Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 312
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(7): 101930, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39132008

RESUMO

Background: Patent foramen ovale (PFO) is seen in 25% of the general population but in up to 50% of patients ≤60 years old with cryptogenic strokes. Trials have shown that PFO closure vs medical therapy reduces the risk of future strokes. PFO closure may cause atrial fibrillation (AF), with prior trials reporting an incidence of 2% to 11.9%. However, the true incidence of AF after PFO closure is unknown due to limitations in prior studies for long-term monitoring. Methods: This is a retrospective observational study at a single center. Patients who underwent PFO closure and had an implantable loop recorder prior to PFO closure were included. The final review included 38 patients who had at least 2 months of implantable loop recorder data post-PFO closure. Results: Ten out of 38 (26%) patients developed AF post-PFO closure. The median time to the first episode of AF was 3.95 weeks, with 40% having their first AF episode after 3 months. Median duration of AF episodes was 1 hour. One hundred percent had spontaneous termination of AF. Of the AF patients, 70% were started on oral anticoagulant therapy. Conclusions: Our review shows a higher incidence of AF post-PFO closure as compared with most reported prior studies. We recommend larger prospective studies to explore the true incidence of AF post-PFO closure, its clinical impact, and subsequent stroke risk.

3.
Heliyon ; 10(11): e32105, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38882380

RESUMO

Background: Patent foramen ovale (PFO) is associated with migraine; however, the mechanism of PFO-associated migraine is not well known; additionally, percutaneous closure is controversial. This study aimed to investigate in situ thrombi within the PFO and explore the possible predictors of the effectiveness of PFO closure in migraineurs. Methods: This prospective cohort study included 48 asymptomatic patients and 92 migraineurs with PFO. Optical coherence tomography (OCT) was used to evaluate the PFO microstructure. Only migraineurs underwent percutaneous closure. Migraineurs were divided into two cohorts based on the presence of a thrombus within the PFO. The symptoms were assessed at the 12-month follow-up visit. Predictors were evaluated employing multivariate logistic regression and receiver operating characteristic curve analyses. Results: In situ thrombi within PFO were identified in 69 migraineurs and in two asymptomatic patients (76.7 % vs. 4.3 %; P < 0.001). Additionally, endocardial irregularity, discontinuity, low signal, and spasm were found in 59 (65.6 %), 15 (16.7 %), 13 (14.4 %), and six (6.7 %) patients, respectively, in the migraine group. In situ thrombus was associated with migraine risk (OR 49.03; 95%CI 8.52-282.18; P < 0.001). At the 12-month follow-up of the migraineur cohort, the primary endpoint, a 50 % reduction in migraine frequency after closure (with or without thrombus in PFO) was met (85.3 % vs. 25.0 %; P < 0.001). In situ thrombus was associated with migraine relief (OR 6.75; 95%CI 1.28-35.56; P = 0.024). Conclusions: In situ thrombus and abnormal endocardium within PFOs were common in migraineurs, and in situ thrombus was a risk factor for migraine. Percutaneous closure was more effective in migraineurs with thrombi within the PFO. OCT imaging improved the understanding of pathogenic PFOs and may be helpful in selecting suitable migraineurs for PFO closure.

4.
J Invasive Cardiol ; 2024 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-38814905

RESUMO

A 63-year-old man presented with delayed inferior ST-elevation myocardial infarction complicated with ventricular septal rupture (VSR). He developed cardiogenic shock and respiratory failure requiring intubation and Impella (Abiomed) support.

5.
J Am Coll Cardiol ; 83(19): 1886-1901, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38719369

RESUMO

Ventricular septal rupture remains a dreadful complication of acute myocardial infarction. Although less commonly observed than during the prethrombolytic era, the condition remains complex and is often associated with refractory cardiogenic shock and death. Corrective surgery, although superior to medical treatment, has been associated with high perioperative morbidity and mortality. Transcatheter closure techniques are less invasive to surgery and offer a valuable alternative, particularly in patients with cardiogenic shock. In these patients, percutaneous mechanical circulatory support represents a novel opportunity for immediate stabilization and preserved end-organ function. Multimodality imaging can identify favorable septal anatomy for the most appropriate type of repair. The heart team approach will define optimal timing for surgery vs percutaneous repair. Emerging concepts are proposed for a deferred treatment approach, including orthotropic heart transplantation in ideal candidates. Finally, for futile situations, palliative care experts and a medical ethics team will provide the best options for end-of-life clinical decision making.


Assuntos
Infarto do Miocárdio , Ruptura do Septo Ventricular , Humanos , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/terapia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos
6.
J Invasive Cardiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38718281

RESUMO

A 73-year-old man with a history of hypertension, hyperlipidemia, and obesity presented for cardiovascular evaluation. He was experiencing mild fatigue and dyspnea on exertion. Transthoracic echocardiogram (TTE) showed right ventricular dilation, which was otherwise unremarkable.

7.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742736

RESUMO

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Falha de Prótese , Humanos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ecocardiografia Transesofagiana , Masculino , Resultado do Tratamento , Feminino , Idoso , Reoperação
8.
J Invasive Cardiol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38787924

RESUMO

A 37-year-old man was referred to our medical center with a diagnosis of Eisenmenger syndrome due to an atrial septal defect (ASD). At admission he had central cyanosis, acrocyanosis, and progressive effort dyspnea; his symptoms improved during lying position.

9.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639140

RESUMO

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Assuntos
Cateterismo Periférico , Artéria Femoral , Técnicas Hemostáticas , Punções , Técnicas de Sutura , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Artéria Femoral/diagnóstico por imagem , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Cateterismo Periférico/efeitos adversos , Idoso , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Fatores de Risco , Fatores de Tempo , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Itália , Desenho de Equipamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Hemorragia/etiologia , Hemorragia/prevenção & controle
10.
Eur Heart J Case Rep ; 8(4): ytae170, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38654758

RESUMO

Background: Ventricular septal defect (VSD) is the most common type of congenital heart abnormality with perimembranous VSD (pmVSD) accounting for ∼70% of all VSD. Nowadays, transcatheter closure is the first choice for suitable pmVSD. However, there was no report about closing the large oval-shaped VSD percutaneously. Case summary: A 34-year-old male with known VSD was referred for transcatheter closure after failed attempts in other hospital. Patient had been diagnosed with VSD at a young age, but he was lost to follow-up. He presented with shortness of breath due to heart failure and pulmonary hypertension. The initial measurement of the defect was 6-7 mm by transthoracic echocardiography (TTE), transoesophageal echocardiography (TEE), and LV angiography. However, re-measurement using TEE and 3D echocardiography revealed that the VSD is oval with diameters of 18 mm × 6 mm. Initially, device No. 12/14 was used, but it was dislodged on two attempts. The operator then decided to upsize the device size to No. 16/18 that was successful. The patient's condition was good, and 6 months follow-up after the procedure showed good outcomes without any residual defect or arrhythmia. Discussion: In this study, we would like to highlight the rarity of large oval pmVSD that almost failed to be closed with the conventional measurement with echocardiography and fluoroscopy. Transoesophageal echocardiography especially 3D can be the new modality of choice that might be superior to fluoroscopy to decide the right device size in some cases such as oval-shaped pmVSD.

11.
J Invasive Cardiol ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662952

RESUMO

The authors present a case of percutaneous closure of an incomplete surgical left atrial appendage (LAA) ligation with a new device LAmbre (Lifetech ScientificCo Ltd).

12.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
13.
Int J Numer Method Biomed Eng ; 40(5): e3814, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38504482

RESUMO

Left atrial appendage occlusion (LAAO) is a percutaneous procedure to prevent thromboembolism in patients affected by atrial fibrillation. Despite its demonstrated efficacy, the LAA morphological complexity hinders the procedure, resulting in postprocedural drawbacks (device-related thrombus and peri-device leakage). Local anatomical features may cause difficulties in the device's positioning and affect the effectiveness of the device's implant. The current work proposes a detailed FE model of the LAAO useful to investigate implant scenarios and derive clinical indications. A high-fidelity model of the Watchman FLX device and simplified parametric conduits mimicking the zone of the LAA where the device is deployed were developed. Device-conduit interactions were evaluated by looking at clinical indicators such as device-wall gap, possible cause of leakage, and device protrusion. As expected, the positioning of the crimped device before the deployment was found to significantly affect the implant outcomes: clinician's choices can be improved if FE models are used to optimize the pre-operative planning. Remarkably, also the wall mechanical stiffness plays an important role. However, this parameter value is unknown for a specific LAA, a crucial point that must be correctly defined for developing an accurate FE model. Finally, numerical simulations outlined how the device's configuration on which the clinician relies to assess the implant success (i.e., the deployed configuration with the device still attached to the catheter) may differ from the actual final device's configuration, relevant for achieving a safe intervention.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Modelos Cardiovasculares , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Simulação por Computador , Análise de Elementos Finitos , Tromboembolia/prevenção & controle
14.
Cardiol Young ; 34(4): 705-712, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329109

RESUMO

INTRODUCTION: The optimal management of a patent ductus arteriosus in a population of preterm infants is controversial. Traditionally, when the patent ductus arteriosus does not close either with conservative treatment or in response to pharmacological therapy, the only option is surgical closure. However, transcatheter occlusion might provide a therapeutic alternative. METHODS: We searched PubMed, Embase, and Cochrane databases for non-randomised and randomised controlled trials that compared transcatheter percutaneous closure of patent ductus arteriosus with surgical ligation in low-birth-weight preterm infants (<2,500 g). A random-effects model was used for outcomes with high heterogeneity. RESULTS: We included twelve studies comprising 4,668 low-birth-weight preterm infants, of whom 966 (20.7%) were in the transcatheter percutaneous closure group, and 3,702 (79.3%) patients were included in the surgical group. All-cause mortality (OR 0.28; 95% confidence interval 0.18-0.423; p < 0.00001; I2 = 0%) and haemodynamic instability (OR 0.10; 95% confidence interval 0.05-0.21; p < 0.001; I2 = 14%) were significantly lower in the transcatheter percutaneous closure group. There was no significant difference between transcatheter and surgical patent ductus arteriosus closure for the outcomes of bronchopulmonary dysplasia (0.93; 95% confidence interval 0.46-1.87; p = 0.83; I2 = 0%) and major complications (OR 0.76; 95% confidence interval 0.34-1.69; p = 0.51; I2 = 43%). CONCLUSION: These findings suggest that transcatheter patent ductus arteriosus closure in preterm infants under 2,500 g is a safe and effective alternative to surgical treatment. There was a substantial reduction in all-cause mortality and haemodynamic instability with transcatheter intervention compared to surgical closure.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Recém-Nascido de Baixo Peso , Recém-Nascido Prematuro , Permeabilidade do Canal Arterial/cirurgia , Humanos , Recém-Nascido , Cateterismo Cardíaco/métodos , Ligadura/métodos , Procedimentos Cirúrgicos Cardíacos/métodos
15.
J Invasive Cardiol ; 36(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38422531

RESUMO

A 78-year-old male patient with a history of coronary artery disease (he had undergone coronary artery bypass surgery 4 years ago), heart failure with mildly reduced ejection fraction, diabetes mellitus, and transient ischemic attack presented to the emergency department with complaints of dyspnea (New York Heart Association Class 4) despite the optimal medical therapy.


Assuntos
Falso Aneurisma , Cateterismo Cardíaco , Ventrículos do Coração , Humanos , Masculino , Idoso , Falso Aneurisma/diagnóstico , Falso Aneurisma/cirurgia , Falso Aneurisma/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Cateterismo Cardíaco/métodos , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia
16.
J Invasive Cardiol ; 36(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38412438

RESUMO

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Assuntos
Forame Oval Patente , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Tromboembolia , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Forame Oval Patente/diagnóstico , Forame Oval Patente/cirurgia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Dispositivo para Oclusão Septal/efeitos adversos , Tromboembolia/etiologia , Cateterismo Cardíaco/métodos
17.
Eur Heart J Case Rep ; 8(2): ytae045, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38332924

RESUMO

Background: Ventricular septal defect (VSD) is an unusual complication of transcatheter aortic valve implantation (TAVI). The risk factors are not well understood but may include oversizing, calcification amount and location, left-ventricular chamber morphology, and valve-in-valve (ViV) procedures. Percutaneous treatment is challenging but is usually the preferred option. Case summary: An 80-year-old woman with two previous surgical aortic valve replacements was admitted to our Cardiology Department for decompensated heart failure. New bioprosthesis degeneration (19 mm Mitroflow™, Sorin Group, Canada) was observed with severe intraprosthetic aortic regurgitation. After evaluation, the heart team chose to perform ViV TAVI. Because of the high risk of coronary obstruction, chimney stenting of both coronary arteries was performed. A 23 mm self-expandable Navitor™ valve (Abbott, IL, USA) was implanted, but the Mitroflow™ valve had to be cracked to minimize the persistent high gradient. During valve fracture, the non-compliant balloon broke and a small iatrogenic VSD appeared. However, the patient remained stable, so conservative management was selected. During follow-up, she developed severe haemolytic anaemia and heart failure; therefore, percutaneous closure of the iatrogenic VSD was performed twice, which was a difficult challenge. Discussion: A viable alternative to redo surgery is ViV TAVI. Risks include higher rates of prosthesis-patient mismatch and coronary obstruction. Occasionally, bioprosthetic valve fracture is required, particularly in small bioprostheses, to achieve low gradients. Anecdotally, fracture has led to annular rupture and VSD. Most VSDs are small and without clinical or haemodynamic repercussions; however, in symptomatic cases, percutaneous closure is a viable alternative to surgery.

19.
Int J Cardiol ; 401: 131820, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38307419

RESUMO

BACKGROUND: Post-myocardial infarction ventricular septal rupture (VSR) is a rare and severe complication of myocardial infarction. To find early mortality (<30 days) risk factors of device VSR closure and to evaluate its medium-term outcome. METHODS: Multicenter retrospective analysis on all 46 consecutive patients with percutaneous (n = 43) or hybrid (n = 3) VSR closure in 2000-2020 with various nitinol wire mesh occluders. Medical records, hemodynamic data, procedure results, short- and mid-term follow-up were analyzed (4.8 ± 3.7 years, range: 0.1-15, available in 61.7% of patients). Of the patients, 34.8% underwent VSR closure in acute phase (<21 days after VSR occurrence), 17.4% underwent device closure due to significant residual shunt after previous VSR surgery. RESULTS: Success rate was 78.3%. More than moderate residual shunt, major complications, and early surgical reintervention affected 18.9%, 15.2% (including 2 intra-procedural deaths), and 21.7% of patients, respectively. Early mortality was 26.1% (13.9% in successful vs. 70% in unsuccessful closure; p < 0.001). Older age, need for intra-aortic balloon counterpulsation, severe complications, and procedural failure were identified as risk factors for early mortality. Among patients who survived the early period, the 5-year survival rate was 57.1%. NYHA class improved in 88.2% patients at the latest follow-up. CONCLUSIONS: Procedure of VSR device closure demonstrates an acceptable technical success rate; however, the incidence of severe complications and early mortality is notably high. Older patients in poor hemodynamic condition and those with unsuccessful occluder deployment are particularly at a higher risk of a fatal outcome. The prognosis after early survival is promising.


Assuntos
Infarto do Miocárdio , Ruptura do Septo Ventricular , Humanos , Ruptura do Septo Ventricular/diagnóstico , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia , Estudos Retrospectivos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/complicações , Fatores de Risco , Prognóstico , Resultado do Tratamento
20.
Ann Cardiol Angeiol (Paris) ; 73(2): 101718, 2024 Apr.
Artigo em Francês | MEDLINE | ID: mdl-38262253

RESUMO

INTRODUCTION: Post-infarction ventricular septal defect (PIVSD) is one of the most serious mechanical complications of acute myocardial infarction (AMI). Over the last decade, percutaneous closure is increasingly undertaken, with results similar to cardiac surgery. We present a case of ST-elevated anterior AMI, complicated by apical PIVSD successfully treated with transcatheter closure. CASE REPORT: An 83-year-old man was hospitalized for chest pain occurred 18 hours before, during the night time. He was an active smoker. Clinical examination revealed normal heart sounds and pulmonary bibasilar crackles. ST-segment elevation with deep T waves inversion in anterior leads were detected on the electrocardiogram. A mildly-reduced ejection fraction (40%) was found by transthoracic echocardiogram. The patient underwent emergency coronary angiography, which revealed a subocclusive stenosis of the mid left anterior descending artery with a TIMI 2 flow, treated by balloon angioplasty and drug-eluting stent. Four days after revascularization, the patient developed an acute deterioration with signs of decompensated heart failure and a new holosystolic murmur with large irradiation. Inotropic agents' administration was required to maintain a precarious hemodynamic condition. A bedside Echo revealed an apical VSD, measuring 15 × 10 mm, with left-to-right shunting, and pulmonary hypertension. The patient was scheduled for transcatheter PIVSD closure. The procedure was performed under fluoroscopic guide. Two vascular access sites were placed, femoral arterial and right internal jugular vein. Through the right internal jugular vein, a 24-mm Amplatzer atrial septal occluder on a 9 French Amplatzer TREVISIO™ intravascular delivery system was advanced via right ventricle into the PIVSD. Contrast fluoroscopy was used to assess apposition and the degree of shunt reduction before release. Echocardiographic evaluation performed 48 hours later confirmed a correct apposition of the device with insignificant residual shunt. At 6 months follow-up, he was asymptomatic, with unchanged prosthetic findings. CONCLUSION: Percutaneous closure has been emerged as a valid cost-effective alternative to surgery and should be advised. However, debate remains on the optimal preprocedural optimization, timing of repair and modality of treatment.


Assuntos
Infarto Miocárdico de Parede Anterior , Procedimentos Cirúrgicos Cardíacos , Stents Farmacológicos , Comunicação Interventricular , Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Dispositivo para Oclusão Septal , Masculino , Humanos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Cateterismo Cardíaco/métodos , Infarto do Miocárdio/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Infarto Miocárdico de Parede Anterior/complicações , Comunicação Interventricular/complicações , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA