Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 17.503
Filtrar
1.
J. optom. (Internet) ; 17(3): [100510], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231872

RESUMO

Purpose: To evaluate the association between visual symptoms and use of digital devices considering the presence of visual dysfunctions. Methods: An optometric examination was conducted in a clinical sample of 346 patients to diagnose any type of visual anomaly. Visual symptoms were collected using the validated SQVD questionnaire. A threshold of 6 hours per day was used to quantify the effects of digital device usage and patients were divided into two groups: under and above of 35 years old. A multivariate logistic regression was employed to investigate the association between digital device use and symptoms, with visual dysfunctions considered as a confounding variable. Crude and the adjusted odds ratio (OR) were calculated for each variable. Results: 57.02 % of the subjects reported visual symptoms, and 65.02% exhibited some form of visual dysfunction. For patients under 35 years old, an association was found between having visual symptoms and digital device use (OR = 2.10, p = 0.01). However, after adjusting for visual dysfunctions, this association disappeared (OR = 1.44, p = 0.27) and the association was instead between symptoms and refractive dysfunction (OR = 6.52, p < 0.001), accommodative (OR = 10.47, p < 0.001), binocular (OR = 6.68, p < 0.001) and accommodative plus binocular dysfunctions (OR = 46.84, p < 0.001). Among patients over 35 years old, no association was found between symptoms and the use of digital devices (OR = 1.27, p = 0.49) but there was an association between symptoms and refractive dysfunction (OR = 3.54, p = 0.001). Conclusions: Visual symptoms are not dependent on the duration of digital device use but rather on the presence of any type of visual dysfunction: refractive, accommodative and/or binocular one, which should be diagnosed.(AU)


Assuntos
Humanos , Masculino , Feminino , Visão Ocular , Testes Visuais , Campos Visuais , Pessoas com Deficiência Visual , Visão Binocular , Inquéritos e Questionários , Optometria
2.
IJU Case Rep ; 7(5): 355-358, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39224684

RESUMO

Introduction: Although uterine perforation is a rare but serious complication, intrauterine devices are globally popular and effective contraceptive methods. Case presentation: A 76-year-old female patient manifesting symptoms of vaginal leakage and lower abdominal discomfort was admitted to our hospital. Diagnostic imaging identified a vesicovaginal fistula and bladder calculi attributable to perforation of the bladder by an intrauterine device that had been inserted over four decades ago. The patient underwent open surgery for cystolith removal and vesicovaginal fistula repair. Conclusions: If a patient with an intrauterine device complains of bladder stones or ongoing lower urinary tract symptoms, bladder perforation caused by the device should be considered in the differential diagnosis.

3.
BMJ Open Respir Res ; 11(1)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39222967

RESUMO

INTRODUCTION: Both physicians and patients are increasingly aware of the environmental impacts of medication. The shift of treatment paradigm towards MART-treatment (Maintenance and Reliever Therapy) in asthma affects the treatment-related emissions. The carbon footprint of inhaled medication is also tied to the type of the device used. Today the most commonly used propellant-containing pressurised metered-dose inhalers (pMDIs) have a carbon footprint typically 20-40-fold higher than propellant-free dry powder inhalers (DPIs) and soft mist inhalers. METHODS: We analysed the carbon footprint of inhaled medications in Europe using published life cycle analyses of marketed inhalers and comprehensive 2020 European sales data. In addition, we give an estimate on treatment-related emissions of different treatment regimens on Global Initiative for Asthma (GINA) step 2. RESULTS: There is potential to reduce the carbon footprint of inhaled medications by 85% if DPIs are preferred over pMDIs. Emissions from pMDIs in the EU were estimated to be 4.0 megatons of carbon dioxide equivalent (MT CO2e) and this could be reduced to 0.6 MT CO2e if DPIs were used instead. In the treatment of moderate asthma with DPI, an as-needed combination of inhaled corticosteroid and long-acting beta-agonist in a single inhaler had a substantially lower annual carbon footprint (0.8 kg CO2e) than the more traditional maintenance therapy with an inhaled corticosteroid alone with as-needed short-acting beta-agonist (2.9 kg CO2e). DISCUSSION: There has been an urgent call for healthcare to reduce its carbon footprint for appropriate patients with asthma and chronic obstructive pulmonary disease (COPD), changing to non-propellant inhalers can reduce the carbon footprint of their treatment by almost 20-fold.


Assuntos
Asma , Pegada de Carbono , Inaladores de Pó Seco , Gases de Efeito Estufa , Inaladores Dosimetrados , Humanos , Asma/tratamento farmacológico , Administração por Inalação , Gases de Efeito Estufa/análise , Europa (Continente) , Antiasmáticos/administração & dosagem
4.
Nano Lett ; 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39225661

RESUMO

The utilization of perovskite materials in flexible optoelectronics is experiencing distinct diversification including X-ray detection applications. Here, we report the oriented alignment of cesium lead bromide (CsPbBr3) single-crystal arrays on flexible polydimethylsiloxane (PDMS) substrates. By precisely confining the crystallization process within spatially delimited precursor droplets, we achieve a well-oriented crystal alignment through the spontaneous rotation of the CsPbBr3 microcuboids. This approach allows for precise control over the microcuboid morphologies by varying the growth temperature. We design flexible X-ray detector arrays by seamlessly integrating CsPbBr3 microcuboids with electrode arrays. The flexible X-ray detector can output a high sensitivity of 1.97 × 105 µC·Gyair-1·cm-2 and a low detection limit of 89 nGyair·s-1 after the surface passivation process. The excellent mechanical properties, outstanding X-ray detection capabilities, and high pixel uniformity are also demonstrated in conformal X-ray imaging of curved surfaces.

5.
Eur Radiol ; 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39225792

RESUMO

Vascular access is the initial, very important, step of endovascular procedures. Various access sites include the common femoral artery, brachial artery, radial artery, popliteal artery, and distal tibial vessels (pedal arteries). Successful arterial access requires advanced knowledge of anatomy, as well as proper training and experience. Today, vascular access should be obtained using real-time, ultrasound guidance to reduce access time, patient discomfort, and puncture-related complications including dissection, arteriovenous communication, and bleeding. Nevertheless, high-level evidence to support this recommendation in peripheral procedures is limited and level A data are mainly derived from randomized cardiac trials investigating only radial and femoral access. Vascular closure devices (VCDs) for femoral access can be broadly categorized as active closure devices, compression assist devices, and external/topical hemostasis devices. There is high-level evidence demonstrating that their use is related to less time for ambulation and increased patient satisfaction. However, available data failed to clearly demonstrate a benefit in complications compared to standard manual compression in peripheral endovascular arterial procedures, and thrombotic and infectious complications reported following VCD use remain an issue. Heterogeneity noted in the literature, caused by the vast variety of devices, access sites, sheath sizes, clinical scenarios, and procedures, poses difficulties in data analysis and future study design. As a result, an individualized VCD use is currently suggested for ≥ 5 Fr femoral artery access not only to reduce time to hemostasis and ambulation and to improve patient comfort, but also to reduce bleeding complications in cases of femoral access with increased bleeding risk, deranged coagulation, and large-bore access, though a high level of evidence to support this later recommendation is limited. KEY POINTS: US guidance is strongly recommended for femoral access and is mandatory to obtain more challenging access. The use of VCDs for femoral hemostasis is generally safe, effective, and currently supported by level I evidence. Proper training and correct VCD choice, based on the patient's individual characteristics, are imperative to optimize outcomes.

6.
BMC Musculoskelet Disord ; 25(1): 697, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39223520

RESUMO

OBJECTIVE: There is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF. METHODS: Based on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing. RESULTS: Under a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS. CONCLUSION: The PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.


Assuntos
Pinos Ortopédicos , Fraturas do Colo Femoral , Análise de Elementos Finitos , Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/fisiopatologia , Fenômenos Biomecânicos/fisiologia , Estresse Mecânico , Suporte de Carga
7.
Diabetes Res Clin Pract ; 217: 111845, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39243866

RESUMO

Diabetic foot care has become a critical focus in global healthcare due to the rising prevalence of diabetes and its associated complications. This review aims to consolidate recent advancements and best practices in managing diabetic foot conditions, encompassing foot ulcers, neuropathy, vascular disease, and the risk of amputation. Emphasizing a multidisciplinary approach, the review advocates for collaboration among diabetologists, podiatrists, vascular surgeons, and wound care specialists to enhance patient outcomes. Key advancements highlighted include innovative wound care techniques like advanced dressings and bioengineered skin substitutes, alongside effective offloading devices to prevent pressure-related injuries. Early detection and intervention strategies for neuropathy and vascular disease are underscored, with a particular focus on vascular evaluation as a baseline investigation, including Ankle-Brachial Index (ABI) and Toe-Brachial Index (TBI) assessments by trained podiatrists and the use of arterial color Doppler/duplex scans for suspected Peripheral Artery Disease (PAD). The review also examines the impact of technological innovations such as telemedicine and wearable devices, facilitating enhanced patient monitoring and timely interventions. It stresses the importance of patient education and self-care practices in mitigating complications. Addressing global disparities, the review advocates for accessible and equitable healthcare services across diverse regions. Concluding with recommendations for future research and policy initiatives, this review serves as a vital resource for healthcare professionals, policymakers, and researchers committed to advancing diabetic foot care and improving global patient outcomes.

8.
Health Policy ; 149: 105152, 2024 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-39244818

RESUMO

In August 2024, the EU Artificial Intelligence Act (AI Act) entered into force. This legally binding instrument sets rules for the development, the placing on the market, the putting into service, and the use of AI systems in the European Union. As the world's first extensive legal framework on AI, it aims to boost innovation while protecting individuals against the harms of AI. Since healthcare is one of the top sectors for AI deployment, the new rules will significantly reform national policies and practices on health technology. In this article, we highlight the implications of the AI Act for the healthcare sector. We give a comprehensive overview of the new legal obligations for various healthcare stakeholders (tech developers; healthcare professionals; public health authorities). We conclude that, due to its horizontal approach, it is necessary to adopt further guidelines to address the unique needs of the healthcare sector. To this end, we make recommendations for the upcoming implementation and standardization phase.

9.
J Chromatogr A ; 1735: 465323, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39244911

RESUMO

Plastic additives are introduced in plastic material formulations, along with organic polymers, to offer different properties such as stability, plasticity or color. However, plastic additives may migrate from the plastic material to the content (in case of plastic containers) or to the material in contact with the plastic, like human skin. In the case of plastic medical devices, this migration is of particular interest, as plastic additives may be deleterious to health. In the present paper, we examined the interest of combining supercritical fluid extraction (SFE) to supercritical fluid chromatography (SFC) hyphenated to mass spectrometry (MS) in an online system to characterize plastic additives in laboratory gloves, taken as samples of medical devices. A set of target compounds comprising 18 plasticizers, 4 antioxidants and 2 lubricants was defined and their detectability with MS was examined, where it appeared that electrospray ionization (ESI) provided better detectability than atmospheric pressure chemical ionization (APCI). After examining possible stationary phases with the help of Derringer desirability function, an isocratic chromatographic method (CO2:methanol 95:5) was developed on Shim-pack UC Phenyl column. The extraction method was examined with a 3-level full factorial design of experiments to optimize the extraction temperature (40 °C) and pressure (200 bar). The online SFE-SFC-MS method was compared to offline methods where the samples were extracted with liquid solvents at atmospheric pressure or high pressure then analysed with SFC-MS. In all cases, offline methods showed significant contaminants (like the oleamide lubricant) issuing from laboratory plastic materials as nitrogen drying station, syringes and filters, while the online method allowed a complete elimination of laboratory contaminations. Furthermore, the online method saved time, solvents and laboratory consumables. It will also show that transferring a compressible fluid from a loading loop is favourable to high efficiency, as the resulting chromatographic peaks are much thinner than when transferring a liquid. Compared to injecting liquid heptane, the efficiency increase was 3.4-fold, while compared to injecting liquid methanol (a common practice in SFC), the efficiency increase was 13-fold. Finally, the additive composition of different laboratory gloves was compared.

10.
World J Pediatr Congenit Heart Surg ; : 21501351241269942, 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39246213

RESUMO

The 18th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion was held in Milwaukee, WI, USA, on May 9 and 10, 2024. The conference was hosted by the Herma Heart Institute of Children's Wisconsin at the Pfister Hotel in downtown Milwaukee. This communication provides the highlights of the proceedings.

11.
Artigo em Inglês | MEDLINE | ID: mdl-39221579

RESUMO

In the vanguard of neuromorphic engineering, we develop a paradigm of biocompatible polymer memcapacitors using a seamless solution process, unleashing comprehensive synaptic capabilities depending on both the stimulation form and history. Like the human brain to learn and adapt, the memcapacitors exhibit analogue-type and evolvable capacitance shifts that mirror the complex flexibility of synaptic strengthening and weakening. With increasing frequency and intensity of the stimulation, the memcapacitors demonstrate an evolution from short-term plasticity (STP) to long-term plasticity (LTP), and even to metaplasticity (MP) at a higher level. A physical picture, featuring the stimulus-controlled spatiotemporal ion redistribution in the polymer, elaborates the origin of the memcapacitive prowess and resultant versatile synaptic plasticity. The distinctive MP behavior endows the memcapacitors with a dynamic learning rate (LR), which is utilized in an artificial neural network. The superiority of implementing a dynamic LR compared with conventional practices of using constant LR shines light on the potential of the memcapacitors to exploit organic neuromorphic computing hardware.

12.
Heliyon ; 10(16): e35620, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39220921

RESUMO

As urban populations grow, it's imperative to evaluate and enhance the quality of pedestrian paths from the user's perspective. Crowdedness, associated with discomfort and safety, is crucial in determining the overall walking quality and user experience. Previously utilized methods for measuring crowdedness, such as travel diaries and floating population surveys, were limited to collecting perceptual data from sporadic surveys with restricted spatial coverage. Similarly, methods based on CCTV or mobile service data have been used but present issues with blind spots and fail to consider pedestrian perspectives. Against this background, this study explores the feasibility of assessing crowdedness levels by measuring subjects' physiological responses in a laboratory setting based on visual images of real and virtual environments. This study hypothesizes that the amount of people or vehicles passing by affects the electrodermal activity (EDA) of pedestrians, indicating the comfort level of using the environment. Experimental EDA data were measured using a wearable device while the subjects were watching videos showing different pedestrian traffic flows. Representative EDA signal features (e.g., skin conductance responses) were extracted after data pre-processing. Noticeable changes in EDA responses are observed when subjects countered specific environmental variations, such as differing volumes of passing people, on pedestrian paths. The findings suggest that EDA data can be instrumental in differentiating crowdedness levels on pedestrian paths. This study contributes to the body of knowledge by demonstrating the potential of EDA data to characterize the crowdedness experienced by pedestrians. This aids in the development of a novel, quantitative method to gauge pedestrian path crowdedness and to discern contributing factors, such as path width.

13.
Cureus ; 16(8): e65915, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39221311

RESUMO

Aim The objective of this study is to evaluate the feasibility of using iliac branch endoprosthesis (IBE) devices and to examine their short-term outcomes. Materials and methods This was a descriptive, retrospective observational study involving 15 patients diagnosed with either aortoiliac or isolated iliac artery aneurysms and treated with an IBE device. Data were collected for patients who received IBE devices at Glan Clwyd Hospital in Rhyl, United Kingdom, from February 2020 to May 2023. Results Most patients presented with asymptomatic aneurysms; 86.7% (n = 13) had bilateral common iliac artery (CIA) aneurysms. The mean diameter of the CIA was 38.7 ± 8.8 mm, and the mean diameter of the abdominal aortic aneurysm (AAA) was 39.8 ± 23 mm. For the indications of IBE use, 60% (n = 9) of the patients had iliac aneurysms reaching the intervention threshold, 20% (n = 3) had AAA reaching the threshold, and 20% (n = 3) had aortoiliac aneurysms reaching the threshold. The majority of patients underwent bilateral femoral access (86.7%; n = 13), while 13.3% (n = 2) required both femoral and brachial access. Technical success was achieved in all cases. Aside from 20% (n = 3) of cases where the sac size remained static, the majority of patients (80%; n = 12) experienced sac regression. All patients were free from buttock claudication. A type II endoleak was observed in 33.3% (n = 5) of patients. No reinterventions were reported. The mean primary patency was 30.9 ± 0.7 months, and the follow-up period ranged from 12 to 36 months. Conclusions IBEs are an effective medical device, demonstrating a high rate of technical success, minimal need for additional procedures, and a low incidence of complications while maintaining a satisfactory rate of primary patency.

14.
Cureus ; 16(8): e65920, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39221386

RESUMO

Aim School nurses often use diabetes mellitus devices as part of the care provided to students with Type 1 Diabetes Mellitus. The aim of this study was to explore the psychometric properties of the Greek version of the Diabetes Devices Confidence Scale (DDCS). Methods In this cross-sectional, descriptive study, 143 school nurses completed the DDCS. This is a self-administered questionnaire exploring the nurses' confidence in the use of diabetes devices. The scale was translated and culturally adapted according to the WHO guidelines. The Intraclass Correlation Coefficient and Cronbach's Alpha Index were used to explore the reliability and internal consistency, respectively. The construct validity was tested via exploratory and confirmatory factor analysis (EFA, CFA). Data were analyzed via Statistical Package for the Social Sciences (SPSS), version 22.0 (IBM Corp., Armonk, NY, USA). Results Significant correlations were observed between the two administrations (p<0.001) indicating the good reliability of the scale (ICC = 0525, p<0.001) while Cronbach's Alpha was 0.966 suggesting excellent internal consistency. The EFA resulted in a unidimensional solution explaining 53.7% of the total variance. The CFA showed that the model presents good fit to the data. Conclusions The DDCS is a reliable and valid tool to test the nurses' confidence in diabetes devices.

15.
JMIR Form Res ; 8: e56962, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39221852

RESUMO

BACKGROUND: The number of individuals using digital health devices has grown in recent years. A higher rate of use in patients suggests that primary care providers (PCPs) may be able to leverage these tools to effectively guide and monitor physical activity (PA) for their patients. Despite evidence that remote patient monitoring (RPM) may enhance obesity interventions, few primary care practices have implemented programs that use commercial digital health tools to promote health or reduce complications of the disease. OBJECTIVE: This formative study aimed to assess the perceptions, needs, and challenges of implementation of an electronic health record (EHR)-integrated RPM program using wearable devices to promote patient PA at a large urban primary care practice to prepare for future intervention. METHODS: Our team identified existing workflows to upload wearable data to the EHR (Epic Systems), which included direct Fitbit (Google) integration that allowed for patient PA data to be uploaded to the EHR. We identified pictorial job aids describing the clinical workflow to PCPs. We then performed semistructured interviews with PCPs (n=10) and patients with obesity (n=8) at a large urban primary care clinic regarding their preferences and barriers to the program. We presented previously developed pictorial aids with instructions for (1) providers to complete an order set, set step-count goals, and receive feedback and (2) patients to set up their wearable devices and connect them to their patient portal account. We used rapid qualitative analysis during and after the interviews to code and develop key themes for both patients and providers that addressed our research objective. RESULTS: In total, 3 themes were identified from provider interviews: (1) providers' knowledge of PA prescription is focused on general guidelines with limited knowledge on how to tailor guidance to patients, (2) providers were open to receiving PA data but were worried about being overburdened by additional patient data, and (3) providers were concerned about patients being able to equitably access and participate in digital health interventions. In addition, 3 themes were also identified from patient interviews: (1) patients received limited or nonspecific guidance regarding PA from providers and other resources, (2) patients want to share exercise metrics with the health care team and receive tailored PA guidance at regular intervals, and (3) patients need written resources to support setting up an RPM program with access to live assistance on an as-needed basis. CONCLUSIONS: Implementation of an EHR-based RPM program and associated workflow is acceptable to PCPs and patients but will require attention to provider concerns of added burdensome patient data and patient concerns of receiving tailored PA guidance. Our ongoing work will pilot the RPM program and evaluate feasibility and acceptability within a primary care setting.


Assuntos
Registros Eletrônicos de Saúde , Exercício Físico , Obesidade , Pesquisa Qualitativa , Dispositivos Eletrônicos Vestíveis , Humanos , Exercício Físico/psicologia , Masculino , Feminino , Obesidade/terapia , Adulto , Pessoa de Meia-Idade , Atenção Primária à Saúde
16.
Bioelectron Med ; 10(1): 21, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39218887

RESUMO

Nearly all geriatric surgical complications are studied in the context of a single organ system, e.g., cardiac complications and the heart; delirium and the brain; infections and the immune system. Yet, we know that advanced age, physiological stress, and infection all increase sympathetic and decrease parasympathetic nervous system function. Parasympathetic function is mediated through the vagus nerve, which connects the heart, brain, and immune system to form, what we have termed, the brain-heart-immune axis. We hypothesize that this brain-heart-immune axis plays a critical role in surgical recovery among older adults. In particular, we hypothesize that the brain-heart-immune axis plays a critical role in the most common surgical complication among older adults: postoperative delirium. Further, we present heart rate variability as a measure that may eventually become a multi-system vital sign evaluating brain-heart-immune axis function. Finally, we suggest the brain-heart-immune axis as a potential interventional target for bio-electronic neuro-immune modulation to enhance resilient surgical recovery among older adults.

17.
Artigo em Inglês | MEDLINE | ID: mdl-39238144

RESUMO

Ionic gels are emerging as a promising solution for improving the functionality of electrochromic devices. They are increasingly drawing attention in the fields of electrochemistry and functional materials due to their potential to address issues associated with traditional liquid electrolytes, such as volatility, toxicity, and leakage. In extreme scenarios and/or the design of flexible devices, ionic gel electrolytes offer unique and invaluable advantages. This perspective delves into the application of ionic gels in electrochromic devices, exploring various methods to enhance their performance. After briefly introducing developments in ionic gels for electrochromic devices, the trends and key points of future development are discussed in detail.

18.
Int J Artif Organs ; : 3913988241268067, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238170

RESUMO

Medical advancements, particularly in ventricular assist devices (VADs), have notably advanced heart failure (HF) treatment, improving patient outcomes. However, challenges such as adverse events (strokes, bleeding and thrombosis) persist. Computational fluid dynamics (CFD) simulations are instrumental in understanding VAD flow dynamics and the associated flow-induced adverse events resulting from non-physiological flow conditions in the VAD.This study aims to validate critical CFD simulation parameters for accurate VAD simulations interacting with the cardiovascular system, building upon the groundwork laid by Hahne et al. A bidirectional coupling technique was used to model dynamic (pulsatile) flow conditions of the VAD CFD interacting with the cardiovascular system. Mesh size, time steps and simulation method (URANS, LES) were systematically varied to evaluate their impact on the dynamic pump performance (dynamic H-Q curve) of the HeartMate 3, aiming to find the optimal simulation configuration for accurately reproduce the dynamic H-Q curve. The new Overlapping Ratio (OR) method was developed and applied to quantify dynamic H-Q curves.In particular, mesh and time step sizes were found to have the greatest influence on the calculated pump performance. Therefore, small time steps and large mesh sizes are recommended to obtain accurate dynamic H-Q curves. On the other hand, the influence of the simulation method was not significant in this study. This study contributes to advancing VAD simulations, ultimately enhancing clinical efficacy and patient outcomes.

19.
Cureus ; 16(8): e66259, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39238676

RESUMO

Dilated cardiomyopathy (DCM) is a prevalent heart muscle disease characterized by ventricular dilation and systolic dysfunction, leading to severe heart failure (HF) and often requiring heart transplantation (HTx). This systematic review aimed to synthesize information regarding the role of ventricular assist devices (VADs) in managing HF patients due to DCM. A comprehensive search was conducted across PubMed, Embase, Scopus, Web of Science, and Cochrane databases for studies published between 2014 and 2024. Inclusion criteria were studies involving adult patients with HF due to DCM treated with VADs. Exclusion criteria included non-human studies, pediatric populations, and non-peer-reviewed articles. Thirty-one studies met the inclusion criteria. The included studies demonstrated that the use of VADs in patients with DCM resulted in significant improvements in left ventricular ejection fraction (LVEF), myocardial fibrosis reduction, and reverse ventricular remodeling. Studies reported enhanced survival rates, reduced symptoms, and better quality of life. VADs served as a critical bridge to HTx and, in some cases, as long-term destination therapy. However, complications such as thrombus formation, anemia, and kidney failure were noted, emphasizing the need for vigilant monitoring and management. Continuous advancements in VAD technology and patient management protocols were found to be essential for optimizing outcomes. We conclude that VADs play a crucial role in managing advanced HF due to DCM by providing mechanical circulatory support, improving cardiac function, and enhancing patient survival and quality of life. Despite associated complications, VADs are invaluable for patients with severe HF, offering both immediate and long-term therapeutic benefits. Future research should focus on minimizing complications and further improving VAD technology to enhance patient outcomes.

20.
Rev Bras Ortop (Sao Paulo) ; 59(4): e613-e616, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39239580

RESUMO

Objective This study aimed to identify the main difficulties faced by the family when a child with congenital clubfoot (CC) uses the Dennis-Brown orthosis. Method This study interviewed via Google Forms caregivers of children treated from 2015 to 2018 regarding their difficulties in orthosis use. Results The answers revealed that orthosis-related difficulties are independent of the child's gender, age, or affected side. We noted that 41.7% of the respondents reported some difficulty, especially the child's irritation when using the orthosis (93.3%). Conclusion The main factor in CC relapses is poor adherence to orthosis use. As a result, studying factors causing or increasing the probability of interrupting orthosis use is significant in creating strategies to facilitate their use, potentially reducing CC recurrence.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA