Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 10: 1217745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37435050

RESUMO

Background: Wide antral circumferential ablation (WACA) in comparison to ostial pulmonary vein (PV) isolation (PVI) has been attributed with improved rhythm outcome. We investigated the feasibility, lesion formation, and rhythm outcome of WACA-PVI in comparison to ostial-PVI using pulsed field ablation (PFA). Methods: Symptomatic atrial fibrillation (AF) patients (69 years, 67% male; 67% paroxysmal AF) were prospectively enrolled into our single-center registry and underwent first-time ostial-PFA or WACA-PFA, N = 15 each. In all patients, eight pulse trains (2 kV/2.5 s, bipolar, biphasic, 4× basket/flower configuration each) were delivered to each PV. In WACA-PFA, two extra pulse trains in a flower configuration were added to the anterior and posterior antrum of the PVs. For comparison of PFA lesion size, pre- and post-ablation left atrial (LA) voltage maps were acquired using a multipolar spiral catheter together with a three-dimensional electroanatomic mapping system. Results: WACA-PFA resulted in a significant larger lesion formation than ostial-PFA (45.5 vs. 35.1 cm2, p = 0.001) with bilateral overlapping butterfly shape-like lesions and concomitant posterior LA wall isolation in 73% of patients. This was not associated with increased procedure time, sedation dosage, or exposure to radiation. One-year freedom from AF recurrence was numerically higher after WACA-PFA than ostial-PFA (94% vs. 87%) but not statistically significant (p = 0.68). No organized atrial tachycardias (ATs) were observed. Ostial-PFA patients more often underwent re-ablation due to recurrent AF episodes. Conclusion: WACA-PFA is feasible and resulted in significantly wider lesion sets than ostial-PFA. Concomitant posterior LA wall isolation occurred as an epiphenomenon in the majority of patients. The WACA approach was associated with neither increased procedure and fluoroscopy times nor statistically significant differences in 1-year rhythm outcome. ATs were absent.

2.
Pacing Clin Electrophysiol ; 45(12): 1415-1418, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36272168

RESUMO

INTRODUCTION: Failure to isolate ipsilateral pulmonary veins (PV) "en bloc" by wide-area circumferential ablation (WACA) may necessitate ablation at the intervenous carina. It is unknown how this scenario impacts rates of atrial fibrillation (AF) recurrence. METHODS: A standard random-effect meta-analysis of randomized or observational studies were performed, where the outcome of first-time AF ablation was reported in patients with "en bloc" isolation of PVs by WACA as compared with those in whom ablation at the intervenous carina was needed after WACA to achieve complete isolation. RESULTS: A total of five single-center, observational studies (N = 1185) and one, multi-center randomized trial (N = 234) were enrolled. PV isolation could be achieved by WACA "en bloc" in 902/1419 (63.6%) cases. The rest required additional ablation at one or both of the left and right intervenous carinas to achieve isolation. The follow-up time after ablation ranged from 1 to 2 years in the included trials. The incidence of AF recurrence proved to be significantly lower in patients with successful "en bloc" isolation compared to those requiring carina ablation(s) to achieve complete bilateral PV isolation (MH-OR 1.89, 95% CI 1.42-2.53, p < .01) CONCLUSION: This present meta-analysis demonstrates a lower arrhythmia recurrence rate in patients with bilateral "en bloc" isolation, as compared to those who needed additional carina ablation for complete PVI. Therefore, it is imperative that every effort be made to isolate ipsilateral PVs "en bloc" during PVI.


Assuntos
Fibrilação Atrial , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
3.
Front Cardiovasc Med ; 9: 986207, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36776941

RESUMO

Background: Late reconnections (LR) of pulmonary veins (PVs) after wide antral circumferential ablation (WACA) using point-to-point radiofrequency (RF) ablation are common. Lesion size index (LSI) is a novel marker of lesion quality proposed by Ensite Precision mapping system, expected to improve PV isolation durability. This study aimed to assess the durability of LSI-guided PVI and the risk factors for LR of PVs. Methods: The prospective study included 33 patients with paroxysmal atrial fibrillation (PAF) who underwent (1) the index LSI-guided WACA procedure (with target LSI of 5.5-6.0 for anterior and 5.0-5.5 for posterior WACA segments) and (2) the 3-month protocol-mandated re-mapping procedure in all patients, irrespective of AF recurrence after the index procedure. Ablation parameters reported by Ensite mapping system were collected retrospectively. The inter-lesion distance (ILD) between all adjacent WACA lesions was calculated off-line. Association between index ablation parameters and the LRs of PVs at 3 months was analyzed. Results: The median patient age was 61 (IQR: 53-64) years and 55% of them were males. At index procedure, the first-pass WACA isolation rate was higher for the left PVs than the right PVs (64 vs. 33%, p = 0.014). In addition, a low acute reconnection rates were observed, as follows: in 12.1% of patients, in 6.1% of WACA circles, in 3.8% of WACA segments and in 4.5% of PVs. However, the 3-month remapping study revealed LR of PV in 63.6% of patients, 37.9% of WACA circles, 20.5% of WACA segments and 26.5% of PVs. The LRs were identified mostly along the left anterior WACA segment. Independent risk factors for the LR of WACA were left-sided WACA location (OR 3.216 [95%CI: 1.065-9.716], p = 0.038) and longer ILD (OR 1.256 [95%CI: 1.035-1.523] for each 1-mm increase, p = 0.021). The ILD of > 8.0 mm showed a predictive value for the LR of WACA, with the sensitivity of 84% and specificity of 46%. A single case of cardiac tamponade occurred following the re-mapping invasive procedure. No other complications were encountered. Conclusion: Although the LSI-guided PVI ensures a consistent PVI during the index procedure, LRs of PVs are still common. Besides the LSI, the PVI durability requires an optimal ILD between adjacent lesions, especially along the anterior lateral ridge.

4.
Pacing Clin Electrophysiol ; 44(4): 575-585, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33184894

RESUMO

BACKGROUND: Ablation index (AI), a novel lesion quality marker, includes contact force, time, and power of radiofrequency (RF) application, but not regional variation in wall thickness within the wide antral catheter ablation (WACA) circle. This study explored the relationships among AI target value, atrial wall thickness, and gap formation within the WACA circle in patients with paroxysmal atrial fibrillation (PAF). METHODS: We evaluated 102 consecutive patients (mean age, 65 ± 9 years) with PAF who underwent AI-guided WACA for ipsilateral pulmonary vein isolation (PVI). Each WACA circle was subdivided into eight segments, and overall 7143 RF applications were delivered, including 125 gaps in PVI ablation lines. For each RF tag within the ablation circle, we collected data on ablation lesion depth surrogates (time of application, delivery power, impedance drop, average contact force, force-time integral [FTI], and AI) and left atrial wall thickness measured by multidetector computer tomography scanning. RESULTS: The anterior and roof walls were the thickest segments of the ablation circle, in which 85.8% of gaps concentrated, while the posterior and inferior walls were the thinnest. Gap formation was significantly associated with FTI, AI, wall thickness, FTI/wall thickness, and AI/wall thickness. AI/wall thickness had the highest predictive value for gap formation, with a cutoff of 195.6 au/mm for effective ablation. CONCLUSIONS: In AI-guided PVI of PAF, AI/wall thickness by normalizing myocardial thickness variation along the WACA circle was a strong predictor of gap formation, with a target of 195.6 au/mm appearing suitable for effective ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Veias Pulmonares/diagnóstico por imagem
5.
FEBS Lett ; 593(15): 1915-1926, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31166018

RESUMO

Positioning of the division site in many bacterial species relies on the MinCDE system, which prevents the cytokinetic Z-ring from assembling anywhere but the mid-cell, through an oscillatory diffusion-reaction mechanism. MinD dimers bind to membranes and, via their partner MinC, inhibit the polymerization of cell division protein FtsZ into the Z-ring. MinC and MinD form polymeric assemblies in solution and on cell membranes. Here, we report the high-resolution cryo-EM structure of the copolymeric filaments of Pseudomonas aeruginosa MinCD. The filaments consist of three protofilaments made of alternating MinC and MinD dimers. The MinCD protofilaments are almost completely straight and assemble as single protofilaments on lipid membranes, which we also visualized by cryo-EM.


Assuntos
Adenosina Trifosfatases/química , Adenosina Trifosfatases/metabolismo , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Pseudomonas aeruginosa/metabolismo , Microscopia Crioeletrônica , Proteínas do Citoesqueleto/metabolismo , Lipídeos de Membrana/metabolismo , Modelos Moleculares , Complexos Multiproteicos/química , Conformação Proteica , Multimerização Proteica , Pseudomonas aeruginosa/química