Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1303: 342523, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38609265

RESUMO

BACKGROUND: l-lactate detection is important for not only assessing exercise intensity, optimizing training regimens, and identifying the lactate threshold in athletes, but also for diagnosing conditions like L-lactateosis, monitoring tissue hypoxia, and guiding critical care decisions. Moreover, l-lactate has been utilized as a biomarker to represent the state of human health. However, the sensitivity of the present l-lactate detection technique is inadequate. RESULTS: Here, we reported a sensitive ratiometric fluorescent probe for l-lactate detection based on platinum octaethylporphyrin (PtOEP) doped semiconducting polymer dots (Pdots-Pt) with enzymatic cascade reaction. With the help of an enzyme cascade reaction, the l-lactate was continuously oxidized to pyruvic and then reduced back to l-lactate for the next cycle. During this process, oxygen and NADH were continuously consumed, which increased the red fluorescence of Pdots-Pt that responded to the changes of oxygen concentration and decreased the blue fluorescence of NADH at the same time. By comparing the fluorescence intensities at these two different wavelengths, the concentration of l-lactate was accurately measured. With the optimal conditions, the probes showed two linear detection ranges from 0.5 nM to 5.0 µM and 5.0 µM-50.0 µM for l-lactate detection. The limit of detection was calculated to be 0.18 nM by 3σ/slope method. Finally, the method shows good detection performance of l-lactate in both bovine serum and artificial serum samples, indicating its potential usage for the selective analysis of l-lactate for health monitoring and disease diagnosis. SIGNIFICANCE: The successful application of the sensing system in the complex biological sample (bovine serum and artificial serum samples) demonstrated that this method could be used for sensitive l-lactate detection in practical clinical applications. This detection system provided an extremely low detection limit, which was several orders of magnitude lower than methods proposed in other literatures.


Assuntos
Ácido Láctico , NAD , Humanos , Atletas , Compostos Orgânicos , Oxigênio , Polímeros
2.
ACS Appl Mater Interfaces ; 9(44): 38153-38158, 2017 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-29048871

RESUMO

l-Lactate is a vital biomarker for many diseases and physiological fatigue. An AIE-active fluorophore (TPE-HPro) is combined with l-lactate oxidase (LOx) to determine l-lactate in aqueous fluid. The assay shows excellent sensitivity and anti-interference performance with a limit of detection (LOD) of 5.5 µM. In addition, sensitive detection of l-lactate is achieved even in a protein-rich environment. It is proposed that quantification of l-lactate be performed at 20 or 60 min in the current method. These characteristics endow the fluorometric assay with great potential for biomedical diagnostics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA