J. optom. (Internet) ; 17(3): [100514], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231876

RESUMO

Purpose: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. Methods: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. Results: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. Conclusions: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Ceratocone , Óculos , Lentes de Contato , Visão Binocular , Testes Visuais , Colômbia , México , Oftalmologia , Estudos Prospectivos
2.
Cureus ; 16(6): e62093, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989385

RESUMO

BACKGROUND: Previous studies have suggested that light rays may interact with contact lenses, potentially affecting their transmittance. AIM: This study aimed to investigate the effects of visible and ultraviolet (UV)-A light sources on the transmittance of some commercially available daily, weekly, and monthly contact lenses. METHODS: Nine commercially available soft contact lenses were irradiated with a solar simulator, light-emitting diode (LED) source, laser source, and UV-A source. The average transmittance of the tested lenses before and after irradiation in the UV, visible, and infrared light wavelength ranges was determined using an Agilent UV-visible spectrophotometer, model 8453. RESULTS: The results showed a partial or complete block of UV transmission at the UV-B region (300 nm) and the UV-A region (355 nm) by the Bio true daily contact lens, as well as the Acuvue Oasys, Avaira, and Biomedics 55 weekly lenses. At the visible region (555 nm), irradiation of the contact lenses by different light sources resulted in reduced light transmittance. At the infrared region (900 nm), the weekly and monthly contact lenses partially blocked infrared transmission, while the daily lenses showed either increased or decreased infrared transmission. CONCLUSIONS: Solar and artificial lighting, as well as high-powered lasers, constitute a major concern on the contact lenses' light transmission and optical properties. It is essential to develop soft contact lenses that have photoprotective properties while maintaining visible light transmittance.

3.
Am J Ophthalmol Case Rep ; 36: 102092, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39036656

RESUMO

Purpose: To report a case of a 67-year-old male who was successfully managed over a 7-year period for descemetocele secondary to ocular graft versus host disease (oGVHD) using Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) treatment. Observations: We previously reported on a patient managed with a PROSE device for severe dry eyes secondary to oGVHD, who subsequently developed a central corneal descemetocele. The patient was deemed a poor surgical candidate due to limbal stem cell deficiency secondary to oGVHD. Therefore, we elected to closely monitor the descemetocele as the patient continued PROSE therapy. The patient's descemetocele has been managed successfully without perforation throughout a 7-year follow-up period with corrected distance visual acuity remaining stable at 20/50 in the affected eye. Conclusions and importance: Descemetoceles are an uncommon complication of ocular graft versus host disease. This is the longest published report of a corneal descemetocele managed with PROSE. Our report suggests that in appropriate patients who are at high-risk for post-surgical complications, PROSE in conjunction with other medical management should be considered as an alternative to corneal transplantation.

4.
J Clin Med ; 13(13)2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38999403

RESUMO

Scleral lenses (SLs) are large-diameter rigid contact lenses that are a mainstay treatment for eyes with corneal irregularities. In recent years, there has been increased interest in the role of managing dry eye disease (DED) with SLs, as many patients with DED have reported symptomatic relief with SL wear. The role of SLs for DED management when there are associated corneal irregularities is supported by individual case reports and studies. This has prompted practitioners to begin advocating using SLs in DED cases, even in the absence of associated corneal irregularities and other ocular surface diseases (OSDs). There have also been discussions on potentially placing SLs earlier in the treatment hierarchy of DED, where it currently sits at a more advanced level of intervention (Step 3) in the TFOS DEWS II Report. This review will present the currently available, albeit sparse, evidence that supports and suggests this practice, as well as ancillary evidence supporting the purported benefits of SL wear in DED. The advantages of SL wear, such as corneal healing, absence of tear evaporation and contact lens dehydration, and improved visual acuity with associated increased wear comfort, and how this will benefit DED patients will be explored. Conversely, the challenges associated with fitting SLs in DED patients, including increased midday fogging, poor wettability, and subjective patient satisfaction, will also be presented, as well as a discussion on the key considerations for SL fitting in this population. Overall, while more research is needed to support the use of SLs in DED patients without associated corneal irregularities and other forms of OSD, the use of these lenses may prove to have a potentially wider role given their reported ancillary benefits in these populations.

5.
Cont Lens Anterior Eye ; : 102249, 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839478

RESUMO

PURPOSE: Contact lenses can be contaminated with various microorganisms, including pathogenic yeasts of the genus Candida, which are known for their ability to adhere to abiotic surfaces, including plastic materials used for various medical purposes. Microbial contamination of the lenses can lead to infection of the wearer's eyes. The purpose of this study was to simulate the contamination of contact lenses with C. albicans and C. parapsilosis, analyze the interaction of the microorganisms with the lens material, and optimize the protocol for PCR-based analysis of the microbial agents responsible for lens contamination. METHODS: Hilafilcon lenses were exposed to C. albicans and C. parapsilosis cultures, washed, and examined for their ability to further spread the contamination. Scanning electron microscopy was used to analyze the attachment of yeast cells to the lenses. Infrared spectroscopy was used to examine the potential changes in the lens material due to Candida contamination. The protocol for DNA isolation from contaminated lenses was established to enable PCR analysis of microbes attached to the lenses. RESULTS: Hilafilcon lenses contaminated with Candida were able to spread the contamination even after washing with saline or with a commercial cleaning solution. In the present experimental settings, the yeasts did not grow into the lenses but began to form biofilms on the surface. However, the ability of the lenses to retain water was altered. The PCR-based protocol could be used to help identify the type of contamination of contact lenses. CONCLUSION: Once contaminated with Candida albicans or Candida parapsilosis, Hilafilcon contact lenses are difficult to clean. Yeasts began to form biofilms on lens surfaces.

6.
J Fr Ophtalmol ; 47(8): 104235, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38905773

RESUMO

PURPOSE: To present a case series of patients with corneal scars who were successfully fitted with mini scleral contact lenses (mSCL). METHODS: Case series study. RESULTS: Six eyes of six patients with corneal scars were fitted with mSCLs. All scars were situated in the visual axis within the scotopic pupillary zone. The sizes of the scars varied, with the smallest being confined to a central corneal area (case 5) and the largest covering the entire visual axis (case 2). In addition to compromising corneal transparency, these scars also induced significant corneal irregularities, especially in cases 1, 3, and 4. The average corrected distance visual acuity (CDVA) with spectacles was 20/80, with a range of 20/200 to 20/40. With the use of mSCLs, CDVA improved to an average of 20/25, ranging from 20/40 to 20/16. The mean visual acuity improvement observed was five optotype lines, with a range of 3 to 7 lines. CONCLUSION: Corneas with scars often exhibit increased higher-order aberrations (HOA), and affected patients not only experience reduced vision but also suffer from seriously reduced optical quality and optical phenomena such as photophobia. Utilizing mSCLs in such individuals can significantly enhance visual acuity and improve optical side effects resulting from corneal opacity and irregularity.

7.
Life (Basel) ; 14(6)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38929636

RESUMO

Ocular surface staining for assessing corneal and conjunctival epithelium integrity is typically conducted using fluorescein, lissamine green, or rose Bengal dyes. Recently, a novel vital dye, REmark®, based on riboflavin, has been proposed for ocular surface examination. In the management of corneal and ocular surface diseases (OSD), the use of contact lenses is integral to therapeutic strategies. This study explores the compatibility of REmark® with four different types of disposable or bi-weekly soft contact lenses. Morphological variations observed under stereomicroscopy and ultraviolet (UV) ray transmittance in the visible spectrum (VIS) were evaluated at 2 and 4 h post-immersion of the contact lenses in both the original fluid and the new dye. The findings indicate no significant differences between the group treated with the original liquid and those immersed in REmark®, except for a yellow hue observed in the latter group, which dissipates after 8 h in physiological solution. This study highlights the potential of utilizing the new vital dye for ophthalmologic examinations even in the presence of applied soft contact lenses, offering a promising avenue for improved diagnostic practices and patient comfort.

8.
Molecules ; 29(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38893485

RESUMO

The following review focuses on the manufacturing and parameterizing of ocular drug delivery systems (DDS) using polymeric materials to create soft contact lenses. It discusses the types of drugs embedded into contact lenses, the various polymeric materials used in their production, methods for assessing the mechanical properties of polymers, and techniques for studying drug release kinetics. The article also explores strategies for investigating the stability of active substances released from contact lenses. It specifically emphasizes the production of soft contact lenses modified with Cyclosporine A (CyA) for the topical treatment of specific ocular conditions. The review pays attention to methods for monitoring the stability of Cyclosporine A within the discussed DDS, as well as investigating the influence of polymer matrix type on the stability and release of CyA.


Assuntos
Ciclosporina , Liberação Controlada de Fármacos , Ciclosporina/química , Humanos , Cinética , Sistemas de Liberação de Medicamentos , Lentes de Contato Hidrofílicas , Estabilidade de Medicamentos , Polímeros/química
9.
Sensors (Basel) ; 24(11)2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38894283

RESUMO

Permanent engravings on contact lenses provide information about the manufacturing process and lens positioning when they are placed on the eye. The inspection of their morphological characteristics is important, since they can affect the user's comfort and deposit adhesion. Therefore, an inverted wavefront holoscope (a lensless microscope based on Gabor's principle of in-line digital holography) is explored for the characterization of the permanent marks of soft contact lenses. The device, based on an in-line transmission configuration, uses a partially coherent laser source to illuminate the soft contact lens placed in a cuvette filled with a saline solution for lens preservation. Holograms were recorded on a digital sensor and reconstructed by back propagation to the image plane based on the angular spectrum method. In addition, a phase-retrieval algorithm was used to enhance the quality of the recovered images. The instrument was experimentally validated through a calibration process in terms of spatial resolution and thickness estimation, showing values that perfectly agree with those that were theoretically expected. Finally, phase maps of different engravings for three commercial soft contact lenses were successfully reconstructed, validating the inverted wavefront holoscope as a potential instrument for the characterization of the permanent marks of soft contact lenses. To improve the final image quality of reconstructions, the geometry of lenses should be considered to avoid induced aberration effects.

10.
Surv Ophthalmol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710236

RESUMO

Advancements in diagnostic methods and surgical techniques for keratoconus (KC) have increased non-invasive treatment options. Successful surgical planning for KC involves a combination of clinical science, empirical evidence, and surgical expertise. Assessment of disease progression is crucial, and halting the progression should be the focus if it is progressive. While surgeons used to rely on experience alone to decide the surgical method, comparing the network of primary factors, such as visual acuity, across studies can help them choose the most appropriate treatments for each patient and achieve optimal outcomes. Meticulous tabulation methods facilitate interpretation, highlighting the importance of selecting the correct surgical and rehabilitation approach based on each patient's condition and stage of the disease. We detail the outcomes of a comprehensive network meta-analysis comparing the effectiveness of various combined therapeutic refractive treatments for KC at identical stages of the disease, spanning 4 distinct follow-up intervals. Additionally, the comprehensive analysis suggests that for corneas with optimal best corrected visual acuity (BCVA) preoperatively (classified as regular), combining phakic intraocular lenses with intracorneal ring segments (ICRS) and corneal cross-linking (CXL) could offer the best therapeutic approach provided the disease stage does not exceed stage 3. For irregular corneas, although initial follow-ups show a significant difference in BCVA with surface ablation, longer-term follow-ups recommend combining surface ablation with ICRS and CXL, especially at higher stages.

11.
Ophthalmic Physiol Opt ; 44(5): 884-893, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38778634

RESUMO

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.


Assuntos
Lentes de Contato Hidrofílicas , Sensibilidades de Contraste , Topografia da Córnea , Estudos Cross-Over , Ceratocone , Acuidade Visual , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Masculino , Feminino , Estudos Prospectivos , Adulto , Acuidade Visual/fisiologia , Adulto Jovem , Sensibilidades de Contraste/fisiologia , Topografia da Córnea/métodos , Pessoa de Meia-Idade , Desenho de Equipamento , Refração Ocular/fisiologia
12.
Ophthalmic Physiol Opt ; 44(5): 876-883, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38712751

RESUMO

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.


Assuntos
Lentes de Contato Hidrofílicas , Equipamentos Descartáveis , Síndromes do Olho Seco , Lágrimas , Humanos , Masculino , Feminino , Lágrimas/fisiologia , Lágrimas/metabolismo , Adulto Jovem , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/diagnóstico , Adulto , Erros de Refração/terapia , Erros de Refração/fisiopatologia , Silicones , Adolescente , Inquéritos e Questionários , Doenças Palpebrais/fisiopatologia , Doenças Palpebrais/terapia , Concentração Osmolar
13.
Sci Rep ; 14(1): 11727, 2024 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778161

RESUMO

The tear fluid is a readily accessible, potential source for biomarkers of disease and could be used to monitor the ocular response to contact lens (CL) wear or ophthalmic pathologies treated by therapeutic CLs. However, the tear fluid remains largely unexplored as a biomarker source for RNA-based molecular analyses. Using a rabbit model, this study sought to determine whether RNA could be collected from commercial CLs and whether the duration of CL wear would impact RNA recovery. The results were referenced to standardized strips of filtered paper (e.g., Shirmer Strips) placed in the inferior fornix. By performing total RNA isolation, precipitation, and amplification with commercial kits and RT-PCR methods, CLs were found to have no significant differences in RNA concentration and purity compared to Schirmer Strips. The study also identified genes that could be used to normalize RNA levels between tear samples. Of the potential control genes or housekeeping genes, GAPDH was the most stable. This study, which to our knowledge has never been done before, provides a methodology for the detection of RNA and gene expression changes from tear fluid that could be used to monitor or study eye diseases.


Assuntos
Lentes de Contato , RNA , Lágrimas , Lágrimas/metabolismo , Animais , Coelhos , RNA/isolamento & purificação , RNA/genética , RNA/análise
14.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742501

RESUMO

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Assuntos
Lentes de Contato , Ceratocone , Esclera , Acuidade Visual , Humanos , Ceratocone/cirurgia , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/terapia , Feminino , Masculino , Adulto , Esclera/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/instrumentação , Resultado do Tratamento , Topografia da Córnea , Próteses e Implantes , Adulto Jovem , Ajuste de Prótese/métodos , Adolescente , Substância Própria/cirurgia
15.
J Eye Mov Res ; 17(1)2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818405

RESUMO

Many video-based eye trackers rely on detecting and tracking ocular features, a task that can be negatively affected by a number of individual or environmental factors. In this context, the aim of this study was to practically evaluate how the use of a scleral contact lens with two integrated nearinfrared lasers (denoted CLP) could improve the tracking robustness in difficult lighting conditions, particularly outdoor ones. We assessed the ability of the CLP (on a model eye) to detect the lasers and to deduce a gaze position with an accuracy better than 1° under four lighting conditions (1 lx, 250 lx, 50 klux and alternating 1lx /250 lx) on an artificial eye. These results were compared to the ability of a commercial eye tracker (Pupil Core) to detect the pupil on human eyes with a confidence score equal to or greater than 0.9. CLP provided good results in all conditions (tracking accuracy and detection rates). In comparison, the Pupil Core performed well in all indoor conditions (99% detection) but failed in outdoor conditions (9.85% detection). In conclusion, the CLP presents strong potential to improve the reliability of video-based eyetrackers in outdoor conditions by providing easy trackable feature.

16.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(6): 237-247, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38588998

RESUMO

This 32-centre multicentre study addresses the lack of knowledge about the prevalence and significance of microbial keratitis (MK) associated with contact lens (CL) wear in Spain. A total of 304 cases recruited from 32 hospitals were studied and showed that infectious keratitis associated with contact lens wear mainly affects young women during the summer months. In this study, soft lenses with monthly replacement and single solution cleaning were most commonly used, purchased and fitted in opticians' shops. Common risk factors were identified among users, such as topping off solutions, prolonging the life of lenses, and frequently sleeping, swimming and showering with lenses. Overnight lens wear was significantly associated with a higher incidence of corneal opacities, and the presence of Pseudomonas aeruginosa in bacterial cultures was associated with more severe sequelae and a greater need for corneal transplantation. Although most cases were benign, the time taken to heal was long, which poses a problem for working patients. This study provides valuable epidemiological, microbiological and risk factor information and estimates the incidence of CL related MK in Spain to be approximately 1 case per 30,000 inhabitants per year.


Assuntos
Lentes de Contato , Ceratite , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Lentes de Contato/efeitos adversos , Lentes de Contato/microbiologia , Infecções Oculares Bacterianas/epidemiologia , Infecções Oculares Bacterianas/etiologia , Infecções Oculares Bacterianas/microbiologia , Incidência , Ceratite/microbiologia , Ceratite/epidemiologia , Ceratite/etiologia , Prevalência , Fatores de Risco , Espanha/epidemiologia
17.
Adv Mater ; 36(27): e2313848, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38583064

RESUMO

The increasing prevalence of dry eye syndrome in aging and digital societies compromises long-term contact lens (CL) wear and forces users to regular eye drop instillation to alleviate discomfort. Here a novel approach with the potential to improve and extend the lubrication properties of CLs is presented. This is achieved by embedding lubricant-secreting biofactories within the CL material. The self-replenishable reservoirs autonomously produce and release hyaluronic acid (HA), a natural lubrication and wetting agent, long term. The hydrogel matrix regulates the growth of the biofactories and the HA production, and allows the diffusion of nutrients and HA for at least 3 weeks. The continuous release of HA sustainably reduces the friction coefficient of the CL surface. A self-lubricating CL prototype is presented, where the functional biofactories are contained in a functional ring at the lens periphery, outside of the vision area. The device is cytocompatible and fulfils physicochemical requirements of commercial CLs. The fabrication process is compatible with current manufacturing processes of CLs for vision correction. It is envisioned that the durable-by-design approach in living CL could enable long-term wear comfort for CL users and minimize the need for lubricating eye drops.


Assuntos
Ácido Hialurônico , Hidrogéis , Lubrificação , Ácido Hialurônico/química , Hidrogéis/química , Lubrificantes/química , Lentes de Contato , Humanos
18.
Biosens Bioelectron ; 257: 116284, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657379

RESUMO

Smart contact lenses (SCLs) have been considered as novel wearable devices for out-of-hospital and self-monitoring applications. They are capable of non-invasively and continuously monitoring physiological signals in the eyes, including vital biophysical (e.g., intraocular of pressure, temperature, and electrophysiological signal) and biochemical signals (e.g., pH, glucose, protein, nitrite, lactic acid, and ions). Recent progress mainly focuses on the rational design of wearable SCLs for physiological signal monitoring, while also facilitating the treatment of various ocular diseases. It covers contact lens materials, fabrication technologies, and integration methods. We also highlight and discuss a critical comparison of SCLs with electrical, microfluidic, and optical signal outputs in health monitoring. Their advantages and disadvantages could help researchers to make decisions when developing SCLs with desired properties for physiological signal monitoring. These unique capabilities make SCLs promising diagnostic and therapeutic tools. Despite the extensive research in SCLs, new technologies are still in their early stages of development and there are a few challenges to be addressed before these SCLs technologies can be successfully commercialized particularly in the form of rigorous clinical trials.


Assuntos
Técnicas Biossensoriais , Lentes de Contato , Dispositivos Eletrônicos Vestíveis , Humanos , Técnicas Biossensoriais/instrumentação , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Desenho de Equipamento
19.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38578134

RESUMO

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Assuntos
Lentes de Contato , Óculos , Fixação Ocular , Presbiopia , Leitura , Refração Ocular , Acuidade Visual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimentos Oculares/fisiologia , Fixação Ocular/fisiologia , Movimentos da Cabeça/fisiologia , Presbiopia/fisiopatologia , Presbiopia/terapia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Estudos Cross-Over , Estudos Prospectivos
20.
Cont Lens Anterior Eye ; 47(3): 102160, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38570253

RESUMO

PURPOSE: To investigate the differences in contact lens sagittal depth (CL-SAG), base curve (BC), and overall lens diameter (OAD) of daily disposable (DD) SCLs at room temperature (20 °C) and on-eye (34 °C) temperature. METHODS: Twelve different spherical daily SCLs were analyzed (labeled power -3.00 D) at 20 °C and 34 °C. The posterior CL-SAG, BC, and OAD were measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS: The CL-SAG range for the daily disposable lenses measured at 20 °C was 3468-4016 µm. At 34 °C, the DD CL-SAG of all lenses individually decreased compared to 20 °C (t = 7.78, p < 0.001), ranging from 3385 to 3913 µm. On average at the higher temperature, the measured overall lens diameter was smaller (t = 8.18, p < 0.001) and the BC was marginally steeper (t = 2.11, p = 0.058). CONCLUSIONS: Soft lens parameters change when equilibrated from room temperature (20 °C) to on-eye temperature (34 °C). All lenses shrink when going to on-eye temperature (both lens diameter and CL-SAG decreases), compared to lenses measured at room temperature by ISO standards. Higher water content materials tend to have greater changes to the lens parameters compared to lower water content material lenses.


Assuntos
Lentes de Contato Hidrofílicas , Equipamentos Descartáveis , Temperatura , Humanos , Tomografia de Coerência Óptica