RESUMO
Objective: This study evaluated different methods of calcium hydroxide (CH) removal from root canals with simulated internal resorptions using microcomputed tomography (micro-CT). Material and Methods: Sixty acrylic resin blocks with simulated root canals and internal resorptions were prepared using a Reciproc R25 file and then filled with CH. The blocks were divided into five test groups (n=12) according to the method used for CH removal: hand files (HF), Easy Clean (EC), passive ultrasonic irrigation (PUI), XP-Endo Finisher (XP), XP-Endo Finisher + PUI (XP+PUI). The blocks were scanned using a SkyScan 1172 scanner before and after CH removal to measure the volume and percentage of CH removal. The OriginPro 2017 software was used for statistical analyses. The level of significance was set at p<0.05 for all tests. Results: No method under study removed all CH. All methods had similar results in the cervical third (P>0.05). The percentage of CH removal was significantly greater in the area of internal resorption and along the total length of the canal in the XP+PUI group (P<0.05). The best results of CH removal were found in the apical third of roots in the XP+PUI and PUI groups (P>0.05). Conclusion: No method removed all CH from the root canals, but the combined XP+PUI method removed more CH than the other methods, especially from the area of the internal resorption(AU)
Objetivo: Este estudo avaliou diferentes métodos de remoção de hidróxido de cálcio (CH) de canais radiculares com reabsorções internas simuladas por meio de microtomografia computadorizada (micro-CT). Material e Métodos: Sessenta blocos de resina acrílica com canais radiculares simulados e reabsorções internas foram preparados com lima Reciproc R25 e posteriormente preenchidos com CH. Os blocos foram divididos em cinco grupos de teste (n=12) de acordo com o método utilizado para remoção de CH: limas manuais (HF), Easy Clean (EC), irrigação ultrassônica passiva (PUI), XP-Endo Finisher (XP), XP -Endo Finalizador + PUI (XP + PUI). Os blocos foram escaneados usando um scanner SkyScan 1172 antes e depois da remoção do CH para medir o volume e a porcentagem de remoção do CH. O software OriginPro 2017 foi utilizado para análises estatísticas. O nível de significância foi estabelecido em p<0,05 para todos os testes. Resultados: Nenhum método em estudo removeu todos o CH. Todos os métodos tiveram resultados semelhantes no terço cervical (P>0,05). A porcentagem de remoção de CH foi significativamente maior na área de reabsorção interna e ao longo do comprimento total do canal no grupo XP+PUI (P<0,05). Os melhores resultados de remoção de CH foram encontrados no terço apical das raízes nos grupos XP+PUI e PUI (P>0,05). Conclusão: Nenhum método removeu todo o CH dos canais radiculares, mas o método combinado XP+PUI removeu significativamente mais CH do que os outros métodos, especialmente da área de reabsorção interna (AU)
Assuntos
Reabsorção de Dente , Hidróxido de Cálcio , Instrumentos Odontológicos , Cavidade Pulpar , Microtomografia por Raio-XRESUMO
Aim: The purpose of this study was to evaluate the efficacy to determine the root canal length, in vitro,of both the electronic apex locator (M2) and the autostop (AS - M3) functions of the Endus Duo Gnatus endodontic motor (Gnatus, São Paulo, SP, Brazil). Methods: Thirty extracted human single-rooted premolars had their root canal lengths (TLs) up to the apical foramen determined using the Endus Duo Gnatus in two ways: (1) In the stainless steel (SS) control group, the measurement was obtained using a stainless steel hand instrument with the electronic locator mode (M2 function) connected to a stainless-steel hand instrument (K-file #15). In the NiTi rotary instrument (NiTi RI) intervention group, the measurement was obtained during the instrumentation (M3 function) of the root canals with a nickel-titanium rotary instrument (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, USA), size 25/.06. The NiTi manually used instrument (NiTi MUI) Intervention group performed the measurement in locator mode using a Hyflex instrument, placed to true length manually. Statistical analysis was performed using ANOVA followed by the Tukey post-hoc test with a significance level of p < 0.05. Results: The true mean length and standard deviation (SD) of the standardized root canals were 18.40 ± 2.14mm, while the mean lengths and standard deviations (SD) were 18.29 ± 1.89mm, 18.22 ± 1.85mm, and 17.24 ± 2.09mm for the SS, NiTi RI, and NiTi MUI groups, respectively. However, data from the NiTi MUI Intervention group indicated shorter root canal lengths when compared to the SS control group and the NiTi RI Intervention group values, and were significantly shorter than the true canal length (p < 0.001). Conclusions:The use of the motor in NiTi RI Intervention group showed acceptable results. However, the NiTi MUI Intervention group resulted in unacceptable short measurements.
Objetivo: O objetivo deste estudo foi avaliar a eficácia na determinação do comprimento do canal radicular, in vitro, das funções localizador eletrônico foraminal (M2) e auto-parada durante a instrumentação (M3) do motor endodôntico Endus Duo Gnatus ( Gnatus, São Paulo, SP, Brasil). Métodos: Trinta pré-molares humanos uniradiculares extraídos tiveram seus comprimentos de canais radiculares (CRTs) até o forame apical determinados usando o Endus Duo Gnatus de duas maneiras: (1) No grupo controle de aço inoxidável (SS), a medida foi obtida usando um instrumento manual de aço inoxidável com modo de localização eletrônica foraminal (função M2) conectado a um instrumento manual de aço inoxidável (lima tipo K #15). No grupo intervenção instrumento rotatório NiTi (NiTi RI), a medida foi obtida durante a instrumentação (função M3) dos canais radiculares com instrumento rotatório de níquel-titânio (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, EUA), tamanho 25/.06. O grupo de intervenção NiTi instrumento usado manualmente (NiTi MUI) realizou a medição no modo localizador foraminal usando um instrumento Hyflex, colocado manualmente no comprimento real do dente. A análise estatística foi realizada por meio de ANOVA seguida do teste post-hoc de Tukey com nível de significância de p < 0,05. Resultados: Os comprimentos reais médios dos dentes e desvios-padrão (DP) dos canais radiculares padronizados foram 18,40 ± 2,14 mm, enquanto os comprimentos médios e desvios- padrão (DP) foram 18,29 ± 1,89 mm, 18,22 ± 1,85 mm e 17,24 ± 2,09 mm para os grupos SS, NiTi RI e NiTi MUI, respectivamente. No entanto, os dados do grupo de intervenção NiTi MUI indicaram comprimentos de canais radiculares mais curtos quando comparados aos valores do grupo controle SS e do grupo de intervenção NiTi RI, e foram significativamente mais curtos que o comprimento real do canal (p < 0,001). Conclusões: A utilização do motor no grupo Intervenção NiTi RI apresentou resultados aceitáveis. No entanto, o grupo de intervenção NiTi MUI resultou em medições curtas inaceitáveis.