Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 426
Filtrar
1.
Biomed Eng Online ; 23(1): 55, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886737

RESUMO

BACKGROUND: Schizophrenia (SZ), a psychiatric disorder for which there is no precise diagnosis, has had a serious impact on the quality of human life and social activities for many years. Therefore, an advanced approach for accurate treatment is required. NEW METHOD: In this study, we provide a classification approach for SZ patients based on a spatial-temporal residual graph convolutional neural network (STRGCN). The model primarily collects spatial frequency features and temporal frequency features by spatial graph convolution and single-channel temporal convolution, respectively, and blends them both for the classification learning, in contrast to traditional approaches that only evaluate temporal frequency information in EEG and disregard spatial frequency features across brain regions. RESULTS: We conducted extensive experiments on the publicly available dataset Zenodo and our own collected dataset. The classification accuracy of the two datasets on our proposed method reached 96.32% and 85.44%, respectively. In the experiment, the dataset using delta has the best classification performance in the sub-bands. COMPARISON WITH EXISTING METHODS: Other methods mainly rely on deep learning models dominated by convolutional neural networks and long and short time memory networks, lacking exploration of the functional connections between channels. In contrast, the present method can treat the EEG signal as a graph and integrate and analyze the temporal frequency and spatial frequency features in the EEG signal. CONCLUSION: We provide an approach to not only performs better than other classic machine learning and deep learning algorithms on the dataset we used in diagnosing schizophrenia, but also understand the effects of schizophrenia on brain network features.


Assuntos
Eletroencefalografia , Redes Neurais de Computação , Esquizofrenia , Esquizofrenia/diagnóstico , Esquizofrenia/fisiopatologia , Humanos , Eletroencefalografia/métodos , Processamento de Sinais Assistido por Computador , Automação , Diagnóstico por Computador/métodos , Análise Espaço-Temporal
2.
Neural Netw ; 178: 106406, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38838393

RESUMO

Low-light conditions pose significant challenges to vision tasks, such as salient object detection (SOD), due to insufficient photons. Light-insensitive RGB-T SOD models mitigate the above problems to some extent, but they are limited in performance as they only focus on spatial feature fusion while ignoring the frequency discrepancy. To this end, we propose an RGB-T SOD model by mining spatial-frequency cues, called SFMNet, for low-light scenes. Our SFMNet consists of spatial-frequency feature exploration (SFFE) modules and spatial-frequency feature interaction (SFFI) modules. To be specific, the SFFE module aims to separate spatial-frequency features and adaptively extract high and low-frequency features. Moreover, the SFFI module integrates cross-modality and cross-domain information to capture effective feature representations. By deploying both modules in a top-down pathway, our method generates high-quality saliency predictions. Furthermore, we construct the first low-light RGB-T SOD dataset as a benchmark for evaluating performance. Extensive experiments demonstrate that our SFMNet can achieve higher accuracy than the existing models for low-light scenes.

3.
Front Sports Act Living ; 6: 1383411, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38756190

RESUMO

Background: This study compares the reproducibility of freehand (FH) vs. foam cast (FC) scans and investigates the intrarater reliability of the ultrasound FC muscle architecture and tissue organization measurements of the gastrocnemius medialis (GM) and vastus lateralis (VL) muscles with fixed and repositioning FC scans. Methods: Thirteen young adults (22 ± 3 years) underwent repeated sagittal B-mode ultrasound measurements of GM and VL. FH, FC, and repositioned FC scans were conducted. Muscle architecture measurements included muscle thickness (MT), pennation angle (PA), and fascicle length (FL). Spatial frequency analysis assessed muscle tissue organization. Results: MT decreased from 2.1 to 1.8 cm in GM and from 2.4 to 2.2 cm in VL with the FC compared with the FH. Reproducibility between the FH and the FC showed poor to good intraclass correlation coefficients (ICCs) for MT (0.46-0.77) and PA (0.09-0.86) as well as poor to moderate ICCs for FL (0.41), with very low to moderate test-retest variability (TRV) (4%-18%). Tissue organization indicated low to good ICCs (0.21-0.80) with low to moderate TRV (4%-19.5%). The re-scanning results of fixed FC indicated excellent ICCs for MT (0.95-0.996), good for PA (0.77-0.90), and moderate for FL (0.73-0.76), with low TRV (5%-10%) for both muscles. Tissue organization displayed moderate to good ICCs (0.61-0.87) with very low to low TRV (4%-9%). For repositioned FC scans in GM and VL, MT showed good to excellent ICCs (0.86-0.98) with very low to low TRV (2%-8%). PA and FL demonstrated moderate to good ICCs (0.57-0.75), with very low to moderate TRV (2%-13%). Tissue organization revealed ICCs ranging from poor to good (0.13-0.87) for both muscles, with low to moderate TRV (5%-18%). Conclusion: The FC systematically reduced MT by 2-3 mm. Furthermore, reproducibility revealed low ICCs and high data variability for several muscle architecture and tissue organization parameters. Thus, switching methods within a single study is not recommended. Nevertheless, FC ultrasound scans demonstrated excellent intrarater reliability for assessing MT. In the case of fixed FC scans particularly, moderate to excellent ICCs were observed for all muscle architecture and tissue organization parameters, accompanied by very low to low variability. Therefore, FC scans are recommended for investigating acute effects on muscle architecture and tissue organization when the FC remains on the leg throughout the period of measurements.

4.
Perception ; : 3010066241252355, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38752230

RESUMO

Human and artificial features that coexist in certain types of human-like robots create a discrepancy in perceived humanness and evoke uncanny feelings in human observers. However, whether this perceptual mismatch in humanness occurs for all faces, and whether it is related to the uncanny feelings toward them, is unknown. We investigated this by examining perceived humanness for a variety of natural images of robot and human faces with different spatial frequency (SF) information: that is, faces with only low SF, middle SF, and high SF information, and intact (spatially unfiltered) faces. Uncanny feelings elicited by these faces were also measured. The results showed perceptual mismatches that LSF, MSF, and HSF faces were perceived as more human than intact faces. This was particularly true for intact robot faces that looked slightly human, which tended to evoke strong uncanny feelings. Importantly, the mismatch in perceived humanness between the intact and spatially filtered faces was positively correlated with uncanny feelings toward intact faces. Given that the human visual system performs SF analysis when processing faces, the perceptual mismatches observed in this study likely occur in real life for all faces, and as such might be a ubiquitous source of uncanny feelings in real-life situations.

5.
Micromachines (Basel) ; 15(5)2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38793227

RESUMO

Elastic spherical polishing tools effectively conform to the polishing surface and exhibit high efficiency in the removal of materials, so they are extensively used in the sub-aperture polishing stages of optical components. However, their processing is often accompanied by significant mid-spatial frequency (MSF) errors, which critically degrade the performance of optical systems. To suppress the MSF errors generated during polishing with spherical tools, this study investigates the influence factor of MSF errors during the polishing process through an analysis of the convolution effect in material removal. A material removal profile model is established, and a uniform removal simulation is conducted to assess the influence of different shape material removal profiles on MSF errors. Simulation and experimental results show that a Gaussian-like shape material removal profile is more effective in suppressing the MSF errors during polishing compared to the "W" and trapezoidal shape material removal profiles. In addition, based on the characteristics of the RMS decreasing in a serrated trend with the decrease in path spacing, a path spacing optimization method considering the polishing efficiency is proposed to improve the polishing efficiency while controlling the MSF errors, and the effectiveness of the path spacing optimization method is verified by comparing the MSF error at the maximum theoretical path spacing and the path spacing that is less than this. Finally, the path spacing optimization method is used to polish single-crystal silicon to further illustrate its practicality.

6.
Comput Biol Med ; 173: 108293, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38574528

RESUMO

Accurately identifying the Kirsten rat sarcoma virus (KRAS) gene mutation status in colorectal cancer (CRC) patients can assist doctors in deciding whether to use specific targeted drugs for treatment. Although deep learning methods are popular, they are often affected by redundant features from non-lesion areas. Moreover, existing methods commonly extract spatial features from imaging data, which neglect important frequency domain features and may degrade the performance of KRAS gene mutation status identification. To address this deficiency, we propose a segmentation-guided Transformer U-Net (SG-Transunet) model for KRAS gene mutation status identification in CRC. Integrating the strength of convolutional neural networks (CNNs) and Transformers, SG-Transunet offers a unique approach for both lesion segmentation and KRAS mutation status identification. Specifically, for precise lesion localization, we employ an encoder-decoder to obtain segmentation results and guide the KRAS gene mutation status identification task. Subsequently, a frequency domain supplement block is designed to capture frequency domain features, integrating it with high-level spatial features extracted in the encoding path to derive advanced spatial-frequency domain features. Furthermore, we introduce a pre-trained Xception block to mitigate the risk of overfitting associated with small-scale datasets. Following this, an aggregate attention module is devised to consolidate spatial-frequency domain features with global information extracted by the Transformer at shallow and deep levels, thereby enhancing feature discriminability. Finally, we propose a mutual-constrained loss function that simultaneously constrains the segmentation mask acquisition and gene status identification process. Experimental results demonstrate the superior performance of SG-Transunet over state-of-the-art methods in discriminating KRAS gene mutation status.


Assuntos
Neoplasias Colorretais , Proteínas Proto-Oncogênicas p21(ras) , Humanos , Proteínas Proto-Oncogênicas p21(ras)/genética , Sistemas de Liberação de Medicamentos , Mutação/genética , Redes Neurais de Computação , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/genética , Processamento de Imagem Assistida por Computador
7.
Sci Rep ; 14(1): 8980, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637554

RESUMO

Primate visual cortex exhibits key organizational principles: cortical magnification, eccentricity-dependent receptive field size and spatial frequency tuning as well as radial bias. We provide compelling evidence that these principles arise from the interplay of the non-uniform distribution of retinal ganglion cells, and a quasi-uniform convergence rate from the retina to the cortex. We show that convolutional neural networks outfitted with a retinal sampling layer, which resamples images according to retinal ganglion cell density, develop these organizational principles. Surprisingly, our results indicate that radial bias is spatial-frequency dependent and only manifests for high spatial frequencies. For low spatial frequencies, the bias shifts towards orthogonal orientations. These findings introduce a novel hypothesis about the origin of radial bias. Quasi-uniform convergence limits the range of spatial frequencies (in retinal space) that can be resolved, while retinal sampling determines the spatial frequency content throughout the retina.


Assuntos
Córtex Visual , Campos Visuais , Animais , Retina , Células Ganglionares da Retina , Redes Neurais de Computação
8.
J Biomed Opt ; 29(4): 046003, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38650893

RESUMO

Significance: Current methods for wound healing assessment rely on visual inspection, which gives qualitative information. Optical methods allow for quantitative non-invasive measurements of optical properties relevant to wound healing. Aim: Spatial frequency domain imaging (SFDI) measures the absorption and reduced scattering coefficients of tissue. Typically, SFDI assumes homogeneous tissue; however, layered structures are present in skin. We evaluate a multi-frequency approach to process SFDI data that estimates depth-specific scattering over differing penetration depths. Approach: Multi-layer phantoms were manufactured to mimic wound healing scattering contrast in depth. An SFDI device imaged these phantoms and data were processed according to our multi-frequency approach. The depth sensitive data were then compared with a two-layer scattering model based on light fluence. Results: The measured scattering from the phantoms changed with spatial frequency as our two-layer model predicted. The performance of two δ-P1 models solutions for SFDI was consistently better than the standard diffusion approximation. Conclusions: We presented an approach to process SFDI data that returns depth-resolved scattering contrast. This method allows for the implementation of layered optical models that more accurately represent physiologic parameters in thin tissue structures as in wound healing.


Assuntos
Imagens de Fantasmas , Espalhamento de Radiação , Pele , Pele/diagnóstico por imagem , Pele/química , Humanos , Modelos Biológicos , Luz , Cicatrização/fisiologia , Imagem Óptica/métodos , Processamento de Imagem Assistida por Computador/métodos
9.
Comput Biol Med ; 171: 108131, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38447498

RESUMO

Morphological features of individual nuclei serve as a dependable foundation for pathologists in making accurate diagnoses. Existing methods that rely on spatial information for feature extraction have achieved commendable results in nuclei segmentation tasks. However, these approaches are not sufficient to extract edge information of nuclei with small sizes and blurred outlines. Moreover, the lack of attention to the interior of the nuclei leads to significant internal inconsistencies. To address these challenges, we introduce a novel Spatial-Frequency Enhancement Network (SFE-Net) to incorporate spatial-frequency features and promote intra-nuclei consistency for robust nuclei segmentation. Specifically, SFE-Net incorporates a distinctive Spatial-Frequency Feature Extraction module and a Spatial-Guided Feature Enhancement module, which are designed to preserve spatial-frequency information and enhance feature representation respectively, to achieve comprehensive extraction of edge information. Furthermore, we introduce the Label-Guided Distillation method, which utilizes semantic features to guide the segmentation network in strengthening boundary constraints and learning the intra-nuclei consistency of individual nuclei, to improve the robustness of nuclei segmentation. Extensive experiments on three publicly available histopathology image datasets (MoNuSeg, TNBC and CryoNuSeg) demonstrate the superiority of our proposed method, which achieves 79.23%, 81.96% and 73.26% Aggregated Jaccard Index, respectively. The proposed model is available at https://github.com/jinshachen/SFE-Net.


Assuntos
Núcleo Celular , Aprendizagem , Semântica , Processamento de Imagem Assistida por Computador
10.
J Biomed Opt ; 29(3): 036002, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38476220

RESUMO

Significance: The conventional optical properties (OPs) reconstruction in spatial frequency domain (SFD) imaging, like the lookup table (LUT) method, causes OPs aliasing and yields only average OPs without depth resolution. Integrating SFD imaging with time-resolved (TR) measurements enhances space-TR information, enabling improved reconstruction of absorption (µa) and reduced scattering (µs') coefficients at various depths. Aim: To achieve the stratified reconstruction of OPs and the separation between µa and µs', using deep learning workflow based on the temporal and spatial information provided by time-domain SFD imaging technique, while enhancing the reconstruction accuracy. Approach: Two data processing methods are employed for the OPs reconstruction with TR-SFD imaging, one is full TR data, and the other is the featured data extracted from the full TR data (E, continuous-wave component, ⟨t⟩, mean time of flight). We compared their performance using a series of simulation and phantom validations. Results: Compared to the LUT approach, utilizing full TR, E and ⟨t⟩ datasets yield high-resolution OPs reconstruction results. Among the three datasets employed, full TR demonstrates the optimal accuracy. Conclusions: Utilizing the data obtained from SFD and TR measurement techniques allows for achieving high-resolution separation reconstruction of µa and µs' at different depths within 5 mm.


Assuntos
Aprendizado Profundo , Diagnóstico por Imagem , Imagens de Fantasmas , Simulação por Computador
11.
Luminescence ; 39(2): e4670, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38332468

RESUMO

Pan-sharpening is an image fusion approach that combines the spectral information in multispectral (MS) images with the spatial properties of PAN (Panchromatic) images. This vital technique is used in categorization, detection, and other remote sensing applications. In the first step, the article focuses on increasing the finer spatial details in the MS image with PAN images using two levels of fusion without causing spectral deterioration. The suggested fusion method efficiently utilizes image transformation techniques and spatial domain image fusion methods. The luminance component of MS images typically contains spatial features that are not as detailed as the PAN images. A multiscale transform is applied to the intensity/luminance component and PAN image to introduce features into the intensity component. In the first level of processing, coefficients obtained from the non-subsampled contourlet transform are subjected to particle swarm optimization weighted block-based fusion. The second level of fusion is carried out using the concept of spatial frequency to reduce spectral distortion. Numerous reference and non-reference parameters are used to evaluate the sharpened image's quality. In the next step, the article focuses on designing an evaluation metric for analysing spectral distortion based on the Bhattacharyya coefficient and distance. The Bhattacharyya coefficient and distance are calculated for each segmented region to assess the sharpened images' quality. Spectral degradation analysis using proposed techniques can also be useful for analysing materials in the segmented regions. The research findings demonstrate that the spatial features of fused images obtained from the proposed technique increased with the least spectral degradation.

12.
J Biomed Opt ; 29(2): 026002, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38312854

RESUMO

Significance: There is a need for a cost-effective, quantitative imaging tool that can be deployed endoscopically to better detect early stage gastrointestinal cancers. Spatial frequency domain imaging (SFDI) is a low-cost imaging technique that produces near-real time, quantitative maps of absorption and reduced scattering coefficients, but most implementations are bulky and suitable only for use outside the body. Aim: We aim to develop an ultra-miniature SFDI system comprising an optical fiber array (diameter 0.125 mm) and a micro camera (1×1 mm package) to displace conventionally bulky components, in particular, the projector. Approach: First, we fabricated a prototype with an outer diameter of 3 mm, although the individual component dimensions could permit future packaging to a <1.5 mm diameter. We developed a phase-tracking algorithm to rapidly extract images with fringe projections at three equispaced phase shifts to perform SFDI demodulation. Results: To validate the performance, we first demonstrate comparable recovery of quantitative optical properties between our ultra-miniature system and a conventional bench-top SFDI system with an agreement of 15% and 6% for absorption and reduced scattering, respectively. Next, we demonstrate imaging of absorption and reduced scattering of tissue-mimicking phantoms providing enhanced contrast between simulated tissue types (healthy and tumour), done simultaneously at wavelengths of 515 and 660 nm. Using a support vector machine classifier, we estimate that sensitivity and specificity values of >90% are feasible for detecting simulated squamous cell carcinoma. Conclusions: This device shows promise as a cost-effective, quantitative imaging tool to detect variations in optical absorption and scattering as indicators of cancer.


Assuntos
Carcinoma de Células Escamosas , Imagem Óptica , Humanos , Imagem Óptica/métodos , Imagens de Fantasmas , Endoscopia Gastrointestinal
13.
J Biomed Opt ; 29(1): 016006, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38239389

RESUMO

Significance: We present a motion-resistant three-wavelength spatial frequency domain imaging (SFDI) system with ambient light suppression using an 8-tap complementary metal-oxide semiconductor (CMOS) image sensor (CIS) developed at Shizuoka University. The system addresses limitations in conventional SFDI systems, enabling reliable measurements in challenging imaging scenarios that are closer to real-world conditions. Aim: Our study demonstrates a three-wavelength SFDI system based on an 8-tap CIS. We demonstrate and evaluate the system's capability of mitigating motion artifacts and ambient light bias through tissue phantom reflectance experiments and in vivo volar forearm experiments. Approach: We incorporated the Hilbert transform to reduce the required number of projected patterns per wavelength from three to two per spatial frequency. The 8-tap image sensor has eight charge storage diodes per pixel; therefore, simultaneous image acquisition of eight images based on multi-exposure is possible. Taking advantage of this feature, the sensor simultaneously acquires images for planar illumination, sinusoidal pattern projection at three wavelengths, and ambient light. The ambient light bias is eliminated by subtracting the ambient light image from the others. Motion artifacts are suppressed by reducing the exposure and projection time for each pattern while maintaining sufficient signal levels by repeating the exposure. The system is compared to a conventional SFDI system in tissue phantom experiments and then in vivo measurements of human volar forearms. Results: The 8-tap image sensor-based SFDI system achieved an acquisition rate of 9.4 frame sets per second, with three repeated exposures during each accumulation period. The diffuse reflectance maps of three different tissue phantoms using the conventional SFDI system and the 8-tap image sensor-based SFDI system showed good agreement except for high scattering phantoms. For the in vivo volar forearm measurements, our system successfully measured total hemoglobin concentration, tissue oxygen saturation, and reduced scattering coefficient maps of the subject during motion (16.5 cm/s) and under ambient light (28.9 lx), exhibiting fewer motion artifacts compared with the conventional SFDI. Conclusions: We demonstrated the potential for motion-resistant three-wavelength SFDI system with ambient light suppression using an 8-tap CIS.


Assuntos
Diagnóstico por Imagem , Antebraço , Humanos , Diagnóstico por Imagem/métodos , Imagens de Fantasmas , Antebraço/diagnóstico por imagem , Iluminação
14.
J Neurosci ; 44(3)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38050093

RESUMO

Human visual performance for basic visual dimensions (e.g., contrast sensitivity and acuity) peaks at the fovea and decreases with eccentricity. The eccentricity effect is related to the larger visual cortical surface area corresponding to the fovea, but it is unknown if differential feature tuning contributes to this eccentricity effect. Here, we investigated two system-level computations underlying the eccentricity effect: featural representation (tuning) and internal noise. Observers (both sexes) detected a Gabor embedded in filtered white noise which appeared at the fovea or one of four perifoveal locations. We used psychophysical reverse correlation to estimate the weights assigned by the visual system to a range of orientations and spatial frequencies (SFs) in noisy stimuli, which are conventionally interpreted as perceptual sensitivity to the corresponding features. We found higher sensitivity to task-relevant orientations and SFs at the fovea than that at the perifovea, and no difference in selectivity for either orientation or SF. Concurrently, we measured response consistency using a double-pass method, which allowed us to infer the level of internal noise by implementing a noisy observer model. We found lower internal noise at the fovea than that at the perifovea. Finally, individual variability in contrast sensitivity correlated with sensitivity to and selectivity for task-relevant features as well as with internal noise. Moreover, the behavioral eccentricity effect mainly reflects the foveal advantage in orientation sensitivity compared with other computations. These findings suggest that the eccentricity effect stems from a better representation of task-relevant features and lower internal noise at the fovea than that at the perifovea.


Assuntos
Sensibilidades de Contraste , Córtex Visual , Masculino , Feminino , Humanos , Orientação/fisiologia , Córtex Visual/fisiologia , Fóvea Central/fisiologia , Ruído
15.
Atten Percept Psychophys ; 86(1): 248-262, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37872436

RESUMO

When observing a simple visual scene such as an array of dots, observers can easily and automatically extract their number. How does our visual system accomplish this? We investigate the role of specific spatial frequencies to the encoding of number through cross-adaptation. In two experiments, observers were peripherally adapted to six randomly generated sinusoidal gratings varying from relatively low-spatial frequency (M = 0.44 c/deg) to relatively high-spatial frequency (M = 5.88 c/deg). Subsequently, observers judged which side of the screen had a higher number of dots. We found a strong number-adaptation effect to low-spatial frequency gratings (i.e., participants significantly underestimated the number of dots on the adapted side) but a significantly reduced adaptation effect for high-spatial frequency gratings. Various control conditions demonstrate that these effects are not due to a generic response bias for the adapted side, nor moderated by dot size or spacing effects. In a third experiment, we observed no cross-adaptation for centrally presented gratings. Our results show that observers' peripheral number perception can be adapted even with stimuli lacking any numeric or segmented object information and that low spatial frequencies adapt peripheral number perception more than high ones. Together, our results are consistent with recent number perception models that suggest a key role for spatial frequency in the extraction of number from the visual signal (e.g., Paul, Ackooij, Ten Cate, & Harvey, 2022), but additionally suggest that some spatial frequencies - especially in the low range and in the periphery - may be weighted more by the visual system when estimating number. We argue that the cross-adaptation paradigm is also a useful methodology for discovering the primitives of visual number encoding.

16.
Brain Sci ; 13(12)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137147

RESUMO

Recognizing the emotions of faces in a crowd is crucial for understanding overall behavior and intention as well as for smooth and friendly social interactions. However, it is unclear whether the spatial frequency of faces affects the discrimination of crowd emotion. Although high- and low-spatial-frequency information for individual faces is processed by distinct neural channels, there is a lack of evidence on how this applies to crowd faces. Here, we used functional magnetic resonance imaging (fMRI) to investigate neural representations of crowd faces at different spatial frequencies. Thirty-three participants were asked to compare whether a test face was happy or more fearful than a crowd face that varied in high, low, and broad spatial frequencies. Our findings revealed that fearful faces with low spatial frequencies were easier to recognize in terms of accuracy (78.9%) and response time (927 ms). Brain regions, such as the fusiform gyrus, located in the ventral visual stream, were preferentially activated in high spatial frequency crowds, which, however, were the most difficult to recognize behaviorally (68.9%). Finally, the right inferior frontal gyrus was found to be better activated in the broad spatial frequency crowds. Our study suggests that people are more sensitive to fearful crowd faces with low spatial frequency and that high spatial frequency does not promote crowd face recognition.

17.
Front Psychol ; 14: 1247687, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125858

RESUMO

Introduction: Visual perception is a complex process that involves the analysis of different spatial and temporal features of the visual environment. One critical aspect of this process is adaptation, which allows the visual system to adjust its sensitivity to specific features based on the context of the environment. Numerous theories highlight the significance of the visual scene and its spectral properties in perceptual and adaptation mechanisms. For example, size perception is known to be influenced by the spatial frequency content of the visual scene. Nonetheless, several inquiries still exist, including how specific spectral properties of the scene play a role in size perception and adaptation mechanisms. Methods: In this study, we explore aftereffects on size perception following adaptation to a natural scene with a biased spectral amplitude distribution. Twenty participants had to manually estimate the horizontal size of a projected rectangle after adaptation to three visually biased conditions: vertical-biased, non-biased, and horizontal-biased. Size adaptation aftereffects were quantified by comparing the perceptual responses from the non-biased condition with the vertical- and horizontal-biased conditions. Results: We found size perception shifts which were contingent upon the specific orientation and spatial frequency distribution inherent in the amplitude spectra of the adaptation stimuli. Particularly, adaptation to vertical-biased produced a horizontal enlargement, while adaptation to horizontal-biased generated a decrease in the horizontal size perception of the rectangle. On average, size perception was modulated by 5-6%. Discussion: These findings provide supporting evidence for the hypothesis that the neural mechanisms responsible for processing spatial frequency channels are involved in the encoding and perception of size information. The implications for neural mechanisms underlying spatial frequency and size information encoding are discussed.

19.
J Biomed Opt ; 28(12): 126003, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38098981

RESUMO

Significance: Postoperative surgical wound infection is a serious problem around the globe, including in countries with advanced healthcare systems, and a method for early detection of infection is urgently required. Aim: We explore spatial frequency domain imaging (SFDI) for distinguishing changes in surgical wound healing based on the tissue scattering properties and surgical wound width measurements. Approach: A comprehensive numerical method is developed by applying a three-dimensional Monte Carlo simulation to a vertical heterogeneous wound model. The Monte Carlo simulation results are validated using resin phantom imaging experiments. Results: We report on the SFDI lateral resolution with varying reduced scattering value and wound width and discuss the partial volume effect at the sharp vertical boundaries present in a surgical incision. The detection sensitivity of this method is dependent on spatial frequency, wound reduced scattering coefficient, and wound width. Conclusions: We provide guidelines for future SFDI instrument design and explanation for the expected error in SFDI measurements.


Assuntos
Ferida Cirúrgica , Humanos , Método de Monte Carlo , Diagnóstico por Imagem , Simulação por Computador , Imagens de Fantasmas
20.
Front Comput Neurosci ; 17: 1241455, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37941764

RESUMO

The Contrast Sensitivity Function (CSF) is the measure of an observer's contrast sensitivity as a function of spatial frequency. It is a sensitive measure to assess visual function in fundamental and clinical settings. Human contrast sensitivity is subserved by different spatial frequency channels. Also, it is known that amblyopes have deficits in contrast sensitivity, particularly at high spatial frequencies. Therefore, the aim of this study was to assess whether the contrast sensitivity function is subtended by the same spatial frequency channels in control and amblyopic populations. To determine these spatial frequency channels, we performed an exploratory factor analysis on five datasets of contrasts sensitivity functions of amblyopic and control participants measured using either gratings or noise patches, taken from our previous studies. In the range of 0.25-10 c/d, we identified two spatial frequency channels. When the CSF was measured with noise patches, the spatial frequency channels presented very similar tuning in the amblyopic eye and the fellow eye and were also similar to what was observed in controls. The only major difference was that the weight attributed to the high frequency channel was reduced by approximately 50% in the amblyopic eye. However, when the CSF was measured using gratings, the spatial frequency channels of the amblyopic eye were tuned toward lower spatial frequencies. These findings suggest that there is no mechanistic deficit for contrast sensitivity in amblyopia and that amblyopic vision may just be subjected to excessive internal noise and attenuation at higher spatial frequencies, thereby supporting the use of therapeutic strategies that involve rebalancing contrast.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...