Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
JSES Int ; 8(5): 1023-1028, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39280157

RESUMO

Background: Rotator cuff tears are highly prevalent, and their association with critical shoulder angle (CSA) has been reported. There is controversy regarding whether the morphology of the acromion influences its incidence, as well as whether acromioplasty would impact the results of a rotator cuff repair. Lateral acromioplasty does not play a decompressive role; rather, it aims to correct the deltoid vector. According to some publications, this would achieve less loading on the repaired rotator cuff, a lower retear rate, and better function. CSA correction with lateral acromioplasty can be planned with radiography (2-dimensional [2D]), but its predictability has not been fully studied. The primary objective of this study is to evaluate the predictability of 2D planning with radiography in CSA correction in patients with rotator cuff repair. The secondary objective is to analyze the association between the correction of the CSA and the functional outcomes. Methods: This single-center, prospective, observational, analytical study included candidates for arthroscopic repair of a rotator cuff tear with a CSA > 35°. Lateral acromioplasty was performed as planned with preoperative radiography (2D) to achieve a CSA of 35°. The degrees to be corrected were calculated. CSA was recalculated with a postoperative radiography; and the error in the planned grades to be corrected was calculated. At the end of follow-up, Visual Analog Scale, Subjective Shoulder Value (SSV), and Quick-Disabilities of the Arm, Shoulder, and Hand (Quick-DASH) scores were evaluated. Results: Forty one cases were included, 43.9% were men, and the mean age was 55.5 ± 8.6 years. The mean preoperative and postoperative CSA were 39.6° ± 1.9° and 35.7° ± 2.3°, respectively; 41.5% achieved a postoperative CSA ≤ 35°. The mean CSA planned correction error was 45.7 ± 28.8%. At the end of the follow-up, 33 (78.6%) had a functional evaluation, with an average follow-up of 41 ± 6.8 months. The mean Visual Analog Scale, Quick-DASH, and SSV were 0.9 ± 1.6, 5.3 ± 7.5, and 92.7 ± 10.6, respectively. There was a significant difference in Quick-DASH (P = .01) and SSV (P = .02) according to whether a postoperative CSA ≤ 35° was achieved. Conclusion: In lateral acromioplasty, planning of CSA correction with radiography (2D) is imprecise. Reaching a CSA ≤ 35° positively influences functional results.

2.
J Clin Med ; 13(17)2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39274508

RESUMO

Background/Objectives: Vesicoureteral reflux (VUR) is considered one of the major causes of post-renal transplant febrile urinary tract infections (UTI), leading to impaired renal function and the premature loss of the renal graft. We aimed to evaluate whether surgical VUR correction, such as open redo ureteric reimplantation, could be an option for treatment and provide better outcomes in post-transplant care for patients with UTI compared to their pre-VUR correction clinical state. Methods: Our study presents a retrospective analysis of 10 kidney transplant recipients with febrile UTI at the Renal Transplant Service of a Brazilian public hospital from 2010 to 2020. We selected patients who primarily underwent a surgical correction of post-transplant VUR, which was corrected by extravesical reimplantation without a stent in all patients by the same professional surgeon. Results: From 710 patients who received kidney transplants, 10 patients (1.4%) suffered from febrile UTI post-transplant and underwent surgical correction for VUR. Despite the study's limitations, such as its retrospective nature and limited sample size, the efficacy of open extravesical ureteral reimplantation in reducing post-operative febrile UTI in renal transplant patients was observed. Conclusions: As febrile UTI can contribute significantly to patient mortality after kidney transplantation and VUR emerges as a major cause of post-transplant febrile UTI, it is essential to treat it and consider the surgical outcome. This study emphasizes the timely detection and effective treatment of VUR via extravesical techniques to reduce febrile UTI occurrences post-transplant and it contributes insights into the role of surgical interventions in addressing VUR-related complications post-kidney transplantation.

3.
MethodsX ; 13: 102918, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39253001

RESUMO

The present article provides an improvement in the method to correct indirect strain measurements in triaxial compressive strength tests through axial displacement and hydraulic fluid volume change measurements. The improvement focused on reducing the parameters of the formula proposed for indirect volumetric strain in the original method, thereby facilitating the development of a simpler formula in which the radial strain depends on only two parameters: the initial volume of the rock specimen and the volume changes of the hydraulic fluid for each instant. The comparison between the improvement proposed, and original method resulted in a mean absolute difference of 0.003.•This improvement does not depend on the axial strain, unlike the original method, which requires correcting the indirect axial strain measurements before correcting the indirect radial strain measurements.•This improvement can be useful for research on the stress-strain behavior of intact rock under laboratory conditions, such as in the study of the post-peak state.

4.
BMC Public Health ; 24(1): 2228, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39152416

RESUMO

BACKGROUND: Sedentary behavior is linked to excess fat mass; however, this association may be inconclusive due to potential measurement errors in self-reported sedentary behavior. OBJECTIVE: To assess the association between changes in sedentary behavior and fat mass in a Cohort of Health Workers (HWCS) from 2004 to 2010. METHODS: A total of 1,285 adults participating in the Cohort of Health Workers were evaluated in 2004 and 2010. Fat mass (kg) was measured by dual X-ray absorptiometry. A self-administered questionnaire was used to estimate the sedentary behavior. Sedentary behavior was also estimated using accelerometry in a sample of 142 health workers. Accelerometry data were used to correct self-reported sedentary behavior using a generalized linear model, which included values for sleeping time, age, sex, sedentary behavior, glucose, and triglycerides. Concordance between both methods was assessed using a kappa and Bland-Altman analysis. Once sedentary behavior was corrected, the values were used to evaluate the association between changes in sedentary behavior and body fat mass using a fixed effect model in the cohort, adjusting for confounders. RESULTS: Self-reported sedentary behavior was 2.8 ± 1.8 and 2.3 ± 1.6 h/day, and body fat mass was 24.9 ± 8.1 and 26.8 ± 8.5 kg in 2004 and 2010, respectively. After applying the correction model, the self-reported sedentary behavior was 7.6 ± 1.2 and 7.5 ± 1.2 h/day in 2004 and 2010, respectively. For every hour increase in corrected sedentary behavior, there was an observed increase of 0.847 (p > 0.001) kg in body fat mass during the 6.8 years in the Cohort of Health Workers from 2004 to 2010. Conversely, non-corrected self-reported sedentary behavior was associated with a non-significant reduction of 0.097 kg (p = 0.228) for every hour of sedentary behavior. CONCLUSIONS: Increased sedentary behavior was associated with increased body fat mass when corrected self-reported sedentary behavior was used. Implementing public health strategies to reduce sedentary behavior is imperative.


Assuntos
Adiposidade , Comportamento Sedentário , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Acelerometria , Estudos de Coortes , Absorciometria de Fóton , Autorrelato , Inquéritos e Questionários
5.
NMR Biomed ; 37(11): e5203, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38953695

RESUMO

Proton MRS is used clinically to collect localized, quantitative metabolic data from living tissues. However, the presence of baselines in the spectra complicates accurate MRS data quantification. The occurrence of baselines is not specific to short-echo-time MRS data. In short-echo-time MRS, the baseline consists typically of a dominating macromolecular (MM) part, and can, depending on B0 shimming, poor voxel placement, and/or localization sequences, also contain broad water and lipid resonance components, indicated by broad components (BCs). In long-echo-time MRS, the MM part is usually much smaller, but BCs may still be present. The sum of MM and BCs is denoted by the baseline. Many algorithms have been proposed over the years to tackle these artefacts. A first approach is to identify the baseline itself in a preprocessing step, and a second approach is to model the baseline in the quantification of the MRS data themselves. This paper gives an overview of baseline handling algorithms and also proposes a new algorithm for baseline correction. A subset of suitable baseline removal algorithms were tested on in vivo MRSI data (semi-LASER at TE = 40 ms) and compared with the new algorithm. The baselines in all datasets were removed using the different methods and subsequently fitted using spectrIm-QMRS with a TDFDFit fitting model that contained only a metabolite basis set and lacked a baseline model. The same spectra were also fitted using a spectrIm-QMRS model that explicitly models the metabolites and the baseline of the spectrum. The quantification results of the latter quantification were regarded as ground truth. The fit quality number (FQN) was used to assess baseline removal effectiveness, and correlations between metabolite peak areas and ground truth models were also examined. The results show a competitive performance of our new proposed algorithm, underscoring its automatic approach and efficiency. Nevertheless, none of the tested baseline correction methods achieved FQNs as good as the ground truth model. All separately applied baseline correction methods introduce a bias in the observed metabolite peak areas. We conclude that all baseline correction methods tested, when applied as a separate preprocessing step, yield poorer FQNs and biased quantification results. While they may enhance visual display, they are not advisable for use before spectral fitting.


Assuntos
Algoritmos , Espectroscopia de Prótons por Ressonância Magnética , Espectroscopia de Prótons por Ressonância Magnética/métodos , Humanos , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem , Artefatos
6.
Gait Posture ; 113: 130-138, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38879895

RESUMO

BACKGROUND: In daily life tasks of the upper limb, we must make quick corrections with our hands in unstable postural situations. Postural and reaching control mechanisms are involved in the accurate execution of upper-limb tasks. RESEARCH QUESTION: This research aimed to determine the effect of different postural stability conditions on the motor performance of the upper limb in a reaching task with non-static targets. METHODOLOGY: 19 young participants performed a reaching task toward targets that exhibited a change in position (at 200 or 600 ms) in different postural conditions (bipedal-firm, bipedal-foam, and unipedal-foam surface). Performance on the screen (motion time and spatial error), balance (center of pressure displacements, CoP), and index finger movements were recorded during the reaching task. RESULTS: The instability affects the finger kinematic (displacements) and CoP kinematic (displacements, speed, and smoothness) without affecting the performance on the screen (precision and duration). The timing of target change affects the performance on the screen, finger kinematic (speed and smoothness), and CoP kinematic (displacements, speed, and smoothness). SIGNIFICANCE: Postural and reaching control systems enable accurate hand motions in less stable situations, even in reaching tasks with non-static targets. The postural and reaching control systems can protect the end-effector performance during unstable conditions but not during trials with less time to correct the motion.


Assuntos
Equilíbrio Postural , Desempenho Psicomotor , Humanos , Equilíbrio Postural/fisiologia , Fenômenos Biomecânicos , Masculino , Feminino , Adulto Jovem , Desempenho Psicomotor/fisiologia , Dedos/fisiologia , Adulto , Movimento/fisiologia , Extremidade Superior/fisiologia
7.
Distúrbios Comun. (Online) ; 36(1): 1-12, 17/06/2024.
Artigo em Inglês, Português | LILACS | ID: biblio-1560942

RESUMO

Introdução: A perda auditiva é uma deficiência comum na população mundial e contribui para dificuldade na comunicação verbal e redução da qualidade de vida, evidenciando a importância da identificação precoce, reabilitação e acompanhamento audiológico dessa deficiência para mitigar suas consequências. Durante a pandemia da COVID-19, as medidas restritivas diminuíram a capacidade de atendimento dos serviços de saúde auditiva e dificultaram a busca de auxílio para resolver problemas relacionados à adaptação aos dispositivos eletrônicos de amplificação sonora (DAES), sendo uma barreira no processo de reabilitação da perda auditiva. Objetivo: Caracterizar os usuários de DEAS e o processo inicial de reabilitação auditiva de adultos e idosos e verificar fatores associados ao retorno para a consulta de monitoramento auditivo durante o período inicial da pandemia da COVID-19.Métodos: Estudo observacional transversal com usuários adultos e idosos de um serviço ambulatorial de saúde auditiva com retorno para consulta de monitoramento auditivo agendada no período inicial da implementação das medidas restritivas da pandemia da COVID-19 no Brasil. Resultados: A maioria dos participantes conseguiu retornou para a consulta de monitoramento auditivo, sendo eles em sua maioria idosos, do sexo feminino e vacinados contra a COVID-19. Houve maior prevalência de adaptação adequada aos DAES. Não houve associação estatística entre as variáveis relacionadas à adaptação aos DAES, COVID-19 e saúde mental e o retorno à consulta de monitoramento auditivo. Conclusão: Os fatores relacionados à adaptação aos DAES, à COVID-19 ou à saúde mental não influenciaram o retorno à consulta de monitoramento auditivo na presente pesquisa. (AU)


Introduction: Hearing loss is a common disability in the world population and contributes to difficulty in verbal communication and reduced quality of life, highlighting the importance of early identification, rehabilitation and audiological monitoring of this disability to mitigate its consequences. During the COVID-19 pandemic, restrictive measures reduced the service capacity of hearing health services and made it difficult to seek help to solve problems related to adaptation to personal sound amplification products (PSAPs), being a barrier in the rehabilitation process of hearing loss. Aim: To characterize PSAPs users and the initial hearing rehabilitation process for adults and elderly people and verify the factors associated with the return to hearing monitoring consultations in the initial period of the COVID-19 pandemic. Methods: Cross-sectional observational study with adults and elderly people: elderly users of an outpatient hearing health service who return for a scheduled hearing monitoring consultation in the initial period of the implementation of restrictive measures of the COVID-19 pandemic in Brazil. Results: Most participants were able to return to the hearing monitoring clinic, the majority of whom were elderly, female and vaccinated against COVID-19. There was a higher prevalence of adequate adaptation to the PSAPs. There was no statistical association between variables related to adaptation to PSAPs, COVID-19 and mental health and return to hearing monitoring consultation. Conclusion: Factors related to adaptation to PSAPs, COVID-19 or mental health did not influence the return to hearing monitoring consultation in the present investigation. (AU)


Introducción: La pérdida auditiva es una discapacidad común en la población mundial y contribuye a la dificultad en la comunicación verbal y a la reducción de la calidad de vida, destacando la importancia de la identificación temprana, rehabilitación y seguimiento audiológico de esta discapacidad para mitigar sus consecuencias. Durante la pandemia de COVID-19, las medidas restrictivas redujeron la capacidad de atención de los servicios de salud auditiva y dificultaron la búsqueda de ayuda para resolver problemas relacionados con la adaptación a dispositivos electrónicos de amplificación del sonido (DEAS), siendo una barrera en el proceso de rehabilitación de la pérdida auditiva. Objetivo: Caracterizar a los usuarios de DEAS y el proceso inicial de rehabilitación auditiva de adultos y ancianos y verificar los factores asociados al retorno a las consultas de monitorización auditiva en el período inicial de la pandemia COVID-19. Métodos: Estudio observacional transversal con adultos y ancianos: ancianos usuarios de un servicio ambulatorio de salud auditiva que regresan para consulta de monitorización auditiva programada en el período inicial de la implementación de medidas restrictivas de la pandemia de COVID-19 en Brasil. Resultados: La mayoría de los participantes pudieron regresar a la clínica de monitorización auditiva, la mayoría de los cuales eran ancianos, mujeres y estaban vacunados contra COVID-19. Hubo mayor prevalencia de adaptación adecuada a la DEAS. No hubo asociación estadística entre variables relacionadas con adaptación a DEAS, COVID-19 y salud mental y retorno a consulta de monitorización auditiva. Conclusión: Los factores relacionados con la adaptación a DEAS, el COVID-19 o la salud mental no influyeron en el retorno a la consulta de monitorización auditiva en la presente investigación. (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Correção de Deficiência Auditiva , Acessibilidade aos Serviços de Saúde , Brasil , Assistência ao Paciente/métodos , COVID-19 , Perda Auditiva/reabilitação
8.
Surg Neurol Int ; 15: 145, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38741988

RESUMO

Background: Orbital hypertelorism is a rare congenital condition caused by craniofacial malformations. It consists of complete orbital lateralization, characterized by an increase in distance (above the 95th percentile) of the inner canthal (ICD), outer canthal, and interpupillary distances. It can be approached surgically, and the main techniques are box osteotomy and facial bipartition. The surgical procedure is usually performed before the age of 8. We describe here two patients who underwent late surgical correction using the box osteotomy technique. Case Description: Patient 1: A 13-year-old female presenting isolated hypertelorism with 5 cm ICD and left eye amblyopia. Patient 2: A 15-year-old female with orbital hypertelorism, 4.6 cm ICD, and nasal deformity. Both patients underwent orbital translocation surgery and had no neurological disorders. Conclusion: The article reports two cases of isolated hypertelorism treated late with the box osteotomy technique. Both surgeries were successful, with no postoperative complications. It appears that it is possible to obtain good surgical results even in patients who have not been able to undergo surgery previously.

9.
Methods Mol Biol ; 2726: 15-43, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38780726

RESUMO

The nearest-neighbor (NN) model is a general tool for the evaluation for oligonucleotide thermodynamic stability. It is primarily used for the prediction of melting temperatures but has also found use in RNA secondary structure prediction and theoretical models of hybridization kinetics. One of the key problems is to obtain the NN parameters from melting temperatures, and VarGibbs was designed to obtain those parameters directly from melting temperatures. Here we will describe the basic workflow from RNA melting temperatures to NN parameters with the use of VarGibbs. We start by a brief revision of the basic concepts of RNA hybridization and of the NN model and then show how to prepare the data files, run the parameter optimization, and interpret the results.


Assuntos
Conformação de Ácido Nucleico , Desnaturação de Ácido Nucleico , Termodinâmica , Temperatura de Transição , RNA/química , RNA/genética , Software , Algoritmos , Hibridização de Ácido Nucleico/métodos
10.
Biomed Phys Eng Express ; 10(3)2024 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-38507785

RESUMO

The aim of this study was to use computer simulation to analyze the impact of the aluminum fixing support on the Reference Air Kerma (RAK), a physical quantity obtained in a calibration system that was experimentally developed in the Laboratory of Radiological Sciences of the University of the State of Rio de Janeiro (LCR-UERJ). Correction factors due to scattered radiation and the geometry of the192Ir sources were also sought to be determined. The computational simulation was validated by comparing some parameters of the experimental results with the computational results. These parameters were: verification of the inverse square law of distance, determination of (RAKR), analysis of the source spectrum with and without encapsulation, and the sensitivity curve of the Sourcecheck 4PI ionization chamber response, as a function of the distance from the source along the axial axis, using the microSelectron-v2 (mSv2) and GammaMedplus (GMp) sources. Kerma was determined by activity in the Reference air, with calculated values of 1.725 × 10-3U. Bq-1and 1.710 × 10-3U. Bq-1for the ionization chamber NE 2571 and TN 30001, respectively. The expanded uncertainty for these values was 0.932% and 0.919%, respectively, for a coverage factor (k = 2). The correction factor due to the influence of the aluminum fixing support for measurements at 1 cm and 10 cm from the source was 0.978 and 0.969, respectively. The geometric correction factor of the sources was ksg= 1.005 with an expanded uncertainty of 0.7% for a coverage factor (k = 2). This value has a difference of approximately 0.2% compared to the experimental values.


Assuntos
Simulação por Computador , Radioisótopos de Irídio , Radiometria , Calibragem , Radiometria/métodos , Radioisótopos de Irídio/uso terapêutico , Humanos , Ar , Alumínio , Método de Monte Carlo , Doses de Radiação , Braquiterapia/métodos , Braquiterapia/normas , Dosagem Radioterapêutica , Espalhamento de Radiação
11.
Rev. CEFAC ; 26(2): e10423, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558996

RESUMO

ABSTRACT Purpose: to verify the association between types and degrees of hearing loss and demographic factors and categories of the International Classification of Functioning, Disability, and Health, related to "Body Structures and Functions" and "Activities and Participation." Methods: a cross-sectional, analytical, observational study with a nonprobabilistic sample, developed with secondary data, according to the International Classification of Functioning, Disability, and Health, obtained from the medical records of patients assessed for hearing rehabilitation at a specialized rehabilitation center. Descriptive and bivariate analyses were performed. Association analyses used Pearson's chi-square test, with the significance level set at 5%. Results: the study analyzed 122 medical records, which revealed a predominance of women, a sensorineural hearing loss of a moderately severe degree and progressive history. The type of hearing loss was associated with three categories of Body Structures and Functions and three categories of Activities and Participation. The degrees of hearing loss were associated with 10 categories of Body Structures and Functions and six categories of Activities and Participation. Conclusion: types and degrees of hearing loss are associated with Body Structures and Functions and Activities and Participation, further impairing communication.


RESUMO Objetivo: verificar a associação do tipo e grau de perda auditiva com os fatores demográficos e as categorias da Classificação Internacional de Funcionalidade, Incapacidade e Saúde relativas a "Estruturas e Funções do Corpo" e "Atividades e Participação". Métodos: trata-se de estudo observacional, analítico e transversal, com amostra não probabilística, desenvolvido com dados secundários, embasados na Classificação Internacional de Funcionalidade, Incapacidade e Saúde, obtidos no prontuário de usuários submetidos à avaliação para reabilitação auditiva, em um Centro Especializado em Reabilitação. Foram realizadas análises descritiva e bivariada. Para as análises de associação, foi utilizado o teste Qui-quadrado de Pearson com o nível de significância de 5%. Resultados: foram analisados 122 prontuários, que revelaram predominância de mulheres, perda auditiva do tipo neurossensorial de grau moderadamente severo e história progressiva. O tipo de perda auditiva apresentou associação com três categorias de Estruturas e Funções do corpo e três categorias de Atividades e Participação. Em relação ao grau da perda auditiva, dez categorias foram associadas com as Estruturas e Funções do corpo e seis categorias com as Atividades e Participação. Conclusão: o tipo e grau da perda auditiva associam-se com as Estruturas e Funções do corpo e com as Atividades e Participação, com maior prejuízo na comunicação.

12.
Rev. cuba. oftalmol ; 36(4)dic. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550949

RESUMO

La presbicia es la pérdida gradual y progresiva de la amplitud de acomodación del cristalino que comienza entre los 38 y 40 años de edad y culmina a los 55 años al perderse por completo. Es provocada por el aumento de rigidez del cristalino y, en particular, un mayor cambio en la rigidez del núcleo de su corteza. La presbicia no corregida o hipocorregida tiene un impacto negativo en la calidad de vida en relación con la visión, las personas afectadas experimentan un cambio positivo significativo de productividad en sus actividades diarias al utilizar una corrección óptica adecuada. Las diferentes alternativas de tratamiento deben aplicarse de forma personalizadas para optimizar el rango de enfoque para las tareas diarias, minimizar los efectos visuales adversos y cumplir con las expectativas del paciente según necesidades y alcance económico. Los tratamientos más efectivos y con menos efectos indeseables hasta el momento son los dispositivos ópticos como las gafas y las lentes de contacto. Los métodos quirúrgicos pueden dejar síntomas visuales. El objetivo de este estudio fue realizar una búsqueda bibliográfica sobre las actuales tendencias en el manejo clínico-quirúrgico de la presbicia(AU)


Presbyopia is the gradual and progressive loss of the accommodative range of the crystalline lens that begins between 38 and 40 years of age and culminates at 55 years of age when it is completely lost. It is caused by increased stiffness of the lens and, in particular, a greater change in the stiffness of the nucleus of its cortex. Uncorrected or undercorrected presbyopia has a negative impact on quality of life in relation to vision, affected individuals experience a significant positive change in productivity in their daily activities when using an appropriate optical correction. The different treatment alternatives should be applied in a personalized way to optimize the range of focus for daily tasks, minimize adverse visual effects and meet the patient's expectations according to needs and economic scope. The most effective treatments with the least undesirable effects so far are optical devices such as glasses and contact lenses. Surgical methods may leave visual symptoms. The aim of this study was to perform a literature search on current trends in the clinical-surgical management of presbyopia(AU)


Assuntos
Humanos , Presbiopia , Literatura de Revisão como Assunto
13.
Acta Ortop Mex ; 37(2): 79-84, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37871930

RESUMO

The need for total knee arthroplasty is increasing considerably and one of the goals is to achieve post-surgical coronal alignment. Robotic surgical assistance achieves a functional alignment, which is a hip-knee-ankle angle of 0°. However, it is not possible to provide robotic assisted surgery to all our patients so we must include the full-length hip-to-ankle AP weight-bearing radiograph in preoperative planning to obtain a "safe zone" alignment, which is a post-surgical hip-knee-ankle Angle of 0 ± 3°. How can we achieve a "safe zone" alignment total knee arthroplasty in patients with extra-articular deformity?


La necesidad de artroplastia total de rodilla está aumentando considerablemente y uno de los objetivos es lograr la alineación coronal postquirúrgica. La asistencia quirúrgica robótica consigue una alineación funcional, que es un ángulo cadera-rodilla-tobillo de 0°. Sin embargo, no es posible ofrecer cirugía asistida por robot a todos nuestros pacientes, por lo que debemos incluir la radiografía AP de soporte de peso de cadera a tobillo de cuerpo entero en la planificación preoperatoria para obtener una alineación de "zona segura", que es un ángulo postquirúrgico cadera-rodilla-tobillo de 0 ± 3°. ¿Cómo podemos conseguir una artroplastia total de rodilla con alineación de "zona segura" en pacientes con deformidad extraarticular?


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia
14.
Diagnostics (Basel) ; 13(13)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37443608

RESUMO

(1) Background: The CT-based attenuation correction of SPECT images is essential for obtaining accurate quantitative images in cardiovascular imaging. However, there are still many SPECT cameras without associated CT scanners throughout the world, especially in developing countries. Performing additional CT scans implies troublesome planning logistics and larger radiation doses for patients, making it a suboptimal solution. Deep learning (DL) offers a revolutionary way to generate complementary images for individual patients at a large scale. Hence, we aimed to generate linear attenuation coefficient maps from SPECT emission images reconstructed without attenuation correction using deep learning. (2) Methods: A total of 384 SPECT myocardial perfusion studies that used 99mTc-sestamibi were included. A DL model based on a 2D U-Net architecture was trained using information from 312 patients. The quality of the generated synthetic attenuation correction maps (ACMs) and reconstructed emission values were evaluated using three metrics and compared to standard-of-care data using Bland-Altman plots. Finally, a quantitative evaluation of myocardial uptake was performed, followed by a semi-quantitative evaluation of myocardial perfusion. (3) Results: In a test set of 66 test patients, the ACM quality metrics were MSSIM = 0.97 ± 0.001 and NMAE = 3.08 ± 1.26 (%), and the reconstructed emission quality metrics were MSSIM = 0.99 ± 0.003 and NMAE = 0.23 ± 0.13 (%). The 95% limits of agreement (LoAs) at the voxel level for reconstructed SPECT images were: [-9.04; 9.00]%, and for the segment level, they were [-11; 10]%. The 95% LoAs for the Summed Stress Score values between the images reconstructed were [-2.8, 3.0]. When global perfusion scores were assessed, only 2 out of 66 patients showed changes in perfusion categories. (4) Conclusion: Deep learning can generate accurate attenuation correction maps from non-attenuation-corrected cardiac SPECT images. These high-quality attenuation maps are suitable for attenuation correction in myocardial perfusion SPECT imaging and could obviate the need for additional imaging in standalone SPECT scanners.

15.
Sci Eng Ethics ; 29(4): 26, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37403005

RESUMO

In recent years, the changing landscape for the conduct and assessment of research and of researchers has increased scrutiny of the reward systems of science. In this context, correcting the research record, including retractions, has gained attention and space in the publication system. One question is the possible influence of retractions on the careers of scientists. It might be assessed, for example, through citation patterns or productivity rates for authors who have had one or more retractions. This is an emerging issue today, with growing discussions in the research community about impact. We have explored the influence of retractions on grant review criteria. Here, we present results of a qualitative study exploring the views of a group of six representatives of funding agencies from different countries and of a follow-up survey of 224 reviewers in the US. These reviewers have served on panels for the National Science Foundation, the National Institutes of Health, and/or a few other agencies. We collected their perceptions about the influence of self-correction of the literature and of retractions on grant decisions. Our results suggest that correcting the research record, for honest error or misconduct, is perceived as an important mechanism to strengthen the reliability of science, among most respondents. However, retractions and self-correcting the literature at large are not factors influencing grant review, and dealing with retractions in reviewing grants is an open question for funders.


Assuntos
Pesquisa Biomédica , Má Conduta Científica , Estados Unidos , Reprodutibilidade dos Testes , National Institutes of Health (U.S.) , Organização do Financiamento
18.
Medwave ; 20(5)2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37339464

RESUMO

Hypokalemia is a common electrolyte disorder in cancer patients that may be associated with the primary disease or a complication of treatment. In this article, we provide a brief description of hypokalemia and its appropriate management in cancer patients.


La hipokalemia es un trastorno hidroelectrolítico común en pacientes con cáncer que puede estar asociado a la enfermedad primaria o a una complicación del tratamiento. En este artículo nos enfocamos en entregar una breve descripción de la hipokalemia y su adecuado manejo en pacientes con cáncer.


Assuntos
Hipopotassemia , Neoplasias , Humanos , Hipopotassemia/terapia , Hipopotassemia/complicações , Neoplasias/complicações
19.
Medwave ; 23(5): e2669, 30-06-2023. tab
Artigo em Inglês | LILACS | ID: biblio-1438267

RESUMO

Hypokalemia is a common electrolyte disorder in cancer patients that may be associated with the primary disease or a complication of treatment. In this article, we provide a brief description of hypokalemia and its appropriate management in cancer patients.


La hipokalemia es un trastorno hidroelectrolítico común en pacientes con cáncer que puede estar asociado a la enfermedad primaria o a una complicación del tratamiento. En este artículo nos enfocamos en entregar una breve descripción de la hipokalemia y su adecuado manejo en pacientes con cáncer.


Assuntos
Humanos , Hipopotassemia/complicações , Hipopotassemia/terapia , Neoplasias/complicações
20.
Acta ortop. mex ; 37(2): 79-84, mar.-abr. 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1556736

RESUMO

Abstract: The need for total knee arthroplasty is increasing considerably and one of the goals is to achieve post-surgical coronal alignment. Robotic surgical assistance achieves a functional alignment, which is a hip-knee-ankle angle of 0o. However, it is not possible to provide robotic assisted surgery to all our patients so we must include the full-length hip-to-ankle AP weight-bearing radiograph in preoperative planning to obtain a «safe zone¼ alignment, which is a post-surgical hip-knee-ankle Angle of 0 ± 3o. How can we achieve a «safe zone¼ alignment total knee arthroplasty in patients with extra-articular deformity?


Resumen: La necesidad de artroplastia total de rodilla está aumentando considerablemente y uno de los objetivos es lograr la alineación coronal postquirúrgica. La asistencia quirúrgica robótica consigue una alineación funcional, que es un ángulo cadera-rodilla-tobillo de 0o. Sin embargo, no es posible ofrecer cirugía asistida por robot a todos nuestros pacientes, por lo que debemos incluir la radiografía AP de soporte de peso de cadera a tobillo de cuerpo entero en la planificación preoperatoria para obtener una alineación de «zona segura¼, que es un ángulo postquirúrgico cadera-rodilla-tobillo de 0 ± 3o. ¿Cómo podemos conseguir una artroplastia total de rodilla con alineación de «zona segura¼ en pacientes con deformidad extraarticular?

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA