Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.225
Filtrar
1.
Radiat Oncol ; 19(1): 103, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095859

RESUMO

Breast conserving treatment typically involves surgical excision of tumor and adjuvant radiotherapy targeting the breast area or tumor bed. Accurately defining the tumor bed is challenging and lead to irradiation of greater volume of healthy tissues. Preoperative stereotactic body radiotherapy (SBRT) which target tumor may solves that issues. We conducted a systematic literature review to evaluates the early toxicity and cosmetic outcomes of this promising treatment approach. Secondary we reviewed pathological complete response (pCR) rates, late toxicity, patient selection criteria and radiotherapy protocols. We retrieved literature from PubMed, Scopus, Web of Science, Cochrane, ScienceDirect, and ClinicalTrials.gov. The study adhered to the PRISMA 2020 guidelines. Ten prospective clinical trials (7 phase II, 3 phase I), encompassing 188 patients (aged 18-75 years, cT1-T3 cN0-N3 cM0, primarily with ER/PgR-positive, HER2-negative status,), were analyzed. Median follow-up was 15 months (range 3-30). Treatment involved single-fraction SBRT (15-21Gy) in five studies and fractionated (19.5-31.5Gy in 3 fractions) in the rest. Time interval from SBRT to surgery was 9.5 weeks (range 1-28). Acute and late G2 toxicity occurred in 0-17% and 0-19% of patients, respectively, G3 toxicity was rarely observed. The cosmetic outcome was excellent in 85-100%, fair in 0-10% and poor in only 1 patient. pCR varied, showing higher rates (up to 42%) with longer intervals between SBRT and surgery and when combined with neoadjuvant systemic therapy (up to 90%). Preoperative SBRT significantly reduce overall treatment time, enabling to minimalize volumes. Early results indicate excellent cosmetic effects and low toxicity.


Assuntos
Neoplasias da Mama , Radiocirurgia , Humanos , Radiocirurgia/métodos , Radiocirurgia/efeitos adversos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Feminino , Cuidados Pré-Operatórios
2.
J Med Phys ; 49(2): 213-224, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39131419

RESUMO

Purpose: To show the workflow for the commissioning of a MRlinac, and some proposed tests; off-axis targets, output factors for small fields, dose in inhomogeneities, and multileaf collimator quality assurance (MLC QA). Methods: The tests were performed based on TG-142, TG-119, ICRU 97, TRS-398, and TRS-483 recommendations as well as national regulations for radiation protection and safety. Results: The imaging tests are in agreement with the protocols. The radiation isocenter was 0.34 mm, and for off-axis targets location was up to 0.88 mm. The dose profiles measured and calculated in treatment planning system (TPS) passed in all cases the gamma analysis of 2%/2 mm (global dose differences). The output factors of fields larger than 2 cm × 2 cm are in agreement with the model of the MRlinac in the TPS. However, for smaller fields, their differences are higher than 10%. Picket fence test for different gantry angles showed a maximum leaf deviation up to 0.2 mm. Displacements observed in treatment couch adding weight (50 kg) are lower than 1 mm. Cryostat, bridge, and couch attenuation was up to 1.2%, 10%, and 24%, respectively. Conclusion: The implemented tests confirm that the studied MRlinac agrees with the standards reported in the literature and that the strict tolerances established as a baseline should allow a smoother implementation of stereotactic treatments in this machine.

3.
J Med Imaging Radiat Sci ; 55(4): 101729, 2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39128321

RESUMO

PURPOSE: To construct a tumor motion monitoring model for stereotactic body radiation therapy (SBRT) of lung cancer from a feasibility perspective. METHODS: A total of 32 treatment plans for 22 patients were collected, whose planning CT and the centroid position of the planning target volume (PTV) were used as the reference. Images of different respiratory phases in 4DCT were acquired to redefine the targets and obtain the floating PTV centroid positions. In accordance with the planning CT and CBCT registration parameters, data augmentation was accomplished, yielding 2130 experimental recordings for analysis. We employed a stacking multi-learning ensemble approach to fit the 3D point cloud variations of body surface and the change of target position to construct the tumor motion monitoring model, and the prediction accuracy was assess using root mean squared error (RMSE) and R-Square (R2). RESULTS: The prediction displacement of the stacking ensemble model shows a high degree of agreement with the reference value in each direction. In the first layer of model, the X direction (RMSE =0.019 ∼ 0.145mm, R2 =0.9793∼0.9996) and the Z direction (RMSE = 0.051 ∼ 0.168 mm, R2 = 0.9736∼0.9976) show the best results, while the Y direction ranked behind (RMSE = 0.088 ∼ 0.224 mm, R2 = 0.9553∼ 0.9933). The second layer model summarizes the advantages of unit models of first layer, and RMSE of 0.015 mm, 0.083 mm, 0.041 mm, and R2 of 0.9998, 0.9931, 0.9984 respectively for X, Y, Z were obtained. CONCLUSIONS: The tumor motion monitoring method for SBRT of lung cancer has potential application of non-ionization, non-invasive, markerless, and real-time.

4.
Radiother Oncol ; 199: 110466, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39094630

RESUMO

AIM: To evaluate acute toxicity at 6 months after stereotactic body radiotherapy (SBRT) in patients with oligometastatic cancer within the OligoCare cohort. MATERIAL AND METHODS: OligoCare is a prospective, registry-based, single-arm, observational study that aims to report prospective real-world data of patients with oligometastases from solid cancer treated with SBRT (NCT03818503). Primary tumor included non-small cell lung cancer (NSCLC), breast cancer (BC), colorectal cancer (CRC), and prostate cancer (PC). This analysis addresses a secondary endpoint of the trial, acute toxicity within 6 months after SBRT. RESULTS: Out of 1,597registered patients, 1'468 patients were evaluated for acute toxicity. Globally, 290 (20 %) had NSCLC primary disease, 227 (16 %) had BC, 293 (20 %) had CRC, and 658 (45 %) had PC. Concomitant systemic treatment was administered in 527 (35.9 %) patients. According to the EORTC/ESTRO oligometastatic disease (OMD) classification, 828 (56 %) patients had de novo OMD, 464 (32 %) repeat OMD, and 176 (12 %) induced OMD. Acute grade ≥ 3 SBRT related adverse events were reported in 8 (0.5 %) patients, including 2 (0.1 %) fatal AEs. In particular, 6 (0.4 %) grade 3 events were: 1 empyema, 1 pneumonia, 1 radiation pneumonitis, 1 radiation skin injury, 1 decreased appetite, and 1 bone pain. Among those 2 occurred in NSCLC patients, 2 in BC patients, and 1 in CRC and PC patients each. The two (0.1 %) grade 5 toxicity were represented by: pneumonitis and cerebral hemorrhage. CONCLUSION: OligoCare is the largest prospective registry cohort on oligometastatic disease. Acute toxicity within 6 months was low, confirming the safety of SBRT in the treatment of oligometastases.

5.
Clin Transl Radiat Oncol ; 48: 100813, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39149753

RESUMO

Purpose/Objectives: Retrospective analysis suggests that dose escalation to a biologically effective dose of more than 70 Gy may improve overall survival in patients with pancreatic ductal adenocarcinoma (PDAC), but such treatments in practice are limited by proximity of organs at risk (OARs). We hypothesized that CT-guided online adaptive radiotherapy (OART) can account for interfraction movement of OARs and allow for safe delivery of ablative doses. Materials/Methods: This is a single institution retrospective analysis of patients with PDAC treated with OART on the Ethos platform (Varian Medical Systems, a Siemens Healthineers Company, Palo Alto). All patients were treated to 40 Gy in 5 fractions. PTV overlapping with a 5 mm planning risk volume expansion on the stomach, duodenum and bowel received 25 Gy. Initial treatment plans were created conventionally. For each fraction, PTV and OAR volumes were recontoured with AI assistance after initial cone beam CT (CBCT). The adapted plan was calculated, underwent QA, and then compared to the scheduled plan. A second CBCT was obtained prior to delivery of the selected plan. Total treatment time (first CBCT to end of radiation delivery) and active physician time (first to second CBCT) were recorded. PTV_4000 V95 %, PTV_2500 V9 5%, and D0.03 cc to stomach, duodenum and bowel were reported for scheduled (S) and adapted (A) plans. CTCAEv5.0 toxicities were recorded. Statistical analysis was performed using a two-sided T test and α of 0.05. Results: 21 patients with unresectable or locally-recurrent PDAC were analyzed, with a total of 105 fractions. Average total time was 29 min and 16 s (16:36-49:40) and average active physician time was 19:41 min (9:25-39:34). All fractions were treated with adapted plans. 97 % of adapted plans met PTV_4000 V95.0 % >95.0 % coverage goal and 100 % of adapted plans met OAR dose constraints. Median follow up was 6.6 months. Only 1 patient experienced acute grade 3+ toxicity directly attributable to radiation. Only 1 patient experienced late grade 3+ toxicity directly attributable to radiation. Conclusions: Daily CT-based OART was associated with significantly reduced dose OARs while achieving superior PTV coverage. Given the relatively quick total treatment time, radiation delivery was generally well tolerated and easily incorporated into the clinic workflow. Our initial clinical experience demonstrates OART allows for safe dose escalation in the treatment of PDAC.

6.
Cancers (Basel) ; 16(15)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39123406

RESUMO

Renal cell cancer (RCC) has traditionally been considered radioresistant. Because of this, conventional radiotherapy (RT) has been predominantly relegated to the palliation of symptomatic metastatic disease. The implementation of stereotactic ablative radiotherapy (SABR) has made it possible to deliver higher ablative doses safely, shifting the renal radioresistance paradigm. SABR has increasingly been adopted into the multidisciplinary framework for the treatment of locally recurrent, oligoprogressive, and oligometastatic disease. Furthermore, there is growing evidence of SABR as a non-invasive definitive therapy in patients with primary RCC who are medically inoperable or who decline surgery, unsuited to invasive ablation (surgery or percutaneous techniques), or at high-risk of requiring post-operative dialysis. Encouraging outcomes have even been reported in cases of solitary kidney or pre-existing chronic disease (poor eGFR), with a high likelihood of preserving renal function. A review of clinical evidence supporting the use of ablative radiotherapy (SABR) in primary, recurrent, and metastatic RCC has been conducted. Given the potential immunogenic effect of the high RT doses, we also explore emerging opportunities to combine SABR with systemic treatments. In addition, we explore future directions and ongoing clinical trials in the evolving landscape of this disease.

7.
Cancers (Basel) ; 16(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39123438

RESUMO

Compared with computed tomography (CT), magnetic resonance imaging (MRI) traditionally plays a very limited role in lung cancer management, although there is plenty of room for improvement in the current CT-based workflow, for example, in structures such as the brachial plexus and chest wall invasion, which are difficult to visualize with CT alone. Furthermore, in the treatment of high-risk tumors such as ultracentral lung cancer, treatment-associated toxicity currently still outweighs its benefits. The advent of MR-Linac, an MRI-guided radiotherapy (RT) that combines MRI with a linear accelerator, could potentially address these limitations. Compared with CT-based technologies, MR-Linac could offer superior soft tissue visualization, daily adaptive capability, real-time target tracking, and an early assessment of treatment response. Clinically, it could be especially advantageous in the treatment of central/ultracentral lung cancer, early-stage lung cancer, and locally advanced lung cancer. Increasing demands for stereotactic body radiotherapy (SBRT) for lung cancer have led to MR-Linac adoption in some cancer centers. In this review, a broad overview of the latest research on imaging-guided radiotherapy (IGRT) with MR-Linac for lung cancer management is provided, and development pertaining to artificial intelligence is also highlighted. New avenues of research are also discussed.

10.
J Radiosurg SBRT ; 9(2): 121-128, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39087059

RESUMO

Purpose: To review our initial experience with proton-based SBRT to evaluate the planning outcomes and initial patient tolerance of treatment. Patients and methods: From Sep. 2019 to Dec. 2020, 52 patients were treated with proton SBRT to 62 lesions. Fractionation varied by indication and site with a median of 5 fractions and median fractional dose of 8 Gy. Planning outcomes, including plan heterogeneity, conformity, and PTV volume receiving 100% of the prescription dose (PTV V100%) were evaluated. Acute toxicities were prospectively recorded, and patient reported outcomes were assessed prior to and at completion of treatment using the MD Anderson Symptom Inventory (MDASI) and EQ-5D5L visual analogue score (VAS). Results: All treated patients completed their course of proton-based SBRT. The mean conformity index was 1.05 (range 0.51-1.48). R50% values were comparable to ideal photon parameters. PTV V100% was 89.9% on average (40.44% - 99.76%). 5 patients (10%) required plan modification due to setup or tumor changes. No patients developed a new grade 3 or greater toxicity during treatment. Comparing pretreatment to end of treatment timepoints, there was a significant improvement in the mean VAS (65 to 75, p = 0.014), with no significant change in the mean MDASI symptom (1.7, 1.8; p = 0.79) or interference (2.3, 2.4; p = 0.452) scores. Conclusion: Proton-based SBRT can achieve dosimetric goals required by major clinical photon trials. It was well-tolerated with no decrement in patient reported outcomes and a mean 10-point improvement in VAS at the conclusion of SBRT. Further follow-up is necessary for tumor control and late effects analysis.

12.
Tumori ; : 3008916241261450, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39096026

RESUMO

PURPOSE: Quality assurance for stereotactic body radiation treatment requires that isocentric verification be ensured during gantry rotation at various angles. This study examined statistical parameters on Winston-Lutz tests to distinguish the deviation of angles from isocenter during gantry rotation using machine learning. METHOD: The Varian TrueBeam linac was aligned with the marked lines on the Ruby phantom. Eight images were captured while the gantry was rotating at a 45° shift. The statistical features were derived from IsoCheck EPID software. The decision tree model was applied to these Winston-Lutz tests to cluster data into two groups: precise and error angles. RESULTS: At 90° and 270° angles, the gantry exhibits isocentric stability compared to other angles. In these angles, the most statistical features were inside the range. Most variations were observed at 0° and 180° angles. In most tests, the angles 45°, 135°, 225°, and 315° showed reasonable performance and with less variation. CONCLUSION: The comprehensive statistical analyses for gantry rotation of angles assists expert radiotherapists in determining the contribution of each feature that highly affects gantry movement at specific angles. Misalignment between radiation isocenter and imaging isocenter, tuning of the beam at each angle, or a slight change in the position of the Ruby phantom can further improve the inaccuracy that causes the most variations. Better precision can effectively increase patient safety and quality during cancer treatment.

13.
Artigo em Inglês | MEDLINE | ID: mdl-39122095

RESUMO

BACKGROUND AND PURPOSE: STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia (VT). However, clinical data is scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization. METHODS: Planning target volumes (PTV) overlapping extra-cardiac organs-at-risk and/or cardiac substructures were generated for three STAR cases. Participating centers were asked to create single fraction treatment plans with 25 Gy dose prescription based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for ICRU report 91 relevant parameters and crowd dose-volume-histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process. RESULTS: Twenty centers submitted 67 treatment plans for this study. In most plans (75%) Intensity Modulated Arc Therapy (IMAT) with 6 MV flattening-filter-free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96-100% (19%). Many participants preferred to spare close extra-cardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged 25.5-34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged 2-80 minutes. For the consensus statements, strong agreement was reached for beam technique planning, dose calculation, prescription methods and trade-offs between target and extra-cardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target. CONCLUSION: This STOPSTORM multi-center treatment planning benchmark study showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established, however clinical data is urgently needed for actionable guidelines for treatment planning.

14.
Cureus ; 16(6): e62906, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39040774

RESUMO

Stereotactic body radiotherapy (SBRT) to the central and ultra-central thorax is associated with infrequent but potentially serious adverse events. Adaptive SBRT, which provides more precise treatment planning and inter-fraction motion management, may allow the delivery of ablative doses to ultra-central tumors with effective local control and improved toxicity profiles. Herein, we describe the first reported case of cone beam computed tomography (CBCT)-guided stereotactic adaptive radiotherapy (CT-STAR) in the treatment of ultra-central non-small cell lung cancer (NSCLC) in a prospective clinical trial (NCT05785845). An 80-year-old man with radiographically diagnosed early-stage NSCLC presented for definitive management of an enlarging ultra-central lung nodule. He was prescribed 55 Gy in five fractions with CT-STAR. A simulation was performed using four-dimensional CT, and patients were planned for treatment at end-exhale breath-hold. Treatment plans were generated using a strict isotoxicity approach, which prioritized organ at risk (OAR) constraints over target coverage. During treatment, daily CBCTs were acquired and used to generate adapted contours and treatment plans based on the patient's anatomy-of-the-day, all while the patient was on the treatment table. The initial and adapted plans were compared using dose-volume histograms, and the superior plan was selected for treatment. The adapted plan was deemed superior and used for treatment in three out of five fractions. The adapted plan provided improved target coverage in two fractions and resolved an OAR hard constraint violation in one fraction. We report the successful treatment of a patient with ultra-central NSCLC utilizing CT-STAR. This case report builds on previously published in silico data to support the viability and dosimetric advantages of CT-STAR in the ablative treatment of this challenging tumor location. Further data are needed to confirm the toxicity and efficacy of this technique.

15.
J Neurooncol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046598

RESUMO

PURPOSE: This study aimed to identify factors associated with local recurrence after spinal stereotactic body radiation therapy (SBRT), focusing on patient movement during treatment and tumor characteristics. METHODS: A total of 48 patients who underwent spinal SBRT alone without surgery from August 2017 to October 2022 were evaluated. Logistic regression analysis was conducted to identify factors associated with local recurrence, including patient movement and tumor characteristics such as soft tissue involvement and tumor volume. Patient movement during treatment was measured using cone beam computed tomography before and after irradiation. RESULTS: Among the included cases, 68.7% and 42.6% had soft tissue involvement and movement exceeding 1 mm, respectively. The median follow-up duration for local recurrence was 11.6 (range: 0.7-44.9) months, whereas the median duration to local recurrence was 6.3 months. Within 12 months, 29.3% of the patients experienced local recurrence, among whom 43.9% moved ≥ 1 mm during treatment, whereas 15.8% did not move. Univariable analysis found that both soft tissue involvement (OR = 10.3, 1.21-87.9; p = 0.033) and patient movement ≥ 1 mm (OR = 5.75, 1.45-22.8; p = 0.013) were associated with local recurrence. Multivariable analysis identified patient movement as an independent prognostic factor for local recurrence (OR = 5.15, 1.06-25.0; p = 0.042). CONCLUSION: Our results suggest that patient movement during spinal SBRT was associated with local recurrence, emphasizing the need for better immobilization techniques and shorter delivery times to improve tumor control.

16.
Pract Radiat Oncol ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39047905

RESUMO

This report details a pharyngeal constrictor muscle (PCM)-sparing stereotactic body radiation therapy (SBRT) using our institutional technique of "Tongue-out" RT (TORT) for treating a local recurrent cancer in the uvula (GTVuvula) in a patient with history of a definitive chemo-RT (70 Gy with weekly cisplatin) for a locally advanced laryngeal cancer four years ago. TORT includes optimizing the patients' reproducible tongue-out position using readily available medicine cup (30 cc) followed by sculping the thermoplastic mask with tongue-out, and real-time visual monitoring of the tongue position during the CT-simulation scan, CBCT acquisition, and treatment. Between arcs during volumetric modulated arc therapy (VMAT), time for tongue relaxation and saliva swallowing can be given to the patient. Without TORT, the patient's GTVuvula abutted the medial aspect of superior PCM (medial-sPCM) and a substantial volume of the previously irradiated sPCM would have received high radiation dose from this salvage SBRT (32.5 Gy in 5 fractions). Compared to without TORT, the shortest distance between medial-sPCM-to-GTVuvula was increased by 13 mm with TORT, which reduced radiation dose to sPCM in salvage SBRT plan. The mean dose (Dmean) to sPCM was decreased from 20.5 Gy without TORT to 12.7 Gy with TORT. With TORT, minimal sPCM volumes fell within higher isodose line: volume receiving ≥ 60% prescription dose (V60%Rx), V80%Rx, and V100%Rx to sPCM was, 4.8 vs. 0.7 cc (without vs. with TORT, respectively), 2.9 vs. 0.19 cc, and 1.6 vs. 0.04 cc, respectively. Maximum dose (Dmax) to medial-sPCM was 34.6 Gy without TORT vs. 22.7 Gy with TORT. These high doses to the sPCM and intrafractional swallowing-related geographic misses of GTVuvula were avoided through the application of TORT in this salvage re-RT setting. The patient successfully finished salvage SBRT with TORT resulting no dysphagia or mucositis and maintained complete response at 12 months after treatment.

17.
Eur J Cancer ; 209: 114233, 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39053290

RESUMO

OBJECTIVE: Harmonized European NSCLC incidence, treatment approach, and survival based on national tumor registries are unclear. SUMMARY BACKGROUND DATA: Surgery has the potential to cure NSCLC and significantly prolong survival. This large-scale international study aimed to investigate treatment variations in Europe and the USA, as well as the determinants for its utilization. METHODS: The retrospective cohort study analyzed data from six European national population-based cancer registries (Belgium, Denmark, Estonia, Germany, the Netherlands, and Slovenia) and the US SEER database from 2010-2015. RESULTS: The study computed cancer incidence, survival, and age-standardized proportions of the use of various therapies. Multivariable logistic regression models were used to assess associations between resection and demographic and clinical parameters. A total of 428,107 records were analyzed. Among all countries, Estonia had the highest surgical resection rate (79.3 %) and the lowest radiation rate (7.3 %) for stage I patients. The Netherlands had the highest rate of radiotherapy across all years of investigation and the lowest surgery rate between 2012 and 2015. The primary treatment for early-stage NSCLC showed significant international variation, with the USA having a decrease in surgical rates from 67.6 % to 59.5 %. Resection was less frequently performed as tumor stage increased, patients aged, other lung cancer besides adenocarcinoma was present, and when the tumor site overlapped multiple lobes. CONCLUSIONS: Resection rates have declined in some studied European countries and the USA and resection rates vary substantially among countries. Interpretation of current scientific lung cancer evidence and international guidelines results in wide variations in patient treatment.

18.
Cureus ; 16(5): e61432, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38947568

RESUMO

PURPOSE: Stereotactic body radiation therapy (SBRT) has been established as a safe and effective treatment for prostate cancer. SBRT requires high accuracy to reduce treatment margins. Metal hip prostheses create artifacts that distort pelvic imaging and potentially decrease the accuracy of target/organ at risk (OAR) identification and radiation dose calculations. Data on the safety and efficacy of SBRT after hip replacement is limited. This single-institution study sought to evaluate the safety and local control following SBRT for prostate cancer in men with hip replacements. METHODS: 23 patients treated with localized prostate cancer and a history of pre-treatment hip replacement, treated with SBRT from 2007 to 2017 at MedStar Georgetown University Hospital were included in this retrospective analysis. Treatment was administered with the CyberKnife® (Accuray Incorporated, Sunnyvale, CA) at doses of 35 Gy or 36.25 Gy in 5 fractions. The targets and OARs were identified and contoured by a single experienced Radiation Oncologist (SPC). The adequacy of the CT and T2W MRI images for treatment planning was assessed with a three-point scale (good, adequate, or suboptimal). During treatment planning, care was taken to avoid treatment beams that directly traversed the hip prosthesis. Toxicities were recorded and scored using the Common Terminology Criteria for Adverse Events version 4.0 (CTCAE v.4.0). Local recurrence was confirmed by magnetic resonance imaging and/or prostate biopsy. RESULTS: The median follow-up was seven years. The patients were elderly (median age = 71 years) with a high rate of comorbidities (Charlson Comorbidity Index > 2 in 25%). Four patients had bilateral hip replacements. The majority of patients were low to intermediate risk per the D'Amico classification. Around 13% received upfront ADT. In total, 13 patients were treated with 35 Gy, and 10 were treated with 36.25 Gy. The rates of late > Grade 3 GU toxicity and > Grade 2 GI toxicity were 8.6% and 4.3%, respectively. There were no Grade 4 or 5 toxicities. Six patients (26%) developed a local recurrence at a median time of 7.5 years. Of these six patients, four had unilateral hip replacements and two had bilateral. Three underwent salvage cryotherapy and three received salvage ADT. CONCLUSIONS:  In the general population, high-grade toxicities and local recurrences are uncommon following prostate SBRT. However, in this cohort of patients with prior hip replacements, prostate SBRT had higher than expected rates of late toxicity and local recurrence. In the opinion of the authors, such patients should be counseled regarding an elevated risk of late toxicity and local recurrence with prostate SBRT. With its ultrasound guidance, brachytherapy would have the advantage of circumventing the need for MRI/CT-based imaging and thus may represent a preferable radiation alternative in this patient population. If these patients are treated with SBRT, they should be monitored closely for local recurrence so early salvage can be performed. We hope that recent advances in metal artifact reduction techniques and dose-calculation algorithms will improve future outcomes.

19.
J Appl Clin Med Phys ; : e14403, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38952067

RESUMO

PURPOSE: This study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam-off at specific gantry angles). METHODS: A total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference (DD) and relative value (DD%) were evaluated using the dose-volume histogram (DVH) metrics, planning target volume Dmax, D95%, spinal cord D0.035 cc, and esophagus D2.5 cc. The magnitude of the liver movements was evaluated based on differences of liver size Lave at the isocentric axial plane between the inspiratory and expiratory CT images. RESULTS: The DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean ± $ \pm $ a standard deviation (SD) DD in PTV D95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 ± $\pm$ 0.3 and 0.9 ± $ \pm $ 0.6 Gy, respectively. The spinal cord D0.035 cc for those shows 0.4 ± $ \pm $ 0.2 and 0.7 ± $ \pm $ 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between Lave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D0.035 cc revealed approximately 1 Gy or +4% in DD when Lave was < -4 cm. CONCLUSIONS: Respiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath-hold. Alternatively, beam avoidance effectively mitigates the impact.

20.
Med Dosim ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39013723

RESUMO

To compare the dosimetric differences in volumetric modulated arc therapy (VMAT) and intensity modulated proton therapy (IMPT) in stereotactic body radiation therapy (SBRT) of multiple lung lesions and determine a normal tissue complication probability (NTCP) model-based decision strategy that determines which treatment modality the patient will use. A total of 41 patients were retrospectively selected for this study. The number of patients with 1-6 lesions was 5, 16, 7, 6, 3, and 4, respectively. A prescription dose of 70 GyRBE in 10 fractions was given to each lesion. SBRT plans were generated using VMAT and IMPT. All the IMPT plans used robustness optimization with ± 3.5% range uncertainties and 5 mm setup uncertainties. Dosimetric metrics and the predicted NTCP value of radiation pneumonitis (RP), esophagitis, and pericarditis were analyzed to evaluate the potential clinical benefits between different planning groups. In addition, a threshold for the ratio of PTV to lungs (%) to determine whether a patient would benefit highly from IMPT was determined using receiver operating characteristic curves. All plans reached target coverage (V70GyRBE ≥ 95%). Compared with VMAT, IMPT resulted in a significantly lower dose of most thoracic normal tissues. For the 1-2, 3-4 and 5-6 lesion groups, the lung V5 was 29.90 ± 9.44%, 58.33 ± 13.35%, and 81.02 ± 5.91% for VMAT and 11.34 ± 3.11% (p < 0.001), 21.45 ± 3.80% (p < 0.001), and 32.48 ± 4.90% (p < 0.001) for IMPT, respectively. The lung V20 was 12.07 ± 4.94%, 25.57 ± 6.54%, and 43.99 ± 11.83% for VMAT and 6.76 ± 1.80% (p < 0.001), 13.14 ± 2.27% (p < 0.01), and 19.62 ± 3.48% (p < 0.01) for IMPT. The Dmean of the total lung was 7.65 ± 2.47 GyRBE, 14.78 ± 2.75 GyRBE, and 21.64 ± 4.07 GyRBE for VMAT and 3.69 ± 1.04 GyRBE (p < 0.001), 7.13 ± 1.41 GyRBE (p < 0.001), and 10.69 ± 1.81 GyRBE (p < 0.001) for IMPT. Additionally, in the VMAT group, the maximum NTCP value of radiation pneumonitis was 73.91%, whereas it was significantly lower in the IMPT group at 10.73%. The accuracy of our NTCP model-based decision model, which combines the number of lesions and PTV/Lungs (%), was 97.6%. The study demonstrated that the IMPT SBRT for multiple lung lesions had satisfactory dosimetry results, even when the number of lesions reached 6. The NTCP model-based decision strategy presented in our study could serve as an effective tool in clinical practice, aiding in the selection of the optimal treatment modality between VMAT and IMPT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA