Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 15(9)2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39337829

RESUMO

DNA is fundamental for storing and transmitting genetic information. Analyzing DNA or RNA base sequences enables the identification of genetic disorders, monitoring gene expression, and detecting pathogens. Traditional detection techniques like polymerase chain reaction (PCR) and next-generation sequencing (NGS) have limitations, including complexity, high cost, and the need for advanced computational skills. Therefore, there is a significant demand for enzyme-free and amplification-free strategies for rapid, low-cost, and sensitive DNA detection. DNA biosensors, especially those utilizing plasmonic nanomaterials, offer a promising solution. This study introduces a novel DNA-functionalized waveguide-enhanced nanoplasmonic optofluidic biosensor using a nanogold-linked sorbent assay for enzyme-free and amplification-free DNA detection. Integrating plasmonic gold nanoparticles (AuNPs) with a glass planar waveguide (WG) and a microfluidic channel, fabricated through cost-effective, vacuum-free methods, the biosensor achieves specific detection of complementary target DNA sequences. Utilizing a sandwich architecture, AuNPs labeled with detection DNA probes enhance sensitivity by altering evanescent wave distribution and inducing plasmon resonance modes. The biosensor demonstrated exceptional performance in DNA detection, achieving a limit of detection (LOD) of 33.1 fg/mL (4.36 fM) with a rapid response time of approximately 8 min. This ultrasensitive, rapid, and cost-effective biosensor exhibits minimal background nonspecific adsorption, making it highly suitable for clinical applications and early disease diagnosis. The innovative design and fabrication processes offer significant advantages for mass production, presenting a viable tool for precise disease diagnostics and improved clinical outcomes.

2.
Open Res Eur ; 4: 44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39148583

RESUMO

Nitrogen-vacancy (NV) centers in diamond have emerged as promising quantum sensors due to their highly coherent and optically addressable spin states with potential applications in high-sensitivity magnetometry. Homogeneously addressing large ensembles of NV centers offers clear benefit in terms of sensing precision as well as in fundamental studies of collective effects. Such experiments require a spatially uniform, intense, and broadband microwave field that can be difficult to generate. Previous approaches, such as copper wires, loop coils, and planar structures, have shown limitations in field homogeneity, bandwidth, and integration in compact devices. In this paper, we present a coplanar waveguide (CPW) gold coil patterned on a 3 × 3 mm 2 diamond substrate, offering full integration, enhanced stability, and broad bandwidth suitable for various NV sensing applications. Coil fabricated on diamond offers several advantages for magnetometry with NV centers ensemble, including enhanced heat dissipation, seamless integration, scalability, and miniaturization potential. We optimize critical geometrical parameters to achieve a homogeneous magnetic field with a coefficient of variation of less than 6% over an area of 0.5 mm 2 and present experimental results confirming the performance of the proposed CPW coil.


In recent years, there has been significant interest in using nitrogen-vacancy (NV) centers in diamond as quantum sensors for high-sensitivity magnetometry. These NV centers, particularly the negatively charged ones, offer promising applications due to their coherent spin states that can be manipulated using microwave fields and optically detected magnetic resonance techniques. However, to improve measurement precision and signal-to-noise ratio, it's advantageous to address large ensembles of NV centers, which requires a spatially uniform, intense, and broadband microwave field. Various methods, such as copper wires, loop coils, and planar structures, have been explored to achieve this, but with limited capability. To address their limitations, a coplanar waveguide (CPW) gold coil patterned on a CVD diamond substrate is proposed. This design offers a highly homogeneous magnetic field, full integration with the diamond substrate, scalability, miniaturization, and efficient heat dissipation, making it a promising solution for NV magnetometry applications. Experimental results confirm its performance, making it a remarkable advancement in this area.

3.
Nanomaterials (Basel) ; 14(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38607130

RESUMO

The achievement of the low Gilbert damping parameter in spin dynamic modulation is attractive for spintronic devices with low energy consumption and high speed. Metallic ferromagnetic alloy Co-Fe-B is a possible candidate due to its high compatibility with spintronic technologies. Here, we report thickness-dependent damping and soft magnetism in Co-Fe-B films sandwiched between two non-magnetic layers with Co-Fe-B films up to 50 nm thick. A non-monotonic variation of Co-Fe-B film damping with thickness is observed, which is in contrast to previously reported monotonic trends. The minimum damping and the corresponding Co-Fe-B thickness vary significantly among the different non-magnetic layer series, indicating that the structure selection significantly alters the relative contributions of various damping mechanisms. Thus, we developed a quantitative method to distinguish intrinsic from extrinsic damping via ferromagnetic resonance measurements of thickness-dependent damping rather than the traditional numerical calculation method. By separating extrinsic and intrinsic damping, each mechanism affecting the total damping of Co-Fe-B films in sandwich structures is analyzed in detail. Our findings have revealed that the thickness-dependent damping measurement is an effective tool for quantitatively investigating different damping mechanisms. This investigation provides an understanding of underlying mechanisms and opens up avenues for achieving low damping in Co-Fe-B alloy film, which is beneficial for the applications in spintronic devices design and optimization.

4.
Nano Lett ; 24(8): 2596-2602, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38251930

RESUMO

Sepsis, a life-threatening inflammatory response, demands economical, accurate, and rapid detection of biomarkers during the critical "golden hour" to reduce the patient mortality rate. Here, we demonstrate a cost-effective waveguide-enhanced nanogold-linked immunosorbent assay (WENLISA) based on nanoplasmonic waveguide biosensors for the rapid and sensitive detection of procalcitonin (PCT), a sepsis-related inflammatory biomarker. To enhance the limit of detection (LOD), we employed sandwich assays using immobilized capture antibodies and detection antibodies conjugated to gold nanoparticles to bind the target analyte, leading to a significant evanescent wave redistribution and strong nanoplasmonic absorption near the waveguide surface. Experimentally, we detected PCT for a wide linear response range of 0.1 pg/mL to 1 ng/mL with a record-low LOD of 48.7 fg/mL (3.74 fM) in 8 min. Furthermore, WENLISA has successfully identified PCT levels in the blood plasma of patients with sepsis and healthy individuals, offering a promising technology for early sepsis diagnosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Sepse , Humanos , Pró-Calcitonina , Imunoadsorventes , Ouro , Sepse/diagnóstico , Biomarcadores , Anticorpos Imobilizados
5.
J Biophotonics ; 16(9): e202300148, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37280718

RESUMO

A dynamically tunable metal clad planar waveguide having 0.62PMN-0.38PT material is simulated and optimized for detection of cancer cells. Angular interrogation of the TE0 mode of waveguide shows that critical angle increases greater than the resonance angle with increasing of cover refractive index, which limits the detection range of waveguide. To overcome this limitation, proposed waveguide applies a potential on the PMN-PT adlayer. Although a sensitivity of 105.42 degree/RIU was achieved at 70 Volts in testing the proposed waveguide, it was found that the optimal performance parameters were obtained at 60 Volts. At this voltage, the waveguide demonstrated detection range 1.3330-1.5030, a detection accuracy 2393.33, and a figure of merit 2243.59 RIU-1 , which enabled the detection of the entire range of the targeted cancer cells. Therefore, it is recommended to apply a potential of 60 Volts to achieve the best performance from the proposed waveguide.


Assuntos
Metais , Neoplasias , Vibração , Neoplasias/diagnóstico por imagem
6.
Heliyon ; 8(11): e11706, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36439740

RESUMO

In mode division multiplexing (MDM) optical system, the mode filter has become an inseparable part to reduce modal crosstalk and transmit the desired modes unabatedly. As filtering out lower-order mode is difficult, here we propose a reconfigurable structure of a higher-order mode pass filter consisting of two tunable mode converters and a directional coupler (DC) in a three-mode planar waveguide platform. By switching the working states of the mode converters, the structure can also be used as a fundamental mode (TE0) pass filter and hence dynamic output signals can be achieved. For the second-order mode (TE2) transmission, the simulated excess loss is ∼0.61 dB at 1.550 µm and the extinction ratio remains ≥24 dB (power ratio of TE0 & TE2 Launch) and ≥25 dB (power ratio of TE1 & TE2 Launch) at the entire C-band (1.530-1.565 µm). The device has negligible polarization dependence and hence the TM polarization exhibits similar results.

7.
Materials (Basel) ; 15(21)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36363233

RESUMO

Composite silica-titania waveguide films of refractive index ca. 1.8 are fabricated on glass substrates using a sol-gel method and dip-coating technique. Tetraethyl orthosilicate and tetraethyl orthotitanate with molar ratio 1:1 are precursors. Fabricated waveguides are annealed at 500 °C for 60 min. Their optical properties are studied using ellipsometry and UV-Vis spectrophotometry. Optical losses are determined using the streak method. The material structure and chemical composition, of the silica-titania films are analyzed using transmission electron microscopy (TEM) and electron dispersive spectroscopy (EDS), respectively. The surface morphology was investigated using atomic force microscopy (AFM) and scanning electron microscopy (SEM) methods. The results presented in this work show that the waveguide films are amorphous, and their parameters are stable for over a 13 years. The optical losses depend on their thickness and light polarization. Their lowest values are less than 0.06 dB cm-1. The paper presents the results of theoretical analysis of scattering losses on nanocrystals and pores in the bulk and interfaces of the waveguide film. These results combined with experimental data clearly indicate that light scattering at the interface to a glass substrate is the main source of optical losses. Presented waveguide films are suitable for application in evanescent wave sensors.

8.
Nanomaterials (Basel) ; 12(20)2022 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-36296743

RESUMO

A double-layer metal superlens was rigorously analyzed and systematically designed to improve subwavelength imaging ability. It was revealed that transmission properties of the imaging system could be accurately interpreted by the five-layer waveguide mode theory-each amplification peak among the spatial frequency range of evanescent waves was associated with a corresponding surface plasmon polariton (SPP) mode of an insulator-metal-insulator-metal-insulator (IMIMI) structure. On the basis of such physical insight, evanescent waves of higher spatial frequency were effectively amplified via increasing propagation constants of symmetrically coupled short-range SPP (s-SRSPP) and antisymmetrically coupled short-range SPP (a-SRSPP), and evanescent waves of lower spatial frequency were appropriately diminished by approaching to cut off symmetrically coupled long-range SPP (s-LRSPP). A flat and broad optical transfer function of the imaging system was then achieved, and improved subwavelength imaging performance was validated by imaging an ideal thin object of two slits with a 20-nm width distanced by a 20-nm spacer, under 193-nm illumination. The resolution limit of the designed imaging system with double-layer superlens was further demonstrated to be at least ~λ/16 for an isolated two-slit object model. This work provided sound theoretical analysis and a systematic design approach of double-layer metal superlens for near-field subwavelength imaging, such as fluorescent micro/nanoscopy or plasmonic nanolithography.

9.
Biosensors (Basel) ; 12(6)2022 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-35735551

RESUMO

The development of resonance phenomena-based optical biosensors has gained relevance in recent years due to the excellent optical fiber properties and progress in the research on materials and techniques that allow resonance generation. However, for lossy mode resonance (LMR)-based sensors, the optical fiber presents disadvantages, such as the need for splicing the sensor head and the complex polarization control. To avoid these issues, planar waveguides such as coverslips are easier to handle, cost-effective, and more robust structures. In this work, a microfluidic LMR-based planar waveguide platform was proposed, and its use for biosensing applications was evaluated by detecting anti-immunoglobulin G (anti-IgG). In order to generate the wavelength resonance, the sensor surface was coated with a titanium dioxide (TiO2) thin-film. IgG antibodies were immobilized by covalent binding, and the detection assay was carried out by injecting anti-IgG in PBS buffer solutions from 5 to 20 µg/mL. The LMR wavelength shifted to higher values when increasing the analyte concentration, which means that the proposed system was able to detect the IgG/anti-IgG binding. The calibration curve was built from the experimental data obtained in three repetitions of the assay. In this way, a prototype of an LMR-based biosensing microfluidic platform developed on planar substrates was obtained for the first time.


Assuntos
Técnicas Biossensoriais , Microfluídica , Bioensaio , Imunoglobulina G , Fibras Ópticas
10.
Sensors (Basel) ; 22(4)2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35214410

RESUMO

A planar waveguide consisting of a coverslip for a microscope glass slide was deposited in one of its two faces with two materials: silver and indium tin oxide (ITO). The incidence of light by the edge of the coverslip permitted the generation of both surface plasmon and lossy mode resonances (SPRs and LMRs) in the same transmission spectrum with a single optical source and detector. This proves the ability of this optical platform to be used as a benchmark for comparing different optical phenomena generated by both metal and dielectric materials, which can be used to progress in the assessment of different sensing technologies. Here the SPR and the LMR were compared in terms of sensitivity to refractive index and figure of merit (FoM), at the same time it was demonstrated that both resonances can operate independently when silver and ITO coated regions are surrounded by different refractive index liquids. The results were supported with numerical results that confirm the experimental ones.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA