Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.875
Filtrar
1.
Am J Obstet Gynecol ; 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38955323

RESUMO

BACKGROUND: Elagolix, an approved oral treatment for endometriosis-associated pain, has been associated with hypoestrogenic effects when used as monotherapy. Hormonal add-back therapy has the potential to mitigate these effects. OBJECTIVE: To evaluate efficacy, tolerability, and bone density outcomes of elagolix 200 mg twice daily with 1 mg estradiol /0.5 mg norethindrone acetate (add-back) therapy once daily compared with placebo in premenopausal women with moderate-to-severe endometriosis-associated pain. STUDY DESIGN: This ongoing, 48-month, phase 3 study consists of a 12-month, double-blind period, with randomization 4:1:2 to elagolix 200 mg twice daily with add-back therapy, elagolix 200 mg twice daily monotherapy for 6 months followed by elagolix with add-back therapy, or placebo. The co-primary endpoints were proportion of patients with clinical improvement (termed "responders") in dysmenorrhea and nonmenstrual pelvic pain at month 6. We report 12-month results on efficacy of elagolix with add-back therapy versus placebo in reducing dysmenorrhea, nonmenstrual pelvic pain, dyspareunia, and fatigue. Tolerability assessments include adverse events and change from baseline in bone mineral density. RESULTS: A total of 679 patients were randomized to elagolix with add-back therapy (n=389), elagolix monotherapy (n=97), or placebo (n=193). Compared with patients randomized to placebo, a significantly greater proportion of patients randomized to elagolix with add-back therapy responded with clinical improvement in dysmenorrhea (62.8% versus 23.7%; P≤.001) and nonmenstrual pelvic pain (51.3% versus 36.8%; P≤.001) at 6 months. Compared with placebo, elagolix with add-back therapy produced significantly greater improvement from baseline in 7 hierarchically ranked secondary endpoints including dysmenorrhea (months 12, 6, 3), nonmenstrual pelvic pain (months 12, 6, 3), and fatigue (months 6) (all P<.01). Overall, the incidence of adverse events was 73.8% with elagolix plus add-back therapy and 66.8% with placebo. The rate of severe and serious adverse events did not meaningfully differ between treatment groups. Study drug discontinuations associated with adverse events were low in patients receiving elagolix with add-back therapy (12.6%) and those receiving placebo (9.8%). Patients randomized to elagolix monotherapy exhibited decreases from baseline in bone mineral density of -2.43% (lumbar spine), -1.54% (total hip), and -1.78% (femoral neck) at month 6. When add-back therapy was added to elagolix at month 6, the change from baseline in bone mineral density remained in a similar range of -1.58% to -1.83% at month 12. However, patients who received elagolix plus add-back therapy from baseline exhibited little change from baseline in bone mineral density (<1% change) at months 6 and 12. CONCLUSION: Compared with placebo, elagolix with add-back therapy resulted in significant, clinically meaningful improvement in dysmenorrhea, nonmenstrual pelvic pain, and fatigue at 6 months that continued until month 12 for both dysmenorrhea and nonmenstrual pelvic pain. Elagolix with add-back therapy was generally well tolerated. Loss of bone mineral density at 12 months was greater in patients who received elagolix with add-back therapy than those who received placebo. However, the change in bone mineral density with elagolix plus add-back therapy was < 1% and was attenuated compared with bone loss observed with elagolix monotherapy.

2.
Ann Rheum Dis ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38964754

RESUMO

OBJECTIVES: Metabolic changes are crucially involved in osteoclast development and may contribute to bone degradation in rheumatoid arthritis (RA). The enzyme aconitate decarboxylase 1 (Acod1) is known to link the cellular function of monocyte-derived macrophages to their metabolic status. As osteoclasts derive from the monocyte lineage, we hypothesised a role for Acod1 and its metabolite itaconate in osteoclast differentiation and arthritis-associated bone loss. METHODS: Itaconate levels were measured in human peripheral blood mononuclear cells (PBMCs) of patients with RA and healthy controls by mass spectrometry. Human and murine osteoclasts were treated with the itaconate derivative 4-octyl-itaconate (4-OI) in vitro. We examined the impact of Acod1-deficiency and 4-OI treatment on bone erosion in mice using K/BxN serum-induced arthritis and human TNF transgenic (hTNFtg) mice. SCENITH and extracellular flux analyses were used to evaluate the metabolic activity of osteoclasts and osteoclast progenitors. Acod1-dependent and itaconate-dependent changes in the osteoclast transcriptome were identified by RNA sequencing. CRISPR/Cas9 gene editing was used to investigate the role of hypoxia-inducible factor (Hif)-1α in Acod1-mediated regulation of osteoclast development. RESULTS: Itaconate levels in PBMCs from patients with RA were inversely correlated with disease activity. Acod1-deficient mice exhibited increased osteoclast numbers and bone erosion in experimental arthritis while 4-OI treatment alleviated inflammatory bone loss in vivo and inhibited human and murine osteoclast differentiation in vitro. Mechanistically, Acod1 suppressed osteoclast differentiation by inhibiting succinate dehydrogenase-dependent production of reactive oxygen species and Hif1α-mediated induction of aerobic glycolysis. CONCLUSION: Acod1 and itaconate are crucial regulators of osteoclast differentiation and bone loss in inflammatory arthritis.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38965037

RESUMO

Osteoporosis (OP) is a systemic skeletal disease that is characterized by low bone mass and increased fracture risk. This article explores the potential of probiotics as an adjunctive approach for the prevention and management of OP. It has been well established that the gut microbiota (GM), a complex community of microbes, plays an important role in bone health. The gut dysbiosis is linked with a higher risk of OP. However, the consumption of probiotics in adequate amounts restores gut health thus improving bone health. Probiotics may influence bone metabolism through enhanced calcium absorption, reduced inflammation, and increased bone formation. The animal and human studies demonstrate the positive effects of probiotics on bone health parameters like reduced osteoclastogenesis, bone resorption markers, osteoblast, osteocyte apoptosis, and increased bone mineral density and expression of osteoprotegerin. The current evidence suggests that probiotics can be used as an adjunctive approach along with the existing therapies for the prevention and management of OP.

4.
Odontology ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38970721

RESUMO

The aim of this study was to compare the level of bone mass in digital orthopantomograms in two populations (medieval and current) using two radiomorphometric indexes, and to correlate the mandibular bone mass value, in the medieval mandible population, with stable isotope data δ13C and δ15N. An observational, cross-sectional, and analytical study on mandibles from two diachronic groups, 15 mandibles from the medieval settlement of La Torrecilla (Granada, Spain) and 15 mandibles from current patients at the Faculty of Dentistry of the University of Granada (Spain), matched by age and sex was conducted. The bone mass density was determined using the Mandibular Cortical Width Index (MCW) and the Mandibular Panoramic Index (PMI) in digital panoramic radiographs. In the medieval group, the values of bone mass density were correlated with those of two stable isotopes (δ13C and δ15N). The mean value of MCW in mm in the medieval group was 3.96 ± 0.60 (mean ± standard deviation) and in the current group was 4.02 ± 1.01. The PMI was 0.33 ± 0.06 and 0.35 ± 0.08 in the medieval and current groups respectively, with similar results in both groups (p = 0.820 and p = 0.575). A negative correlation was found between both morphometric indices and the δ15N isotope (rs = 0.56, p = 0.030 and rs = 0.61, p = 0.016, respectively). The bone mass density in mandibles belonging to the two compared populations, determined by two quantitative radiomorphometric indices, is similar. Within the medieval population, there is an inverse correlation between the δ15N value and bone mass density.

5.
Ann Rheum Dis ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38986577

RESUMO

OBJECTIVES: Bone remodelling is a highly dynamic process dependent on the precise coordination of osteoblasts and haematopoietic-cell derived osteoclasts. Changes in core metabolic pathways during osteoclastogenesis, however, are largely unexplored and it is unknown whether and how these processes are involved in bone homeostasis. METHODS: We metabolically and transcriptionally profiled cells during osteoclast and osteoblast generation. Individual gene expression was characterised by quantitative PCR and western blot. Osteoblast function was assessed by Alizarin red staining. immunoresponsive gene 1 (Irg1)-deficient mice were used in various inflammatory or non-inflammatory models of bone loss. Tissue gene expression was analysed by RNA in situ hybridisation. RESULTS: We show that during differentiation preosteoclasts rearrange their tricarboxylic acid cycle, a process crucially depending on both glucose and glutamine. This rearrangement is characterised by the induction of Irg1 and production of itaconate, which accumulates intracellularly and extracellularly. While the IRG1-itaconate axis is dispensable for osteoclast generation in vitro and in vivo, we demonstrate that itaconate stimulates osteoblasts by accelerating osteogenic differentiation in both human and murine cells. This enhanced osteogenic differentiation is accompanied by reduced proliferation and altered metabolism. Additionally, supplementation of itaconate increases bone formation by boosting osteoblast activity in mice. Conversely, Irg1-deficient mice exhibit decreased bone mass and have reduced osteoproliferative lesions in experimental arthritis. CONCLUSION: In summary, we identify itaconate, generated as a result of the metabolic rewiring during osteoclast differentiation, as a previously unrecognised regulator of osteoblasts.

6.
Br J Sports Med ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997148

RESUMO

Orthopaedic and sports medicine clinicians can improve outcomes for transgender patients by understanding the physiological effects of gender-affirming hormone therapy (GAHT). This narrative review investigated the role of GAHT on bone mineral density, fracture risk, thromboembolic risk, cardiovascular health and ligament/tendon injury in this population. A search from the PubMed database using relevant terms was performed. Studies were included if they were levels 1-3 evidence. Due to the paucity of studies on ligament and tendon injury risk in transgender patients, levels 1-3 evidence on the effects of sex hormones in cisgender patients as well as basic science studies were included for these two topics. This review found that transgender patients on GAHT have an elevated fracture risk, but GAHT has beneficial effects on bone mineral density in transgender women. Transgender women on GAHT also have an increased risk of venous thromboembolism, stroke and myocardial infarction compared with cisgender women. Despite these elevated risks, studies have found it is safe to continue GAHT perioperatively for both transgender women and men undergoing low-risk operations. Orthopaedic and sports medicine clinicians should understand these unique health considerations for equitable patient care.

7.
J Clin Med ; 13(13)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38999260

RESUMO

Background: Reverse total shoulder arthroplasty (RSA) significantly impacts deltoid length, tension, and structure. Studies have extensively investigated various modifications in deltoid characteristics, such as perfusion, elasticity, caliber, histological changes, and strength post-RSA. However, to date, there is a notable absence of research evaluating changes in bone mineral density (BMD) at the deltoid muscle origin after the RSA procedure. Methods: A retrospective analysis of a consecutive series of RSAs performed between May 2011 and May 2022 was conducted. Inclusion criteria comprised primary RSAs with both preoperative and last follow-up shoulder CT scans and a minimum follow-up of 12 months. Trabecular attenuation measured in Hounsfield units (HU) was calculated using a rapid region-of-interest (ROI) method. BMD analysis involved segmenting three ROIs in both pre- and postoperative CT scans of each patient: the acromion, clavicle, and spine of the scapula. Results: A total of 44 RSAs in 43 patients, comprising 29 women and 14 men, were included in this study. The mean follow-up duration was 49 ± 22.64 months. Significant differences were observed between preoperative and postoperative HU values in all analyzed regions. Specifically, BMD increased in the acromion and spine, while it decreased in the clavicle (p-values 0.0019, <0.0001, and 0.0088, respectively). Conclusions: The modifications in shoulder biomechanics and, consequently, deltoid tension post-implantation result in discernible variations in bone quality within the analyzed regions. This study underscores the importance of thorough preoperative patient planning. By utilizing CT images routinely obtained before reverse shoulder replacement surgery, patients at high risk for fractures of the acromion, clavicle, and scapular spine can be identified.

8.
Cureus ; 16(6): e61782, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38975416

RESUMO

Aesthetics are one of the primary goals of restorative care. Teeth that are traumatized in the anterior maxilla usually avulse or require extraction due to fractures. Rehabilitation is challenging in such a therapeutic state since it presents several anatomical and aesthetic issues. There are circumstances in which traditional implant placement is problematic. There must be enough bone for implant placement to be uneventful and successful. Other surgical therapies may be necessary in addition to implant placement for certain operations, such as extensive grafting, direct or indirect sinus lifts, and nerve lateralization. Certain procedures are required for these operations but are not always achievable. Because single-piece basal implants provide immediate temporization and loading while receiving adequate anchoring from the basal cortical bone, they have been extensively used to rehabilitate resorbed ridges. This case report demonstrates the placement of the basal implant in the anterior zone.

9.
Clin Exp Dent Res ; 10(4): e917, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38973208

RESUMO

OBJECTIVES: To determine the correlation between the primary implant stability quotient and the implant percussion sound frequency. MATERIALS AND METHODS: A total of 14 pigs' ribs were scanned using a dental cone beam computed tomography (CBCT) scanner to classify the bone specimens into three distinct bone density Hounsfield units (HU) value categories: D1 bone: >1250 HU; D2: 850-1250 HU; D3: <850 HU. Then, 96 implants were inserted: 32 implants in D1 bone, 32 implants in D2 bone, and 32 implants in D3 bone. The primary implant stability quotient (ISQ) was analyzed, and percussion sound was recorded using a wireless microphone connected and analyzed with frequency analysis software. RESULTS: Statistically significant positive correlations were found between the primary ISQ and the bone density HU value (r = 0.719; p < 0.001), and statistically significant positive correlations between the primary ISQ and the percussion sound frequency (r = 0.606; p < 0.001). Furthermore, significant differences in primary ISQ values and percussion sound frequency were found between D1 and D2 bone, as well as between D1 and D3 bone. However, no significant differences were found in primary ISQ values and percussion sound frequency between D2 and D3 bone. CONCLUSION: The primary ISQ value and the percussion sound frequency are positively correlated.


Assuntos
Densidade Óssea , Tomografia Computadorizada de Feixe Cônico , Implantes Dentários , Percussão , Animais , Suínos , Percussão/instrumentação , Densidade Óssea/fisiologia , Som , Costelas/cirurgia , Implantação Dentária Endóssea/métodos , Implantação Dentária Endóssea/instrumentação , Retenção em Prótese Dentária
10.
Clin Anat ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984382

RESUMO

Appropriate management of radial head fractures is integral to prevent long-term consequences like chronic pain and loss of motion. Advanced imaging systems, like micro-computed tomography (µCT), are valuable for understanding radial head fracture patterns as they utilize micrometer scale resolution to define important parameters of bone health like cortical density and trabecular thickness. The purpose of this study was to identify and describe the structural morphology of the radial head utilizing µCT. Nine fresh-frozen cadaveric human radii were divided into four equal quadrants, based, and labeled as posteromedial, posterolateral, anteromedial, and anterolateral. Quadrants were scanned with a SCANCO MicroCT40 with both cortical and cancellous bone density measurements at a resolution of 36.0 µm. Bone density, direct trabecular number, and trabecular thickness were recorded as milligrams of hydroxyapatite/cm3. A one-way repeated measures ANOVA was performed to compare the bone densities, trabecular number, and trabecular thickness of each of the four quadrants (p < 0.05). The posteromedial quadrant contained substantially more bone than other quadrants. Significantly greater bone densities were found in the posteromedial quadrant (148.1 mg of HA/cm3) compared to the anteromedial quadrant (54.6 mg of HA/cm3), posterolateral quadrant (137.5 mg of HA/cm3) compared to the anteromedial quadrant (54.6 mg of HA/cm3), and posterolateral quadrant (137.5 mg of HA/cm3) compared to the anterolateral quadrant (58.1 mg of HA/cm3). The trabecular number was not significantly different between quadrants. Trabecular thickness was significantly lower in the anterolateral (0.1417 mg of HA/cm3) and anteromedial (0.1416 mg of HA/cm3) quadrants compared to the posteromedial (0.1809 mg of HA/cm3) quadrant. The posterior half of the radial head was found to have a higher density of columns and arches compared to the anterior half. The microstructure of trabecular bone in the distal radius forms columns, struts, and arches, which allow for efficient transmission of stress through the bone. The microstructure of the radial head has similar microarchitecture to the distal radius with the present study identifying the presence of columns and arches in the radial head. These structures, along with trabecular density, in the posterior radial head may explain the lower incidence of fractures involving the posterior half of the radial head. Furthermore, our study supports the idea that the high incidence of fractures involving the anterolateral quadrant is due to microarchitecture characteristics and the relative lack of supportive structures compared to other areas. The novel insight gained from this study will aid in the development of advanced interventions for preventative measures and better treatment of radial head fractures like more satisfactory purchase when screws are directed towards the denser posteromedial quadrant.

11.
Artigo em Inglês | MEDLINE | ID: mdl-39015028

RESUMO

This comprehensive review critically examines the detrimental impacts of endocrine-disrupting chemicals (EDCs) on bone health, with a specific focus on substances such as bisphenol A (BPA), per- and polyfluoroalkyl substances (PFASs), phthalates, and dioxins. These EDCs, by interfering with the endocrine system's normal functioning, pose a significant risk to bone metabolism, potentially leading to a heightened susceptibility to bone-related disorders and diseases. Notably, BPA has been shown to inhibit the differentiation of osteoblasts and promote the apoptosis of osteoblasts, which results in altered bone turnover status. PFASs, known for their environmental persistence and ability to bioaccumulate in the human body, have been linked to an increased osteoporosis risk. Similarly, phthalates, which are widely used in the production of plastics, have been associated with adverse bone health outcomes, showing an inverse relationship between phthalate exposure and bone mineral density. Dioxins present a more complex picture, with research findings suggesting both potential benefits and adverse effects on bone structure and density, depending on factors such as the timing and level of exposure. This review underscores the urgent need for further research to better understand the specific pathways through which EDCs affect bone health and to develop targeted strategies for mitigating their potentially harmful impacts.

12.
Turk J Orthod ; 37(2): 72-78, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38952227

RESUMO

Objective: This retrospective clinical study aimed to evaluate the maturation of intramaxillary and circummaxillary suture systems and cervical vertebral maturation as predictors of the skeletal response achieved by rapid maxillary expansion (RME). Methods: A Digital Imaging and Communication in Medicine dataset of 20 patients (mean age: 15.55 years) prior (T0) and after (T1: 3.5±0.5 months) to RME were retrieved from the archive and analyzed. Bone density values of midpalatal suture (MPS), zygomaticomaxillary suture (ZMS), zygomaticotemporal suture (ZTS), pterygopalatine suture (PPS), and transverse palatine suture (TPS) were measured. The cervical vertebral maturational stages (CVS) were examined. The linear distances between the most lateral points of the piriform apertures were measured as the anterior reference, and the medial margins of the greater palatine foramina on the axial slice were chosen as the posterior reference. The difference at T1-T0 was calculated as the skeletal response to RME at anterior and posterior skeletal references. Spearman's rho rank and Kruskal-Wallis tests were used. Results: Mean density values of ZMS, PPS, ZTS, TPS, MPS-Anterior, and MPS-Posterior were 922.81, 807.44, 753.83, 640.77, 661.13, and 604.59 HU, respectively. Mean linear changes in anterior and posterior skeletal expansion were 2.93±1.78 and 1.93±2.52 mm. There was no significant relationship between maturation indicators and skeletal response. Significant relationships were found between CVS and MPS density and CVS and circummaxillary suture average density (p≤0.05). Conclusion: Sutural density showed significant variations among CVSs. Although there was no correlation between skeletal response and density measurements, sutural density was found to be a promising indicator for future studies.

13.
J Dent Sci ; 19(3): 1846-1849, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035264

RESUMO

Surgical intervention for medication-related jaw osteonecrosis (MRONJ) is currently the main treatment method, offering a higher healing rate than conservative approaches. However, the management of bony defects after sequestrectomy remains a challenging issue due to poor vascularization from the drug effect. The use of pedicled buccal fat pad (PBFP) for filling bone defects has become common and effective but is limited to the posterior maxillary region. To add to the advantages of the buccal fat pad, we explored a novel treatment approach using a free buccal fat pad (FBFP) to fill bone defects other than the posterior maxilla. While the FBFP has been employed in oral defect reconstruction, currently published cases have been utilized in recipient sites with good blood supply. There has yet to be any usage in poor vascularization defects like MRONJ. This article describes that the FBFP was used to fill the surgical defects of 8 patients who were diagnosed with MRONJ and who underwent sequestrectomy and saucerization. During follow-up visits, there was excellent wound healing and no significant tissue depression. Based on successful treatment experiences, FBFP is a reliable therapeutic option for the management of poor vascularization defects like MRONJ treated through surgical intervention.

14.
J Dent Sci ; 19(3): 1452-1460, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035342

RESUMO

Background/purpose: Osteoclast differentiation is crucial for orchestrating both tooth movement and the maintenance of bone density. Therefore, the current study sought to explore the impact of low-level laser therapy (LLLT) on osteoclast differentiation, functional gene expression, molecular signaling pathways, and orthodontic tooth movement in clinical settings. Materials and methods: The RAW 264.7 cell line served as the precursor for osteoclasts, and these cells underwent irradiation using a 808-nm LLLT. Osteoclast differentiation was assessed through tartrate-resistant acid phosphatase (TRAP) staining. Functional gene expression levels were evaluated using real-time quantitative polymerase chain reaction (RT-qPCR) while signaling molecules were examined through Western blot analysis. In the clinical study, 12 participants were enrolled. Their tooth movement was monitored using a TRIOS desktop scanner. Bone density measurements were conducted using Mimics software, which processed cone-beam computed tomography (CBCT) images exported in Digital Imaging and Communications in Medicine (DICOM) format. Results: We found that LLLT effectively promoted receptor activator of nuclear factor-κB ligand (RANKL)-dependent osteoclast differentiation and the expression of osteoclast functional genes, including matrix metallopeptidase 9 (MMP9), nuclear factor of activated T-cells cytoplasmic 1(NFATc1), tartrate-resistant acid phosphatase (TRAP) and cathepsin K (CTSK) in RAW264.7 cells. Clinically, the cumulative tooth movement over 90 days was significantly higher in the laser group than in the control group. Conclusion: Our research demonstrates that LLLT not only significantly promotes osteoclast differentiation but is also a valuable adjunct in orthodontic therapy.

15.
JSES Int ; 8(4): 851-858, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035663

RESUMO

Background: Several studies have reported proximal bone resorption in stemless and press-fit short-stem humeral implants for anatomic total shoulder arthroplasty. The purpose of this biomechanical study was to evaluate implant and cortical bone micromotion of a cortical rim-supported stemless implant compared to a press-fit short stem implant during cyclic loading and static compression testing. Methods: Thirty cadaveric humeri were assigned to 3 groups based on a previously performed density analysis, adopting the metaphyseal and epiphyseal and inferior supporting bone densities for multivariate analyses. Implant fixation was performed in stemless implant in low bone density (SL-L, n = 10) or short stem implant in low bone density (Stem-L, n = 10) and in stemless implant in high bone density (SL-H, n = 10). Cyclic loading with 220 N, 520 N, and 820 N over 1000 cycles at 1.5 Hz was performed with a constant valley load of 25 N. Optical recording allowed for spatial implant tracking and quantification of cortical bone deformations in the medial calcar bone region. Implant micromotion was measured as rotational and translational displacement. Load-to-failure testing was performed at a rate of 1.5 mm/s with ultimate load and stiffness measured. Results: The SL-H group demonstrated significantly reduced implant micromotion compared to both low-density groups (SL-L: P = .014; Stem-L: P = .031). The Stem-L group showed significantly reduced rotational motion and variance in the test results at the 820-N load level compared to the SL-L group (equal variance: P = .012). Implant micromotion and reversible bone deformation were significantly affected by increasing load (P < .001), metaphyseal cancellous (P = .023, P = .013), and inferior supporting bone density (P = .016, P = .023). Absolute cortical bone deformation was significantly increased with stemless implants in lower densities and percentage reversible bone deformation was significantly higher for the SL-H group (21 ± 7%) compared to the Stem-L group (12 ± 6%, P = .017). Conclusion: A cortical rim-supported stemless implant maintained proximally improved dynamic bone loading in variable bone densities compared to a press-fit short stem implant. Biomechanical time-zero implant micromotion in lower bone densities was comparable between short stem and stemless implants at rehabilitation load levels (220 N, 520 N), but with higher cyclic stability and reduced variability for stemmed implantation at daily peak loads (820 N).

16.
Curr Oncol ; 31(6): 3064-3072, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38920717

RESUMO

The purpose of this study is to compare three commonly used radiotherapy fractionation schedules for bone metastasis in terms of clinical and radiological effectiveness. A total of 93 patients with osteolytic bone metastasis were randomized to receive 8 Gyin a single fraction (group A), 20 Gy in 5 fractions (group B) and 30 Gy in 10 fractions (group C). Changes in bone density were measured using the Relative Electron Density (RED) type corrected by Thomas (pe = HU/1.950 + 1.0), where HU is Hounsfield Units. Pain response was assessed according to the Brief Pain Inventory tool. Quality of life was estimated using the EORTC QLQ-C30 and the MD Anderson Symptom (MDAS) tools.After RT, RED, together with the parameters of EORTC QLQ-C30, MDAS and SAT, significantly increased in all groups (p < 0.001).Specifically, the increase of RED was higher in group C compared to group Athree months post-RT (p = 0.014). Group C was also superior to group A in terms of QoL and BPI three months post-treatment. Multifractionated radiotherapy for osteolytic bone metastasis is superior to single fraction radiotherapy in terms of improvement in quality of life and bone remineralization three months post-RT.


Assuntos
Neoplasias Ósseas , Fracionamento da Dose de Radiação , Qualidade de Vida , Humanos , Neoplasias Ósseas/secundário , Neoplasias Ósseas/radioterapia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Osteólise/radioterapia , Adulto , Densidade Óssea , Resultado do Tratamento
17.
Ann Med Surg (Lond) ; 86(6): 3216-3221, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38846880

RESUMO

Background: Implant success and the state of the surrounding bone require multiple measures, especially in humans, and this study aimed to identify the development of the state of the latter by means of radiographic examination performed during the period of osseointegration as well as investigate the changes in bone density that occur after implant installation and 2 months after functional loading. Implant success rates are affected by bone density at the implant site. Therefore, understanding changes in bone density after dental implant placement is essential, as it correlates with subsequent implant success. Materials and methods: Digital radiographs of 28 implants were taken and evaluated at four intervals: preoperatively, 1 and 3 months postoperatively, and 2 months following placement of the permanent prosthesis. Gray values were measured in different areas around the implants through analyzing X-ray images and measuring bone density around the implants using EzDent - 2D software. The aim of this study was to investigate changes in bone density around implants in three regions: apex, neck, and body, as well as to record average density values during the observation period by measuring digital image gray levels (the gray values of the digital radiographs). This was conducted to determine local bone densities in dental implant recipient sites and to study changes in local bone densities at different intervals, preoperatively and postoperatively and after placement of the prosthesis. Results: A decrease was observed in gray values proportional to reference values 1-month after implant insertion, but these increased at 3 months after insertion and continued to rise 2 months after placement of the prosthesis in the apical, body, and neck regions of the implant. Conclusion: Sensor-tuned radiography can be used as an effective method to support clinical follow-ups as well as measure changes in bone densities around implants in critical cases.

18.
Asian Spine J ; 18(3): 336-345, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38917853

RESUMO

STUDY DESIGN: A retrospective study. PURPOSE: To investigate the correlation between Hounsfield unit (HU) values measured by chest computed tomography (CT) and dual-energy Xray absorptiometry (DXA) T-scores. HU-based thoracolumbar (T11 and T12) cutoff thresholds were calculated for a cohort of Chinese patients. OVERVIEW OF LITERATURE: For patients with osteoporosis, the incidence of fractures in the thoracolumbar segment is significantly higher than that in other sites. However, most current clinical studies have focused on L1. METHODS: This retrospective study analyzed patients who underwent chest CT and DXA at our hospital between August 2021 and August 2022. Thoracic thoracolumbar segment HU values, lumbar T-scores, and hip T-scores were computed for comparison, and thoracic thoracolumbar segment HU thresholds suggestive of potential bone density abnormalities were established using receiver operating characteristic curves. RESULTS: In total, 470 patients (72.4% women; mean age, 65.5±12.3 years) were included in this study. DXA revealed that of the 470 patients, 90 (19%) had osteoporosis, 180 (38%) had reduced osteopenia, and 200 (43%) had normal bone mineral density (BMD). To differentiate osteoporosis from osteopenia, the HU threshold was established as 105.1 (sensitivity, 54.4%; specificity, 72.2%) for T11 and 85.7 (sensitivity, 69.4%; specificity, 61.1%) for T12. To differentiate between osteopenia and normal BMD, the HU threshold was 146.7 for T11 (sensitivity, 57.5%; specificity, 84.4%) and 135.7 for T12 (sensitivity, 59.5%; specificity, 80%). CONCLUSIONS: This study supports the significance of HU values from chest CT for BMD assessment. Chest CT provides a new method for clinical opportunistic screening of osteoporosis. When the T11 HU is >146.7 or the T12 HU is >135.7, additional osteoporosis testing is not needed unless a vertebral fracture is detected. If the T11 HU is <105.1 or the T12 HU is <85.7, further DXA testing is strongly advised. In addition, vertebral HU values that fall faster than those of the T11 and L1 vertebrae may explain the high incidence of T12 vertebral fractures.

19.
Eur J Radiol ; 177: 111521, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38850722

RESUMO

PURPOSE: To develop two bone status prediction models combining deep learning and radiomics based on standard-dose chest computed tomography (SDCT) and low-dose chest computed tomography (LDCT), and to evaluate the effect of tube voltage on reproducibility of radiomics features and predictive efficacy of these models. METHODS: A total of 1508 patients were enrolled in this retrospective study. LDCT was conducted using 80 kVp, tube current ranging from 100 to 475 mA. On the other hand, SDCT was performed using 120 kVp, tube current ranging from 100 to 520 mA. We developed an automatic thoracic vertebral cancellous bone (TVCB) segmentation model. Subsequently, 1184 features were extracted and two classifiers were developed based on LDCT and SDCT images. Based on the diagnostic results of quantitative computed tomography examination, the first-level classifier was initially developed to distinguish normal or abnormal BMD (including osteoporosis and osteopenia), while the second-level classifier was employed to identify osteoporosis or osteopenia. The Dice coefficient was used to evaluate the performance of the automated segmentation model. The Concordance Correlation Coefficients (CCC) of radiomics features were calculated between LDCT and SDCT, and the performance of these models was evaluated. RESULTS: Our automated segmentation model achieved a Dice coefficient of 0.98 ± 0.01 and 0.97 ± 0.02 in LDCT and SDCT, respectively. Alterations in tube voltage decreased the reproducibility of the extracted radiomic features, with 85.05 % of the radiomic features exhibiting low reproducibility (CCC < 0.75). The area under the curve (AUC) using LDCT-based and SDCT-based models was 0.97 ± 0.01 and 0.94 ± 0.02, respectively. Nonetheless, cross-validation with independent test sets of different tube voltage scans suggests that variations in tube voltage can impair the diagnostic efficacy of the model. Consequently, radiomics models are not universally applicable to images of varying tube voltages. In clinical settings, ensuring consistency between the tube voltage of the image used for model development and that of the acquired patient image is critical. CONCLUSIONS: Automatic bone status prediction models, utilizing either LDCT or SDCT images, enable accurate assessment of bone status. Tube voltage impacts reproducibility of features and predictive efficacy of models. It is necessary to account for tube voltage variation during the image acquisition.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38851525

RESUMO

BACKGROUND: Stemless implants were introduced to prevent some of the stem-related complications associated with the total shoulder arthroplasty. Although general requirements for receiving these implants include good bone quality conditions, little knowledge exists about how bone quality affects implant performance. The goal of this study was to evaluate the influence of age-induced changes in bone density, as a metric of bone quality, in the primary stability of five anatomic stemless shoulder implants using 3D finite element (FE) models. METHODS: The implant designs considered were based on the Global Icon, Sidus, Simpliciti, SMR, and Inhance stemless implants. Shoulder arthroplasties were virtually simulated in Solidworks. The density distributions of 20 subjects from two age groups, 20 to 40 and 60 to 80 years old, were retrieved from medical image data and integrated into three-dimensional FE models of a single humerus geometry, developed in Abaqus, to avoid confounding factors associated with geometric characteristics. For the designs which do not have a solid collar covering the entire bone surface, i.e., the Sidus, Simpliciti, SMR, and Inhance implants, contact and non-contact conditions between the humeral head component and bone were considered. Primary stability was evaluated through the assessment of micromotions at the bone-implant interface considering eight load cases related to rehabilitation activities and demanding tasks. Three research variables, considering 20 µm, 50 µm, and 150 µm as thresholds for osseointegration, were used for a statistical analysis of the results. RESULTS: The decreased bone density registered for the 60-80 age group led to larger micromotions at the bone-implant interface when compared to the 20-40 age group. The Global Icon-based and Inhance-based designs were the least sensitive to bone density, whereas the Sidus-based design was the most sensitive to bone density. The establishment of contact between the humeral head component and bone for the implants that do not have a solid collar led to decreased micromotions. DISCUSSION: Although the age-induced decline in bone density led to increased micromotions in the FE models, some stemless shoulder implants presented good overall performance regardless of the osseointegration threshold considered, suggesting that age alone may not be a contraindication to anatomic total shoulder arthroplasty. If only primary stability is considered, the results suggested superior performance for the Global Icon-based and Inhance-based designs. Moreover, the humeral head component should contact the resected bone surface when feasible. Further investigation is necessary to combine these results with the long-term performance of the implants and allow more precise recommendations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA