Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Geochem Health ; 46(6): 181, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695964

RESUMO

This study determined natural and artificial radionuclide concentrations to evaluate natural radioactivity and health risk levels of nine travertines in the Yaprakhisar and Balkayasi regions in Turkey. The samples coded B1-M, B2, B5, B7, B8, and B10 represent waste derived from the Yaprakhisar travertines, as well as samples T5-M, T12, and Z1 travertines derived from Balkayasi. The levels of natural and artificial radionuclide concentrations (232Th, 40K, and 137Cs) were measured using a high-purity germanium (HpGe) detector system. The travertine activity ranged from 2.09 to 12.07 Bq kg-1 for 232Th, 4.21 to 13.41 Bq kg-1 for 40K, and 0.42-3.26 Bq kg-1 for 137Cs. The results showed that the activity concentration values for 232Th, 40K, and 137Cs were coherent with the travertine analysis results in the UNSCEAR, 2000; 2008 publications. The values obtained were lower than the average values in the UNSEAR reports. The radiological hazard parameters calculated in this study were absorbed gamma dose rate (D), radium equivalent activity (Raeq), annual gonadal dose equivalent (AGDE), exposure dose (ER), total annual effective dose (AEDEtotal), excess lifetime cancer risk (ELCRtotal), gamma representative level (GRL), internal hazard index (Hin) and external hazard index (Hex).


Assuntos
Radioisótopos de Césio , Radioisótopos de Potássio , Monitoramento de Radiação , Turquia , Monitoramento de Radiação/métodos , Radioisótopos de Potássio/análise , Radioisótopos de Césio/análise , Tório/análise , Poluentes Radioativos do Solo/análise , Radiação de Fundo , Humanos , Medição de Risco
2.
Curr Med Imaging ; 19(9): 977-994, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36733238

RESUMO

BACKGROUND: Cone Beam Computed Tomography (CBCT) represents the optimal imaging solution for the evaluation of the maxillofacial and dental area when quantitative geometric and volumetric accuracy is necessary (e.g., in implantology and orthodontics). Moreover, in recent years, this technique has given excellent results for the imaging of lower and upper extremities. Therefore, significant interest has been increased in using CBCT to investigate larger and non-traditional anatomical districts. OBJECTIVE: The purpose of this work is to review the scientific literature in Pubmed and Scopus on CBCT application beyond head districts by paying attention to image quality and radiological doses. METHODS: The search for keywords was conducted in Pubmed and Scopus databases with no back-date restriction. Papers on applications of CBCT to head were excluded from the present work. From each considered paper, parameters related to image quality and radiological dose were extracted. An overall qualitative evaluation of the results extracted from each issue was done by comparing the conclusive remarks of each author regarding doses and image quality. PRISMA statements were followed during this process. RESULTS: The review retrieved 97 issues from 83 extracted papers; 46 issues presented a comparison between CBCT and Multi-Detector Computed Tomography (MDCT), and 51 reviewed only CBCT. The radiological doses given to the patient with CBCT were considered acceptable in 91% of cases, and the final image quality was found in 99%. CONCLUSION: CBCT represents a promising technology not only for imaging of the head and upper and lower extremities but for all the orthopedic districts. Moreover, the application of CBCT derived from C-arms (without the possibility of a 360 ° rotation range) during invasive investigations demonstrates the feasibility of this technique for non-standard anatomical areas, from soft tissues to vascular beds, despite the limits due to the incomplete rotation of the tube.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Multidetectores , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos
3.
J Interv Card Electrophysiol ; 64(3): 629-639, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34757547

RESUMO

PURPOSE: There is growing interest in performing fluoroless radiofrequency ablation (RFA) for atrial fibrillation (AF) due to the increasing awareness of risk associated with radiation exposure of patients and professional staff. The present study aimed to evaluate the feasibility, safety, and efficacy of a stepwise transesophageal echocardiography (TEE)-guided zero-fluoroscopy approach (ZFA) for RFA. METHODS: Consecutive patients (n = 111) referred for AF-ablation were prospectively enrolled with intention to RFA with ZFA. Procedural outcomes were compared with historical controls (HCs) after 1:1 propensity score matching. ZFA success was considered when no X-ray was utilized to perform the whole procedure. RESULTS: ZFA success was achieved in 80 (72%) procedures. BMI > 35 kg/m2 resulted in the only independent predictor of ZFA failure (OR = 6.10, 95% CI 1.15-46.49, p = 0.04). In comparison to HCs, a significant reduction in radiation exposure was observed in the ZFA group: fluoroscopy time (3 vs. 63 s, p < 0.001), total emitted fluoroscopy dose (0.2 vs. 6.0 mGy, p < 0.001), dose area product (0.04 vs. 1.4 Gy*cm2, p < 0.001), and effective dose (0.8 vs. 27.2 mSv*100, p < 0.001). Complete pulmonary vein isolation was achieved in all procedures. No difference was observed between the groups in in-hospital complication rate (0.9% vs. 1.8%, p = 0.99). CONCLUSIONS: This is the largest study proving procedural feasibility, safety, and efficacy of TEE-guided AF-ablation with a complete or near-complete avoidance of radiological exposure, without using intracardiac echocardiography.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia Transesofagiana , Fluoroscopia/métodos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
4.
J Interv Card Electrophysiol ; 60(3): 477-484, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32405889

RESUMO

BACKGROUND: Cardiac computed tomography (CT) is commonly used to study left atrial (LA) and pulmonary veins (PVs) anatomy before atrial fibrillation (AF) ablation. The aim of the study was to determine the impact of pre-procedural cardiac CT with 3D reconstruction on procedural outcomes and radiological exposure in patients who underwent radiofrequency catheter ablation (RFA) of AF. METHODS: In this registry, 493 consecutive patients (age 62 ± 8 years, 70% male) with paroxysmal (316) or persistent (177) AF who underwent first procedure of RFA were included. A pre-procedural CT scan was obtained in 324 patients (CT group). Antral pulmonary vein isolation was performed in all patients using an open-irrigation-tip catheter with a 3D electroanatomical navigation system. Procedural outcome, including radiological exposure, and clinical outcomes were compared among patients who underwent RFA with (CT group) and without (no CT group) pre-procedural cardiac CT. RESULTS: Acute PV isolation was obtained in all patients, with a comparable overall complication rate between CT and no CT group (4.3% vs 3%, p = 0.7). No differences were observed about mean duration of the procedure (231 ± 60 vs 233 ± 58 min, p = 0.7) and fluoroscopy time (13 ± 10 vs 13 ± 8 min, p = 0.6) among groups. Cumulative radiation dose resulted significantly higher in the CT group compared with no CT group (8.9 ± 24 vs 4.8 ± 15 mSv, P = 0.02). At 1 year, freedom from AF/atrial tachycardia were comparable among groups (CT group, 227/324 (70%), vs no CT group,119/169 (70%), p = ns). CONCLUSIONS: Pre-procedural CT does not improve safety and efficacy of AF ablation, increasing significantly the cumulative radiological exposure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Feminino , Humanos , Recém-Nascido , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
Int J Cardiovasc Imaging ; 36(9): 1599-1607, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32447632

RESUMO

To evaluate predictors of zero-X ray procedures for supraventricular arrhythmias (SVT) using minimally fluoroscopic approach (MFA). Patients referred for RF catheter ablation of SVT were admitted for a MFA with an electro-anatomical navigation system or a conventional fluoroscopic approach (ConvA). Exclusion criterion was the need to perform a transseptal puncture. 206 patients (98 men, age 53 ± 19 years) underwent an EP study, 93 (45%) with an MFA and 113 (55%) with a ConvA. Fifty-five had no inducible arrhythmias (EPS). Fifty-four had AV nodal reentrant tachycardia (AVNRT), 49 patients had typical atrial flutter (AFL), 37 had AV reciprocating tachycardia (AVRT/WPW), 11 had focal atrial tachycardia (AT), and underwent a RF ablation. X-ray was not used at all in 51/93 (58%) procedures (zero X ray). MFA was associated with a significant reduction in total fluoroscopy time (5.5 ± 10 vs 13 ± 18 min, P = 0.01) and operator radiation dose (0.8 ± 2.5 vs 3 ± 8.2 mSV, P < 0.05). The greatest absolute dose reduction was observed in AVNRT (0.1 ± 0.3 vs 5.1 ± 10 mSV, P = 0.01, 98% relative dose reduction) and in AFL (1.3 ± 3.6 vs 11 ± 16 mSV, P = 0.003, 88% relative dose reduction) groups. Both AVNRT or AFL resulted the only statistically significant predictors of zero x ray at multivariate analysis (OR 4.5, 95% CI 1.5-13 and OR 5, 95% CI 1.7-15, P < 0.001, respectively). Success and complication rate was comparable between groups (P = NS). Using MFA for SVT ablation, radiological exposure is significantly reduced. Type of arrhythmia is the strongest predictor of zero X ray procedure.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fluoroscopia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional/efeitos adversos , Segurança do Paciente , Exposição à Radiação/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
Appl Radiat Isot ; 81: 190-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23602586

RESUMO

The UAE has started a nuclear energy program with the aim of having its first four units on-line between 2017 and 2020 and it is important that the country has an environmental radiation analysis capability to support this program. Khalifa University is therefore implementing a research laboratory to support both experimental analysis and radionuclide transport modeling in the aquatic and terrestrial environment. This paper outlines the development of this capability as well as the work in progress and planned for the future.


Assuntos
Programas Governamentais/organização & administração , Física Nuclear/organização & administração , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Pesquisa/organização & administração , Emirados Árabes Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA