Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Life (Basel) ; 13(2)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36836813

RESUMO

The aim of this study was to evaluate the influence of surface topography of gutta-percha (GP) cones and plasticized disks of GP on the initial adhesion of Enterococcus faecalis (E. faecalis). The GP cones (Tanari and Dentsply brands) were cut 3 mm from the apical portion and fixed on a glass slide. To make the disks, the cones were thermoplasticized in standardized molds. The specimens were divided into groups according to the shape of the GP and the presence or absence of the bacteria. For contamination, the strain of E. faecalis (ATCC 29212) was used. The surface topography was analyzed using an atomic force microscope (AFM). The surface, roughness, and waviness parameters were evaluated by the Kruskal-Wallis and Dunn test. The comparison between disks and cones showed significant differences, where the cones were rougher, with a higher value attributed to the Dentsply cone (DC group). The same was observed for the waviness. After contamination, there was greater bacterial accumulation in cones, especially in their valleys, but both the surface and the topography became more homogeneous and smoother, with no differences between disks and cones of both brands. The topographic surface of the GP, at the micro and nanoscale, influences the initial adhesion of E. faecalis, with a greater tendency for contamination in regions associated with the presence of roughness and waviness. In this context, plasticization of GP is indicated, as it reduces surface irregularities compared to cones, contributing to less retention of bacteria.

2.
J Dent ; 127: 104348, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36280006

RESUMO

OBJECTIVES: This in vitro study aimed to evaluate the effect of different times and concentrations of hydrofluoric acid etching on the surface of indirect restorative materials obtained from blocks used in CAD-CAM technology. METHODS: Specimens (4 mm × 4 mm × 0.8 mm) were obtained for each indirect restorative material: zirconia-reinforced lithium monosilicate ceramic (Celtra Duo), nanoceramic resin (Lava Ultimate), and polymer-infiltrated ceramic network material (Vita Enamic). The materials were submitted to etching with 5% or 10% hydrofluoric acid for 20, 40, 60, or 90 s. A control group for each material was evaluated without any surface treatment, totaling nine experimental groups for each material (n = 10). The specimens were evaluated for surface roughness (Ra and Rz), confocal optical microscopy, the contact angle (θ), surface free energy (γs), total free interaction energy (∆G) using a goniometer, and microshear bond strength to resin cement. Specimen images were obtained using scanning electron microscopy, confocal optical microscopy, and atomic force microscopy. Data on the surface roughness, the contact angle, surface free energy, total free interaction energy, and bond strength were subjected to two-way ANOVA and Tukey´s test (α=0.05). RESULTS: In general, Celtra Duo showed better results after etching with 10% hydrofluoric acid for 40 or 60 s. Lava Ultimate showed better performance after etching with 10% hydrofluoric acid for 20 or 40 s, whereas Vita Enamic showed better results after etching with 5% hydrofluoric acid for 90 s. CONCLUSION: Each material showed different characteristics after etching with hydrofluoric acid. Knowledge of the proper protocol for each material is essential to ensure improvements in the adhesion process and durability of indirect restorations. In general, Celtra Duo presented mechanical properties superior to those of Lava Ultimate and Vita Enamic. CLINICAL SIGNIFICANCE: Specific etching protocols must be recommended for each indirect material because longer exposure to hydrofluoric acid can jeopardize the surface, thus affecting the mechanical and bond strength properties.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Porcelana Dentária/química , Teste de Materiais , Propriedades de Superfície , Materiais Dentários/química , Cimentos de Resina/química , Cerâmica/química , Desenho Assistido por Computador
3.
Pesqui. bras. odontopediatria clín. integr ; 22: e210120, 2022. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1422283

RESUMO

Abstract Objective: To examine the cyclic fatigue resistance and surface topography of TruNatomy and ProTaper Gold nickel-titanium rotary files and evaluate the presence of alterations to surface topography following instrumentation in simulated curved canals. Material and Methods: Twenty-four nickel-titanium instruments, twelve each of TN and PTG file systems, were evaluated for cyclic fatigue resistance. The rotary files were rotated in a simulated root canal with standardized diameter, angle of curvature, and radius of curvature in a custom-made cyclic fatigue testing device until the instrument fracture occurred. The time to fracture for each instrument was recorded with a stopwatch; in seconds in each group. Fractured instruments were subjected to atomic force microscopy analysis measuring the average roughness and the root mean square values to investigate surface features of endodontic files. Mean values and standard deviation were calculated. Data were analyzed using the Mann-Whitney U test. Results: Time to fracture was marginally higher in PTG instruments than in the TN file systems. PTG files exhibited higher surface roughness when compared with TN files (p<0.05). Conclusion: TN file system had a higher cyclic fatigue resistance than PTG. Cyclic fatigue causing file breakage did affect the surface topography of the files. PTG files showed a higher surface porosity value than the TN files (AU).


Assuntos
Titânio/química , Microscopia de Força Atômica/instrumentação , Ligas Dentárias , Instrumentos Odontológicos , Endodontia , Propriedades de Superfície , Estatísticas não Paramétricas , Cavidade Pulpar , Testes de Dureza , Níquel/química
4.
Braz. oral res. (Online) ; 34: e005, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1055521

RESUMO

Abstract The purpose of this study was to evaluate the effect of ionizing radiation from high energy X-ray on fluoride release, surface roughness, flexural strength, and surface chemical composition of the materials. The study groups comprised five different restorative materials: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer, and Fuji IX GP. Twenty disk-shaped specimens (8x2 mm) for fluoride release and 20 bar-shaped specimens (25 x 2x 2 mm) for flexural strength were prepared from each material. Each material group was divided into two subgroups: irradiated (IR) and non-irradiated (Non-IR). The specimens from IR groups were irradiated with 1.8 Gy/day for 39 days (total IR = 70.2 Gy). The amount of fluoride released into deionized water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours and on days 2, 3, 7, 15, 21, 28, 35, and 39 (n = 10). The flexural strength was evaluated using the three-point bending test (n = 10). After the period of measurement of fluoride release, seven specimens (n = 7) from each group were randomly selected to evaluate surface roughness using AFM and one specimen was randomly selected for the SEM and EDS analyses. Data were analyzed with two-way ANOVA and Tukey tests (p = 0.05). The irradiation significantly increased fluoride release and surface roughness for Amalgomer CR and Zirconomer groups (p < 0.05). No significant change in flexural strength of the materials was observed after irradiation (p > 0.05). The ionizing radiation altered the amount of fluoride release and surface roughness of only Amalgomer CR and Zirconomer. The effect could be related to the chemical compositions of materials.


Assuntos
Apatitas/efeitos da radiação , Radiação Ionizante , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Resinas Compostas/efeitos da radiação , Fluoretos/química , Cimentos de Ionômeros de Vidro/efeitos da radiação , Apatitas/química , Valores de Referência , Espectrometria por Raios X , Propriedades de Superfície/efeitos da radiação , Fatores de Tempo , Zircônio/efeitos da radiação , Zircônio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância , Bis-Fenol A-Glicidil Metacrilato/química , Estatísticas não Paramétricas , Resinas Compostas/química , Resistência à Flexão , Cimentos de Ionômeros de Vidro/química
5.
Braz. oral res ; 27(6): 463-470, Nov-Dec/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-695990

RESUMO

The aim of this study was to assess the effect of different remineralizing agents on enamel microhardness (KHN) and surface topography after an erosive challenge. Forty-eight human enamel specimens (4 × 4 mm) were randomly assigned to 4 groups: control (no treatment), fluoride varnish, calcium nanophosphate paste and casein phosphopeptide-amorphous calcium phosphate paste (CPP-ACP). Both pastes were applied for 5 minutes, and fluoride varnish, for 24 h. Four daily erosive cycles of 5 minutes of immersion in a cola drink and 2 h in artificial saliva were conducted for 5 days. KHN readings were performed at baseline and after 5 days. The percentage of enamel hardness change (%KHN) was obtained after erosion. The surface topography was evaluated by atomic force microscopy (AFM). The data were tested using ANOVA, Tukey's and paired-T tests (p < 0.05). After an erosive challenge, there was no statistically significant difference between the control (96.8 ± 11.4 KHN / 72.4 ± 3.0 %KHN) and the varnish (91.7 ± 14.1 KHN / 73.4 ± 5.5 %KHN) groups. The nanophosphate group showed lower enamel hardness loss (187.2 ± 27.9 / 49.0 ± 7.9 %KHN), compared with the CPP-ACP group (141.8 ± 16.5 / 60.6 ± 4.0 %KHN), and both were statistically different from the varnish and the control groups. AFM images showed a rough surface for the control and the varnish groups, a non-homogeneous layer with globular irregularities for CPP-ACP, and a thick homogeneous layer for the nanophosphate group. None of the agents provided protection against the development of erosion; however, nanophosphate paste was able to reduce enamel surface softening after the erosive challenge.


Assuntos
Humanos , Fosfatos de Cálcio/uso terapêutico , Caseínas/uso terapêutico , Esmalte Dentário/efeitos dos fármacos , Erosão Dentária/prevenção & controle , Remineralização Dentária/métodos , Análise de Variância , Bebidas Gaseificadas , Esmalte Dentário/química , Testes de Dureza , Microscopia de Força Atômica , Nanopartículas , Distribuição Aleatória , Reprodutibilidade dos Testes , Saliva Artificial/química , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
6.
Rio de Janeiro; s.n; 2013. 75 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867230

RESUMO

O objetivo deste estudo foi avaliar a resistência de união a microtração de cimentos resinosos autoadesivos a cerâmicas de zircônia policristalina. Dezoito blocos cerâmicos de zircônia 3Y-TZP (9 LAVA™ e 9 LAVA™ Plus) foram jateados com partículas de 50 µm de Al2O3por 20 s com pressão de 28 psi a uma distância de 10 mm. Os blocos cerâmicos foram duplicados em resina composta (Point 4, Kerr) por moldagem com silicone. Os blocos de resina composta foram cimentados à superfície jateada da zircônia usando três diferentes cimentos resinosos autoadesivos: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). Após 24 h imersos em água destilada a 37oC, os blocos cimentados foram cortados em palitos para testes de microtração,com área da interface adesiva de 1 mm2 ± 0,2 mm, e tensionados até a fratura. Os resultados foram analisados pelo teste de análise de variância de dois fatores e pelo teste de comparações múltiplas LSD (α=0.05). As amostras fraturadas foram analisadas com microscopia eletrônica de varredura (MEV) e o modo de falha foi registrado. A topografia das superfícies cerâmicas antes e após o jateamento foi comparada por microscopia de força atômica (AFM). A resistência de união do cimento Speedcem à zircônia foi estatisticamente superior àquela reportada pelos cimentos RelyX Unicem 2 e SmartCem 2, independentemente da cerâmica usada (p<0,05). O fator cerâmica não teve influência estatística na resistência de união. A interação entre os dois fatores se mostrou significativa (p<0,05). O modo de fratura associado ao SmartCem 2 foi quase exclusivamente adesiva, enquanto oRelyX Unicem 2e o Speedcem exibiram um maior percentual de falhas mistas. Não foram observadas falhas coesivas. O AFM não revelou diferença no padrão de topografia de superfície entre as duas cerâmicas antes ou após o jateamento. Concluiu-se que o cimento Speedcem foi superior na adesão a cerâmicas de zircônia policristalina.


The aim of this study was to evaluate the microtensile bond strength of self-adhesive resin cements to polycrystalline zirconia. Eighteen 3Y-TZP ceramic blocks (9 LAVA™ and 9 LAVA™ Plus) were sandblasted with 50 µm Al2O3 powder for 20 s with a pressure of 28 psi at a working distance of 10 mm. The ceramic blocks were duplicated in composite resin (Point 4, Kerr) using a silicon mold. Composite blocks were bonded to sandblasted zirconia using different self-adhesive resin cements: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). After 24 h immersed in distilled water at 37oC the bonded specimens were cut into microtensile bond sticks of 1 mm2 ± 0,2 mminterface areaand loaded in tension until failure. Data were analyzed by two-way ANOVA and LSDtest for multiple comparisons (α=0.05). The fractured surfaces were observed using a scanning electron microscope (SEM) and the failure mode was recorded. Surface topography of the sandblasted and the as sintered zirconia materials were analyzed under an atomic force microscope (AFM).Bond strength of Speedcem cement to zirconia was significantly higher than that of RelyX Unicem 2 and SmartCem 2, irrespective of the ceramic used (p<0,05). Bond strength was not significantly influenced by the ceramic factor. Interactions were significant (p<0,05). The mode of failure of SmartCem 2 was almost exclusively adhesive, while RelyX Unicem 2 and Speedcem exhibited a good percentage of mixed fractures. No cohesive fractures were observed. AFM did not reveal differences in the topography pattern of the two ceramics before or after sandblasting. It was concluded that Speedcem presented superior adhesion to polycrystalline zirconia ceramics.


Assuntos
Cerâmica , Dentística Operatória , Teste de Materiais , Cimentos de Resina , Zircônio , Adesividade , Análise de Variância , Brasil , Cimentação , Colagem Dentária , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Propriedades de Superfície
7.
Rio de Janeiro; s.n; 2013. 75 p. ilus, tab.
Tese em Português | LILACS | ID: lil-755462

RESUMO

O objetivo deste estudo foi avaliar a resistência de união a microtração de cimentos resinosos autoadesivos a cerâmicas de zircônia policristalina. Dezoito blocos cerâmicos de zircônia 3Y-TZP (9 LAVA™ e 9 LAVA™ Plus) foram jateados com partículas de 50 µm de Al2O3por 20 s com pressão de 28 psi a uma distância de 10 mm. Os blocos cerâmicos foram duplicados em resina composta (Point 4, Kerr) por moldagem com silicone. Os blocos de resina composta foram cimentados à superfície jateada da zircônia usando três diferentes cimentos resinosos autoadesivos: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). Após 24 h imersos em água destilada a 37oC, os blocos cimentados foram cortados em palitos para testes de microtração,com área da interface adesiva de 1 mm2 ± 0,2 mm, e tensionados até a fratura. Os resultados foram analisados pelo teste de análise de variância de dois fatores e pelo teste de comparações múltiplas LSD (α=0.05). As amostras fraturadas foram analisadas com microscopia eletrônica de varredura (MEV) e o modo de falha foi registrado. A topografia das superfícies cerâmicas antes e após o jateamento foi comparada por microscopia de força atômica (AFM). A resistência de união do cimento Speedcem à zircônia foi estatisticamente superior àquela reportada pelos cimentos RelyX Unicem 2 e SmartCem 2, independentemente da cerâmica usada (p<0,05). O fator cerâmica não teve influência estatística na resistência de união. A interação entre os dois fatores se mostrou significativa (p<0,05). O modo de fratura associado ao SmartCem 2 foi quase exclusivamente adesiva, enquanto oRelyX Unicem 2e o Speedcem exibiram um maior percentual de falhas mistas. Não foram observadas falhas coesivas. O AFM não revelou diferença no padrão de topografia de superfície entre as duas cerâmicas antes ou após o jateamento. Concluiu-se que o cimento Speedcem foi superior na adesão a cerâmicas de zircônia policristalina...


The aim of this study was to evaluate the microtensile bond strength of self-adhesive resin cements to polycrystalline zirconia. Eighteen 3Y-TZP ceramic blocks (9 LAVA™ and 9 LAVA™ Plus) were sandblasted with 50 µm Al2O3 powder for 20 s with a pressure of 28 psi at a working distance of 10 mm. The ceramic blocks were duplicated in composite resin (Point 4, Kerr) using a silicon mold. Composite blocks were bonded to sandblasted zirconia using different self-adhesive resin cements: (1) RelyX Unicem 2 (3M ESPE); (2) SmartCem 2 (Dentsply); (3) Speedcem (Ivoclar Vivadent). After 24 h immersed in distilled water at 37oC the bonded specimens were cut into microtensile bond sticks of 1 mm2 ± 0,2 mminterface areaand loaded in tension until failure. Data were analyzed by two-way ANOVA and LSDtest for multiple comparisons (α=0.05). The fractured surfaces were observed using a scanning electron microscope (SEM) and the failure mode was recorded. Surface topography of the sandblasted and the as sintered zirconia materials were analyzed under an atomic force microscope (AFM).Bond strength of Speedcem cement to zirconia was significantly higher than that of RelyX Unicem 2 and SmartCem 2, irrespective of the ceramic used (p<0,05). Bond strength was not significantly influenced by the ceramic factor. Interactions were significant (p<0,05). The mode of failure of SmartCem 2 was almost exclusively adhesive, while RelyX Unicem 2 and Speedcem exhibited a good percentage of mixed fractures. No cohesive fractures were observed. AFM did not reveal differences in the topography pattern of the two ceramics before or after sandblasting. It was concluded that Speedcem presented superior adhesion to polycrystalline zirconia ceramics...


Assuntos
Cerâmica , Dentística Operatória , Teste de Materiais , Cimentos de Resina , Zircônio , Adesividade , Análise de Variância , Brasil , Cimentação , Colagem Dentária , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Propriedades de Superfície
8.
ROBRAC ; 20(52)abr. 2011. tab, ilus
Artigo em Português | LILACS | ID: lil-609176

RESUMO

Objetivo: Avaliar as alterações de rugosidade e morfologia superficial do esmalte e da resina composta após diferentes técnicas de clareamento dental. Material e método: incisivos bovinos íntegros foram selecionados, sendo que cavidades padronizadas foram confeccionadas na face vestibular, as quais foram restauradas com resina composta. Os dentes foram distribuídos em grupos, de acordo com o tratamento proposto: G1- clareamento com peróxido de carbamida (PC) 10%; G2 - clareamento com peróxido de hidrogênio (PH) a 38%; G3- clareamento com PH a 38% associado à foto-ativação com LED. Para G1, o agente clareador foi aplicado por 8 horas diárias durante 21 dias. Para G2 e G3, foram realizadas 3 sessões de clareamento, caracterizadas por 3 aplicações do gel clareador por 15 minutos, com intervalos de 7 dias entre as sessões, sendo que em G3 o gel clareador foi ativado com LED (470nm) por 6 minutos. As superfícies do esmalte e da resina composta foram avaliadas antes e após o procedimento clareador através de um rugosímetro e de um microscópio de força atômica. Resultados: Os resultados demonstraram diferença significante da rugosidade do esmalte antes e após o clareamento apenas para G1, em relação ao controle (Wilcoxon, p<0,05). Para a resina composta, nenhum dos grupos apresentou diferença estatística em relação ao controle (Mann-Whitney, p>0,05). Conclusão: O aumento da rugosidade do esmalte aconteceu apenas quando o clareamento foi realizado através da aplicação de um gel com 10% de PC. Nenhum dos procedimentos clareadores avaliados nesta pesquisa interferiram na rugosidade e morfologia da resina composta.


Objective: the aim of this study was to evaluate and compare the roughness and superficial morphology of enamel and a composite restorative resin after different bleaching techniques application. Material and Methods: Bovine incisors were selected and standardized cavities were prepared on the buccal surface, which were restored with composite resin. The teeth were distributed according to the following treatments: G1- bleaching with 10% carbamide peroxide (CP); G2 - bleaching with 38% hydrogen peroxide (HP); and G3 - bleaching with 38% of HP associated to light irradiation. For G1, the bleaching gel was applied for 8 hours daily during 21 days. For G2 and G3, 3 sessions were performed, consisting of 3 applications of 15 minutes each, with 7 days of intervals between the sessions. For G3, the LED (470nm) light was used to activate the bleaching agent for 6 minutes. The surface of enamel and composite resin were evaluated before and after the bleaching procedures using a roughness tester and an atomic force microscope. Results: The results showed significant differences in surface roughness of enamel after bleaching only for G1 (Wilcoxon, p<0.05). For composite resin, neither group showed a statistical difference compared to control (Mann-Whitney, p>0.05). Conclusion: It was concluded that the increase in the roughness of enamel occurred only after bleaching therapy using a gel with 10% of CP. The bleaching procedures evaluated in this investigation did not increase the roughness or cause changes in the superficial morphology of the composite resin.

9.
Araraquara; s.n; 2008. 112 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-590748

RESUMO

O estudo investigou os efeitos da radiação eletromagnética não ionizante emitidos pelos diodos LASER com comprimento de onda no espectro 688 ηm e 785 ηm, e diodo LED 635 ± 10 ηm, associados ao capeamento direto com hidróxido de cálcio em exposições pulpares mecânicas. Avaliou-se assim em dentes de macacos-prego a resposta pulpar baseado na morfologia das células pulpares, no processo inflamatório local, na formação da barreira mineralizada, e na organização do tecido pulpar nos diferentes grupos estudados. Discutiu-se também as diferentes fontes de emissão de radiação eletromagnética comparando os resultados obtidos de estimulação pulpar com os diodos LASER e LED, os quais apresentam energia coerente e não-coerente, respectivamente. Os resultado mostraram uma estimulação em todos os grupos irradiados com melhores resultados para o estímulo com LASER, quando comparado ao grupo tratado isoladamente com hidróxido de cálcio. Concluímos assim que a estimulação de energia eletromagnética LASER e LED associado ao capeamento pulpar direto com hidróxido de cálcio apresentou aceleração no processo de reparação tecidual. Porém, há necessidade de novos estudos com diferentes parâmetros de irradiação a fim de se obter protocolos cada vez mais eficientes para o estudo dos efeitos da luz sobre o processo de reparação pulpar.


The aim of this study was to compare the effects of non-ionizing electromagnetic radiation emitted by LASER diodes 688 ηm and 785 ηm, and LED diode 635 ± 10 ηm associated to direct pulp capping with calcium hydroxide in traumatic pulp exposures were investigated. Based on pulp cells morphology, on the local inflammatory process, on mineralized barrier formation and on pulp tissue organization, the pulp response in capuchin monkey teeth was evaluated in different groups. It was also discussed the different electromagnetic radiation emission sources effects comparing the obtained results of pulp stimulation with diodes LASER and LED, which present coherent and non-coherent energy respectively. Stimulation was observed in all irradiated groups, being the best results achieved with LASER stimulation, when compared to the group treated only with calcium hydroxide. Thus, it is concluded that the electromagnetic LASER and LED energy stimulation associated with calcium hydroxide direct pulp capping accelerated the tissue repair process. However, further studies with different stimulation parameters in order to obtain increasingly efficient protocols to study light effects on pulp repair are necessary.


Assuntos
Cebus , Capeamento da Polpa Dentária , Terapia com Luz de Baixa Intensidade , Microscopia de Força Atômica , Odontoblastos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA