Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Arq. neuropsiquiatr ; Arq. neuropsiquiatr;79(9): 781-788, Sept. 2021. tab, graf, ilus
Artigo em Inglês | LILACS, UY-BNMED, BNUY | ID: biblio-1345341

RESUMO

Background: Cadaveric studies on humans have shown anatomical variabilities in the morphometric characteristics of the tentorial notch. These anatomical variations could influence the worsening of neurocritical patients. Objectives: 1) To investigate the morphometric characteristics of the tentorial notch in neurocritical patients using computed tomography (CT); 2) To investigate the correlation between tentorial notch measurements by CT and by magnetic resonance imaging (MRI); and 3) To analyze the individual variability of the tentorial notch anatomy seen in neurocritical patients. Methods: Prospective series of neurocritical patients was examined. An imaging protocol for measurements was designed for CT and MRI. The level of the agreement of the measurements from CT and MR images was established. According to the measurements found, patients were divided into different types of tentorial notch. Results: We studied 34 neurocritical patients by CT and MRI. Measurements of the tentorial notch via CT and MRI showed significant agreement: concordance correlation coefficient of 0.96 for notch length and 0.85 for maximum width of tentorial notch. Classification of tentorial notch measurements according to the criteria established by Adler and Milhorat, we found the following: 15 patients (58%) corresponded to a "short" subtype; 7 (21%) to "small"; 3 (9%) to "narrow"; 2 (6%) to "wide"; 2 (6%) to "large"; 1 (3%) to "long"; and 4 (12%) to "typical". Conclusions: The anatomical variability of the tentorial notch could be detected in vivo by means of CT scan and MRI. Good agreement between the measurements made using these two imaging methods was found.


Antecedentes: Estudios cadavéricos en humanos han mostrado variabilidad anatómica en las características morfométricas de la hendidura tentorial (HT). Estas variaciones anatómicas podrían influir en el neurodeterioro agudo de los pacientes neurocríticos. Objetivos: 1) Investigar las características morfométricas de la HT en pacientes neurocríticos mediante tomografía computarizada (TC); 2) Investigar la correlación de las mediciones de la HT realizadas por TC y resonancia magnética (RM); 3) Analizar la variabilidad individual de la anatomía de la HT observada en pacientes neurocríticos. Métodos: Se examinó una serie prospectiva de pacientes neurocríticos. Se diseñó un protocolo de imágenes para mediciones por TC y RM. Se estableció la concordancia de las mediciones realizadas mediante TC y RM. Según las mediciones encontradas, los pacientes se dividieron en diferentes tipos de HT. Resultados: Estudiamos 34 pacientes neurocríticos por TC y RM. Las mediciones de la HT por TC y RM mostraron una concordancia significativa: coeficiente de correlación de concordancia de 0,96 para la longitud de la HT y 0,85 para el ancho máximo de la HT. Clasificando las medidas de la HT de acuerdo con los criterios establecidos por Adler y Milhorat, encontramos: 15 pacientes (58%) correspondieron al subtipo "corto", 7 (21%) al "pequeño", 3 (9%) al "estrecho" ", 2 (6%) a "ancho ", 2 (6%) al "grande ", 1 (3%) al "largo" y 4 (12%) al "típico". Conclusiones: Se pudo detectar variabilidad anatómica de la HT in vivo, mediante TC y RM. Se encontró una buena concordancia en las medidas obtenidas con ambos métodos imagenológicos.


Assuntos
Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Estudos Prospectivos
2.
Oper Neurosurg (Hagerstown) ; 20(5): 484-492, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33582773

RESUMO

BACKGROUND: In recent decades, endovascular approaches have become the standard treatment for most tentorial dural arteriovenous fistulas (TDAVFs). Although endovascular treatment (EVT) is associated with better clinical outcomes, the angiographic occlusion rates are lower than those of surgical or combined approaches. OBJECTIVE: To evaluate the efficacy and safety of EVT for TDAVFs using the transarterial approach (TAA) as a first-line strategy. METHODS: Clinical and radiological data from 45 consecutive patients with TDAVFs who underwent EVT at 2 centers were retrospectively reviewed. Patient demographics and clinical and angiographic data were registered. Postprocedural and 6-mo follow-up angiographic and clinical results were evaluated. Univariable and multivariable logistic regression were performed to identify angiographic occlusion predictors after the first session and predictors of clinical complications. RESULTS: An isolated TAA was used for 40 TDAVFs (88.9%). A total of 37 (82.2%) TDAVFs were completely occluded after a single EVT session, and 44 TDAVFs (97.8%) were completely occluded after the last procedure. The presence of fewer than 5 arterial feeders was a predictor for total occlusion after the first treatment session (odds ratio [OR], 18.9; 95% CI 2.06-173.57; P = .01). Six-month angiographic control was performed in 42 patients, and all TDAVFs were occluded. Good long-term neurological outcomes were observed in 41 patients (91.1%). Clinical complications occurred in 7 (15.6%) patients. They were related to the number of accessed arteries to perform TAA (odds ratio, 2.53; 95% CI 1.10-5.86; P = .03). The procedure-related mortality rate was 2.2%. CONCLUSION: TAA is a safe and effective treatment for TDAVFs.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Embolização Terapêutica , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Dura-Máter , Humanos , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA