1.
Appl Radiat Isot ; 192: 110550, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36436227

RESUMO

A water-cooled XY-type beam current monitor was designed, manufactured and assembled in a cyclotron accelerator beam transport line. Tests were performed, demonstrating that apparatus is an instrument of great assistance in proton beam position. The XY-type beam current monitor has been widely used in liquid target irradiations, employing irradiation system which were originally designed for irradiations on 18 MeV cyclotron accelerator (Cyclone 18, IBA) only, however, with this apparatus, the target may be exchanged between the 30 MeV (Cyclone 30, IBA) and 18 MeV cyclotrons.


Assuntos
Ciclotrons , Radioatividade
2.
Sensors (Basel) ; 22(14)2022 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-35890815

RESUMO

In a Heavy Ion Beam Diagnostic (HIBD), the plasma potential is obtained by measuring the energy of the secondary ions resulting from beam-plasma collisions by an electrostatic energy analyzer with split-plate detector (SPD), which relates the secondary ion beam energy variation to its position determined by the difference in currents between the split plates. Conventionally, the data from SPD are analyzed with the assumption that the secondary beam current is uniform. However, the secondary beam presents an effective projection of the primary beam, the current of which, as a rule, has a bell-like non-uniform profile. This paper presents: (i) the general features of the secondary beam profile formation, considered in the simplistic approximation of the circular primary beam and the secondary ions that emerge orthogonal to the primary beam axis, (ii) details of spit-plate detection and the influence of the secondary beam non-uniformity on plasma potential measurements, (iii) supported experimental data from the tokamak ISTTOK HIBD for primary and secondary beam profiles and the SPD transfer characteristic, obtained for the 90° cylindrical energy analyzer (90° CEA) and (iv) the implementation of a multiple cell array detector (MCAD) with dedicated resolution for the measurements of secondary beam profile and MCAD operation in multi-split-plate detection mode for direct measurements of the SPD transfer characteristic.

3.
Sensors (Basel) ; 22(11)2022 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-35684659

RESUMO

The unique arrangement of the heavy-ion beam diagnostic in ISTTOK enables one to measure the evolution of temperature, density and pressure-like profiles in normal and AC discharges. The fast chopping beam technique provided the possibility to reduce the noise on the measurements of the plasma pressure-like profile and for the precise control of the plasma column position in real time. The consequent improvements in S/N levels allowed the observation of the effects of runaway beam magnetic energy conversion into plasma local heating. In addition, it made it possible to follow the evolution of the quiescent plasma maintained during AC transitions when the plasma current is null. The use of a new operation mode in the cylindrical energy analyzer provided an improved resolution up to five times in determining the fluctuations of the plasma potential as compared to the normal operation mode. Such analyzer is extremely compact (250 mm × 250 mm × 120 mm) and provides a unique geometry in order to cover the whole plasma diameter. The detector configuration choice gives the possibility for the simultaneous measurements of plasma poloidal magnetic field, plasma pressure-like and plasma potential profiles together with their fluctuations.

4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(2): 102-105, 2019 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-30977605

RESUMO

er to detect the beam quality of the SC200 superconducting cyclotron,measure the beam at the extraction reference and the acceptance of the accelerator is realized.This article mainly introduces the design that use the scintillation screen at the extraction reference to measure the beam profile,position and use the Faraday cup to measure the current intensity with 2.5 level accuracy.The remoted controlling of probes and the acquisition and processing of signal based on LabVIEW and PLC.


Assuntos
Terapia com Prótons , Terapia com Prótons/instrumentação
5.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-772554

RESUMO

er to detect the beam quality of the SC200 superconducting cyclotron,measure the beam at the extraction reference and the acceptance of the accelerator is realized.This article mainly introduces the design that use the scintillation screen at the extraction reference to measure the beam profile,position and use the Faraday cup to measure the current intensity with 2.5 level accuracy.The remoted controlling of probes and the acquisition and processing of signal based on LabVIEW and PLC.


Assuntos
Terapia com Prótons
6.
J Biol Phys ; 29(2-3): 303-7, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23345848

RESUMO

The radiation source ELBE atDresden-Rossendorf is centered around asuperconducting ELectron accelerator ofhigh Brilliance and low Emittance (ELBE) which produces electronbeams up to 40 MeV. This new facility delivers secondary radiation of differentkinds. Special emphasis will be given tothe production of intense THz radiationfrom its Free-Electron Lasers (FEL). This radiation will be usedfor various research activities including the life sciences. Two additionalfemtosecond Ti:sapphire laser systems allowto exploit different methods of THzgeneration for such investigations.