(2): e294-e300, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618589

RESUMO

Introduction NB CE-Chirp LS was developed to improve the audiogram estimation by auditory brainstem response (ABR) thresholds during audiological assessment of infants and difficult to test children. However, before we know how the stimulus behaves in several types of hearing loss, it is important we know how the stimulus behaves in normal hearing infants. Objective To describe ABR thresholds with NB CE-Chirp LS stimulus for 500, 1,000, 2,000, and 4,000 Hz, as well as the amplitude and absolute latency for ABR thresholds. Methods Auditory brainstem response thresholds were evaluated with the Eclipse EP25 system. NB CE-Chirp LS was presented using an ER-3A insert earphone. EEG filter was 30 Hz high-pass and 1,500 Hz low-pass. The ABR threshold was defined as the lowest intensity capable of clearly evoke wave V, accompanied by an absent response 5 dB below. Results Eighteen normal hearing infants were evaluated. The mean and standard deviation (SD) of the ABR threshold (dB nHL) were: 23.8 (±4.2); 14.4 (±5.7); 6.0 (±5.0); and 7.0 (±5.9). The mean and SD of the absolute latency (ms) were: 8.86 (±1.12); 9.21 (±0.95); 9.44 (±0.78); and 9.64 (±0.52). The mean amplitude (nV) and SD were: 0.123 (±0.035); 0.127 (±0.039); 0.141 (±0.052); and 0.105 (±0.028), respectively, for 500, 1,000, 2,000 and 4,000 Hz. Conclusion Auditory brainstem response threshold with NB CE-Chirp LS reaches low levels, in special for high frequencies. It provides absolute latencies similar between frequencies with robust amplitude. The results obtained brings to the examiner more confidence in the results registered.

2.
J Laryngol Otol ; 138(6): 601-607, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38456283

RESUMO

OBJECTIVE: This study aimed to compare the peripheral-to-central auditory systems of people with coronavirus disease 2019 to a well-matched control group and examine the long-term effects of coronavirus disease 2019 on the auditory system. METHOD: Participants who were outpatients of coronavirus disease 2019 (n = 30) were compared with a well-matched control group (n = 30). Behavioural and electrophysiological tests were performed, and tests were repeated at six months in the coronavirus disease 2019 group. RESULTS: Statistically significant differences were observed in the right ear at 10 kHz (p = 0.007) and 12.5 kHz (p = 0.028), and in the left ear at 10 kHz (p = 0.040) and 12.5 kHz (p = 0.040) between groups. The groups had no difference regarding the other audiological test results (p > 0.05). CONCLUSION: Extended high-frequency thresholds were affected in the coronavirus disease 2019 patients. No other findings indicated that the peripheral-to-central auditory system was affected. The effect on extended high-frequency thresholds appeared permanent, but no clinically significant new, late-onset auditory system effects were observed.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Masculino , Feminino , Estudos Transversais , Pessoa de Meia-Idade , Adulto , Seguimentos , Limiar Auditivo/fisiologia , Estudos de Casos e Controles , SARS-CoV-2 , Idoso , Audiometria de Tons Puros
3.
Int Arch Otorhinolaryngol ; 28(1): e122-e128, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38322437

RESUMO

Introduction Peripheral hearing loss, besides causing inadequate auditory input, can lead to distortions in the tonotopic auditory map and reorganization of neural networks. Therefore, the processing of temporal aspects of a sound stimulus and, consequently, the effectiveness of human communication can be negatively impacted. Objective To test the temporal ordering and auditory resolution of people with mild and moderate sensorineural hearing loss and to compare them with the those of people with normal hearing. Methods A total of 19 right-handed individuals aged 16 to 59 years with mild to moderate postlingually acquired symmetric bilateral sensorineural hearing loss participated in the study. They were submitted to frequency and duration pattern tests and a random gap detection test. Results The mean correct response rate in the frequency pattern test was of 66.3%, and, in the duration pattern test, 71.7%. The mean threshold in the random gap detection test was of 14.1 ms. A comparison with the criteria established for normal subjects without peripheral hearing loss revealed that more than half the subjects had abnormal results in the temporal ordering test, while a smaller fraction had reduced temporal resolution. Conclusions The performance of the subjects with acquired sensorineural hearing loss was poorer than that of the participants without peripheral hearing loss. Their results on the temporal ordering test were also poorer than in the temporal resolution test, demonstrating the importance of analyzing both these auditory skills in people with peripheral hearing loss.

4.
Laryngoscope ; 134(6): 2864-2870, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38214403

RESUMO

OBJECTIVE: Pure tone audiometry (PTA) is the gold standard for hearing assessment. However, it requires access to specialized equipment. Smartphone audiometry applications (apps) have been developed to perform automated threshold audiometry and could allow patients to perform self-administered screening or monitoring. This study aimed to assess the validity and feasibility of patients using apps to self-assess hearing thresholds at home, with comparison to PTA. METHODS: A multi-center, prospective randomized study was conducted amongst patients undergoing PTA in clinics. Participants were randomly allocated to one of four publicly-available apps designed to measure pure tone thresholds. Participants used an app once in optimal sound-treated conditions and a further three times at home. Ear-specific frequency-specific thresholds and pure tone average were compared using Pearson correlation coefficient. The percentage of app hearing tests with results within ±10 dB of PTA was calculated. Patient acceptability was assessed via an online survey. RESULTS: One hundred thirty-nine participants submitted data. The results of two at-home automated smartphone apps correlated strongly/very strongly with PTA average and their frequency-specific median was within ±10 dB accuracy. Smartphone audiometry performed in sound-treated and home conditions were very strongly correlated. The apps were rated as easy/very easy to use by 90% of participants and 90% would be happy/very happy to use an app to monitor their hearing. CONCLUSION: Judicious use of self-performed smartphone audiometry was both valid and feasible for two of four apps. It could provide frequency-specific threshold estimates at home, potentially allowing assessments of patients remotely or monitoring of fluctuating hearing loss. LEVEL OF EVIDENCE: 2 Laryngoscope, 134:2864-2870, 2024.


Assuntos
Audiometria de Tons Puros , Aplicativos Móveis , Smartphone , Humanos , Masculino , Feminino , Audiometria de Tons Puros/instrumentação , Audiometria de Tons Puros/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Estudos de Viabilidade , Perda Auditiva/diagnóstico , Reprodutibilidade dos Testes , Adulto Jovem , Limiar Auditivo/fisiologia
5.
J Audiol Otol ; 28(1): 1-9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38254303

RESUMO

Hearing thresholds provide essential information and references about the human auditory system. This study aimed to identify changing trends in distributions of hearing threshold levels across ages by comparing the International Organization for Standardization (ISO) 7029 and newly available data after publishing ISO 7029. To compare ISO 7029 and newly available hearing threshold data after publishing ISO 7029, four country-specific datasets that presented average hearing threshold levels under conditions similar to ISO 7029 were utilized. For frequencies between 125 Hz and 8,000 Hz, the deviations of hearing threshold values by ages from the hearing threshold of the youngest age group for each data point were utilized. For frequencies from 9,000 Hz to 12,500 Hz, the median threshold information was utilized. Hearing threshold data reported after publishing ISO 7029 from the four countries were mostly similar to the ISO 7029 data but tended to deviate in some age groups and sexes. As national hearing threshold trends change, the following ISO 7029 revision suggests the need to integrate hearing threshold data from different countries.

6.
Int J Oral Maxillofac Surg ; 53(5): 376-381, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38061954

RESUMO

Brainstem evoked response audiometry (BERA) is the most established and recommended objective audiometric method for the clinical diagnosis of hearing impairment in high-risk infants. It is unclear whether infants with orofacial clefts meet the criteria for the high-risk group. This retrospective cohort study evaluated the need for diagnostic BERA in infants with cleft palate with or without cleft lip by assessing the predisposition to and diagnosis of congenital hearing impairment. Data from 122 patients treated at a single cleft centre were evaluated. BERA was conducted at the time of palate repair at 4-6 months of age. Clinical follow-up was analysed up to 4 years. The presence of a syndrome was examined as a risk factor for congenital hearing impairment. Among the 122 patients, four had congenital sensorineural or mixed hearing loss requiring hearing aids. All affected patients had syndromes in addition to the cleft. Most patients with elevated hearing thresholds had transient conductive hearing loss. Most suspected sensorineural hearing loss initially diagnosed was refuted. However, a higher incidence of sensorineural hearing loss was found in patients with syndromic clefts, supporting the diagnostic use of BERA with initial surgery only in patients with syndromic clefts.


Assuntos
Fenda Labial , Fissura Palatina , Perda Auditiva Neurossensorial , Perda Auditiva , Lactente , Humanos , Fenda Labial/cirurgia , Fissura Palatina/complicações , Fissura Palatina/cirurgia , Audiometria de Resposta Evocada , Estudos Retrospectivos , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva/epidemiologia , Tronco Encefálico
7.
HNO ; 72(Suppl 1): 25-32, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37656221

RESUMO

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Humanos , Fala , Implante Coclear/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Medidas de Resultados Relatados pelo Paciente
8.
Distúrb. comun ; 35(3): 63637, 25/10/2023.
Artigo em Inglês, Português | LILACS | ID: biblio-1526043

RESUMO

Introdução: A COVID-19 pode afetar o sistema auditivo, justificando a avaliação da audição de indivíduos infectados. Objetivo: analisar a via auditiva até o tronco encefálico de indivíduos acometidos por COVID-19 comparados ao grupo controle. Método: Estudo observacional transversal analítico realizado em uma amostra não probabilística de adultos que tiveram COVID-19, que foram comparados com um grupo controle, sem queixa auditiva. A avaliação consistiu em: medidas de imitância acústica, audiometria tonal liminar (ATL), emissões otoacústicas evocadas por estímulo transiente (EOET) e potencial evocado auditivo de tronco encefálico (PEATE). Resultados: Foram avaliados 77 indivíduos, sendo, 41 participantes do grupo COVID-19 (idade média de 26,3) e 36 do grupo controle (idade média de 25,8). Os limiares auditivos estavam dentro dos padrões da normalidade para todos os indivíduos do grupo COVID-19, sendo significativamente maiores para as frequências de 1000, 2000 e 3000 Hz à direita. A amplitude das EOET foi significativamente menor na banda de frequência de 1500 à direita. Houve correlação significativa e negativa para as frequências de 1000 Hz e 3000 Hz à direita e para as frequências de 1000, 2000 e 3000 Hz à esquerda, entre EOET e ATL. Foi verificado aumento da latência absoluta da onda I, do PEATE, na orelha esquerda. Conclusão: a COVID-19 afetou locais específicos do sistema auditivo. Houve diminuição da acuidade auditiva e do funcionamento das células ciliadas externas da cóclea, bem como aumento do tempo de condução neural do som na porção distal do VII par craniano à esquerda. (AU)


Introduction: COVID-19 can affect the auditory system, justifying the evaluation of the hearing of infected individuals. Objective: to analyze the auditory pathway to the brainstem of individuals affected by COVID-19 compared to the control group. Method: Analytical cross-sectional observational study carried out in a non-probabilistic sample of adults who had COVID-19, who were compared with a control group, without hearing complaints. The evaluation consisted of: acoustic immittance measurements, pure tone audiometry (PTA), transient stimulus-evoked otoacoustic emissions (TEOAE) and brainstem auditory evoked potential (BAEP). Results: 77 individuals were evaluated, 41 participants in the COVID-19 group (average age of 26.3) and 36 in the control group (average age of 25.8). Hearing thresholds were within normal limits for all individuals in the COVID-19 group, being significantly higher for the frequencies of 1000, 2000 and 3000 Hz on the right. TEOAE amplitude was significantly lower in the 1500 frequency band on the right. There was a significant and negative correlation for the frequencies of 1000 Hz and 3000 Hz on the right and for the frequencies of 1000, 2000 and 3000 Hz on the left, between TEOAE and PTA. An increase in the absolute latency of wave I, of the BAEP, was observed in the left ear. Conclusion: COVID-19 affected specific locations in the auditory system. There was a decrease in auditory acuity and the functioning of the outer hair cells of the cochlea, as well as an increase in the neural conduction time of sound in the distal portion of the VII cranial nerve on the left. (AU)


Introducción: COVID-19 puede afectar el sistema auditivo, justificando la evaluación de la audición de individuos infectados. Objetivo: analizar la vía auditiva hacia el tronco encefálico de individuos afectados por COVID-19 en comparación con el grupo control. Método: Estudio observacional analítico transversal realizado en una muestra no probabilística de adultos que padecieron COVID-19, quienes fueron comparados con un grupo control, sin escuchar quejas. La evaluación consistió en: mediciones de inmitancia acústica, audiometría de tonos puros (ATP), otoemisiones acústicas provocadas por estímulos transitorios (OAET) y potenciales evocados auditivos del tronco encefálico (PEATE). Resultados: Se evaluaron 77 individuos, 41 participantes en el grupo COVID-19 (edad promedio de 26,3 años) y 36 en el grupo control (edad promedio de 25,8 años). Los umbrales de audición estaban dentro de los límites normales para todos los individuos del grupo de COVID-19, siendo significativamente más altos para las frecuencias de 1000, 2000 y 3000 Hz de la derecha. La amplitud de OAET fue significativamente menor en la banda de frecuencia de 1500 de la derecha. Hubo correlación significativa y negativa para las frecuencias de 1000 Hz y 3000 Hz a la derecha y para las frecuencias de 1000, 2000 y 3000 Hz a la izquierda, entre OAET y ATP. Se observó un aumento de la latencia absoluta de la onda I, del PEATE, en el oído izquierdo. Conclusión: COVID-19 afectó ubicaciones específicas del sistema auditivo. Hubo una disminución de la agudeza auditiva y del funcionamiento de las células ciliadas externas de la cóclea, así como un aumento del tiempo de conducción neural del sonido en la porción distal del VII par craneal izquierdo. (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , COVID-19/complicações , Audição/fisiologia , Estudos de Casos e Controles , Estudos Transversais , Perda Auditiva/diagnóstico , Perda Auditiva/etiologia , Testes Auditivos
9.
HNO ; 71(9): 583-591, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37540233

RESUMO

BACKGROUND: Patients with a cochlear implant (CI) should be evaluated for a new speech processor every 6 years. The aim of this analysis was to assess the subjective and audiological benefit of upgrades. METHODS: Speech understanding and subjective benefit were analyzed in 99 patients with the old and the new speech processor after 4 weeks of wearing. Speech understanding was assessed using the Freiburg monosyllabic test in quiet (FBE) at 65 dB and 80 dB, and the Oldenburg Sentence Test (OLSA) at 65 dB noise with adaptive speech sound level. The Abbreviated Profile of Hearing Aid Benefit (APHAB) was used to assess subjective hearing impairment, and the Audio Processor Satisfaction Questionnaire (APSQ) was used to assess subjective satisfaction. RESULTS: The speech processor upgrade resulted in a significant improvement of speech understanding in quiet at 65 dB (mean difference 8.9 ± 25.9 percentage points, p < 0.001) and 80 dB (mean difference 8.1 ± 29.7 percentage points, p < 0.001) and in noise (mean difference 3.2 ± 10.7 dB signal-to-noise ratio [S/N], p = 0.006). Using the APHAB, a significant improvement (mean difference 0.07 ± 0.16, p < 0.001) in hearing impairment was demonstrated in all listening situations. The APSQ showed significantly higher patient satisfaction with the new speech processor (mean difference 0.42 ± 1.26, p = 0.006). A comparative assessment of the benefit based on subjective and speech audiometric results identified a proportion of patients (35-42%) who subjectively benefited from the upgrade but had no measurable benefit based on speech audiometry. CONCLUSION: There was a significant improvement in audiologically measurable and subjectively reflected speech understanding and patient satisfaction after the upgrade. In patients with only a small improvement in audiologically measurable speech understanding, the subjective benefit should also be assessed with validated measurement instruments in order to justify an upgrade to the payers in the health sector.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva , Percepção da Fala , Humanos , Fala , Implante Coclear/métodos , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Medidas de Resultados Relatados pelo Paciente
10.
Brain Sci ; 13(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37371447

RESUMO

Recent studies involving guinea pigs have shown that noise can damage the synapses between the inner hair cells and spiral ganglion neurons, even with normal hearing thresholds-which makes it important to investigate this kind of impairment in humans. The aim was to investigate, with multiple audiological assessments, the auditory function of normal hearing workers exposed to occupational noise. Altogether, 60 workers were assessed (30 in the noise-exposure group [NEG], who were exposed to occupational noise, and 30 in the control group [CG], who were not exposed to occupational noise); the workers were matched according to age. The following procedures were used: complete audiological assessment; speech recognition threshold in noise (SRTN); speech in noise (SN) in an acoustic field; gaps-in-noise (GIN); transient evoked otoacoustic emissions (TEOAE) and inhibitory effect of the efferent auditory pathway; auditory brainstem response (ABR); and long-latency auditory evoked potentials (LLAEP). No significant difference was found between the groups in SRTN. In SN, the NEG performed worse than the CG in signal-to-noise ratio (SNR) 0 (p-value 0.023). In GIN, the NEG had a significantly lower percentage of correct answers (p-value 0.042). In TEOAE, the NEG had smaller amplitude values bilaterally (RE p-value 0.048; LE p-value 0.045) and a smaller inhibitory effect of the efferent pathway (p-value 0.009). In ABR, the NEG had greater latencies of wave V (p-value 0.017) and interpeak intervals III-V and I-V in the LE (respective p-values: 0.005 and 0.04). In LLAEP, the NEG had a smaller P3 amplitude bilaterally (RE p-value 0.001; LE p-value 0.002). The NEG performed worse than the CG in most of the assessments, suggesting that the auditory function in individuals exposed to occupational noise is impaired, even with normal audiometric thresholds.

11.
J Audiol Otol ; 27(3): 133-138, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37340773

RESUMO

BACKGROUND AND OBJECTIVES: The speech tests used to evaluate language performance in patients with bilateral deafness (BiD) and cochlear implant (CI) are problematic if applied to patients with single-sided deafness (SSD) because normal ear hearing should be excluded. Thus, we investigated the feasibility of using wireless connection to evaluate speech intelligibility of the CI ear in patients with SSD. Subjects and. METHODS: Patients with BiD and SSD were administered the word recognition scores (WRS) and speech intelligibility tests using an iPadbased wireless connection and conventional methods. To exclude normal side hearing in patients with SSD, masking noise and "plugged and muffed" method were used in the WRS and speech intelligibility tests, respectively. RESULTS: In patients with BiD, the WRS and speech intelligibility tests results using wireless connection and conventional methods were similar. In patients with SSD, the WRS using masking noise in the normal hearing ear was similar to that of using wireless connection. However, 3 of 11 patients with SSD showed under-masked results if using the "plugged and muffed" method. CONCLUSIONS: Speech intelligibility testing using wireless connection is a convenient and reliable method for evaluating CI performance in patients with SSD. The "plugged and muffed" method is not recommended for evaluating CI performance in patients with SSD.

12.
Distúrb. comun ; 35(1): e57675, 01/06/2023.
Artigo em Português | LILACS | ID: biblio-1436211

RESUMO

Introdução: O zumbido é uma ilusão auditiva consciente, uma sensação sonora não relacionada com uma fonte externa de estimulação. Objetivos: Caracterizar a Acufenometria, Limiar Diferencial de Mascaramento, o questionário de qualidade de vida Inventário de Desvantagem do Zumbido e Potencial Auditivo de Tronco Encefálico em adultos normo-ouvintes com zumbido, com a finalidade de comparar seus achados. Método: Vinte indivíduos do sexo feminino e masculino, entre 20 e 60 anos de idade, normo-ouvintes com queixa de zumbido, foram submetidos ao Acufenometria, Limiar Diferencial de Mascaramento, Inventário de Desvantagem do Zumbido e Potencial Evocado Auditivo de Tronco Encefálico. Resultados: AAcufenometriarevelou que o pitch médio foi de 4,3 KHz à orelha direita e 4,6 KHz à orelha esquerda. O loudness médio foi de 21,7 dBNS à orelha direita e 23,5 dBNS à orelha esquerda. O Limiar Diferencial de Mascaramento médio mostrou-se alterado. O Inventário de Desvantagem do Zumbido médio correspondeu à classificação de grau leve. O Potencial Evocado Auditivo de Tronco Encefálico apresentou parâmetros dentro da normalidade bilateralmente. Conclusão: Constatou-se que adultos normo-ouvintes com queixa de zumbido apresentam zumbido de pitch agudo bilateral com discreto impacto na qualidade de vida, condução adequada das vias auditivas até o tronco encefálico e comprometimento na identificação de sons na presença de ruído, demonstrando que o zumbido pode ter repercussões nas habilidades auditivas centrais. (AU)


Introduction: Tinnitus is a conscious auditory illusion, a sound perception unrelated to any external stimulus source. Objectives: To characterize the Acuphenometry, Masking Level Difference, the quality of life questionnaire Tinnitus Handicap Inventory and Auditory Brainstem Response in normal hearing adults with tinnitus, with the purpose of comparing the findings. Method: Twenty female and male individuals, between 20 and 60 years of age, normal hearing with complaints of tinnitus, underwent Acuphenometry, Masking Level Difference, Tinnitus Handicap Inventory and Auditory Brainstem Response. Results: The Acuphenometry showed the average pitch was 4.3 KHz to the right ear and 4.6 KHz to the left ear. The average loudness was 21.7 dBSL to the right ear and 23.5 dBs to the left ear. The average Masking Level Difference was altered. The average Tinnitus Handicap Inventory corresponded to the classification of mild grade. Auditory Brainstem Response showed parameters within normal range bilaterally. Conclusion: It was found that normal hearing adults with tinnitus complaints have bilateral acute pitch tinnitus with a slight impact on quality of life, appropriate conduction of auditory pathways to the brainstem and impaired identification of sounds in the presence of noise, demonstrating that tinnitus can have repercussions on central auditory skills. (AU)


Introducción: El tinnitus es una ilusión auditiva consciente, una sensación de sonido no relacionada con una fuente externa de estimulación. Objetivos: Caracterizar la coincidencia de tono y volumen, el umbral de enmascaramiento diferencial, el inventario de minusvalía para acúfenos y el potencial auditivo del tronco encefálico en adultos normoyentes con acúfenos, con el fin de comparar sus hallazgos. Método:Veinte sujetos masculinos y femeninos, con edades entre 20 y 60 años, audición normal con tinnitus, fueron sometidos a acúfenos, Umbral de Enmascaramiento Diferencial, Inventario de Desventajas de Tinnitus y Potenciales Evocados Auditivos del Tronco Encefalico. Resultados: La combinación de tono y volumen reveló que el tono promedio era de 4,3 KHz en el oído derecho y de 4,6 KHz en el oído izquierdo. Mientras que el volumen medio fue de 21,7 dBNS para el oído derecho y de 23,5 dBNS para el oído izquierdo. Se modificó el umbral diferencial de enmascaramiento promedio. El Inventario de Desventajas de Tinnitus promedio correspondió a la clasificación de grado leve. El Potenciales Evocados Auditivos del Tronco Encefalico presentó parámetros dentro del rango normal bilateralmente. Conclusión:Se encontró que los adultos normooyentes con quejas de tinnitus presentan tinnitus de tono alto bilateral con leve impacto en la calidad de vida, conducción adecuada de las vías auditivas al tronco encefálico y deterioro en la identificación de sonidos en presencia de ruido, demostrando que Tinnitus puede tener repercusiones en las habilidades auditivas centrales. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Zumbido/etiologia , Testes Auditivos , Mascaramento Perceptivo , Limiar Auditivo , Inquéritos e Questionários , Potenciais Evocados Auditivos do Tronco Encefálico
13.
Noise Health ; 25(117): 104-112, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37203127

RESUMO

Objective: The goal is to implement the developed speech material in a hearing test to assess auditory fitness for duty (AFFD), specifically in areas where the intelligibility of spoken commands is essential. Design: In study 1, a speech corpus with equal intelligibility was constructed using constant stimuli to test each target word's psychometric functions. Study 2 used an adaptive interleaving procedure to maximize equalized terms. Study 3 used Monte Carlo simulations to determine speech test accuracy. Study sample: Study 1 (n = 24) and study 2 (n = 20) were completed by civilians with normal hearing. Study 3 ran 10,000 simulations per condition across various conditions varying in slopes and speech recognition thresholds (SRTs). Results: Studies 1 and 2 produced three 8-word wordlists. The mean, standard deviation in dB SNR is -13.1 1.2 for wordlist 1, -13.7 1.6 for wordlist 2, and -13.7 1.3 for wordlist 3, with word SRTs within 3.4 dB SNR. Study 3 revealed that a 6 dB SNR range is appropriate for equally understandable speech using a closed-set adaptive technique. Conclusion: The developed speech corpus may be used in an AFFD measure. Concerning the homogeneity of the speech in noise test material, care should be taken when generalizing and using ranges and standard deviations from multiple tests.


Assuntos
Inteligibilidade da Fala , Percepção da Fala , Limiar Auditivo , Testes Auditivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Teste do Limiar de Recepção da Fala/métodos , Humanos
14.
Front Neurosci ; 17: 1151776, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37139520

RESUMO

Among the many questions regarding the ability to effortlessly name musical notes without a reference, also known as absolute pitch, the neural processes by which this phenomenon operates are still a matter of debate. Although a perceptual subprocess is currently accepted by the literature, the participation of some aspects of auditory processing still needs to be determined. We conducted two experiments to investigate the relationship between absolute pitch and two aspects of auditory temporal processing, namely temporal resolution and backward masking. In the first experiment, musicians were organized into two groups according to the presence of absolute pitch, as determined by a pitch identification test, and compared regarding their performance in the Gaps-in-Noise test, a gap detection task for assessing temporal resolution. Despite the lack of statistically significant difference between the groups, the Gaps-in-Noise test measures were significant predictors of the measures for pitch naming precision, even after controlling for possible confounding variables. In the second experiment, another two groups of musicians with and without absolute pitch were submitted to the backward masking test, with no difference between the groups and no correlation between backward masking and absolute pitch measures. The results from both experiments suggest that only part of temporal processing is involved in absolute pitch, indicating that not all aspects of auditory perception are related to the perceptual subprocess. Possible explanations for these findings include the notable overlap of brain areas involved in both temporal resolution and absolute pitch, which is not present in the case of backward masking, and the relevance of temporal resolution to analyze the temporal fine structure of sound in pitch perception.

15.
HNO ; 71(Suppl 1): 53-59, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37140615

RESUMO

BACKGROUND: If sufficient speech discrimination is no longer achieved with conventional hearing systems, an audiological indication for a cochlear implant (CI) is given. However, there are no established target criteria for CI aftercare with regard to the level of speech comprehension to be achieved. The aim of this study is to validate an existing predictive model for speech comprehension after CI provision. This is applied to different patient groups. MATERIALS AND METHODS: The prospective study included 124 postlingually deaf adults. The model is based on preoperative maximum monosyllabic recognition score, aided monosyllabic recognition score at 65 dBSPL, and age the time of implantation. The model was investigated with regard to prediction accuracy for monosyllabic recognition with CI after 6 months. RESULTS: Mean speech discrimination improved from 10% with hearing aid to 65% with CI after 6 months, with a statistically significant improvement in 93% of cases. Deterioration of aided unilateral speech discrimination was not observed. The mean prediction error was 11.5 percentage points in the cases with preoperative scores better than zero and 23.2 percentage points in all other cases. CONCLUSION: Cochlear implantation should also be considered in patients with moderately severe to severe hearing loss and insufficient speech discrimination with hearing aids. The model based on preoperatively measured data for predicting speech discrimination with CI can be used in preoperative consultation and in the context of postoperative quality assurance.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Percepção da Fala , Adulto , Humanos , Estudos Prospectivos , Fala
16.
Int J Pediatr Otorhinolaryngol ; 169: 111540, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37116274

RESUMO

OBJECTIVES: Analyze the inhibitory effect of contralateral noise on transient otoacoustic emissions in infants with congenital syphilis (CS). METHODS: Cross-sectional study, approved by the Research Ethics Committee n° 3.360.991. Infants with treated CS at birth and infants without risk indicators for hearing impairment were selected. Both groups had the waves I, III and V presence at 80 dB nHL with click BAEP and the presence of response in the nonlinear TEOAEs at 80 dB NPS bilaterally. For suppression, TEOAE were analyzed without the contralateral noise, with the linear stimulus at 60 dB SPL. The neonates who presented a response in three frequencies per ear performed the second TEOAE collection with the contralateral white noise at an intensity of 60 dB SPL. Inferential analysis were performed using the Mann-Whitney and Wilcoxon test, adopting a significance level p < 0.05. RESULTS: The sample consisted of 30 subjects divided into two groups, the Study Group (SG), consisting of 16 infants, and the Control Group (CG), consisting of 14 infants with no risk indicators for hearing loss. No differences were observed between the groups and the inhibition values, in the SG 30.8% presented inhibition and 25% for the CG in the right ear, in the left ear it was 46.7% in the SG and 38.5% in the CG. The SG demonstrated greater inhibition in the RE for the frequency bands from 1.5 to 4 KHz. CONCLUSIONS: The analyses adopted in this study point out that the inhibitory effect of contralateral noise on TEOAEs in infants with CS does not differ from infants without risk indicators for hearing loss.


Assuntos
Surdez , Sífilis Congênita , Recém-Nascido , Humanos , Lactente , Emissões Otoacústicas Espontâneas/fisiologia , Estudos Transversais , Ruído , Estimulação Acústica
17.
Telemed J E Health ; 29(10): 1433-1445, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36862527

RESUMO

Background: Hearing loss is one of the most prevalent chronic health conditions. Traditional pure tone audiometry (PTA) is the gold standard for hearing loss screening, but is not widely available outside specialized clinical centers. Mobile health (mHealth)-based audiometry could improve access and cost-effectiveness, but its diagnostic accuracy varies widely between studies. Therefore, we aimed to evaluate the diagnostic accuracy of mHealth-based audiometry for hearing loss screening in adults compared with traditional PTA. Methods: Ten English and Chinese databases were searched from inception until April 30, 2022. Two researchers independently selected studies, extracted data, and appraised methodological quality. The bivariate random-effects model was adopted to estimate the pooled sensitivity and specificity for each common threshold (i.e., the threshold to define mild or moderate hearing loss). The hierarchical summary receiver operating characteristic model was used to assess the area under the receiver operating characteristic curve (AUC) across all thresholds. Results: Twenty cohort studies were included. Only one study (n = 109) used the mHealth-based speech recognition test (SRT) as the index test. Nineteen studies (n = 1,656) used mHealth-based PTA as the index test, and all of them were included in the meta-analysis. For detecting mild hearing loss, the pooled sensitivity and specificity were 0.91 (95% confidence interval [CI] 0.80-0.96) and 0.90 (95% CI 0.82-0.94), respectively. For detecting moderate hearing loss, the pooled sensitivity and specificity were 0.94 (95% CI 0.87-0.98) and 0.87 (95% CI 0.79-0.93), respectively. For all PTA thresholds, the AUC was 0.96 (95% CI 0.40-1.00). Conclusions: mHealth-based audiometry provided good diagnostic accuracy for screening both mild and moderate hearing loss in adults. Given its high diagnostic accuracy, accessibility, convenience, and cost-effectiveness, it shows enormous potential for hearing loss screening, particularly in primary care sites, low-income regions, and settings with in-person visit limitations. Further work should evaluate the diagnostic accuracy of the mHealth-based SRT tests.


Assuntos
Perda Auditiva , Telemedicina , Adulto , Humanos , Perda Auditiva/diagnóstico , Audiometria de Tons Puros , Sensibilidade e Especificidade , Estudos de Coortes
18.
HNO ; 71(5): 311-318, 2023 May.
Artigo em Alemão | MEDLINE | ID: mdl-36943431

RESUMO

BACKGROUND: If sufficient speech discrimination is no longer achieved with conventional hearing systems, an audiological indication for a cochlear implant (CI) is given. However, there are no established target criteria for CI aftercare with regard to the level of speech comprehension to be achieved. The aim of this study is to validate an existing predictive model for speech comprehension after CI provision. This is applied to different patient groups. MATERIALS AND METHODS: The prospective study included 124 postlingually deaf adults. The model is based on preoperative maximum monosyllabic recognition score, aided monosyllabic recognition score at 65 dBSPL, and age the time of implantation. The model was investigated with regard to prediction accuracy for monosyllabic recognition with CI after 6 months. RESULTS: Mean speech discrimination improved from 10% with hearing aid to 65% with CI after 6 months, with a statistically significant improvement in 93% of cases. Deterioration of aided unilateral speech discrimination was not observed. The mean prediction error was 11.5 percentage points in the cases with preoperative scores better than zero and 23.2 percentage points in all other cases. CONCLUSION: Cochlear implantation should also be considered in patients with moderately severe to severe hearing loss and insufficient speech discrimination with hearing aids. The model based on preoperatively measured data for predicting speech discrimination with CI can be used in preoperative consultation and in the context of postoperative quality assurance.


Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Percepção da Fala , Adulto , Humanos , Estudos Prospectivos , Fala
19.
Rev. otorrinolaringol. cir. cabeza cuello ; 83(1): 15-23, mar. 2023. tab
Artigo em Espanhol | LILACS | ID: biblio-1431948

RESUMO

Introducción: Las pruebas de patrones de frecuencia y patrones de duración son consideradas los gold standard de evaluación del ordenamiento auditivo temporal. A pesar de su amplia difusión, la extensión y duración de estas pruebas dificultan su utilización dentro de baterías de evaluación del procesamiento auditivo. Sin embargo, dadas sus características estructurales, pareciera ser posible reducirlas sin perder su precisión diagnóstica. Objetivo: Determinar las propiedades diagnósticas de versiones abreviadas de las pruebas de patrones de frecuencia y patrones de duración. Material y Método: Se realizó un estudio transversal de diseño observacional analítico. Se evaluaron 166 oídos de 88 sujetos con edades entre 18 y 33 años, los cuales fueron clasificados con normalidad o alteración del ordenamiento auditivo temporal. Se utilizaron las pruebas originales de Auditec de 30 ítems por oído como referencia y los primeros 10 ítems de cada oído como versión abreviada. Resultados: La versión abreviada de la prueba de patrones de frecuencia obtuvo una sensibilidad de un 94,33%, una especificidad del 94,29% y un área bajo la curva ROC de 0,980. La versión abreviada de la prueba de patrones de duración obtuvo una sensibilidad de un 89,58%, especificidad del 71,88% y un área bajo la curva ROC de 0,916. Ambas versiones tuvieron un índice de concordancia adecuado. Conclusiones: Las versiones abreviadas de la prueba de patrones de frecuencia y patrones de duración cuentan con excelentes propiedades diagnósticas para la evaluación del ordenamiento auditivo temporal y pueden ser utilizadas de manera intercambiable con las versiones originales.


Introduction: The frequency and duration pattern tests are considered the gold standard for assessing auditory temporal ordering. Despite their wide dissemination, the length and duration of these tests make it difficult to use them within auditory processing assessment batteries. However, given their structural characteristics, reducing them without losing their diagnostic accuracy seems possible. Aim: Determine the diagnostic properties of abbreviated versions of the Frequency Patterns and Duration Patterns tests. Material and Method: A cross-sectional study with an analytical observational design was carried out. 166 ears of 88 subjects aged between 18 and 33 years were evaluated, classified as normal or altered in temporal auditory order. The original Auditec tests of 30 items per ear were used as a reference, and the first 10 items of each ear as an abbreviated version. Results: The abbreviated version of the frequency patterns test obtained a sensitivity of 94.33%, a specificity of 94.29%, and an area under the ROC curve of 0.980. The abbreviated version of the duration pattern test obtained a sensitivity of 89.58%, a specificity of 71.88%, and an area under the ROC curve of 0.916. Both versions had an adequate concordance index. Conclusion: The abbreviated versions of the frequency patterns and duration patterns test have excellent diagnostic properties for assessing auditory temporal ordering and can be used interchangeably with the original versions.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Percepção Auditiva/fisiologia , Transtornos da Percepção Auditiva/diagnóstico , Estudos Transversais , Curva ROC , Testes Auditivos/métodos
20.
Acta Otolaryngol ; 143(1): 31-36, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36661392

RESUMO

BACKGROUND: Zika virus (ZIKV) infection can result in hearing loss in babies, consequently, audiological monitoring is necessary. AIMS: This study aimed to evaluate the frequency of hearing impairment in neonates and children exposed to ZIKV during the intrauterine period. MATERIALS AND METHODS: A cohort of 30 children born to mothers infected with ZIKV during pregnancy (March 2016-January 2017) underwent repeated hearing assessments performed 48 h after birth. Universal Newborn Hearing Screening revealed normal results in all children at 6, 13, 24, and 36 months. Children were divided into two subgroups based on real-time polymerase chain reaction: RT-PCR(+) and RT-PCR(-). RESULTS: At 24 months, the cumulative incidence of hearing alteration was 57.1%. There was no significant difference in the detection of hearing alteration between RT-PCR(+) and (-) groups. None of the children had sensorineural hearing loss. CONCLUSIONS AND SIGNIFICANCE: None of the children had sensorineural hearing loss. Total incidence conductive type (per 1000 live births), RT-PCR ZIKV (-) 2.2, prevalence 20% and RT-PCR ZIKV 3.1, prevalence 35.7%.The incidence of hearing alteration was highest at 24 months of age (57.1%, n = 8; only conductive type).


Assuntos
Perda Auditiva Neurossensorial , Complicações Infecciosas na Gravidez , Infecção por Zika virus , Zika virus , Lactente , Recém-Nascido , Gravidez , Feminino , Humanos , Criança , Infecção por Zika virus/complicações , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/epidemiologia , Estudos Longitudinais , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/epidemiologia , Estudos de Coortes , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Neurossensorial/etiologia , Audição
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...