Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
2.
Brachytherapy ; 23(4): 433-442, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38724315

RESUMO

PURPOSES: In this study we aim to quantitatively evaluate the stability of implanted seeds in permanent breast seed implant (PBSI) brachytherapy and assess any impact on treatment quality. METHODS AND MATERIALS: Sixty-seven consecutive patients who received PBSI treatment at BC Cancer Kelowna from 2013 to 2021 with post-implant CT images available were included in this study. For each patient, two sets of post-implant CT scans were retrospectively analyzed: Day0, obtained immediately after implant, and Day30, obtained approximately one month following implant. Seed distributions were quantified using the 90% isodose contour, outlier seed maximum spread, and number of seeds located in the seroma as well as seroma quadrants. These were then compared between Day0 and Day30. Post-implant dosimetry of target volumes as well as critical structures were compared. RESULTS: The 90% isodose volume was found to decrease over time. All seeds remained in the breast region however the maximum spread of seeds increased in all directions from Day0 to Day30. All recorded target volume dosimetric parameters were, on average, lower on Day30 compared to Day0 but mean dosimetry levels still met clinical goals. Dose in critical structures was overall similar. CONCLUSIONS: In this study, we quantitatively described the changes in seed distributions as well as dosimetry from Day0 to Day30 post PBSI procedure. We addressed concerns related to seed stability in breast tissue and provided clinical evidence on dosimetric efficacy of the PBSI technique.


Assuntos
Braquiterapia , Neoplasias da Mama , Dosagem Radioterapêutica , Humanos , Braquiterapia/métodos , Braquiterapia/instrumentação , Feminino , Neoplasias da Mama/radioterapia , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Implantes de Mama , Tomografia Computadorizada por Raios X , Adulto
3.
Small ; : e2400638, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38804126

RESUMO

The lithium deposited via the complex electrochemical heterogeneous lithium deposition reaction (LDR) process on a lithium foil-based anode (LFA) forms a high-aspect-ratio shape whenever the reaction kinetics reach its limit, threatening battery safety. Thereby, a research strategy that boosts the LDR kinetics is needed to construct a high-power and safe lithium metal anode. In this study, the kinetic limitations of the LDR process on LFA are elucidated through operando and ex situ observations using in-depth electrochemical analyses. In addition, ultra-thin (≈0.5 µm) and high modulus (≥19 GPa) double-walled carbon nanotube (DWNT) membranes with different surface properties are designed to catalyze high-safety LDRs. The oxygen-functionalized DWNT membranes introduced on the LFA top surface simultaneously induce multitudinous lithium nuclei, leading to film-like lithium deposition even at a high current density of 20 mA cm-2. More importantly, the layer-by-layer assembly of the oxygen-functionalized and pristine DWNT membranes results in different surface energies between the top and bottom surfaces, enabling selective surface LDRs underneath the high-modulus bilayer membranes. The protective LDR on the bilayer-covered LFA guarantees an invulnerable cycling process in large-area pouch cells at high current densities for more than 1000 cycles, demonstrating the practicability of LFA in a conventional liquid electrolyte system.

4.
J Imaging ; 10(4)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38667990

RESUMO

This study considers a method for reconstructing a high dynamic range (HDR) original image from a single saturated low dynamic range (LDR) image of metallic objects. A deep neural network approach was adopted for the direct mapping of an 8-bit LDR image to HDR. An HDR image database was first constructed using a large number of various metallic objects with different shapes. Each captured HDR image was clipped to create a set of 8-bit LDR images. All pairs of HDR and LDR images were used to train and test the network. Subsequently, a convolutional neural network (CNN) was designed in the form of a deep U-Net-like architecture. The network consisted of an encoder, a decoder, and a skip connection to maintain high image resolution. The CNN algorithm was constructed using the learning functions in MATLAB. The entire network consisted of 32 layers and 85,900 learnable parameters. The performance of the proposed method was examined in experiments using a test image set. The proposed method was also compared with other methods and confirmed to be significantly superior in terms of reconstruction accuracy, histogram fitting, and psychological evaluation.

