Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Lab Anim ; : 236772241262119, 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39364664

RESUMO

Isoflurane anesthesia prior to carbon dioxide euthanasia is recognized as a refinement by many guidelines. Facilities lacking access to a vaporizer can use the "drop" method, whereby liquid anesthetic is introduced into an induction chamber. Knowing the least aversive concentration of isoflurane is critical. Previous work has demonstrated that isoflurane administered with the drop method at a concentration of 5% is aversive to mice. Other work has shown that lower concentrations (1.7% to 3.7%) of isoflurane can be used to anesthetize mice with the drop method, but aversion to these concentrations has not been tested. We assessed aversion to these lower isoflurane concentrations administered with the drop method, using a conditioned place aversion (CPA) paradigm. Female C57BL/6J (OT-1) mice (n = 28) were randomly allocated to one of three isoflurane concentrations: 1.7%, 2.7%, and 3.7%. Mice were acclimated to a light-dark apparatus. Prior to and following dark (+ isoflurane) and light chamber conditioning sessions, mice underwent an initial and final preference assessment; the change in the duration spent within the dark chamber between the initial and final preference tests was used to calculate a CPA score. Aversion increased with increasing isoflurane concentration: from 1.7% to 2.7% to 3.7% isoflurane, mean ± SE CPA score decreased from 19.6 ± 20.1 s to -25.6 ± 23.2 s, to -116.9 ± 30.6 s (F1,54 = 15.4, p < 0.001). Our results suggest that, when using the drop method to administer isoflurane, concentrations between 1.7% and 2.7% can be used to minimize female mouse aversion to induction.

2.
Stem Cell Res Ther ; 15(1): 311, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39294780

RESUMO

BACKGROUND: Mesenchymal stem cells (MSCs) have shown a positive effect on Osteoarthritis (OA), but the efficacy is still not significant in clinical. Conventional two-dimensional (2D) monolayer culture method is prone to cause MSCs undergoing replication senescence, which may affect the functions of MSCs. Three-dimensional (3D) culture strategy can sustain cell proliferative capacity and multi-differentiation potential. This study aimed to investigate the therapeutic potential of human umbilical cord-derived mesenchymal stem cells (hUC-MSCs) cultured by 3D hanging drop method on OA. METHODS: hUC-MSCs were isolated from umbilical cord and cultured by 3D hanging drop method for 48 h. Scanning electron microscopy (SEM) was used to observe gross morphology 2D and 3D hUC-MSCs. Transcriptome comparison of gene expression differences between 2D and 3D hUC-MSCs. GO enrichment analysis, KEGG pathway enrichment analysis and GSEA enrichment analysis were used to analyze the impact of 3D hanging drop culture on the biological functions of hUC-MSCs. Female New Zealand rabbits (n = 12) were divided into 4 groups: Normal group, Model group, 2D hUC-MSCs treatment group and 3D hUC-MSCs treatment group. After 8 weeks, the gross and histological appearance of the cartilage was evaluated by safranin O-fast green staining and Mankin scoring system. The expression of type I collagen and type II collagen was detected by immunohistochemistry. The levels of IL-6, IL-7, TNFα, TGFß1 and IL-10 in the knee joint fluid were tested by ELISA. RESULTS: 3D hanging drop culture changed cell morphology but did not affect phenotype. The MSCs transcriptome profiles showed that 3D hanging drop culture method enhanced cell-cell contact, improved cell responsiveness to external stimuli and immunomodulatory function. The animal experiment results showed that hUC-MSCs could promote cartilage regeneration compared with Model group. 3D hUC-MSCs treatment group had a higher histological score and significantly increased type II collagen secretion. In addition, 3D hUC-MSCs treatment group increased the expression of anti-inflammatory factors TGFß1 and IL-10. CONCLUSION: The above experimental results illustrated that 3D hanging drop culture method could enhance the therapeutic effect of hUC-MSCs, and showed a good clinical application prospect in the treatment of OA.


Assuntos
Células-Tronco Mesenquimais , Osteoartrite , Cordão Umbilical , Animais , Coelhos , Células-Tronco Mesenquimais/metabolismo , Células-Tronco Mesenquimais/citologia , Humanos , Cordão Umbilical/citologia , Osteoartrite/terapia , Osteoartrite/patologia , Osteoartrite/metabolismo , Feminino , Transplante de Células-Tronco Mesenquimais/métodos , Diferenciação Celular , Células Cultivadas , Técnicas de Cultura de Células em Três Dimensões/métodos , Proliferação de Células
3.
Methods Mol Biol ; 2777: 135-144, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38478341

RESUMO

Prostate cancer (PCa) is the second most common malignancy and the fifth leading cause of cancer death in men worldwide. Despite its prevalence, the highly heterogenic PCa has shown difficulty to establish representative cell lines that reflect the diverse phenotypes and different stages of the disease in vitro and hence hard to model in preclinical research. The patient-derived organoid (PDO) technique has emerged as a groundbreaking three-dimensional (3D) tumor modeling platform in cancer research. This versatile assay relies on the unique ability of cancer stem cells (CSCs) to self-organize and differentiate into organ-like mini structures. The PDO culture system allows for the long-term maintenance of cancer cells derived from patient tumor tissues. Moreover, it recapitulates the parental tumor features and serves as a superior preclinical model for in vitro tumor representation and personalized drug screening. Henceforth, PDOs hold great promise in precision medicine for cancer. Herein, we describe the detailed protocol to establish and propagate organoids derived from isolated cell suspensions of PCa patient tissues or cell lines using the 3D semisolid Matrigel™-based hanging-drop method. In addition, we highlight the relevance of PDOs as a tool for evaluating drug efficacy and predicting tumor response in PCa patients.


Assuntos
Detecção Precoce de Câncer , Neoplasias da Próstata , Masculino , Humanos , Avaliação Pré-Clínica de Medicamentos/métodos , Neoplasias da Próstata/patologia , Organoides
4.
Chinese Journal of Zoonoses ; (12): 21-25, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1024885

RESUMO

The growth of three plague phages from Qinghai Plateau in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,PTB5,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were detected through a micromethod based on the OmniLogTM microbial identification system and by the drop method,to provide a scientific basis for future ecological studies and classification based on the host range.For plague vaccine strains EV76 and 614F,successful phage infection and subsequent phage growth were observed in the host bacte-rium.Diminished bacterial growth and respiration and a concomitant decrease in color were observed with the OmniLogTM mi-crobial identification system at 33 ℃ for 48 h.Yersinia pseudotuberculosis PTB5 was sensitive to Yersinia pestis phage 476,but Yersinia pseudotuberculosis PST5 was insensitive to phage 087 and 072204.Three strains of non-Yersinia pestis(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersinia enterocolitica 52302-2)were insensitive to Yersinia pestis pha-ges 087,072204,and 476 showed similar growth curves.The growth of phages 476 and 087,as determined with the drop method,in two Yersinia pestis strains(plague vaccine strains EV76 and 614F)and four non-Yersinia pestis strains(Yersinia pseudotuberculosis PTB3,Escherichia coli V517,and Yersin-ia enterocolitica 52302-2)showed the same results at 37 ℃,on the basis of comparisons with the OmniLogTM microbial i-dentification system;in contrast,phages 072204 did not show plaques on solid medium at 37 ℃ with plague vaccine strains EV76 and 614F.Determination based on the OmniLogTM detection system can be used as an alternative to the traditional determination of the host range,thus providing favorable application val-ue for determining the interaction between the phage and host bacteria.

5.
Food Sci Nutr ; 11(5): 2243-2253, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37181302

RESUMO

The main purpose of this study was to evaluate the effects of the cushion box and closed let-down ladder usage in minimizing mechanical damage to corn kernels during free fall. Kernels from a single lot of cultivar KSC 705 were evaluated for percentage of breakage using three drop methods (free fall, with cushion box, and with closed let-down ladder) at five different moisture contents (10%, 15%, 20%, 25%, and 30%), and three drop heights (5, 10, and 15 m). The results showed that the drop methods had a significant effect on the breakage sensibility of kernels. Sample kernels dropped without a ladder (free fall) had a significantly higher average percentage breakage of 13.80%. In the use of the cushion box, the average kernel breakage was calculated to be 11.41%, which was decreased by about 17% more than the free fall. Sample kernels dropped with the closed let-down ladder had a lower average breakage of 7.26%, which showed that the closed let-down ladder significantly helped to reduce mechanical damage to corn kernels by about 47% comparing free fall and by about 37% than the use of the cushion box. The amounts of kernel damage increased significantly with increasing drop height and decreasing moisture content, but the use of the cushion box and closed let-down ladder systems somewhat reduced the adverse effect of the above factors. To minimize mechanical damage to kernels as they fall into the bin, a grain let-down ladder should be installed in the bin so that it can receive kernels from the filling spout with minimum damage. Empirical models were developed for the dependency of damage to corn kernels due to the impact caused by free fall on the drop height and moisture content at different drop methods.

6.
Materials (Basel) ; 15(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36556831

RESUMO

The wetting behavior of liquid magnesium drop on pure tungsten substrates was investigated, for the first time, with the sessile drop method combined with non-contact heating and capillary purification of a Mg drop from a native oxide film. A specially designed apparatus dedicated to the investigation of the high-temperature interaction of dissimilar materials was used. The comparative experiments were performed under isothermal conditions at temperatures of 700 °C and 740 °C using two atmospheres: Ar + 5 wt.% H2 and pure Ar, respectively. During high-temperature tests for 180 s, the images of the Mg/W couples were recorded with CCD cameras (57 fps) from two directions of observation. The solidified drop/substrate couples were subjected to structural characterization using scanning electron microscopy (SEM) coupled with energy-dispersive X-ray spectroscopy (EDS). Under the applied measurement conditions, liquid Mg revealed non-wetting behavior on W substrates (a contact angle θ > 90°). The average value of the contact angle under the flowing Ar atmosphere at 740 °C was θav = 115°, whereas it was higher under the flowing Ar + 5 wt.%. H2 atmosphere at a lower temperature of 700 °C, showing θav = 122°. Independently on employed atmosphere and temperature, SEM + EDS analysis of solidified sessile drop couples did not display any new phases and mass transfer between the Mg drop and the W substrate, whereas the presence of discontinuities at the Mg/W interface of cross-sectioned couples were well-distinguished. Non-wetting and a lack of permanent bonding between the Mg drop and W substrates have a good agreement with the Mg−W phase diagram calculated with the help of FactSage software and FTlite database, i.e., the non-reactive nature of the Mg/W couple because W does not dissolve in liquid Mg and it does not form any compounds with Mg. These findings allow for the recommendation of tungsten as a suitable refractory material for long-time contact with liquid Mg in different container-assisted methods of materials characterization as well as in liquid-assisted processing of Mg components.

7.
Plant Methods ; 18(1): 142, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36550504

RESUMO

BACKGROUND: Corn seeds have a high susceptibility to mechanical damage due to their large size and mass. The main purpose of this study was to evaluate the effects of the cushion box and closed let-down ladder usage in minimizing the negative influence of the free fall on the storage potential of corn seeds. Corn seeds were evaluated for the extent of physiological damage by measuring the seed deterioration by the accelerated aging test (percentage loss in germination in the accelerated aging test), using three drop methods (free fall, with cushion box, and with closed let-down ladder) at three drop heights (5, 10, and 15 m) and five different moisture contents (10, 15, 20 and 25%). RESULTS: The drop methods had a significant effect on the storage potential of corn seeds. Sample seeds dropped without a ladder (free fall) had a significantly higher average physiological quality loss of 13.87% (loss in accelerated aging germination). In the use of the cushion box, the average percentage loss in germination was calculated to be 11.38%, which was decreased by about 18% more than the free fall. Sample seeds dropped with the closed let-down ladder had a lower average percentage loss in the germination of 8.78%, which showed that the closed let-down ladder significantly helped to reduce mechanical damage to corn seeds by about 37% comparing free fall and by about 23% to the use of the cushion box. The amounts of loss in physiological quality of corn seeds increased significantly with increasing drop height and moisture content, but the use of the cushion box and closed let-down ladder systems somewhat reduced the adverse effect of the above factors. Empirical models were developed for the dependency of physiological damage to corn seeds due to the impact caused by free fall, on the drop height and moisture content at different drop methods. CONCLUSIONS: To minimize mechanical damage to seeds as they fall into the bin, a let-down ladder should be installed in the bin so that it can receive seeds from the filling spout with minimum damage.

8.
ACS Appl Bio Mater ; 5(12): 5582-5594, 2022 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-36445173

RESUMO

Multicellular tumor spheroids are the most well-characterized organotypic models for cancer research. Generally, scaffold-based and scaffold-free techniques are widely used for culturing spheroids. In scaffold-free techniques, the hanging drop (HD) method is a more versatile technique, but the retrieval of three-dimensional (3D) cell spheroids in the hanging drop method is usually labor-intensive. We developed oil-coated polystyrene nanofiber-based reusable slippery surfaces for the generation and easy retrieval of 3D spheroids. The developed slippery surfaces facilitated the rolling and gliding of the cell medium drops as well as holding the hydrophilic drops for more than 72 h by the virtue of surface tension as in the hanging drop method. In this study, polystyrene nanofibers were developed by the facile technique of electrospinning and the morphological evaluation was performed by scanning electron microscopy (SEM) and cryo-FESEM. We modeled the retrieval process of 3D spheroids with the ingredients of 3D spheroid generation, such as water, cell culture media, collagen, and hyaluronic acid solution, demonstrating the faster and easy retrieval of 3D spheroids within a few seconds. We created MCF-7 spheroids as a proof of concept with a developed slippery surface. 3D spheroids were characterized for their size, homogeneity, reactive oxygen species, proliferative marker (Ki-67), and hypoxic inducing factor 1ά (HIF-1ά). These 3D tumor spheroids were further tested for evaluating the cellular toxicity of the doxorubicin drug. Hence, the proposed slippery surfaces demonstrated the potential alternative of culturing 3D tumor spheroids with an easy retrieval process with intact 3D spheroids.


Assuntos
Neoplasias , Poliestirenos , Humanos , Técnicas de Cultura de Células/métodos , Esferoides Celulares , Colágeno
9.
Curr Protoc ; 2(10): e569, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36286844

RESUMO

When compared to two-dimensional (2D) cell cultures, 3D spheroids have been considered suitable in vitro models for drug discovery research and other studies of drug activity. Based on different 3D cell culture procedures, we describe procedures we have used to obtain 3D tumor spheroids by both the hanging-drop and ultra-low-attachment plate methods and to analyze the antiproliferative and antitumor efficacy of different chemotherapeutic agents, including a peptidomimetic. We have applied this method to breast and lung cancer cell lines such as BT-474, MCF-7, A549, and Calu-3. We also describe a proximity ligation assay of the cells from the spheroid model to detect protein-protein interactions of EGFR and HER2. © 2022 Wiley Periodicals LLC. Basic Protocol 1: Growth of 3D spheroids using the hanging-drop method Basic Protocol 2: Growth of spheroids using ultra-low-attachment plates Support Protocol 1: Cell viability assay of tumor spheroids Support Protocol 2: Antiproliferative and antitumor study in 3D tumor spheroids Support Protocol 3: Proximity ligation assay on cells derived from 3D spheroids.


Assuntos
Neoplasias Pulmonares , Peptidomiméticos , Humanos , Esferoides Celulares , Técnicas de Cultura de Células/métodos , Neoplasias Pulmonares/tratamento farmacológico , Receptores ErbB
10.
Membranes (Basel) ; 12(8)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36005679

RESUMO

The contact angle between a membrane surface and a waterdrop lying on its surface provides important information about the hydrophilicity/hydrophobicity of the membrane. This method is well-developed for solid non-swelling materials. However, ion-exchange membranes (IEMs) are gel-like solids that swell in liquids. When an IEM is exposed to air, its degree of swelling changes rapidly, making it difficult to measure the contact angle. In this paper, we examine the known experience of measuring contact angles and suggest a simple equipment that allows the membrane to remain swollen during measurements. An optimized protocol makes it possible to obtain reliable and reproducible results. Measuring parameters such as drop size, water dosing speed and others are optimized. Contact angle measurements are shown for a large number of commercial membranes. These data are supplemented with values from other surface characteristics from optical and profilometric measurements.

11.
J Anesth ; 36(3): 441-443, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35391581

RESUMO

A drop of saline placed within the hub of an epidural needle is sucked in when the needle is advanced and penetrates through a polyurethane foam cube. This phenomenon might be explained by the release of compressed air inside of the needle into the air. The positive pressure inside of the needle may be generated by advancing of the needle. To prove this hypothesis, the pressure inside of the needle was measured during needle advancement, and it increased gradually and then dropped to zero suddenly when the needle fully penetrated the polyurethane foam block. We can speculate that the same phenomenon occurs during hanging-drop method of epidural anesthesia, and this may occur regardless of whether epidural subatmospheric pressure exists or not.


Assuntos
Anestesia Epidural , Anestesia Epidural/métodos , Espaço Epidural , Agulhas , Poliuretanos , Seringas
12.
Methods Mol Biol ; 2520: 37-51, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34128207

RESUMO

Induced pluripotent stem (iPS) cells are genetically reprogrammed somatic cells that exhibit embryonic stem cell-like characteristics such as self-renewal and pluripotency. These cells have broad differentiation capability to convert into diverse cell types that make up the primary germ layers during embryonic development. iPS cells can spontaneously differentiate and form cell aggregates termed embryoid bodies (EBs) in the absence of differentiation inhibitory factors. Unlike other methods used to generate EBs, "the hanging drop" method offers reproducibility and homogeneity from a set number of iPS cells. As such, we describe the differentiation of rat-induced pluripotent stem cells into cardiac myocytes in vitro using the hanging drop method. Both the confirmation and identification of the cardiac myocytes are done using immunocytochemistry, RT-PCR, Western Blot, and Flow Cytometry. Briefly, a specific number of iPS cells are placed in droplets on the lid of culture dishes and incubated for 2 days, yielding embryoid bodies, which are suspended and plated. Spontaneous beating of cardiomyocytes can be seen 7-14 days after the plating of EBs and specific cardiac markers can be observed through identification assays.


Assuntos
Células-Tronco Pluripotentes Induzidas , Animais , Técnicas de Cultura de Células/métodos , Diferenciação Celular , Corpos Embrioides , Miócitos Cardíacos , Ratos , Reprodutibilidade dos Testes
13.
Sensors (Basel) ; 21(21)2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34770642

RESUMO

Automobile laser brazing remains a complex process whose results are affected by several process variables that may result in nonacceptable welds. A multisensory customized inspection system is proposed, with two distinct non-destructive techniques: the potential drop method and eddy current testing. New probes were designed, simulated, produced, and experimentally validated in automobile's laser-brazed weld beads with artificially introduced defects. The numerical simulations allowed the development of a new four-point probe configuration in a non-conventional orthogonal shape demonstrating a superior performance in both simulation and experimental validation. The dedicated inspection system allowed the detection of porosities, cracks, and lack of bonding defects, demonstrating the redundancy and complementarity these two techniques provide.

14.
Nanomaterials (Basel) ; 11(6)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34205939

RESUMO

Understanding the atomic-level phenomena occurring upon the wetting of graphene-coated Cu with liquid Ag is pivotal for the description of the wetting phenomenon and the role of graphene as a diffusion barrier. We have performed molecular dynamics (MD) simulations and confronted with our present experimental results to characterize wetting behavior of graphene coated Cu surfaces. Perfect and defected graphene layers covering Cu surface were wetted with liquid Ag droplet at 1273 K. Structural and topological aspects are discussed to characterize structure of the liquid Ag droplet and a product of wetting reaction occurring on Cu/Gn and Cu/Gndef substrates, also including perfect graphene layer and a pure Cu surface. The obtained results reveal the importance of defects in graphene structure, which play a key role in wetting mechanism and the formation of AgCu alloy. As a consequence, we observe a change of the wetting behavior and topology of both bulk and adsorbed Ag atoms by using Voronoi analysis (VA). Despite the differences in time scale, atomistic simulations allowed us to catch the early stages of wetting, which are important for explaining the final stage of wetting delivered from experiment. Our findings reveal also graphene translucency to metal-metal interactions, observed in previous papers.

15.
Materials (Basel) ; 15(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35009390

RESUMO

A spontaneous oscillation between the expansion and contraction of a nitrobenzene pendant droplet containing di-(2-ethylhexyl)phosphoric acid (DEHPA) was observed in an aqueous phase under alkaline conditions. We described this phenomenon as the spontaneous oscillation of the oil-water interfacial tension. The oscillation characteristics such as the induction period and the interfacial-tension oscillation frequency were investigated under different temperatures and aqueous phase polarities. The effects of the interfacial tension of the biphasic pendant-droplet, the surface excess of the surfactant molecules, and the amount of nitrobenzene elution from the droplet to the aqueous phase on the oscillation characteristics were investigated. Consequently, the periodic expansion-contraction oscillation mechanism was explained through the adsorption-desorption cycle of DEHPA with respect to the aggregate formation of the inverted micelle of DEHPA. This study was based on a simple vibration phenomenon of interfacial tension, and is extremely important for clarifying the predominant factors that cause fluctuations in the free interface energy, which has been ambiguous.

16.
J Nepal Health Res Counc ; 18(1): 108-111, 2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-32335603

RESUMO

BACKGROUND: The interval between stimulus and response is called reaction time. It measures the sensorimotor function and performance of an individual. It involves stimulus processing, decision making and response programming. Many factors such as age, gender, handedness, physical fitness, sleep, fatigue, distraction, personality type and type of stimulus have been shown to affect reaction time. Thus the aim of this study was to assess the effect of body mass index, handedness and gender on reaction time. METHODS: A cross-sectional study was conducted in the Department of Physiology, Kathmandu University School of Medical Sciences, from October 2019 to December 2019, among 113 student volunteers. Height and weight were recorded and body mass index was then calculated. In ruler drop method, the students were made to sit with their forearm resting on a flat horizontal table surface, with their open hand at the edge of the surface. When the examiner suspended and released the ruler vertically the students were instructed to catch it as quickly as possible. RESULTS: Females had a faster reaction time than males when testing either hand (178.46±17.56 Vs 195.99±15.67; right hand) and (184.25±17.02 Vs 199.57±15.91; left hand). In females, right hand responded faster than left hand. In both gender, reaction time was faster in normal weight compared to overweight individuals but it was statistically insignificant. CONCLUSIONS: Females responded faster than males. Right hand had shorter reaction time than left hand in females. Reaction time was insignificantly prolonged in overweight individuals.


Assuntos
Índice de Massa Corporal , Lateralidade Funcional/fisiologia , Tempo de Reação/fisiologia , Estudantes , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Nepal , Observação , Instituições Acadêmicas , Adulto Jovem
17.
Plants (Basel) ; 9(4)2020 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32295290

RESUMO

Leaf wettability has an impact on a plant's ability to retain water on its leaf surface, which in turn has many environmental consequences. In the case of the potato leaf (Solanum tuberosum L.), water on the leaf surface may contribute to the development of a fungal disease. If fungal disease is caused, this may reduce the size of potato harvests, which contribute significantly to meeting global food demand. The aim of this study was to assess the leaf wettability of five potato cultivars (i.e., Bryza, Lady Claire, Rudawa, Russet Burbank, Sweet Caroline) in the context of its direct and indirect impact on potato yield. Leaf wettability was assessed on the basis of contact angle measurements using a sessile drop method with an optical goniometer. For Bryza and Rudawa cultivars, which showed, respectively, the highest and the lowest contact angle values, light microscopy as well as scanning electron microscopy analyses were performed. The results of the contact angle measurements and microscopic image analyses of the potato leaf surfaces indicated that the level of wettability was closely related to the type of trichomes on the leaf and their density. Therefore, higher resistance of the Rudawa cultivar to biotic stress conditions could be the result of the presence of two glandular trichome types (VI and VII), which produce and secrete metabolites containing various sticky and/or toxic chemicals that may poison or repel herbivores.

18.
ACS Biomater Sci Eng ; 6(9): 4862-4869, 2020 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-33395269

RESUMO

As a first approach, standard 2D cell culture techniques are usually employed for the screening of drugs and nanomaterials. Despite the easy handling, findings achieved on 2D cultures are often not efficiently translatable to in vivo preclinical investigations. Furthermore, although animal models are pivotal in preclinical studies, more strict directives have been implemented to promote the use of alternative biological systems. In this context, the development and integration into preclinical research workflow of 3D neoplasm models is particularly appealing to promote the advancement and success of therapeutics in clinical trials while reducing the number of in vivo models. Indeed, 3D tumor models bridge several discrepancies between 2D cell culture and in vivo models, among which are morphology, polarity, drug penetration, osmolality, and gene expressions. Here, we comprehensively describe a robust and high-throughput hanging drop protocol for the production of 3D models of both Human Papillomavirus (HPV)-positive and HPV-negative head and neck squamous cell carcinomas (HNSCCs). We also report the standard cascade assays for their characterization and demonstrate their significance in investigations on these aggressive neoplasms. The employment of relevant 3D cancer models is pivotal to produce more reliable and robust findings in terms of biosafety, theranostic efficacy, and biokinetics as well as to promote further knowledge on HNSCC pathophysiology.


Assuntos
Neoplasias de Cabeça e Pescoço , Animais , Técnicas de Cultura de Células , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço/tratamento farmacológico , Nanomedicina Teranóstica
19.
J Colloid Interface Sci ; 561: 870-880, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-31771867

RESUMO

Phase change heat transfer (e.g., boiling of water) on surfaces can be enhanced by tuning the surface wettability, which is often quantified by the contact angle and is expected to be influenced by temperature and pressure. However, the temperature (and pressure) dependence of contact angles of water on metallic surfaces remain unclear. In this study, an in situ characterization of the contact angles of water on 304 stainless steel surfaces at temperatures from room temperature to 250 °C and at pressures up to 15 MPa was performed using the sessile drop method. It was shown that three distinct regimes can be identified on the contact angle-temperature curves. A slightly-decreasing trend of the contact angles with temperature was observed below 120 °C, followed by a steeper linear decrease at higher temperatures. A further rise of the decreasing rate with temperature was observed above 210 °C. In contrast to temperature, the pressure was shown to have little effects on the contact angles. Based on the theory of surface thermodynamics, the effects of temperature (and pressure) on the contact angles were analyzed in terms of the interfacial tensions. An empirical correlation was developed to predict the contact angles as a function of temperature.

20.
MethodsX ; 6: 1706-1715, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31384569

RESUMO

Quantification of interfacial tension (IFT) and contact angles is essential to characterize reservoir fluid-fluid and rock-fluid interactions. However, these measurements are highly dependent on chemical structure, surface residues, system conditions, flow dynamics and interface interactions. Interfacial interactions are specifically important for secondary and tertiary oil recovery processes where water or brine is injected to recover residual oil through complex multi-phase - rock/brine/oil- interactions Due to the delicate interactions across the interfaces, these systems are subjected to variations and inconsistencies that might be difficult to eliminate, thus, affecting the reliability, reproducibility, and certainty of the data. Therefore, reliable measurements need to eliminate fundamental sources of error and remove surface contaminants. To optimize these measurements, the presented methods take a holistic approach to carefully and reliably optimize the procedure for interfacial tension and contact angle measurements for fluid-fluid and rock-fluid interaction studies at ambient conditions (22.0 ±â€¯2 °C and atmospheric pressure). •The presented method ensures minimization of impurities that alter interfacial tension measurements;•Enhanced preparation for tested surfaces for contact angle measurements, and;•Optimization of procedure at ambient conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA