Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 171
Filtrar
1.
Food Res Int ; 191: 114690, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39059946

RESUMO

Anhydrous milk fat (AMF) and its fractions are used as ingredients in a wide range of food applications. Obtaining the appropriate solid fat content (SFC) is essential to achieve the desired product texture. At present, in-line monitoring techniques to control milk fat crystallization and melting are largely unavailable. The thermal behaviour of milk fat (AMF and four of its fractions) was monitored in a temperature-controlled vessel using an in-line Raman analyser and compared with thermograms generated using differential scanning calorimetry (DSC). The major stages of milk fat crystallization and melting were identified using the in-line Raman analyser. Thermal data from DSC showed excellent linear correlations with Raman spectral data (R2 value of 0.97 for the onset of milk fat crystallisation). Partial least squares regression (PLSR) models were developed using Raman spectra to predict SFC with coefficient of determination (R2Cs) from 0.929 to 0.992 and root mean standard error of calibration (RMSECs) ranging from 3.20 to 10.36%. Results demonstrated Raman spectroscopy has significant potential as a way of monitoring milk fat crystallization and melting processes.


Assuntos
Varredura Diferencial de Calorimetria , Cristalização , Leite , Análise Espectral Raman , Análise Espectral Raman/métodos , Leite/química , Animais , Análise dos Mínimos Quadrados , Temperatura de Transição
2.
Biotechnol Prog ; : e3493, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953182

RESUMO

Total sialic acid content (TSA) in biotherapeutic proteins is often a critical quality attribute as it impacts the drug efficacy. Traditional wet chemical assays to quantify TSA in biotherapeutic proteins during cell culture typically takes several hours or longer due to the complexity of the assay which involves isolation of sialic acid from the protein of interest, followed by sample preparation and chromatographic based separation for analysis. Here, we developed a machine learning model-based technology to rapidly predict TSA during cell culture by using typically measured process parameters. The technology features a user interface, where the users only have to upload cell culture process parameters as input variables and TSA values are instantly displayed on a dashboard platform based on the model predictions. In this study, multiple machine learning algorithms were assessed on our dataset, with the Random Forest model being identified as the most promising model. Feature importance analysis from the Random Forest model revealed that attributes like viable cell density (VCD), glutamate, ammonium, phosphate, and basal medium type are critical for predictions. Notably, while the model demonstrated strong predictability by Day 14 of observation, challenges remain in forecasting TSA values at the edges of the calibration range. This research not only emphasizes the transformative power of machine learning and soft sensors in bioprocessing but also introduces a rapid and efficient tool for sialic acid prediction, signaling significant advancements in bioprocessing. Future endeavors may focus on data augmentation to further enhance model precision and exploration of process control capabilities.

3.
Int J Pharm ; 661: 124405, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38950660

RESUMO

High shear wet granulation (HSWG) is widely used in tablet manufacturing mainly because of its advantages in improving flowability, powder handling, process run time, size distribution, and preventing segregation. In line process analytical technology measurements are essential in capturing detailed particle dynamics and presenting real-time data to uncover the complexity of the HSWG process and ultimately for process control. This study presents an opportunity to predict the properties of the granules and tablets through torque measurement of the granulation bowl and the force exerted on a novel force probe within the powder bed. Inline force measurements are found to be more sensitive than torque measurements to the granulation process. The characteristic force profiles present the overall fingerprint of the high shear wet granulation, in which the evolution of the granule formation can improve our understanding of the granulation process. This provides rich information relating to the properties of the granules, identification of the even distribution of the binder liquid, and potential granulation end point. Data were obtained from an experimental high shear mixer across a range of key process parameters using a face-centred surface response design of experiment (DoE). A closed-form analytical model was developed from the DOE matrix using the discovery of evolutionary equations. The model is able to provide a strong predictive indication of the expected tablet tensile strength based only on the data in-line. The use of a closed form mathematical equation carries notable advantages over other AI methodologies such as artificial neural networks, notably improved interpretability/interrogability, and minimal inference costs, thus allowing the model to be used for real-time decision making and process control. The capability of accurately predicting, in real time, the required compaction force required to achieve the desired tablet tensile strength from upstream data carries the potential to ensure compression machine settings rapidly reach and are maintained at optimal values, thus maximising efficiency and minimising waste.


Assuntos
Excipientes , Pós , Comprimidos , Resistência à Tração , Comprimidos/química , Pós/química , Excipientes/química , Composição de Medicamentos/métodos , Tecnologia Farmacêutica/métodos , Tamanho da Partícula , Química Farmacêutica/métodos
4.
Int J Pharm ; 661: 124412, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38960339

RESUMO

Process Analytical Technology (PAT) has revolutionized pharmaceutical manufacturing by providing real-time monitoring and control capabilities throughout the production process. This review paper comprehensively examines the application of PAT methodologies specifically in the production of solid active pharmaceutical ingredients (APIs). Beginning with an overview of PAT principles and objectives, the paper explores the integration of advanced analytical techniques such as spectroscopy, imaging modalities and others into solid API substance production processes. Novel developments in in-line monitoring at academic level are also discussed. Emphasis is placed on the role of PAT in ensuring product quality, consistency, and compliance with regulatory requirements. Examples from existing literature illustrate the practical implementation of PAT in solid API substance production, including work-up, crystallization, filtration, and drying processes. The review addresses the quality and reliability of the measurement technologies, aspects of process implementation and handling, the integration of data treatment algorithms and current challenges. Overall, this review provides valuable insights into the transformative impact of PAT on enhancing pharmaceutical manufacturing processes for solid API substances.


Assuntos
Tecnologia Farmacêutica , Tecnologia Farmacêutica/métodos , Preparações Farmacêuticas/química , Preparações Farmacêuticas/análise , Química Farmacêutica/métodos
5.
J Pharm Sci ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38825234

RESUMO

The purpose of this study was to investigate the mechanical stresses and strains acting on pharmaceutical glass tubing vials during freezing and thawing of model pharmaceutical formulations. Strain measurements were conducted inside of a laboratory-scale freeze-dryer using a custom wireless sensor. In both sucrose and trehalose formulations at concentrations between 5 % and 20 % w/v, the strain measurements initially increased before peaking in magnitude at temperatures close to the respective glass transition temperatures of the maximally freeze concentrated solutes, Tg'. We attribute this behavior to a shift in the mechanical properties of the frozen system from a purely elastic glass below Tg' to a viscoelastic rubber-like material above Tg'. That is, when the interstitial region becomes mechanically compliant at temperature above Tg'. The outputs were less predictable below 5 % w/v and tended to exhibit two separate peaks in strain output, one near the equilibrium melting temperature of pure ice and the other near Tg'. The peaks merged at concentrations between 4 and 5 % w/v where the largest strain magnitude was observed. The strain on primary packaging has traditionally been applied to evaluate the risk of damage or breakage due to, for example, crystallization of excipients. However, data collected during this study suggest there may be utility in formulation design or as a process analytical technology to minimize potentially destabilizing stresses and strains in the frozen formulation.

6.
Front Bioeng Biotechnol ; 12: 1349473, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863496

RESUMO

Pharmaceutical manufacturing is reliant upon bioprocessing approaches to generate the range of therapeutic products that are available today. The high cost of production, susceptibility to process failure, and requirement to achieve consistent, high-quality product means that process monitoring is paramount during manufacturing. Process analytic technologies (PAT) are key to ensuring high quality product is produced at all stages of development. Spectroscopy-based technologies are well suited as PAT approaches as they are non-destructive and require minimum sample preparation. This study explored the use of a novel attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy platform, which utilises disposable internal reflection elements (IREs), as a method of upstream bioprocess monitoring. The platform was used to characterise organism health and to quantify cellular metabolites in growth media using quantification models to predict glucose and lactic acid levels both singularly and combined. Separation of the healthy and nutrient deficient cells within PC space was clearly apparent, indicating this technique could be used to characterise these classes. For the metabolite quantification, the binary models yielded R 2 values of 0.969 for glucose, 0.976 for lactic acid. When quantifying the metabolites in tandem using a multi-output partial least squares model, the corresponding R 2 value was 0.980. This initial study highlights the suitability of the platform for bioprocess monitoring and paves the way for future in-line developments.

7.
Front Bioeng Biotechnol ; 12: 1397465, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38812919

RESUMO

Protein crystallization as opposed to well-established chromatography processes has the benefits to reduce production costs while reaching a comparable high purity. However, monitoring crystallization processes remains a challenge as the produced crystals may interfere with analytical measurements. Especially for capturing proteins from complex feedstock containing various impurities, establishing reliable process analytical technology (PAT) to monitor protein crystallization processes can be complicated. In heterogeneous mixtures, important product characteristics can be found by multivariate analysis and chemometrics, thus contributing to the development of a thorough process understanding. In this project, an analytical set-up is established combining offline analytics, on-line ultraviolet visible light (UV/Vis) spectroscopy, and in-line Raman spectroscopy to monitor a stirred-batch crystallization process with multiple phases and species being present. As an example process, the enzyme Lactobacillus kefir alcohol dehydrogenase (LkADH) was crystallized from clarified Escherichia coli (E. coli) lysate on a 300 mL scale in five distinct experiments, with the experimental conditions changing in terms of the initial lysate solution preparation method and precipitant concentration. Since UV/Vis spectroscopy is sensitive to particles, a cross-flow filtration (cross-flow filtration)-based bypass enabled the on-line analysis of the liquid phase providing information on the lysate composition regarding the nucleic acid to protein ratio. A principal component analysis (PCA) of in situ Raman spectra supported the identification of spectra and wavenumber ranges associated with productspecific information and revealed that the experiments followed a comparable, spectral trend when crystals were present. Based on preprocessed Raman spectra, a partial least squares (PLS) regression model was optimized to monitor the target molecule concentration in real-time. The off-line sample analysis provided information on the crystal number and crystal geometry by automated image analysis as well as the concentration of LkADH and host cell proteins (HCPs) In spite of a complex lysate suspension containing scattering crystals and various impurities, it was possible to monitor the target molecule concentration in a heterogeneous, multi-phase process using spectroscopic methods. With the presented analytical set-up of off-line, particle-sensitive on-line, and in-line analyzers, a crystallization capture process can be characterized better in terms of the geometry, yield, and purity of the crystals.

8.
Int J Pharm ; 657: 124124, 2024 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-38636678

RESUMO

Continuous manufacturing of pharmaceuticals offers several benefits, such as increased production efficiency, enhanced product quality control, and lower environmental footprint. To fully exploit these benefits, standard operation mode (production processes with no or minimal disturbance mitigation measures) should be supported by adopting novel quality-by-control (QbC) methodologies. The paper at hand is the first part of a study focused on developing QbC algorithms for optimizing twin-screw wet granulation in the industrial manufacturing line ConsiGmaTM-25, specifically addressing granule composition. This work relies on previously established process-analytical-technology (PAT) equipment for real-time monitoring of the granule composition, i.e., the active pharmaceutical ingredient (API) and liquid content in wet granules. The developed control platform integrates model-based process control algorithms that aim to keep the API- and liquid content at target values through real-time adjustments of the process parameters. Furthermore, the platform integrates a digital operator assistant, which aims to detect and classify granulation disturbances and provides messages and instructions for the plant operator. The present manuscript systematically outlines all design steps from the development phase in the simulation environment to the final real system application and validation. The control platform's performance is demonstrated through selected test scenarios on the ConsiGmaTM-25 manufacturing line. The obtained results indicate improved disturbance robustness and an increase in intermediate/final product quality (compared to conventional operating modes): The process control algorithms successfully maintained the API- and liquid content at target values despite process disturbances. Furthermore, realistic disturbances (feeder, pump, and material) were accurately detected and classified by the digital assistant algorithm. The information was provided through a user interface, offering real-time support for plant personnel.


Assuntos
Algoritmos , Composição de Medicamentos , Controle de Qualidade , Tecnologia Farmacêutica , Tecnologia Farmacêutica/métodos , Composição de Medicamentos/métodos , Excipientes/química , Tamanho da Partícula , Química Farmacêutica/métodos
9.
Biotechnol Bioeng ; 121(7): 2225-2233, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38678541

RESUMO

Process in-line monitoring and control are crucial to optimize the productivity of bioprocesses. A frequently applied Process Analytical Technology (PAT) tool for bioprocess in-line monitoring is Raman spectroscopy. However, evaluating bioprocess Raman spectra is complex and calibrating state-of-the-art statistical evaluation models is effortful. To overcome this challenge, we developed an Indirect Hard Modeling (IHM) prediction model in a previous study. The combination of Raman spectroscopy and the IHM prediction model enables non-invasive in-line monitoring of glucose and ethanol mass fractions during yeast fermentations with significantly less calibration effort than comparable approaches based on statistical models. In this study, we advance this IHM-based approach and successfully demonstrate that the combination of Raman spectroscopy and IHM is capable of not only bioprocess monitoring but also bioprocess control. For this purpose, we used this combination's in-line information as input of a simple on-off glucose controller to control the glucose mass fraction in Saccharomyces cerevisiae fermentations. When we performed two of these fermentations with different predefined glucose set points, we achieved similar process control quality as approaches using statistical models, despite considerably smaller calibration effort. Therefore, this study reaffirms that the combination of Raman spectroscopy and IHM is a powerful PAT tool for bioprocesses.


Assuntos
Etanol , Glucose , Saccharomyces cerevisiae , Análise Espectral Raman , Análise Espectral Raman/métodos , Saccharomyces cerevisiae/metabolismo , Glucose/metabolismo , Glucose/análise , Etanol/metabolismo , Etanol/análise , Fermentação , Modelos Biológicos , Reatores Biológicos
10.
Anal Bioanal Chem ; 416(12): 3019-3032, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573344

RESUMO

Inclusion bodies (IBs) are protein aggregates formed as a result of overexpression of recombinant protein in E. coli. The formation of IBs is a valuable strategy of recombinant protein production despite the need for additional processing steps, i.e., isolation, solubilization and refolding. Industrial process development of protein refolding is a labor-intensive task based largely on empirical approaches rather than knowledge-driven strategies. A prerequisite for knowledge-driven process development is a reliable monitoring strategy. This work explores the potential of intrinsic tryptophan and tyrosine fluorescence for real-time and in situ monitoring of protein refolding. In contrast to commonly established process analytical technology (PAT), this technique showed high sensitivity with reproducible measurements for protein concentrations down to 0.01 g L - 1 . The change of protein conformation during refolding is reflected as a shift in the position of the maxima of the tryptophan and tyrosine fluorescence spectra as well as change in the signal intensity. The shift in the peak position, expressed as average emission wavelength of a spectrum, was correlated to the amount of folding intermediates whereas the intensity integral correlates to the extent of aggregation. These correlations were implemented as an observation function into a mechanistic model. The versatility and transferability of the technique were demonstrated on the refolding of three different proteins with varying structural complexity. The technique was also successfully applied to detect the effect of additives and process mode on the refolding process efficiency. Thus, the methodology presented poses a generic and reliable PAT tool enabling real-time process monitoring of protein refolding.


Assuntos
Corpos de Inclusão , Redobramento de Proteína , Espectrometria de Fluorescência , Corpos de Inclusão/química , Corpos de Inclusão/metabolismo , Espectrometria de Fluorescência/métodos , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Triptofano/química , Escherichia coli/metabolismo , Escherichia coli/química , Tirosina/química , Fluorescência , Dobramento de Proteína
11.
Chemistry ; 30(30): e202303692, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38462439

RESUMO

A novel class of diazonium salts is introduced for the photochemical aryl-aryl coupling to produce (substituted) biphenyls. As common diazonium tetrafluoroborate salts fail, soluble and safe aryl diazonium trifluoroacetates are applied. In this mild synthesis route no catalysts are required to generate an aryl-radical by irradiation with UV-A light (365 nm). This reactive species undergoes direct C-H arylation at an arene, forming the product in reasonable reaction times. With the implementation of a continuous flow setup in a capillary photoreactor 13 different biphenyl derivatives are successfully synthesized. By integrating an inline 19F-NMR benchtop spectrometer, samples are reliably quantified as the fluorine-substituents act as a probe. Here, real-time NMR spectroscopy is a perfect tool to monitor the continuously operated system, which produces fine chemicals of industrial relevance even in a multigram scale.

12.
Biotechnol Bioeng ; 121(5): 1688-1701, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38393313

RESUMO

Perfusion cell culture has been gaining increasing popularity for biologics manufacturing due to benefits such as smaller footprint, increased productivity, consistent product quality and manufacturing flexibility, cost savings, and so forth. Process Analytics Technologies tools are highly desirable for effective monitoring and control of long-running perfusion processes. Raman has been widely investigated for monitoring and control of traditional fed batch cell culture process. However, implementation of Raman for perfusion cell culture has been very limited mainly due to challenges with high-cell density and long running times during perfusion which cause extremely high fluorescence interference to Raman spectra and consequently it is exceedingly difficult to develop robust chemometrics models. In this work, a platform based on Raman measurement of permeate has been proposed for effective analysis of perfusion process. It has been demonstrated that this platform can effectively circumvent the fluorescence interference issue while providing rich and timely information about perfusion dynamics to enable efficient process monitoring and robust bioreactor feed control. With the highly consistent spectral data from cell-free sample matrix, development of chemometrics models can be greatly facilitated. Based on this platform, Raman models have been developed for good measurement of several analytes including glucose, lactate, glutamine, glutamate, and permeate titer. Performance of Raman models developed this way has been systematically evaluated and the models have shown good robustness against changes in perfusion scale and variations in permeate flowrate; thus models developed from small lab scale can be directly transferred for implementation in much larger scale of perfusion. With demonstrated robustness, this platform provides a reliable approach for automated glucose feed control in perfusion bioreactors. Glucose model developed from small lab scale has been successfully implemented for automated continuous glucose feed control of perfusion cell culture at much larger scale.


Assuntos
Técnicas de Cultura Celular por Lotes , Reatores Biológicos , Cricetinae , Animais , Cricetulus , Células CHO , Perfusão , Glucose/análise , Análise Espectral Raman
13.
Biotechnol Bioeng ; 121(4): 1257-1270, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38328831

RESUMO

Enabling real-time monitoring and control of the biomanufacturing processes through product quality insights continues to be an area of focus in the biopharmaceutical industry. The goal is to manufacture products with the desired quality attributes. To realize this rigorous attribute-focused Quality by Design approach, it is critical to support the development of processes that consistently deliver high-quality products and facilitate product commercialization. Time delays associated with offline analytical testing can limit the speed of process development. Thus, developing and deploying analytical technology is necessary to accelerate process development. In this study, we have developed the micro sequential injection process analyzer and the automatic assay preparation platform system. These innovations address the unmet need for an automatic, online, real-time sample acquisition and preparation platform system for in-process monitoring, control, and release of biopharmaceuticals. These systems can also be deployed in laboratory areas as an offline analytical system and on the manufacturing floor to enable rapid testing and release of products manufactured in a good manufacturing practice environment.


Assuntos
Tecnologia Farmacêutica , Controle de Qualidade
14.
Biotechnol Prog ; 40(2): e3424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38178645

RESUMO

The previous research showcased a partial least squares (PLS) regression model accurately predicting cell death percentages using in-line capacitance spectra. The current study advances the model accuracy through adaptive modeling employing a data fusion approach. This strategy enhances prediction performance by incorporating variables from the Cole-Cole model, conductivity and its derivatives over time, and Mahalanobis distance into the predictor matrix (X-matrix). Firstly, the Cole-Cole model, a mechanistic model with parameters linked to early cell death onset, was integrated to enhance prediction performance. Secondly, the inclusion of conductivity and its derivatives over time in the X-matrix mitigated prediction fluctuations resulting from abrupt conductivity changes during process operations. Thirdly, Mahalanobis distance, depicting spectral changes relative to a reference spectrum from a previous time point, improved model adaptability to independent test sets, thereby enhancing performance. The final data fusion model substantially decreased root-mean squared error of prediction (RMSEP) by around 50%, which is a significant boost in prediction accuracy compared to the prior PLS model. Robustness against reference spectrum selection was confirmed by consistent performance across various time points. In conclusion, this study illustrates that the data fusion strategy substantially enhances the model accuracy compared to the previous model relying solely on capacitance spectra.


Assuntos
Apoptose , Análise Espectral , Análise dos Mínimos Quadrados
15.
J Pharm Biomed Anal ; 241: 115965, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38237541

RESUMO

Real-time in-line broad protein content monitoring in biomanufacturing downstream unit operations enables the ability to optimize and afford consistent protein recovery. Protein determination from 2 to 400 mg/mL is demonstrated herein via real-time dual-wavelength LED photometric sensor configured at 280 and 310 nm. The figures of merit of this approach include measurement accuracy within the common acceptance criteria of 100 % ± 5 with negligible bias across the linear dynamic ranges. This work expands the utility of an LED based photometric sensor for biopharmaceutical process analytical technology (PAT) applications. It is also congruent with process digitalization and automation industry 4.0 concepts underpinned by Quality by Design (QbD) principles.


Assuntos
Proteínas , Tecnologia Farmacêutica , Controle de Qualidade
16.
J Pharm Sci ; 113(4): 1020-1028, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37839611

RESUMO

Process Analytical Technology (PAT) plays a crucial role in the design of today's manufacturing lines as continuous manufacturing becomes more important. Until now PAT tools to measure the ribbon solid fraction (SFribbon) in-line are not commonly used in roll compaction. The aim of this study was therefore to establish a new approach as PAT for in-line ribbon solid fraction determination. Different placebo formulations with different binders and one formulation containing active pharmaceutical ingredient were investigated using in-line laser triangulation measurement to detect the ribbon thickness after compaction. With this the ribbon elastic recovery was determined in-line (ERin-line) while the ribbons are attached to the roll surface. It was found that the ratio (ERratio) between the total elastic recovery and ERin-line is formulation specific and not influenced by any process parameters. This enables ERratio as prediction tool for SFribbon, if the solid fraction at gap (SFgap) width is known. SFgap was determined with ribbon mass flow measurement or based on the Midoux model, a simplified Johanson model, gaining two prediction models for SFribbon. Both models showed good agreement of the predicted SFribbon and the measured one.


Assuntos
Lasers , Tecnologia Farmacêutica , Composição de Medicamentos , Comprimidos , Pós , Tamanho da Partícula
17.
Anal Bioanal Chem ; 416(2): 373-386, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37946036

RESUMO

Continuous manufacturing is becoming increasingly important in the (bio-)pharmaceutical industry, as more product can be produced in less time and at lower costs. In this context, there is a need for powerful continuous analytical tools. Many established off-line analytical methods, such as mass spectrometry (MS), are hardly considered for process analytical technology (PAT) applications in biopharmaceutical processes, as they are limited to at-line analysis due to the required sample preparation and the associated complexity, although they would provide a suitable technique for the assessment of a wide range of quality attributes. In this study, we investigated the applicability of a recently developed micro simulated moving bed chromatography system (µSMB) for continuous on-line sample preparation for MS. As a test case, we demonstrate the continuous on-line MS measurement of a protein solution (myoglobin) containing Tris buffer, which interferes with ESI-MS measurements, by continuously exchanging this buffer with a volatile ammonium acetate buffer suitable for MS measurements. The integration of the µSMB significantly increases MS sensitivity by removing over 98% of the buffer substances. Thus, this study demonstrates the feasibility of on-line µSMB-MS, providing a versatile PAT tool by combining the detection power of MS for various product attributes with all the advantages of continuous on-line analytics.

18.
Biotechnol Prog ; 40(2): e3410, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38013663

RESUMO

An important consideration for biopharmaceutical processes is the cost of goods (CoGs) of biotherapeutics manufacturing. CoGs can be reduced by dramatically increasing the productivity of the bioreactor process. In this study, we demonstrate that an intensified process which couples a perfused N-1 seed reactor and a fully automated high inoculation density (HID) N stage reactor substantially increases the bioreactor productivity as compared to a low inoculation density (LID) control fed-batch process. A panel of six CHOK1SV GS-KO® CHO cell lines expressing three different monoclonal antibodies was evaluated in this intensified process, achieving an average 85% titer increase and 132% space-time yield (STY) increase was demonstrated when comparing the 12-day HID process to a 15-day LID control process. These productivity increases were enabled by automated nutrient feeding in both the N-1 and N stage bioreactors using in-line process analytical technologies (PAT) and feedback control. The N-1 bioreactor utilized in-line capacitance to automatically feed the bioreactor based on a capacitance-specific perfusion rate (CapSPR). The N-stage bioreactor utilized in-line Raman spectroscopy to estimate real-time concentrations of glucose, phenylalanine, and methionine, which are held to target set points using automatic feed additions. These automated feeding methodologies were shown to be generalizable across six cell lines with diverse feed requirements. We show this new process can accommodate clonal diversity and reproducibly achieve substantial titer uplifts compared to traditional cell culture processes, thereby establishing a baseline technology platform upon which further increases bioreactor productivity and CoGs reduction can be achieved.


Assuntos
Anticorpos Monoclonais , Reatores Biológicos , Cricetinae , Animais , Cricetulus , Células CHO , Anticorpos Monoclonais/metabolismo , Perfusão , Técnicas de Cultura Celular por Lotes/métodos
19.
Pharm Res ; 41(2): 375-385, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38114802

RESUMO

PURPOSE: This study is focused on monitoring process parameters and quality attributes of aluminum phosphate (AlPO4) using multiple in-line probes incorporated into an industrial-scale adjuvant suspension manufacturing unit. METHODS: The manufacturing of aluminum adjuvant suspension was monitored at manufacturing scale using conductivity, turbidity, infrared, and particle sizing and count probes to follow the continuous evolution of particle formation and size distribution, and the reaction kinetics during the synthesis of AlPO4. RESULTS: The data showed that AlPO4 forms large particles at the early stages of mixing, followed by a decrease in size and then stabilization towards the later stages of mixing and pH adjustment. The results provided a complementary view of process events and assisted in optimizing several parameters, e.g., flow rate of reactants AlCl3 and Na3PO4 solutions, mixing rate, pH, and conductivity of AlPO4, as well as adjuvant quality attribute such as particle size, thus streamlining and shortening the process development stage. CONCLUSION: The results of this study showed the usefulness of the in-line probes to automate continuous assessment of AlPO4 batch-to-batch consistency during in-house adjuvant production at the industrial scale.


Assuntos
Adjuvantes Imunológicos , Compostos de Alumínio , Fosfatos , Tamanho da Partícula , Tecnologia Farmacêutica/métodos
20.
Viruses ; 15(10)2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37896790

RESUMO

Yellow Fever (YF) is a severe disease that, while preventable through vaccination, lacks rapid intervention options for those already infected. There is an urgent need for passive immunization techniques using YF-virus-like particles (YF-VLPs). To address this, we successfully established a bioreactor-based production process for YF-VLPs, leveraging transient transfection and integrating Process Analytical Technology. A cornerstone of this approach was the optimization of plasmid DNA (pDNA) production to a yield of 11 mg/L using design of experiments. Glucose, NaCl, yeast extract, and a phosphate buffer showed significant influence on specific pDNA yield. The preliminary work for VLP-production in bioreactor showed adjustments to the HEK cell density, the polyplex formation duration, and medium exchanges effectively elevated transfection efficiencies. The additive Pluronic F-68 was neutral in its effects, and anti-clumping agents (ACA) adversely affected the transfection process. Finally, we established the stirred-tank bioreactor process with integrated dielectric spectroscopy, which gave real-time insight in relevant process steps, e.g., cell growth, polyplex uptake, and harvest time. We confirmed the presence and integrity of YF-VLP via Western blot, imaging flow cytometry measurement, and transmission electron microscopy. The YF-VLP production process can serve as a platform to produce VLPs as passive immunizing agents against other neglected tropical diseases.


Assuntos
Febre Amarela , Vírus da Febre Amarela , Humanos , Vírus da Febre Amarela/genética , Transfecção , Tecnologia , Reatores Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA