Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(5): 975-983, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38482937

RESUMO

INTRODUCTION: Lesion size index (LSI) was introduced with the use of Tacticath™ and as a surrogate of lesion quality. The metric used to achieve the predetermined values involves combined information of contact force (CF), power and radiofrequency time. Rapid atrial pacing (RAP) and high-frequency low-tidal volume ventilation (HFLTV) independently or in combination improve catheter stability and CF and quality of lesions. Data of the impact of body weight adjusted HFLTV ventilation strategy associated with RAP in the lesion metrics still lacking. The study aimed to compare the results of high-power short-duration (HPSD) atrial fibrillation ablation using simultaneous weight adjusted HFLTV and RAP and standard ventilation (SV) protocol. METHODS: Prospective, nonrandomized study with 136 patients undergoing de novo ablation divided into two groups; 70 in RAP (100 ppm) + HFLTV with 4 mL/kg of tidal volume and 25 breaths/min (group A) and 66 patients with SV in intrinsic sinus rhythm (group B). Ablation using 50 W, CF of 5-10 g/10-20 g and 40 mL/minute flow rate on the posterior and anterior left atrial wall, respectively. RESULTS: No procedure-related complications. Group A: Mean LSI points 70 ± 16.5, mean total lower LSI 3.4 ± 0.5, mean total higher LSI 8.2 ± 0.4 and mean total LSI 5.6 ± 0.6. Anterior and posterior wall mean total LSI was 6.0 ± 0.4 and 4.2 ± 0.3, respectively. Mean local impedance drop (LID) points were 118.8 ± 28.4, mean LID index (%) 12.9 ± 1.5, and mean LID < 12% points 55.9 ± 23.8. Anterior and posterior wall mean total LID index were 13.6 ± 2.0 and 11.9 ± 1.7, respectively. Recurrence in 11 (15.7%) patients. Group B: Mean LSI points 56 ± 2.7, mean total lower LSI 2.9 ± 0.7, mean total higher LSI 6.9 ± 0.9, and mean total LSI 4.8 ± 0.8. Anterior and posterior wall mean total LSI was 5.1 ± 0.3 and 3.5 ± 0.5, respectively. Mean LID points were 111.4 ± 21.5, mean LID index (%) 11.4 ± 1.2, and mean LID < 12% points 54.9 ± 25.2. Anterior and posterior wall mean total LID index were 11.8 ± 1.9 and 10.3 ± 1.7, respectively. Recurrence in 14 (21.2%) patients. Mean follow up was 15.2 ± 4.4 months. CONCLUSION: Weight adjusted HFLTV ventilation with RAP HPSD ablation produced lower recurrence rate and better LSI and LID parameters in comparison to SV and intrinsic sinus rhythm.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Volume de Ventilação Pulmonar , Humanos , Feminino , Projetos Piloto , Masculino , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Ablação por Cateter/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Frequência Cardíaca , Estimulação Cardíaca Artificial , Peso Corporal
2.
J Interv Card Electrophysiol ; 67(6): 1399-1406, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38261105

RESUMO

BACKGROUND: Center volume and operator experience/training are important factors impacting outcomes in AFib CA. Setting for RF delivery (power, duration, and contact force) associated with better outcomes remains to be determined. METHODS: This is an observational, longitudinal, and retrospective study. All consecutive procedures performed between December 12, 2013, and March 9, 2023, in a low-volume private center in Latin America were analyzed. Procedure characteristics and outcomes were compared between STD and vHPSD. RESULTS: Two hundred ten procedures were performed on 194 patients. Median annual number of procedures was 19 (7-29). Median age was 62 (52-68), and majority were male (71%). Median procedure duration was 155 (125-195) min, mean fluoroscopy time 32.8 ± 15 min and mean fluoroscopy dose 373.5 ± 208.9 mGray. Median follow-up was 27 months, significantly longer in STD compared with vHPSD group (43 [31-68] vs. 13 [8-19], respectively; P ≤ 0.001). The recurrence rate was 33.2% and major complications 8.6%. Compared with STD, vHPSD resulted in a significantly shorter procedure duration (125 vs. 180 min, P ≤ 0.001), shorter fluoroscopy time (22.7 ± 9.5 vs. 39.2 ± 14.3 min, P ≤ 0.001), and lower fluoroscopy dose (283.8 ± 161.1 vs. 438.3 ± 216.1 mGray, P ≤ 0.001). No long-term recurrence difference was observed when the follow-up periods were comparable. No difference in complication rate was observed (8.5% vs. 8.6%, P = 0.988). CONCLUSIONS: Outcomes in AFib CA in a Latin American low-volume private center can be considered acceptable, with efficacy and safety similar to those reported in the literature. Compared with STD ablation, vHPSD showed higher efficiency with similar efficacy and safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Estudos Longitudinais , América Latina , Ablação por Cateter/métodos , Fluoroscopia , Resultado do Tratamento , Duração da Cirurgia , Fatores de Tempo
3.
Artigo em Inglês | MEDLINE | ID: mdl-37773556

RESUMO

BACKGROUND: There are multiple factors in both technique and substrate that lead to recurrence of atrial fibrillation after ablation. We sought to examine whether the degree of heart rate increase (HRI) caused by concurrent high-power-short-duration (HPSD) incidental parasympathetic denervation during AF ablation predicts long term success. Between December 2018 and December 2021, prospectively enrolled 214 patients who presented in sinus rhythm at AF ablation. Used 50 W of power and contact force (CF) of 5-15 g and 10-20 g at a flow rate of 40 mL/min on the anterior and posterior left atrial walls, respectively. RESULTS: Males were 143 (66.8%) and paroxysmal was 124 (57.9%) patients. Mean age 61.1 ± 12.3 years and follow-up time was 32.8 ± 13.2 months. Arrhythmia occurred after 90 days in 39 (18.2%) patients, 19 (48.7%) from the paroxysmal and 20 (51.3%) from the persistent AF patients. Recurrence group showed a lower HRI from a mean of 57 ± 7.7 to 64.4 ± 10.4 bpm (12.3%) while in success group HRI was from 53.8 ± 9.7 to 66.8 ± 11.6 bpm [(24.2%) p = 0.04]. We divided HRI in 3 percentiles of ≤ 8%, > 8 ≤ 37% and > 37%. A predictor of recurrence was identified in those in the first (< 8%, p = 0.006) and a predictor of success in the later (> 37%, p = 0.01) HRI percentile. CONCLUSION: Atrial fibrillation ablation with HPSD incidental cardiac parasympathetic denervation identified that patients with lower heart rate increase are prone to recurrence while those with higher heart rate increase had higher maintenance of sinus rhythm at a long-term follow-up.

4.
Heart Vessels ; 37(10): 1749-1756, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35430635

RESUMO

Different results are described after atrial fibrillation ablation and multiple predictors of recurrence are well established. Evaluate and analyze if heart rate increase (HRI) during a first atrial fibrillation (AF) ablation with low-power long-duration (LPLD) and subsequently with high-power short-duration (HPSD) can impact. Retrospectively analyzed 340 consecutive patients (pts) undergoing first AF ablation. There were 158 pts in LPLD group: 113 (71.5%) paroxysmal AF with ablation with a power of 30/20 w, on anterior and posterior left atrial (LA) wall, respectively, and contact force of 10-30g for 30 s. There were 182 pts in HPSD group: 106 (58.2%) paroxysmal AF, who underwent ablation with 45/50 w, contact force of 8-15g/10-20g and 35 mL/min flow rate on anterior and posterior left atrial wall, respectively. Median follow-up was 32 ± 16 months. Success was observed in 94 (59.5%) patients in LPLD and 152 (83.5%) in HPSD, in LPLD group we documented a median HRI of 4.3 bpm (8%), compared to preablation heart rate, while a higher HRI in HPSD group of HRI 13.5 bpm (27.2%) was noted. Heart rate increase was associated with a higher success rate in both ablation techniques and independently showed an important impact on the success rate after AF ablation. HPSD compared to LPLD showed a higher proportion of HRI and also demonstrated a superiority in maintaining sinus rhythm at a long-term follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA