RESUMO
Infective endocarditis (IE) associated with implantable cardiac devices (ICD) is a serious disease with high mortality rates. The increased number of ICD implants has led to increased ICD infection rates. The aim of this study was to characterize clinical, laboratory profiles and the prognosis of cardiac-device-related endocarditis (CDIE), as well as to identify predictors of in-hospital death. A total of 274 patients with IE were included in a prospective cohort (2007-2019). From these, 82 patients (30%) had CDIE (46 pacemakers, 23 cardioverter defibrillators, and 13 cardiac resynchronization therapy devices). Predisposed conditions; clinical, laboratory and echocardiographic parameters; etiologic agents; and in-hospital outcomes were evaluated. The mean age was 55.8 ± 16.4 years, where 64.6% were male. Among the clinical manifestations at diagnosis, the most prevalent were heart failure (67.9%), fever (60.5%), anorexia/hyporexia (44.4%), and heart murmur (37.5%). The median serum C-reactive protein (CRP) level at diagnosis was 63 mg/L (interquartile range [IQR] 20-161). Etiological agents were identified through positive blood cultures in 55% of cases. The main etiologic agents were negative-coagulase staphylococci (19.5%) and Staphylococcus aureus (18.3%). Vegetation was identified in 74 patients (90.1%). In-hospital mortality was 28%. CRP concentrations at diagnosis were identified as markers of disease severity (odds ratio [OR] 1.006; 95%CI 1.001-1.011; p = 0.016), and the worsening of heart failure was associated with unfavorable outcomes (OR 3.105; 95%CI 1.397-6.902; p = 0.005). Unlike what is traditionally accepted, CDIE does not have a better prognosis.
RESUMO
Background: A subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to a transvenous implantable cardio defibrillator (TV-ICD). An S-ICD reduces the risk of transvenous lead placement. However, further research is required to determine how S-ICDs affect patients with hypertrophic cardiomyopathy (HCM). In this study, we investigated the comparative efficacy and safety of S-ICDs versus TV-ICDs in HCM. Methods: On December 6th, 2023, we performed a comprehensive search of the PubMed, Embase, Scopus, and Cochrane databases to identify randomized clinical trials (RCTs) and observational studies comparing S-ICDs with TV-ICDs in HCM patients published from 2004 until 2023. No language restrictions were applied. The primary outcome was appropriate shocks (AS), with inappropriate shocks (IAS), and device-related complications considered as secondary outcomes. Odds ratios (ORs) and 95% confidence intervals (CIs) were pooled using a random effects model. The ROBINS-I tool was used to assess the risk of bias of the studies. Results: The search yielded 1,114 records. Seven studies comprising 4,347 HCM patients were included, of whom 3,325 (76.0%) had TV-ICDs, and 1,022 (22.6%) had S-ICDs. There were 2,564 males (58.9%). The age range was from 39.1 to 49.4 years. Compared with the TV-ICD group, the S-ICD cohort had a significantly lower incidence of device-related complications (OR 0.52; 95% CI: 0.30-0.89; P=0.02; I2=4%). Contrastingly, there were no statistically significant differences in the occurrences of AS (OR 0.49; 95% CI: 0.22-1.08; P=0.08; I2=75%) and IAS (OR 1.03; 95% CI: 0.57-1.84; P=0.93; I2=65%) between the two device modalities. In the analysis of the overall risk of bias in the studies, we found 42% of them with several, 28% with moderate, and 14% with low risk of bias. Conclusions: In HCM patients, S-ICDs were associated with a lower incidence of device-associated problems than TV-ICDs. AS and IAS incidence rates were similar between groups. These findings may assist clinicians in determining the most suitable device for treating patients with HCM.
RESUMO
Arrhythmogenic cardiomyopathy is a biventricular disease in which the effect on the left ventricle can be either equivalent to or more severe than that on the right ventricle. It is a rare disease due to its low reported prevalence and typically becomes clinically evident during the second to fourth decade of life. It represents 4% of sudden cardiac death cases referred for autopsy and 10% of cases of unexplained cardiac arrest. We present a challenging case report of a 68-year-old man who arrived at the emergency room with chest discomfort, palpitations, and light-headedness before a syncopal episode with urinary incontinence. During monitoring, ventricular tachycardia was detected and was treated with cardioversion. However, a follow-up electrocardiogram revealed low QRS voltages in limb leads and T-wave inversion in the left precordial leads. The patient underwent a transthoracic echocardiogram and a gadolinium-based magnetic resonance imaging study to evaluate the possibility of acute decompensated heart failure. Both imaging studies revealed low ejection fraction and systolic dysfunction in both right and left ventricles. Furthermore, in the late gadolinium enhancement study, extensive left ventricular subepicardial enhancement with septal predominance in a ring pattern and an irregular morphology of the right ventricular free wall were observed. A diagnosis of biventricular arrhythmogenic cardiomyopathy was established based on the 2020 Padua Criteria. Although there is not a recognized classification within these criteria to establish its subtype, in our case there was a left ventricular predominance due to the presence of additional left ventricular categories.
RESUMO
Resumen Introducción: El desfibrilador automático implantable (DAI) transvenoso es el tratamiento de elección para la prevención de muerte súbita (MS) cardiaca por arritmias ventriculares malignas. Su uso se puede ver limitado cuando existe infección del sistema de estimulación o en población pediátrica donde representa un reto por diversas razones, incluyendo: las mínimas dimensiones del sistema venoso de los niños, la longitud de los electrodos, el tamaño del generador, así como por la complejidad anatómica en casos de cardiopatía congénita asociada. Objetivo: El presente artículo tiene por objetivo presentar la primera serie de casos de pacientes mexicanos a los cuales se les implantó un DAI subcutáneo (DAI-SC) como terapia para la prevención de MS. Métodos: Se presentan los cuatro primeros casos que fueron implantados en el Instituto Nacional de Cardiología Ignacio Chávez con un DAI-SC (Emblem, Boston Scientific, EE.UU.), tres de ellos eran pacientes pediátricos, incluyendo el primer implante de este tipo de dispositivo en un paciente pediátrico en América Latina. Las técnicas de tres y dos incisiones fueron empleadas bajo anestesia general. Resultados: Se realizó el implante exitoso con técnica de tres incisiones en los dos primeros casos y con técnica de dos incisiones en los dos últimos casos. Se corroboró el adecuado funcionamiento del dispositivo en sala, con la verificación de terapia apropiada (65 J) de la fibrilación ventricular inducida mediante estimulación a 50 Hz. No hubo complicaciones inmediatas. Un paciente presentó descargas apropiadas a los dos meses del implante. En el seguimiento, un niño desarrolló erosión de la piel a nivel de la curva del electrodo en el esternón, sin datos de infección. En quirófano se resecó la piel dañada, se retiró el barril y la seda de fijación, se realizó lavado quirúrgico y se volvió a cerrar la piel, logrando así evitar el retiro del sistema. Conclusiones: El DAI-SC es una terapia alternativa al DAI endovenoso y puede ser considerado de primera elección en aquellos casos que no requieran de estimulación ventricular, incluyendo pacientes pediátricos. Pueden ocurrir complicaciones cutáneas, pero no representan una amenaza como las complicaciones venosas de los DAI convencionales.
Abstract Introduction: The transvenous implantable cardioverter defibrillator (ICD) is the treatment of choice for the prevention of sudden cardiac death (SCD). Its use could be restricted when device-related infections occurs or in the pediatric population. In the later, an ICD represents a challenge, due to the minimal dimensions of the venous system in children, the length of the electrodes, the size of the generator, as well as the anatomical complexity in cases with associated congenital heart disease. Objective: This article presents the first Mexican patients with a subcutaneous ICD (SC-ICD) implant as a therapy for the prevention of SCD. Methods: The first four cases were implanted at the Ignacio Chávez National Institute of Cardiology with a SC-ICD (Emblem, Boston Scientific, USA), three of them were pediatric patients, including the first implant of this type of device in a pediatric patient in Latin America. The 3-incision and 2-incision techniques were used under general anesthesia. Results: A successful implantation was obtained with the 3-incision technique in the first 2 cases and the last 2 with the 2-incision technique. Proper functioning of the device was corroborated in the operating room with proof of appropriate therapy (65 J) for ventricular fibrillation induced with 50 Hz stimulation. No immediate complications were observed. One patient had appropriate shocks two months after the implant. During follow-up, one child developed skin erosion at the level of the curve of the electrode on the sternum, with no signs of infection. In the operating room, the damaged skin was resected, the barrel and the fixation silk were removed, surgical lavage was performed, and the skin was closed again, thus avoiding removal of the system. Conclusions: The SC-ICD is an alternative therapy to the transvenous ICD. It can be considered first choice in subjects who do not require ventricular pacing, including pediatric patients. Skin complications can occur but do not pose a threat as venous complications of conventional ICDs.
