Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Surg Case Rep ; 10(1): 172, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39017809

RESUMO

BACKGROUND: Post-pneumonectomy syndrome (PPS) is a rare but serious condition that can occur after pneumonectomy. It is characterized by a mediastinal shift towards the vacated hemithorax, which can potentially lead to respiratory failure. The management of PPS poses a clinical challenge, especially in the context of the limited availability of certain therapeutic devices due to regulatory restrictions in Japan. CASE PRESENTATION: A 36-year-old female with stage IB non-small cell lung cancer underwent left pneumonectomy. Approximately 2 years later, she developed dyspnea. After consulting with our hospital, subsequent imaging revealed an extreme mediastinal shift causing bronchial obstruction. Emergency thoracotomy and subsequent sulfur hexafluoride (SF6) injections were successfully used to manage her condition. Over the course of follow-up, the interval between SF6 injections was extended from 3 to 11 months, indicating an improvement in the intrathoracic condition. CONCLUSIONS: This case illustrates the efficacy of SF6 gas in treating PPS and in reducing the frequency of medical interventions. SF6 gas administration is safe and effective for the treatment of patients with PPS.

2.
Ann Work Expo Health ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985848

RESUMO

In Europe, respiratory protective devices must be certified before they can be marketed. Among the parameters of interest, inward leakage (IL) characterizes the tightness between the face seal and the face, to verify that the device is well-designed. European standard EN 13274-1 (2001) and International Organization for Standardization (ISO) standard ISO 16900-1 (2019) specify that IL should be measured using sodium chloride (NaCl) aerosol or sulfur hexafluoride (SF6) gas. For reusable masks made of nonporous materials, both test agents are considered equally acceptable. However, the few studies that have compared IL values measured with various aerosols and gases have come to divergent conclusions. This work then aimed to measure IL with the test agents recommended by the standards to determine whether they are really equivalent. Since krypton (Kr) is an interesting candidate for replacing SF6 in standard tests, IL was assessed with SF6 and Kr simultaneously, and with NaCl aerosol using various calculation methods. Tests were carried out on 5 models of full-face masks donned on a headform connected to a breathing machine simulating 3 sinusoidal breathing rates of various intensities. The respirator fit on the headform was evaluated using a controlled negative pressure method to determine a manikin fit factor. Four scenarios were then tested to represent very poor, bad, good, and excellent fit. Gas concentration was measured using a mass spectrometer, and IL was calculated for SF6 and Kr. A combination of 3 devices allowed the determination of the number-based concentration of particles with diameters between 20 nm and 2 µm, and IL was calculated for each of the 33 channels, as well as using a cumulative number concentration. In addition, to comply with standards, a conversion was carried out to calculate IL using a cumulative mass concentration. The results of this work evidenced that the IL values measured with NaCl were systematically lower than those determined with gases. IL was also shown to vary with particle size, with a maximum value exceeding that calculated with cumulative concentrations (in number or mass). As part of the revision of the standards, protocols for measuring inward leakage should be redefined. On the one hand, acceptability thresholds should be re-evaluated according to the nature of the test agent (gas or aerosol), as it is clear that the 2 options do not give the same results for a given configuration. On the other hand, the aerosol leakage measurement protocol needs to be reworked to enable the measurement of a well-defined, robust, and reproducible inward leakage value.

3.
Chemistry ; : e202402028, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38958451

RESUMO

Sulfur based deoxyfluorination reagents are usually derived from the corrosive gas SF4. Herein, we report the synthesis and properties of an easily accessible phosphonium salt [(tmg)3PF]+SF5- (1) which was obtained from the reaction of sulfur hexafluoride (SF6) with tris(tetramethylguanidinyl)phosphine. The performance of this crystalline SF5- salt as a reagent in deoxyfluorination reactions was investigated together with a second SF5- salt [(R1)3PF]+SF5- (2) containing bulky substituents (R1 = 1,3-di-tert-butylimidazolidin-2-ylidenamino). Both reagents proved to be effective for the deoxyfluorination of various functional groups including alcohols, anhydrides, and amides.

4.
Diagnostics (Basel) ; 14(14)2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39061620

RESUMO

BACKGROUND: The present study compares the anatomical and functional outcomes (best-corrected visual acuity (BCVA) and central macular thickness (CMT)) among membrane peeling with or without SF6 tamponade in patients with epiretinal membrane. METHODS: We retrospectively reviewed patients diagnosed with macular pucker who underwent pars plana vitrectomy and membrane peeling in a tertiary center in Taiwan from January 2021 to December 2022. Subjects were categorized into with or without SF6 tamponade groups (SF6 group and BSS group). Postoperative intraocular pressure and complications were documented. Logistic regression analyses were performed to identify the prognostic factors during follow-up. RESULTS: A total of 89 eyes were enrolled, including 34 eyes in the BSS group and 55 eyes in the SF6 group. The mean age was 66 years old, and a female predilection was demonstrated. Both groups possessed statistically significant improvement in BCVA and CMT after the operation. There was no significant difference in CMT between the groups at any time of observation, yet we observed significant differences in baseline BCVA and BCVA at last follow-up among the two groups. Both groups yielded an approximate enhancement of LogMAR 0.3 in BCVA postoperatively. There was no significant difference noted in postoperative IOP between the two groups. CONCLUSION: Membrane peeling with or without SF6 tamponade yields comparable outcomes anatomically and functionally. This may indicate that SF6 tamponade for idiopathic macular pucker surgery may not provide extra benefit, and therefore warrants reconsideration as standard procedure.

5.
Molecules ; 29(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38398539

RESUMO

Sulfur hexafluoride (SF6), which survives in the atmosphere for an extremely long period of time, is the most potent greenhouse gas regulated under the Kyoto Protocol. So, the accurate monitoring of atmospheric SF6 plays an important role in the study of the control policies for reducing greenhouse gas emissions. The instruments for SF6 measurement are typically calibrated using certified reference materials. The concentrations of the commercially available SF6 reference materials usually have a broad range, from 1 µmol/mol to 6000 µmol/mol. Some characteristics including sensitivity, linear range, relative standard deviation, and accuracy are crucial for the determination of SF6 in such a broad concentration range. Therefore, the selection of a proper detector for the accurate determination of SF6 with such a broad range is extremely important to establish a gas chromatography (GC) method for developing SF6 reference materials. In this paper, several typical GC methods with different detectors, including a thermal conductivity detector (TCD), a pulsed discharge helium ionization detector (PDHID), and a flame photometric detector (FPD), were carefully established for the accurate determination of SF6 with different concentrations. The results show that an FPD detector has a relatively narrow linearity range, thus a quadratic equation should be established for building a calibration curve. The PDHID and TCD have good linearity with coefficients of 1.0000 in the concentration range of 10-100 µmol/mol (using a PDHID), and 100-1000 µmol/mol (using a TCD), respectively. Further considering the measurement errors of indication results, the PDHID is suitable for SF6 measurement when the concentrations are below 100 µmol/mol, whereas the TCD is suitable for SF6 measurement when the concentrations are over 100 µmol/mol. These results provide useful guidance in choosing an appropriate GC detector for the accurate determination of SF6, which are especially very helpful for developing SF6 reference materials.

6.
Insights Imaging ; 15(1): 65, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38411872

RESUMO

OBJECTIVES: To investigate the rate of adverse events (AEs) caused by intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications retrospectively and to explore practical measures for prevention and treatment of them. MATERIALS AND METHODS: This study enrolled 83,778 contrast-enhanced ultrasound (CEUS) examinations using sulfur hexafluoride microbubbles intravenously performed during 11 years. Age, gender, and target organs of all CEUS patients were recorded. For cases of AEs, their medical history and laboratory results were also collected. The process of AEs was assessed and categorized. Besides, the management of AEs were recorded. RESULTS: Twenty patients had sulfur hexafluoride microbubbles-related AEs. The AE rate was 0.024%. No significant difference was observed between patients with AEs and the whole group for age and sex distribution. All AEs happened in liver examinations. Among them, 7 (35%) were mild, 8 (40%) were moderate, and 5 (25%) were severe. They were categorized into 15 allergic-like reactions and 5 physiologic reactions. The manifestations of mild and moderate AEs mainly include urticaria, chills, and mild hypoxia, which could be eased by simple management. Severe cases had anaphylactic shock, generalized convulsions, and diffuse erythema with hypotension respectively. They need close monitoring and oxygen inhalation with anti-shock and anti-anaphylactic treatment. Most cases started within 30 min and recovered within 1 day. CONCLUSIONS: Intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications was safe with rare AEs. AEs were more likely to happen in abdominal applications than superficial ones. A well-designed emergency plan should be available for clinical use of sulfur hexafluoride microbubbles to reduce AEs and to deal with AEs properly. CRITICAL RELEVANCE STATEMENT: Intravenous administration of sulfur hexafluoride microbubbles in abdominal and superficial applications reported few AEs and could be considered safe but severe AEs are life-threatening. We analyzed the influence factors of AEs and propose some methods for prevention and treatment of them, which can further improve the safety of sulfur hexafluoride microbubbles in clinical practice. KEY POINTS: • The AE rate of sulfur hexafluoride microbubbles in abdominal and superficial applications was 0.024%. • Patients were more likely to have AEs in abdominal applications than superficial ones. • Severe AEs are life-threatening and need prompt identification and treatment. • We summarized some detailed suggestions for clinical prevention and treatment of AEs.

7.
Int J Retina Vitreous ; 10(1): 16, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317211

RESUMO

BACKGROUND: In vitrectomy for rhegmatogenous retinal detachment, long-acting gas tamponades (LGT) such as C3F8 or C2F6 may improve surgical success rate due to their prolonged effect compared to a short-acting gas tamponade (SGT) with SF6. On the other hand, SGT allow a significantly faster visual rehabilitation after surgery and may reduce the risk of gas-related complications. As comparative data in retinal detachment surgery is limited, we assessed the outcomes of vitrectomies using either LGT or SGT. METHODS: We retrospectively analyzed 533 eyes of 524 consecutive patients diagnosed with primary rhegmatogenous retinal detachment not complicated by proliferative vitreoretinopathy (PVR) and treated by vitrectomy at two clinical sites. Depending on the site the patients presented at, they received either preferentially LGT (study site 1) or SGT (study site 2). Retinal re-detachment rates during a period of 6 months following surgery were analyzed. RESULTS: At study site 1, 254 of 278 eyes (91.4%) were treated by LGT (C3F8 72.3%; C2F6 19.1%), whereas at study site 2, 246 of 255 eyes (96.5%) received SGT (SF6). Rates of retinal re-detachment in the LGT- and SGT-treated groups were similar with 23 of 254 eyes (9.1%) and 24 of 246 eyes (9.8%), respectively (p = 0.9). Median time to re-detachment was 5.7 weeks in the LGT-treated group and 4.4 weeks in the SGT-treated group (p = 0.4). CONCLUSION: In rhegmatogenous retinal detachment repair by vitrectomy, the use of SGT results in comparable rates of successful retinal re-attachment as LGT. Given the faster visual rehabilitation with SGT, these results suggest SGT as a sensible alternative to LGT in surgery of retinal detachment without PVR.

8.
J Pharm Pract ; 37(2): 509-512, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36803045

RESUMO

Ultrasound enhancing agents (UEAs) are medications that enable clear visualization of ultrasound images. While large studies have demonstrated the safety of these agents, case reports of life-threatening reactions temporally associated with their use have been published and reported to the Food and Drug Administration. Current literature describes the most serious adverse reactions due to UEAs to be allergic in nature; however, embolic phenomena may play a role as well. Here, we report a case of unexplained cardiac arrest following the administration of sulfur hexafluoride (Lumason®) in an adult inpatient undergoing echocardiography where resuscitative efforts were ultimately unsuccessful, and review possible mechanisms of cardiac arrest based on prior published literature.


Assuntos
Parada Cardíaca , Hexafluoreto de Enxofre , Adulto , Humanos , Hexafluoreto de Enxofre/efeitos adversos , Meios de Contraste/efeitos adversos , Ultrassonografia/métodos , Administração Intravenosa , Parada Cardíaca/induzido quimicamente
9.
J Fr Ophtalmol ; 47(2): 103979, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37858497

RESUMO

PURPOSE: To compare the efficacy of three different gases for intraocular tamponade: 100% air, 10% perfluoropropane (C3F8), and 10% sulfur hexafluoride (SF6), in Descemet's membrane endothelial keratoplasty (DMEK). MATERIALS AND METHODS: The medical records of 138 patients who underwent DMEK were reviewed retrospectively, with the primary outcome being the rebubbling rate in the first week following surgery. Other clinical outcomes, such as best-corrected visual acuity (BCVA), central corneal thickness (CCT), incidence of rebubbling after the first week, endothelial cell density (ECD), graft detachment, graft failure, pupillary block, and intraocular pressure (IOP) changes were also analyzed. RESULTS: Of the 138 patients, 57 were in group 1 (treated with air), 44 in group 2 (treated with 10% C3F8), and 37 in group 3 (treated with 10% SF6). Group 3 showed significantly lower rates of graft detachment and rebubbling compared to groups 1 and 2 (P<0.001). However, there was no significant difference in postoperative BCVA among the groups. At one year, the mean endothelial cell loss was 32% in group 1, 30% in group 2, and 33% in group 3 (P=0.715). One patient in group 1 experienced pupillary block and increased IOP, while there were no such occurrences in the other groups. There was no difference between the groups in terms of graft failure. CONCLUSION: The use of 10% SF6 in DMEK surgery may be a good option due to its efficacy in preventing graft detachment, low rebubbling rate, and potential for minimizing complications.


Assuntos
Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Humanos , Lâmina Limitante Posterior/cirurgia , Gases , Estudos Retrospectivos , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/efeitos adversos , Acuidade Visual , Tamponamento Interno , Câmara Anterior/cirurgia , Distrofia Endotelial de Fuchs/cirurgia , Hexafluoreto de Enxofre , Endotélio Corneano/transplante
10.
Chest ; 165(2): 396-404, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37716474

RESUMO

BACKGROUND: The early life origins of chronic pulmonary diseases are thought to arise in peripheral small airways. Predictors of ventilation inhomogeneity, a proxy of peripheral airway function, are understudied in schoolchildren. RESEARCH QUESTION: Is the double-tracer gas single-breath washout (DTG-SBW) measurement feasible in a pediatric field study setting? What are the predictors of the DTG-SBW-derived ventilation inhomogeneity estimate in unselected schoolchildren? STUDY DESIGN AND METHODS: In this prospective cross-sectional field study, a mobile lung function testing unit visited participating schools in Switzerland. We applied DTG-SBW, fraction of exhaled nitric oxide (Feno), and spirometry measurements. The DTG-SBW is based on tidal inhalation of helium and sulfur-hexafluoride, and the phase III slope (SIIIHe-SF6) is derived. We assessed feasibility, repeatability, and associations of SIIIHe-SF6 with the potential predictors of anthropometrics, presence of wheeze (ie, parental report of one or more episode of wheeze in the prior year), Feno, FEV1, and FEV1/FVC. RESULTS: In 1,782 children, 5,223 DTG-SBW trials were obtained. The DTG-SBW was acceptable in 1,449 children (81.3%); the coefficient of variation was 39.8%. SIIIHe-SF6 was independently but weakly positively associated with age and BMI. In 276 children (21.2%), wheeze was reported. SIIIHe-SF6 was higher by 0.049 g.mol.L-1 in children with wheeze compared with those without and remained associated with wheeze after adjusting for age and BMI in a multivariable linear regression model. SIIIHe-SF6 was not associated with Feno, FEV1, and FEV1/FVC. INTERPRETATION: The DTG-SBW is feasible in a pediatric field study setting. On the population level, age, body composition, and wheeze are independent predictors of peripheral airway function in unselected schoolchildren. The variation of the DTG-SBW possibly constrains its current applicability on the individual level. TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT03659838; URL: www. CLINICALTRIALS: gov.


Assuntos
Gases , Respiração , Humanos , Criança , Estudos Prospectivos , Estudos Transversais , Testes Respiratórios , Hexafluoreto de Enxofre
11.
Ann Work Expo Health ; 68(1): 86-96, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-38037180

RESUMO

Sulfur hexafluoride (SF6) is the reference tracer gas in many international standards for characterizing respiratory protective devices (RPD), fume cupboards, building ventilations, and other installations. However, due to its significant impact on global warming, its use is becoming increasingly restrictive. Krypton 84 (Kr) was chosen to be a possible replacement based on theoretical and practical criteria for the properties that a substitute gas should possess. While compliance with these criteria is generally sufficient to guarantee the reliability of the choice, it is essential in the case of widespread use such as a standard to validate experimentally that this tracer has the same behavior as SF6. In this regard, numerous tests have been carried out to characterize the face leakage of RPD and the rupture of containment of fume cupboards performance tests under different operating conditions. The results obtained are identical with both tracers and lead us to propose the use of Kr as a new reference gas in standards for which SF6 was used.


Assuntos
Exposição Ocupacional , Humanos , Exposição Ocupacional/prevenção & controle , Criptônio , Reprodutibilidade dos Testes , Gases/análise , Hexafluoreto de Enxofre/análise , Padrões de Referência
12.
Appl Radiat Isot ; 205: 111155, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38159451

RESUMO

Sulfur hexafluoride gas (SF6) is used as a dielectric insulator in the acceleration process of certain medical linear accelerator waveguides. Nevertheless, some innovative development and investigation cases require intervention in the linear accelerator or, specifically, on the waveguide, which could affect the sealing of the device. In this regard, vacuum sealing systems can be compromised, affecting the properties of the radiation beams produced. The presence of sulfur hexafluoride or air inside the VARIAN 6/100 waveguide was investigated under different pressure conditions and non-uniform electric fields, adapting Monte Carlo simulation techniques for modeling radiation transport coupled with electric fields. Obtained results indicated the suitability of the proposed approach, while comparisons with theoretical approaches and experimental evidence supported the model's consistency.

13.
Arq. bras. oftalmol ; 87(2): e2022, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1533804

RESUMO

ABSTRACT Purpose: To compare the injection of small amounts of undiluted C3F8 with the traditional gas injection in vitrectomy for macular hole treatment. Methods: This clinical trial included 26 individuals divided into two groups. Group 1 received an intravitreal injection of 0.9-1.0 mL of 100% C3F8, and Group 2 received 15-20 mL of 20% C3F8. Results: The median intraocular gas duration was 31 days in Group 1 and 34 in Group 2. The median letter gains in corrected distance visual acuity for the 26th postoperative week were 20 letters in Group 1 and 12.5 in Group 2. The median intraocular pressure was normal in both groups. Primary anatomical success was 11/13 in both groups. Conclusions: The use of C3F8 gas in a small undiluted volume is an alternative that slightly reduces the duration of the gas without negatively affecting the anatomical and visual response.

14.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027169

RESUMO

Objective:To investigate the myocardial protective effect of extracorporeal cardiac shock wave therapy (CSWT) combined with sulfur hexafluoride microbubble post-conditioning on myocardial ischemia-reperfusion injury (MI/RI) in rats, and to provide theoretical support for clinical treatment of MI/RI.Methods:A total of 32 male SD rats were randomly divided into 4 groups: sham operation group (Sham group), MI/RI group (IR group), CSWT group (IR+ SW group), and CSWT combined with sulfur hexafluoride microbubble treatment group (IR+ SW+ MB group), with 8 rats in each group. Therapeutic intervention was performed in IR+ SW group and IR+ SW+ MB group on the 1st, 3rd and 5th day after modeling. The left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular ejection fraction (LVEF) and left ventricular fractional shortening (LVFS) of the rats were measured by echocardiography before and after treatment. On the 7th day, myocardial fibrosis was assessed by Masson staining, and cardiomyocyte apoptosis was observed by TUNEL staining. The myocardial apoptotic proteins Bcl-2, BAX, Cleaved-Caspase-3 and Cleaved-Caspase-9 in the infarct boundary area were detected by Western blot. The differences of the above indexes among different groups were compared.Results:①There was no significant change in heart rhythm and heart rate among the groups before and after treatment, and there was no significant difference in heart rate ( P>0.05). ②The echocardiographic results after treatment showed that, compared with IR group, LVEDD and LVESD in IR+ SW group and IR+ SW+ MB group decreased in turn, while LVEF and LVFS increased in turn with significant differences between each two groups (all P<0.05). ③Compared with IR group, the degrees of myocardial fibrosis and apoptosis in IR+ SW group and IR+ SW+ MB group were alleviated in turn, and the relief in IR+ SW+ MB group was the most obvious. Quantitative analysis showed that compared with IR group, the proportions of cardiomyocyte apoptosis in IR+ SW group and IR+ SW+ MB group decreased in turn, and there were significant differences between each two groups (all P<0.05). ④The results of Western blot detection showed that compared with IR group, the levels of Bcl-2 in IR+ SW group and IR+ SW+ MB group increased in turn, while the levels of BAX and the activation level of Caspase-3 and Caspase-9 protein decreased in turn. These differences were all statistically significant between each two groups (all P<0.05) except for the activation level of Caspase-3 protein between IR+ SW group and IR+ SW+ MB group ( P>0.05). Conclusions:CSWT combined with sulfur hexafluoride microbubble therapy can improve left ventricular remodeling and left ventricular systolic function by inhibiting cardiomyocyte apoptosis.

15.
Ther Adv Ophthalmol ; 15: 25158414231208279, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37915881

RESUMO

Background: In young adults with rhegmatogenous retinal detachment, pneumatic retinopexy can be a cost-effective and minimally invasive highly effective method in suitable cases. Objectives: To evaluate the role of pneumatic retinopexy in the treatment of young adults with rhegmatogenous retinal detachment (RRD) and the factors that may affect the success of pneumatic retinopexy. Design: Retrospective study. Methods: The study included 67 eyes of 67 patients aged between 21 and 40 who underwent pneumatic retinopexy (PR) between January 2015 and June 2021 for primary RRD. We retrospectively analyzed the prognostic factors that may affect the success of PR, such as preoperative age, best corrected visual acuity, tear site, lens condition, and axial length. Results: PR was successful in 61.2% of the patients, whereas 38.8% required secondary surgery. Between the group that had a single surgery (Group 1) and the group that required secondary surgery (Group 2) the tear location, axial length, and volumes of gases used were statistically different (p = 0.04, p < 0.001, and p = 0.02, respectively). There was a significant difference in visual acuity before and after surgery in the group that was successful with a single surgery (Friedman χ2 = 40.051, p < 0.001). There was no significant difference between the two groups in terms of intraocular pressure (p > 0.05), and glaucoma was not observed in the postoperative period. Conclusion: Since it is a minimally invasive and cost-effective method that provides rapid visual rehabilitation, it can be considered as first-line therapy in young adults who are suitable for PR.

16.
Environ Pollut ; 335: 122266, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37499965

RESUMO

Sulfur hexafluoride (SF6) is a powerful greenhouse gas with a high global warming potential. While SF6 emissions from urban areas have been extensively studied, our knowledge about SF6 concentrations in the oceanic atmosphere and its air-sea exchange remains limited. Herein, the concentrations of SF6 in the atmosphere and surface seawater of the WPO (Western Pacific Ocean) and EIO (Eastern Indian Ocean) were comprehensively characterized from 2019 to 2022 in the first long-term study. The mean mixing ratios of SF6 over the WPO and EIO during 2019-2020 (2021-2022) were 10.9 (11.2) and 10.9 (11.1) ppt, respectively. The atmospheric SF6 concentration over the WPO and EIO increased at rates of 0.40 ± 0.06 and 0.58 ± 0.28 ppt yr-1, respectively, surpassing previously reported annual growth rates. The faster growth was primarily attributed to the influence of polluted air masses originating from eastern Asian countries, particularly Japan, Northeast China, and India. This might explain why the radiative forcing caused by SF6 in the study region was higher than the global average. The concentrations of SF6 in the surface seawater of the WPO and EIO ranged from 0.33 to 2.54 fmol kg-1, and the distribution was affected by atmospheric concentrations and ocean currents. Estimated air-sea fluxes revealed that the ocean acted as a significant sink of atmospheric SF6, and the preliminary estimation suggested oceanic uptake accounts for about 7% of annual global SF6 emissions. Based on these findings, we tentatively suggest that the strength of the ocean as a sink of SF6 may warrant reassessment. The global oceanic uptake of SF6 has the potential to reduce its global abundance and environmental impacts.


Assuntos
Monitoramento Ambiental , Hexafluoreto de Enxofre , Hexafluoreto de Enxofre/análise , Oceano Índico , Água do Mar , Oceano Pacífico , Atmosfera
17.
Cureus ; 15(5): e38969, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37313090

RESUMO

PURPOSE: To investigate changes in vision-related quality of life in patients treated with pars plana vitrectomy (PPV) for rhegmatogenous retinal detachment (RRD) and compare groups according to the type of gas tamponade used. METHODS: Participants in this study were 48 patients with RRD who were treated with PPV and gas tamponade (sulfur hexafluoride (SF6) or perfluoropropane (C3F8)) without internal limiting membrane peeling. All participants underwent slit-lamp examination, fundoscopy, axial-length measurement, and completed the Vision Function Questionnaire-25 (VFQ-25) at month six postoperatively. We compared VFQ-25 composite and subscale scores in the SF6 and C3F8 groups and investigated any correlations between age, best corrected visual acuity (BCVA), axial length, and VFQ-25 scores. RESULTS: The demographic and clinical characteristics of the two groups (axial length, macular status, retinal detachment extent, duration of symptoms, and lens status) were comparable between the two groups. We found a statistically significant decrease in general vision (GV), ocular pain (OP), and driving (D) scores in the C3F8 group compared to the SF6 group. The VFQ-25 composite score was comparable in the two groups. Similarly, all other subscales of the VFQ-25 did not differ significantly between the two groups. Age and BCVA did not significantly correlate with VFQ-25 composite and subscale scores. CONCLUSION: Specific VFQ-25 subscales were decreased in patients with RRD treated with C3F8 as a gas tamponade compared to SF6. This finding warrants further research in the tamponade agents used in PPV surgeries.

18.
Heliyon ; 9(4): e15388, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37123910

RESUMO

The goal of present study is to explore how the size and functionalization of graphene quantum dots (GQDs) affect their sensing capabilities. Specifically, we investigated the adsorption of SO2, SOF2, SO2F2, and SF6 on GQDs that were functionalized with -CH3, -COCH3, and -NH2. We used density functional theory to analyse the electronic properties of these functionalized GQDs and found that the functionalization significantly altered their electronic properties. For example, the B3LYP H-L gap of pristine triangulene was 3.9eV, while the H-L gap of functionalized triangulene ranged from 2.8 eV to 3.6 eV (using the B3LYP functional). Our results indicate that -NH2 functionalized phenalenyl and triangulene provide strong interaction with SO2, with adsorption energies of -0.429 eV and -0.427 eV, respectively. These adsorption properties exhibit physisorption, leading to high gas sensitivity and superior recovery time. The findings of this study provide new insights into the potential use of GQDs for detecting the decomposed constituents of sulfur hexafluoride, which can be beneficial for assessing the operation status of SF6 insulated devices. Overall, our calculations suggest that functionalized GQDs can be employed in gas insulated systems for partial discharge detection.

19.
J Pers Med ; 13(5)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37240912

RESUMO

This study aimed to demonstrate the laser retinopexy method through the gas bubble under a slit-lamp biomicroscope using a wide-field contact lens to treat rhegmatogenous retinal detachment (RRD) with pneumatic retinopexy (PR) and report its anatomical and functional results. This single-center, retrospective case series included RRD patients treated with PR using sulfur hexafluoride (SF6). The demographics, preoperative factors, and anatomical and functional outcomes were collected from the patient files. The single-procedure success rate of PR at postoperative 6th months was 70.8% (17/24 eyes), and the final success rate after secondary surgeries was 100%. The BCVA was better in the successful PR eyes at postoperative 3rd (p = 0.011) and 6th month (p = 0.016) than in failed eyes. No single preoperative factor was associated with PR success. The single-procedure success rate of PR using the laser retinopexy method through the gas bubble with a wide-field contact lens system seems comparable to the PR literature.

20.
Animals (Basel) ; 13(7)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37048433

RESUMO

Understanding the methane (CH4) emissions that are produced by enteric fermentation is one of the main problems to be solved for livestock, due to their GHG effects. These emissions are affected by the quantity and quality of their diets, thus, it is key to accurately define the intake and fiber content (NDF) of these forage diets. On the other hand, different emission prediction equations have been developed; however, there are scarce and uncertain results regarding their evaluation of the emissions that have been observed in forage diets. Therefore, the objectives of this study were to evaluate the effect of the NDF content of a forage diet on CH4 enteric emissions, and to evaluate the ability of models to predict the emissions from the animals that are consuming these forage diets. In total, thirty-six Angus steers (x¯ = 437 kg live weight) aged 18 months, blocked by live weight and placed in three automated feeding pens, were used to measure the enteric CH4. The animals were randomly assigned to two forage diets (n = 18), with moderate (<50%, MF) and high (>50%, HF) NDF contents. Their dry matter intake was recorded individually, and the CH4 emissions were measured using the SF6 tracer gas technique. For the model evaluation, six prediction equations were compared with 29 studies (n = 97 observations), analyzing the accuracy and precision of their estimates. The emission intensities per unit of DMI, per ADG, and per gross energy intake were significantly lower (p < 0.05) in the animals consuming the MF diet than in the animals consuming the HF diet (21.7 vs. 23.7 g CH4/kg DMI, 342 vs. 660 g CH4/kg ADG, and 6.7% vs. 7.5%, respectively), but there were no differences in the absolute emissions (p > 0.05). The best performing model was the IPCC 2006 model (r2 = 0.7, RMSE = 74.04). These results show that reducing the NDF content of a forage diet by at least 10% (52 g/kg DM) reduces the intensity of the g CH4/kg DMI by up to 8%, and that of the g CH4/kg ADG by almost half. The use of the IPCC 2006 model is suitable for estimating the CH4 emissions from animals consuming forage-based diets.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA