Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 183
Filtrar
1.
Sci Rep ; 14(1): 12444, 2024 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816512

RESUMO

This preregistered ex vivo investigation examined the dentinal hybrid layer formation of a resinous infiltrant (Icon), with reference to both thickness (HLT) and homogeneity when combined with modified tunnel preparation (occlusal cavity only) and internal/external caries infiltration. The adhesives Syntac and Scotchbond MP were used as controls (Groups 1 and 3) or in combination with Icon (Groups 2 and 4). A split-tooth design using healthy third molars from 20 donors resulted in 20 prepared dentine cavities per experimental group. The cavity surfaces (n = 80) were etched (37% H3PO4), rinsed, and air-dried. Rewetting with ethanol was followed by application of the respective primers. After labeling with fluorescent dyes, either Syntac Adhesive/Heliobond or Scotchbond MP Adhesive was used alone or supplemented with Icon. HLT, as evaluated by scanning electron microscopy, did not significantly differ (P > 0.05), and confocal laser scanning microscopy revealed homogeneously mixed/polymerized resin-dentine interdiffusion zones in all groups. Icon can be successfully integrated into an ethanol-wet dentine bonding strategy, and will result in compact and homogeneous hybrid layers of comparable thickness considered equivalent to the non-Icon controls, thus allowing for preservation of the tooth's marginal ridge and interdental space in the case of internal/external infiltration of proximal caries.


Assuntos
Colagem Dentária , Esmalte Dentário , Dentina , Etanol , Humanos , Etanol/química , Colagem Dentária/métodos , Adesivos Dentinários/química , Dente Serotino , Cimentos de Resina/química , Restauração Dentária Permanente/métodos , Microscopia Confocal , Resinas Sintéticas/química , Cárie Dentária/terapia , Microscopia Eletrônica de Varredura , Resinas Compostas/química
2.
Front Psychol ; 15: 1353898, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38566949

RESUMO

Introduction: There are three main types of culture in human society, namely, individual-oriented, relationship-oriented and social-oriented cultures. In history, there are two main positions on the relationship between culture and self-construal: the cultural determinist position and the interaction position. After analyzing literature critically, we propose that the interaction position is more persuasive than the cultural determinist position. A self-construal model was constructed from an interactionist and polycultural perspective, pointing out the relationship between three cultures and self-construal. We argue that individuals interacting with cultures in the context of globalization can develop a more integrated self-construal. The present study proposes the existence of polycultural self-construal, and aimed to explore how self-construal factors relate to cultures. Methods: Three approaches-psychological tests, priming with cultural icons and content analysis-were used to explore mechanisms between cultures (individual-oriented, relationship-oriented, and social-oriented cultures) and self-construal. In Study 1, we recruited 460 undergraduate students as participants through campus advertising to complete three psychological tests, namely, the Cultural Identity Scale (CIS), the Marlowe-Crowne Social Approval Scale (MC-SDS), and the Polycultural Self-construal Scale (PSCS). In Study 2, we created icon materials that could prime the three cultures. The experimental process was divided into two stages: priming and measurement. First, 165 participants were presented with icon materials on the computer screen to activate the corresponding culture, and then they were asked to complete the PSCS. In Study 3, the experimental procedures were followed as for Study 2. Then the Ten Statements Test (TST) was used. Each of the 178 participants gave 10 different responses to the question of "Who am I?." Each participant's "I am …" narratives were qualitatively processed using content analysis. Results: The individual-oriented culture mainly affects the individuality and equality factor of self-construal. The relationship-oriented culture mainly impacts the relationality factor of self-construal, while the social-oriented culture mainly affects the collectivity and equality factors of self-construal. There were no significant differences in the effects of the three cultures on the autonomy factor of self-construal. The multi-components of the polycultural self-construal are difficult to interpret based on one culture type. All three cultures have specific and shared effects on human self-construal.

