Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 574
Filtrar
1.
Ann Vasc Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960091

RESUMO

BACKGROUND: The unibody bifurcated aortic endograft (AFX/AFX2) has emerged as a treatment option for abdominal aortic aneurysms (AAAs). This systematic review and meta-analysis aimed to evaluate the safety of the unibody endograft. METHODS: A literature search was conducted in Cochrane Library, Scopus, Web of Science, and PubMed. Studies assessing the unibody endograft for abdominal aortic aneurysm repair between 2014 and 2023 were included. The defined primary outcomes were the incidences of type I, II, and III endoleaks. The secondary outcomes were access site problems, aneurysm-related mortality, aneurysm rupture, all-cause mortality, aneurysm sac growth, limb occlusion, stent graft migration, and technical success rate. RESULTS: 14 studies including 12 observational studies and two randomized controlled trials (RCTs) were included in the systematic review. The meta-analysis included 10 studies with 12,690 patients that reported the measured outcomes, and excluded four studies that did not. Type II endoleaks had the highest incidence of 12% (95% CI: 4-20%), followed by type III endoleaks with an incidence of 3% (95% CI: 1-5). The incidence of type I endoleaks was 1% (95% CI: 0-2%). A subgroup analysis by follow-up duration showed that type II endoleak incidence was higher after one to two years of follow-up than three to four years of follow-up. The incidence of aneurysmal mortality was 2% (95% CI: 0-7%); limb occlusion was 1% (95% CI: 0-1%); stent graft migration was 1% (95% CI: 0-2%); aneurysmal rupture was 6% (95% CI: 2-11%); access site problems were 7% (95% CI: 2-13%); aneurysm sac growth was 2% (95% CI: 0-4%);, all-cause mortality was 21% (95% CI: 4-38%), and technical success rate was 100% (95% CI: 98-100%). CONCLUSION: The unibody endograft is a safe and minimally invasive approach for AAA repair. However, potential complications necessitate close patient follow-up after the intervention.

2.
Circulation ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38989565

RESUMO

BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68-79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6-50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.

3.
Ann Vasc Surg ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39025219

RESUMO

BACKGROUND: Narrow and tortuous iliac axes, are the second most common reason the feasibility of EVAR, and low-profile endografts were conceived to overcome the limitation of narrow and tortuous iliac axes. This study aims to report the initial results of EVAR performed with the ultralow-profile Minos® abdominal endograft through a retrospective study conducted across three high-volume centers. MATERIALS AND METHODS: We retrospectively reviewed a prospectively maintained database collecting all consecutive EVAR performed with the Minos endograft across three Centers of Vascular Surgery between 2020 and 2023. Patients' clinical and operative data, perioperative and postoperative outcomes were recorded. RESULTS: 90 patients received EVAR with the Minos endograft. Assisted technical success was 100%, with 6 unplanned adjunctive procedures. Two perioperative complications required reinterventions: one access site surgical bleeding and an iliac limb occlusion. All unplanned adjunctive procedures and early reinterventions (8 in 7 patients) occurred in AAAs with hostile iliac arteries or narrow carrefour. Over a mean follow-up of 14.2±9.6 months, no deaths were observed, and all patients completed the scheduled surveillance protocol. Late reinterventions were 6 (6.7%): two type IA endoleaks, one type IB endoleak, one type II endoleaks, and two limb occlusions. There was no significant difference in reintervention rates between aneurysms with hostile and standard anatomy. CONCLUSION: The Minos endograft is safe and effective in treating aneurysms with hostile and standard anatomy, and its results are maintained at a mean follow-up of 14 months. A larger sample size and a longer follow-up are necessary to assess the results on the longer term.

4.
J Endovasc Ther ; : 15266028241258148, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38850041

RESUMO

PURPOSE: Thoracic endovascular aortic repair (TEVAR), originally conceived for deployment distal to the left subclavian artery (LSA), has been recently extended to more proximal landing zones. Among total endovascular solutions, the "Canaud technique" for Physician-Modified Thoracic Endovascular Grafts (C-PMEGs) has gained acceptance with good early results. The aim of this study is to report the proportion of patients with zone 0, 1, and 2 aortic arch lesions that could theoretically be treated with a C-PMEG. MATERIALS AND METHODS: Computed tomography angiography (CTA) of all consecutive patient candidates to open, hybrid, or endovascular arch repair from January 2009 to July 2023 at our Institution were analyzed. The assessment of feasibility of C-PEMG was conducted following previously extensively described anatomical criteria. RESULTS: During the study period, 209 consecutive patients were candidates for an open, hybrid, or endovascular aortic arch repair. Of them, 164 patients had a preoperative CTA scan eligible for analysis. One hundred twenty-six patients were male (76.8 %), with a mean age of 67 ± 10.8 years. Ninety-four patients (57.3%) were affected by atherosclerotic aneurysms, 48 post-dissecting aneurysms (29.3%) and 22 penetrating aortic ulcers (PAUs) (13.4%). Twenty patients (12.2%) were suitable for double-fenestrated C-PMEG, and 34 patients (20.7%) for single-fenestrated C-PMEG, totaling 32.9% of the entire cohort. The combination of supra-aortic trunks (SAT) bypass or the use of covered stent in IA or left common carotid artery (LCCA) as adjunctive maneuvers, would extend the C-PMEGs feasibility to 69 patients (42.1%). The use of an iliac graft conduit in 3 (1.8%) patients with inadequate ileo-femoral accesses would increase the C-PMEG suitability to 72 patients (43.9%). The main reason for exclusion was excessive ascending aortic diameter in 78 patients (47.6%). CONCLUSIONS: The use of C-PMEG was shown to be theoretically feasible in a percentage of patients ranging from 32.9 to 43.9% affected by aortic arch aneurysms, dissections, and PAU. The main reason for exclusion was the dimension of the ascending aorta. The C-PMEG technique is a viable option in aortic arch lesions endovascular treatment. An off-the-shelf device with similar characteristics could also be used in emergency, avoiding the limitations of physician modifications (such as time for back-table procedure, sterility, off-label use). CLINICAL IMPACT: Thoracic endovascular aortic repair (TEVAR) has been extended to more proximal landing zones for the treatment of aortic arch aneurysm, dissections, penetrating aortic ulcers. Among total endovascular solutions, the "Canaud technique" for Physician-Modified Thoracic Endovascular Grafts (C-PMEGs) has gained acceptance with good early results. The anatomical feasibility in 164 consecutive patients was 69 patients (42.1%), with the combination of supra-aortic trunks (SAT) bypass or the use of covered stent in IA or left common carotid artery (LCCA) as adjunctive maneuvers, showing that the C-PMEG technique is a viable option in aortic arch lesions endovascular treatment.

5.
J Clin Med ; 13(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38892771

RESUMO

Introduction: The aim of this paper is to propose a sequential deployment technique for the E-nside off-the-shelf endograft that could potentially enhance target visceral vessel (TVV) cannulation and overstenting in narrow aortic anatomies. Methods: All data regarding patients consecutively treated in two aortic centers with the E-nside graft employing the partial deployment technique were included in the study cohort and analyzed. To execute the procedure with partial endograft deployment, the device should be prepared before insertion by advancing, under fluoroscopy, all four dedicated 400 cm long 0.018″ non-hydrophilic guidewires until their proximal ends reach the cranial graft's edge. Anticipating this guidewire placement prevents the inability to do so once the endograft is partially released, avoiding potentially increased friction inside the constricted pre-loaded microchannels. The endograft is then advanced and deployed in the standard fashion, stopping just after the inner branch outlets are fully expanded. Tip capture is released, and the proximal end of the device is opened. Visceral vessel bridging is completed from an upper access in the desired sequence, and the graft is fully released after revascularizing one or more arteries. Preventing the distal edge of the graft from fully expanding improves visceral vessel cannulation and bridging component advancement, especially when dealing with restricted lumina. Results: A total of 26 patients were treated during the period December 2019-March 2024 with the described approach. Procedure was performed in urgent settings in 14/26 cases. The available lumen was narrower than 24 mm at the origin of at least one target vessel in 11 out of 26 cases performed (42.3%). Technical success was obtained in 24 out of 26 cases (92.3%), with failures being due to TVVs loss. No intraoperative death or surgical conversion was recorded, and no early reintervention was needed in the perioperative period. Clinical success at 30 days was therefore 80.7%. Conclusions: The described technique could be considered effective in saving space outside of the graft, allowing for safe navigation and target vessel cannulation in narrow visceral aortas, similar to what has already been reported for outer-branched endografts.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38879148

RESUMO

OBJECTIVE: To evaluate sex based differences in ascending aorta and arch anatomy in patients with underlying proximal aortic disease and to evaluate their impact on feasibility for total endovascular repair with custom made, branched arch devices. METHODS: This was a retrospective cross sectional review of all patients undergoing open and or total endovascular arch repair due to distal ascending aorta and or aortic arch pathologies in a single high volume aortic centre between 2012 and 2022. Anatomical ascending aorta and aortic arch parameters were analysed on a flow centreline on a dedicated 3D workstation. Sex related differences of the ascending aorta, aortic arch, and supra-aortic vessels were evaluated. Subsequently, four endovascular devices were assessed for feasibility: double and triple branched devices both for the Zenith (Cook Medical) and Relay (Terumo Aortic) platforms, first in accordance with the instructions for use and then considering the possibility of adjunctive cervical debranching. The primary endpoints were sex specific differences in aortic anatomy, while secondary endpoints included sex based feasibility of branched endograft devices. RESULTS: During the study period, 395 patients underwent total aortic arch repair, of whom 152 (51 female, 33.5%) had high quality computed tomography angiograms available and were included in the study. Female patients had a shorter proximal landing zone than males (22 mm vs. 47 mm; p < .001). Left subclavian artery dissection was more frequent in men (24.8% vs. 3.9%; p < .001). Other anatomical parameters showed a similar distribution between sexes. Female patients presented a lower feasibility for double branched devices (35.3% vs. 58.4%; p = .015) as well as a tendency for lower feasibility rates for triple branched devices (31.4% vs. 47.5%; p = .081). CONCLUSION: Although most ascending aortic and arch parameters showed similar trends in both sexes, the availability of a suitable proximal landing zone was lower in female patients. Consequently, female patients had lower feasibility rates for double arch branched endografts and, to lesser extent, for triple arch branched endografts.

7.
J Cardiovasc Dev Dis ; 11(5)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38786956

RESUMO

BACKGROUND: We conducted an in vitro comparison of the snare loop reinforcement against a closed-loop reinforcement (Hungaroring) for physician-modified endograft (PMEG) fenestrations regarding preparation time and stability during flaring balloon dilatation. MATERIALS AND METHODS: The time to complete a PMEG fenestration with reinforcement was measured and compared between the Hungaroring and snare loop groups. The number of stitches was counted. Each fenestration was dilated using a 10 mm high-pressure, non-compliant balloon up to 21 atm in pressure, and fluoroscopic images were taken. The presence of indentation on the oversized balloon at the level of the reinforcement was evaluated at each fenestration. RESULTS: Five fenestrations were created in each group (n = 5) for a total of ten pieces. The completion time in the snare loop group was 1070 s (IQR:1010-1090) compared to 760 s (IQR:685-784) in the Hungaroring group (p = 0.008). Faster completion time was achieved by faster stitching (23.2 s/stitch (IQR 22.8-27.3) for the snare loop group and 17.3 s/stitch (IQR 17.3-20.1) for the Hungaroring group (p = 0.016). None of the fluoroscopic images of the snare loop reinforcement showed an indentation on the balloon during the overexpansion; on the contrary, the Hungaroring showed indentation in every case, even at 21 atm. CONCLUSION: Fenestrations reinforced with Hungaroring can be completed significantly faster. Furthermore, the Hungaroring resists over-dilation even at high pressures, while snare loop reinforcements dilate at nominal pressure.

8.
J Vasc Surg Cases Innov Tech ; 10(3): 101491, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38699664

RESUMO

We describe the feasibility and safety of a standardized approach for four-fenestrated physician-modified endograft (PMEG) placement to treat complex abdominal aortic aneurysms using the Valiant Captivia platform (Medtronic). The standardization is based on specific selection criteria for anatomical feasibility, measurement method, and modification technique of a single endograft type. Six cases (two juxtarenal, two pararenal, and two type IV thoracoabdominal aneurysms) were treated, with 24 target vessels incorporated with fenestrations. Four cases were treated in an urgent setting and two were elective. The time modification required was 121 ± 18 minutes. Technical success was 100%, with no mortality or complications at 30 days. Postoperative computed tomography at 3 months demonstrated complete aneurysm exclusion, without a type I or III endoleak, no main graft- or fenestration-related loss of integrity, and no target vessel misalignment or stent fracture. The present standardized approach seems safe and feasible and might represent an initial benchmark for comparison with future studies.

9.
J Vasc Surg Cases Innov Tech ; 10(4): 101509, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38799649

RESUMO

A persistent sciatic artery (PSA) is a rare congenital vascular anomaly, with an estimated prevalence ranging from 0.01% to 0.05%. This condition can cause ischemic events in the lower limbs and sciatic artery aneurysms but can also be asymptomatic. A PSA can complicate the treatment of other coexistent vascular diseases due to the thin caliber of the external iliac and femoral arteries. We report a case of a patient with bilateral PSAs and an infrarenal aortic aneurysm. The aneurysm was successfully treated by the endovascular approach. An ultra-low profile endograft associated with access incisions slightly above the usual position was used to overcome this challenging access.

10.
J Endovasc Ther ; : 15266028241249571, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38721860

RESUMO

PURPOSE: This study aims to explore the feasibility and effectiveness of a unilateral transfemoral access endovascular salvage technique for complex abdominal aortic aneurysms with concurrent type Ia and Ib endoleaks following previous endovascular repair. CASE REPORT: A 69-year-old female with multiple comorbidities presented with an extent IV thoracoabdominal aortic aneurysm complicated by type Ia and Ib endoleaks and chronically occluded left iliac endoprosthesis after prior endovascular repair. Given the patient's medical complexities, open explant repair was deemed high risk. The case was successfully managed using a physician-modified fenestrated/branched endograft (PM-F/BEVAR) and an iliac branch device (IBD) deployed through a single percutaneous transfemoral access. CONCLUSION: The presented case demonstrates the safety and efficacy of PM-F/BEVAR with concomitant IBD deployment via unilateral transfemoral access. This innovative approach allows endovascular salvage in cases with restricted iliofemoral access and avoids the complexities associated with upper extremity or aortic arch manipulation. While acknowledging the technical challenges, this technique offers a viable alternative for salvaging failed endovascular repairs, emphasizing the importance of real-time modifications in achieving successful outcomes. Further studies and long-term follow-up are warranted to validate the broader applicability and durability of this approach in the management of complex abdominal aortic aneurysms with multiple endoleaks. CLINICAL IMPACT: Although not the conventional approach, unilateral transfemoral access can be utilized to implant either a physician-modified fenestrated aortic endograft or an iliac branch device. Such an approach avoids complicating issues related to upper extremity access. This innovative technique may be necessary when there is a failed prior EVAR in the setting of significant contralateral iliofemoral occlusive disease. Doing both procedures in the same setting to resolve a type Ia and Ib endoleak is feasible as demonstrated in this case report. Expanding the endovascular armamentarium to address EVAR failure will be increasingly useful in the future, especially given the morbidity profile of EVAR explantation.

11.
Artigo em Inglês | MEDLINE | ID: mdl-38777715

RESUMO

Thoracic endovascular aneurysm repair (TEVAR) has replaced open surgical repair as the treatment of choice for several aortic conditions. Despite its lower morbidity and mortality, several TEVAR-related complications can occur and some of which may necessitate surgical or endovascular re-intervention. The current article reviews common and rare complications of TEVAR procedure with emphasis on complications identifiable on cross-sectional imaging and potential pitfalls of pre-procedural planning.

13.
J Vasc Surg ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38677660

RESUMO

OBJECTIVE: The aim of this study was to demonstrate the safety and effectiveness of a low-profile thoracic endograft (19-23 French) in subjects with blunt traumatic aortic injury. METHODS: A prospective, multicenter study assessed the RelayPro thoracic endograft for the treatment of traumatic aortic injury. Fifty patients were enrolled at 16 centers in the United States between 2017 and 2021. The primary endpoint was 30-day all-cause mortality. RESULTS: The cohort was mostly male (74%), with a mean age of 42.4 ± 17.2 years, and treated for traumatic injuries (4% Grade 1, 8% Grade 2, 76% Grade 3, and 12% Grade 4) due to motor vehicle collision (80%). The proximal landing zone was proximal to the left subclavian artery in 42%, and access was primarily percutaneous (80%). Most (71%) were treated with a non-bare stent endograft. Technical success was 98% (one early type Ia endoleak). All-cause 30-day mortality was 2% (compared with an expected rate of 8%), with an exact two-sided 95% confidence interval [CI] of 0.1%, 10.6% below the performance goal upper limit of 25%. Kaplan-Meier analysis estimated freedom from all-cause mortality to be 98% at 30 days through 4 years (95% CI, 86.6%-99.7%). Kaplan-Meier estimated freedom from major adverse events, all-cause mortality, paralysis, and stroke, was 98.0% at 30 days and 95.8% from 6 months to 4 years (95% CI, 84.3%-98.9%). There were no strokes and one case of paraplegia (2%) during follow-up. CONCLUSIONS: RelayPro was safe and effective and may provide an early survival benefit in the treatment of blunt traumatic aortic injury.

14.
J Surg Res ; 299: 17-25, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38688237

RESUMO

INTRODUCTION: Physician-modified endografts (PMEGs) have been used for repair of thoracoabdominal aortic aneurysms (TAAAs) for 2 decades with good outcomes but limited financial data. This study compared the financial and clinical outcomes of PMEGs to the Cook Zenith-Fenestrated (ZFEN) graft and open surgical repair (OSR). METHODS: A retrospective review of financial and clinical data was performed for all patients who underwent endovascular or OSR of juxtarenal aortic aneurysms and TAAAs from January 2018 to December 2022 at an academic medical center. Clinical presentation, demographics, operative details, and outcomes were reviewed. Financial data was obtained through the institution's finance department. The primary end point was contribution margin (CM). RESULTS: Thirty patients met inclusion criteria, consisting of twelve PMEG, seven ZFEN, and eleven open repairs. PMEG repairs had a total CM of -$110,000 compared to $18,000 for ZFEN and $290,000 for OSR. Aortic and branch artery implants were major cost-drivers for endovascular procedures. Extent II TAAA repairs were the costliest PMEG procedure, with a total device cost of $59,000 per case. PMEG repairs had 30-d and 1-y mortality rates of 8.3% which was not significantly different from ZFEN (0.0%, P = 0.46; 0.0%, P = 0.46) or OSR (9.1%, P = 0.95; 18%, P = 0.51). Average intensive care unit and hospital stay after PMEG repairs were comparable to ZFEN and shorter than OSR. CONCLUSIONS: Our study suggests that PMEG repairs yield a negative CM. To make these cases financially viable for hospital systems, device costs will need to be reduced or reimbursement rates increased by approximately $8800.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Masculino , Feminino , Procedimentos Endovasculares/economia , Procedimentos Endovasculares/instrumentação , Idoso , Prótese Vascular/economia , Implante de Prótese Vascular/economia , Implante de Prótese Vascular/instrumentação , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/economia , Pessoa de Meia-Idade , Resultado do Tratamento , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/economia , Idoso de 80 Anos ou mais
15.
J Clin Med ; 13(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38673477

RESUMO

The number of endovascular aortic repairs (EVARs) has surpassed the number of open surgical repairs of abdominal aortic aneurysms (AAAs) worldwide. The available commercial endoprostheses are composed of materials that are stiffer than the native aortic wall. As a consequence, the implantation of stent-graft endoprostheses during EVAR increases aortic rigidity and thus aortic stiffness, resulting in a decrease in abdominal aorta compliance. EVAR has been found to have a possibly harmful effect not only on heart functions but also on other vascular beds, including kidney function, due to the decrease in aortic compliance that it causes. Aortic stiffness is measured by various hemodynamic indices like the pulse wave velocity (PWV), the central aortic pressure (CAP), and the augmentation index (AIx). In the literature, there are increasing numbers of studies investigating the properties of endografts, which are strongly related to increases in aortic stiffness. However, there is a lack of data on whether there is a correlation between the length of various endografts implanted during EVAR and the increase in the PWV, CAP, and AIx postoperatively compared to the preoperative values. The aim of this prospective, observational, monocentric, single-arm study is to investigate the correlation between endograft length and the postoperative increase in the PWV, CAP, and AIx in patients subjected to EVAR. Additionally, this study intends to identify other endograft properties related to increases in the PWV, CAP, and AIx. Other endpoints to be studied are the existence of immediate postoperative myocardial and kidney injury after EVAR. The prediction of cardiovascular events caused by endograft-related increased aortic stiffness could contribute to the improvement of various endograft properties so that the impact of endografts on the native aortic wall can be minimized.

16.
J Endovasc Ther ; : 15266028241245326, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605568

RESUMO

OBJECTIVE: This study aimed to assess the long-term outcomes in patients treated by thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injuries (BTAI). MATERIALS AND METHODS: From January 2010 to December 2019, this retrospective observational study was conducted at 3 centers, involving 62 consecutive BTAI patients who underwent TEVAR. Computed tomography angiography scans were planned to be conducted at 6 months post-procedure, and annually thereafter. RESULTS: Technical success was achieved in all 62 procedures (100%), which included cases of dissection (n=35, 56.45%), pseudoaneurysm (n=20, 32.26%), and rupture (n=7, 11.29%). Mean injury severity score was 31.66±8.30. A total of 21 supra-arch branches were revascularized by chimney technique, with 12 cases involving the left subclavian artery (LSA) and 9 cases involving the left common carotid artery. In addition, 11 LSAs were covered during the procedure. The in-hospital mortality rate was 1.61% (n=1). The mean follow-up time was 86.82±30.58 months. The all-cause follow-up mortality rate was 3.28% (n=2). Stenosis or occlusion of 3 supra-arch branches (4.92%) was identified at follow-up, with 2 cases (3.28%) requiring re-intervention. No spinal cord ischemia, endoleak, or migration was observed. CONCLUSIONS: Despite only including patients with long-term follow-up, this study confirms the long-term safety and effectiveness of TEVAR for BTAI. For young BTAI patients, as the thoracic aorta increases with age, longer follow-up is needed to observe the potential mismatch between the endograft and the aorta. CLINICAL IMPACT: This study confirms the long-term safety and effectiveness of endovascular treatment for blunt thoracic aortic injury (BTAI). For young BTAI patients, as the thoracic aorta increases with age, longer follow-up is needed to observe the potential mismatch between the endograft and the aorta. Through a remarkably extended follow-up period (86.82±30.58 months) conducted at multiple centers in China, this study confirms the long-term safety and effectiveness of endovascular treatment for BTAI.

17.
Clin Case Rep ; 12(5): e8814, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38686021

RESUMO

Key Clinical Message: Contraindications of spinal manipulative therapy (SMT) have been proposed, which mandate rigorous control for its safe practice when manipulating the upper spine. Here, we report a vascular complication of Neck Manipulation in Eagle syndrome (ES) patient. Abstract: SMT is used to treat musculoskeletal conditions such as back pain and neck pain by applying force to the spinal joints. Here, we report a rare but devastating complication of SMT, where a young male patient, 22 years old, with ES, had a large pseudoaneurysm from the internal carotid artery (ICA) after SMT from an unlicensed practitioner, treated successfully with endograft. Clinicians administering SMT should consider an elongated styloid process as a potential contraindication to this therapy.

18.
J Vasc Surg ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38608967

RESUMO

OBJECTIVE: Vascular graft and endograft infections (VGEIs) are complicated by high morbidity, mortality, and recurrence rates, notably due to biofilm formation on the graft surface, hardly dislodgeable by the sole anti-infectious treatment. The characteristics of this biofilm are still poorly documented. The aim of this study was to evaluate ex vivo biofilm on removed infected vascular grafts and endografts (VGEs). METHODS: Explanted VGEs were prospectively collected from 2019 to 2022 at Bordeaux University Hospital, France. Two samples per graft were used for scanning electron microscopy imaging; one was sonicated, and both grafts' sides were imaged. RESULTS: A total of 26 patients were included, 18 with VGEI, eight without any infection (endoleak and/or thrombosis), and 29 VGEs were collected. Microbial documentation was obtained in 83% of VGEIs. A thick layer of fibrin was visible on almost all grafts, mixed with a dense biofilm matrix on infected grafts visible as early as 1 month after the onset of infection. Bacteria were not always visualized on infected grafts' surface (80% on outer side and 85% on luminal side) but were surprisingly present on one-third of non-infected grafts. There was no significant difference between biofilm, fibrin, and microorganisms' distribution between the two grafts' sides. However, there were clear differences between infected and non-infected grafts, since immune cells, bacteria and biofilm were more frequently visualized on both sides of infected grafts (P < .05). Bacteria and immune cells although still visible, were significantly less present after sonication; the number of other elements including biofilm was not significantly different. CONCLUSIONS: The persistence of a thick layer of fibrin and biofilm embedding microorganisms on both sides of infected VGE even after 1 month of infection could be the explanation for the low success rates of conservative management and the usual need for graft removal to treat VGEIs.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38641315

RESUMO

OBJECTIVE: This multicentre study aimed to assess the early and midterm outcomes of physician modified fenestrated endografts (PMEGs) for endovascular aortic arch repair in zone 0. METHODS: Between 2018 and 2022, a retrospective study was conducted in three centres of consecutive patients undergoing endovascular aortic arch repair in zone 0 with PMEGs. Endpoints included technical success, 30 day mortality rate, major adverse events, secondary interventions, stent stability, target vessel patency, and overall survival. RESULTS: A total of 54 patients (mean age 63 years; 45 males) with aortic arch pathology were included, comprising aortic dissections (n = 32; 59%) and aortic arch aneurysms (n = 22; 41%). Technical success was 98%. One patient died from stroke within 30 days. Major adverse events included stroke (n = 4; 7%), retrograde type A dissection (RTAD) (n = 3; 6%), and acute kidney injury (n = 2; 4%). During a median follow up of 12 months, there were two deaths (4%) of unknown cause at one month and 1.5 months, and no aortic related death. Type Ia, type Ic, and type IIIc endoleaks were observed in two (4%), three (6%), and two (4%) patients, respectively. No vessel stenosis was observed. Re-intervention was required in 10 patients (19%). Estimates of overall survival, freedom from secondary intervention, and freedom from target vessel instability at one year were 94.2% (standard error [SE] 3.3%), 81.8% (SE 6.0%), and 92.0% (SE 4.5%), respectively. CONCLUSION: This study has demonstrated the efficacy of PMEGs for zone 0 endovascular aortic arch repair, with acceptable technical success and mortality rates. Stroke, RTAD, and re-intervention rates remain a concern for endovascular therapy. A larger population and long term outcomes are required to assess the safety and durability of this technique as a beneficial choice for endovascular aortic arch repair in specialised centres.

20.
Vasc Endovascular Surg ; 58(6): 663-668, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38527219

RESUMO

INTRODUCTION: Patients with complex aortic anatomy require meticulous surgical planning to optimize intraoperative and postoperative outcomes. The GORE Excluder Conformable Abdominal Aortic Aneurysm Endoprosthesis (CEXC Device, WL Gore and Associates, Flagstaff, AZ) allows for endovascular treatment of highly angulated and short proximal neck abdominal aortic aneurysms (AAA). Owing to its recent approval, short-term clinical outcomes of this device remain scarce. REPORT: In this report, we present a case series of 3 patients who underwent endovascular aortic repair using the GORE Excluder Conformable device with highly angulated (>70°) aortic neck anatomy. Endografts were deployed in a radiology suite using standard 2D angiography in conjunction with a CYDAR Medical (Wilmington, Delaware) reconstructed 3D overlay. The patients' ages were 85, 67, and 85 years. The mean abdominal aortic aneurysm diameter in these cases was 6.9 cm. The mean proximal neck length was 2.1 cm, proximal mean neck angulation was 83°. The mean operative time, total fluoroscopy time, and contrast used were 208 minutes, 28.3°minutes, and 94.5 milliliters, respectively. No adjunctive procedures, such as proximal cuff or endo-anchors, were performed at the time of index procedure. DISCUSSION: Type Ia endoleak was observed in 1 patient post-operatively but after treatment with an aortic cuff there was no evidence of enlarging aneurysm sac. The GORE Excluder Conformable Endoprosthesis expands access to endovascular management of AAAs. Our early experience with this device demonstrated excellent patient and clinical outcomes in a highly angulated neck anatomy.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Stents , Idoso , Idoso de 80 Anos ou mais , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...