Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
J. optom. (Internet) ; 17(3): [100497], jul.-sept2024. graf, tab
Artigo em Inglês | IBECS | ID: ibc-231871

RESUMO

Purpose: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. Methods: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. Results: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p = 0.012) and -0.11±0.12 D (YG, p = 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p = 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. Conclusion: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.(AU)


Assuntos
Humanos , Masculino , Feminino , Adulto Jovem , Idoso , Visão Ocular , Acuidade Visual , Fundo de Olho , Lentes de Contato , Testes Visuais
2.
Am J Ophthalmol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851443

RESUMO

PURPOSE: To compare intraindividual monocular visual performance of a monofocal EDOF and a trifocal EDOF IOL following bilateral cataract surgery. DESIGN: Single-center, prospective, fellow-eye comparison clinical trial. METHODS: All patients received uneventful bilateral cataract surgery with implantation of the monofocal EDOF Isopure IOL in the dominant eye and the trifocal EDOF FineVision Triumf IOL in the non-dominant eye. Intraindividual monocular comparison included visual acuity at various distances, defocus curves, internal total higher-order aberration (HOA), spherical aberration (SA) Z(4.0), IOL decentration and tilt. Additionally, subjective outcomes were evaluated using Halo and Glare simulation and the VF-7 questionnaire. RESULTS: In total, 25 patients (50 eyes) were included. Intraindividual monocular BCDVA, DCIVA, and BCNVA were comparable (p> .05). However, monocular contrast acuity (p= .019), DCNVA (p< .001) and defocus curves at defocus levels of 0.0D (p= .005) and between -1.5 and -4.0D (p< .001) differed significantly. At 5mm, internal HOA and SA Z(4.0) were significantly different (p< .001) and comparable at 3mm pupil diameter, as were IOL tilt and decentration (p> .05). CONCLUSION: In this combined fellow-eye comparison, near vision was significantly better with the trifocal EDOF IOL. The monofocal EDOF IOL demonstrated similar distance and intermediate visual performance as the trifocal EDOF IOL. Overall, low values of photic phenomena and visual impairment was observed.

3.
Cont Lens Anterior Eye ; : 102156, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38641525

RESUMO

It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.

4.
Cesk Slov Oftalmol ; 80(2): 93-102, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38531682

RESUMO

PURPOSE: To compare objective quality of vision in patients undergoing phacoemulsification with implantation of a bilateral segmented multifocal intraocular lens (SMIOL). METHODS: A retro-prospective study included 110 eyes of 55 patients who underwent cataract surgery with bilateral SMIOL implantation. Patients were divided according to the type of implanted intraocular lens into group 1 (SBL-2, 62 eyes) and group 2 (SBL-3, 48 eyes). Postoperatively, monocular and binocular uncorrected distance visual acuity (UCDVA), corrected distance visual acuity (BCDVA), uncorrected intermediate visual acuity (UCIVA, at 66 cm), uncorrected near visual acuity (UCNVA, at 40 cm), corrected near visual acuity (BCNVA) and defocus curve were measured and evaluated. The follow-up period was 6 months. RESULTS: Mean UCDVA in group 1 (SBL-2) was 0.010 ±0.15 LogMAR monocularly, 0.01 ±0.10 LogMAR binocularly, and in group 2 (SBL-3) was 0.02 ±0.11 LogMAR monocularly and -0.07 ±0.09 LogMAR binocularly. Binocular defocus curves showed that the SBL-3 group performed better than the SBL-2 lens at a vergence of -1.50 D corresponding to 66 cm (center distance), averaging 0.03 ±0.11 LogMAR, while the SBL-2 group averaged 0.12 ±0.14 LogMAR (p = 0.01). The -2.50 D vergence characterizing near vision (40 cm) was achieved by the SBL-2 lens in our study at 0.33 ±0.15 LogMAR and by the SBL-3 lens at 0.00 ±0.11 LogMAR (p = 0.00). CONCLUSION: Both SMIOLs provided very good vision at all tested distances 6 months postoperatively. The SBL-2 lens performed better in UCIVA, while the SBL-3 lens excelled in UCDVA and UCNVA.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Prospectivos , Refração Ocular , Acuidade Visual , Desenho de Prótese , Visão Binocular
5.
BMC Ophthalmol ; 24(1): 86, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409015

RESUMO

BACKGROUND: To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS: Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS: Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION: There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Microscopia Eletrônica de Varredura , Implante de Lente Intraocular , Pseudofacia/cirurgia , Visão Binocular , Refração Ocular , Desenho de Prótese
6.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1539-1544, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38038729

RESUMO

PURPOSE: To compare the refractive power profile, subjective depth-of-field and objective optical quality of two advanced monofocal intraocular lenses (IOLs) designed to improve intermediate vision. METHODS: This prospective study evaluated forty-six eyes of twenty-three patients, aged 54-68 years, binocularly implanted with two monofocal enhanced intraocular lenses (IOLs), the Tecnis Eyhance and the Physiol Isopure. Subjective through-focus visual acuity curves were obtained by placing trial lenses in front of the eye while wearing its best spherical-cylindrical correction for distance. Objective optical quality was defined as the area under the modulation transfer function, calculated from the wavefront maps measured with a high-resolution aberrometer. The optical design of both lenses was compared based on their refractive power profiles measured with the lenses immersed in saline solution. RESULTS: Both lenses have progressive aspherical geometries, in which the sagittal power decreases rapidly from the center to the edge of the optical zone. Mean monocular through-focus curves show a best corrected distance visual acuity of - 0.02 logMAR with both lenses. Through-focus visual acuity was marginally higher for the Eyhance, with a difference of 1 letter at the defocus position of - 0.5D and 3 letters between - 1.0D and - 2.0D. Objective assessment of optical quality revealed only a difference of about 2 points in MTF area at distance. CONCLUSION: Both IOLs use a similar approach to improve intermediate vision. The Eyhance showed marginally better subjective performance than the Isopure at the target vergences between - 1.00D and - 2.00D, although these results did not reach statistical significance and were not replicated by the objective findings.

7.
J Optom ; 17(3): 100497, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38128434

RESUMO

PURPOSE: To compare the eye defocus curves (DCs) obtained with stimuli on red, green, and white backgrounds and to investigate the applicability of the duochrome test (DT) in different age groups. METHODS: 12 elderly (ELD: 59.3 ± 3.9 years) and 8 young (YG: 22.1 ± 1.1 years) subjects were recruited. An optometric assessment with the DT was carried out to obtain the subjective refraction at distance. DCs at distance on green, white, and red backgrounds were measured and the following parameters were deduced: dioptric difference between red-green, green-white, red-white focal positions (minima of the DCs), best corrected visual acuity (BCVA), and widths of the DCs for red, green, and white. RESULTS: The DC difference between the green-white focal positions (mean ± standard deviation) was -0.12±0.17 diopters (D) (ELD, p= 0.012) and -0.11±0.12 D (YG, p= 0.039), while the red-white difference was not statistically significant. The DC red-green difference was 0.20±0.16 D (ELD, p= 0.002) and 0.18±0.18 D (YG, p = 0.008). The ELD BCVA with green background was significantly worse than BCVA with red (p = 0.007) and white (p = 0.007). The mean value of the DC's width in ELD for green (1.01±0.36 D) was higher than for red (0.77±0.21 D) and for white (0.84±0.35 D), but with no statistical significance. CONCLUSION: Both age groups showed a slight focusing preference for red when using white light. Moreover, ELD showed a worse BCVA with a green compared to a red background. Despite these results deduced by DC analyses, these aspects do not compromise the possibility of using the DT in clinical practice both in the young and in the elderly. Furthermore, the difference of about 0.20 D between red-green DC in both groups confirms the clinical appropriateness of the widespread use of 0.25 D step as the standard minimum difference in power between correcting lenses.


Assuntos
Refração Ocular , Acuidade Visual , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Acuidade Visual/fisiologia , Masculino , Feminino , Refração Ocular/fisiologia , Adulto , Idoso , Testes Visuais/métodos , Envelhecimento/fisiologia
8.
International Eye Science ; (12): 106-110, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1003516

RESUMO

AIM: To compare the short-term postoperative visual acuity, visual disturbance phenomena, and spectacle independence rate in patients who underwent monocular implantation with trifocal, multifocal, or extended range of vision intraocular lens(IOL).METHODS: A retrospective analysis was conducted on 67 cataract patients(67 eyes)who underwent phacoemulsification cataract extraction combined with IOL implantation from March 2019 to December 2022. A total of 35 cases(35 eyes)received Symfony extended range of vision IOL implantation, 21 cases(21 eyes)received AcrySof IQ ReSTOR +3D multifocal IOL, and 11 cases(11 eyes)received AcrySof IQ PanOptix trifocal IOL. The preoperative uncorrected distance visual acuity(UDVA), uncorrected intermediate visual acuity(UIVA), and uncorrected near visual acuity(UNVA)and 3 mo postoperatively were documented. Moreover, defocus curves, visual disturbance phenomena, and spectacle independence rates were recorded at 3 mo postoperatively.RESULTS: At 3 mo postoperatively, no statistically significant differences were observed in UDVA among the three groups(P&#x0026;#x003E;0.05). A comparison of UIVA showed superior results in the Symfony and PanOptix groups compared to the ReSTOR group(all P&#x0026;#x003C;0.01). The UNVA of both the ReSTOR and PanOptix groups outperformed the Symfony group(all P&#x0026;#x003C;0.01). The defocus curves indicated that in the intermediate vision range(-1.00 to -1.50 D), the Symfony group exhibited better performance than the ReSTOR group(P&#x0026;#x003C;0.05); while in the near vision range(-2.50 to -3.50 D), the ReSTOR group was superior to the Symfony group(P&#x0026;#x003C;0.05). The PanOptix group demonstrated superior visual acuity in the near vision range(-2.00 to -3.50 D)compared to the Symfony group(P&#x0026;#x003C;0.05)and was also superior in the intermediate vision range(-1.00 to -2.00 D)compared to the ReSTOR group(P&#x0026;#x003C;0.05). No significant differences were observed in the incidence of glare or halo and binocular interference phenomena among the three groups(P&#x0026;#x003E;0.05). The PanOptix and ReSTOR groups exhibited a higher spectacle independence rate compared to the Symfony group(P&#x0026;#x003C;0.0167).CONCLUSION: Compared to Symfony extended range of vision IOL and ReSTOR multifocal IOL, PanOptix trifocal IOL offers a balanced approach to distance, intermediate, and near visual acuity, without a high incidence of glare and halo, and with a higher spectacle independence rate. Caution is still advised when considering monocular implantation with presbyopia-correcting IOLs.

9.
Clin Ophthalmol ; 17: 3531-3542, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026604

RESUMO

Purpose: To investigate the visual acuity and satisfaction of patients after Zhang & Zheng's corneal laser-enhanced accommodation refraction Q (ZZ-CLEAR-Q) surgery utilizing differential modulation of binocular longitudinal spherical aberration and determine its clinical significance. Patients and Methods: This prospective observational study enrolled a consecutive cohort of patients with presbyopia who underwent ZZ-CLEAR-Q surgery between December 2020 and January 2023. The study assessed visual acuity, distance-corrected defocus curve, satisfaction, Q factor, manifest spherical equivalent, and primary spherical aberration, among others, at 3 months postoperatively. Additionally, the study conducted a binocular comparison to analyze the clinical significance of setting the different longitudinal spherical aberrations. Results: A total of 232 eyes of 116 patients were included. The binocular uncorrected distance visual acuity was 20/20 for all patients. At 3 months postoperatively, the binocular uncorrected near visual acuity was Jaeger 1 for 96% of the patients and Jaeger 2 for 100% of the patients. Furthermore, 93.1% of the patients expressed satisfaction. The monocular distance-corrected defocus curve revealed that the dominant eyes had significantly better visual acuity at 0 D (P<0.001), while the non-dominant eyes had significantly better visual acuity across various defocus levels except 0 and -0.50 D (All P<0.05). At 3 months, there were no significant differences between the expected and achieved manifest spherical equivalents, corneal Q factor values, and ocular primary spherical aberration values of both groups. Conclusion: Patients with presbyopia who underwent ZZ-CLEAR-Q surgery were likely to achieve normal uncorrected visual acuity and be satisfied. The increased depth of field has clinical significance for assisting near vision.

10.
Clin Ophthalmol ; 17: 2231-2242, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37559778

RESUMO

Purpose: To assess refractive and visual outcomes of bilateral implantation of an isofocal optic-design intraocular lens (IOL) or a monofocal IOL following cataract surgery. Methods: A total of 127 patients were recruited into a prospective, single-masked, randomized trial. Sixty-five patients bilaterally implanted with the Isopure Isofocal IOL and 62 patients with the Micropure Monofocal IOL were followed for 4-6 months. Refraction, monocular and binocular uncorrected-distance-visual acuity, corrected-distance-visual acuity (CDVA), uncorrected-intermediate-visual acuity and distance-corrected-intermediate-visual acuity (DCIVA, 66/80 cm), uncorrected-near-visual acuity, and distance-corrected-near-visual acuity (DCNVA, 40 cm) were evaluated. Binocular defocus curve, binocular contrast sensitivity (photopic, mesopic with/without glare), and glare and halo phenomena were also measured. Results: 99.23% of eyes were within ±1.00D and 84.62% of eyes within ±0.50D for the Isopure patients and 98.39% and 82.26% for the Micropure patients, respectively. The mean spherical-equivalent was -0.06 ± 0.36D and 0.10 ± 0.32D for the Isopure and Micropure patients, respectively. 98.5% and 100% of patients implanted with the Isopure and Micropure IOLs showed a cumulative binocular CDVA value ≥20/20, respectively. 80% and 67.70% of patients implanted with the Isopure presented a binocular DCIVA ≥20/25 at 80 and 66 cm, respectively. These percentages were 46.8% and 40.3% with the Micropure IOL, respectively. For Isopure, 7.7%, 30.8%, and 58.5% of patients presented a DCNVA ≥20/25, ≥20/32 and ≥20/40, respectively. These values were lower for the Micropure: 1.6%, 19.4% and 46.8%, respectively. Defocus curves showed similar good visual acuity at distance for both lenses with better intermediate vision for the Isopure. Both groups presented good contrast sensitivity, and the size and intensity of halo and glare phenomena were similar between the two. No adverse-events were reported. Conclusion: Our trial shows that both IOLs provide excellent visual acuity and contrast sensitivity for far vision with similar photic phenomena, and the Isopure IOL improved unaided intermediate vision performance.

11.
Saudi Med J ; 44(5): 456-462, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37182920

RESUMO

OBJECTIVES: To compare the subjective and objective visual quality more comprehensively after surgery of the commonly used multifocal intraocular lenses (IOL) and monolocal IOL implants through long-term systematic clinical observation, providing reference and basis for clinical application. METHODS: Non-randomized controlled trial. A total of 91 (138 eyes) patients between June 2020 and December 2020 were implanted trifocal IOL or monofocal IOL after phacoemulsification in a tertiary class hospital in Wuhan. Monocular testing 3 months after surgery included best-spectacles corrected and uncorrected visual at distant, intermediate, and near vision; spherical equivalent (SE); defocus curve; modulation transfer function (MTF); dysfunctional lens index (DLI); Strehl ratio (SR); mesopic contrast sensitivity function; quality-of-life, spectacles independence, visual disturbance, and surgical satisfaction surveys 3 months post-surgery. RESULTS: There was statistically better uncorrected vision acuity with trifocal IOLs in all range, while monofocal IOL had statistically better mesopic contrast sensitivity at specific spatial frequencies and statistically worse defocus curves, spectacles independence, and surgical satisfaction. The trifocal IOL performed better in subjective quality of vision and life and spectacles independence questionnaires, and the objective quality of vision had no statistical significance. CONCLUSION: Compared to monofocal IOL, trifocal IOL could provide a full range of clear vision for the majority of patients with simple cataracts, improve the rate of spectacles independence and patient satisfaction. And the objective quality of vision did not show any difference.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Estudos Prospectivos , Acuidade Visual , Sensibilidades de Contraste , Satisfação do Paciente , Desenho de Prótese
12.
Eye Vis (Lond) ; 10(1): 5, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36721199

RESUMO

BACKGROUND: The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus (EDOF) and monofocal intraocular lens (IOL). METHODS: A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony (ZXR00) or monofocal IOLs were enrolled. The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively. RESULTS: The ZXR00 group achieved significantly better intermediate (P = 0.044) and near (P = 0.017) visual acuity (VA) than the monofocal group. Two groups had similar uncorrected and corrected distance VA (P > 0.05, respectively). The dynamic defocus curve revealed a smoother decline from 0.0 D to - 2.0 D in the ZXR00 group. Defocused dynamic VA in the ZXR00 group was significantly better (P < 0.05) except at 0.0 D (P = 0.724) and - 0.5 D (P = 0.176). The area under the curve (P = 0.002) and corrected dynamic vision accommodation (P = 0.001) derived from the dynamic defocus curves were better in the ZXR00 group. A positive correlation was observed between defocused dynamic and static VA in both groups (P < 0.001). Multiple linear regression analysis indicated that defocused static VA and corrected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from - 1.0 D to - 3.0 D (P < 0.05). CONCLUSIONS: The EDOF IOL provided similar distance vision, better intermediate and near vision, and a better overall dynamic defocus curve than the monofocal IOL. The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.

13.
International Eye Science ; (12): 312-315, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-960957

RESUMO

AIM: To evaluate the clinical efficacy of femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation.METHODS:The retrospective study enrolled 22 cases(26 eyes)of cataract patients who underwent femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation from August 2020 to August 2021. Follow-up to 3mo after surgery, the changes of far, intermediate and near visual acuity, aberration, Strehl ratio(SR)and modulation transfer function cutoff(MTF-cutoff)frequency were compared. Defocus curve at 1mo postoperatively was made, and the visual quality and satisfaction were evaluated after 3mo of surgery.RESULTS: The visual acuity of all patients was better than 0.1(LogMAR)at the far, intermediate and near distance at 1d, 1wk, 1 and 3mo postoperatively, and it was significantly improved compared with those before surgery(all P&#x0026;#x003C;0.01). The defocus curve transitioned smoothly between +0.5 and -3.0D at 1mo after surgery, and visual acuity was better than 0.63. The total aberration and spherical aberration in the whole eye were significantly lower after surgery than before, and the SR and MTF-cutoff were significantly improved at 1d and 1wk after surgery(all P&#x0026;#x003C;0.05). With high satisfaction and good visual quality, patients could watch at far, intermediate and near distance without wearing glasses at 3mo after surgery.CONCLUSION: Femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation gave patients a comfortable and satisfactory full-course vision.

14.
Clin Ophthalmol ; 16: 3945-3950, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36466083

RESUMO

Purpose: To evaluate the long-term (>1 yr) outcomes a non-diffractive extended vision intraocular lens (AcrySof IQ Vivity) compared to monofocal control. Setting: This was a multicenter trial that took place in 4 separate private ophthalmology practices throughout the United States. Design: This was a prospective, non-interventional, controlled, multicenter trial. All subjects were enrolled from participants in the Food and Drug Administration (FDA) clinical trial that led to the approval of the AcrySof IQ Vivity. Methods: Binocular uncorrected distance visual acuity (UCDVA), distance corrected visual acuity (DCVA), uncorrected intermediate visual acuity (UIVA) at 66cm, distance corrected intermediate visual acuity (DCIVA) at 66cm, uncorrected near visual acuity (UNVA) at 40cm, and distance corrected near visual acuity (DCNVA) at 40cm were measured. The binocular defocus curve was measured. A 23-question survey on visual performance including questions on spectacle independence, satisfaction, dysphotopsias, and likelihood of recommending their lens to another person was used administered. Results: A total of 64 eyes of 32 subjects were enrolled. Seventeen subjects had bilateral implantation of the AcrySof IQ Vivity lens, and 15 subjects had bilateral implantation of the AcrySof IQ Monofocal (SN60WF). Mean follow up time was 1078 days for the study group compared to 1067 days for the control group (p = 0.92). There were no differences in UCVA or DCVA between the two groups. Compared to control, the AcrySof IQ Vivity group had better mean binocular UIVA (logMAR 0.29 vs 0.18; p = 0.09), DCIVA (logMAR 0.33 vs 0.11; p = 0.003), UNVA (logMAR 0.49 vs 0.30, p = 0.01), and DCNVA (logMAR 0.54 vs 0.29; p = 0.001). Conclusion: The AcrySof IQ Vivity is a novel, non-diffractive extended range of vision intraocular lens that provides long-term, enhanced visual acuity at intermediate and near ranges with high levels of patient satisfaction and minimal dysphotopsias.

15.
Eur J Ophthalmol ; : 11206721221136428, 2022 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-36314450

RESUMO

PURPOSE: To report our first clinical and patient-reported outcomes in the early postoperative period with a new model of trifocal diffractive intraocular lens (IOL). METHODS: Pilot prospective analysis of the results of 26 eyes of 13 patients (age, 44-79 years) undergoing cataract surgery with implantation of the trifocal diffractive IOL Liberty 677MY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary). The following clinical outcomes were evaluated during the first postoperative month: measurement of distance, intermediate and near visual acuity, binocular defocus curve, and level of spectacle independence, patient satisfaction, perception of photic phenomena, and difficulty in performing several vision-related daily tasks by means of a questionnaire. RESULTS: Mean binocular LogMAR uncorrected distance, intermediate and near visual acuities were -0.03 ± 0.13, 0.21 ± 0.16, and 0.16 ± 0.09, respectively. Furthermore, 100.0%, 84.6% and 92.3% of patients achieved a binocular corrected distance, distance-corrected intermediate and distance-corrected near visual acuity of 20/32 or better, respectively. In the defocus curve, visual acuities were better than 0.2 logMAR for defocus levels between +1.00 and -3.00 D. Spectacle independence was referred by all patients, with any of them reporting dissatisfaction with the outcome of the surgery. The postoperative vision did not lead to difficulties in the daily life in 92.3% of patients. Bothersome halos, glare or starbursts were only reported by only 7.7% of patients. CONCLUSIONS: The trifocal IOL evaluated provides a successful visual rehabilitation with minimal photic phenomena associated, leading to high levels of spectacle independence and patient satisfaction.

16.
Indian J Ophthalmol ; 70(8): 2867-2871, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35918933

RESUMO

Purpose: To compare four different types of intra ocular lenses (IOLs), namely, AT LISA, Eyecryl SERT trifocal, Eyhance, Eyecryl SERT extended depth of focus (EDOF) with respect to their clinical outcomes. Methods: This is a retrospective comparative study in which patients who underwent surgery and one of the four types of IOL were implanted. Postoperative evaluation was recorded at one month, postoperatively. The monocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (6 m), uncorrected intermediate visual acuity (UIVA) (60 cm), distance-corrected intermediate visual acuity (CIVA), uncorrected near visual acuity (UNVA) (40 cm), and corrected near visual acuity (CNVA) were assessed postoperatively on post operative day 30, for all four IOL groups. Defocus curve and contrast sensitivity were also compared. Results: With regards to UDVA and CDVA, P value was not statistically significant. (P = 0.534 and 0.421, respectively). EDOF group of IOLs had statistically significant better UIVA and CIVA than trifocal IOL group. (P < 0.001, 0.012, <0.001) and EDOF group had statistically significant worse P value pertaining to UNVA and CNVA (P < 0.001, 0.070, <0.001, 0.190). Pertaining to contrast sensitivity, EDOF group had better contrast sensitivity than Trifocal IOL group (P < 0.001). Conclusion: All four IOLs compared in this study had good comparable distant visual acuity. Near visual acuity was better with AT LISA and Eyecryl SERT trifocal IOL while intermediate vision was better with Eyhance and Eyecryl SERT EDOF IOL. Contrast sensitivity was better in EDOF IOLs than in both trifocal IOLs.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Satisfação do Paciente , Desenho de Prótese , Pseudofacia , Refração Ocular , Estudos Retrospectivos
17.
Clin Ophthalmol ; 16: 1613-1621, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35651536

RESUMO

Purpose: Extended depth of focus intraocular (EDOF) IOLs form a bridge between single- and multifocal IOL design. This study aimed to compare clinical outcomes obtained after implanting two different optical designs of EDOF IOLs: the Mini Well Ready (SIFI Medtech, Catania, Italy) and Tecnis Symfony (Abbott Laboratories, Illinois, USA). Methods: The retrospective observational study included 61 patients (122 eyes) who underwent bilateral implantation of the Mini Well Ready IOL (32 patients) or the Tecnis Symfony IOL (29 patients). The following preoperative and postoperative parameters were evaluated: spherical equivalent, anterior astigmatism, pupil size, monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), monocular and binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA). In the 6 months postoperative period, defocus curve, contrast sensitivity, photopic phenomena, and posterior capsule opacification were assessed. Results: The patients receiving the Tecnis Symfony had slightly better monocular and binocular UDVA and CDVA than with the Mini Well Ready IOL, the differences were not statistically significant. Whereas the UIVA, DCIVA, UNVA, DCNVA, UNVA and DCNVA values were higher in the Mini Well Ready group, the differences were not significant. There were no significant between-group differences regarding the defocus curve for the vast majority of tested vergences. Dysphotopsias postoperatively were assessed at 6 months. Conclusion: Patients receiving both the Mini Well Ready and Symfony IOLs had excellent visual acuity outcomes and spectacle independence.

18.
BMC Ophthalmol ; 22(1): 240, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35642049

RESUMO

PURPOSE: To assess the depth of field (DOF) by means of defocus curve analysis applying different visual acuity criteria in patients following cataract surgery and bilateral implantation of a new trifocal diffractive intraocular lens (IOL). METHODS: Fifty eyes of 25 consecutive patients who underwent implantation of the Asqelio™ trifocal IOL (AST Products Inc., USA) were enrolled in this observational prospective study. Monocular subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance for different visual acuities values. Patient's visual satisfaction, postoperative refraction and visual acuity at far, intermediate (67 cm) and near (40 cm) distances were also measured at 1 and 3-months post-surgery. Analysis of variance was used to assess differences in refractive error after the surgical procedure, and paired t-tests were used to assess differences in VA. Patient satisfaction results were reported as percentages. RESULTS: Spherical equivalent was 0.05 ± 0.23 D and residual cylinder 0.01 ± 0.23 D 3-months after the surgery. Absolute DOF obtained was 3.29 ± 0.91 D considering 0.1 LogMAR as cut-off value, and 4.82 ± 0.69 D when 0.3 logMAR as cutoff value. Relative DOF considering a drop of 0.1 logMAR from maximum visual acuity was 2.57 ± 0.82 D, and 1.27 ± 0.70 D when a drop of 0.04 logMAR was considered. Visual acuities obtained 3-months after the surgery were 0.03 ± 0.13, - 0.05 ± 0.06, 0.03 ± 0.08 and 0.04 ± 0.08 logMAR for uncorrected and best-corrected for distance, and best distance-corrected for intermediate and near distances, respectively. Average response to visual satisfaction queries was 8.24/10 at distance, 8.04/10 at intermediate, and 7.88/10 at near. CONCLUSIONS: Patients implanted with this trifocal IOL showed a significant improvement in visual acuity at different distances providing wide absolute and relative DOF values. The outcomes demonstrate that this lens is predictable yielding good patient satisfaction rates.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Desenho de Prótese , Refração Ocular
19.
Eur J Ophthalmol ; 32(6): 3461-3469, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35410507

RESUMO

PURPOSE: This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis® Symfony®, Johnson & Johnson Vision, Santa Ana, CA, USA) and a new presbyopia-correcting IOL that combines EDOF and multifocal profiles (ZFR00; Tecnis® Synergy®, Johnson & Johnson Vision, Santa Ana, CA, USA) with the same material. METHODS: The medical records of patients undergoing cataract surgery with ZXR00 or ZFR00 implantation between March 2021 and July 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA), corrected distance VA, defocus curves, refractive errors (RE), optical quality parameters, and patient-reported visual performance parameters were the main outcome measures. RESULTS: Among the twenty-three enrolled patients, twelve patients (21 eyes) received ZXR00 and nine patients (17 eyes) received ZFR00. The mean age of the patients was 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in ZXR00 and ZFR00 groups, respectively, without significant difference. There was not a significant difference between the two groups in terms of baseline parameters and postoperative RE. The ZFR00 group showed markedly superior intermediate and near VA (p < 0.001 for all) at 3 months postoperatively. In terms of optical quality, ZXR00 was significantly better than ZFR00 (p < 0.001). CONCLUSIONS: Both IOLs had comparable distance VA. ZFR00 IOL was superior for intermediate and near visual acuity, but ZXR00 IOL was better for optical quality. Research with more participants is needed to support this finding.


Assuntos
Extração de Catarata , Lentes Intraoculares , Facoemulsificação , Presbiopia , Erros de Refração , Idoso , Humanos , Implante de Lente Intraocular , Pessoa de Meia-Idade , Satisfação do Paciente , Presbiopia/cirurgia , Desenho de Prótese , Refração Ocular , Acuidade Visual
20.
BMC Ophthalmol ; 22(1): 106, 2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35248018

RESUMO

BACKGROUND: To assess dynamic visual acuity (DVA) under different defocus statuses and explore the assessment of dynamic vision accommodation. METHODS: Twenty subjects (6 males and 14 females) aged 18 to 35 were recruited. Nonmydriatic subjective refraction (sphere and cylinder) and accommodative tests including negative relative accommodation (NRA), positive relative accommodation (PRA), binocular cross cylinder (BCC) and accommodative facility using a flipper were performed. Binocular static visual acuity (SVA) and DVA at 40 degrees per second (dps) were measured under different defocus statuses (+1.5D to -4D in -0.5D steps) based on the refractive error fully corrected. Static and dynamic defocus curves were plotted. The area under the curve (AUC) and corrected dynamic vision accommodation (CDVAc) were calculated. RESULTS: The study showed that the dynamic defocus curve fitted the cubic curve properly (p<0.001). DVA was significantly worse than SVA at all defocused statuses (p<0.001), and the difference was more significant at greater defocus diopters. Single factor analysis indicated that CDVAc was significantly correlated with NRA-PRA (p=0.012) and AUCdynamic (p<0.001). Significant associations were observed between AUCdynamic and PRA (p=0.013) as well as NRA-PRA (p=0.021). Meanwhile, DVA was positively correlated with PRA at 0D, -1.0D, -1.5D, -2.5D and -3.0D (p<0.05) and with NRA-PRA at 0D, -1.0D, -1.5D, -2.0D and -2.5D (p<0.05). Multiple factor regression analysis indicated that CDVAc (0D ~ -3.5D) and SVA (+1.5D ~ +1.0D & -2.5D ~ -4.0D) were significant influential factors for defocused DVA (p<0.05). CONCLUSIONS: Our study demonstrated that DVA had a defocus curve similar to that of SVA. CDVAc was feasible for the assessment of dynamic vision accommodative function. The dynamic defocus curve test could efficiently be applied in the evaluation of dynamic visual performance under different defocus statuses.


Assuntos
Acomodação Ocular , Erros de Refração , Adolescente , Adulto , Feminino , Humanos , Masculino , Erros de Refração/diagnóstico , Testes Visuais , Visão Binocular , Acuidade Visual , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...