1.
Radiol Case Rep ; 19(11): 4721-4724, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39228939

RESUMO

A 77-year-old woman presented to our hospital with a 2-week history of fever, headache, and induration along the bilateral superficial temporal arteries (STAs). The color Doppler ultrasonography of the STA showed a hypoechoic mural thickening surrounding a residual color flow. A contrast-enhanced photon-counting detector (PCD) CT demonstrated mural thickening and stenosis of the bilateral STAs. The patient underwent a biopsy of the right STA. Histopathological findings were consistent with giant cell arteritis (GCA). The patient's symptoms were temporarily relieved after initiation of steroid treatment, but jaw claudication occurred 2 months later. Contrast-enhanced CT showed improved vascular abnormalities of the STAs but new mural thickening and stenosis of the bilateral maxillary artery. Due to its higher resolution, image contrast, and lower noise, PCD-CT may have great potential in detecting, diagnosing, and monitoring GCA.

2.
Med Phys ; 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39235343

RESUMO

BACKGROUND: The first commercially available photon-counting-detector CT (PCD-CT) has been introduced for clinical use. However, its spectral performance on single- and dual-contrast imaging tasks has not been comprehensively assessed. PURPOSE: To evaluate the spectral imaging performance of a clinical PCD-CT system for single-contrast material [iodine (I) or gadolinium (Gd)] and dual-contrast materials (I and Gd) in comparison with a dual-source dual-energy CT (DS-DECT). METHODS: Iodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso-shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD-CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS-DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two-material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three-material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region-of-interests placed on the contrast samples. Root-mean-square-error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices. RESULTS: For all material decomposition tasks on the DS-DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS-DECT and PCD-CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD-CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD-CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD-CT generating higher RMSE values for gadolinium concentration compared to all DS-DECT and PCD-CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD-CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS-DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality. CONCLUSION: Optimal tube voltage for material decomposition on the clinical PCD-CT is task-dependent but inferior to DS-DECT using 70/Sn150 kV or 80/Sn150 kV in two-material decomposition for single-contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual-contrast imaging yields substantially higher RMSE for both imaging platforms.

3.
Eur J Radiol ; 181: 111717, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39241304

RESUMO

PURPOSE: Accurate measurements of trabecular bone microarchitecture are required for a proper assessment of bone fragility. Photon-counting detector CT (PCD-CT) has different technical properties than conventional CT, resulting in higher resolution and thereby potentially enabling in-vivo measurement of trabecular microarchitecture. The purpose of this study was to quantify trabecular bone microarchitectural parameters with PCD-CT at varying radiation doses and compare this to µCT as gold standard. METHOD: Both distal radii, distal tibiae, femoral heads, and two vertebrae were dissected from one human. All specimens were scanned ex-vivo on a PCD-CT system (slice increment 0.1 mm; pixel size 0.1042-0.127 mm) and a µCT system (isotropic voxel size 49-68.4 µm). The radiation doses of the PCD-CT scans were varied from 2.5 to 120 mGy based on the volume CT dose index (CTDIvol32). For the PCD-CT scans, contrast-to-noise ratio and trabecular sharpness were calculated and compared between radiation doses. µCT and PCD-CT scans were registered. The trabecular bone was then segmented from all PCD-CT and µCT scans and split into cubes with 6-mm edge length. For each cube, bone volume over total volume, trabecular thickness, trabecular number, and trabecular heterogeneity were calculated and compared between corresponding PCD-CT and µCT cubes. RESULTS: With increasing dose, contrast-to-noise ratio and trabecular sharpness values increased for the PCD-CT images. Already at the lowest dose, high correlations between the trabecular microarchitectural parameters between µCT and PCD-CT were found (R2 = 0.55-0.95), which improved with increasing radiation dose (R2 = 0.76-0.96 at 20 mGy). CONCLUSIONS: PCD-CT can be used to quantify trabecular bone microarchitecture, with accuracy comparable to µCT and at clinically relevant radiation doses.

4.
Eur Radiol Exp ; 8(1): 89, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090380

RESUMO

BACKGROUND: Lower extremity peripheral artery disease frequently presents with calcifications which reduces the accuracy of computed tomography (CT) angiography, especially below-the-knee. Photon-counting detector (PCD)-CT offers improved spatial resolution and less calcium blooming. We aimed to identify the optimal reconstruction parameters for PCD-CT angiography of the lower legs. METHODS: Tubes with different diameters (1-5 mm) were filled with different iodine concentrations and scanned in a water container. Images were reconstructed with 0.4 mm isotropic resolution using a quantitative kernel at all available sharpness levels (Qr36 to Qr76) and using different levels of quantum iterative reconstruction (QIR-2-4). Noise and image sharpness were determined for all reconstructions. Additionally, CT angiograms of 20 patients, reconstructed with a medium (Qr44), sharp (Qr60), and ultrasharp (Qr72) kernel at QIR-2-4, were evaluated by three readers assessing noise, delineation of plaques and vessel walls, and overall quality. RESULTS: In the phantom study, increased kernel sharpness led to higher image noise (e.g., 16, 38, 77 HU for Qr44, Qr60, Qr72, and QIR-3). Image sharpness increased with increasing kernel sharpness, reaching a plateau at the medium-high level 60. Higher QIR levels decreased image noise (e.g., 51, 38, 25 HU at QIR-2-4 and Qr60) without reducing vessel sharpness. The qualitative in vivo results confirmed these findings: the sharp kernel (Qr60) with the highest QIR yielded the best overall quality. CONCLUSION: The combination of a sharpness level optimized reconstruction kernel (Qr60) and the highest QIR level yield the best image quality for PCD-CT angiography of the lower legs when reconstructed at 0.4-mm resolution. RELEVANCE STATEMENT: Using high-resolution PCD-CT angiography with optimized reconstruction parameters might improve diagnostic accuracy and confidence in peripheral artery disease of the lower legs. KEY POINTS: Effective exploitation of the potential of PCD-CT angiography requires optimized reconstruction parameters. Too soft or too sharp reconstruction kernels reduce image quality. The highest level of quantum iterative reconstruction provides the best image quality.


Assuntos
Angiografia por Tomografia Computadorizada , Imagens de Fantasmas , Fótons , Angiografia por Tomografia Computadorizada/métodos , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Masculino , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Feminino , Idoso , Pessoa de Meia-Idade
5.
Artigo em Inglês | MEDLINE | ID: mdl-39110320

RESUMO

To validate the accuracy of coronary artery calcium score (CACS) using photon-counting detector (PCD) CT under various scanning settings and explore the optimized scanning settings considering both the accuracy and the radiation dose. A CACS phantom containing six hollow cylindrical hydroxyapatite calcifications of two sizes with three densities and 12 patients underwent CACS scans. For PCD-CT, two scanning modes (sequence and flash [high-pitch spiral mode]) and five tube voltages (90kV, 120kV, 140kV, Sn100kV, and Sn140kV) at different image quality (IQ) levels were set for phantom, and patients were scanned with 120kV at IQ19 using flash mode. All acquisitions from PCD-CT were reconstructed at 70keV. Acquisitions in sequence mode at 120kV on an energy-integrating detector CT (EID-CT) was used as the reference. Agatston, mass, and volume scores were calculated. The CACS from PCD-CT exhibited excellent agreements with the reference (all intraclass correlation coefficient [ICC] > 0.99). The root mean square error (RMSE) between the Agatston score acquired from PCD-CT and the reference (5.4-11.5) was small. A radiation dose reduction (16-75%) from PCD-CT compared with the reference was obtained in all protocols using flash mode, albeit with IQ20 only at sequence mode (22-44%). For the patients, ICC ( all ICC > 0.98) and Bland-Altman analysis of CACS all showed high agreements between PCD-CT and the reference, without reclassifying CACS categories(P = 0.317). PCD-CT yields repeatable and accurate CACS across diverse scanning protocols according to our pilot study. Sn100kV, 90kV, and 120kV using flash mode at IQ20 are recommended for clinical applications considering both accuracy and radiation dose.

6.
Acad Radiol ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39112295

RESUMO

RATIONALE AND OBJECTIVES: To validate the image quality of low-dose ultra-high-resolution (UHR) scanning mode of photon-counting detector CT (PCD-CT) for visceral artery computed tomography angiography (CTA). MATERIAL AND METHODS: We prospectively enrolled 57 patients each in the full dose (FD) and low-dose (LD) protocols, respectively, to undergo abdominal CT scans using the UHR mode on a PCD-CT system (NAEOTOM Alpha), between April 2023 and September 2023. Both the FD data and LD data were then reconstructed into two series of images: (a) 0.2 mm slice thickness, reconstruction kernel Bv48, quantum iterative reconstruction (QIR) 4; (b)1 mm slice thickness, Bv40, QIR 3. The signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) of seven arteries were objectively measured. The image noise, vessel sharpness, overall quality, and visibility of nine arteries were subjectively assessed by three radiologists. RESULTS: The SNRs and CNRs of 0.2 mm reconstruction set was inferior to that of 1 mm reconstruction set (p < 0.001 for all the arteries and noise), however, the image quality of 0.2 mm reconstruction set was higher than that of 1 mm reconstruction set in qualitative evaluation especially for tiny arteries in Volume-rendered (VR) image (p < 0.001). The SNRs and CNRs were not significantly higher for FD group than LD group on the same slice thickness except for SNRs of common hepatic artery, splenic artery and bilateral renal arteries in 0.2 mm reconstruction set. In the comparison on image quality between normal weight and overweight patients within the same reconstruction set, the results showed that low-dose scan did not significantly impact the image quality in overweight patients. The ratings of visibility of nine visceral arteries were not significantly different among FD and LD at the same thickness reconstruction set except for superior mesenteric artery (p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in axial image; p = 0.002 and 0.007 for 0.2 mm and 1 mm reconstruction set in coronal image, respectively) and left gastric artery (p = 0.002 and p < 0.001 for 0.2 mm and 1 mm reconstruction set in VR image, respectively). CONCLUSION: The low-dose UHR scanning mode of PCD-CT has proven to be adequate for the clinical evaluation of visceral arteries. Utilizing a reconstruction with a slice thickness of 0.2 mm could enhance arterial depiction, particularly for small vessels.

7.
Clin Imaging ; 113: 110235, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39059085

RESUMO

OBJECTIVE: This study aims to assess the efficacy of polyenergetic reconstruction methods in reducing streak artifacts caused by dual source imaging in Photon Counting Detector Computed Tomography (PCD-CT) imaging, thereby improving image quality and diagnostic accuracy. METHODS: A retrospective cohort study was conducted, involving 50 patients who underwent chest Computed Tomography Angiography with PCD-CT, focusing on those with streak artifacts. Quantitative and qualitative analyses were performed on images reconstructed using monoenergetic and polyenergetic techniques. Quantitative evaluations measured the attenuation of tracheal air density in regions affected by streak artifacts, while qualitative assessments employed a modified Likert scale to rate image quality. Statistical analyses included Wilcoxon's signed-rank tests and Spearman's correlation, alongside assessments of inter-rater reliability. RESULTS: There was significantly lower attenuation of tracheal air density on the polyenergetic reconstructions (Median - 1010 ± 62 HU vs -930 ± 110 HU; P < 0.001), and significantly decreased variation on the polyenergetic reconstructions (Median 65.2 ± 79.5 HU vs 38.8 ± 33.9 HU; P < 0.001). The median modified-Likert scale were significantly better for the polyenergetic reconstructions (median modified-Likert 4 ± 0.5 vs 2.5 ± 1; P < 0.001). The inter-rater agreement was substantial and not significantly different between reconstructions (Gwet's ACPolyenergetic = 0.78 vs Gwet's ACVMI = 0.775). CONCLUSION: Polyenergetic reconstruction significantly mitigates streak artifacts in PCD-CT imaging, enhancing quantitative and qualitative image quality. This advancement addresses a known limitation of current PCD-CT reconstruction techniques, offering a promising approach to improving diagnostic reliability and accuracy in clinical practice. We demonstrate that future software implementations can resolve this artifact.


Assuntos
Artefatos , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Reprodutibilidade dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Adulto , Tomografia Computadorizada por Raios X/métodos , Radiografia Torácica/métodos
8.
Radiol Cardiothorac Imaging ; 6(4): e230328, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39023373

RESUMO

Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Doença da Artéria Coronariana , Imagens de Fantasmas , Placa Aterosclerótica , Humanos , Masculino , Feminino , Estudos Prospectivos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Idoso , Fótons , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Coronária/métodos , Meios de Contraste
9.
Abdom Radiol (NY) ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39052057

RESUMO

Photon counting CT was recently introduced into clinical practice [Rajendran K, Petersilka M, Henning A, Shanblatt ER, Schmidt B, Flohr TG, Ferrero A, Baffour F, Diehn FE, Yu L, Rajiah P, Fletcher JG, Leng S, McCollough CH. First Clinical Photon-counting Detector CT System: Technical Evaluation. Radiology 2022;303(1):130-138. doi: https://doi.org/10.1148/radiol.212579 ]. Photon counting detectors (PCD) afford better spatial resolution, radiation dose efficiency, and iodine contrast-to-noise than EID-CT [Leng S, Bruesewitz M, Tao S, Rajendran K, Halaweish AF, Campeau NG, Fletcher JG, McCollough CH. Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology. Radiographics 2019;39(3):729-743. doi: https://doi.org/10.1148/rg.2019180115 ); (Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-mum Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol 2018;53(11):655-662. doi: https://doi.org/10.1097/RLI.0000000000000488 )(Booij R, van der Werf NR, Dijkshoorn ML, van der Lugt A, van Straten M. Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data. Diagnostics (Basel) 2022;12(6). doi: https://doi.org/10.3390/diagnostics12061467 ); (Sawall S, Klein L, Amato C, Wehrse E, Dorn S, Maier J, Heinze S, Schlemmer HP, Ziener CH, Uhrig M, Kachelriess M. Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT. Eur J Radiol 2020;126:108909. doi: https://doi.org/10.1016/j.ejrad.2020.108909 ] while also maintaining multienergy CT (MECT) capabilities[Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020;79:126-136. doi: https://doi.org/10.1016/j.ejmp.2020.10.030 ]. This article will review the clinical adoption of PCD-CT including protocol development, clinical applications, clinical integration and workflow considerations. Protocol development is institution specific and involves collaborative decision-making among radiologists, physicists, and technologists. Key PCD clinical applications include radiation exposure reduction, intravenous contrast volume reduction, and improved lesion conspicuity. Patients who would most benefit from these improvements may preferentially be scanned with PCD CT. With numerous available reconstructions, radiologists should be strategic in the series sent to PACS for interpretation and routinely sending spectral series to PACS can facilitate integration with clinical workflow. The Society of Abdominal Radiology PCD Emerging Technology Commission endorsed this article.

10.
Eur J Radiol ; 177: 111545, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38878499

RESUMO

OBJECTIVE: Fat deposition is an important marker of many metabolic diseases. As a noninvasive and convenient examination method, CT has been widely used for fat quantification. With the clinical application of photon-counting detector (PCD)-CT, we aimed to investigate the accuracy, stability, and dose level of PCD-CT using various scan settings for fat quantification. MATERIALS AND METHODS: Eleven agar-based lipid-containing phantoms (vials with different fat fractions [FFs]; range: 0 %-100 %) were scanned using PCD-CT. Three scanning types (sequence scan, regular spiral scan with a pitch of 0.8, and high-pitch spiral scan with a pitch of 3.2), four tube voltages (90, 120, 140, and 100 kV with a tin filter), and three image quality (IQ) levels (IQ levels of 20, 40, and 80) were alternated, and each scan setting was used twice. For each scan, a 70-keV image was generated using the same reconstruction parameters. A regular spiral scan at 120 kV with IQ80 was used to transfer the CT numbers of all scans to the FF. Intraclass correlation coefficient (ICC) and Bland-Altman analysis were implemented for accuracy and agreement evaluation, and group differences were compared using analysis of variance. RESULTS: Excellent agreement and accuracy of FF derived by PCD-CT with all scan settings was demonstrated by high ICCs (>0.9; range: 0.929-0.998, p < 0.017) and low bias (<5% range: -2.9 %-5%). The root mean square error (RMSE) between the PCD-CT-acquired FF and the reference standard ranged from 1.0 % to 5.0 %, among which the high-pitch scan at 120 kV with IQ20 accounted for the lowest RMSE (1.0 %). The spiral scan at 120 kV with IQ20 and IQ80 yielded the lowest bias (mean value: 1.19 % and 1.23 %, respectively). CONCLUSION: Fat quantification using PCD-CT reconstructed at 70 keV was accurate and stable under various scan settings. PCD-CT has great potential for fat quantification using ultralow radiation doses.


Assuntos
Tecido Adiposo , Imagens de Fantasmas , Fótons , Tecido Adiposo/diagnóstico por imagem , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Humanos
11.
Eur Radiol ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935123

RESUMO

OBJECTIVES: To assess the accuracy of a synthetic hematocrit derived from virtual non-contrast (VNC) and virtual non-iodine images (VNI) for myocardial extracellular volume (ECV) computation with photon-counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: Consecutive patients undergoing PCD-CT including a coronary CT angiography (CCTA) and a late enhancement (LE) scan and having a blood hematocrit were retrospectively included. In the first 75 patients (derivation cohort), CCTA and LE scans were reconstructed as VNI at 60, 70, and 80 keV and as VNC with quantum iterative reconstruction (QIR) strengths 2, 3, and 4. Blood pool attenuation (BPmean) was correlated to blood hematocrit. In the next 50 patients (validation cohort), synthetic hematocrit was calculated using BPmean. Myocardial ECV was computed using the synthetic hematocrit and compared with the ECV using the blood hematocrit as a reference. RESULTS: In the derivation cohort (49 men, mean age 79 ± 8 years), a correlation between BPmean and blood hematocrit ranged from poor for VNI of CCTA at 80 keV, QIR2 (R2 = 0.12) to moderate for VNI of LE at 60 keV, QIR4; 70 keV, QIR3 and 4; and VNC of LE, QIR3 and 4 (all, R2 = 0.58). In the validation cohort (29 men, age 75 ± 14 years), synthetic hematocrit was calculated from VNC of the LE scan, QIR3. Median ECV was 26.9% (interquartile range (IQR), 25.5%, 28.8%) using the blood hematocrit and 26.8% (IQR, 25.4%, 29.7%) using synthetic hematocrit (VNC, QIR3; mean difference, -0.2%; limits of agreement, -2.4%, 2.0%; p = 0.33). CONCLUSION: Synthetic hematocrit calculated from VNC images enables an accurate computation of myocardial ECV with PCD-CT. CLINICAL RELEVANCE STATEMENT: Virtual non-contrast images from cardiac late enhancement scans with photon-counting detector CT allow the calculation of a synthetic hematocrit, which enables accurate computation of myocardial extracellular volume. KEY POINTS: Blood hematocrit is mandatory for conventional myocardial extracellular volume computation. Synthetic hematocrit can be calculated from virtual non-iodine and non-contrast photon-counting detector CT images. Synthetic hematocrit from virtual non-contrast images enables computation of the myocardial extracellular volume.

12.
Cancers (Basel) ; 16(10)2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38792005

RESUMO

This review highlights recent advances in renal cell carcinoma (RCC) imaging. It begins with dual-energy computed tomography (DECT), which has demonstrated a high diagnostic accuracy in the evaluation of renal masses. Several studies have suggested the potential benefits of iodine quantification, particularly for distinguishing low-attenuation, true enhancing solid masses from hyperdense cysts. By determining whether or not a renal mass is present, DECT could avoid the need for additional imaging studies, thereby reducing healthcare costs. DECT can also provide virtual unenhanced images, helping to reduce radiation exposure. The review then provides an update focusing on the advantages of multiparametric magnetic resonance (MR) imaging performance in the histological subtyping of RCC and in the differentiation of benign from malignant renal masses. A proposed standardized stepwise reading of images helps to identify clear cell RCC and papillary RCC with a high accuracy. Contrast-enhanced ultrasound may represent a promising diagnostic tool for the characterization of solid and cystic renal masses. Several combined pharmaceutical imaging strategies using both sestamibi and PSMA offer new opportunities in the diagnosis and staging of RCC, but their role in risk stratification needs to be evaluated. Although radiomics and tumor texture analysis are hampered by poor reproducibility and need standardization, they show promise in identifying new biomarkers for predicting tumor histology, clinical outcomes, overall survival, and the response to therapy. They have a wide range of potential applications but are still in the research phase. Artificial intelligence (AI) has shown encouraging results in tumor classification, grade, and prognosis. It is expected to play an important role in assessing the treatment response and advancing personalized medicine. The review then focuses on recently updated algorithms and guidelines. The Bosniak classification version 2019 incorporates MRI, precisely defines previously vague imaging terms, and allows a greater proportion of masses to be placed in lower-risk classes. Recent studies have reported an improved specificity of the higher-risk categories and better inter-reader agreement. The clear cell likelihood score, which adds standardization to the characterization of solid renal masses on MRI, has been validated in recent studies with high interobserver agreement. Finally, the review discusses the key imaging implications of the 2017 AUA guidelines for renal masses and localized renal cancer.

13.
J Med Imaging (Bellingham) ; 11(Suppl 1): S12804, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38799270

RESUMO

Purpose: We aim to reduce image noise in high-resolution (HR) virtual monoenergetic images (VMIs) from photon-counting detector (PCD) CT scans by developing a prior knowledge-aware iterative denoising neural network (PKAID-Net) that efficiently exploits the unique noise characteristics of VMIs at different energy (keV) levels. Approach: PKAID-Net offers two major features: first, it utilizes a lower-noise VMI (e.g., 70 keV) as a prior input; second, it iteratively constructs a refined training dataset to improve the neural network's denoising performance. In each iteration, the denoised image from the previous module serves as an updated target image, which is included in the dataset for the subsequent training iteration. Our study includes 10 patient coronary CT angiography exams acquired on a clinical dual-source PCD-CT (NAEOTOM Alpha, Siemens Healthineers). The HR VMIs were reconstructed at 50, 70, and 100 keV, using a sharp vascular kernel (Bv68) and thin (0.6 mm) slice thickness (0.3 mm increment). PKAID-Net's performance was evaluated in terms of image noise, spatial detail preservation, and quantitative accuracy. Results: PKAID-Net achieved a noise reduction of 96% compared to filtered back projection and 65% relative to iterative reconstruction, all while preserving spatial and spectral fidelity and maintaining a natural noise texture. The iterative refinement of PCD-CT data during the training process substantially enhanced the robustness of deep learning-based denoising compared to the original method, which resulted in some spatial detail loss. Conclusions: The PKAID-Net provides substantial noise reduction while maintaining spatial and spectral fidelity of the HR VMIs from PCD-CT.

14.
J Med Imaging (Bellingham) ; 11(Suppl 1): S12803, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38799271

RESUMO

Purpose: We aim to compare the low-contrast detectability of a clinical whole-body photon-counting-detector (PCD)-CT at different scan modes and image types with an energy-integrating-detector (EID)-CT. Approach: We used a channelized Hotelling observer (CHO) previously optimized for quality control purposes. An American College of Radiology CT accreditation phantom was scanned on both PCD-CT and EID-CT with 10 phantom positionings. For PCD-CT, images were generated using two scan modes, standard resolution (SR) and ultra-high-resolution (UHR); two image types, virtual monochromatic images at 70 keV and low-energy threshold (T3D); both filtered-back-projection (FBP) and iterative reconstruction (IR) reconstruction methods; and three reconstruction kernels. For each positioning, three repeated scans were acquired for each scan mode, image type, and CTDIvol of 6, 12, and 24 mGy. For EID-CT, images acquired from scans (10 positionings × 3 repeats × 3 doses) were reconstructed using the closest counterpart FBP and IR kernels. CHO was applied to calculate the index of detectability (d') on both scanners. Results: With the smooth Br44 kernel, the d' of UHR was mostly comparable with that of the SR mode (difference: -11.4% to 8.3%, p=0.020 to 0.956), and the T3D images had a higher d' (difference: 0.7% to 25.6%) than 70 keV images on PCD-CT. Compared with the EID-CT, UHR-T3D of PCD-CT had non-inferior d' (difference: -2.7% to 12.9%) with IR and non-superior d' (difference: 0.8% to 11.2%) with FBP using the Br44 kernel. PCD-CT produced higher d' than EID-CT by 61.8% to 247.1% with the sharper reconstruction kernels. Conclusions: The comparison between PCD-CT and EID-CT was significantly influenced by the reconstruction method and kernel. With a smooth kernel that is typically used in low-contrast detection tasks, the PCD-CT demonstrated low-contrast detectability that was comparable to EID-CT with IR and showed no superiority when using FBP. With the use of sharper kernels, the PCD-CT significantly outperformed EID-CT in low-contrast detectability.

15.
Eur Radiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634875

RESUMO

PURPOSE: To compare the diagnostic approach of acute pulmonary embolism (PE) with photon-counting-detector CT (PCD-CT) and energy-integrating-detector CT (EID-CT). MATERIALS AND METHODS: Two cohorts underwent CT angiographic examinations with EID-CT (Group 1; n = 158) and PCD-CT (Group 2; n = 172), (b) with two options in Group 1, dual energy (Group 1a) or single energy (Group 1b) and a single option in Group 2 (spectral imaging with single source). RESULTS: In Group 2, all patients benefited from spectral imaging, only accessible to 105 patients (66.5%) in Group 1, with a mean acquisition time significantly shorter (0.9 ± 0.1 s vs 4.0 ± 0 .3 s; p < 0.001) and mean values of CTDIvol and DLP reduced by 46.3% and 47.7%, respectively. Comparing the quality of 70 keV (Group 2) and averaged (Group 1a) images: (a) the mean attenuation within pulmonary arteries did not differ (p = 0.13); (b) the image noise was significantly higher (p < 0.001) in Group 2 with no difference in subjective image noise (p = 0.29); and (c) 89% of examinations were devoid of artifacts in Group 2 vs 28.6% in Group 1a. The percentage of diagnostic examinations was 95.2% (100/105; Group 1a), 100% (53/53; Group 1b), and 95.3% (164/172; Group 2). There were 4.8% (5/105; Group 1a) and 4.7% (8/172; Group 2) of non-diagnostic examinations, mainly due to the suboptimal quality of vascular opacification with the restoration of a diagnostic image quality on low-energy images. CONCLUSION: Compared to EID-CT, morphology and perfusion imaging were available in all patients scanned with PCD-CT, with the radiation dose reduced by 48%. CLINICAL RELEVANCE STATEMENT: PCD-CT enables scanning patients with the advantages of both spectral imaging, including high-quality morphologic imaging and lung perfusion for all patients, and fast scanning-a combination that is not simultaneously accessible with EID-CT while reducing the radiation dose by almost 50%.

16.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38667745

RESUMO

Photon-counting detector computed tomography (PCD-CT) represents a revolutionary new generation of computed tomography (CT) for the imaging of patients with cardiovascular diseases. Since its commercial market introduction in 2021, numerous studies have identified advantages of this new technology in the field of cardiovascular imaging, including improved image quality due to an enhanced contrast-to-noise ratio, superior spatial resolution, reduced artifacts, and a reduced radiation dose. The aim of this narrative review was to discuss the current scientific literature, and to find answers to the question of whether PCD-CT has yet led to a true step-change and significant progress in cardiovascular imaging.

17.
Acta Med Okayama ; 78(2): 135-142, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38688831

RESUMO

This study aimed to evaluate the potential reduction in contrast medium utilization using photon-counting detector computed tomography (PCD-CT). One PCD-CT scan (CT1) and three conventional (non-PCD-CT) CT scans (CT2-CT4) were performed using a multi-energy CT phantom that contained eight rods with different iodine concentrations (0.2, 0.5, 1, 2, 5, 10, 15, and 20 mg/ml). The CT values of the seven groups (CT1 for 40, 50, 60, and 70 keV; and CT2-4) were measured. Noise and contrast-to-noise ratio (CNR) were assessed for the eight rods at various iodine concentrations. CT2 and CT1 (40 keV) respectively required 20 mg/ml and 5 mg/ml of iodine, indicating that a comparable contrast effect could be obtained with approximately one-fourth of the contrast medium amount. The standard deviation values increased at lower energy levels irrespective of the iodine concentration. The CNR exhibited a decreasing trend with lower iodine concentrations, while it remained relatively stable across all iodine levels (40-70 keV). This study demonstrated that virtual monochromatic 40 keV images offer a similar contrast effect with a reduced contrast medium amount when compared to conventional CT systems at 120 kV.


Assuntos
Meios de Contraste , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X , Meios de Contraste/química , Tomografia Computadorizada por Raios X/métodos , Iodo , Humanos
18.
Radiol Cardiothorac Imaging ; 6(2): e240020, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38602468

RESUMO

Radiology: Cardiothoracic Imaging publishes novel research and technical developments in cardiac, thoracic, and vascular imaging. The journal published many innovative studies during 2023 and achieved an impact factor for the first time since its inaugural issue in 2019, with an impact factor of 7.0. The current review article, led by the Radiology: Cardiothoracic Imaging trainee editorial board, highlights the most impactful articles published in the journal between November 2022 and October 2023. The review encompasses various aspects of coronary CT, photon-counting detector CT, PET/MRI, cardiac MRI, congenital heart disease, vascular imaging, thoracic imaging, artificial intelligence, and health services research. Key highlights include the potential for photon-counting detector CT to reduce contrast media volumes, utility of combined PET/MRI in the evaluation of cardiac sarcoidosis, the prognostic value of left atrial late gadolinium enhancement at MRI in predicting incident atrial fibrillation, the utility of an artificial intelligence tool to optimize detection of incidental pulmonary embolism, and standardization of medical terminology for cardiac CT. Ongoing research and future directions include evaluation of novel PET tracers for assessment of myocardial fibrosis, deployment of AI tools in clinical cardiovascular imaging workflows, and growing awareness of the need to improve environmental sustainability in imaging. Keywords: Coronary CT, Photon-counting Detector CT, PET/MRI, Cardiac MRI, Congenital Heart Disease, Vascular Imaging, Thoracic Imaging, Artificial Intelligence, Health Services Research © RSNA, 2024.


Assuntos
Apêndice Atrial , Cardiopatias Congênitas , Radiologia , Humanos , Meios de Contraste , Inteligência Artificial , Gadolínio , Tomografia Computadorizada por Raios X
19.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535045

RESUMO

OBJECTIVES: The aim of this study was to analyze the extent of dental metal artifacts in virtual monoenergetic (VME) images, as they often compromise image quality by obscuring soft tissue affecting vascular attenuation reducing sensitivity in the detection of dissections. METHODS: Neck photon-counting CT datasets of 50 patients undergoing contrast-enhanced trauma CT were analyzed. Hyperattenuation and hypoattenuation artifacts, muscle with and without artifacts and vessels with and without artifacts were measured at energy levels from 40 keV to 190 keV. The corrected artifact burden, corrected image noise and artifact index were calculated. We also assessed subjective image quality on a Likert-scale. RESULTS: Our study showed a lower artifact burden and less noise in artifact-affected areas above the energy levels of 70 keV for hyperattenuation artifacts (conventional polychromatic CT images 1123 ± 625 HU vs. 70 keV VME 1089 ± 733 HU, p = 0.125) and above of 80 keV for hypoattenuation artifacts (conventional CT images -1166 ± 779 HU vs. 80 keV VME -1170 ± 851 HU, p = 0.927). Vascular structures were less hampered by metal artifacts than muscles (e.g., corrected artifact burden at 40 keV muscle 158 ± 125 HU vs. vessels -63 ± 158 HU p < 0.001), which was also reflected in the subjective image assessment, which showed better ratings at higher keV values and overall better ratings for vascular structures than for the overall artifact burden. CONCLUSIONS: Our research suggests 70 keV might be the best compromise for reducing metal artifacts affecting vascular structures and preventing vascular contrast if solely using VME reconstructions. VME imaging shows only significant effects on the general artifact burden. Vascular structures generally experience fewer metal artifacts than soft tissue due to their greater distance from the teeth, which are a common source of such artifacts.

20.
Diagnostics (Basel) ; 14(6)2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38535047

RESUMO

BACKGROUND: Photon-counting detector (PCD) computed tomography (CT) allows for the reconstruction of virtual monoenergetic images (VMI) at different thresholds. OBJECTIVE: The aim of our study was to evaluate the optimal arterial contrast in portal venous (pv) scans regarding objective parameters and subjective image quality for different virtual keV levels. METHODS: We identified 40 patients that underwent a CT scan with an arterial and pv phase on a PCD-CT (NAEOTOM alpha, Siemens Healthineers, Forchheim, Germany). The attenuation of abdominal arteries on pv phases was measured for different virtual keV levels in a monoenergetic+ application profile and for polychromatic (pc) arterial images. Two independent readers assessed subjective image quality, including vascular contrast in pv scans at different energy levels. Additionally, signal- and contrast-to-noise ratios (SNR and CNR) were measured. RESULTS: Our results showed increasing arterial attenuation levels with decreasing energy levels in virtual monoenergetic imaging on pv scans with the highest attenuation at 40 keV, significantly higher than in the pc arterial phase (439 ± 97 HU vs. 360 ± 97, p < 0.001). Noise, SNR, and CNR were worse at this energy level (p < 0.001). Pv VMI showed less noise at energy levels above 70 keV (all p < 0.001). Subjective image quality was rated best at 70 keV, vascular contrast was best at 40 keV. CONCLUSIONS: Our research suggests that virtual monoenergetic images at 40 keV in Mono+ mode derived from a PCD-CT can be a feasible alternative to a true arterial phase for assessment of vessels with worse CNR and SNR.