Phys Med Biol ; 2024 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-39168156

RESUMO

Simultaneous PET/MRI provides concurrent information about anatomic, functional, and molecular changes in disease. We are developing a second generation MR-compatible RF-penetrable TOF-PET insert. The insert has a smaller scintillation crystal size and ring diameter compared to clinical whole-body PET scanners, resulting in higher spatial resolution and sensitivity. This paper reports the initial system performance of this full-ring PET insert. The global photopeak energy resolution and global coincidence time resolution, 11.74 ± 0.03 % FWHM and 238.1 ± 0.5 ps FWHM, respectively, are preserved as we scaled up the system to a full ring comprising 12,288 LYSO-SiPM channels. Throughout a ten-hour experiment, the system performance remained stable, exhibiting a less than 1% change in all measured parameters. In a resolution phantom study, the system successfully resolved all 2.8 mm diameter rods, achieving an average VPR of 0.28 ± 0.08 without TOF and 0.24 ± 0.07 with TOF applied. Moreover, the implementation of TOF in the Hoffman phantom study also enhanced image quality. Initial MR compatibility studies of the full PET ring were performed with it unpowered as a milestone to focus on looking for material and geometry-related artifacts. During all MR studies, the MR body coil functioned as both the transmit and receive coil, and no observable artifacts were detected. As expected, using the body coil also as the RF receiver, MR image signal-to-noise ratio exhibited degradation (∼30%), so we are developing a high quality receive-only coil that resides inside the PET ring.

2.
J Biomech ; 169: 112133, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38744146

RESUMO

Abnormal loading is thought to play a key role in the disease progression of cartilage, but our understanding of how cartilage compositional measurements respond to acute compressive loading in-vivo is limited. Ten healthy subjects were scanned at two timepoints (7 ± 3 days apart) with a 3 T magnetic resonance imaging (MRI) scanner. Scanning sessions included T1ρ and T2* acquisitions of each knee in two conditions: unloaded (traditional MRI setup) and loaded in compression at 40 % bodyweight as applied by an MRI-compatible loading device. T1ρ and T2* parameters were quantified for contacting cartilage (tibial and femoral) and non-contacting cartilage (posterior femoral condyle) regions. Significant effects of load were found in contacting regions for both T1ρ and T2*. The effect of load (loaded minus unloaded) in femoral contacting regions ranged from 4.1 to 6.9 ms for T1ρ, and 3.5 to 13.7 ms for T2*, whereas tibial contacting regions ranged from -5.6 to -1.7 ms for T1ρ, and -2.1 to 0.7 ms for T2*. Notably, the responses to load in the femoral and tibial cartilage revealed opposite effects. No significant differences were found in response to load between the two visits. This is the first study that analyzed the effects of acute loading on T1ρ and T2* measurements in human femoral and tibial cartilage separately. The results suggest the effect of acute compressive loading on T1ρ and T2* was: 1) opposite in the femoral and tibial cartilage; 2) larger in contacting regions than in non-contacting regions of the femoral cartilage; and 3) not different visit-to-visit.


Assuntos
Cartilagem Articular , Fêmur , Imageamento por Ressonância Magnética , Tíbia , Suporte de Carga , Humanos , Cartilagem Articular/fisiologia , Cartilagem Articular/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Masculino , Adulto , Feminino , Imageamento por Ressonância Magnética/métodos , Tíbia/diagnóstico por imagem , Tíbia/fisiologia , Suporte de Carga/fisiologia , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem , Força Compressiva/fisiologia
4.
Res Sq ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38410479

RESUMO

Accurate perception of tactile information is essential for performing activities of daily living and learning new sensorimotor skills like writing. Deficits in perceiving tactile stimuli are associated with severity in physical disability. The mechanisms contributing to tactile deficits in individuals with brain injuries remain poorly understood in part due to insufficient assessment methods. Here, we provide a tactile stimulator system for studying the neural mechanisms contributing to tactile deficits in individuals with brain injuries during functional magnetic resonance imaging (fMRI). This tactile stimulator system consists of a pneumatically-controlled inflatable and deflatable balloon that interfaces with a digit of the hand to provide small forces. The magnitude of the applied force is delivered and controlled by modifying the air pressure in the balloon. The tactile simulator provides an 8 mm diameter tactile stimulus. The device's interface at the finger is compact, allowing it to be used with individuals who have a closed-fist posture following brain injury such as stroke or cerebral palsy. The tactile stimulator contains no metallic components and can be used in MRI research. The tactile stimulator system can repeatedly apply a force between 1 N and 2.4 N. This tactile stimulator system addresses limitations in past fMRI methodologies for assessing tactile perception by providing precise and repeatable force stimuli to a small area of the finger. Custom software automates the application of the force stimuli and permits synchronization with acquired fMRI data. This system can be used in subsequent testing to investigate deficits in sensory functioning in those with brain injuries.

5.
Eur J Nucl Med Mol Imaging ; 51(2): 346-357, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37782321

RESUMO

PURPOSE: Positron emission tomography/magnetic resonance imaging (PET/MRI) is a powerful tool for brain imaging, but the spatial resolution of the PET scanners currently used for brain imaging can be further improved to enhance the quantitative accuracy of brain PET imaging. The purpose of this study is to develop an MR-compatible brain PET scanner that can simultaneously achieve a uniform high spatial resolution and high sensitivity by using dual-ended readout depth encoding detectors. METHODS: The MR-compatible brain PET scanner, named SIAT bPET, consists of 224 dual-ended readout detectors. Each detector contains a 26 × 26 lutetium yttrium oxyorthosilicate (LYSO) crystal array of 1.4 × 1.4 × 20 mm3 crystal size read out by two 10 × 10 silicon photomultiplier (SiPM) arrays from both ends. The scanner has a detector ring diameter of 376.8 mm and an axial field of view (FOV) of 329 mm. The performance of the scanner including spatial resolution, sensitivity, count rate, scatter fraction, and image quality was measured. Imaging studies of phantoms and the brain of a volunteer were performed. The mutual interferences of the PET insert and the uMR790 3 T MRI scanner were measured, and simultaneous PET/MRI imaging of the brain of a volunteer was performed. RESULTS: A spatial resolution of better than 1.5 mm with an average of 1.2 mm within the whole FOV was obtained. A sensitivity of 11.0% was achieved at the center FOV for an energy window of 350-750 keV. Except for the dedicated RF coil, which caused a ~ 30% reduction of the sensitivity of the PET scanner, the MRI sequences running had a negligible effect on the performance of the PET scanner. The reduction of the SNR and homogeneity of the MRI images was less than 2% as the PET scanner was inserted to the MRI scanner and powered-on. High quality PET and MRI images of a human brain were obtained from simultaneous PET/MRI scans. CONCLUSION: The SIAT bPET scanner achieved a spatial resolution and sensitivity better than all MR-compatible brain PET scanners developed up to date. It can be used either as a standalone brain PET scanner or a PET insert placed inside a commercial whole-body MRI scanner to perform simultaneous PET/MRI imaging.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Desenho de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem
6.
Med Phys ; 50(12): 8063-8068, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37665757

RESUMO

BACKGROUND: During and after exercise, dynamic 31 P MR parameters are typically measured using an MR-compatible ergometer. Self-built equipment for local condition can be constructed where possible. PURPOSE: To develop a pedal resistance ergometer with rocker arm based on a system that combines electric weight displacement, visual self-monitoring, and exercise triggering. The repeatability and reproducibility were tested. METHODS: The hardware and software for the ergometer were constructed from commercial components in a home laboratory. Twelve volunteers participated in the testing of the ergometer. RESULTS: A fully automated ergometer system was developed, allowing the pedal resistance to be adjusted during the examination. The system includes a self-monitoring and triggering mechanism that enables both the operator and subject to monitor pedal frequency and force. The operator can modify the pedal resistance as desired during the exercise. This self-monitoring solution is simple and cost-effective, requiring only a commercial potentiometer, an Arduino converter, and a conventional video projector with a personal computer (PC). Additionally, all system components are located outside the magnetic resonance (MR) room, avoiding interference with the MR system. Results of several test of the reproducibility/repeatability of power at three pedal resistance values (15%, 24%, 25% maximal voluntary force) were expressed both as a coefficient of variation ranging from 6% to 3.1% and as an intraclass correlation of coefficient ranging from 0.96 to 0.99. Similar values were also found for other dynamic parameters of 31 P MR spectroscopy. These findings are similar to published data obtained on different types of ergometers. CONCLUSIONS: Based on more than 1 year of usage, the ergometer proved successful in handling stationary and variable loads, and can be easily operated by a single user.


Assuntos
Retroalimentação Sensorial , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Espectroscopia de Ressonância Magnética/métodos , Exercício Físico
7.
Med Phys ; 50(6): 3389-3400, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36912373

RESUMO

BACKGROUND: Simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI) has shown promise in acquiring complementary multiparametric information of disease. However, designing these hybrid imaging systems is challenging due to the propensity for mutual interference between the PET and MRI subsystems. Currently, there are integrated PET/MRI systems for clinical applications. For neurologic imaging, a brain-dedicated PET insert provides superior spatial resolution and sensitivity compared to body PET scanners. PURPOSE: Our first-generation prototype brain PET insert ("PETcoil") demonstrated RF-penetrability and MR-compatibility. In the second-generation PETcoil system, all analog silicon photomultiplier (SiPM) signal digitization is moved inside the detectors, which results in substantially better PET detector performance, but presents a greater technical challenge for achieving MR-compatibility. In this paper, we report results from MR-compatibility studies of two fully assembled second-generation PET insert detector modules. METHODS: We studied the effect of the presence of the two second-generation TOF-PET insert detectors on parameters that affect MR image quality and evaluated TOF-PET detector performance under different MRI pulse sequence conditions. RESULTS: With the presence of operating PET detectors, no RF noise peaks were induced in the MR images, but the relative average noise level was increased by 15%, which led to a 3.1 to 4.2-dB degradation in MR image signal-to-noise ratio (SNR). The relative homogeneity of MR images degraded by less than 1.5% with the two operating TOF-PET detectors present. The reported results also indicated that ghosting artifacts (percent signal ghosting (PSG) ⩽ 1%) and MR susceptibility artifacts (0.044 ppm) were insignificant. The PET detector data showed a relative change of less than 5% in detector module performance between running outside and within the MR bore under different MRI pulse sequences except for energy resolution in EPI sequence (13% relative difference). CONCLUSIONS: The PET detector operation did not cause any significant artifacts in MR images and the performance and time-of-flight (TOF) capability of the former were preserved under different tested MR conditions.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Razão Sinal-Ruído , Imagens de Fantasmas
8.
Phys Med Biol ; 68(8)2023 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-36913739

RESUMO

Objective. We are developing a portable, 'RF-penetrable', brain-dedicated time of flight (TOF)-PET insert (PETcoil) for simultaneous PET/MRI.Approach. In this paper, we evaluate the PET performance of two fully assembled detector modules for this insert design outside the MR room.Main results. The global coincidence time resolution, global 511 keV energy resolution, coincidence count rate, and detector temperature achieved over 2 h data collection were 242.2 ± 0.4 ps full width at half maximum (FWHM), 11.19% ± 0.02% FWHM, 22.0 ± 0.1 kcps, and 23.5 °C ± 0.3 °C, respectively. The intrinsic spatial resolutions in the axial and transaxial directions were 2.74 ± 0.01 mm FWHM and 2.88 ± 0.03 mm FWHM, respectively.Significance. These results demonstrate excellent TOF capability and the performance and stability necessary for scaling up to a full ring comprising 16 detector modules.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas , Temperatura
9.
Front Neurosci ; 17: 1071749, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36777636

RESUMO

Functional magnetic resonance imaging (fMRI) has been extensively used as a tool to map the brain processes related to somatosensory stimulation. This mapping includes the localization of task-related brain activation and the characterization of brain activity dynamics and neural circuitries related to the processing of somatosensory information. However, the magnetic resonance (MR) environment presents unique challenges regarding participant and equipment safety and compatibility. This study aims to systematically review and analyze the state-of-the-art methodologies to assess the safety and compatibility of somatosensory stimulation devices in the MR environment. A literature search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement guidelines, was performed in PubMed, Scopus, and Web of Science to find original research on the development and testing of devices for somatosensory stimulation in the MR environment. Nineteen records that complied with the inclusion and eligibility criteria were considered. The findings are discussed in the context of the existing international standards available for the safety and compatibility assessment of devices intended to be used in the MR environment. In sum, the results provided evidence for a lack of uniformity in the applied testing methodologies, as well as an in-depth presentation of the testing methodologies and results. Lastly, we suggest an assessment methodology (safety, compatibility, performance, and user acceptability) that can be applied to devices intended to be used in the MR environment. Systematic review registration: https://www.crd.york.ac.uk/prospero/, identifier CRD42021257838.

10.
Magn Reson Med ; 88(4): 1927-1936, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35649186

RESUMO

PURPOSE: To develop a compact MR-compatible ergometer for exercise stress and to initially evaluate the reproducibility of myocardial native T1 and myocardial blood flow (MBF) measurements during exercise stress performed on this ergometer. METHODS: The compact ergometer consists of exercise, workload, and data processing components. The exercise stress can be achieved by pedaling on a pair of cylinders at a predefined frequency with adjustable resistances. Ten healthy subjects were recruited to perform cardiac MRI scans twice in a 3.0T MR scanner, at different days to assess reproducibility. Myocardial native T1 and MBF were acquired at rest and during a moderate exercise. The reproducibility of the two tests was determined by the intra-group correlation coefficient (ICC) and coefficient of variation (CoV). RESULTS: The mean exercise intensity in this pilot study was 45 Watts (W), with an exercise duration of 5 min. Stress induced a significant increase in systolic blood pressure (from 113 ± 11 mmHg to 141 ± 12, P < 0.05) and maximal increase in heart rate by 74 ± 19%. The rate pressure product increased two-fold (P < 0.001). Excellent reproducibility was demonstrated in native T1 during the exercise (CoV = 3.0%), whereas the reproducibility of MBF and myocardial perfusion reserve during the exercise was also good (CoV = 10.7% and 8.8%, respectively). CONCLUSION: This pilot study demonstrated that it is possible to acquire reproducible measurements of myocardial native T1 and MBF during the exercise stress in healthy volunteers using our new compact ergometer.


Assuntos
Circulação Coronária , Teste de Esforço , Circulação Coronária/fisiologia , Humanos , Imageamento por Ressonância Magnética , Projetos Piloto , Reprodutibilidade dos Testes
11.
Med Phys ; 49(7): 4365-4371, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35635215

RESUMO

BACKGROUND: In magnetic resonance (MR)-guided thermal therapy, respiratory motion can cause a significant temperature error in MR thermometry and reduce the efficiency of the treatment. A respiratory motion simulator is necessary for the development of new MR imaging (MRI) and motion compensation techniques. PURPOSE: The purpose of this study is to develop a low-cost and simple MR-compatible respiratory motion simulator to support proof-of-concept studies of MR monitoring approaches with respiratory-induced abdominal organ motion. METHODS: The phantom motion system integrates pneumatic control via an actuator subsystem located outside the MRI and coupled via plastic tubing to a compressible bag for distention and retraction within the MRI safe motion subsystem and phantom positioned within the MRI scanner. Performance of the respiratory motion simulator was evaluated with a real-time gradient echo MRI pulse sequence. RESULTS: The motion simulator can produce respiratory rates in the range of 8-16 breaths/min. Our experiments showed the consistent periodic motion of the phantom during MRI acquisition in the range of 3.7-9 mm with 16 breaths/min. The operation of the simulator did not cause interference with MRI acquisition. CONCLUSIONS: In this study, we have demonstrated the ability of the motion simulator to generate controlled respiratory motion of a phantom. The low-cost MR-compatible respiratory motion simulator can be easily constructed from off-the-shelf and 3D-printed parts based on open-source 3D models and instructions. This could lower the barriers to the development of new MRI techniques with motion compensation.


Assuntos
Imageamento por Ressonância Magnética , Movimentos dos Órgãos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Movimento (Física) , Imagens de Fantasmas
12.
Open Neuroimag J ; 14: 8-15, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34434290

RESUMO

BACKGROUND: Ischemic stroke is the most common cause of complex chronic disability and the third leading cause of death worldwide. In recovering stroke patients, peak activation within the ipsilesional primary motor cortex (M1) during the performance of a simple motor task has been shown to exhibit an anterior shift in many studies and a posterior shift in other studies. OBJECTIVE: We investigated this discrepancy in chronic stroke patients who completed a robot-assisted rehabilitation therapy program. METHODS: Eight chronic stroke patients with an intact M1 and 13 Healthy Control (HC) volunteers underwent 300 functional magnetic resonance imaging (fMRI) scans while performing a grip task at different force levels with a robotic device. The patients were trained with the same robotic device over a 10-week intervention period and their progress was evaluated serially with the Fugl-Meyer and Modified Ashworth scales. Repeated measure analyses were used to assess group differences in locations of peak activity in the sensorimotor cortex (SM) and the relationship of such changes with scores on the Fugl-Meyer Upper Extremity (FM UE) scale. RESULTS: Patients moving their stroke-affected hand had proportionally more peak activations in the primary motor area and fewer peak activations in the somatosensory cortex than the healthy controls (P=0.009). They also showed an anterior shift of peak activity on average of 5.3-mm (P<0.001). The shift correlated negatively with FM UE scores (P=0.002). CONCLUSION: A stroke rehabilitation grip task with a robotic device was confirmed to be feasible during fMRI scanning and thus amenable to be used to assess plastic changes in neurological motor activity. Location of peak activity in the SM is a promising clinical neuroimaging index for the evaluation and monitoring of chronic stroke patients.

13.
EJNMMI Phys ; 8(1): 47, 2021 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-34117943

RESUMO

BACKGROUND: Integrated whole-body PET/MR technology continues to mature and is now extensively used in clinical settings. However, due to the special design architecture, integrated whole-body PET/MR comes with a few inherent limitations. Firstly, whole-body PET/MR lacks sensitivity and resolution for focused organs. Secondly, broader clinical access of integrated PET/MR has been significantly restricted due to its prohibitively high cost. The MR-compatible PET insert is an independent and removable PET scanner which can be placed within an MRI bore. However, the mobility and configurability of all existing MR-compatible PET insert prototypes remain limited. METHODS: An MR-compatible portable PET insert prototype, dual-panel portable PET (DP-PET), has been developed for simultaneous PET/MR imaging. Using SiPM, digital readout electronics, novel carbon fiber shielding, phase-change cooling, and MRI compatible battery power, DP-PET was designed to achieve high-sensitivity and high-resolution with compatibility with a clinical 3-T MRI scanner. A GPU-based reconstruction method with resolution modeling (RM) has been developed for the DP-PET reconstruction. We evaluated the system performance on PET resolution, sensitivity, image quality, and the PET/MR interference. RESULTS: The initial results reveal that the DP-PET prototype worked as expected in the MRI bore and caused minimal compromise to the MRI image quality. The PET performance was measured to show a spatial resolution ≤ 2.5 mm (parallel to the detector panels), maximum sensitivity = 3.6% at the center of FOV, and energy resolution = 12.43%. MR pulsing introduces less than 2% variation to the PET performance measurement results. CONCLUSIONS: We developed a MR-compatible PET insert prototype and performed several studies to begin to characterize the performance of the proposed DP-PET. The results showed that the proposed DP-PET performed well in the MRI bore and would cause little influence on the MRI images. The Derenzo phantom test showed that the proposed reconstruction method could obtain high-quality images using DP-PET.

14.
Int J Med Robot ; 17(4): e2257, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33817973

RESUMO

BACKGROUND: The brain of sheep has primarily been used in neuroscience as an animal model because of its similarity to the human brain, in particular if compared to other models such as the lissencephalic rodent brain. Their brain size also makes sheep an ideal model for the development of neurosurgical techniques using conventional clinical CT/MRI scanners and stereotactic systems for neurosurgery. METHODS: In this study, we present the design and validation of a new CT/MRI compatible head frame for the ovine model and software, with its assessment under two real clinical scenarios. RESULTS: Ex-vivo and in vivo trial results report an average linear displacement of the ovine head frame during conventional surgical procedures of 0.81 mm for ex-vivo trials and 0.68 mm for in vivo tests, respectively. CONCLUSIONS: These trial results demonstrate the robustness of the head frame system and its suitability to be employed within a real clinical setting.


Assuntos
Imageamento por Ressonância Magnética , Neurocirurgia , Animais , Humanos , Modelos Animais , Procedimentos Neurocirúrgicos , Ovinos , Tomografia Computadorizada por Raios X
15.
Artigo em Inglês | MEDLINE | ID: mdl-35237771

RESUMO

Many surgeons are faced with inoperable or only partially operable brain lesions, such as tumors. Even when surgery is feasible, patient outcome is greatly affected by blood loss or infection. This has led many physicians toward non- or minimally-invasive surgery, which demands specialized toolkits. Focused ultrasound has great potential for assisting in such procedures due to its ability to focus a few cm away from the surface of the transducer. In a prior study, we developed a focused ultrasound prototype that could fit within a BrainPath trocar, specifically made for minimally invasive brain surgery. Here, we present the design and fabrication of a second prototype that reduces size, is MR-compatible, and has electronic steering capabilities.

16.
Hum Brain Mapp ; 42(1): 128-138, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33089953

RESUMO

The purpose of this study was to develop and evaluate a new, open-source MR-compatible device capable of assessing unipedal and bipedal lower extremity movement with minimal head motion and high test-retest reliability. To evaluate the prototype, 20 healthy adults participated in two magnetic resonance imaging (MRI) visits, separated by 2-6 months, in which they performed a visually guided dorsiflexion/plantar flexion task with their left foot, right foot, and alternating feet. Dependent measures included: evoked blood oxygen level-dependent (BOLD) signal in the motor network, head movement associated with dorsiflexion/plantar flexion, the test-retest reliability of these measurements. Left and right unipedal movement led to a significant increase in BOLD signal compared to rest in the medial portion of the right and left primary motor cortex (respectively), and the ipsilateral cerebellum (FWE corrected, p < .001). Average head motion was 0.10 ± 0.02 mm. The test-retest reliability was high for the functional MRI data (intraclass correlation coefficients [ICCs]: >0.75) and the angular displacement of the ankle joint (ICC: 0.842). This bipedal device can robustly isolate activity in the motor network during alternating plantarflexion and dorsiflexion with minimal head movement, while providing high test-retest reliability. Ultimately, these data and open-source building instructions will provide a new, economical tool for investigators interested in evaluating brain function resulting from lower extremity movement.


Assuntos
Cerebelo/fisiologia , Técnicas de Diagnóstico Neurológico/instrumentação , Desenho de Equipamento/normas , Neuroimagem Funcional , Movimentos da Cabeça/fisiologia , Extremidade Inferior/fisiologia , Atividade Motora/fisiologia , Córtex Motor/fisiologia , Rede Nervosa/fisiologia , Desempenho Psicomotor/fisiologia , Adulto , Cerebelo/diagnóstico por imagem , Feminino , Neuroimagem Funcional/normas , Humanos , Imageamento por Ressonância Magnética , Masculino , Córtex Motor/diagnóstico por imagem , Rede Nervosa/diagnóstico por imagem , Reprodutibilidade dos Testes , Adulto Jovem
17.
Phys Med ; 80: 259-266, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33220650

RESUMO

MR-integrated radiotherapy requires suitable dosimetry detectors to be used in magnetic fields. This study investigates the feasibility of using dedicated MR-compatible ionization chambers at MR-integrated radiotherapy devices. MR-compatible ionization chambers (Exradin A19MR, A1SLMR, A26MR, A28MR) were precisely modeled and their relative response in a 6MV treatment beam in the presence of a magnetic field was simulated using EGSnrc. Monte Carlo simulations were carried out with the magnetic field in three orientations: the magnetic field aligned perpendicular to the chamber and beam axis (transverse orientation), the magnetic field parallel to the chamber as well as parallel to the beam axis. Monte Carlo simulation results were validated with measurements using an electromagnet with magnetic field strength upto 1.1 T with the chambers in transverse orientation. The measurements and simulation results were in good agreement, except for the A26MR ionization chamber in transverse orientation. The maximum increase in response of the ionization chambers observed was 8.6% for the transverse orientation. No appreciable change in chamber response due to the magnetic field was observed for the magnetic field parallel to the ionization chamber and parallel to the photon beam. Polarity and recombination correction factor were experimentally investigated in the transverse orientation. The polarity effect and recombination effect were not altered by a magnetic field. This study further investigates the response of the ionization chambers as a function of the chambers' rotation around their longitudinal axis. A variation in response was observed when the chamber was not rotationally symmetric, which was independent of the magnetic field.


Assuntos
Campos Magnéticos , Aceleradores de Partículas , Radiometria , Simulação por Computador , Método de Monte Carlo
18.
Sensors (Basel) ; 20(21)2020 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-33114180

RESUMO

Grasping is one of the first dominant motor behaviors that enable interaction of a newborn infant with its surroundings. Although atypical grasping patterns are considered predictive of neuromotor disorders and injuries, their clinical assessment suffers from examiner subjectivity, and the neuropathophysiology is poorly understood. Therefore, the combination of technology with functional magnetic resonance imaging (fMRI) may help to precisely map the brain activity associated with grasping and thus provide important insights into how functional outcomes can be improved following cerebral injury. This work introduces an MR-compatible device (i.e., smart graspable device (SGD)) for detecting grasping actions in newborn infants. Electromagnetic interference immunity (EMI) is achieved using a fiber Bragg grating sensor. Its biocompatibility and absence of electrical signals propagating through the fiber make the safety profile of the SGD particularly favorable for use with fragile infants. Firstly, the SGD design, fabrication, and metrological characterization are described, followed by preliminary assessments on a preterm newborn infant and an adult during an fMRI experiment. The results demonstrate that the combination of the SGD and fMRI can safely and precisely identify the brain activity associated with grasping behavior, which may enable early diagnosis of motor impairment and help guide tailored rehabilitation programs.


Assuntos
Força da Mão , Imageamento por Ressonância Magnética , Adulto , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Materiais Inteligentes
19.
J Perinat Med ; 48(7): 733-743, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-32710720

RESUMO

Objectives MR compatible incubators (MRcI) offer the examination of preterm and critically ill infants in controlled environment. The aim of the study was to compare objective and subjective image quality as well as diagnostic value of MRI brain examinations with and without using the MRcI. Thus, predictive value of brain MRI at expected delivery date in general was investigated. Methods This retrospective study included MRI brain examinations conducted at patients' corrected age ≤6 months and presence of four standard sequences (PD TSE transversal, T2 TSE transversal, T2 TSE sagittal and T1 SE transversal). Signal-to-Noise Ratio (SNR) and Contrast-to-Noise Ratio (CNR) was calculated. Subjective image quality was estimated using a 5-point Likert scale. Findings of MRI were compared with those of previous transfontanellar ultrasound because of additional diagnostic information. Severe brain abnormality scaled by score of Kidokoro was related to results of Munich Functional Developmental Diagnostics (MFDD) within first year. Results One hundred MRI brain examinations (76 with MRcI, 24 without MRcI) were performed in 79 patients. Using the MRcI SNR and CNR were significantly higher in PD- and in T2-weighted sequences (p<0.05). TSE PD transversal demonstrated a higher risk of non-diagnostic quality using MRcI (OR 5.23; 95%-CI 1.86-14.72). MRcI revealed additional diagnostic information (OR 5.69; 95%-CI 1.15-28.24). Severe brain abnormality was associated with walking deficits (r=0.570; p=0.021). Conclusions The MRcI increased objective image quality and revealed additional diagnostic information to transfontanellar ultrasound. Nevertheless, prediction of infants' future development remains limited.


Assuntos
Encefalopatias/diagnóstico por imagem , Lesões Encefálicas/diagnóstico , Encéfalo/diagnóstico por imagem , Aumento da Imagem/métodos , Incubadoras para Lactentes , Imageamento por Ressonância Magnética , Traumatismos do Nascimento/diagnóstico , Diagnóstico Precoce , Desenho de Equipamento , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Limite de Detecção , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Transtornos do Neurodesenvolvimento/prevenção & controle , Valor Preditivo dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
20.
Adv Clin Exp Med ; 28(7): 945-954, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31111693

RESUMO

BACKGROUND: The use of a specialized MR-compatible incubator (INC) is very poorly described in the literature and only with regard to brain imaging. OBJECTIVES: To present our own experience with brain and body magnetic resonance imaging (MRI) in the INC in a large cohort of neonates. MATERIAL AND METHODS: A total of 555 examinations were performed in 530 newborns with the use of a 1.5T system and Nomag IC 1.5 incubator, equipped with head and body coils. RESULTS: More than half of neonates (54%) were prematurely born at 22 + 6-36 + 6 gestational weeks. They were examined from the first to 153 days of life (median: 18.5, mean: 37.7) with body weights 600-5000 g (mean: 3051 g), 23% of less than 2500 g. The proportion of brain MRIs to other body regions was 533:85 = 86%:14%. In 36.6% of cases, MRI showed more abnormalities than ultrasound (USG), in a further 21.8%, MRI diagnosis was completely different, in 4.7%, a pathology described on a USG was ruled out on MRI. The superiority of MRI over USG was 63.1%. CONCLUSIONS: MR-compatible incubator significantly increased the availability of MRI to newborns, especially to premature and unstable newborns. The integration of body coils into the INC increased the spectrum of examinations and made possible the scanning not only of the brain but also the body. Dedicated neonatal coils improved image quality and allowed more accurate diagnosis than the previously used adult coils. Immobilization of the babies in the INC by means of Velcro belts and head fixation inserts is better than in adult coils. The closed space of the INC isolates newborns to a greater extent from the negative influence of noise in the MR environment.


Assuntos
Incubadoras para Lactentes , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Imagem Corporal Total , Encéfalo , Humanos , Recém-Nascido , Neuroimagem/métodos