5.
Strahlenther Onkol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488901

RESUMO

BACKGROUND AND PURPOSE: Comparing oncological outcomes and toxicity after primary treatment of localized prostate cancer using HDR- or LDR-mono-brachytherapy (BT), or conventionally (CF) or moderately hypofractionated (HF) external beam radiotherapy. MATERIALS AND METHODS: Retrospectively, patients with low- (LR) or favorable intermediate-risk (IR) prostate cancer treated between 03/2000 and 09/2022 in two centers were included. Treatment was performed using either CF with total doses between 74 and 78 Gy, HF with 2.4-2.6 Gy per fraction in 30 fractions, or LDR- or HDR-BT. Biochemical control (BC) according to the Phoenix criteria, and late gastrointestinal (GI), and genitourinary (GU) toxicity according to RTOG/EORTC criteria were assessed. RESULTS: We identified 1293 patients, 697 with LR and 596 with IR prostate cancer. Of these, 470, 182, 480, and 161 were treated with CF, HF, LDR-BT, and HDR-BT, respectively. For BC, we did not find a significant difference between treatments in LR and IR (p = 0.31 and 0.72). The 5­year BC for LR was between 93 and 95% for all treatment types. For IR, BC was between 88% in the CF and 94% in the HF group. For CF and HF, maximum GI and GU toxicity grade ≥ 2 was between 22 and 27%. For LDR-BT, we observed 67% grade ≥ 2 GU toxicity. Maximum GI grade ≥ 2 toxicity was 9%. For HDR-BT, we observed 1% GI grade ≥ 2 toxicity and 19% GU grade ≥ 2 toxicity. CONCLUSION: All types of therapy were effective and well received. HDR-BT caused the least late toxicities, especially GI.

6.
Cancers (Basel) ; 16(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38473430

RESUMO

What treatment options are there for patients having uveal melanoma? A randomized, prospective, multi-institutional clinical trial (COMS) showed no difference in survival between brachytherapy and enucleation for medium-sized lesions. With the obvious benefit of retaining the eye, brachytherapy has flourished and many different approaches have been developed such as low-dose-rate sources using alternate low-energy photon-emitting radionuclides, different plaque designs and seed-loading techniques, high-dose-rate brachytherapy sources and applicators, and low- and high-dose-rate beta-emitting sources and applicators. There also have been developments of other radiation modalities like external-beam radiotherapy using linear accelerators with high-energy photons, particle accelerators for protons, and gamma stereotactic radiosurgery. This article examines the dosimetric properties, targeting capabilities, and outcomes of these approaches. The several modalities examined herein have differing attributes and it may be that no single approach would be considered optimal for all patients and all lesion characteristics.

7.
Brachytherapy ; 23(3): 329-334, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38538414

RESUMO

OBJECTIVES: To compare survival of patients who received LDR prostate brachytherapy relative to that of peers in the general population of England, UK. PATIENTS AND METHODS: Net survival was estimated for 2472 cases treated between 2002 and 2016 using population-based analysis guidelines. Life tables adjusted for social deprivation in England from the Office for National Statistics were used to match patients by affluence based on their postcode. RESULTS: The median (range) age at time of brachytherapy was 66 (55-84) years, 84% resided in Southeast England, 51% under an index of deprivation quintile 5 (most affluent), 55% were clinical stage T1 and the remainder T2. Death from any cause occurred in 270 patients at a median (range) of 7 (1-17) years postimplant. Five and 10-year estimates (95% CI) of overall survival were 96% (95-97) and 90% (89-92), and net survival 103% (102-104) and 109% (107-110) respectively. The net survival remained above 100% in all age-at-treatment and clinical stage groups. CONCLUSION: Net survival above 100% indicates patients survive longer than the matched general population. The study shows for the first time the net survival of patients treated with a radical therapy for localized prostate cancer in England. The impact of treatment choice on the long-term net survival advantage requires further investigation.


Assuntos
Braquiterapia , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/mortalidade , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Inglaterra/epidemiologia , Taxa de Sobrevida , Estadiamento de Neoplasias , Dosagem Radioterapêutica
8.
Sensors (Basel) ; 24(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38339627

RESUMO

Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community's need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.


Assuntos
Braquiterapia , Humanos , Braquiterapia/métodos , Dosagem Radioterapêutica , Dosímetros de Radiação , Radiometria/métodos , Software
9.
Sci Total Environ ; 917: 170178, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38280586

RESUMO

The health impacts of low-dose ionizing radiation exposures have been a subject of debate over the last three to four decades. While there has been enough evidence of "no adverse observable" health effects at low doses and low dose rates, the hypothesis of "Linear No Threshold" continues to rule and govern the principles of radiation protection and the formulation of regulations and public policies. In adopting this conservative approach, the role of the biological processes underway in the human body is kept at abeyance. This review consolidates the available studies that discuss all related biological pathways and repair mechanisms that inhibit the progression of deleterious effects at low doses and low dose rates of ionizing radiation. It is pertinent that, taking cognizance of these processes, there is a need to have a relook at policies of radiation protection, which as of now are too stringent, leading to undue economic losses and negative public perception about radiation.


Assuntos
Exposição à Radiação , Proteção Radiológica , Humanos , Relação Dose-Resposta à Radiação , Hormese , Exposição à Radiação/efeitos adversos , Radiação Ionizante
10.
Gynecol Oncol ; 180: 55-62, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38052109

RESUMO

PURPOSE: Curative-intent radiotherapy for locally advanced and select early stage cervical cancer in the US includes external beam radiotherapy (EBRT) with brachytherapy. Although there are guidelines for brachytherapy dose and fractionation regimens, there are limited data on practice patterns. This study aims to evaluate the contemporary utilization of cervical cancer brachytherapy in the US and its association with patient demographics and facility characteristics. METHODS: We retrospectively analyzed clinical covariates of cervical cancer patients diagnosed and treated in 2018-2020 with curative-intent radiotherapy from the 2020 National Cancer Database. Associations between patient and institutional factors with the number of brachytherapy fractions were identified with logistic regression. Factors with association (p < 0.10) were then included in a multivariable logistic regression model. All tests were two-sided with significance <0.05 unless specified otherwise. RESULTS: Among the eligible 2517 patients, 97.3% received HDR or LDR and is further analyzed. More patients received HDR than LDR brachytherapy (98.9% vs 1.1%) and intracavitary than interstitial brachytherapy (86.4% vs 13.6%). The most common number of HDR fractions prescribed were 5 (51.0%), 4 (32.9%), and 3 (8.6%). After adjusting for the other variables in the model, ethnicity, private insurance status, overall insurance status, and facility type were the only factors that were significantly associated with the number of brachytherapy factions (p < 0.0001, p = 0.028, p = 0.001, and p < 0.0001, respectively, n = 2184). CONCLUSIONS: In the US, various HDR brachytherapy regimens are utilized depending on patient and institutional factors. Future research may optimize cervical cancer brachytherapy by correlating specific dose and fractionation regimens with patient outcomes.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Braquiterapia/efeitos adversos , Dosagem Radioterapêutica , Neoplasias do Colo do Útero/tratamento farmacológico , Estudos Retrospectivos , Fracionamento da Dose de Radiação
11.
Phys Med Biol ; 68(23)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37863069

RESUMO

Monte Carlo (MC) dose datasets are valuable for large-scale dosimetric studies. This work aims to build and validate a DICOM-compliant automated MC dose recalculation pipeline with an application to the production of I-125 low dose-rate prostate brachytherapy MC datasets. Built as a self-contained application, the recalculation pipeline ingested clinical DICOM-RT studies, reproduced the treatment into the Monte Carlo simulation, and outputted a traceable and durable dose distribution in the DICOM dose format. MC simulations with TG43-equivalent conditions using both TOPAS andegs_brachyMC codes were compared to TG43 calculations to validate the pipeline. The consistency of the pipeline when generating TG186 simulations was measured by comparing simulations made with both MC codes. Finally,egs_brachysimulations were run on a 240-patient cohort to simulate a large-scale application of the pipeline. Compared to line source TG43 calculations, simulations with both MC codes had more than 90% of voxels with a global difference under ±1%. Differences of 2.1% and less were seen in dosimetric indices when comparing TG186 simulations from both MC codes. The large-scale comparison ofegs_brachysimulations with treatment planning system dose calculation seen the same dose overestimation of TG43 calculations showed in previous studies. The MC dose recalculation pipeline built and validated against TG43 calculations in this work efficiently produced durable MC dose datasets. Since the dataset could reproduce previous dosimetric studies within 15 h at a rate of 20 cases per 25 min, the pipeline is a promising tool for future large-scale dosimetric studies.


Assuntos
Braquiterapia , Radioisótopos do Iodo , Masculino , Humanos , Dosagem Radioterapêutica , Método de Monte Carlo , Próstata , Algoritmos , Planejamento da Radioterapia Assistida por Computador , Radiometria
12.
Clin Med Insights Oncol ; 17: 11795549231201128, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37823009

RESUMO

Background: Numerous studies have shown that polymorphisms in the diabetes susceptibility gene, insulin-like growth factor 2mRNA-binding protein 2 (IGF2BP2), are associated with the occurrence and development of various malignant tumors; however, their correlation with the onset of diffuse large B-cell lymphoma (DLBCL) is still unknown. Therefore, this study aimed to explore whether IGF2BP2 polymorphisms increase the risk of developing DLBCL. Methods: This study included 295 DLBCL patients and 331 healthy individuals. Peripheral blood was collected, and polymerase chain reaction-ligase detection reaction (PCR-LDR) was used to detect IGF2BP2 gene polymorphisms. Logistic regression was used to assess the association between IGF2BP2 polymorphism and the risk of DLBCL, adjusted for age, sex, and body mass index (BMI). P < .05 indicated statistical significance. Results: The rs4402960 polymorphism in the IGF2BP2 gene was associated with the occurrence and development of DLBCL. After adjusting for age, sex, and BMI, GT (odd ratio [OR] = 1.54; 95% confidence interval [CI] = 1.08-2.19; P = .016), TT (OR = 2.00; 95% CI = 1.09-3.68; P = .026), and T genotype carrying (GT + TT) (OR = 1.62; 95% CI = 1.17-2.25; P = .004) significantly increased the risk of DLBCL. This study also found that the polymorphism rs1470579 was related to the development of DLBCL. After adjusting for age, sex, and BMI, AC (OR = 1.55; 95% CI = 1.11-2.17; P = .010), CC (OR = 2.18; 95% CI = 1.17-4.06; P = .014), and C genotype carrying (AC + CC) (OR = 1.64; 95% CI = 1.19-2.26; P = .002) significantly increased the risk of DLBCL. Conclusions: Our study found that polymorphism in the IGF2BP2 gene was associated with an increased risk of developing DLBCL.

13.
Urol Oncol ; 41(11): 454.e17-454.e24, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37714724

RESUMO

BACKGROUND: To validate the subdivision of intermediate-risk (IR) prostate cancer (PCa) into favorable intermediate-risk (FIR) and unfavorable intermediate-risk (UIR) PCa in a historical patient cohort and to compare 2 different radiotherapy regimens. METHODS: Patients with intermediate-risk (IR) PCa, treated either by 125J-LDR-brachytherapy monotherapy (BT) or by combined-modality radiation therapy (CRT), were retrospectively subclassified into FIR and UIR and reanalyzed with regard to biochemical recurrence-free survival (BRFS), metastasis-free survival (MFS), and prostate cancer-specific survival (CSS). Kaplan-Meier product-limit method and log-rank tests were applied to estimate survival probabilities and compare survival, respectively. Uni- and multivariable analyses were performed using Cox proportional hazard regression. RESULTS: Of 490 IR patients, 252 had received BT (86.5% FIR, 13.5% UIR), and 238 had received CRT (30% FIR, 70% UIR). Retrospective analysis revealed that BRFS at 10 years was 81% for BT, and 94% for CRT in FIR patients. For UIR patients, BRFS at 10 years was 37% for BT, and 89% for CRT. MFS at 10 years for FIR patients was 87% for BT, and 94% for CRT. For UIR patients MFS at 10 years was 78% for BT, and 95% for CRT. In multivariable analysis treatment (BT vs. CRT) was the single associated factor for biochemical recurrence, and for metastases in the UIR group (BFRS, P < 0.001, HR 16.07 (CI 4.23-61.10); MFS, P = 0.011, HR 8.43 (CI 1.62-43.9). CONCLUSIONS: Subclassification of IR prostate cancer into FIR and UIR subcategories appears mandatory. For FIR patients, outcomes after BT monotherapy were acceptable. However, clinical failure after 125J-LDR-BT in UIR patients was notably increased, suggesting that BT monotherapy was less successful in this risk group. In contrast, the outcome in UIR patients after CRT was excellent.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Braquiterapia/métodos , Estudos Retrospectivos , Neoplasias da Próstata/patologia , Antígeno Prostático Específico/uso terapêutico , Próstata/patologia
14.
Sensors (Basel) ; 23(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37447764

RESUMO

Precision agriculture is crucial for ensuring food security in a growing global population. Nutrients, their presence, concentration, and effectiveness, are key components in data-driven agriculture. Assessing macro and micro-nutrients, as well as factors such as water and pH, helps determine soil fertility, which is vital for supporting healthy plant growth and high crop yields. Insufficient soil nutrient assessment during continuous cropping can threaten long-term agricultural viability. Soil nutrients need to be measured and replenished after each harvest for optimal yield. However, existing soil testing procedures are expensive and time-consuming. The proposed research aims to assess soil nutrient levels, specifically nitrogen and phosphorus concentrations, to provide critical information and guidance on restoring optimal soil fertility. In this research, a novel chip-level colorimeter is fabricated to detect the N and P elements of soil onto a handheld colorimeter or spectrophotometer. Chemical reaction with soil solution generates color in the presence of nutrients, which are then quantitatively measured using sensors. The test samples are collected from various farmlands, and the results are validated with laboratory analysis of samples using spectrophotometers used in laboratories. ANOVA test has been performed in which F value > 1 in our study indicates statistically significant differences between the group means. The alternate hypothesis, which proposes the presence of significant differences between the groups, is supported by the data. The device created in this paper has crucial potential in terms of environmental and biological applications.


Assuntos
Fósforo , Solo , Fazendas , Fósforo/análise , Nitrogênio/análise , Agricultura/métodos , Fertilizantes/análise
15.
Talanta ; 265: 124881, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37390672

RESUMO

Cell viability is essential for predicting drug toxicity and assessing drug effects in drug screening. However, the over/underestimation of cell viability measured by traditional tetrazolium colorimetric assays is inevitable in cell-based experiments. Hydrogen peroxide (H2O2) secreted by living cells may provide more comprehensive information about the cell state. Hence, it is significant to develop a simple and rapid approach for evaluating cell viability by measuring the excreted H2O2. In this work, we developed a dual-readout sensing platform based on optical and digital signals by integrating a light emitting diode (LED) and a light dependent resistor (LDR) into a closed split bipolar electrode (BPE), denoted as BP-LED-E-LDR, for evaluating cell viability by measuring the H2O2 secreted from living cells in drug screening. Additionally, the customized three-dimensional (3D) printed components were designed to adjust the distance and angle between the LED and LDR, achieving stable, reliable and highly efficient signal transformation. It only took 2 min to obtain response results. For measuring the exocytosis H2O2 from living cells, we observed a good linear relationship between the visual/digital signal and logarithmic function of MCF-7 cell counts. Furthermore, the fitted half inhibitory concentration curve of MCF-7 to doxorubicin hydrochloride obtained by the BP-LED-E-LDR device revealed a nearly identical tendency with the cell counting kit-8 assay, providing an attainable, reusable, and robust analytical strategy for evaluating cell viability in drug toxicology research.


Assuntos
Técnicas Biossensoriais , Peróxido de Hidrogênio , Humanos , Sobrevivência Celular , Contagem de Células , Eletrodos , Células MCF-7 , Técnicas Biossensoriais/métodos
16.
Prostate ; 83(11): 1068-1075, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37150842

RESUMO

PURPOSE: To compare the clinical outcomes of single-fraction high-dose-rate (HDR) brachytherapy and single-fraction low-dose-rate (LDR) brachytherapy as the sole treatment for primary prostate cancer. MATERIAL AND METHODS: A quasi-randomized study that allocated, from March 2008 to February 2012, 129 low and intermediate risk prostate cancer patients to one single-fraction HDR of 19 Gy (61 patients) or to a 145 Gy 125 I LDR permanent implant (68 patients. Biochemical relapse-free survival (bRFS) and overall survival (OS) were compared using the Kaplan-Meier method and Cox regression analysis. RESULTS: After a median follow-up of 72 months in the HDR group, 26 patients relapsed, and after a median follow-up of 84 months in the LDR group, 7 patients relapsed (p < 0.0001). The 5-year bRFS was significantly better for the LDR group than for the HDR group (93.7% and 61.1%, respectively) (p < 0.0001). The 5-year OS also was significantly better in the LDR group (95.5% vs. 89.9%) (p = 0.0436). CONCLUSIONS: Permanent LDR prostate implant brachytherapy offers better clinical outcomes than single-fraction HDR for prostate cancer.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Estudos Prospectivos , Braquiterapia/métodos , Dosagem Radioterapêutica , Recidiva Local de Neoplasia/radioterapia
17.
J Contemp Brachytherapy ; 15(2): 96-102, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37215610

RESUMO

Purpose: International guidelines recommend urethral dose volume constraints to minimize the risk of urinary toxicity after prostate brachytherapy. An association between dose to the bladder neck (BN) and toxicity has previously been reported, and we sought to evaluate the impact of this organ at risk on urinary toxicity, based on intra-operative contouring. Material and methods: Rates of acute and late urinary toxicity (AUT and LUT, respectively) were graded according to CTCAE version 5.0 for 209 consecutive patients who underwent low-dose-rate (LDR) brachytherapy monotherapy, with approximately equal numbers treated before and after we began routinely contouring the BN. AUT and LUT were compared in patients treated before and after we began contouring the OAR, and also for those treated after we began contouring who had a D2cc of greater than or less than 50% prescription dose. Results: AUT and LUT fell after intra-operative BN contouring was instituted. Rates of grade ≥ 2 AUT fell from 15/101 (15%) to 9/104 (8.6%), p = 0.245. Grade ≥ 2 LUT decreased from 32/100 (32%) to 18/100 (18%), p = 0.034. Grade ≥ 2 AUT was observed in 4/63 (6.3%) and 5/34 (15%) of those with a BN D2cc >/≤ 50%, respectively, of prescription dose. Corresponding rates for LUT were 11/62 (18%) and 5/32 (16%). Conclusions: There were lower urinary toxicity rates for patients treated after we commenced routine intra-operative contouring of the BN. No clear relationship was observed between dosimetry and toxicity in our population.

18.
J Contemp Brachytherapy ; 15(2): 103-109, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37215611

RESUMO

Purpose: The incidence of local prostate cancer recurrences after monotherapy with high-dose-rate brachytherapy (HDR-BT) is low. However, a cumulated number of local recurrences during follow-up is naturally observed in highly specialized oncological centers. This retrospective study aimed to present the treatment of local recurrences after HDR-BT with low-dose-rate brachytherapy (LDR-BT). Material and methods: Nine patients with low- and intermediate-risk prostate cancer with a median age of 71 years (range, 59-82 years) were diagnosed with local recurrences after previous monotherapy HDR-BT, 3 × 10.5 Gy (from 2010 to 2013). Median time to biochemical recurrence was 59 months (range, 21-80 months). All patients received 145 Gy with salvage LDR-BT (iodine-125). Gastrointestinal and urological toxicities were evaluated based on patients' records following CTCAE v. 4.0 and IPSS scales. Results: The median follow-up after salvage treatment was 30 months (range, 17-63 months). Local recurrences (LR) were detected in two cases, and the actuarial 2-year local control was 88%. Biochemical failure was observed in four cases. Distant metastases (DM) were observed in 2 patients. In one patient, both LR and DM were diagnosed simultaneously. Four patients had no relapse of the disease, and a 2-year disease-free survival (DSF) was 58.3%. Before salvage treatment, median IPSS scores were 6.5 points (range, 1-23 points). At the first follow-up visit, after one month, the mean IPSS score was 20 points, and at the last follow-up visit, it was 8 points (range, 1-26 points). One patient had urinary retention after treatment. There was no significant change in IPSS scores before and after the treatment (p = 0.68). Two patients had grade 1 toxicity in the gastrointestinal tract. Conclusions: Salvage LDR-BT for patients with prostate cancer previously treated with HDR-BT monotherapy is characterized by acceptable toxicity, and may result in local disease control.

19.
Brachytherapy ; 22(4): 446-460, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37024350

RESUMO

PURPOSE: To provide a systematic review of the applications of 3D printing in gynecological brachytherapy. METHODS: Peer-reviewed articles relating to additive manufacturing (3D printing) from the 34 million plus biomedical citations in National Center for Biotechnology Information (NCBI/PubMed), and 53 million records in Web of Science (Clarivate) were queried for 3D printing applications. The results were narrowed sequentially to, (1) all literature in 3D printing with final publications prior to July 2022 (in English, and excluding books, proceedings, and reviews), and then to applications in, (2) radiotherapy, (3) brachytherapy, (4) gynecological brachytherapy. Brachytherapy applications were reviewed and grouped by disease site, with gynecological applications additionally grouped by study type, methodology, delivery modality, and device type. RESULTS: From 47,541 3D printing citations, 96 publications met the inclusion criteria for brachytherapy, with gynecological clinical applications compromising the highest percentage (32%), followed by skin and surface (19%), and head and neck (9%). The distribution of delivery modalities was 58% for HDR (Ir-192), 35% for LDR (I-125), and 7% for other modalities. In gynecological brachytherapy, studies included design of patient specific applicators and templates, novel applicator designs, applicator additions, quality assurance and dosimetry devices, anthropomorphic gynecological applicators, and in-human clinical trials. Plots of year-to-year growth demonstrate a rapid nonlinear trend since 2014 due to the improving accessibility of low-cost 3D printers. Based on these publications, considerations for clinical use are provided. CONCLUSIONS: 3D printing has emerged as an important clinical technology enabling customized applicator and template designs, representing a major advancement in the methodology for implantation and delivery in gynecological brachytherapy.


Assuntos
Braquiterapia , Radioisótopos do Iodo , Humanos , Dosagem Radioterapêutica , Braquiterapia/métodos , Impressão Tridimensional
20.
Clin Oncol (R Coll Radiol) ; 35(4): 262-268, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36737311

RESUMO

AIMS: To report long-term oncological outcomes of men treated prospectively as part of the American College of Surgeons Oncology Group phase III Surgical Prostatectomy Versus Interstitial Radiation Intervention Trial (SPIRIT) at our institution. MATERIALS AND METHODS: In 2003-2004, patients eligible for SPRIT attended a multidisciplinary educational session, following which they could choose radical prostatectomy, low dose rate brachytherapy (LDR-BT) or randomisation to SPIRIT. Biochemical failure was determined by the accepted definitions of a prostate-specific antigen (PSA) level ≥0.2 ng/ml after radical prostatectomy and the Phoenix definition of PSA ≥2 ng/ml above the nadir after LDR-BT. A sensitivity analysis, using a PSA >0.5 ng/ml to define biochemical failure after LDR-BT and a threshold PSA ≥0.2 ng/ml, was carried out to test the robustness of the results. To account for the competing risk of death, Gray's test was used to test the equality of the cumulative incidence function of biochemical failure between treatment groups. The Kaplan-Meier method was used to estimate overall survival and prostate cancer-specific survival. A P-value ≤0.05 was considered statistically significant. RESULTS: Of 156 patients, 100 received LDR-BT (15 after randomisation) and 56 underwent radical prostatectomy (15 after randomisation). The median follow-up was 12.6 and 14.7 years for LDR-BT and radical prostatectomy, respectively. The median age was 60 years; the median pre-treatment PSA was 5.5 (interquartile range 4.3-7.1). No significant differences in patient characteristics were found between groups. Two patients received adjuvant radiotherapy after radical prostatectomy. The cumulative incidence function of biochemical failure was 0%, 1.1% and 2.4% at 5, 10 and 15 years, respectively, in the LDR-BT arm versus 8.5%, 15.8% and 15.8% in the radical prostatectomy arm (P < 0.001). These results were consistent when varying the definition of biochemical failure defined as PSA ≥0.5 ng/ml (P = 0.01). At 15 years, overall survival was higher in patients treated with radical prostatectomy compared with those treated with LDR-BT; however, no statistical difference was found in prostate cancer-specific survival. CONCLUSION: In low-risk prostate cancer patients, LDR-BT offers excellent long-term oncological outcomes comparable with radical prostatectomy, in addition to the previously reported advantage for LDR-BT in urinary and sexual quality of life domains and patient satisfaction.


Assuntos
Braquiterapia , Neoplasias da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Braquiterapia/métodos , Estudos Prospectivos , Antígeno Prostático Específico , Prostatectomia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Qualidade de Vida , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA