Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-36901489

RESUMO

Novel treatment options for uterine fibroids, such as uterine artery embolization (UAE), ultrasound-guided and magnetic resonance-guided high-intensity focused ultrasound (USgHIFU and MRgHIFU), and transcervical radiofrequency ablation (TFA) methods, are widely used in clinical practice. This systematic review and meta-analysis (CRD42022297312) aims to assess and compare reproductive and obstetric outcomes in women who underwent these minimally invasive approaches for uterine fibroids. The search was performed in PubMed, Google Scholar, ScienceDirect, Cochrane Library, Scopus, Web of Science and Embase. Risk of bias was assessed using the Newcastle-Ottawa Scale (NOS) and Cochrane guidelines. The articles were selected to meet the following eligibility criteria: (1) research article, (2) human subject research, and (3) the study of pregnancy outcomes after the treatment of uterine fibroids by either one of three methods-UAE, HIFU, and TFA. The analysis of 25 eligible original articles shows a similar rate of live births for UAE, USgHIFU, MRgHIFU, and TFA (70.8%, 73.5%, 70%, and 75%, respectively). The number of pregnancies varied considerably among these studies, as well as the mean age of pregnant women. However, the results of pregnancy outcomes for TFA are insufficient to draw firm conclusions, since only 24 women became pregnant in these studies, resulting in three live births. The miscarriage rate was highest in the UAE group (19.2%). USgHIFU was associated with a higher rate of placental abnormalities compared to UAE (2.8% vs. 1.6%). The pooled estimate of pregnancies was 17.31% to 44.52% after UAE, 18.69% to 78.53% after HIFU, and 2.09% to 7.63% after TFA. The available evidence confirmed that these minimally invasive uterine-sparing treatment options for uterine fibroids are a good approach for patients wishing to preserve their fertility, with comparable reproductive and obstetric outcomes among the different techniques.


Assuntos
Leiomioma , Embolização da Artéria Uterina , Neoplasias Uterinas , Feminino , Humanos , Gravidez , Embolização da Artéria Uterina/métodos , Resultado do Tratamento , Placenta
2.
Med Phys ; 49(12): 7373-7383, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36156266

RESUMO

PURPOSE: In this study, we examine the effects of a recently developed, iron-based coupling medium (IBCM) on guidance magnetic resonance (MR) scans during transcranial, magnetic-resonance-guided, focused ultrasound surgery (tMRgFUS) procedures. More specifically, this study tests the hypotheses that the use of the IBCM will (a) not adversely affect image quality, (b) remove aliasing from small field-of-view scans, and (c) decouple image quality from the motion state of the coupling fluid. METHODS: An IBCM, whose chemical synthesis and characterization are reported elsewhere, was used as a coupling medium during tMRgFUS procedures on gel phantoms. Guidance magnetization-prepared rapid-gradient-echo (MP-RAGE), TSE, and GRE scans were acquired with fields of view of 28 and 18 cm. Experiments were repeated with the IBCM in several distinct flow states. GRE scans were used to estimate temperature time courses as a gel target was insonated. IBCM performance was measured by computing (i) the root mean square difference (RMSD) of TSE and GRE pixel values acquired using water and the IBCM, relative to the use of water; (ii) through-time temperature uncertainty for GRE scans; and (iii) Bland-Altman analysis of the temperature time courses. Finally, guidance TSE and GRE scans of a human volunteer were acquired during a separate sham tMRgFUS procedure. As a control, all experiments were repeated using a water coupling medium. RESULTS: Use of the IBCM reduced RMSD in TSE scans by a factor of 4 or more for all fields of view and nonstationary motion states, but did not reduce RMSD estimates in MP-RAGE scans. With the coupling media in a stationary state, the IBCM altered estimates of temperature uncertainty relative to the use of water by less than 0.2°C. However, with a high flow state, the IBCM reduced temperature uncertainties by the statistically significant amounts (at the 0.01 level) of 0.5°C (28 cm field of view) and 5°C (18 cm field of view). Bland-Altman analyses found a 0.1°C ± 0.5°C difference between temperature estimates acquired using water and the IBCM as coupling media. Finally, scans of a human volunteer using the IBCM indicate more conspicuous grey/white matter contrast, a reduction in aliasing, and a less than 0.2°C change in temperature uncertainty. CONCLUSIONS: The use of an IBCM during tMRgFUS procedures does not adversely affect image quality for TSE and GRE scans, can decouple image quality from the motion state of the coupling fluid, and can remove aliasing from scans where the field of view is set to be much smaller than the spatial extent of the coupling fluid.


Assuntos
Ferro , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura , Água , Meios de Contraste
3.
Int J Hyperthermia ; 38(1): 498-510, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33757406

RESUMO

PURPOSE: To evaluate the targetability of late-stage cervical cancer by magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU)-induced hyperthermia (HT) as an adjuvant to radiation therapy (RT). METHODS: Seventy-nine cervical cancer patients (stage IIIB-IVA) who received RT with lesions visible on positron emission tomography-computed tomography (PET-CT) were retrospectively analyzed for targetability using a commercially-available HT-capable MRgHIFU system. Targetability was assessed for both primary targets and/or any metastatic lymph nodes using both posterior (supine) and anterior (prone) patient setups relative to the transducer. Thirty-four different angles of rotation along subjects' longitudinal axis were analyzed. Targetability was categorized as: (1) Targetable with/without minimal intervention; (2) Not targetable. To determine if any factors could be used for prospective screening of patients, potential associations between demographic/anatomical factors and targetability were analyzed. RESULTS: 72.15% primary tumors and 33.96% metastatic lymph nodes were targetable from at least one angle. 49.37% and 39.24% of primary tumors could be targeted with patient laying in supine and prone positions, respectively. 25°-30° rotation and 0° rotation had the highest rate of the posterior and anterior targetability, respectively. The ventral depth of the tumor and its distance to the coccyx were statistically correlated with the anterior and posterior targetability, respectively. CONCLUSION: Most late-stage cervical cancer primaries were targetable by MRgHIFU HT requiring either no/minimal intervention. A rotation of 0° or 25°-30° relative to the transducer might benefit anterior and posterior targetability, respectively. Certain demographic/anatomic parameters might be useful in screening patients for treatability.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Neoplasias do Colo do Útero , Feminino , Humanos , Hipertermia , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
4.
Neurol India ; 68(Supplement): S202-S205, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33318351

RESUMO

Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU) is a well-established technology that has been developed during the last decade and is currently used in the treatment of a diverse range of neurodegenerative brain disorders and neuropsychiatric diseases. This innovative noninvasive technology uses nonionizing ultrasound waves to heat and thus ablate brain tissue in selected targets. In comparison with other lesioning and surgical techniques, MRgHIFU has the following advantages: noninvasive, an immediate clinical outcome with no risk of long-standing ionizing radiation injury, no need for general anesthesia, and no device implantation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade , Transtornos dos Movimentos , Encéfalo , Humanos , Imageamento por Ressonância Magnética , Ultrassonografia
5.
Adv Drug Deliv Rev ; 163-164: 157-167, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33203538

RESUMO

Local application of hyperthermia has a myriad of effects on the tumor microenvironment as well as the host's immune system. Ablative hyperthermia (typically > 55 °C) has been used both as monotherapy and adjuvant therapy, while mild hyperthermia treatment (39-45 °C) demonstrated efficacy as an adjuvant therapy through enhancement of both chemotherapy and radiation therapy. Clinical integration of hyperthermia has especially great potential in pediatric oncology, where current chemotherapy regimens have reached maximum tolerability and the young age of patients implies significant risks of late effects related to therapy. Furthermore, activation of both local and systemic immune response by hyperthermia suggests that hyperthermia treatments could be used to enhance the anticancer effects of immunotherapy. This review summarizes the state of current applications of hyperthermia in pediatric oncology and discusses the use of hyperthermia in the context of other available treatments and promising pre-clinical research.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Hipertermia Induzida/métodos , Neoplasias/tratamento farmacológico , Pediatria , Distúrbios no Reparo do DNA/patologia , Ablação por Ultrassom Focalizado de Alta Intensidade , Humanos , Sistema Imunitário/fisiologia , Lipossomos/química , Instabilidade de Microssatélites , Micro-Ondas/uso terapêutico , Microambiente Tumoral/fisiologia , Ultrassonografia/métodos
6.
Cureus ; 12(8): e9820, 2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-32953330

RESUMO

Functional disorders of the central nervous system (CNS) are diverse in terms of their etiology and symptoms, however, they can be quite debilitating. Many functional neurological disorders can progress to a level where pharmaceuticals and other early lines of treatment can no longer optimally treat the condition, therefore requiring surgical intervention. A variety of stereotactic and functional neurosurgical approaches exist, including deep brain stimulation, implantation, stereotaxic lesions, and radiosurgery, among others. Most techniques are invasive or minimally invasive forms of surgical intervention and require immense precision to effectively modulate CNS circuitry. Focused ultrasound (FUS) is a relatively new, safe, non-invasive neurosurgical approach that has demonstrated efficacy in treating a range of functional neurological diseases. It can function reversibly, through mechanical stimulation causing circuitry changes, or irreversibly, through thermal ablation at low and high frequencies respectively. In preliminary studies, magnetic resonance imaging-guided high-intensity focused ultrasound (MRgHIFU) has been shown to have long-lasting treatment effects in several disease types. The technology has been approved by the FDA and internationally for a number of treatment-resistant neurological disorders and currently clinical trials are underway for several other neurological conditions. In this review, the authors discuss the potential applications and emerging role of MRgHIFU in functional neurosurgery in the coming years.

7.
Int J Hyperthermia ; 37(1): 1116-1130, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32990101

RESUMO

BACKGROUND: High intensity focused ultrasound (HIFU) is clinically accepted for the treatment of solid tumors but remains challenging in highly perfused tissue due to the heat sink effect. Endovascular liquid-core sonosensitizers have been previously suggested to enhance the thermal energy deposition at the focal area and to lower the near-/far-field heating. We are investigating the therapeutic potential of PFOB-FTAC micro-droplets in a perfused tissue-mimicking model and postmortem excised organs. METHOD: A custom-made in vitro perfused tissue-mimicking model, freshly excised pig kidneys (n = 3) and liver (n = 1) were perfused and subjected to focused ultrasound generated by an MR-compatible HIFU transducer. PFOB-FTAC sonosensitizers were injected in the perfusion fluid up to 0.235% v/v ratio. Targeting and on-line PRFS thermometry were performed on a 3 T MR scanner. Assessment of the fluid perfusion was performed with pulsed color Doppler in vitro and with dynamic contrast-enhanced (DCE)-MRI in excised organs. RESULTS: Our in vitro model of perfused tissue demonstrated re-usability. Sonosensitizer concentration and perfusion rate were tunable in situ. Differential heating under equivalent HIFU sonications demonstrated a dramatic improvement in the thermal deposition due to the sonosensitizers activity. Typically, the energy deposition was multiplied by a factor between 2.5 and 3 in perfused organs after the administration of micro-droplets, while DCE-MRI indicated an effective perfusion. CONCLUSION: The current PFOB-FTAC micro-droplet sonosensitizers provided a large and sustained enhancement of the HIFU thermal deposition at the focal area, suggesting solutions for less technological constraints, lower risk for the near-/far- field heating. We also report a suitable experimental model for other MRgHIFU studies.


Assuntos
Fluorocarbonos , Ablação por Ultrassom Focalizado de Alta Intensidade , Termometria , Animais , Hidrocarbonetos Bromados , Imageamento por Ressonância Magnética , Suínos
8.
Brain ; 143(9): 2664-2672, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32537631

RESUMO

Magnetic resonance guided high intensity focused ultrasound is a novel, non-invasive, image-guided procedure that is able to ablate intracranial tissue with submillimetre precision. It is currently FDA approved for essential tremor and tremor dominant Parkinson's disease. The aim of this update is to review the limitations of current landmark-based targeting techniques of the ventral intermediate nucleus and demonstrate the role of emerging imaging techniques that are relevant for both magnetic resonance guided high intensity focused ultrasound and deep brain stimulation. A significant limitation of standard MRI sequences is that the ventral intermediate nucleus, dentatorubrothalamic tract, and other deep brain nuclei cannot be clearly identified. This paper provides original, annotated images demarcating the ventral intermediate nucleus, dentatorubrothalamic tract, and other deep brain nuclei on advanced MRI sequences such as fast grey matter acquisition T1 inversion recovery, quantitative susceptibility mapping, susceptibility weighted imaging, and diffusion tensor imaging tractography. Additionally, the paper reviews clinical efficacy of targeting with these novel MRI techniques when compared to current established landmark-based targeting techniques. The paper has widespread applicability to both deep brain stimulation and magnetic resonance guided high intensity focused ultrasound.


Assuntos
Tremor Essencial/diagnóstico por imagem , Tremor Essencial/terapia , Tratamento por Ondas de Choque Extracorpóreas/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/terapia , Estimulação Encefálica Profunda/métodos , Globo Pálido/diagnóstico por imagem , Humanos
9.
J Magn Reson Imaging ; 48(4): 994-1001, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29504178

RESUMO

BACKGROUND: Diminished signal intensity of uterine fibroids in T2 -weighted images is routinely used as a qualitative marker of fibroid hypoperfusion. However, quantitative classification of fibroid perfusion with intravoxel incoherent motion (IVIM) model-based metrics is not yet clinically accepted. PURPOSE: To investigate the influence of T2 correction on the estimation of IVIM model parameters for characterizing uterine fibroid tissue. STUDY TYPE: Prospective. POPULATION: Fourteen women with 41 fibroids (12 Type I and 29 Type II, per Funaki classification) underwent diffusion-weighted imaging and T2 mapping. FIELD STRENGTH: Diffusion-weighted images (b values: 0, 20, 40, 60, 100, 200, 400, 600, 800, 1000 s/mm2 ) and T2 maps were obtained at 1.5T. ASSESSMENT: The effect of uterine fibroid T2 variation on IVIM model parameters (diffusion coefficient, perfusion coefficient, and perfusion volume fraction) were numerically modeled and experimentally evaluated without (D, D*, f) and with (Dc , D c * , fc ) T2 correction. The relationship of T2 with D and the T2 -corrected perfusion volume fraction (fc ) was also examined. STATISTICAL TEST: D-values and f-values estimated with and without T2 correction were compared by using a two-tailed Student's t-test. RESULTS: Type II fibroids had higher D and f than Type I fibroids, but the differences were not significant (Type I vs. Type II, D: 0.83 ± 0.20 vs. 0.80 ± 0.25 mm2 /s, P = 0.78; f: 23.64 ± 4.87% vs. 25.27 ± 7.46%, P = 0.49). For Type I and Type II fibroids, fc was lower than f, and fc of Type II fibroids was significantly higher than that of Type I fibroids (Type I vs. Type II, fc : 7.80 ± 1.88% vs. 11.82 ± 4.13%, P = 0.003). Both D and fc exponentially increased with the increase of fibroid T2 as functions: D c ( T 2 ) = - 1.52 × 10 - 3 ⋅ e - 3.42 T 2 290 + 1.84 × 10 - 3 and f c ( T 2 ) = - 0.2336 ⋅ e - 3.217 T 2 290 + 0.2269 , respectively. D asymptotically approached 1.79 × 10-3 mm2 /s, and fc approached 21.74%. DATA CONCLUSION: T2 correction is important when using IVIM-based models to characterize uterine fibroid tissue. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;48:994-1001.


Assuntos
Imagem de Difusão por Ressonância Magnética , Leiomioma/diagnóstico por imagem , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Movimento (Física) , Músculo Esquelético/diagnóstico por imagem , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes
10.
Neurosurg Focus ; 44(2): E12, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29385918

RESUMO

Stroke is one of the leading causes of death worldwide and a significant source of long-term morbidity. Unfortunately, a substantial number of stroke patients either are ineligible or do not significantly benefit from contemporary medical and interventional therapies. To address this void, investigators recently made technological advances to render transcranial MR-guided, high-intensity focused ultrasound (MRg-HIFU) sonolysis a potential therapeutic option for both acute ischemic stroke (AIS)-as an alternative for patients with emergent large-vessel occlusion (ELVO) who are ineligible for endovascular mechanical thrombectomy (EMT) or as salvage therapy for patients in whom EMT fails-and intracerebral hemorrhage (ICH)-as a neoadjuvant means of clot lysis prior to surgical evacuation. Herein, the authors review the technological principles behind MRg-HIFU sonolysis, its results in in vitro and in vivo stroke models, and its potential clinical applications. As a noninvasive transcranial technique that affords rapid clot lysis, MRg-HIFU thrombolysis may develop into a therapeutic option for patients with AIS or ICH. However, additional studies of transcranial MRg-HIFU are necessary to ascertain the merit of this treatment approach for thrombolysis in both AIS and ICH, as well as its technical limitations and risks.


Assuntos
Imageamento por Ressonância Magnética/métodos , Trombólise Mecânica/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Ultrassonografia de Intervenção/métodos , Animais , Humanos
11.
Neurosurg Focus ; 44(2): E16, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29385923

RESUMO

Since Lynn and colleagues first described the use of focused ultrasound (FUS) waves for intracranial ablation in 1942, many strides have been made toward the treatment of several brain pathologies using this novel technology. In the modern era of minimal invasiveness, high-intensity focused ultrasound (HIFU) promises therapeutic utility for multiple neurosurgical applications, including treatment of tumors, stroke, epilepsy, and functional disorders. Although the use of HIFU as a potential therapeutic modality in the brain has been under study for several decades, relatively few neuroscientists, neurologists, or even neurosurgeons are familiar with it. In this extensive review, the authors intend to shed light on the current use of HIFU in different neurosurgical avenues and its mechanism of action, as well as provide an update on the outcome of various trials and advances expected from various preclinical studies in the near future. Although the initial technical challenges have been overcome and the technology has been improved, only very few clinical trials have thus far been carried out. The number of clinical trials related to neurological disorders is expected to increase in the coming years, as this novel therapeutic device appears to have a substantial expansive potential. There is great opportunity to expand the use of HIFU across various medical and surgical disciplines for the treatment of different pathologies. As this technology gains recognition, it will open the door for further research opportunities and innovation.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/cirurgia , Procedimentos Neurocirúrgicos/métodos , Terapia por Ultrassom/métodos , Ultrassonografia de Intervenção/métodos , Previsões , Humanos , Doenças do Sistema Nervoso/diagnóstico por imagem , Doenças do Sistema Nervoso/cirurgia , Procedimentos Neurocirúrgicos/tendências , Terapia por Ultrassom/tendências , Ultrassonografia de Intervenção/tendências
12.
Neurosurg Focus ; 44(2): E11, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29385926

RESUMO

Currently, treatment of brain tumors is limited to resection, chemotherapy, and radiotherapy. Thermal ablation has been recently explored. High-intensity focused ultrasound (HIFU) is being explored as an alternative. Specifically, the authors propose delivering HIFU internally to the tumor with an MRI-guided robotic assistant (MRgRA). The advantage of the authors' interstitial device over external MRI-guided HIFU (MRgHIFU) is that it allows for conformal, precise ablation and concurrent tissue sampling. The authors describe their workflow for MRgRA HIFU delivery.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Imageamento por Ressonância Magnética/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Ultrassonografia de Intervenção/métodos , Humanos , Terapia a Laser/instrumentação , Terapia a Laser/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação
13.
J Ther Ultrasound ; 5: 17, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28652915

RESUMO

BACKGROUND: Dysfunction of the Sacroiliac Joint (SIJ) is one of the key sources of low back pain. For prolonged pain relief, some patients undergo fluoroscopic guided radio-frequency (RF) ablation of SIJ, during which a number of RF probes are inserted to create thermal lesions that disrupt the posterior sacral nerve supply. This procedure is minimally invasive, laborious, time-consuming and costly. To study if High Intensity Focused Ultrasound (HIFU) ablation is a feasible alternative approach to SIJ pain treatment, we performed experiments using HIFU to ablate SIJ in the swine model. METHODS: Three female Yorkshire swine (36, 35.2 and 34 kg) underwent bilateral Magnetic Resonance guided HIFU (MRgHIFU) ablation of the SIJs. Treatment assessment was performed using contrast-enhanced imaging, histopathology and evaluation of pain and changes in ambulation and gait. RESULTS: Contiguous lesions along the right and left SIJs were achieved in all animals. In one out of three animals, excessive heating of the muscle and skin tissue in the near-field resulted in unwanted muscle necrosis. No changes in animal behavior, ambulation or gait were detected. CONCLUSIONS: The initial experiments with MRgHIFU ablation of SIJs in sub-acute swine model show promise for this ablation modality as a non invasive and more precise alternative to the currently used fluoroscopically - guided RF ablations and injections.

14.
Ann Palliat Med ; 6(1): 36-54, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28209068

RESUMO

BACKGROUND: Pain is experienced by 50-75% of patients with bone metastases, representing a major source of morbidity amongst cancer patients. Magnetic resonance-guided high intensity focused ultrasound (MRgHIFU) is a new, non-invasive, outpatient treatment modality for painful bone metastases. The aim of this study was to analyze urinary cytokines/chemokines pattern after MRgHIFU for palliative treatment of painful bone metastases. The findings were compared to the cytokines/chemokines pattern post single 8 Gy fraction radiation from our previous study. METHODS: Urine samples were collected from patients with painful bone metastases 3 days before and 2 days after treatment with MRgHIFU. Each urine sample was tested for pro-inflammatory cytokines and anti-inflammatory cytokines. Patients received teaching on how to collect urine samples on their own. The Millipore Milliplex 42-Plex Cytokine/Chemokine Kit™ was used to measure urinary levels of a panel of cytokines/chemokines. RESULTS: Ten patients were enrolled for the study. The following 15 cytokines were above the level of detection (LOD) in at least 50% of patients at both pre MRgHIFU and post MRgHIFU: EGF, eotaxin, Fit-3 ligand, fractalkine, G-CSF, GRO, IFNα2, IL-1ra, IL-8, IP-10, MCP-1, PDGF-AA, RANTES, sIL-2Rα, and VEGF. Nine urinary cytokines significantly decreased post MRgHIFU, namely, eotaxin, GRO, IL-8, IL-13, IP-10, MCP-1, MIP-1ß, RANTES, and sIL-2Rα. In addition, there were significant differences between post MRgHIFU and post-8 Gy fraction radiation in most urinary cytokines. CONCLUSIONS: Nine urinary cytokines significantly reduced post-MRgHIFU in patients with painful bone metastases. The significance of cytokines/chemokines pattern for palliative treatment of painful bone metastases is still unknown.


Assuntos
Neoplasias Ósseas/cirurgia , Dor do Câncer/cirurgia , Quimiocinas/urina , Ablação por Ultrassom Focalizado de Alta Intensidade , Adulto , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Neoplasias Ósseas/urina , Dor do Câncer/etiologia , Citocinas/urina , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Cirurgia Assistida por Computador
15.
Magn Reson Med ; 78(5): 1911-1921, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28090656

RESUMO

PURPOSE: The therapy endpoint most commonly used in MR-guided high intensity focused ultrasound is the thermal dose. Although namely correlated with nonviable tissue, it does not account for changes in mechanical properties of tissue during ablation. This study presents a new acquisition sequence for multislice, subsecond and simultaneous imaging of tissue temperature and displacement during ablation. METHODS: A single-shot echo planar imaging sequence was implemented using a pair of motion-encoding gradients, with alternated polarities. A first ultrasound pulse was synchronized on the second lobe of the motion-encoding gradients and followed by continuous sonication to induce a local temperature increase in ex vivo muscle and in vivo on pig liver. Lastly, the method was evaluated in the brain of two volunteers to assess method's precision. RESULTS: For thermal doses higher than the lethal threshold, displacement amplitude was reduced by 21% and 28% at the focal point in muscle and liver, respectively. Displacement value remained nearly constant for nonlethal thermal doses values. The mean standard deviation of temperature and displacement in the brain of volunteers remained below 0.8 °C and 2.5 µm. CONCLUSION: This new fast imaging sequence provides real-time measurement of temperature distribution and displacement at the focus during HIFU ablation. Magn Reson Med 78:1911-1921, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Termografia/métodos , Animais , Temperatura Corporal , Encéfalo/diagnóstico por imagem , Humanos , Fígado/diagnóstico por imagem , Suínos
16.
J Ther Ultrasound ; 4: 30, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27980784

RESUMO

BACKGROUND: Non-invasive high-intensity focused ultrasound (HIFU) can be used to treat a variety of disorders, including those in the brain. However, the differences in acoustic properties between the skull and the surrounding soft tissue cause aberrations in the path of the ultrasonic beam, hindering or preventing treatment. METHODS: We present a method for correcting these aberrations that is fast, full-wave, and allows for corrections at multiple treatment locations. The method is simulation-based: an acoustic model is built based on high-resolution CT scans, and simulations are performed using the hybrid angular spectrum (HAS) method to determine the phases needed for correction. RESULTS: Computation of corrections for clinically applicable resolutions can be achieved in approximately 15 min. Experimental results with a plastic model designed to mimic the aberrations caused by the skull show that the method can recover 95 % of the peak pressure obtained using hydrophone-based time-reversal methods. Testing using an ex vivo human skull flap resulted in recovering up to 70 % of the peak pressure at the focus and 61 % when steering (representing, respectively, a 1.52- and 1.19-fold increase in the peak pressure over the uncorrected case). Additionally, combining the phase correction method with rapid HAS simulations allows evaluation of such treatment metrics as the effect of misregistration on resulting pressure levels. CONCLUSIONS: The method presented here is able to rapidly compute phases required to improve ultrasound focusing through the skull at multiple treatment locations. Combining phase correction with rapid simulation techniques allows for evaluation of various treatment metrics such as the effect of steering on pressure levels. Since the method computes 3D pressure patterns, it may also be suitable for predicting off-focus hot spots during treatments-a primary concern for transcranial HIFU. Additionally, the plastic-skull method presented here may be a useful tool in evaluating the effectiveness of phase correction methods.

17.
Int J Hyperthermia ; 31(4): 421-32, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25753370

RESUMO

OBJECTIVE: The aim of this paper is to quantitatively investigate the thermal effects generated by the pre-focal interactions of a HIFU beam with a rib cage, in the context of minimally invasive transcostal therapy of liver malignancies. MATERIALS AND METHODS: HIFU sonications were produced by a phased-array MR-compatible transducer on Turkey muscle placed on a sheep thoracic cage specimen. The thoracic wall was positioned in the pre-focal zone 3.5 to 6.5 cm below the focus. Thermal monitoring was simultaneously performed using fluoroptic sensors inserted into the medullar cavity of the ribs and high resolution MR-thermometry (voxel: 1 × 1 × 5 mm3, four multi-planar slices). RESULTS: MR-thermometry data indicated nearly isotropic distribution of the thermal energy at the ribs' surface. The temperature elevation at the focus was comparable with the pericostal temperature elevation around unprotected ribs, while being systematically inferior, by more than a factor of four on average, to the intra-medullar values. The spatial profiles of the pericostal and intra-medullar thermal build-up measurements could be smoothly connected using a Gaussian function. The dynamics of the post-sonication thermal relaxation as determined by fluoroptic measurements was demonstrated to be theoretically coherent with the experimental observations. CONCLUSION: The experimental findings motivate further efforts for the transfer towards clinical routine of effective rib-sparing strategies for hepatic HIFU.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/efeitos adversos , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética/métodos , Costelas/efeitos da radiação , Termografia/métodos , Animais , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Temperatura Alta , Imageamento por Ressonância Magnética/efeitos adversos , Ovinos , Termometria , Transdutores , Perus
18.
Magn Reson Med ; 72(4): 1087-95, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24243500

RESUMO

PURPOSE: Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges. METHODS: MR acquisition consisted of thermometry performed with segmented gradient-recalled echo echo-planar imaging, and a segment-based one-dimensional MR navigator parallel to the main axis of motion to track the organ motion. This tracking information was used in real-time for: (i) prospective motion correction of MR thermometry and (ii) HIFU focal point position lock-on target. Ex vivo experiments were performed on a sheep liver and a turkey pectoral muscle using a motion demonstrator, while in vivo experiments were conducted on two sheep liver. RESULTS: Prospective motion correction of MR thermometry yielded good signal-to-noise ratio (range, 25 to 35) and low geometric distortion due to the use of segmented EPI. HIFU focal point lock-on target yielded isotropic in-plane thermal build-up. The feasibility of in vivo intercostal liver treatment was demonstrated in sheep. CONCLUSION: The presented method demonstrated in moving phantoms and breathing sheep accurate motion-compensated MR thermometry and precise HIFU focal point lock-on target using only real-time pencil-beam navigator tracking information, making it applicable without any pretreatment data acquisition or organ motion modeling.


Assuntos
Artefatos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Vísceras/fisiologia , Vísceras/cirurgia , Abdome/fisiologia , Abdome/efeitos da radiação , Abdome/cirurgia , Animais , Temperatura Corporal/fisiologia , Temperatura Corporal/efeitos da radiação , Sistemas Computacionais , Ondas de Choque de Alta Energia , Aumento da Imagem/métodos , Técnicas In Vitro , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Cirurgia Assistida por Computador/métodos , Turquia , Vísceras/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA