Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Medicina (Kaunas) ; 60(7)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39064549

RESUMO

Gastroesophageal reflux disease (GERD) is one of the most common diseases that occurs secondary to failure of the antireflux barrier system, resulting in the frequent and abnormal reflux of gastric contents to the esophagus. GERD is diagnosed in routine clinical practice based on the classic symptoms of heartburn and regurgitation. However, a subset of patients with atypical symptoms can pose challenges in diagnosing GERD. An esophagogastroduodenoscopy (EGD) is the most common initial diagnostic test used in the assessment for GERD, although half of these patients will not have any positive endoscopic findings suggestive of GERD. The advanced endoscopic techniques have improved the diagnostic yield of GERD diagnosis and its complications, such as Barrett's esophagus and early esophageal adenocarcinoma. These newer endoscopic tools can better detect subtle irregularities in the mucosa and vascular structures. The management options for GERD include lifestyle modifications, pharmacological therapy, and endoscopic and surgical interventions. The latest addition to the armamentarium is the minimally invasive endoscopic interventions in carefully selected patients, including the electrical stimulation of the LES, Antireflux mucosectomy, Radiofrequency therapy, Transoral Incisionless Fundoplication, Endoscopic Full-Thickness plication (GERDx™), and suturing devices. With the emergence of these advanced endoscopic techniques, it is crucial to understand their selection criteria, advantages, and disadvantages.


Assuntos
Refluxo Gastroesofágico , Humanos , Refluxo Gastroesofágico/diagnóstico , Refluxo Gastroesofágico/terapia , Fundoplicatura/métodos , Endoscopia do Sistema Digestório/métodos
2.
Diagnostics (Basel) ; 14(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337785

RESUMO

Current standard methods for evaluating benign vocal lesions, including white light laryngoscopy and video laryngostroboscopy, may struggle to identify smaller lesions. While histopathological results obtained from laryngeal microsurgery provide definitive results, their invasiveness can lead to scarring and impaired phonological outcomes. Intralesional steroid injection has recently gained acceptance, but it lacks pathological diagnostic capabilities. Therefore, there is a growing need for a simple examination that can enhance the diagnosis of benign vocal lesions. NBI, from Olympus Corporation, has shown promising outcomes in detecting and characterizing laryngeal lesions. The i-scan technology by PENTAX, while providing the ability to improve visual clarity during endoscopic procedures, has been addressed less in this field. Our study aims to further investigate the application of i-scan imaging in benign vocal lesions, enrolling patients diagnosed with vocal cysts, polyps, and nodules. We conducted i-scan imaging prior to office-based intralesional steroid injection, assessing the possibility of its providing additional diagnostic information for benign vocal lesions without additional burden.

3.
Eur Arch Otorhinolaryngol ; 281(3): 1409-1416, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38147115

RESUMO

OBJECTIVE: This study evaluated vocal fold leukoplakia using i-scan combined with laryngovideostroboscopy for risk assessment prediction. METHODS: A total of 141 patients with 218 lesions were enrolled in this study. Morphological characteristics of leukoplakia, assessment of the vascular pattern using i-scan, and vocal fold vibratory function were analyzed. RESULTS: The number of patients with no, mild, moderate, severe dysplasia, and invasive carcinoma were 68, 40, 17, 46 and 47, respectively. The sensitivity of morphological characteristic, vascular pattern, vibratory function and predictive model were 77.4%, 72%, 69.9%, and 82.8%, respectively. Receiver operating characteristic curve analysis of morphological characteristic, vascular pattern, vibratory function and predictive model were 0.771, 0.824, 0.769, and 0.923, respectively. The results of logistic regression analysis showed that rough morphological types, perpendicular vascular pattern, severe decrease and absence of mucosal waves increased the risk of malignancy (OR = 5.531, 4.973, and 16.992, respectively; P < 0.001). CONCLUSIONS: I-scan combined with laryngovideostroboscopy can improve the differential diagnosis of low-risk and high-risk vocal fold leukoplakia.


