Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Heliyon ; 10(3): e25158, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38322892

RESUMO

Objective: This study aimed to assess the current status of carcinoembryonic antigen (CEA) detection. We evaluated the correlation, consistency, and comparability of CEA results among six automated immunoassays, and combined with the results of CEA trueness verification of the Beijing Center for Clinical Laboratories (BCCL) for further analysis. Methods: Abbott Architect i2000, Beckman DxI800, Roche Cobas E601, Diasorin Liaison XL, Maccura IS1200, and Autolumo A2000 were used to detect 40 individual serum CEA samples. Taking the optimal analytical quality specifications calculated from data on biological variation as the evaluation criterion. Passing-Bablok regression and Bland-Altman analysis were performed between each assay and all-assays median values to evaluate the correlation and relative difference. The concordance correlation coefficient (CCC) was used for consistency analysis. Additionally, the trueness verification program used samples at three concentration levels to assess the bias, coefficient of variation (CV), and total error (TE) between the average measured values and the target value. Results: The Spearman's rank correlation coefficient (rs) was ≥0.996 and the CCC ranged between 0.9448 and 0.9990 for each assay vs. all-assays median. Considering the all-assays median value of each sample as a reference, there were proportional and systematic differences according to the Passing-bablok regression analysis. The relative difference of the four assays (Abbott Architect i2000, Autolumo A2000, Diasorin Liaison XL, and Maccura IS1200) met the optimal analytical quality specifications. On the other hand, Beckman DxI800 (13.2 %) and Roche Cobas E601 (-9.0 %) were only able to fulfill the desirable analytical quality specifications. The average pass rates for bias, CV, and TE of the trueness verification program were 80 %, 98 %, and 96 %, respectively. Conclusions: The six automated immunoassays vs. all-assays median have a good correlation in CEA detection. However, there is a lack of comparability of CEA results. Further improvements are needed in harmonization among CEA detections.

2.
Microbiol Spectr ; 10(6): e0059722, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36222681

RESUMO

Determination of antibody levels against the nucleocapsid (N) and spike (S) proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are used to estimate the humoral immune response after SARS-CoV-2 infection or vaccination. Differences in the design and specification of antibody assays challenge the interpretation of test results, and comparative studies are often limited to single time points per patient. We determined the longitudinal kinetics of antibody levels of 145 unvaccinated coronavirus disease 2019 (COVID-19) patients at four visits over 1 year upon convalescence using 8 commercial SARS-CoV-2 antibody assays (from Abbott, DiaSorin, Roche, Siemens, and Technoclone), as well as a virus neutralization test (VNT). A linear regression model was used to investigate whether antibody results obtained in the first 6 months after disease onset could predict the VNT results at 12 months. Spike protein-specific antibody tests showed good correlation to the VNT at individual time points (rS, 0.74 to 0.92). While longitudinal assay comparison with the Roche Elecsys anti-SARS-CoV-2 S test showed almost constant antibody concentrations over 12 months, the VNT and all other tests indicated a decline in serum antibody levels (median decrease to 14% to 36% of baseline). The antibody level at 3 months was the best predictor of the VNT results at 12 months after disease onset. The current standardization to a WHO calibrator for normalization to binding antibody units (BAU) is not sufficient for the harmonization of SARS-CoV-2 antibody tests. Assay-specific differences in absolute values and trends over time need to be considered when interpreting the course of antibody levels in patients. IMPORTANCE Determination of antibodies against SARS-CoV-2 will play an important role in detecting a sufficient immune response. Although all the manufacturers expressed antibody levels in binding antibody units per milliliter, thus suggesting comparable results, we found discrepant behavior between the eight investigated assays when we followed the antibody levels in a cohort of 145 convalescent patients over 1 year. While one assay yielded constant antibody levels, the others showed decreasing antibody levels to a varying extent. Therefore, the comparability of the assays must be improved regarding the long-term kinetics of antibody levels. This is a prerequisite for establishing reliable antibody level cutoffs for sufficient individual protection against SARS-CoV-2.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Seguimentos , Anticorpos Antivirais , Imunidade Humoral , Anticorpos Neutralizantes
3.
Front Immunol ; 13: 915338, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36059441

RESUMO

Background: Since December 2019, SARS-CoV-2 has been keeping the world in suspense. Rapid tests, molecular diagnosis of acute infections, and vaccination campaigns with vaccines are building blocks of strategic pandemic control worldwide. For laboratory diagnostics, the quantification of the antibody titer of convalescents and vaccinated patients is thus increasingly coming to the fore. Methods: Here we present an evaluation on the comparability of five serological tests on a cohort of 13 patients with mild COVID-19 disease. Also participants who were vaccinated after recovery were included in this study. All common immune methods (ELISA, CLIA, PETIA) and SARS-CoV-2 specific antigens (N-, S1- and RBD-) were specifically tracked and directly compared for up to 455 days. The titer of recovered participants was also set to the degree of symptoms during infection and the occurrence of Long-COVID. In addition, relative comparability of different serological tests, all standardized to WHO, was set in reference to the neutralizing potential of the corresponding participants. Findings: The individual immune responses over 455 days after a mild SARS-CoV-2 infection remain stable, in contrast to vaccinated participants. All sero-tests reveal comparable performance and dynamics during the study and compared well to a surrogate neutralization test. Conclusion: The information presented here will help clinicians in the daily laboratory work in the selection and evaluation of different serological tests offered. The data also will support in respect of a sero-test-based neutralization cutoff.


Assuntos
COVID-19 , Anticorpos Antivirais , COVID-19/complicações , Humanos , Pandemias , SARS-CoV-2 , Síndrome de COVID-19 Pós-Aguda
4.
Oral Oncol ; 134: 106086, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35995004

RESUMO

OBJECTIVES: The programmed cell death-ligand 1 (PD-L1) 22C3 pharmDx assay is used as a companion diagnostic test to select head and neck squamous cell carcinoma (HNSCC) patients that may benefit from treatment with the checkpoint inhibitor pembrolizumab. Because the Dako platform is not universally available, we studied the performance of a 22C3 laboratory developed test (LDT) performed on a Ventana BenchMark Ultra compared to the 22C3 pharmDx assay. MATERIALS AND METHODS: Serial sections from tissue micro arrays (TMAs) containing tumour tissue from 97 HNSCC patients were stained with the 22C3 pharmDx assay and 22C3 LDT. All TMA cores were scored by three dedicated head and neck pathologists for PD-L1 expression. RESULTS: Substantial interobserver agreement was reported for both the standardized 22C3 pharmDx assay and the 22C3 LDT (respectively Fleiss' κ 0.62, 95% CI 0.57-0.67 and 0.63, 95% CI 0.58-0.68). Concordance between the assays was almost perfect on core and patient level (respectively Weighted κ 0.84, 95% CI 0.79-0.89 and 0.84, 95% CI 0.75-0.92). Intratumor heterogeneity between the cores per patient case was similar in both assays. CONCLUSION: After validation a 22C3 LDT is non-inferior to the standardized 22C3 pharmDx assay and can be safely used to select HNSCC patients for pembrolizumab treatment.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Pulmonares , Carcinoma de Células Escamosas de Cabeça e Pescoço , Humanos , Apoptose , Antígeno B7-H1 , Biomarcadores Tumorais , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Ligantes , Reprodutibilidade dos Testes
5.
Diagnostics (Basel) ; 12(6)2022 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-35741236

RESUMO

The immunoassays used to measure anti-spike SARS-CoV-2 antibodies are widely available on the market. However, their performance in COVID-19 vaccinees is not yet adequately assessed. Our study provides a head-to-head comparison of five methods: Abbott's S1-RBD IgG, Roche's S1-RBD total antibody, Euroimmun's S1 IgG, and DiaSorin's TrimericS IgG and S1/S2 IgG assays. Testing was performed in one hundred vaccinated subjects, at eight timepoints over eight months after vaccination. The results differed substantially between methods; however, they correlated strongly and demonstrated the individuals' responses to both doses of vaccination and the waning of humoral immunity after eight months. Importantly, we encountered a high percentage of results above the assay-specific upper quantitation limit (UQL) for undiluted samples. This was the most pronounced for the Roche's and Euroimmun's assays. The Abbott's assay showed the lowest percentage of results above the UQL. We also attempted to find a common way to establish antibody concentrations that might be classified as high. However, this resulted in between 10% and 100% of such results for different methods on day 240'. This highlights the need for an assay-specific approach for adjusting the cut-offs that may indicate COVID-19 immunity.

6.
Clin Chem Lab Med ; 60(5): 766-770, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35041302

RESUMO

OBJECTIVES: The reliable identification of individuals with SARS-CoV-2 infection is the cornerstone for containing viral spread. Rapid molecular point-of-care testing (POCT) of saliva might reduce analysis time, thus increasing the efficacy of contact tracing. In this study, a new POCT RT-PCR assay for the detection of SARS-CoV-2 RNA in saliva was evaluated and compared with an already validated CE-IVD method. METHODS: An evaluation was made of 160 left-over salivary samples (27 frozen, kept at -80 °C and 133 fresh), collected using Salivette (Sarstedt, Germany). Samples were analyzed by TaqPath COVID-19 CE-IVD RT-PCR kit, QuantStudio5 Real-Time (Applied Biosystems, USA) (TaqPath) and bKIT Virus Finder COVID-19 Saliva (Hyris Global Diagnostics, Italy). Performances of three- and fivefold pooling strategies were also evaluated. Blood assay interference in saliva was also tested with Hyris. RESULTS: On using TaqPath, SARS-CoV-2 positivity was detected in 35 samples. Another 10 positive samples were artificially-generated by blind mixing of positive with negative samples. Hyris positive and negative percentages of agreement were 97.6 (95% CI: 87.2-99.9%) and 100 (95% CI: 97.0-100%), respectively. Seventeen positive pools, evaluated for threefold strategy, were all correctly determined by both systems. For the 5-pool strategy, 94.7% (18/19) of samples resulted positive with the Hyris system, and 100% with TaqPath. The presence of 1% of blood (v/v) in saliva did not interfere with the accuracy of Hyris assay. CONCLUSIONS: The sensitivity and specificity of the bKIT Virus Finder COVID-19 Saliva were optimal with respect to TaqPath. In view of the safe and straightforward pre-analytical procedure involved, and the small size of the Hyris bCube, the Hyris system can be used for POCT.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Testes Imediatos , RNA Viral/análise , RNA Viral/genética , SARS-CoV-2/genética , Saliva/química , Sensibilidade e Especificidade
7.
Diagn Microbiol Infect Dis ; 101(4): 115518, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34481324

RESUMO

We compared the performance of the Abbott Real Time SARS-CoV-2 assay (Abbott assay), Aptima™ SARS-CoV-2 assay (Aptima assay), BGI Real-Time SARS-CoV-2 assay (BGI assay), Lyra® SARS-CoV-2 assay (Lyra assay), and DiaSorin Simplexa™ COVID assay for SARS-CoV-2 detection. Residual nasopharyngeal samples (n = 201) submitted for routine SARS-CoV-2 testing by Simplexa assay during June-July 2020 and January 2021 were salvaged. Aliquots were tested on other assays and compared against the CDC 2019-nCoV Real-Time RT-PCR assay. Viral load in positive samples was determined by droplet digital PCR. Among 201 samples, 99 were positive and 102 were negative by the CDC assay. The Aptima and Abbott assays exhibited the highest positive percent agreement (PPA) at 98.9% while the BGI assay demonstrated the lowest PPA of 89.9% with 10 missed detections. Negative percent agreement for all 5 platforms was comparable, ranging from 96.1% to 100%. The performance of all five assays was comparable.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/virologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Estudos Prospectivos , Sensibilidade e Especificidade , Carga Viral , Adulto Jovem
8.
Vaccines (Basel) ; 9(8)2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-34451965

RESUMO

BACKGROUND: The introduction of the vaccination against SARS-CoV-2 infection creates the need for precise tools for the quality control of vaccination procedures, detection of poor humoral response, and estimation of the achieved protection against the disease. Thus, the study aimed to compare the results of the anti-SARS-CoV-2 tests to evaluate the application of the WHO standard unitage (the binding antibody units; BAU/mL) for a measurement of response to the vaccination. METHODS: Patients undergoing vaccination against SARS-CoV-2 with Pfizer/BioNTech BNT162b2 (BNT162b2) (n = 79), referred for SARS-CoV-2 antibody measurement prior to vaccination and 21 days after dose 1, and 8, 14, and 30 days after dose 2 were included. The sera were tested with three assays: Elecsys SARS-CoV-2 S (Roche), LIAISON® SARS-CoV-2 TrimericS IgG (DiaSorin), and SARS-CoV-2 IgG II Quant (Abbott). RESULTS: The three assays showed varying correlations at different time points in the study. The overall agreement for all samples was moderate to high (ρ = 0.663-0.902). We observed the most uniform agreement for the day of dose 2 (ρ = 0.775-0.825), while it was least consistent for day 8 (ρ = -0.131-0.693) and 14 (ρ = -0.247-0.603) after dose 2. The dynamics of changes of the SARS-CoV-2 antibody levels in patients without history of prior SARS-CoV-2 infection appears homogenous based on the Roche results, more heterogenous when considering the DiaSorin results, and in between for the Abbott results. CONCLUSIONS: The results highlight the need for further work on the international standard of measurement of SARS-CoV-2 Ig, especially in the era of vaccination. The serological assays can be useful to detect IgG/IgM antibodies to assess the response to the vaccination. However, they cannot be used interchangeably. In terms of the evaluation of the immune response to the BNT162b2 vaccine, Roche and Abbott kits appear to be more useful.

9.
Front Cell Dev Biol ; 9: 714687, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34368164

RESUMO

In the past decade, assays that profile different aspects of the epigenome have grown exponentially in number and variation. However, standard guidelines for researchers to choose between available tools depending on their needs are lacking. Here, we introduce a comprehensive collection of the most commonly used bulk and single-cell epigenomic assays and compare and contrast their strengths and weaknesses. We summarize some of the most important technical and experimental parameters that should be considered for making an appropriate decision when designing epigenomic experiments.

10.
Viruses ; 13(8)2021 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-34452381

RESUMO

The case fatality rate of rabies, nearly 100%, is one of the most unique characteristic of this ancient virus infection. The crucial role rabies virus neutralizing antibody plays in protection is both well established and explanation of why rabies serology is important. Various laboratory methods can and have been used but serum neutralization methods have long been the gold standard due to the ability to measure function (neutralization), however these methods can be difficult to perform for several reasons. Assays such as enzyme linked absorbance assays (ELISA), indirect fluorescence antibody (IFA) and more recently lateral flow methods are in use. Interpretation of results can be problematic, not only between methods but also due to modifications of the same method that can lead to misinterpretations. A common assumption in review of laboratory test results is that different methods for the same component produce comparable results under all conditions or circumstances. Assumptions and misinterpretations provide the potential for detrimental decisions, ranging from regulatory to clinically related, and most importantly what 'level' is protective. Review of the common challenges in performance and interpretation of rabies serology and specific examples illuminate critical issues to consider when reviewing and applying results of rabies serological testing.


Assuntos
Anticorpos Antivirais/sangue , Vírus da Raiva/imunologia , Raiva/diagnóstico , Raiva/imunologia , Testes Sorológicos/normas , Anticorpos Neutralizantes/sangue , Interpretação Estatística de Dados , Ensaio de Imunoadsorção Enzimática/métodos , Ensaio de Imunoadsorção Enzimática/normas , Técnica Indireta de Fluorescência para Anticorpo , Testes Hematológicos , Humanos , Testes de Neutralização/métodos , Testes de Neutralização/normas , Vírus da Raiva/isolamento & purificação , Testes Sorológicos/classificação , Testes Sorológicos/métodos
11.
Diagnostics (Basel) ; 11(8)2021 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-34441268

RESUMO

In 2019, a novel coronavirus emerged in Wuhan in the province of Hubei, China. The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) quickly spread across the globe, causing the neoteric COVID-19 pandemic. SARS-CoV-2 is commonly transmitted by droplet infection and aerosols when coughing or sneezing, as well as high-risk exposures to infected individuals by face-to-face contact without protective gear. To date, a broad variety of techniques have emerged to assess and quantify the specific antibody response of a patient towards a SARS-CoV-2 infection. Here, we report the first comprehensive comparison of five different assay systems: Enzyme-Linked Immunosorbent Assay (ELISA), Chemiluminescence Immunoassay (CLIA), Electro-Chemiluminescence Immunoassay (ECLIA), and a new Particle-Enhanced Turbidimetric Immunoassay (PETIA) for SARS-CoV-2. Furthermore, we also evaluated the suitability of N-, S1- and RBD-antigens for quantifying the SARS-CoV-2 specific immune response. Linearity and precision, overall sensitivity and specificity of the assays, stability of samples, and cross-reactivity of general viral responses, as well as common coronaviruses, were assessed. Moreover, the reactivity of all tests to seroconversion and different sample matrices was quantified. All five assays showed good overall agreement, with 76% and 87% similarity for negative and positive samples, respectively. In conclusion, all evaluated methods showed a high consistency of results and suitability for the robust quantification of the SARS-CoV-2-derived immune response.

12.
Avian Pathol ; 50(4): 357-365, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34313501

RESUMO

Despite the efforts to achieve a consistent classification scheme based on the complete S1 gene, the genetic characterization of infectious bronchitis virus (IBV) is often performed on partial S1 regions due to economic and time constraints in the diagnostic routine. Sanger sequencing remains the most common and cost-effective option even if the analysis of samples where multiple field and vaccine strain populations coexist can lead to partial or misleading results. The present study aimed to evaluate the different diagnostic outcomes of three commonly used RT-PCR methods targeting two regions of the S1 gene. A possible bias in IBV detection and characterization was investigated in relation to the adopted method, the strain concentration as well as their ratio in mixed samples. Thirty samples were prepared by artificially mixing two vaccine strains, combined at different ratios and selected among four different IBV lineages, i.e. GI-1 (Mass), GI-13 (793/B), GI-19 (QX), GI-23 (Israeli Variant 2). Sequence analysis was conducted both manually and with bioinformatic methods. The result agreement among methods, replicates and analysis approaches was statistically evaluated. Consistent results emerged among the three assays, with a few discrepancies likely caused by primer affinity and target amount. This study confirms the complexity of IBV strain identification and highlights the importance of evaluating and updating the available diagnostic assays for a reliable detection of all circulating IBV strains.


Assuntos
Vírus da Bronquite Infecciosa , Animais , Bioensaio/veterinária , Biologia Computacional , Vírus da Bronquite Infecciosa/genética
14.
J Infect Dis ; 224(7): 1209-1218, 2021 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-32147687

RESUMO

BACKGROUND: Evaluations of human immunodeficiency virus (HIV) curative interventions require reliable and efficient quantification of replication-competent latent reservoirs. The "classic" quantitative viral outgrowth assay (QVOA) has been regarded as the reference standard, although prohibitively resource and labor intensive. We compared 6 "next-generation" viral outgrowth assays, using polymerase chain reaction or ultrasensitive p24 to assess their suitability as scalable proxies for QVOA. METHODS: Next-generation QVOAs were compared with classic QVOA using single leukapheresis-derived samples from 5 antiretroviral therapy-suppressed HIV-infected participants and 1 HIV-uninfected control; each laboratory tested blinded batches of 3 frozen and 1 fresh sample. Markov chain Monte Carlo methods estimated extra-Poisson variation at aliquot, batch, and laboratory levels. Models also estimated the effect of testing frozen versus fresh samples. RESULTS: Next-generation QVOAs had similar estimates of variation to QVOA. Assays with ultrasensitive readout reported higher infectious units per million values than classic QVOA. Within-batch testing had 2.5-fold extra-Poisson variation (95% credible interval [CI], 2.1-3.5-fold) for next-generation assays. Between-laboratory variation increased extra-Poisson variation to 3.4-fold (95% CI, 2.6-5.4-fold). Frozen storage did not substantially alter infectious units per million values (-18%; 95% CI, -52% to 39%). CONCLUSIONS: The data offer cautious support for use of next-generation QVOAs as proxies for more laborious QVOA, while providing greater sensitivities and dynamic ranges. Measurement of latent reservoirs in eradication strategies would benefit from high throughput and scalable assays.


Assuntos
Infecções por HIV , HIV-1/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Latência Viral , Replicação Viral , Terapia Antirretroviral de Alta Atividade , Linfócitos T CD4-Positivos , Estudos de Casos e Controles , Infecções por HIV/tratamento farmacológico , Infecções por HIV/virologia , Transcriptase Reversa do HIV , HIV-1/isolamento & purificação , Humanos , Leucaférese , Carga Viral , Replicação Viral/fisiologia
15.
Front Genet ; 12: 790445, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35251117

RESUMO

An array-based genotyping approach has been the standard practice for genome-wide association studies (GWASs); however, as sequencing costs plummet over the past years, ultra low-coverage whole-genome sequencing (ulcWGS <0.5× coverage) has emerged as a promising alternative that provides superior genomic coverage with substantial reduction of genotyping cost. To evaluate the potential utility of ulcWGS, we performed a whole-genome sequencing (WGS) of 72 European individuals to a target coverage of 0.4× and compared its performance with the widely used Infinium Global Screening Multi-Disease Array (GSA-MD). We showed that the number of variants captured by ulcWGS is comparable with imputed GSA-MD platform, particularly for low-frequency (95.5%) and common variants (99.9%), with high imputation R2 accuracy (mean 0.93 for SNPs and 0.86 for indels). Using deep-coverage 30× WGS as the "truth" genotypes, we found that ulcWGS has higher overall nonreference genotype concordance compared with imputed GSA-MD for both SNPs (0.90 vs. 0.88) and indels (0.86 vs. 0.83). In addition, ulcWGS proved to be as sensitive as the genotyping-based method in sex imputation and ancestry prediction producing similar principal component (PC) scores. Our findings provide important evidence that the cost efficient ulcWGS of <0.5× generates high genotype accuracy, outperforming the standard genotyping arrays, making it an attractive alternative to the array-based method in next-generation GWAS design.

16.
Molecules ; 27(1)2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-35011274

RESUMO

The ABTS and DPPH methods are among the most popular assays of antioxidant activity determination. Attempts to adapt them to different analytes and the search for the highest values of antioxidant activity has resulted in a large variety of assay conditions to be presented in the literature, including the way the measurement is made. This makes it difficult to relate the results to real oxidation systems, and often makes it impossible to compare them. Such a comparison is limited in advance by the use of stable radicals that do not exist in nature and that react differently from those generated in food or in vivo. Therefore, it is important to introduce measures aimed at standardizing the conditions of the activity assay, including reaction time and several reaction environments suitable for testing different groups of compounds. In this study, we used natural antioxidants of various structures: phenolic acids, flavonoids, peptides and corresponding amino acids, ascorbic acid and α-tocopherol, and also synthetic analogues of selected compounds. The curves of dependence of the measured absorbance on the concentration of antioxidants were described, the ranges of linearity were determined, and the value of the error made when reading in various ranges of dependencies was estimated. We also determined and compared the activity values using two popular methods (IC50 and TEAC), taking into account different environments and reaction times. Based on the collected data, recommendations were formulated regarding the reaction conditions adapted to the studies of individual groups of antioxidants, and unified reaction times were proposed. Taking into account the state before reaching the equilibrium of antioxidants reacting in a complex manner, this approach may introduce a simplified reference to the competing reaction that occurs in reality.


Assuntos
Antioxidantes/farmacologia , Benzotiazóis , Bioensaio/métodos , Compostos de Bifenilo , Picratos , Ácidos Sulfônicos , Antioxidantes/química , Benzotiazóis/antagonistas & inibidores , Compostos de Bifenilo/antagonistas & inibidores , Relação Dose-Resposta a Droga , Concentração de Íons de Hidrogênio , Oxirredução , Picratos/antagonistas & inibidores , Ácidos Sulfônicos/antagonistas & inibidores
17.
Cancer Genet ; 243: 11-18, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32197218

RESUMO

As fusion detection NGS techniques are adopted by clinical labs, assay performance comparison is urgently needed. We compared four fusion-detection assay platforms on a pilot cohort of 24 prostate cancer samples: (1) Oncomine Comprehensive panel v3; (2) AmpliSeq comprehensive panel v3; (3) The solid tumor panel of FusionPlex; and (4) The human oncology panel of QIAseq. The assays were compared for the detection of different types of fusion based on whether the partner gene or the breakpoints are known. All assays detected fusion with known gene partners and known breakpoint, represented by TMPRSS2-ERG. A fusion with known partners but unknown breakpoint, TMPRSS2-ETV4, was reported by OCAv3 and FusionPlex, but not by AICv3 because the specific breakpoint was not in the manifest, nor by QIAseq since the panel did not target the exact exons involved. For fusion with unknown partners, FusionPlex identified the largest number of ETV1 fusions because it had the highest exon coverage for ETV1. Among these, SNRPN-ETV1 and MALAT1-ETV1, were novel findings. To determine reportability of low-level calls of highly prevalent fusions, such as TMPRSS2-ERG, we propose the use of percent fusion reads over total number of reads per sample instead of the fusion read count.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala/instrumentação , Proteínas de Fusão Oncogênica/isolamento & purificação , Neoplasias de Próstata Resistentes à Castração/diagnóstico , Análise de Sequência de RNA/instrumentação , Reações Falso-Positivas , Humanos , Masculino , Proteínas de Fusão Oncogênica/genética , Projetos Piloto , Próstata/patologia , Neoplasias de Próstata Resistentes à Castração/genética , Neoplasias de Próstata Resistentes à Castração/patologia , Valores de Referência , Reprodutibilidade dos Testes , Software
19.
Histopathology ; 76(2): 191-200, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31243779

RESUMO

AIMS: Programmed death-ligand 1 (PD-L1) expression by tumour cells (TC) is a mechanism for tumour immune escape through down-regulation of antitumour T cell responses and is a target for immunotherapy. PD-L1 status as a predictor of treatment response has led to the development of multiple biomarkers with different reference cut-offs. We assessed pathologist consistency in evaluating PD-L1 immunopositivity by examining the inter- and intraobserver agreement using various antibody clones and different cancer types. METHODS AND RESULTS: PD-L1 expression in TC and immune cells (IC) was manually scored in 27 head and neck squamous cell carcinoma (HSCC), 30 urothelial carcinoma (UC) and breast carcinoma (BC) using three commercial clones (SP263, SP142, 22C3) and one platform-independent test (E1L3N). For interobserver agreement, PD-L1 status was evaluated blindly by three pathologists. For intraobserver agreement, PD-L1 expression was re-evaluated following a wash-out period. Intraclass correlation coefficient (ICC), overall percentage agreement (OPA) and κ-values were calculated. Using clinical algorithms, the percentage of PD-L1-positive cases in HSCC, BC and UC were 15-81%, 47-67% and 7-43%, respectively. The percentage of PD-L1 positive cases relied heavily on the algorithm/cut-off values used. Almost perfect interobserver agreement was achieved using SP263 and E1L3N in HSCC, 22C3, SP142 and E1L3N in BC and 22C3 in UC. The SP142 clone in UC and HSCC showed moderate agreement and was associated with lower ICC and decreased intraobserver concordance. CONCLUSIONS: Excellent inter- and intraobserver agreement can be achieved using SP263, 22C3 and E1L3N, whereas PD-L1 scoring using SP142 clone is associated with a higher level of subjectivity.


Assuntos
Anticorpos Monoclonais/imunologia , Antígeno B7-H1/metabolismo , Neoplasias da Mama/diagnóstico , Carcinoma de Células de Transição/diagnóstico , Neoplasias de Cabeça e Pescoço/diagnóstico , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico , Neoplasias da Bexiga Urinária/diagnóstico , Algoritmos , Antígeno B7-H1/antagonistas & inibidores , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Carcinoma de Células de Transição/metabolismo , Carcinoma de Células de Transição/patologia , Estudos de Coortes , Feminino , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Imuno-Histoquímica , Variações Dependentes do Observador , Patologistas , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Análise Serial de Tecidos , Neoplasias da Bexiga Urinária/metabolismo , Neoplasias da Bexiga Urinária/patologia , Urotélio/patologia
20.
J Appl Microbiol ; 128(3): 893-898, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31749279

RESUMO

AIMS: Faecal microbiota transplantation (FMT) consists of the infusion of faeces from a healthy donor to the gastrointestinal tract of a recipient patient to treat disease associated with alterations in gut microbiota. The objective of this article was to describe laboratory workflow of an FMT laboratory to provide tips for preparing the faecal suspensions to be infused. METHODS AND RESULTS: Twenty-stool solutions obtained from ten donors were prepared using two different protocols: magnet plate emulsion (MPE) and Seward StomacherTM Emulsion (SSE). We evaluated parameters such as preparation time, handiness, and aerobic and anaerobic microbial count. For three donors, we monitored bacterial counts after defrosting at different time-points. MPE requires more time than SSE. In terms of microbial load, both methods showed similar values, with small and statistically differences (P ≤ 0·05) regarding anaerobes in favour of SSE. Frozen aliquots showed the same bacterial load values after defrosting. CONCLUSION: Although both methods allow an easy and available preparation of a stool suspension, SSE seems more suitable, particularly for stool banking. Aerobic and anaerobic species are preserved with both protocols; and safety for laboratory operators is guaranteed. SIGNIFICANCE AND IMPACT OF THE STUDY: In recent years, FMT has become a fascinating and interesting subject. Nevertheless, there are no real guidelines describing laboratory facilities and procedures. This paper aims to be a useful and simple guide to increase the number FMT centres as much possible.


Assuntos
Transplante de Microbiota Fecal , Fezes/microbiologia , Laboratórios/normas , Manejo de Espécimes/métodos , Carga Bacteriana , Bancos de Espécimes Biológicos/normas , Microbioma Gastrointestinal , Humanos , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...