Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Eur Urol Oncol ; 2023 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-37599199

RESUMO

BACKGROUND: Segmentation of three-dimensional (3D) transrectal ultrasound (TRUS) images is known to be challenging, and the clinician often lacks a reliable and easy-to-use indicator to assess its accuracy during the fusion magnetic resonance imaging (MRI)-targeted prostate biopsy procedure. OBJECTIVE: To assess the effect of the relative volume difference between 3D-TRUS and MRI segmentation on the outcome of a targeted biopsy. DESIGN, SETTING, AND PARTICIPANTS: All adult males who underwent an MRI-targeted prostate biopsy for clinically suspected prostate cancer between February 2012 and July 2021 were consecutively included. INTERVENTION: All patients underwent a fusion MRI-targeted prostate biopsy with a Koelis device. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Three-dimensional TRUS and MRI prostate volumes were calculated using 3D prostate models issued from the segmentations. The primary outcome was the relative segmentation volume difference (SVD) between transrectal ultrasound and MRI divided by the MRI volume (SVD = MRI volume - TRUS volume/MRI volume) and its correlation with clinically significant prostate cancer (eg, International Society of Urological Pathology [ISUP] ≥2) positiveness on targeted biopsy cores. RESULTS AND LIMITATIONS: Overall, 1721 patients underwent a targeted biopsy resulting in a total of 5593 targeted cores. The median relative SVD was significantly lower in patients diagnosed with clinically significant prostate cancer than in those with ISUP 0-1: (6.7% [interquartile range {IQR} -2.7, 13.6] vs 8.0% [IQR 3.3, 16.4], p < 0.01). A multivariate regression analysis showed that a relative SVD of >10% of the MRI volume was associated with a lower detection rate of clinically significant prostate cancer (odds ratio = 0.74 [95% confidence interval: 0.55-0.98]; p = 0.038). CONCLUSIONS: A relative SVD of >10% of the MRI segmented volume was associated with a lower detection rate of clinically significant prostate cancer on targeted biopsy cores. The relative SVD can be used as a per-procedure quality indicator of 3D-TRUS segmentation. PATIENT SUMMARY: A discrepancy of ≥10% between segmented magnetic resonance imaging and transrectal ultrasound volume is associated with a reduced ability to detect significant prostate cancer on targeted biopsy cores.

2.
Wilderness Environ Med ; 34(2): 135-142, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36804375

RESUMO

INTRODUCTION: Point-of-care ultrasound (POCUS) is utilized in austere environments because it is lightweight, durable, battery powered, and portable. In austere settings, weight and space constraints are limitations to carrying dedicated ultrasound gel. Few studies have assessed commonly carried liquids as gel alternatives. The study objective was to assess the suitability of common food and personal care products as ultrasound coupling agents compared with that of commercial gel. METHODS: A noninferiority study compared 9 products to commercial gel. Each substance was independently tested on 2 subjects by 2 sonographers covering 8 standardized ultrasound windows. Clips were recorded, blinded, and independently graded by 2 ultrasound fellowship-trained physicians on the ability to make clinical decisions and technical details, including contrast, resolution, and artifact. A 20% noninferiority margin was set, which correlates to levels considered to be of reliably sufficient quality by American College of Emergency Physicians' guidelines. The substances included water, soap, shampoo, olive oil, energy gel, maple syrup, hand sanitizer, sunscreen, and lotion. RESULTS: A total of 300 of 318 (94%) clips met the primary endpoint of adequacy to make a clinical decision. All media, except sunscreen, were noninferior to commercial gel in the ability to make a clinical decision (α=0.05). In terms of secondary outcomes, resolution, artifact, and contrast, all substances were noninferior to commercial gel (α=0.05). The sonographers concluded that all gel alternatives' usability performed similarly to commercial gel, with the exception of energy gel. CONCLUSIONS: Of the 9 substances tested, 8 were noninferior to commercial gels for clinical decisions. Our study indicates that several POCUS gel substitutes are serviceable to produce clinically adequate images.


Assuntos
Médicos , Protetores Solares , Humanos , Ultrassonografia/métodos , Géis , Sistemas Automatizados de Assistência Junto ao Leito
3.
Eur Radiol ; 33(4): 2331-2339, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36418625

RESUMO

OBJECTIVE: To study the clinical value of three-dimensional ultrasonography (3D-US) in the morphological evaluation of rotator cuff tears (RCTs). METHODS: Based on previously published literature, RCT patterns in our study were divided into crescent, L-shaped with the remnant tendon retracted to the anterior rotator cuff (aL-shaped), L-shaped with the remnant tendon retracted to the posterior rotator cuff (pL-shaped), T-shaped (a tear pattern that is a combination of aL-shaped and pL-shaped), U-shaped, and massive type. Two radiologists prospectively assessed the tear patterns using 3D-US as well as magnetic resonance imaging (MRI) and compared these results using arthroscopy to calculate diagnostic accuracy. RESULT: Fifty-two patients (52 shoulders) were enrolled. The overall diagnostic accuracy of 3D-US in evaluating RCT patterns (82.7%, 43/52; 95% CI: 72.1-93.3%) was significantly higher (p = 0.008) than that of the MRI (57.7%, 31/52; 95% CI: 45.8-73.4%). The accuracy of 3D-US was higher than that of MRI for most types of tears (crescent: 95.0% vs. 55.0%, aL-shaped: 83.3% vs. 77.8%, pL-shaped: 50.0% vs. 25.0%, T-shaped: 75.0% vs. 0.0%, and massive type: 80.0% vs. 100.0%). The accuracies of 3D-US with respect to evaluation by the two radiologists were 84.6% (44/52) and 76.9% (40/52), and there was substantial agreement evident (κ = 0.709). The time taken by the two radiologists to reconstruct the 3D-US images and evaluate the tear pattern was < 5 min. CONCLUSION: The 3D-US can be used for the preoperative evaluation of RCT patterns, and thus be useful for the correct selection of the surgical repair technique for RCTs. KEY POINTS: • Few studies have been found exploring the value of 3D-US for the morphological evaluation of RCTs and correlated with the arthroscopic findings. • Based on previous studies on the morphological classification, anterior L shape (aL-shaped), and posterior L shape (pL-shaped) were used for the first time to describe the torn patterns of RCT.


Assuntos
Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Estudos Prospectivos , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Tendões/cirurgia , Ruptura , Ultrassonografia , Artroscopia/métodos , Imageamento por Ressonância Magnética
4.
Radiol Bras ; 55(6): 337-345, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36514679

RESUMO

Objective: To establish peripheral nerve cross-sectional area (CSA) reference values (absolute values, measures of asymmetry, and measures of focality) for healthy individuals in Brazil. Materials and Methods: Sixty-six healthy volunteers underwent high-resolution ultrasound of the peripheral nerves. We obtained CSA measurements for three peripheral nerves, at specific locations: the median nerve, in the carpal tunnel (MT); the ulnar nerve, at the cubital tunnel site (UT) and at the pre-tunnel site (UPT); and the common fibular nerve, near the fibular head (FH). We calculated the CSA indices between the same sites on different sides (ΔCSAs) and between the ulnar nerve tunnel and pre-tunnel sites on the same side (ΔTPT). Results: A total of 132 neural sites were analyzed, and the following CSA values (mean ± SD, median) were obtained: MT (6.3 ± 1.9 mm2, 6.0 mm2); UT (6.2 ± 1.6 mm2, 6.1 mm2); UPT (5.6 ± 1.7 mm2, 5.4 mm2); and FH (10.0 ± 3.7 mm2, 9.9 mm2). The ΔCSA values (mean ± SD, median) were as follows: MT (0.85 ± 0.7 mm2, 0.95); UT (0.81 ± 0.62 mm2, 0.95); UPT (0.61 ± 0.51 mm2, 0.5); and FH (1.0 ± 0.77 mm2, 1.0). The ΔTPT (mean ± SD, median) was (1.0 ± 0.8 mm2, 1.0). Conclusion: Among individuals in Brazil, peripheral nerve CSA values tend to be higher among males and to increase with aging. However, the same does not appear to hold true for the ΔCSA or the ΔTPT, the exception being the difference between the right and left UT. Differences in CSA values greater than 2.5 mm2 between sides or between sites along the same nerve can indicate asymmetry or focal thickening in neuropathy, respectively.


Objetivo: Estabelecer valores de referência da área de secção transversa (AST) dos nervos periféricos (valores absolutos e medidas de assimetria e de espessamento focal) para amostra de indivíduos brasileiros saudáveis. Materiais e Métodos: Sessenta e seis voluntários brasileiros saudáveis foram submetidos a ultrassonografia de alta resolução de nervos periféricos. As medidas da AST dos seguintes nervos periféricos foram obtidas em: mediano no túnel do carpo (MT), ulnar no túnel cubital (UT), pré-túnel ulnar (UPT) e fibular comum na cabeça da fíbula (FH). Os índices CSA foram obtidos entre os mesmos sítios em lados diferentes (ΔCSA) e entre os sítios distal e proximal do nervo ulnar (ΔTPT). Resultados: As seguintes médias ± desvio-padrão e mediana da AST foram obtidas para os 132 sítios dos nervos periféricos analisados: MT (6,3 ± 1,9 mm2; 6,0 mm2), UT (6,2 ± 1,6 mm2; 6,1 mm2), UPT (5,6 ± 1,7 mm2; 5,4 mm2) e FH (10,0 ± 3,7 mm2; 9,9 mm2). A média ± desvio-padrão e as respectivas medianas do ΔCSA em mm2 foram: 0,85 ± 0,7 [0,95] para MT, 0,81 ± 0,62 [0,95] para UT, 0,61 ± 0,51 [0,5] para UPT, 1,0 ± 0,77 [1] para FH, e 1,0 ± 0,8 [1,0] para ΔTPT. Conclusão: Os valores de AST tendem a ser maiores no sexo masculino, aumentando os valores absolutos das medianas das ASTs com o envelhecimento, mas não nos seus índices, ΔCSA e ΔTPT, exceto a diferença entre a AST dos nervos ulnares nos lados direito e esquerdo. Diferenças de valores de AST entre lados ou pontos no mesmo nervo maior que 2,5 mm2 podem significar neuropatia com assimetria e espessamento focal.

5.
Radiol. bras ; 55(6): 337-345, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422516

RESUMO

Abstract Objective: To establish peripheral nerve cross-sectional area (CSA) reference values (absolute values, measures of asymmetry, and measures of focality) for healthy individuals in Brazil. Materials and Methods: Sixty-six healthy volunteers underwent high-resolution ultrasound of the peripheral nerves. We obtained CSA measurements for three peripheral nerves, at specific locations: the median nerve, in the carpal tunnel (MT); the ulnar nerve, at the cubital tunnel site (UT) and at the pre-tunnel site (UPT); and the common fibular nerve, near the fibular head (FH). We calculated the CSA indices between the same sites on different sides (∆CSAs) and between the ulnar nerve tunnel and pre-tunnel sites on the same side (∆TPT). Results: A total of 132 neural sites were analyzed, and the following CSA values (mean ± SD, median) were obtained: MT (6.3 ± 1.9 mm2, 6.0 mm2); UT (6.2 ± 1.6 mm2, 6.1 mm2); UPT (5.6 ± 1.7 mm2, 5.4 mm2); and FH (10.0 ± 3.7 mm2, 9.9 mm2). The ∆CSA values (mean ± SD, median) were as follows: MT (0.85 ± 0.7 mm2, 0.95); UT (0.81 ± 0.62 mm2, 0.95); UPT (0.61 ± 0.51 mm2, 0.5); and FH (1.0 ± 0.77 mm2, 1.0). The ∆TPT (mean ± SD, median) was (1.0 ± 0.8 mm2, 1.0). Conclusion: Among individuals in Brazil, peripheral nerve CSA values tend to be higher among males and to increase with aging. However, the same does not appear to hold true for the ∆CSA or the ∆TPT, the exception being the difference between the right and left UT. Differences in CSA values greater than 2.5 mm2 between sides or between sites along the same nerve can indicate asymmetry or focal thickening in neuropathy, respectively.


Resumo Objetivo: Estabelecer valores de referência da área de secção transversa (AST) dos nervos periféricos (valores absolutos e medidas de assimetria e de espessamento focal) para amostra de indivíduos brasileiros saudáveis. Materiais e Métodos: Sessenta e seis voluntários brasileiros saudáveis foram submetidos a ultrassonografia de alta resolução de nervos periféricos. As medidas da AST dos seguintes nervos periféricos foram obtidas em: mediano no túnel do carpo (MT), ulnar no túnel cubital (UT), pré-túnel ulnar (UPT) e fibular comum na cabeça da fíbula (FH). Os índices CSA foram obtidos entre os mesmos sítios em lados diferentes (∆CSA) e entre os sítios distal e proximal do nervo ulnar (∆TPT). Resultados: As seguintes médias ± desvio-padrão e mediana da AST foram obtidas para os 132 sítios dos nervos periféricos analisados: MT (6,3 ± 1,9 mm2; 6,0 mm2), UT (6,2 ± 1,6 mm2; 6,1 mm2), UPT (5,6 ± 1,7 mm2; 5,4 mm2) e FH (10,0 ± 3,7 mm2; 9,9 mm2). A média ± desvio-padrão e as respectivas medianas do ∆CSA em mm2 foram: 0,85 ± 0,7 [0,95] para MT, 0,81 ± 0,62 [0,95] para UT, 0,61 ± 0,51 [0,5] para UPT, 1,0 ± 0,77 [1] para FH, e 1,0 ± 0,8 [1,0] para ∆TPT. Conclusão: Os valores de AST tendem a ser maiores no sexo masculino, aumentando os valores absolutos das medianas das ASTs com o envelhecimento, mas não nos seus índices, ∆CSA e ∆TPT, exceto a diferença entre a AST dos nervos ulnares nos lados direito e esquerdo. Diferenças de valores de AST entre lados ou pontos no mesmo nervo maior que 2,5 mm2 podem significar neuropatia com assimetria e espessamento focal.

6.
Arq. bras. cardiol ; 119(2): 319-325, ago. 2022. tab
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1383752

RESUMO

Resumo Fundamento: Sabe-se que a inflamação desempenha um papel crucial em muitas doenças, incluindo a COVID-19. Objetivo: Utilizando a dilatação fluxo-mediada (DFM), objetivou-se avaliar os efeitos da inflamação na função endotelial de pacientes com COVID-19. Métodos: Este estudo foi realizado com um total de 161 indivíduos, dos quais 80 foram diagnosticados com COVID-19 nos últimos seis meses (48 mulheres e 32 homens com idade média de 32,10±5,87 anos) e 81 eram controles saudáveis (45 mulheres e 36 homens com idade média de 30,51±7,33 anos). Os achados do ecocardiograma transtorácico e da DFM foram analisados em todos os indivíduos. Resultados com p<0,05 foram considerados estatisticamente significantes. Resultados: O ecocardiograma e a DFM do grupo COVID-19 foram realizados 35 dias (intervalo: 25-178) após o diagnóstico. Não houve diferença estatisticamente significativa nos parâmetros ecocardiográficos. Em contraste, a DFM (%) foi significativamente maior no grupo controle (9,52±5,98 versus 12,01±6,18; p=0,01). Na análise multivariada com o modelo stepwise progressivo, a DFM foi significativamente diferente no grupo controle em relação ao grupo COVID-19 (1,086 (1,026-1,149), p=0,04). O teste de correlação de Spearman indicou que a DFM (r=0,27; p=0,006) apresentou correlação positiva fraca com a presença de COVID-19. Conclusão: Os achados deste estudo apontam para disfunção endotelial induzida por COVID-19, avaliada por DFM, na fase inicial de recuperação.


Abstract Background: Inflammation is known to play a crucial role in many diseases, including COVID-19. Objective: Using flow-mediated dilatation (FMD), we aimed to assess the effects of inflammation on endothelial function in COVID-19 patients. Methods: This study was conducted with a total of 161 subjects, of whom 80 were diagnosed with COVID-19 within the last six months (comprising 48 women and 32 men with a mean age of 32.10 ± 5.87 years) and 81 were healthy controls (comprising 45 women and 36 men with a mean age of 30.51 ± 7.33 years). We analyzed the findings of transthoracic echocardiography and FMD in all subjects. All results were considered statistically significant at the level of p < 0.05. Results: The echocardiography and FMD of the COVID-19 group were performed 35 days (range: 25-178) after diagnosis. There was no statistically significant difference in echocardiographic parameters. Differently, FMD (%) was significantly higher in the control group (9.52 ± 5.98 vs. 12.01 ± 6.18, p=0.01). In multivariate analysis with the forward stepwise model, FMD was significantly different in the control group compared to the COVID-19 group (1.086 (1.026 - 1.149), p=0.04). A Spearman's correlation test indicated that FMD (r=0.27, p=0.006) had a weak positive correlation with the presence of COVID-19. Conclusion: Our findings point to COVID-19-induced endothelial dysfunction, as assessed by FMD, in the early recovery phase.

8.
J Imaging ; 8(4)2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35448238

RESUMO

Minor salivary gland ultra-high frequency ultrasonography (UHFUS) has recently been introduced for the evaluation of patients with suspected primary Sjögren's Syndrome (pSS). At present, ultrasonographic assessment of major salivary glands is performed using the Outcome Measures in Rheumatology (OMERACT) scoring system. Previous reports have explored the possibility of applying the OMERACT scoring system to minor salivary glands UHFUS, with promising results. The aim of this study was to test the inter-reader concordance in the assignment of the OMERACT score to minor salivary gland UHFUS. The study was conducted on 170 minor salivary glands UHFUS scans of patients with suspected pSS. Three independent readers performed UHFUS image evaluation. Intraclass correlation coefficient (ICC) was employed to assess inter-reader reliability. Bland and Altman analysis was employed to test the agreement with a gold standard examiner. ICC values > 0.9 were found for scores 0 and 1, while score 2 and score 3 presented ICCs of 0.873 and 0.785, respectively. The measurements performed by the three examiners were in agreement with the gold standard examiner. According to these results, UHFUS interpretation showed good inter-observer reliability, suggesting that OMERACT score can be effectively used for the evaluation of glandular alterations, even for minor salivary glands.

9.
Acta méd. peru ; 39(2): 114-119, abr.-jun. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1402998

RESUMO

RESUMEN Objetivo : Describir los resultados de la biopsia prostática transperineal por fusión de la resonancia magnética cognitiva y ultrasonido en la detección del cáncer. Materiales y métodos : Estudio de serie de casos, retrospectivo, realizado en Clínica Delgado entre julio del 2019 y octubre del 2021. Se incluyó pacientes con examen digital de próstata y/o Antígeno Prostático Específico anormal e imágenes de Resonancia Magnética de próstata con lesiones categoría PI-RADS 4 o 5. Excluyendo a pacientes con trastorno de coagulación, lesiones rectales, imposibilidad para abducción, comorbilidades para anestesia. Registramos las características clínicas, demográficas, datos de antígeno prostático específico, volumen de la próstata, lesiones PI-RADS, tasas de cáncer, complicaciones. Resultados : Se evaluaron 18 pacientes, con edad media de 69,33 ± 7,67 años. La media del antígeno prostático específico de 14,94 ± 12,42 ng/mL. La media del volumen de próstata de 57,72 ± 28,68 cc. Al examen digital de la próstata 16/18 (88.88 %) pacientes tenían sospecha de cáncer. Se hicieron biopsias con 19 núcleos en pacientes cuya RMNmP tenían lesiones con categoría de PI-RADS 4 en 6/18 (33,33 %) de los cuales 3 resultaron positivas a Adenocarcinoma y otras 3 negativas a cáncer. Biopsia con 16 núcleos en PIRADS 5 en 12/18 (66,67 %) pacientes, resultando todas positivas a cáncer. Adenocarcinoma Acinar en 15/18 (83,33 %) con Gleason 6 en 2/18 (11,11 %) y Gleason ≥ 7 en 13/18 (72,22 %) pacientes. Complicaciones leves como hematuria 1/18 (5,6 %), disuria terminal 8/18 (44,4 %) y molestia perineal 7/18 (38,8 %) y ninguna infecciosa. Conclusiones : la biopsia prostática transperineal por fusión de imágenes de resonancia magnética cognitiva y ultrasonido es factible, segura, con tasas importantes de positividad y sin infecciones.


ABSTRACT Objective : To describe the results of transperineal prostate biopsy by fusion of cognitive magnetic resonance imaging and ultrasound in the detection of cancer. Materials and methods : A retrospective case series study conducted at the Delgado Clinic between July 2019 and October 2021. Patients with digital prostate examination and/or abnormal Prostatic Specific Antigen and prostate MRI images with category lesions were included PI-RADS 4 or 5. Excluding patients with coagulation disorders, rectal injuries, impossibility for abduction, comorbidities for anesthesia. We recorded clinical and demographic characteristics, prostate-specific antigen data, prostate volume, PI-RADS lesions, cancer rates, and complications. Results: 18 patients were evaluated, with a mean age of 69.33 ± 7.67 years. The mean prostate specific antigen was 14.94 ± 12.42 ng/mL. The mean prostate volume was 57.72 ± 28.68 cc. At the digital examination of the prostate, 16/18 (88.88%) patients had suspected cancer. Biopsies with 19 cores were performed in patients whose NMRmP had lesions with PI-RADS category 4 in 6/18 (33.33%), of which 3 were positive for Adenocarcinoma and another 3 were negative for cancer. Biopsy with 16 PIRADS 5 cores in 12/18 (66.67%) patients, all of which were positive for cancer. Acinar adenocarcinoma in 15/18 (83.33%) with Gleason 6 in 2/18 (11.11%) and Gleason ≥ 7 in 13/18 (72.22%) patients. Mild complications such as hematuria 1/18 (5.6%), terminal dysuria 8/18 (44.4%) and perineal discomfort 7/18 (38.8%) and none infectious. Conclusions : transperineal prostate biopsy by fusion of cognitive magnetic resonance imaging and ultrasound is feasible, safe, with significant positivity rates and without infections.

10.
BJA Open ; 4: 100101, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37588791

RESUMO

Background: We previously showed that an ultrasound-guided i.v. catheter insertion (USGIV) simulation-based mastery learning (SBML) curriculum improves the simulated USGIV skills of paediatric anaesthesiologists. It remains unclear if improvements in simulated USGIV skills translate to improved patient care. Methods: A cohort study was conducted from August 2018 to August 2020 to evaluate paediatric anaesthesiologists' USGIV performance in the operating theatre before and after they participated in the USGIV SBML curriculum. Paediatric anaesthesiologists' use of ultrasound for successful i.v. insertion and first-attempt i.v. insertion success rate with ultrasound were compared before and after training. Results: Twenty-nine paediatric anaesthesiologists completed training. Unadjusted analysis showed a significant increase in the percentage of i.v. catheters inserted with ultrasound for successful i.v. catheter insertion (9.5-14.5%; P<0.001) and first i.v. catheter insertion attempt success with ultrasound (5.5-8.9%; P<0.001) from before to after training. Multivariable regression analysis showed higher odds of ultrasound use for a successful i.v. catheter attempt (1.79; 95% confidence interval [CI]: 1.11-2.90; P=0.018) and first-attempt success with ultrasound (4.11; 95% CI: 2.02-8.37; P<0.001) after training. Conclusions: After completing the USGIV SBML curriculum, paediatric anaesthesiologists increased their ultrasound use for successful i.v. catheter insertion and first-attempt success rate with ultrasound for patients in the operating theatre.

11.
Radiol Bras ; 54(6): 388-397, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34866699

RESUMO

In recent decades, high-resolution ultrasound (HRUS) has revolutionized the morphological and structural evaluation of peripheral nerves and muscles, revealing details of the internal structure of the neural fascicles and muscle architecture. Applications range from diagnostics to interventional procedures. The anatomy of the forearm region is complex, with several muscles and an extensive network of vessels and nerves. To guarantee the success of the evaluation by HRUS, knowledge of the normal anatomy of the region is essential. The aim of these two companion articles is to present the normal anatomy of the nerves and compartments of the forearm, as revealed by HRUS, as well as the relationships between the main vessels and nerves of the region. Part 1 aims to review the overall structure of nerves, muscles and tendons, as seen on HRUS, and that of the forearm compartments. We present a practical approach, with general guidelines and tips on how best to perform the study. Part 2 is a pictorial essay about compartment vascularization and cutaneous innervation. Knowledge of the normal anatomy of the forearm improves the technical quality of the examinations, contributing to better diagnoses, as well as improving the performance and safety of interventional procedures.

12.
Radiol Bras ; 54(6): 398-405, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34866700

RESUMO

In recent decades, high-resolution ultrasound (HRUS) has revolutionized the morphological and structural evaluation of peripheral nerves and muscles, revealing details of the internal structure of the neural fascicles and muscle architecture. Applications range from diagnostics to interventional procedures. The anatomy of the forearm region is complex, with several muscles and an extensive network of vessels and nerves. To guarantee the success of the evaluation by HRUS, knowledge of the normal anatomy of the region is essential. The aim of these two companion articles is to present the normal anatomy of the nerves and compartments of the forearm, as revealed by HRUS, as well as the relationships between the main vessels and nerves of the region. Part 1 aims to review the overall structure of nerves, muscles and tendons, as seen on HRUS, and that of the forearm compartments. We present a practical approach, with general guidelines and tips on how best to perform the study. Part 2 is a pictorial essay about compartment vascularization and cutaneous innervation. The relationships between arteries, satellite veins and nerves, as well as the relationship between cutaneous nerves and superficial veins, are demonstrated. Knowledge of the normal anatomy of the forearm improves the technical quality of the examinations, contributing to better diagnoses, as well as improving the performance and safety of interventional procedures.

13.
Radiol. bras ; 54(6): 388-397, Nov.-Dec. 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422502

RESUMO

Abstract In recent decades, high-resolution ultrasound (HRUS) has revolutionized the morphological and structural evaluation of peripheral nerves and muscles, revealing details of the internal structure of the neural fascicles and muscle architecture. Applications range from diagnostics to interventional procedures. The anatomy of the forearm region is complex, with several muscles and an extensive network of vessels and nerves. To guarantee the success of the evaluation by HRUS, knowledge of the normal anatomy of the region is essential. The aim of these two companion articles is to present the normal anatomy of the nerves and compartments of the forearm, as revealed by HRUS, as well as the relationships between the main vessels and nerves of the region. Part 1 aims to review the overall structure of nerves, muscles and tendons, as seen on HRUS, and that of the forearm compartments. We present a practical approach, with general guidelines and tips on how best to perform the study. Part 2 is a pictorial essay about compartment vascularization and cutaneous innervation. Knowledge of the normal anatomy of the forearm improves the technical quality of the examinations, contributing to better diagnoses, as well as improving the performance and safety of interventional procedures.

14.
Radiol. bras ; 54(6): 398-405, Nov.-Dec. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422503

RESUMO

Abstract In recent decades, high-resolution ultrasound (HRUS) has revolutionized the morphological and structural evaluation of peripheral nerves and muscles, revealing details of the internal structure of the neural fascicles and muscle architecture. Applications range from diagnostics to interventional procedures. The anatomy of the forearm region is complex, with several muscles and an extensive network of vessels and nerves. To guarantee the success of the evaluation by HRUS, knowledge of the normal anatomy of the region is essential. The aim of these two companion articles is to present the normal anatomy of the nerves and compartments of the forearm, as revealed by HRUS, as well as the relationships between the main vessels and nerves of the region. Part 1 aims to review the overall structure of nerves, muscles and tendons, as seen on HRUS, and that of the forearm compartments. We present a practical approach, with general guidelines and tips on how best to perform the study. Part 2 is a pictorial essay about compartment vascularization and cutaneous innervation. The relationships between arteries, satellite veins and nerves, as well as the relationship between cutaneous nerves and superficial veins, are demonstrated. Knowledge of the normal anatomy of the forearm improves the technical quality of the examinations, contributing to better diagnoses, as well as improving the performance and safety of interventional procedures.

15.
Radiol Bras ; 54(1): 27-32, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33574629

RESUMO

OBJECTIVE: To compare ultrasound images of the kidney obtained, randomly or in a controlled manner (standardizing the physical aspects of the ultrasound system), by various professionals and with different devices. MATERIALS AND METHODS: We evaluated a total of 919 images of kidneys, obtained by five professionals using two types of ultrasound systems, in 24 patients. The images were categorized into four types, by how they were acquired and processed. We compared the gray-scale median and different gray-scale ranges representative of virtual histological tissues. RESULTS: There were statistically significant differences among the five professionals, regardless of the type of ultrasound system employed, in terms of the gray-scale medians for the images obtained (p < 2.2e-16). Analyzing the four categories of images-a totally random image (without any standardization); a standardized image (with fixed values for gain, time gain control, and dynamic range); a normalized version of the random image; and a normalized version of the standardized image-we determined that the random image, even after normalization, differed quite significantly among the professionals (p = 0.006098). The analysis of the normalized version of the standardized image did not differ significantly among the professionals (p = 0.7319). CONCLUSION: Our findings indicate that a gray-scale analysis of ultrasound images of the kidney performs better when the image acquisition process is standardized and the images undergo a process of normalization.


OBJETIVO: Comparar imagens renais ultrassonográficas obtidas de maneira aleatória e controlada (padronizando fatores físicos do aparelho de ultrassom) por diferentes profissionais e aparelhos. MATERIAIS E MÉTODOS: Foram obtidos quatro tipos de imagens, de acordo com sua aquisição e processamento por cinco profissionais e dois tipos de aparelhos de ultrassonografia, em 24 pacientes, totalizando 919 imagens. Comparamos a mediana de escala de cinza e diferentes intervalos de tons de cinza representantes de tecidos histológicos virtuais. RESULTADOS: As medianas de escala de cinza de imagens renais obtidas por dois tipos de aparelhos foram estatisticamente diferentes (p < 2.2e-16). Analisando os quatro tipos de imagens, partindo de uma totalmente aleatória (sem qualquer padronização), uma padronizada (fixado o ganho, time gain control e dynamic range), e essas duas passando por um processo de normatização, obteve-se que a imagem aleatória é totalmente diversa entre os profissionais (p = 0,006098), mesmo passando pelo processo de normatização. A imagem padronizada, após passar pelo processo de normatização, apresentou resultados equivalentes, não possuindo diferença estatística (p = 0,7319). CONCLUSÃO: Constatou-se que na análise de tons de cinza deve-se usar um mesmo tipo de máquina e uma imagem em que sejam padronizados aspectos físicos, passando por um processo de normatização/padronização.

16.
Radiol. bras ; 54(1): 27-32, Jan.-Feb. 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1155222

RESUMO

Abstract Objective: To compare ultrasound images of the kidney obtained, randomly or in a controlled manner (standardizing the physical aspects of the ultrasound system), by various professionals and with different devices. Materials and Methods: We evaluated a total of 919 images of kidneys, obtained by five professionals using two types of ultrasound systems, in 24 patients. The images were categorized into four types, by how they were acquired and processed. We compared the gray-scale median and different gray-scale ranges representative of virtual histological tissues. Results: There were statistically significant differences among the five professionals, regardless of the type of ultrasound system employed, in terms of the gray-scale medians for the images obtained (p < 2.2e-16). Analyzing the four categories of images-a totally random image (without any standardization); a standardized image (with fixed values for gain, time gain control, and dynamic range); a normalized version of the random image; and a normalized version of the standardized image-we determined that the random image, even after normalization, differed quite significantly among the professionals (p = 0.006098). The analysis of the normalized version of the standardized image did not differ significantly among the professionals (p = 0.7319). Conclusion: Our findings indicate that a gray-scale analysis of ultrasound images of the kidney performs better when the image acquisition process is standardized and the images undergo a process of normalization.


Resumo Objetivo: Comparar imagens renais ultrassonográficas obtidas de maneira aleatória e controlada (padronizando fatores físicos do aparelho de ultrassom) por diferentes profissionais e aparelhos. Materiais e Métodos: Foram obtidos quatro tipos de imagens, de acordo com sua aquisição e processamento por cinco profissionais e dois tipos de aparelhos de ultrassonografia, em 24 pacientes, totalizando 919 imagens. Comparamos a mediana de escala de cinza e diferentes intervalos de tons de cinza representantes de tecidos histológicos virtuais. Resultados: As medianas de escala de cinza de imagens renais obtidas por dois tipos de aparelhos foram estatisticamente diferentes (p < 2.2e-16). Analisando os quatro tipos de imagens, partindo de uma totalmente aleatória (sem qualquer padronização), uma padronizada (fixado o ganho, time gain control e dynamic range), e essas duas passando por um processo de normatização, obteve-se que a imagem aleatória é totalmente diversa entre os profissionais (p = 0,006098), mesmo passando pelo processo de normatização. A imagem padronizada, após passar pelo processo de normatização, apresentou resultados equivalentes, não possuindo diferença estatística (p = 0,7319). Conclusão: Constatou-se que na análise de tons de cinza deve-se usar um mesmo tipo de máquina e uma imagem em que sejam padronizados aspectos físicos, passando por um processo de normatização/padronização.

19.
Int. j. cardiovasc. sci. (Impr.) ; 33(5): 479-487, Sept.-Oct. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1134415

RESUMO

Abstract Background Lung ultrasound (LUS) can detect interstitial alveolar changes confined to the subpleural region, like those described in Covid-19. Objetive To evaluate how LUS findings correlate with chest computed tomography (CT) in patients admitted to the emergency department (ED) with suspicion of Covid-19. Methods Cross-sectional study of 20 patients (median age 43 years; interquartile range, 37-63 years; 50% male). All patients underwent LUS and chest CT on the day of ED admission. Each hemithorax was divided into 6 segments with similar landmarks, and equivalent scores (sc) of lesion severity were defined for both methods. The number of affected segments on LUS (LUSseg) was divided into tertiles (0-1, 2-5, and ≥6), and compared with number of affected segments on CT (CTseg), LUSsc, CTsc, and percentage of affected lung parenchyma through visual analysis (CTvis). ANOVA or Kruskal-Wallis test for continuous variables, chi-square test for categorical variables, and receiver operating characteristic (ROC) curve analysis to define optimal cutoff points were performed. P<0.05 was considered statistically significant. Results Median LUSsc, CTsc, CTseg, and CTvis were significantly different between groups. A clear separation between groups was demonstrated; patients with <2 affected segments on LUS were defined as low risk. The ROC curve showed good discriminative power to predict ≥6 affected segments on CT, with an area under the curve (AUC) of 0.97 and 0.98 for >7 LUSsc and >3 LUSseg, respectively. Conclusion LUS findings correlate with chest CT, and can help identify patients with normal lung or minor pulmonary involvement secondary to Covid-19. Int J Cardiovasc Sci. 2020; [online].ahead print, PP.0-0


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Estudos Transversais , Triagem/métodos , Serviço Hospitalar de Emergência , COVID-19/diagnóstico
20.
Radiol Bras ; 53(1): 47-55, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32313337

RESUMO

Hepatic steatosis, or fatty liver disease, occurs due to the accumulation of lipids in hepatocytes. When it becomes chronic, lobular inflammation develops and the disease can evolve to hepatic fibrosis, liver cirrhosis, or hepatocellular carcinoma. Early diagnosis is desirable because patients diagnosed in the early stage of the disease respond better to treatment. In the early stages of fatty liver disease, the physical examination is often unremarkable. Fatty liver disease and hepatic fibrosis can be diagnosed and monitored through laboratory tests, imaging, and biopsy. Among the imaging methods, ultrasound stands out as an effective means of diagnosing and following patients with liver disease. Ultrasound used in conjunction with elastography (ultrasound elastography) has recently shown great utility in the follow-up of such patients. Ultrasound elastography studies the degree of deformation (stiffness) of an organ or lesion, so that when there is hardening, fibrosis, or cirrhosis of the liver, those alterations are well demonstrated. In this review article, we discuss the application of the different types of ultrasound elastography for liver studies: transient elastography, point shear wave elastography, and two-dimensional shear wave elastography. Although magnetic resonance elastography may also be used in the analysis of liver fibrosis, it will not be addressed in this article.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...