Assuntos
Carcinoma , Doenças da Laringe , Humanos , Prega Vocal/patologia , Doenças da Laringe/cirurgia , Leucoplasia/diagnóstico por imagem , Leucoplasia/patologia , Carcinoma/patologia , Hiperplasia/patologia
4.
Int J Colorectal Dis ; 38(1): 240, 2023 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-37755588

RESUMO

INTRODUCTION: The incremental yield of I-Scan virtual chromoendoscopy compared to high-definition white light endoscopy (HD-WLE) in detection of colorectal adenomas has not been thoroughly elucidated. METHODS: A systematic search from inception to April 2023 was conducted to identify randomized controlled trials (RCTs) comparing I-Scan to HD-WLE for detection of adenomas. A random effects model was used to compute risk difference (RD) with corresponding 95% confidence intervals in adenoma detection rate (ADR). Influence analysis was done to assess robustness of findings. The number needed to diagnose was computed. Heterogeneity was assessed using the I2 statistic and explored further by subgroup analyses defined a priori. Certainty in effect estimates was assessed using the GRADE approach. RESULTS: We identified four studies (I-Scan n = 730, HD-WLE n = 765). I-Scan increased adenoma detection by 9% (risk difference (RD), 0.09; 0.04, 0.14; I2 02%; certainty, low). Influence analysis revealed that the gain in yield remained statistically significant with exclusion of all but one study. The number needed to capture one additional adenomatous polyp with I-Scan use was 11.2. I-Scan 1 use was associated with a statistically significant gain in ADR, whereas no significant difference in ADR was noted with I-Scan use on subgroup analysis. DISCUSSION: In conclusion, I-Scan increases the yield of adenoma detection by 9% compared to HD-WLE, with low certainty in the estimate of this effect. Data on the gain in yield of detecting large polyps, sessile serrated lesions, and on the impact of formally training endoscopists and trainees in I-Scan use and similar technology on adenoma detection rate are needed.


Assuntos
Adenoma , Neoplasias Colorretais , Pólipos , Humanos , Colonoscopia , Adenoma/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Luz
5.
Digestion ; 104(1): 42-50, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36417839

RESUMO

BACKGROUND: Mucosal healing (MH) is recognized as a therapeutic target in ulcerative colitis (UC) because of evidence that it is associated with favorable clinical outcomes. Current endoscopic assessment of MH by conventional white-light endoscopy is subject to several important clinical issues including the subjective nature of assessment, intra- and interobserver variability, and persistent microscopic inflammation, even in mucosa it was observed as quiescent on conventional endoscopy. SUMMARY: Advances in image-enhancement technologies enable the provision of high-contrast images that emphasize the mucosal structures, blood vessel patterns, and color tones of the intestinal mucosa, and recently, several image-enhanced endoscopy (IEE) techniques have become available for the assessment of MH in UC. Narrow-band imaging and dual-red imaging facilitate visualization of mucosal vascular structures, which is useful for detecting minor inflammation and predicting relapse because of the capturing of information on incomplete vascular regeneration in patients with UC. Linked-color imaging (LCI) is optimized to emphasize the redness of the mucosa and blood vessels, and is superior for depicting subtle color changes arising from mucosal inflammation. LCI could possibly be used to stratify UC patients with MH on conventional endoscopy. Autofluorescence imaging and i-scan can also depict subtle histological changes underlying the healing of mucosa in UC, revealing them as simple color changes. KEY MESSAGES: Accumulating evidence suggests that IEE techniques could overcome current unmet needs in the endoscopic assessment of MH in UC and contribute to improving therapy based on treat-to-target strategies.


Assuntos
Colite Ulcerativa , Humanos , Colite Ulcerativa/diagnóstico por imagem , Colite Ulcerativa/patologia , Endoscopia Gastrointestinal , Inflamação , Mucosa Intestinal/diagnóstico por imagem , Mucosa Intestinal/patologia , Aumento da Imagem/métodos , Índice de Gravidade de Doença , Colonoscopia/métodos
6.
J Voice ; 2022 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-35896429

RESUMO

OBJECTIVE: To explore the use of real-time virtual chromoendoscopy (i-scan) in characterizing the mucosal changes present in subjects with suspected laryngopharyngeal reflux (LPR) and to compare the inter-rater and intra-rater agreement of Reflux Finding Scores (RFS) from both laryngologists and general otolaryngologists (ORL) observing exams using both white light endoscopy (WLE) and i-scan. METHODS: This is a cross-sectional study that included 66 subjects: 46 symptomatic and 20 asymptomatic of suspected LPR based on the reflux symptom index (RSI). Subjects underwent flexible video laryngoscopic evaluation of the larynx utilising both WLE and i-scan during one continuous exam. Subjects also underwent 24-hour oropharyngeal pH-monitoring (Dx-pH). Two laryngologists and two general otolaryngologists evaluated the anonymized videos independently using RFS. Dx-pH results were interpreted using the pH graph, report and RYAN score. Subjects were then designated into one of three groups: no reflux, acid reflux and alkaline reflux. RESULTS: For the symptomatic group, no mucosal irregularities or early mucosal lesions were observed except in one subject who had granulation tissue. The mean RFS using WLE and i-scan were, respectively: 11.8 (SD 6.1) and 11.3 (SD 5.6) in symptomatic and 7.3 (SD 5.7) and 7.3 (SD 5.2) in asymptomatic group. The inter-rater agreement of RFS using WLE and i-scan for both groups were good with intraclass correlation, ICC of 0.84 and 0.88 (laryngologists); and 0.85 and 0.81 (ORL). The intra-rater agreement among all four raters were good to excellent and similar for both WLE and i-scan (ICC of 0.80 to 0.99). 47 of 66 subjects had evidence of LPR on Dx-pH results which more specifically showed 39 subjects had "acid reflux" and 8 had "alkaline reflux". Sixteen subjects demonstrated a positive RYAN score but showed none were significantly correlated with their RFS. CONCLUSIONS: This study reports the first utilization of real-time video chromoendoscopy with i-scan technology through high-definition flexible endoscopes to attempt to characterize laryngopharyngeal findings in patients suspected of having LPR. Both general otolaryngologists and laryngologists were equally capable of reliably calculating the RFS using both WLE and i-scan, however no significant improvement in agreement or change in RFS was found when i-scan technology was employed. LEVEL OF EVIDENCE: Level 2.

7.
Health Sci Rep ; 5(3): e621, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35509392

RESUMO

Background and Aim of the Work: Helicobacter pylorigastritis can cause serious adverse effects in the short and long term. I-scan optical enhancement (OE) has a potential role to distinguish areas of infected mucosa and allow for targeted biopsy. It improves visual contrast and mucosal pattern characterization. The work aims to determine if the diagnostic yield of the CLOtest could be improved by using endoscopic I-scan OE technology for targeted gastric biopsy sampling. Patients and Methods: A prospective study recruited 112 adult patients with active H. pylori infection diagnosed by C13 UBT at Nizwa General Hospital from March 2021 to January 2022. The patients underwent a careful examination by nonmagnifying upper endoscopy and I-scan OE 3 moods, then randomly allocated into two groups. Group A: nontargeted double biopsies from the antrum and mid corpus. Group B: I-scan OE-directed targeted biopsy from abnormal mucosal patterns. The biopsy specimens were inoculated into CLOtest kits; the reading time of the positive results was at 1, 4, and 24 h. Results: Group B had a 92.8% positive CLOtest compared to 89.3% in group A (p = 0.501). One-hour CLOtest was positive in 78.5% of the patients in group B compared to 60.7% in group A (p = 0.047), while group A had a significantly more positive CLOtest at 24 h. Conclusion: Sampling a targeted gastric biopsy with the aid of I-scan -OE for CLOtest significantly hastens the positive reading time with high sensitivity.

8.
Arab J Gastroenterol ; 23(2): 70-74, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35473684

RESUMO

BACKGROUND AND STUDY AIMS: This study aimed to determine whether the use of i-scan endoscopy provides additional benefits to conventional endoscopy in the diagnosis of gastric precancerous lesions. PATIENTS AND METHODS: A total of 120 patients with histologically-verified intestinal metaplasia (IM) or atrophic gastritis (AG) were prospectively evaluated by esophagogastroduodenoscopy. Endoscopic examinations were performed using i-scan and high-definition white-light endoscopy (HD-WLE). The diagnostic yields of both techniques and the number of targeted biopsies per patient were compared. RESULTS: A total of 318 suspicious lesions were detected in 108 patients with i-scan (n = 186) and 81 patients with HD-WLE (n = 132). The diagnostic yields of i-scan and HD-WLE were 81.6% (98/120) versus 77.5% (93/120), respectively (p > 0.05). When only targeted biopsies were taken into account, the diagnostic yields of i-scan and HD-WLE were 89.8% versus 65.4%, respectively (p < 0.05). The mean number of biopsies per patient for i-scan and HD-WLE were 3.27 (393/120) and 7.3 (882/120), respectively (p < 0.05). The mean endoscopic procedure times were 16 and 17 min for i-scan and HD-WLE, respectively (p > 0.05). CONCLUSIONS: Although targeted biopsies with i-scan were not found to be significantly superior to either targeted or random biopsies with HD-WLE, the number of biopsies required to confirm these lesions was much lower.


Assuntos
Gastrite Atrófica , Lesões Pré-Cancerosas , Neoplasias Gástricas , Endoscopia Gastrointestinal , Gastrite Atrófica/diagnóstico , Humanos , Metaplasia/diagnóstico por imagem , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/patologia , Neoplasias Gástricas/patologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-35243115

RESUMO

Precise endoscopic assessment is necessary to detect neoplastic changes in an early stage. Electronic or virtual chromo-endoscopy (ECE) is an alternative to conventional dye-based chromo-endoscopy which markedly improves capillary pattern and hence can detect micro-vessel morphological changes of early neoplasia to target biopsies and aid in diagnosis. The clinical significance increased after the advent of endoscopic treatment modalities like ESD/EMR which requires precise delineation of extent and depth of lesion. Most of the studies have used narrow-band imaging (NBI) (Olympus Medical Systems Tokyo, Japan), although data from i-SCAN (PENTAX Endoscopy, Tokyo, Japan) and flexible spectral imaging color enhancement (FICE) (Fujinon, Fujifilm Medical Co, Saitama, Japan) are emerging. Electronic chromo-endoscopy is convenient compared to dye-based chromo-endoscopy in the sense that it is available at the push of a button in endoscope and reduces procedure time substantially with comparable efficacy. Scope of this review is to discuss available electronic chromo-endoscopy modalities and their role in the diagnosis, surveillance, and management of early GI neoplasia.

10.
Gastrointest Endosc Clin N Am ; 31(3): 543-561, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34053638

RESUMO

This article explores advances in endoscopic neoplasia detection with supporting clinical evidence and future aims. The ability to detect early gastric neoplastic lesions amenable to curative endoscopic submucosal dissection provides the opportunity to decrease gastric cancer mortality rates. Newer imaging techniques offer enhanced views of mucosal and microvascular structures and show promise in differentiating benign from malignant lesions and improving targeted biopsies. Conventional chromoendoscopy is well studied and validated. Narrow band imaging demonstrates superiority over magnified white light. Autofluorescence imaging, i-scan, flexible spectral imaging color enhancement, and bright image enhanced endoscopy show promise but insufficient evidence to change current clinical practice.


Assuntos
Neoplasias Gástricas , Biópsia , Endoscopia , Humanos , Imagem de Banda Estreita , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia
11.
Clin Endosc ; 54(6): 881-887, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33401348

RESUMO

BACKGROUND/AIMS: To date, no reports have compared the diagnostic efficacy of narrow-band imaging (NBI) and i-scan for the histologic prediction of intermediate-to-large colorectal polyps. We aimed to compare the diagnostic accuracy of NBI and i-scan in predicting histology, and their inter-/intra-observer agreement. METHODS: We performed a prospective, randomized study that included 66 patients (NBI, n=33 vs. i-scan, n=33) with colorectal polyps (size >10 mm but <50 mm) who underwent colonoscopic resection. During the procedure, three endoscopists documented their prediction using the Japan NBI Expert Team (JNET) classification. Two months after study completion, the endoscopists reviewed still images and video clips for analysis. RESULTS: The overall diagnostic accuracies in the NBI and i-scan groups were 73.7% (73/99) and 75.8% (75/99), respectively, and there was no statistical significance between the two groups (p=0.744). The JNET classification as applied to NBI and i-scan showed substantial inter-observer agreement (NBI κ-value 0.612, p=0.001 vs. i-scan κ-value 0.662, p=0.002). Additionally, the κ-values of intra-observer agreement were in the range of 0.385-0.660 with NBI and 0.364-0.741 with i-scan. CONCLUSION: NBI and i-scan have similar diagnostic accuracies for the histologic prediction of intermediate-to-large colorectal polyps. Furthermore, the inter-/intra-observer agreement was acceptable for both modalities when the JNET classification was applied.

12.
Thyroid ; 29(11): 1523-1535, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31452449

RESUMO

Background: Studies report a wide spectrum of 124I positron emission tomography (PET)/computed tomography (CT) sensitivity and specificity in the detection of differentiated thyroid cancer (DTC) lesions. This study reviews the lesion detection rate of pretherapy 124I PET/CT in different patient populations and further analyzes the factors necessary for a better detection on 124I PET/CT. Methods: A literature search was performed using multiple different databases (MEDLINE, EMBASE, Northern Lights, and handsearching) covering 1996 to April 2018. Two reviewers reviewed and extracted study data for 124I, 123I, and 131I scans in DTC. Results: This review includes 4 retrospective and 10 prospective studies in which 495 DTC patients underwent 124I and 131I imaging; no studies made comparisons with 123I. In the reports that compared 124I PET/CT with diagnostic 131I scans, there were a total of 72 patients in whom 120 lesions were detected on 124I imaging, whereas only 52 were detected on diagnostic 131I scans. In publications that compared 124I with post-therapy 131I scans in 266 patients, 410 lesions were detected with 124I PET, whereas 390 were detected on post-therapy 131I scans. Based on 124I PET/CT in six studies, TNM staging was revised in 15-21% of patients, and disease management was altered in 5-29% of patients. Conclusions:124I PET/CT is able to identify a greater number of foci compared with diagnostic 131I scans. 124I PET may have better detection compared with post-therapy 131I scans in patients who are 131I therapy naive, have less aggressive pathology, or do not have disseminated lung metastases. Additional metastatic lesion detection by 124I PET may have a significant clinical impact in the management of patients before 131I therapy in some patients.


Assuntos
Radioisótopos do Iodo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos
13.
Therap Adv Gastroenterol ; 11: 1756284818814948, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30574190

RESUMO

OBJECTIVE: i-Scan is a digital image enhancement technology, reported to improve diagnostic performance during endoscopy. Previous studies have investigated the accuracy of i-scan for distinguishing between neoplastic and non-neoplastic colonic polyps and suggested diagnostic accuracy close to that required for use in routine clinical practice. The aim of this study was to perform a meta-analysis of the available literature investigating diagnostic accuracy for i-scan optical diagnosis when made in real time for colorectal polyps <10 mm in size. DATA SOURCES: The databases of Medline, Embase and the Cochrane Library were searched for relevant studies. METHODS: A bivariate random effects model was used to produce pooled sensitivity and specificity values, and univariable meta-regression was applied for subgroup analysis. RESULTS: The meta-analysis included 15 studies, and diagnosis of 2817 polyps. The area under the hierarchical summary receiver-operating characteristic curve was 0.96. The pooled sensitivity of i-scan optical diagnosis was 0.92 (95% confidence interval 0.85-0.95). The specificity was 0.90 (95% confidence interval 0.83-0.94). CONCLUSIONS: This meta-analysis updates and summarizes the available evidence concerning the diagnostic performance of i-scan for small colorectal polyps. An acceptable degree of accuracy was found, showing potential to support a 'resect and discard' strategy for colonic polyps. There was not found to be a significant difference in diagnostic performance between different clinical settings (i.e. teaching hospitals or general hospitals).

14.
JSLS ; 22(4)2018.
Artigo em Inglês | MEDLINE | ID: mdl-30450000

RESUMO

BACKGROUND AND OBJECTIVES: Colorectal cancer is the third leading cause of cancer-related death. Excision of premalignant polyps has a significant impact on reducing colorectal cancer mortality and morbidity. Colonoscopy is considered to be the gold standard for the diagnosis and affords an opportunity for treatment of colonic polyps. In recent years, serious debates have taken place because of the biological characteristics of diminutive polyps (DPs), polypectomy complications, and serious costs. There has not yet been a consensus on the management of DPs. The objectives of this study were to demonstrate the real clinical importance of DPs smaller than 5 mm in diameter, which are frequently seen in geriatric patients by new endoscopic techniques, and to help in determining screening and surveillance programs. METHODS: The patients who underwent colonoscopy and were found to have a diminutive colorectal polyp (<5 mm from September 1, 2016 through September 1, 2017), were classified into 3 groups according to the imaging method used: flexible spectral imaging color enhancement (FICE), narrow band imaging (NBI), or I-SCAN. In all groups, demographic data were compared according to Paris classification (morphologic) and Kudo classification (correlation between the prediction of endoscopic diagnosis and final pathological examination) in terms of sensitivity, specificity, and negative and positive predictive values. RESULTS: Two hundred sixty-seven patients were included in the study: 97 in the NBI group, 83 in the FICE group, and 87 in the I-SCAN group. There were no statistically significant differences between NBI, FICE, and I-SCAN in differentiating neoplastic and nonneoplastic polyps, according to the Kruskal-Wallis test (P = .809). CONCLUSIONS: The estimated progression rates of DPs to advanced adenomas or colorectal cancer (CRC) are very low. Missing these polyps or not excising them may lead to failure to diagnose some cancers. There is a need for further comprehensive studies of removing all polyps to determine whether non-high-risk lesions require further pathologic examination and to re-examine routine surveillance programs.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Pólipos do Colo/diagnóstico por imagem , Fatores Etários , Idoso , Neoplasias do Colo/etiologia , Pólipos do Colo/complicações , Pólipos do Colo/patologia , Colonoscopia , Feminino , Humanos , Aumento da Imagem , Masculino , Imagem de Banda Estreita , Estudos Prospectivos , Sensibilidade e Especificidade
15.
United European Gastroenterol J ; 6(5): 748-754, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30083337

RESUMO

BACKGROUND: i-Scan is an image enhancement modality, which provides enhanced views of mucosal structures and vascular patterns. METHODS: A modified Delphi process was used to develop a series of evidence-based statements on the role of high-definition white light (HDWL) and i-Scan for the detection and diagnosis of colorectal neoplasms. Each statement was voted to achieve consensus (i.e. >80% agreement). RESULTS: Seven proposed statements achieved consensus: (1) HDWL is recommended rather than standard definition (SD) for detection and diagnosis of colorectal neoplasms; (2) HDWL colonoscopy with i-Scan improves polyp and adenoma detection rates when compared with SD colonoscopy; (3) HDWL + i-Scan is superior to HDWL alone for the optical diagnosis of colorectal neoplasms; (4) HDWL + i-Scan in expert hands meets American Society for Gastrointestinal Endoscopy (ASGE) in the Preservation and Incorporation of Valuable Endoscopic Innovations (PIVI) standards for optical diagnosis of diminutive neoplasms; (5) HDWL + i-Scan in non-expert hands does not meet ASGE PIVI standards for optical diagnosis of diminutive neoplasms; (6) optical diagnosis of polyps with i-Scan has a learning curve and needs systematic training; and (7) the performance of i-Scan for the in vivo diagnosis of colorectal neoplasms is similar to Narrow Band Imaging (NBI) and Fuji Intelligent Chromo Endoscopy (FICE). CONCLUSIONS: Seven proposed statements on the use of HDWL and i-Scan for the detection and diagnosis of colorectal neoplasms achieved consensus.

16.
Comput Biol Med ; 102: 251-259, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29773226

RESUMO

BACKGROUND: In medical image data sets, the number of images is usually quite small. The small number of training samples does not allow to properly train classifiers which leads to massive overfitting to the training data. In this work, we investigate whether increasing the number of training samples by merging datasets from different imaging modalities can be effectively applied to improve predictive performance. Further, we investigate if the extracted features from the employed image representations differ between different imaging modalities and if domain adaption helps to overcome these differences. METHOD: We employ twelve feature extraction methods to differentiate between non-neoplastic and neoplastic lesions. Experiments are performed using four different classifier training strategies, each with a different combination of training data. The specifically designed setup for these experiments enables a fair comparison between the four training strategies. RESULTS: Combining high definition with high magnification training data and chromoscopic with non-chromoscopic training data partly improved the results. The usage of domain adaptation has only a small effect on the results compared to just using non-adapted training data. CONCLUSION: Merging datasets from different imaging modalities turned out to be partially beneficial for the case of combining high definition endoscopic data with high magnification endoscopic data and for combining chromoscopic with non-chromoscopic data. NBI and chromoendoscopy on the other hand are mostly too different with respect to the extracted features to combine images of these two modalities for classifier training.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Diagnóstico por Computador/métodos , Reconhecimento Automatizado de Padrão , Algoritmos , Colonoscopia , Neoplasias Colorretais/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Endoscopia , Humanos , Aumento da Imagem/métodos
17.
World J Gastroenterol ; 24(10): 1167-1180, 2018 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-29563760

RESUMO

AIM: To perform a systematic review and meta-analysis for the diagnostic accuracy of in vivo lesion characterization in colonic inflammatory bowel disease (IBD), using optical imaging techniques, including virtual chromoendoscopy (VCE), dye-based chromoendoscopy (DBC), magnification endoscopy and confocal laser endomicroscopy (CLE). METHODS: We searched Medline, Embase and the Cochrane library. We performed a bivariate meta-analysis to calculate the pooled estimate sensitivities, specificities, positive and negative likelihood ratios (+LHR, -LHR), diagnostic odds ratios (DOR), and area under the SROC curve (AUSROC) for each technology group. A subgroup analysis was performed to investigate differences in real-time non-magnified Kudo pit patterns (with VCE and DBC) and real-time CLE. RESULTS: We included 22 studies [1491 patients; 4674 polyps, of which 539 (11.5%) were neoplastic]. Real-time CLE had a pooled sensitivity of 91% (95%CI: 66%-98%), specificity of 97% (95%CI: 94%-98%), and an AUSROC of 0.98 (95%CI: 0.97-0.99). Magnification endoscopy had a pooled sensitivity of 90% (95%CI: 77%-96%) and specificity of 87% (95%CI: 81%-91%). VCE had a pooled sensitivity of 86% (95%CI: 62%-95%) and specificity of 87% (95%CI: 72%-95%). DBC had a pooled sensitivity of 67% (95%CI: 44%-84%) and specificity of 86% (95%CI: 72%-94%). CONCLUSION: Real-time CLE is a highly accurate technology for differentiating neoplastic from non-neoplastic lesions in patients with colonic IBD. However, most CLE studies were performed by single expert users within tertiary centres, potentially confounding these results.


Assuntos
Colo/diagnóstico por imagem , Colonoscopia/métodos , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Colo/patologia , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Humanos , Doenças Inflamatórias Intestinais/patologia , Sensibilidade e Especificidade
18.
Otolaryngol Head Neck Surg ; 158(4): 637-640, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29336196

RESUMO

Standard KTP laser (potassium titanyl phosphate) wavelength-specific protective eyewear often impairs visualization of tissue changes during laser treatment. This sometimes necessitates eyewear removal to evaluate tissue effects, which wastes time and poses safety concerns. The objective was to determine if "virtual" or "electronic" chromoendoscopy filters, as found on some endoscopy platforms, could alleviate the restricted visualization inherent to protective eyewear. A KTP laser was applied to porcine laryngeal tissue and recorded via video laryngoscopy with 1 optical (Olympus Narrow Band Imaging) and 8 digital (Pentax Medical I-scan) chromoendoscopy filters. Videos were viewed by 11 otolaryngologists wearing protective eyewear. Using a discrete visual analog scale, they rated each filter on its ability to improve visualization,. No filter impaired visualization; 5 of 9 improved visualization. Based on statistical significance, the number of positive responses, and the lack of negative responses, narrow band imaging and the I-scan tone enhancement filter for leukoplakia performed best. These filters could shorten procedure time and improve safety; therefore, further clinical evaluation is warranted.


Assuntos
Dispositivos de Proteção dos Olhos , Lasers de Estado Sólido/uso terapêutico , Óptica e Fotônica/instrumentação , Procedimentos Cirúrgicos Otorrinolaringológicos , Animais , Cadáver , Laringoscopia , Fotografação , Suínos , Gravação em Vídeo
19.
Indian J Endocrinol Metab ; 22(6): 740-750, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30766811

RESUMO

INTRODUCTION: Differentiated thyroid carcinoma (DTC) is the most common pathological type of thyroid carcinoma, which includes papillary and follicular subtypes. DTC is usually indolent, characterized by good prognosis, and long-term survival. Total thyroidectomy is the mainstay of treatment in DTC which is followed by diagnostic whole body 131I (WBI) scan. Like other primary malignancies of the head and neck, DTC follows a consistent pattern of spread in the cervical LNs. The central compartment, level VI and VII, is the first sentinel node followed by spread to the lateral compartments levels II-V, followed by the contralateral side. Inspite of nodal involvement, DTC usually have a favourable outcome. Presence of extrapulmonary distant metastases could predict a poor prognosis for high-dose 131I therapy. However, distant metastasis occurs often as a grave event and mortality rates vary depending on metastatic sites. AIM AND OBJECTIVES: A range of rare 131I concentrating DTC deposits in sella, orbit, choroid, skeletal muscles, liver, skin, costochondral soft tissue, pancreas and kidney, and a few benign 131I concentrating sites are being depicted. MATERIALS AND METHODS: Metastatic sites from DTC can be easily identified by performing a whole body 131I (WBI) scan along with a stimulated thyroglobulin (Tg) estimation (TSH >30 uIU/ml). Apart from thyroid and thyroid-related diseases, certain benign non-thyroidal pathologies can concentrate radioiodine (131I). From 13,000 of our patients who underwent radioiodine scan for thyroid cancer, we have selected a few cases of 131I concentrating benign and malignant lesions for illustration. RESULTS: Out of 13000 DTC patients who underwent whole body 131I scintigraphy in our department from Jan 2007 till Mar 2018, 25 patients revealed benign sites of 131I uptake. 61 % patients had residual thyroid tissue with or without associated nodal involvement. Remaining patients had distant metastases. Rare sites of functioning thyroid metastases and benign sites of I 131 uptake have been selected for illustration. CONCLUSION: Apart from the WBI (two-dimensional, planar) images, single-photon emission computed tomography-computed tomography (SPECT-CT) has been incremental in localizing benign lesions which greatly depends on their location. This pictorial review highlights the need to create an awareness to detect metastatic deposits of DTC at unexpected sites. Otherwise patients will need further investigation to rule out unsuspected sites of functioning distant metastases.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-711548

RESUMO

Objective To explore the diagnostic value of the i-Scan for detection of polypoid lesions in right hemicolon during colonoscopy. Methods A total of 200 patients who underwent colonoscopy in Beijing Shijitan Hospital from January 2015 to December 2015 were enrolled. After completion of the first colonoscopy in right hemicolon, a second withdrawal was performed, using white light mode ( white light group, n=93) and i-Scan mode ( i-scan group, n=96) to detect polypoid lesions in the proximal colon. The detection rates of polyp and adenoma were compared between the two groups. Results During the twice withdrawal, compared with white light group, more polyps and adenomas were detected in i-Scan group (1. 469 VS 1. 011, P=0. 028; 0. 979 VS 0. 624,P=0. 039). The proportion of patients with more polyps and adenomas in the i-Scan group was significantly higher than that in the white light group [ 37. 5%( 36/96) VS 22. 6% ( 21/93) , P=0. 025;24. 0% ( 23/96) VS 11. 8% ( 11/93) ,P=0. 030] . i-Scan mode detected more small polyps with diameter<5 mm [ 84. 0% ( 42/50 ) VS 58. 3% ( 14/24 ) , P=0. 016 ] . However, there were no differences between the two groups in the size, location, and morphology of the detected adenomas ( all P>0. 05) . The polyp detection rates of the i-Scan group and white light group were 61. 5% (59/96) and 48. 4% (45/93), respectively (P=0. 071), and the adenoma detection rates were 47. 9% (46/96) and 35. 5% (33/93), respectively (P=0. 083). Conclusion I-Scan mode can increase the detection rate of polyps and adenomas in right hemicolon, and improve detection of polypoid lesions and bsmall polyps in patients with multiple polyps and adenomas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA