1.
Chinese Critical Care Medicine ; (12): 817-821, 2016.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-501993

RESUMO

Objective To explore the appropriate frequency of ventilator tube replacement by researching the influence of different ventilator circuit change frequency on ventilator-associated pneumonia (VAP).Methods A prospective randomized sampling study was conducted.The patients undergoing invasive mechanical ventilation over or equal to 3 days admitted to emergency intensive care unit (EICU) of the First Affiliated Hospital of Kunming Medical University from December 2012 to December 2015 were enrolled.The patients were divided into 3,7 and 10 days group according to the frequency of ventilator tube replacement.Bacteriology of ventilator tube and the incidence of VAP were compared among the groups.Results Ninety-eight patients were enrolled,mainly with the artificial airway of endotracheal intubation or tracheotomy,with 56 male and 42 female,aging 8 to 86 years with mean of (51.97 ± 17.56) years.There were no statistical differences in gender,age,Glasgow coma scale (GCS) score,cough function and application of glucocorticoid,enteral nutrition,atomization and sedative therapy among three groups,indicating that the risk factors among three groups were consistent.The bacteria detection rates of extension tube,breathe out tube,breathe in tube,and hydrops collection cup were 36.7%,36.7%,33.3%,and 33.3% respectively in 3 days group,and they were 73.0%,67.6%,62.2%,and 62.2% in 7 days group respectively,and were all 90.3% in 10 days group.It was showed that the bacteria detection rate in different pipe parts was almost the same with the same change frequency,and the rate was higher with the longer usage of ventilator tube (x2 values were 20.599,19.879,21.975,21.975,all P =0.000).The longer of the tube used time,the higher incidence of VAP.The incidence of VAP in 3,7,10 days groups were 26.7%,59.5% and 77.4%,respectively,but there was statistically significant difference among all groups (x2 =30.486,P < 0.001).Based on the value of 3 days group,the incidence of VAP in the 7 days group was 15.950 folds of 3 days group,and the incidence of VAP in the 10 days group was 18.333 folds of the 3 days group (both P < 0.001).Conclusion This study suggests that the longer of pipeline using time,the more serious degree of bacterial contamination of pipeline,the higher incidence of VAP.

2.
Clinical Medicine of China ; (12): 798-801, 2011.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-416378

RESUMO

Objective To explore the effect of ventilator circuit change frequency on the incidence of ventilator-associated pneumonia (VAP). Methods Patients receiving mechanical ventilation in the ICU,Department of Emergency, Respiratory Department and Department of Neurosurgery from March 2008 to September 2010 were randomized into two groups. For these two groups ,the ventilator circuit was changed once or twice a week. The recorded parameters included the clinical symptoms and signs of the ventilated patients. Samples at different parts of the circuit were collected for microbiological detection. The data were analyzed statistically. Results The incidence of VAP was 28. 30% ( 13/53 ) in twice-a-week group and 35.84%( 19/53 ) in once-a-week group. There was no significant difference between the two groups. The rates for positive microbiological detection in the circuit were 48. 16% and 44. 49% for once-a-week and twice-a-week group,respectively. No significant difference was observed ( P > 0.05 ). Moreover, there was no significant difference in terms of the microbiology positivity between different parts of the circuit(P > 0. 05 ). Gram-negative bacteria were the main pathogen of VAP with Acinetobacter baumannii ranking at the top. Conclusion Frequency of Ventilator circuit change does not influence the incidence of VAP. We suggest that the frequency for ventilator circuit change should be once a week. At the same time, the nurse staff should be trained for specific technology and the incidence of hospital infection should be controlled at multiple rings of the chain.

3.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-394339

RESUMO

Objective To investigate the method of disinfection and sterilization of ventilator tubes and accessories in order to increase the sterilization quality of them. Methods 120 ventilator tubes and accessories from ICU and emergency department were randomly dividied into the control group,and the study group. Bacteriologic tests were conducted in the two groups. Results There was significat differ-ence in bacteriologic tests between the two groups. Conclusions It is necessary to research into steriliza-tion method of ventilator tubes and accessories.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-588818

RESUMO

OBJECTIVE To analyze the relationship between the ventilator tube system and VAP.METHODS To investigate the way to use the ventilator tube system more reasonably.RESULTS To replace the ventilator tube every seven days could prevent the VAP effectively and decrease the mechanical ventilation patient′s mortality.CONCLUSIONS Decreasing the VAP incidence is a systematic and integrative work.To reinforce the management of the ventilator tube system is one of the effective methods in preventing VAP.