3.
Radiol Phys Technol ; 17(2): 389-395, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38466497

RESUMO

To investigate the geometric accuracy of the radiation focal point (RFP) and cone-beam computed tomography (CBCT) over long-term periods for the ICON Leksell Gamma Knife radiosurgery system. This phantom study utilized the ICON quality assurance tool plus, and the phantom was manually set on the patient position system before the implementation of treatment for patients. The deviation of the RFP position from the unit center point (UCP) and the positions of the four ball bearings (BBs) in the CBCT from the reference position were automatically analyzed. During 544 days, a total of 269 analyses were performed on different days. The mean ± standard deviation (SD) of the deviation between measured RFP and UCP was 0.01 ± 0.03, 0.01 ± 0.03, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively. The deviations with offset values after the cobalt-60 source replacement (0.00 ± 0.03, -0.01 ± 0.01, and -0.01 ± 0.01 mm in the X, Y, and Z directions, respectively) were significantly (p = 0.001) smaller than those before the replacement (0.02 ± 0.03, 0.02 ± 0.01, and -0.02 ± 0.01 mm in the X, Y, and Z directions, respectively). The overall mean ± SD of four BBs was -0.03 ± 0.03, -0.01 ± 0.05, and 0.01 ± 0.03 mm in the X, Y, and Z directions, respectively. Geometric positional accuracy was ensured to be within 0.1 mm on most days over a long-term period of more than 500 days.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Radiocirurgia , Radiocirurgia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde , Humanos , Controle de Qualidade , Fatores de Tempo
4.
Can J Anaesth ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38480633

RESUMO

PURPOSE: The difficult airway cart is essential for difficult airway management. Recognition of the importance of human factors in critical scenarios promoted the evolution of the difficult airway cart. Limitation to essential equipment, a structured layout, and proper labelling should be observed. We sought to redesign the difficult airway cart accordingly and analyze how perioperative professionals reacted to it. METHODS: We conducted a two-phase prospective qualitative improvement project involving a multidisciplinary team. In phase 1, we reconfigured our difficult airway cart, including developing icons for labelling the drawers and discussing the equipment content. In phase 2, we delivered a multidisciplinary educational program and pre- and postsession questionnaires were administered to the professionals involved and compared. RESULTS: Phase 1 of the project encompassed 21 participants. We presented the final layout and content of the difficult airway cart. In phase 2, 44 participants responded the presession questionnaires, and 30 participants answered the postsession questionnaires. The results showed that the new design and the implementation program increased the comfort level of professionals involved in a potential airway crisis (presession mean [standard deviation (SD)]: anesthesiologists, 8.0 [1.9]; anesthesia assistants/respiratory therapists [AAs/RTs], 9.3 [0.8]; operating room registered nurses [OR RNs], 6.3 [2.7]; P = 0.001; postsession: anesthesiologists, 8.5 [2.0]; AAs/RTs, 9.6 [0.5]; OR RN, 7.9 [2.0]; P = 0.10). Nevertheless, the improvement was only statistically significant among the OR RNs (presession mean [SD]: 6.3 [2.7]; postsession: 7.9 [2.0]; P = 0.01). Additionally, the program facilitated the recognition of the location of airway equipment in the airway cart (positive responses ranging from 97% to 100%). CONCLUSION: Our quality improvement project successfully designed and implemented a new visual-based difficult airway cart at our institution. We believe this report enables other institutions to reproduce our project.


RéSUMé: OBJECTIF: Le chariot d'intubation difficile est essentiel pour la prise en charge des voies aériennes difficiles. La reconnaissance de l'importance des facteurs humains dans les situations critiques a favorisé l'évolution du chariot d'intubation difficile. Il est crucial de se limiter à l'équipement essentiel tout en organisant les éléments de manière structurée et en les étiquetant adéquatement. Nous avons cherché à repenser le chariot d'intubation difficile en gardant ces éléments à l'esprit et à analyser la réaction des professionnel·les oeuvrant en périopératoire. MéTHODE: Nous avons réalisé un projet d'amélioration qualitative prospective en deux phases impliquant une équipe multidisciplinaire. Au cours de la phase 1, nous avons reconfiguré notre chariot d'intubation difficile, en développant notamment des icônes pour étiqueter les tiroirs et en discutant du contenu matériel. Au cours de la phase 2, nous avons mis en place un programme éducatif multidisciplinaire et des questionnaires ont été administrés aux professionnel·les concerné·es avant et après la session. RéSULTATS: La phase 1 du projet a réuni 21 participant·es. Nous avons présenté la disposition finale et le contenu du chariot d'intubation difficile. Au cours de la phase 2, 44 participant·es ont répondu aux questionnaires d'avant-session et 30 participant·es ont répondu aux questionnaires d'après-session. Les résultats ont montré que la nouvelle disposition avec icônes et le programme de mise en œuvre ont augmenté le niveau de confort des professionnel·les impliqué·es dans une situation critique potentielle impliquant les voies aériennes (moyenne avant la séance [écart type (ET)] : anesthésiologistes, 8,0 [1,9]; assistant·es en anesthésie/inhalothérapeutes, 9,3 [0,8]; personnel infirmier autorisé en salle d'opération (SOP), 6,3 [2,7]; P = 0,001; après la session : anesthésiologistes, 8,5 [2,0]; assistant·es en anesthésie/inhalothérapeutes, 9,6 [0,5]; personnel infirmier de SOP, 7,9 [2,0]; P = 0,10). Néanmoins, l'amélioration n'était statistiquement significative que chez le personnel infirmier autorisé de SOP (moyenne avant la session [ET] : 6,3 [2,7]; après la session : 7,9 [2,0]; P = 0,01). De plus, le programme a facilité la reconnaissance de l'emplacement de l'équipement pour les voies aériennes dans le chariot d'intubation (réponses positives allant de 97 % à 100 %). CONCLUSION: Dans le cadre de notre projet d'amélioration de la qualité, nous avons réussi à concevoir et mettre en œuvre un nouveau chariot d'intubation difficile avec icônes dans notre établissement. Nous pensons que ce compte rendu permettra à d'autres institutions de reproduire notre projet.

5.
Stereotact Funct Neurosurg ; 102(2): 65-73, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198760

RESUMO

INTRODUCTION: It is a normal procedure to avoid the application of ionizing radiation during pregnancy. In very rare occasions, treatment can be performed, but doses to the fetus must be evaluated and reported, and the patient must sign informed consent. There can occur two types of damage caused by ionizing radiation - deterministic and stochastic effects. Deterministic effects may occur after reaching a certain threshold (100 mGy for this study); meanwhile, stochastic effects have no limit and their probability rises with dose. This study focuses on deterministic effects. CASE PRESENTATIONS: This study compares the dose measured on phantom for the area of the pelvis and the dose measured on 3 patients with dosimeters positioned on the pelvis irradiated on Leksell Gamma Knife Perfexion/Icon. The mean dose for measurement on phantom for the pelvis was 0.73 ± 0.76 mGy, and for the patients, it was 1.28 mGy, 0.493 mGy, and 0.549 mGy which is 80 times lower, 200 times lower, and 180 times lower than the threshold for deterministic effects, respectively. CONCLUSION: The measurement carried on phantom served as the base for drafting informed consent and provided initial proof that treatment can be safely delivered. Measurements performed on patients only confirmed that irradiation of pregnant patients on Leksell Gamma Knife Perfexion/Icon is safe relative to the deterministic effects. Nevertheless, pregnant patients should be treated with ionizing radiation only in very extraordinary situations.


Assuntos
Radiocirurgia , Humanos , Gravidez , Feminino , Radiocirurgia/métodos , Imagens de Fantasmas
6.
Eur Arch Paediatr Dent ; 25(1): 105-116, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38285169

RESUMO

PURPOSE: To compare the aesthetic improvement of Molar-Incisor-Hypomineralisation (MIH) opacities treated by applying Icon-Etch for three cycles with the opacities treated by Icon-Etch for once, in the course of resin infiltration technique. METHODS: Thirty incisors were sorted based on the colour of the opacities and then distributed according to the number of Icon-Etch cycles using a randomisation table into the groups: (1) White/Creamy one cycle, (2) White/Creamy three cycles, (3) Yellow/Brown one cycle, (4) Yellow/Brown three cycles. The primary outcomes of applying the resin infiltration to the opacities were compared amongst groups according to the parents' satisfaction, the amount of coverage, and the colour matching with the surrounding sound enamel. The stability of the results after 3 months was evaluated using a spectrophotometer. RESULTS: The colour of the opacity pre-treatment affected the outcomes significantly (p < 0.05), compared according to the method of application (p > 0.05) in terms of parents' satisfaction. Whilst the multiple applications for Icon-Etch cycles showed more coverage amount in White/Creamy opacities than the application ones (p < 0.05); in colour matching, there was no statistically significant difference between the two methods (p > 0.05). For yellow/brown opacities, some negative results occurred with the single Icon-Etch cycle. CONCLUSION: In MIH opacities, it is possible to rely on the resin infiltration as a minimally invasive method to achieve acceptable results, especially with multiple Icon-Etch cycles applications in the white/creamy opacities. The colour stability has not been affected by either the colour of the opacity or the number of cycles.


Assuntos
Hipoplasia do Esmalte Dentário , Humanos , Hipoplasia do Esmalte Dentário/terapia , Incisivo , Projetos Piloto , Dente Molar , Prevalência
7.
Ergonomics ; 67(3): 433-445, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37376815

RESUMO

Visual design form is an important factor affecting users' cognition of icons, which plays an important role in visual search and the perception of the status shown by icons. In the graphical user interface, the icon colour is regularly used to indicate the running state of a function. The aim of this study was to investigate the effects of icon colour features on user perception and visual search performance under different background colours. There were three independent variables in the study, including background colour (white and black), icon polarity (positive and negative), and icon saturation (60, 80, and 100%). Thirty-one participants were recruited for the experiment. Task performance and eye movement results indicated that white background as well as positive polarity and 80% saturation icons brought the best performances. The findings of this study provide useful guidelines for designing more efficient and user-friendly icons and interfaces in the future.Practitioner summary: This study was to investigate the effects of icon colour features (polarity and saturation) on user perception and visual search performance under different colour backgrounds. Task performance and eye movement results indicated that white background as well as positive polarity and 80% saturation icons brought the best performances.


Assuntos
Cognição , Movimentos Oculares , Humanos , Cor , Reconhecimento Psicológico
8.
Lab Invest ; 104(4): 100321, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38154497

RESUMO

With more novel drugs being approved for the treatment of ovarian carcinoma, the question remains to what extent patients benefit from antiangiogenic treatment with bevacizumab, either in combination with poly-(ADP-ribose) polymerase inhibitors or as single-agent maintenance. As fibroblast growth factor receptors and their ligands (FGFRs/FGFs) are key players in angiogenic signaling and have been linked to resistance to several drugs, we investigated the prognostic or predictive potential of FGFs/FGFRs signaling in the context of bevacizumab treatment within the prospective phase III AGO-OVAR11/ICON-7 study. FGFR1, FGFR2, FGFR3, FGFR4, FGF1, and FGF19 gene expressions were determined in 380 ovarian carcinoma tumor samples collected from German centers in the multicenter phase III AGO-OVAR11 trial/ICON-7 trial. All patients received carboplatin and paclitaxel, administered every 3 weeks for 6 cycles, and were randomized to bevacizumab. Expressions of FGFR1, FGFR2, FGF1, and FGF19 were associated with progression-free survival in both uni- and multivariate (FGFR1: HR, 1.6, P < .001; FGFR2: HR, 1.6, P = .002; FGF1: HR, 2.3, P < .001; and FGF19: HR, 0.7; P = .007) analysis. A signature built by FGFR1, FGFR4, and FGF19 defined a subgroup (n = 62) of patients that derived the greatest bevacizumab-associated improvement of progression-free survival (HR, 0.3; P = .004). In this exploratory analysis of a prospective randomized phase III trial, we provide evidence that the expression of FGFRs/FGFs might have independent prognostic values. An FGFR/FGF-based gene signature identified in our study appears to predict long-term benefit from bevacizumab. This observation is hypothesis-generating and requires validation on independent cohorts.


Assuntos
Carcinoma , Neoplasias Ovarianas , Humanos , Feminino , Bevacizumab/farmacologia , Bevacizumab/uso terapêutico , Fator 1 de Crescimento de Fibroblastos , Estudos Prospectivos , Fatores de Crescimento de Fibroblastos , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/genética
9.
J Clin Med ; 12(21)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37959211

RESUMO

The primary aim of this study was to assess the medium-term outcomes of the Global Icon stemless shoulder replacement in patients who have undergone primary total shoulder arthroplasty (TSA) for glenohumeral joint osteoarthritis. A retrospective review of patients who had undergone a TSA using the Global Icon stemless shoulder system was performed. The Western Ontario Osteoarthritis Shoulder (WOOS) Index and Oxford Shoulder Score (OSS) were evaluated pre-operatively and at 12 to 24 months post-operatively. Radiological outcomes, operation time, and post-operative complications were reported. Primary analysis for the WOOS Index and OSS focused on detecting within-group treatment effects at 24 months using a repeated measures ANOVA. Thirty patients were included in the study. Post-surgery, there was a significant improvement at 24 months on the OSS (ES = 0.932, CI: 41.7 to 47.7, p < 0.001) and the WOOS Index (ES = 0.906, CI: 71.9 to 99.8, p < 0.001). Radiographs revealed that no component loosened, migrated, or subsided. The median operative time was 75.5 (IQR: 12.25, range: 18 to 105) min. No implant-related complications were reported. The Global Icon stemless replacements have excellent clinical outcomes in this cohort at 12- and 24-month follow-up with no implant-related complications.

10.
Med Decis Making ; 43(7-8): 774-788, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37872798

RESUMO

OBJECTIVE: People differ in whether they understand graphical or numerical representations of statistical information better. However, assessing these skills is often not feasible when deciding which representation to select or use. This study investigates whether people choose the representation they understand better, whether this choice can improve risk comprehension, and whether results are influenced by participants' skills (graph literacy and numeracy). METHODS: In an experiment, 160 participants received information about the benefits and side effects of painkillers using either a numerical or a graphical representation. In the "no choice" condition, the representation was randomly assigned to each participant. In the "choice" condition, participants could select the representation they would like to receive. The study assessed gist and verbatim knowledge (immediate comprehension and recall), accessibility of the information, attractiveness of the representation, as well as graph literacy and numeracy. RESULTS: In the "choice" condition, most (62.5%) chose the graphical format, yet there was no difference in graph literacy or numeracy (nor age or gender) between people who chose the graphical or the numerical format. Whereas choice slightly increased verbatim knowledge, it did not improve gist or overall knowledge compared with random assignment. However, participants who chose a representation rated the representation as more attractive, and those who chose graphs rated them as more accessible than those without a choice. LIMITATIONS: The sample consisted of highly educated undergraduate students with higher graph literacy than the general population. The task was inconsequential for participants in terms of their health. CONCLUSIONS: When people can choose between representations, they fail to identify what they comprehend better but largely base that choice on how attractive the representation is for them. HIGHLIGHTS: People differ systematically in whether they understand graphical or numerical representations of statistical information better. However, assessing these underlying skills to get the right representation to the right people is not feasible in practice. A simple and efficient method to achieve this could be to let people choose among representations themselves.However, our study showed that allowing participants to choose a representation (numerical v. graphical) did not improve overall or gist knowledge compared with determining the representation randomly, even though it did slightly improve verbatim knowledge.Rather, participants largely chose the representation they found more attractive. Most preferred the graphical representation, including those with low graph literacy.It would therefore be important to develop graphical representations that are not only attractive but also comprehensible even for people with low graph literacy.


Assuntos
Compreensão , Estatística como Assunto , Humanos , Rememoração Mental
11.
J Orthod Sci ; 12: 43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37881679

RESUMO

OBJECTIVES: In order to assess the changes in tooth orthodontic adhesive interface microleakage after applying a caries resin penetrated to the sound enamel tooth surface in different storage media. MATERIALS AND METHODS: A total of 60 human maxillary first premolars (orthodontic extraction) were collected by random separation of the teeth into two equal groups. The control group was classified into three subgroups (n = 10) (control in deionized water, control in milk, and control in energy drink), while the experimental one (treated with ICON) was categorized into three subgroups (n = 10) (ICON in deionized water, ICON in milk, and ICON in energy drink) incubation phase lasted three weeks in total. RESULTS: A one-way analysis of variance (ANOVA) yielded a significant difference between all experimental subgroups (ICON in deionized water, ICON in milk, and ICON in energy drink) and control subgroups (control in deionized water, control in milk, and control in energy drink). The control group in the energy drink subgroup had the highest mean microleakage value when compared to the other subgroups, whereas the resin-infiltrated group in deionized water had the lowest mean value. According to the results of the T-test, ICON pre-treatment tooth samples had significantly lower mean values of microleakage than non-ICON tooth samples. CONCLUSIONS: The adhesive system (control group) revealed that a resin infiltrate on a sound enamel surface prior to orthodontic bracket bonding reduced bracket tooth interface microleakage in all examined samples. The ICON-infiltrated surface was discovered to provide a secondary preventive strategy against white spot lesion development by reducing microleakage under brackets.

12.
Med Decis Making ; 43(7-8): 803-820, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37842816

RESUMO

BACKGROUND: Graphical representation formats (e.g., icon arrays) have been shown to lead to better understanding of the benefits and risks of treatments compared to numbers. We investigate the cognitive processes underlying the effects of format on understanding: how much cognitive effort is required to process numerical and graphical representations, how people process inconsistent representations, and how numeracy and graph literacy affect information processing. METHODS: In a preregistered between-participants experiment, 665 participants answered questions about the relative frequencies of benefits and side effects of 6 medications. First, we manipulated whether the medical information was represented numerically, graphically (as icon arrays), or inconsistently (numerically for 3 medications and graphically for the other 3). Second, to examine cognitive effort, we manipulated whether there was time pressure or not. In an additional intervention condition, participants translated graphical information into numerical information before answering questions. We also assessed numeracy and graph literacy. RESULTS: Processing icon arrays was more strongly affected by time pressure than processing numbers, suggesting that graphical formats required more cognitive effort. Understanding was lower when information was represented inconsistently (v. consistently) but not if there was a preceding intervention. Decisions based on inconsistent representations were biased toward graphically represented options. People with higher numeracy processed quantitative information more efficiently than people with lower numeracy did. Graph literacy was not related to processing efficiency. LIMITATIONS: Our study was conducted with a nonpatient sample, and the medical information was hypothetical. CONCLUSIONS: Although graphical (v. numerical) formats have previously been found to lead to better understanding, they may require more cognitive effort. Therefore, the goal of risk communication may play an important role when choosing how to communicate medical information. HIGHLIGHTS: This article investigates the cognitive processes underlying the effects of representation format on the understanding of statistical information and individual differences therein.Processing icon arrays required more cognitive effort than processing numbers did.When information was represented inconsistently (i.e., partly numerically and partly graphically), understanding was lower than with consistent representation, and decisions were biased toward the graphically represented options.People with higher numeracy processed quantitative information more efficiently than people with lower numeracy did.


Assuntos
Comunicação , Individualidade , Humanos , Cognição
13.
Front Psychol ; 14: 1149381, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37575437

RESUMO

This article lays out the foundation of a new language for easier written communication that is inherently reader-friendly and inherently international. Words usually consist of strings of sounds or squiggles whose meanings are merely a convention. In Icono, instead, they typically are strings of icons that illustrate what they stand for. "Train," for example, is expressed with the icon of a train, "future" with the icon of a clock surrounded by a clockwise arrow, and "mammal" with the icons of a cow and a mouse-their combination's meaning given by what they have in common. Moreover, Icono reveals sentence structure graphically before, rather than linguistically after, one begins reading. On smartphones and computers, writing icons can now be faster than writing alphabetic words. And using simple pictures as words helps those who struggle with conditions like dyslexia, aphasia, cerebral palsy, and autism with speech impairment. Because learning its pronunciation or phonetic spelling is optional rather than a prerequisite, and because it shows what it says, Icono is bound to be easier to learn to read-and then easier to read-than any other language, including our own.

14.
J Appl Clin Med Phys ; 24(11): e14088, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37415385

RESUMO

PURPOSE: The purpose of this study is to investigate inter-planner plan quality variability using a manual forward planning (MFP)- or fast inverse planning (FIP, Lightning)-approach for single brain lesions treated with the Gamma Knife® (GK) Icon™. METHODS: Thirty patients who were previously treated with GK stereotactic radiosurgery or radiotherapy were selected and divided into three groups (post-operative resection cavity, intact brain metastasis, and vestibular schwannoma [10 patients per group]). Clinical plans for the 30 patients were generated by multiple planners using FIP only (1), a combination of FIP and MFP (12), and MFP only (17). Three planners (Senior, Junior, and Novice) with varying experience levels re-planned the 30 patients using MFP and FIP (two plans per patient) with planning time limit of 60 min. Statistical analysis was performed to compare plan quality metrics (Paddick conformity index, gradient index, number of shots, prescription isodose line, target coverage, beam-on-time (BOT), and organs-at-risk doses) of MFP or FIP plans among three planners and to compare plan quality metrics between each planner's MFP/FIP plans and clinical plans. Variability in FIP parameter settings (BOT, low dose, and target max dose) and in planning time among the planners was also evaluated. RESULTS: Variations in plan quality metrics of FIP plans among three planners were smaller than those of MFP plans for all three groups. Junior's MFP plans were the most comparable to the clinical plans, whereas Senior's and Novice's MFP plans were superior and inferior, respectively. All three planners' FIP plans were comparable or superior to the clinical plans. Differences in FIP parameter settings among the planners were observed. Planning time was shorter and variations in planning time among the planners were smaller for FIP plans in all three groups. CONCLUSIONS: The FIP approach is less planner dependent and more time-honored than the MFP approach.


Assuntos
Neoplasias Encefálicas , Raio , Radiocirurgia , Humanos , Planejamento da Radioterapia Assistida por Computador , Dosagem Radioterapêutica , Neoplasias Encefálicas/secundário , Encéfalo
15.
Surg Neurol Int ; 14: 188, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37404506

RESUMO

Background: This study evaluates an alternative to the classical method of head fixation during Gamma Knife radiosurgery using a Leksell head frame. In the Gamma Knife® Icon™ model, a new method of head fixation is used by utilizing a thermal molded polymer mask that takes the shape of the patient's head before fixing the head to the table. However, this mask is for single use and quite expensive. Methods: We describe a new, very economical method to fix the head of the patient during radiosurgery. We used commercial, quite cheap material [polylactic acid (PLA)] plastic and made a 3D printing model for the patient's face, taking special measurements to put this mask and fix it on the Gamma Knife. The actual material cost is only $4 (100 times less than the original mask cost). Results: The new mask efficiency was tested using the movement checker software, the same one used to measure the efficiency of the original mask. Conclusion: The newly designed and manufactured mask is quite effective for use with the Gamma Knife® Icon™, with a much lower cost, and it can be manufactured locally.

16.
FASEB J ; 37(7): e23052, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37352114

RESUMO

The ion channels in sperm tail play an important role in triggering key physiological reactions, e.g., progressive motility, hyperactivation, required for successful fertilization. Among them, CatSper and KSper have been shown to be important ion channels for the transport of Ca2+ and K+ . Moreover, the voltage-gated proton channel Hv1, the sperm-specific sodium-hydrogen exchanger (sNHE), the epithelial sodium channel (ENaC), members of the temperature-sensitive TRP channel family, and the cystic fibrosis transmembrane regulator (CFTR) are also found in the flagellum. This review focuses on the latest advances in ion channels located at the flagellum, describes how they affect sperm physiological function, and summarizes some primary mutual regulation mechanism between ion channels, including PH, membrane potential, and cAMP. These ion channels may be promising targets for clinical application in infertility.


Assuntos
Canais de Cálcio , Cauda do Espermatozoide , Humanos , Masculino , Cauda do Espermatozoide/metabolismo , Canais de Cálcio/metabolismo , Sêmen/metabolismo , Espermatozoides/metabolismo , Transporte de Íons , Motilidade dos Espermatozoides/fisiologia
17.
Space Sci Rev ; 219(3): 27, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37038438

RESUMO

The design, principles of operation, calibration, and data analysis approaches of the Michelson Interferometer for Global High-resolution Thermospheric Imaging (MIGHTI) on the NASA Ionospheric Connection (ICON) satellite have been documented prior to the ICON launch. Here we update and expand on the MIGHTI wind data analysis and discuss the on-orbit instrument performance. In particular, we show typical raw data and we describe key processing steps, including the correction of a "signal-intensity dependent phase shift," which is necessitated by unexpected detector behavior. We describe a new zero-wind calibration approach that is preferred over the originally planned approach due to its higher precision. Similar to the original approach, the new approach is independent of any a priori data. A detailed update on the wind uncertainties is provided and compared to the mission requirements, showing that MIGHTI has met the ICON mission requirements. While MIGHTI observations are not required to produce absolute airglow brightness profiles, we describe a relative brightness profile product, which is included in the published data. We briefly review the spatial resolution of the MIGHTI wind data in addition to the data coverage and data gaps that occurred during the nominal mission. Finally, we include comparisons of the MIGHTI wind data with ground-based Fabry-Perot interferometer observations and meteor radar observations, updating previous studies with more recent data, again showing good agreement. The data processing steps covered in this work and all the derived wind data correspond to the MIGHTI data release Version 5 (v05).

18.
Wiad Lek ; 76(3): 575-580, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37057782

RESUMO

OBJECTIVE: The aim: To substantiate the need for a combination of interdisciplinary approaches to diagnosis, treatment and correction of dento-maxillofacial anomalies of teenagers based on the analysis of the need for orthodontic treatment using the DAI, IOTN, ICON aesthetic indices. PATIENTS AND METHODS: Materials and methods: Empirical, epidemiological, clinical, analytical-synthetic, sociological, psychological research methods, questionnaires, dental indexeshave been used in various combinations. RESULTS: Results: As a result of a clinical examination of 2,260 teenagers (1,096 boys and 1,124 girls), 1,474 individuals have been bselected for orthodontic treatment with the following degree of complexity: mild - in 25 examined (35.71±4.95%), moderate - in 31 individuals (44.28± 5.48%), heavy - 14 (20.00±3.11%). After an in-depth dental examination and determination of the psychological profile, 70 teenagers have been selected for treatment. CONCLUSION: Conclusions: The effectiveness of the use of dental indices as a screening tool to eliminate the discrepancy between objective medical indicators of the level of need for correction of dento-maxillofacial anomalies and the level of expected results in adolescents has been proven.


Assuntos
Má Oclusão , Masculino , Feminino , Humanos , Adolescente , Má Oclusão/diagnóstico , Má Oclusão/terapia , Ortodontia Corretiva , Estética Dentária
19.
Space Sci Rev ; 219(3): 23, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37007704

RESUMO

The NASA Ionospheric Connection Explorer (ICON) was launched in October 2019 and has been observing the upper atmosphere and ionosphere to understand the sources of their strong variability, to understand the energy and momentum transfer, and to determine how the solar wind and magnetospheric effects modify the internally-driven atmosphere-space system. The Far Ultraviolet Instrument (FUV) supports these goals by observing the ultraviolet airglow in day and night, determining the atmospheric and ionospheric composition and density distribution. Based on the combination of ground calibration and flight data, this paper describes how major instrument parameters have been verified or refined since launch, how science data are collected, and how the instrument has performed over the first 3 years of the science mission. It also provides a brief summary of science results obtained so far.

20.
Neurol India ; 71(Supplement): S68-S73, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37026336

RESUMO

Gamma knife radiosurgery saw the light of the day when the Swedish physician "Lars Leksell" postulated the salient first principles of stereotactic radiosurgery. Prior to being realized in its new 'avatar' "The ICON", Leksell Gamma Knife (LGK) "Perfexion" has been the most practiced model and is still in practice in most of the centers in India. The Gamma Knife ICON (the sixth generation model) utilizes the concept of the Cone-Beam Computed Tomography (CBCT) module, thus allowing non-invasive immobilization of the skull employing frameless treatments without jeopardizing accuracy to sub-millimeters. The LGK ICON however has the same stereotactic delivery and patient positioning system as Perfexion and mesmerizes the care givers with the added technically sound feature of the CBCT imaging arm, that is, CBCT and an intra-fraction motion management system. The experience with ICON on both the sub-sets of patients has been intriguing and awe-inspiring. Despite its challenges of being detected with significant intra-fraction errors, we realized that the non-invasive thermoplastic mask fixation system has its own set of specific characteristics: fairly simple dosimetry; short radiation delivery times; and calm, composed, co-operative patients. We have been successful in conducting frameless gamma knife surgeries in ~25% of patients planned for gamma knife surgery. We look forward to witness this avant-garde pioneering scientific automation being practiced in a higher number of patients.


Assuntos
Radiocirurgia , Humanos , Radiocirurgia/métodos , Imageamento Tridimensional , Cabeça , Crânio , Tomografia Computadorizada de Feixe Cônico/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...