RESUMO
INTRODUCTION: The transvenous implantable cardioverter defibrillator (ICD) is the treatment of choice for the prevention of sudden cardiac death (SCD). Its use could be restricted when device-related infections occurs or in the pediatric population. In the later, an ICD represents a challenge, due to the minimal dimensions of the venous system in children, the length of the electrodes, the size of the generator, as well as the anatomical complexity in cases with associated congenital heart disease. OBJECTIVE: This article presents the first Mexican patients with a subcutaneous ICD (SC-ICD) implant as a therapy for the prevention of SCD. METHODS: The first four cases were implanted at the Ignacio Chávez National Institute of Cardiology with a SC-ICD (Emblem, Boston Scientific, USA), three of them were pediatric patients, including the first implant of this type of device in a pediatric patient in Latin America. The 3-incision and 2-incision techniques were used under general anesthesia. RESULTS: A successful implantation was obtained with the 3-incision technique in the first 2 cases and the last 2 with the 2-incision technique. Proper functioning of the device was corroborated in the operating room with proof of appropriate therapy (65 J) for ventricular fibrillation induced with 50 Hz stimulation. No immediate complications were observed. One patient had appropriate shocks two months after the implant. During follow-up, one child developed skin erosion at the level of the curve of the electrode on the sternum, with no signs of infection. In the operating room, the damaged skin was resected, the barrel and the fixation silk were removed, surgical lavage was performed, and the skin was closed again, thus avoiding removal of the system. CONCLUSIONS: The SC-ICD is an alternative therapy to the transvenous ICD. It can be considered first choice in subjects who do not require ventricular pacing, including pediatric patients. Skin complications can occur but do not pose a threat as venous complications of conventional ICDs.
INTRODUCCIÓN: El desfibrilador automático implantable (DAI) transvenoso es el tratamiento de elección para la prevención de muerte súbita (MS) cardiaca por arritmias ventriculares malignas. Su uso se puede ver limitado cuando existe infección del sistema de estimulación o en población pediátrica donde representa un reto por diversas razones, incluyendo: las mínimas dimensiones del sistema venoso de los niños, la longitud de los electrodos, el tamaño del generador, así como por la complejidad anatómica en casos de cardiopatía congénita asociada. OBJETIVO: El presente artículo tiene por objetivo presentar la primera serie de casos de pacientes mexicanos a los cuales se les implantó un DAI subcutáneo (DAI-SC) como terapia para la prevención de MS. MÉTODOS: Se presentan los cuatro primeros casos que fueron implantados en el Instituto Nacional de Cardiología Ignacio Chávez con un DAI-SC (Emblem, Boston Scientific, EE.UU.), tres de ellos eran pacientes pediátricos, incluyendo el primer implante de este tipo de dispositivo en un paciente pediátrico en América Latina. Las técnicas de tres y dos incisiones fueron empleadas bajo anestesia general. RESULTADOS: Se realizó el implante exitoso con técnica de tres incisiones en los dos primeros casos y con técnica de dos incisiones en los dos últimos casos. Se corroboró el adecuado funcionamiento del dispositivo en sala, con la verificación de terapia apropiada (65 J) de la fibrilación ventricular inducida mediante estimulación a 50 Hz. No hubo complicaciones inmediatas. Un paciente presentó descargas apropiadas a los dos meses del implante. En el seguimiento, un niño desarrolló erosión de la piel a nivel de la curva del electrodo en el esternón, sin datos de infección. En quirófano se resecó la piel dañada, se retiró el barril y la seda de fijación, se realizó lavado quirúrgico y se volvió a cerrar la piel, logrando así evitar el retiro del sistema. CONCLUSIONES: El DAI-SC es una terapia alternativa al DAI endovenoso y puede ser considerado de primera elección en aquellos casos que no requieran de estimulación ventricular, incluyendo pacientes pediátricos. Pueden ocurrir complicaciones cutáneas, pero no representan una amenaza como las complicaciones venosas de los DAI convencionales.
Assuntos
Cardiologia , Desfibriladores Implantáveis , Humanos , Criança , México , Resultado do Tratamento , Cardioversão Elétrica , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologiaRESUMO
BACKGROUND: Our main objective was to present a multidisciplinary review on the epidemiology of sudden cardiac death (SCD) and the tools that could be used to identify malignant ventricular arrhythmias (VAs) and to perform risk stratification. In addition, indications and contraindications for the use of implantable cardioverter defibrillator (ICD) in general and in special populations including the elderly and patients with chronic kidney disease (CKD) are also given. METHODS: An expert group from the Inter American Society of Cardiology (IASC), through their HF Council (CIFACAH) and Electrocardiology Council (ElectroSIAC), together with the Latin American Heart Rhythm Society (LAHRS), reviewed and discussed the literature regarding the appropriate use of an ICD in people with heart failure (HF) with reduced ejection fraction (HFpEF). Indications and contraindications for the use of ICD are presented in this multidisciplinary review. RESULTS: Numerous clinical studies have demonstrated the usefulness of ICD in both primary and secondary prevention of SCD in HFpEF. There are currently precise indications and contraindications for the use of these devices. CONCLUSIONS: In some Latin American countries, a low rate of implantation is correlated with low incomes, but this is not the case for all Latin America. Determinants of the low rates of ICD implantation in many Latin American countries are still a matter of research. VA remains one of the most common causes of cardiovascular death associated with HFrEF and different tools are available for stratifying the risk of SCD in this population.
Assuntos
Cardiologia , Desfibriladores Implantáveis , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Estados Unidos/epidemiologia , Idoso , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Volume Sistólico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Disfunção Ventricular Esquerda/complicações , Desfibriladores Implantáveis/efeitos adversos , Fatores de RiscoRESUMO
SUMMARY BACKGROUND/INTRODUCTION: Heart failure patients with reduced ejection fraction are at high risk for ventricular arrhythmias and sudden cardiac death. Ivabradine, a specific inhibitor of the If current in the sinoatrial node, provides heart rate reduction in sinus rhythm and angina control in chronic coronary syndromes. OBJECTIVE: The effect of ivabradine on ventricular arrhythmias in heart failure patients with reduced ejection fraction patients has not been fully elucidated. The aim of this study was to investigate the effect of ivabradine use on life-threatening arrhythmias and long-term mortality in heart failure patients with reduced ejection fraction patients. METHODS: In this retrospective study, 1,639 patients with heart failure patients with reduced ejection fraction were included. Patients were divided into two groups: ivabradine users and nonusers. Patients presenting with ventricular tachycardia, the presence of ventricular extrasystole, and ventricular tachycardia in 24-h rhythm monitoring, appropriate implantable cardioverter-defibrillator shocks, and long-term mortality outcomes were evaluated according to ivabradine use. RESULTS: After adjustment for all possible variables, admission with ventricular tachycardia was three times higher in ivabradine nonusers (95% confidence interval 1.5-10.2). The presence of premature ventricular contractions and ventricular tachycardias in 24-h rhythm Holter monitoring was notably higher in ivabradine nonusers. According to the adjusted model for all variables, 4.1 times more appropriate implantable cardioverter-defibrillator shocks were observed in the ivabradine nonusers than the users (95%CI 1.8-9.6). Long-term mortality did not differ between these groups after adjustment for all covariates. CONCLUSION: The use of ivabradine reduced the appropriate implantable cardioverter-defibrillator discharge in heart failure patients with reduced ejection fraction patients. Ivabradine has potential in the treatment of ventricular arrhythmias in heart failure patients with reduced ejection fraction patients.
RESUMO
El uso de la resonancia magnética (RM) en las distintas áreas de la medicina se ha expandido de manera significativa y de forma diaria se solicitan numerosos estudios. El hecho de que los resonadores pueden interaccionar con algunos objetos ha llevado a que históricamente se les niegue la realización de este estudio a pacientes portadores de dispositivos cardíacos porque se entiende que existen contraindicaciones absolutas. El avance de la tecnología de los dispositivos y la creciente evidencia publicada han cambiado este concepto. Nos proponemos revisar los mecanismos por los cuales un dispositivo implantable puede interactuar con el resonador y las implicancias clínicas que esto podría tener si las hubiera. La mayoría de los pacientes portadores de dispositivos cardíacos de estimulación podrán realizarse una RM, pero para que este procedimiento sea seguro es importante conocer las características y el tipo específico de dispositivo implantado. Proponemos finalmente puntos clave y algoritmos para tener en cuenta para el manejo adecuado de estos pacientes.
The use of magnetic resonance imaging (MRI) in different areas of medicine has expanded significantly and numerous procedures are indicated daily. The fact that resonators could interact with some objects has historically led to patients with cardiac devices being denied an MRI on the understanding that they suppose an absolute contraindication. Advances in device technology and the increasing evidence have changed this concept. We intend to review the mechanisms by which an implantable device could interact with the resonator and the clinical implications that this could have if any. Most patients will be able to undergo these studies, but to determine the safety of performing an MRI it is important to know the characteristics and specific type of implanted device. Finally, we provide key points and algorithms to take into account for these patients.
O uso da ressonância magnética em diferentes áreas da medicina tem se expandido significativamente e inúmeros exames são indicados diariamente. A possibilidade de que os ressonadores interajam com alguns objetos historicamente levou os pacientes com dispositivos cardíacos a terem a ressonância magnética negada por entender que existem contraindicações absolutas. Os avanços na tecnologia de dispositivos e o aumento das evidências publicadas mudaram esse conceito. Pretendemos revisar os mecanismos pelos quais um dispositivo implantável pode interagir com o ressonador e as implicações clínicas que isso pode ter, se houver. A grande maioria dos pacientes poderá se submeter a esses estudos, mas para determinar a segurança de realizar uma ressonância magnética é importante conhecer as características e o tipo específico de dispositivo implantado. Por fim, propomos pontos e algoritmos para a gestão dos pacientes.
Assuntos
Humanos , Marca-Passo Artificial , Imageamento por Ressonância Magnética/efeitos adversos , Espectroscopia de Ressonância Magnética/efeitos adversos , Desfibriladores Implantáveis , Administração dos Cuidados ao PacienteRESUMO
SUMMARY OBJECTIVE: This study aimed to evaluate the agreement in the indication of implantable cardioverter-defibrillators in patients with Hypertrophic cardiomyopathy, as per the 2014 European Society of Cardiology and 2020 American Heart Association recommendations, and evaluate fragmented QRS as a predictor of cardiovascular outcome. METHODS: Retrospective cohort with 81 patients was evaluated between 2019 and 2021. Patients with hypertrophic cardiomyopathy ≥16 years old were included. Exclusion criteria include secondary myocardiopathy and follow-up <1 year. Kappa coefficient was used to determine the agreement. Survival and incidence curves were determined by Kaplan-Meier method. A p<0.05 was considered significant. RESULTS: The fragmented QRS was identified in 44.4% of patients. There were no differences between patients with and without fragmented QRS regarding clinical parameters, echocardiography, fibrosis, and sudden cardiac death risk. During follow-up of 4.8±3.4 years, there was no sudden cardiac death, but 20.6% patients with implantable cardioverter-defibrillator had at least one appropriate shock. Three of the seven appropriate shocks occurred in European Society of Cardiology low- to moderate-risk patients. Three shocks occurred in moderate-risk patients and four in American Heart Association high-risk patients. Overall recommendations agreement was 64% with a kappa of 0.270 (p=0.007). C-statistic showed no differences regarding the incidence of appropriate shock (p=0.644). CONCLUSION: sudden cardiac death risk stratification algorithms present discrepancies in implantable cardioverter-defibrillator indication, both with low accuracy.
RESUMO
Background: The remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) has become a common method of in-home monitoring and follow-up in high-income countries given its effectiveness, safety, convenience, and the possibility of early intervention. However, in Brazil, RM is still underutilized. Objectives: This observational study aims to demonstrate our experience of using RM in Brazil and the predictive factors of RM of CIED follow-up in Brazil. Methods: This was a prospective cohort study of patients with a CIED. Event rates are reported and clinical responses to those findings and outcomes based on the detection of RM. A logistic regression model was performed to identify predictors of more events, with P < .05 for statistical significance. Results: This study evaluated consecutive 119 patients: 30.2% with pacemakers, 42.8% with implantable cardioverter-defibrillator, 22.7% with cardiac resynchronization therapy (CRT) with defibrillator, and 3.3% with CRT with pacemaker. Events were detected in 63.9% of the cases in 29.5 ± 23 months of follow-up. The outcomes found were that 44.5% needed elective evaluation in medical treatment and 23.5% needed immediate evaluation in therapy. Logistic regression analysis showed that the groups with CRT or CRT with defibrillator (75.0%), reduced ejection fraction (76.5%), and New York Heart Association functional class ≥II (75.0%) had the highest RM event rates. Conclusions: RM proved to be effective and safe in the follow-up of patients with CIEDs in Brazil, allowing early interventions and facilitating therapeutic management.
RESUMO
BACKGROUND/OBJECTIVES: Implantable cardioverter defibrillators are used to prevent sudden cardiac death. The subcutaneous implantable cardioverter-defibrillator was newly developed to overcome the limitations of the conventional implantable cardioverter defibrillator-transvenous device. The subcutaneous implantable cardioverter defibrillator is indicated for young patients with heart disease, congenital heart defects, and poor venous access, who have an indication for implantable cardioverter defibrillator without the need for anti-bradycardic stimulation. We aimed to compare the efficacy and complications of subcutaneous with transvenous implantable cardioverter- defibrillator devices. METHODOLOGY: A systematic review was conducted using different databases. The inclusion criteria were observational and clinical randomized trials with no language limits and no publication date limit that compared subcutaneous with transvenous implantable cardioverter-defibrillators. The selected patients were aged > 18 years with complex ventricular arrhythmia. RESULTS: Five studies involving 2111 patients who underwent implantable cardioverter defibrillator implantation were included. The most frequent complication in the subcutaneous device group was infection, followed by hematoma formation and electrode migration. For the transvenous device, the most frequent complications were electrode migration and infection. Regarding efficacy, the total rates of appropriate shocks were 9.04% and 20.47% in the subcutaneous and transvenous device groups, respectively, whereas inappropriate shocks to the subcutaneous and transvenous device groups were 11,3% and 10,7%, respectively. CONCLUSION: When compared to the transvenous device, the subcutaneous device had lower complication rates owing to lead migration and less inappropriate shocks due to supraventricular tachycardia; nevertheless, infection rates and improper shocks due to T wave oversensing were comparable for both devices CRD42021251569.
Assuntos
Desfibriladores Implantáveis , Taquicardia Supraventricular , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Humanos , Resultado do TratamentoRESUMO
Resumen: Reportamos el caso de un hombre de 67 años, con múltiples factores de riesgo cardiovascular, quien en el año 2015 presentó muerte súbita por fibrilación ventricular sin lesiones coronarias significativas, tras lo cual se implantó un desfibrilador automático. En el año 2019 presentó un nuevo episodio de fibrilación ventricular en relación con síndrome coronario agudo con supradesnivel del ST localizado en pared anterior, registrado y adecuadamente resuelto por el dispositivo. Se demostró una oclusión aterotrombótica en la porción proximal de la arteria descendente anterior. Fue precoz y exitosamente manejado con angioplastía coronaria percutánea e implante de stent fármaco activo, guiado por tomografía por coherencia óptica intracoronaria. A las 48 horas post angioplastía, presentó episodio de taquicardia ventricular polimorfa reconocido y tratado por el cardiodesfibrilador, sin consecuencias. Electivamente se efectuó angioplastía e implante de stent metálico en arteria coronaria derecha distal, con buen resultado angiográfico. La posterior evolución del paciente fue satisfactoria, sin manifestaciones de insuficiencia cardíaca, angina ni arritmias.
Abstract: A 67-year-old man, with multiple cardiovascular risk factors who in 2015 presented sudden death due to ventricular fibrillation without significant coronary lesions, after which an implantable automatic defibrillator (ICD) was implanted. In 2019, he presented a new episode of ventricular fibrillation adequately resolved by the device, in relation to an acute coronary syndrome with ST elevation in the anterior wall of the left ventricle, due to atherothrombotic occlusion in the proximal portion of the anterior descending artery. He was early and successfully managed with percutaneous coronary angioplasty by the insertion of a drug eluting stent, implanted guided by intracoronary optical coherence tomography. Forty eight hours later, he presented an episode polymorphic ventricular tachycardia recognized and treated by the ICD. Angioplasty with a bare metal stent implantation were performed in the distal right coronary artery, with good angiographic results. The subsequent course was satisfactory, with no manifestations of heart failure, angina or arrhythmias.
Assuntos
Humanos , Masculino , Idoso , Fibrilação Ventricular/complicações , Morte Súbita Cardíaca , Isquemia Miocárdica/complicações , Desfibriladores Implantáveis , Fibrilação Ventricular/terapia , Isquemia Miocárdica/terapia , Angioplastia , Eletrocardiografia , Stents FarmacológicosRESUMO
INTRODUCTION: Ventricular arrhythmias (VAs) are a major cause of morbidity and mortality in patients with heart disease. Recent studies evaluated the effect of renal denervation (RDN) on the occurrence of VAs. We conducted a systematic review and meta-analysis to determine the efficacy and safety of this procedure. METHODS AND RESULTS: A systematic search of the literature was performed to identify studies that evaluated the use of RDN for the management of VAs. Primary outcomes were reduction in the number of VAs and implantable cardioverter-defibrillator (ICD) therapies. Secondary outcomes were changes in blood pressure and renal function. Ten studies (152 patients) were included in the meta-analysis. RDN was associated with a reduction in the number of VAs, antitachycardia pacing, ICD shocks, and overall ICD therapies of 3.53 events/patient/month (95% confidence interval [CI] = -5.48 to -1.57), 2.86 events/patient/month (95% CI = -4.09 to -1.63), 2.04 events/patient/month (95% CI = -2.12 to -1.97), and 2.68 events/patient/month (95% CI = -3.58 to -1.78), respectively. Periprocedural adverse events occurred in 1.23% of patients and no significant changes were seen in blood pressure or renal function. CONCLUSIONS: In patients with refractory VAs, RDN was associated with a reduction in the number of VAs and ICD therapies, and was shown to be a safe procedure.
Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Denervação , Humanos , Rim/fisiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do TratamentoRESUMO
Axillary vein puncture guided by ultrasound (US-Ax) versus cephalic vein dissection in pacemaker and defibrillator implant: a multicenter randomized clinical trial is a recently published study in which 88 patients were randomized in a 1:1 fashion to one of the two methods. Even being performed by operators with not previous ultrasound-guided axillary vein puncture experience, this group presented a higher success rate, lower procedural time and comparable complication incidence.
Lay abstract Recently a study evaluating two different approaches to cardiac devices implant was published. In the study, 88 patients were assigned to one of two methods for this procedure. The operators had no previous experience in one of the methods, but it demonstrated a higher success rate, took less time and had the same number of complications as the method the doctors had experience in. This paper evaluated the study and discusses what changes might take place in clinics as a result of these findings.
Assuntos
Veia Axilar , Desfibriladores Implantáveis , Veia Axilar/diagnóstico por imagem , Veia Axilar/cirurgia , Dissecação , Humanos , Flebografia , Punções , Ultrassonografia de IntervençãoRESUMO
Background: Permanent pacemaker placement (PPM) is associated with morbidity following cardiac surgery. This study identified associations between PPM placement and 5-year outcomes for patients that require PPM following valvular surgery. Methods: All patients who underwent valvular surgery at our medical center from 2011 to 2018 were considered for analysis. Multivariable analysis identified associations between PPM placement, mortality, and readmissions. Primary outcomes were operative complications and mortality. Secondary outcomes included 5-year survival and readmission. Results: A total of 175 (4.86%) of 3602 valvular surgery patients required postoperative PPM. The PPM cohort had significantly worse baseline comorbidities, including greater Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores (3.8 vs 2.4 P < .0001). The PPM cohort had greater rates of blood product transfusion, prolonged ventilation, and new-onset atrial fibrillation. PPM placement was significantly associated with third-degree heart block (5.26; 95% confidence interval [95% CI], 1.00-27.53; P = .0496), ventricular fibrillation/tachycardia (3.90; 95% CI, 1.59-9.59; P = .01), and atrial fibrillation/flutter (1.53; 95% CI, 1.05-2.24; P = .03). On Kaplan-Meier estimates, 5-year survival (68.8% vs 83.1%; P = 01) was significantly reduced in the PPM cohort. Five-year all-cause readmission (60.4% vs 50.04%; P = .01) and heart failure readmission (35.5% vs 20.1%; P < .000) occurred more frequently in the PPM cohort. On multivariable Cox regression analysis, PPM placement (hazard ratio, 1.12; 95% CI, 0.84-1.50; P = .444) was not an independent predictor of mortality. On competing risk analysis, PPM (hazard ratio, 1.33; 95% CI, 0.99-1.80; P = .062) was not a predictor of hospital readmission. Conclusions: Valvular surgery patients who required postoperative PPM had elevated baseline operative risk. However, PPM implantation was not associated with mortality or readmission.
RESUMO
Chagas cardiomyopathy is a parasitic infection caused by Trypanosoma cruzi. Structural and functional abnormalities are the result of direct myocardial damage by the parasite, immunological reactions, dysautonomia, and microvascular alterations. Chronic Chagas cardiomyopathy (CCC) is the most serious and important manifestation of the disease, affecting up to 30% of patients in the chronic phase. It results in heart failure, arrhythmias, thromboembolism, and sudden cardiac death. As in other cardiomyopathies, scar-related reentry frequently results in ventricular tachycardia (VT). The scars typically are located in the inferior and lateral aspects of the left ventricle close to the mitral annulus extending from endocardium to epicardium. The scars may be more prominent in the epicardium than in the endocardium, so epicardial mapping and ablation frequently are required. Identification of late potentials during sinus rhythm and mid-diastolic potentials during hemodynamically tolerated VT are the main targets for ablation. High-density mapping during sinus rhythm can identify late isochronal regions that are then targeted for ablation. Preablation cardiac magnetic resonance imaging with late enhancement can identify potentials areas of arrhythmogenesis. Therapeutic alternatives for VT management include antiarrhythmic drugs and modulation of the cardiac autonomic nervous system.
RESUMO
Abstract Chagas disease (CD), with approximately 10,000 deaths annually, has become a worldwide health problem. Approximately 35% of cases may show cardiac manifestations such as arrhythmias and/or conduction disorders, heart failure, thromboembolic accidents, and sudden death. The Amazon region has long been considered a non-endemic area for CD; however, in the last decades, with an increase in the number of acute and chronic cases, disease evolution has received greater attention. Here, we report the successful implementation of a cardioverter-defibrillator for the prevention of sudden death in a patient with autochthonous Chagas cardiomyopathy in the Brazilian Amazon.
Assuntos
Humanos , Cardiomiopatia Chagásica/complicações , Desfibriladores Implantáveis , Brasil , Morte Súbita Cardíaca/prevenção & controle , EletrocardiografiaRESUMO
Abstract Introduction: complications due to cardiac implantable electronic devices have been sparsely studied despite the increased number and complexity of these procedures in a population with multiple comorbidities. Objective: to determine the complication rate and associated risk factors at a reference center in Colombia. Methods: retrospective cohort study, which included patients who had a cardiac electronic device implanted between 2012 and 2015. Clinical records were reviewed to determine if patients developed complications during the year after the procedure, and, if so, which type and which clinical variables could be related to. Results: a total of 897 patients were included, 620 with pacemaker implants and 277 with other devices. The average age was 71.4 years, 63.9% were men, almost all the patients had a chronic disease, and 70% were de novo implants. The global complication rate was 10.9%; Lead displacement (3.6%) and pocket hematoma (3.3%) were the most frequent complications; 7.5% were major complications, and 73.5% occurred in the first month after procedure. The hospitalization rate associated with complications was 9.5%, and the median hospital stay was seven days, with 66.3% of these patients requiring new interventions. The mortality rate was 0.2% Conclusions: complications associated with cardiac implantable electronic devices occur red mainly in the first trimester after the initial intervention, were more frequent in patients under 80 years old, increased according to device complexity, and were not related to with the studied comorbidities.
Resumen Introducción: las complicaciones secundarias al implante de dispositivos cardiacos electrónicos han sido poco estudiadas a pesar del aumento en número y complejidad de estos procedimientos en población con múltiples comorbilidades. Objetivo: determinar la tasa de complicaciones del implante de dispositivos y los factores de riesgo asociados, en un centro de referencia en Colombia. Métodos: estudio de cohorte retrospectiva, que incluyó pacientes a quienes se les implantó dispositivo electrónico cardiaco entre 2012 y 2015. Se revisó la historia clínica para determinar si durante un año posterior al procedimiento, presentaron complicaciones, de qué tipo y con qué variables clínicas podría asociarse. Resultados: se incluyeron 897 pacientes, 620 con implante de marcapaso y 277 otros dispositivos. La edad promedio fue 71.4 años, 63.9% hombres, con múltiples enfermedades crónicas, 70% fueron implantes de novo. Se observó una tasa de complicaciones del 10.9%, la cual varía de acuerdo con el tipo de dispositivo. El desalojo del electrodo (3.6%) y el hematoma del bolsillo (3.3%) fueron las complicaciones más frecuentes, 7.5% fueron complicaciones mayores y 73.5% se presentaron en el primer mes postoperatorio. La tasa de hospitalización asociada a complicación fue 9.5%, mediana de estancia de 7 días, con un 66.3% de los pacientes en requerimiento de reintervención. La tasa de mortalidad fue del 0.2%. Conclusiones: las complicaciones asociadas al implante de dispositivos eléctricos cardiacos se presentaron principalmente en el primer trimestre, fueron más frecuentes en menores de 80 años, aumentaron con la complejidad del dispositivo y no se relacionaron con las comorbilidades estudiadas.
Assuntos
Humanos , Masculino , Idoso , Desfibriladores , Terapia de Ressincronização Cardíaca , Marca-Passo Artificial , Fatores de Risco de Doenças CardíacasRESUMO
OBJECTIVES: The purpose of this study was to investigate the effect of sacubitril/valsartan therapy on sudden cardiac death (SCD) according to the use of and eligibility for an implantable cardioverter-defibrillator (ICD), stratified by heart failure cause. BACKGROUND: SCD still accounts for a significant proportion of overall mortality in heart failure with reduced ejection fraction (HFrEF). METHODS: Patients enrolled in the PARADIGM-HF (Prospective Comparison of ARNI with an ACE-Inhibitor to Determine Impact on Global Mortality and Morbidity in Heart Failure) trial (n = 8,399) were evaluated to assess patterns of ICD implantation and eligibility according to clinical guidelines. The impact of ICD (adjusted for propensity of ICD implantation) and sacubitril/valsartan therapy on SCD was evaluated by using cause-specific Cox models and competing risk analysis. RESULTS: At baseline, of the 7,145 patients (85%) eligible for ICD implantation, only 1,243 (15%) had an ICD. Use of ICD varied by region with the highest rates in North America (56%) and lowest in Asia-Pacific (1.7%). In a propensity score-adjusted analysis, use of an ICD was associated with a 56% lower risk of SCD in ICD-eligible patients, in both patients with ischemic (p < 0.001) and nonischemic cardiomyopathy (p = 0.02). Sacubitril/valsartan reduced SCD risk in patients with an ICD (hazard ratio [HR]: 0.49; 95% confidence interval [CI]: 0.25 to 0.99) and in those who were eligible for but did not receive an ICD (HR: 0.81; 95% CI: 0.67 to 0.98). This effect was particularly evident in nonischemic cardiomyopathy (p < 0.05), although interaction with the cause of HF was not significant (p = 0.11 in subjects using an ICD and p = 0.25 in eligible nonusers). CONCLUSIONS: Use of an ICD was associated with lower rates of SCD, regardless of HF cause but was underused in most regions of the world in the PARADIGM-HF study. Sacubitril/valsartan reduced SCD risk regardless of use of an ICD or eligibility, particularly in ICD users and nonischemic cardiomyopathy.