Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiol Phys Technol ; 17(3): 782-792, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39028437

RESUMO

In normal-pressure hydrocephalus, disturbances in cerebrospinal fluid (CSF) circulation occur; therefore, understanding CSF dynamics is crucial. The two-dimensional phase-contrast (2D-PC) method, a common approach for visualizing CSF flow on MRI, often presents challenges owing to prominent vein signals and excessively high contrast, hindering the interpretation of morphological information. Therefore, we devised a new imaging method that utilizes T2-weighted high-signal intensification of the CSF and saturation pulses, without requiring specialized imaging sequences. This sequence utilized a T2-weighted single-shot fast spin-echo combined with multi-phase imaging synchronized with a pulse wave. Optimal imaging conditions (repetition time, presence/absence of fast recovery, and echo time) were determined using self-made contrast and single-plate phantoms to evaluate signal-to-noise ratio, contrast ratio, and spatial resolution. In certain clinical cases of hydrocephalus, confirming CSF flow using 2D-PC was challenging. However, our method enabled the visualization of CSF flow, proving to be useful in understanding the pathophysiology of hydrocephalus.


Assuntos
Líquido Cefalorraquidiano , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Líquido Cefalorraquidiano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/fisiopatologia , Masculino , Razão Sinal-Ruído , Feminino , Processamento de Imagem Assistida por Computador/métodos , Idoso
2.
NMR Biomed ; 36(5): e4875, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36357354

RESUMO

Earlier diagnosis of nonalcoholic fatty liver disease (NAFLD) is important to prevent progression of the disease. Recently, a low-cost portable magnetic resonance (MR) system was developed as a point-of-care screening tool for in vivo liver fat quantification. However, subcutaneous fat may confound the liver fat quantification, particularly in the NAFLD population. In this work, we propose a novel radiofrequency (RF) coil design composed of a set of "saturation" coils sandwiching a main coil to improve human liver fat quantification. By comparison with conventional MR imaging, we demonstrate the capability and effectiveness of the novel RF coil design in phantom experiments as well as in vivo liver scans. In the phantom experiment, the saturation coil reduced the error in the measured proton density fat fraction (PDFF) results from 28.9% to 4.0%, and in the in vivo experiment, it reduced the discrepancy in the PDFF results from 13.2% to 4.0%. The novel coil design, together with the adapted Carr-Purcell-Meiboom-Gill-based sequence, improves the practicability and robustness of the portable single-side MR system.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Fígado/diagnóstico por imagem , Fígado/patologia , Espectroscopia de Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/diagnóstico por imagem , Tecido Adiposo/patologia , Prótons
3.
Magn Reson Med Sci ; 22(4): 487-495, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36047248

RESUMO

PURPOSE: Amide proton transfer (APT) imaging may detect changes in tissues' pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. METHODS: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53-7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 µT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI each saturation pulse - APT SI shortest or weakest pulse)/APT SIshortest or weakest pulse. The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. RESULTS: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. CONCLUSION: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 µT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values.


Assuntos
Amidas , Prótons , Humanos , Imageamento por Ressonância Magnética/métodos , Albuminas , Concentração de Íons de Hidrogênio
4.
Magn Reson Imaging ; 94: 80-88, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36122676

RESUMO

To develop and validate a novel noncontrast time-resolved magnetic resonance angiography (NC TR-MRA) using consecutive beam pulses with variable flip angles for visualizing hemodynamics in the pulmonary artery, we performed phantom and volunteer studies and applied the novel NC TR-MRA to a 51-year-old woman with pulmonary arteriovenous malformation (PAVM).The novel NC TR-MRA sequence utilized consecutive multiple-beam saturation pulses with variable flip angles considering venous blood T1 relaxation to alter the visualized blood signal length. The flowing blood signal length is suppressed according to the number of beam saturation pulses. NC TR-MRA in each flow phase was assessed by subtracting the images with and without beam saturation pulses. In the flow phantom study, three flow velocities were used to simulate physiological pulmonary arterial blood flow. Signal profiles along the flow direction were evaluated in each flow phase. In the volunteer study, five healthy volunteers were recruited, and NC TR-MRA was applied to evaluate relationships between the flow-saturated time and signal enhancement rates. Four regions of interest (ROIs) were determined on the proximal and distal portions of the right basal artery. A patient with PAVM was included to validate whether a PAVM lesion could be visualized using NC TR-MRA. The visualized flow signal lengths extended proportionally with the number of beam saturation pulses in the steady-flow phantom at all velocities. In the volunteer study, NC TR-MRA images showed signal enhancement from the proximal to distal portions of the right basal artery with increase in the flow-saturated time. Signal enhancement rates in all ROIs were significantly positively correlated with the flow-saturated time (p < 0.001 in all ROIs). Further, the lesion and its hemodynamics could be explicitly visualized in the patient with PAVM. Hence, NC TR-MRA using beam saturation pulse can visualize the hemodynamics of the pulmonary artery and may be useful for diagnosing and following patients with PAVM.


Assuntos
Angiografia por Ressonância Magnética , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Artéria Pulmonar/diagnóstico por imagem
5.
Folia Med (Plovdiv) ; 64(2): 202-206, 2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35851770

RESUMO

Pulse oximetry is a technique used to measure the levels of blood oxygen saturation. Because this technique is regarded as non-invasive, easy to apply, and accurate technology, the number of possible applications in general dentistry practice has been gradually increasing. The aim of the present study was to summarise the contemporary research literature concerning the use of pulse oximetry in paediatric dentistry. We made a critical evaluation of the clinical applications of pulse oximetry and the advantages and disadvantages of this technique. Knowledge of innovative methods and techniques for treatment and diagnostics by paediatric dentists is a valuable advantage in dealing with the functional problems in attending dental patients. The expository analysis allows reviewing the succession of this diagnostic approach.


Assuntos
Oximetria , Odontopediatria , Criança , Odontólogos , Humanos , Oxigênio
6.
J Nepal Health Res Counc ; 19(4): 797-804, 2022 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-35615840

RESUMO

BACKGROUND: Tell-Show-Do is most popular and Live modeling is less frequently used behavior management techniques in pediatric dentistry. This study was conducted to compare the children's response to these two techniques by measuring the objective and subjective parameters of anxiety by using pulse rate, oxygen saturation and facial-image scale. METHODS: A cross-sectional study was conducted among 138 children aged 5-10 years from December 2020 - August 2021. Children were randomly divided into three groups: Group A: Live modelling technique (mother as model), Group B: Live modelling technique (father as model), Group C: Tell-Show-Do technique. All were subjected to oral examination and rotary prophylaxis on first dental visit. Pulse oximeter was used to record heart rate, oxygen saturation along with facial-image scale scores before and after the treatment period. RESULTS: The average heart rate at the end of rotary prophylaxis session was significantly lower among children in group A than in group C (p=0.05). facial-image scale scores revealed high significance after the rotary prophylaxis treatment and it was lower in group A than group C and group B (p< 0.001). Average facial-image scale scores of fear perception by girls in group A was lower than group C and group B (p< 0.001). Oxygen saturation showed no significant differences between the three groups. CONCLUSIONS: Live modelling is equally worth practicing as Tell Show Do technique to decrease the anxiety level of children. Anxiety level increased during the procedural work than oral examination and facial image scale indicated anxiety.


Assuntos
Saturação de Oxigênio , Odontopediatria , Criança , Estudos Transversais , Feminino , Frequência Cardíaca , Humanos , Nepal , Odontopediatria/métodos
7.
Int J Mol Sci ; 21(17)2020 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-32899403

RESUMO

High-throughput and large-scale measurements of chlorophyll a fluorescence (ChlF) are of great interest to investigate the photosynthetic performance of plants in the field. Here, we tested the capability to rapidly, precisely, and simultaneously estimate the number of pulse-amplitude-modulation ChlF parameters commonly calculated from both dark- and light-adapted leaves (an operation which usually takes tens of minutes) from the reflectance of hyperspectral data collected on light-adapted leaves of date palm seedlings chronically exposed in a FACE facility to three ozone (O3) concentrations (ambient air, AA; target 1.5 × AA O3, named as moderate O3, MO; target 2 × AA O3, named as elevated O3, EO) for 75 consecutive days. Leaf spectral measurements were paired with reference measurements of ChlF, and predictive spectral models were constructed using partial least squares regression. Most of the ChlF parameters were well predicted by spectroscopic models (average model goodness-of-fit for validation, R2: 0.53-0.82). Furthermore, comparing the full-range spectral profiles (i.e., 400-2400 nm), it was possible to distinguish with high accuracy (81% of success) plants exposed to the different O3 concentrations, especially those exposed to EO from those exposed to MO and AA. This was possible even in the absence of visible foliar injury and using a moderately O3-susceptible species like the date palm. The latter view is confirmed by the few variations of the ChlF parameters, that occurred only under EO. The results of the current study could be applied in several scientific fields, such as precision agriculture and plant phenotyping.


Assuntos
Clorofila A/química , Luz , Ozônio/toxicidade , Phoeniceae/fisiologia , Folhas de Planta/fisiologia , Fluorescência , Phoeniceae/efeitos dos fármacos , Phoeniceae/efeitos da radiação , Fotossíntese , Folhas de Planta/efeitos dos fármacos , Folhas de Planta/efeitos da radiação , Estações do Ano
8.
J Headache Pain ; 18(1): 9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28130626

RESUMO

BACKGROUND: Airplane Headache (AH) occurs during flights and often appears as an intense, short lasting headache during take-off or landing. Reports are limited on pathological mechanisms underlying the occurrence of this headache. Proper diagnosis and treatments would benefit from identification of potential pathways involved in AH pathogenesis. This study aimed at providing a simulated airplane headache condition as a proxy towards identification of its underlying mechanisms. METHODS: Fourteen participants including 7 volunteers suffering from AH and 7 healthy matched controls were recruited after meeting the diagnostic and safety criteria based on an approved study protocol. Simulation of AH was achieved by entering a pressure chamber with similar characteristics of an airplane flight. Selected potential biomarkers including salivary prostaglandin E2 (PGE2), cortisol, facial thermo-images, blood pressure, pulse, and saturation pulse oxygen (SPO) were defined and values were collected before, during and after flight simulation in the pressure chamber. Salivary samples were analyzed with ELISA techniques, while data analysis and statistical tests were handled with SPSS version 22.0. RESULTS: All participants in the AH-group experienced a headache attack similar to AH experience during flight. The non-AH-group did not experience any headaches. Our data showed that the values for PGE2, cortisol and SPO were significantly different in the AH-group in comparison with the non-AH-group during the flight simulation in the pressure chamber. CONCLUSION: The pressure chamber proved useful not only to provoke AH-like attack but also to study potential biomarkers for AH in this study. PGE2, and cortisol levels together with SPO presented dysregulation during the simulated AH-attack in affected individuals compared with healthy controls. Based on these findings we propose to use pressure chamber as a model to induce AH, and thus assess new potential biomarkers for AH in future studies.


Assuntos
Pressão do Ar , Aeronaves , Transtornos da Cefaleia/diagnóstico , Transtornos da Cefaleia/etiologia , Adulto , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
9.
J Magn Reson Imaging ; 45(3): 863-871, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27439061

RESUMO

PURPOSE: To evaluate the dependence of saturation pulse power and duration on glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging and assess the degeneration of human lumbar intervertebral discs (IVDs) using this method. MATERIALS AND METHODS: All images were acquired on a 3T magnetic resonance imaging (MRI) scanner. The CEST effects were measured in the glycosaminoglycan (GAG) phantoms with different concentrations. In the human study, CEST effects were measured in the nucleus pulposus of IVD. We compared the CEST effects among the different saturation pulse powers (0.4, 0.8, and 1.6 µT) or durations (0.5, 1.0, and 2.0 sec) at each Pfirrmann grade (I-V). The relationship between the CEST effects and low back pain was also evaluated. RESULTS: The phantom study showed high correlations between the CEST effects and GAG concentration (R2 = 0.863, P < 0.0001, linear regression). In the human study, the CEST effect obtained with the 0.8 µT power was significantly greater than those obtained with 0.4 (P < 0.01) and 1.6 µT power (P < 0.05) at Pfirrmann grade I. The CEST effect obtained with a 1.0-sec duration was significantly greater than those derived with 0.5 and 2.0 sec (P < 0.01) durations at Pfirrmann grades I and II. The CEST effects in the group with moderate low back pain were significantly lower than those in the groups without pain (P < 0.001) and with mild pain (P = 0.0216). CONCLUSION: The contrast of gagCEST imaging in the lumbar IVDs varied with saturation pulse power and duration. GagCEST imaging may serve as a tool for evaluating IVD degeneration in the lumbar spine. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:863-871.


Assuntos
Glicosaminoglicanos/metabolismo , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/metabolismo , Dor Lombar/diagnóstico por imagem , Dor Lombar/metabolismo , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Degeneração do Disco Intervertebral/complicações , Dor Lombar/etiologia , Masculino , Imagem Molecular/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
JNMA J Nepal Med Assoc ; 56(208): 442-6, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29453477

RESUMO

INTRODUCTION: Nasal packing is one of the most common rhinological procedures in ENT practice exerting local in nose and systemic effects. Systemic effects may be due to poor sleep quality, respiratory difficulty, decreased oxygen saturation, circulatory problems and toxic shock syndrome which can threaten the life of a person.The study was done to investigate the effect on bilateral nasal packing on blood oxygen saturation and blood pressure changes. METHODS: A cross-sectional prospective study was undertaken in Kathmandu Medical College from January 2017 to June 2017. The ethical approval was taken from institutional review committee of KMC and verbal consent was taken from each patient. Thirty patients were included in the study by simple randomized sampling. The association between nasal packing and oxygen saturation and blood pressure was done using ANNOVA and Fisher Exact test. P value of <0.005 was considered statistically significant. SPSS version 20 for windows OS was used for analysis. RESULTS: Blood oxygen saturation on four different days was compared using ANNOVA and paired sample tests. It showed a significant dip on the day of bilateral nasal packing compared to other readings (P value <0.001). Likewise, systolic and diastolic blood pressures showed a significant rise on the day of bilateral nasal packing compared to readings on other days (P value <0.001). CONCLUSIONS: Bilateral nasal packing can lead to significant rise in systolic and diastolic blood pressure and a dip in blood oxygen saturation. Thus care has to be taken while performing bilateral nasal packing in normal patients but much more in high risk patients.


Assuntos
Pressão Sanguínea , Epistaxe/terapia , Obstrução Nasal/sangue , Oximetria , Oxigênio/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos Transversais , Feminino , Fraturas Ósseas , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Osso Nasal/lesões , Obstrução Nasal/fisiopatologia , Procedimentos Cirúrgicos Nasais , Cuidados Pós-Operatórios , Estudos Prospectivos , Adulto Jovem
11.
Radiol Phys Technol ; 9(1): 15-21, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26099607

RESUMO

Amide proton transfer (APT) contrast imaging is based on the chemical exchange saturation transfer (CEST) of protons between the amide groups and bulk water. Here, we demonstrate the effect of the saturation pulse duration on CEST in APT imaging with use of a clinical MR scanner. Four samples were prepared from chicken egg white diluted with H2O. Experiments were performed on a 3T clinical MR scanner with use of a body coil for two-channel parallel radiofrequency transmission. APT images were acquired at six frequency offsets (± 3.0, ± 3.5, ± 4.0 ppm) with respect to the water resonance as well as one far off-resonant frequency (-160 ppm) for signal normalization. The CEST effect was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the CEST effects in the egg white samples with different concentrations at seven saturation pulse durations. The influence of the extension of repetition time (TR) on the CEST effect was also evaluated. The CEST effect was not influenced by the change in TR. The CEST effect was increased significantly with the concentration when the duration was ≥1.0 s (P < 0.01). The CEST effect was highly correlated with the concentration at all saturation pulse durations, and its increase ratio was higher at longer saturation pulse durations. In conclusion, a long saturation pulse duration is useful for the sensitive detection of mobile proteins and peptides in APT imaging.


Assuntos
Amidas/química , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Prótons , Animais
12.
J Magn Reson ; 260: 89-97, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26432398

RESUMO

A selective saturation pulse at fast magic angle spinning (MAS) frequencies (60+kHz) suppresses t1 noise in the indirect dimension of two-dimensional (1)H MAS NMR spectra. The method is applied to a synthetic nucleoside with an intense methyl (1)H signal due to triisopropylsilyl (TIPS) protecting groups. Enhanced performance in terms of suppressing the methyl signal while minimising the loss of signal intensity of nearby resonances of interest relies on reducing spin diffusion--this is quantified by comparing two-dimensional (1)H NOESY-like spin diffusion spectra recorded at 30-70 kHz MAS. For a saturation pulse centred at the methyl resonance, the effect of changing the nutation frequency at different MAS frequencies as well as the effect of changing the pulse duration is investigated. By applying a pulse of duration 30 ms and nutation frequency 725 Hz at 70 kHz MAS, a good compromise of significant suppression of the methyl resonance combined with the signal intensity of resonances greater than 5 ppm away from the methyl resonance being largely unaffected is achieved. The effectiveness of using a selective saturation pulse is demonstrated for both homonuclear (1)H-(1)H double quantum (DQ)/single quantum (SQ) MAS and (14)N-(1)H heteronuclear multiple quantum coherence (HMQC) two-dimensional solid-state NMR experiments.


Assuntos
Ressonância Magnética Nuclear Biomolecular/métodos , Algoritmos , Citidina/análogos & derivados , Citidina/química , DNA/química , Metilação , Compostos de Organossilício/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA