Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
BMC Ophthalmol ; 24(1): 212, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750496

RESUMO

BACKGROUND: To evaluate differences in log MAR best-corrected visual acuity (BCVA) improvement and postoperative central foveal thickness (CFT) and choroidal thickness (CT) changes between conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS) for high-myopia cataracts. METHODS: This was a retrospective and observational study. One hundred and two eyes of 102 patients with high-myopia cataracts were examined. CPS was performed in 54 eyes, and FLACS was performed in 48 eyes. All eyes underwent logMAR BCVA, CFT and CT of three different sectors preoperatively and one week and six months postoperatively. RESULTS: The logMAR BCVA improved significantly after surgery in both groups (both P < 0.001), but no difference was observed in BCVA improvement between the groups (P = 0.554). Moreover, no significant differences were reflected in the changes in CFT, nasal 1 mm CT or temporal 1 mm CT between the two groups, and only subfoveal choroidal thickness (SFCT) in the CPS group decreased significantly compared with that in the FLACS group at any postoperative time (P = 0.003 and 0.026). AL, preoperative logMAR BCVA, and CT of the three regions exhibited a notable correlation with postoperative BCVA (all P < 0.05) according to univariate logistic regression analysis. However, only the AL, preoperative logMAR BCVA and SFCT remained significant in the multivariate model. Postoperative logMAR BCVA revealed a positive correlation with AL and preoperative logMAR BCVA but a negative correlation with SFCT. CONCLUSIONS: FLACS was not superior to CPS in improving BCVA but had less impact on SFCT in the treatment of high-myopia cataracts. Eyes with a longer AL, worse preoperative logMAR BCVA and thinner SFCT had a high risk of worse postoperative BCVA.


Assuntos
Catarata , Terapia a Laser , Facoemulsificação , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Estudos Retrospectivos , Feminino , Masculino , Facoemulsificação/métodos , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Idoso , Terapia a Laser/métodos , Catarata/complicações , Catarata/fisiopatologia , Tomografia de Coerência Óptica/métodos , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Extração de Catarata/métodos , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/cirurgia , Miopia Degenerativa/complicações , Corioide/diagnóstico por imagem , Resultado do Tratamento
2.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38711059

RESUMO

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Assuntos
Catarata , Núcleo do Cristalino , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Catarata/diagnóstico , Idoso , Pessoa de Meia-Idade , Núcleo do Cristalino/patologia , Núcleo do Cristalino/diagnóstico por imagem , Acuidade Visual/fisiologia , Curva ROC , Estudos Retrospectivos , Facoemulsificação , Idoso de 80 Anos ou mais , Adulto , Cristalino/diagnóstico por imagem , Cristalino/patologia
3.
Heliyon ; 10(9): e29780, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38699005

RESUMO

Objective: To evaluate and compare the magnitude of intraocular lens (IOL) decentration and tilt following conventional and femtosecond laser-assisted cataract surgery (FLACS) using swept-source anterior optical coherence tomography (SS-OCT). Methods: In this retrospective observational study, we enrolled patients who underwent conventional cataract surgery or FLACS with the implantation of hydrophobic 1-piece monofocal IOL. The magnitude of IOL decentration and tilt were measured using SS-OCT. Visual acuity, intraocular pressure, spherical equivalent, axial length, contrast sensitivity, and satisfaction questionnaire were evaluated before and one-month post-surgery. Additionally, postoperative internal cylinder measurements were obtained using a wavefront aberrometer. Correlation factors between each parameter and IOL decentration or tilt were analyzed. Results: This study included 100 eyes from 100 patients. Mean IOL decentration and tilt were 0.21 ± 0.13 mm and 5.01 ± 1.49°, respectively. Conventional cataract surgery (versus FLACS, P = 0.001) and male sex (versus female, P = 0.047) were significantly correlated with higher postoperative decentration. Preoperative lens diameter (P < 0.001), preoperative lens tilt (P = 0.007), and preoperative intraocular pressure (P = 0.027) were correlated with higher postoperative tilt. Fifty eyes that underwent FLACS demonstrated mean postoperative decentration of 0.21 ± 0.13 mm and tilt of 4.64 ± 1.48°. Compared with the conventional surgery group, the FLACS group significantly differed in postoperative decentration (0.30 ± 0.12 mm, P < 0.001) but not in tilt (5.03 ± 1.35°, P = 0.173). Postoperative visual acuity did not significantly differ between the two groups. Conclusion: Patients who underwent FLACS demonstrated better IOL decentration and tilt than those who underwent conventional cataract surgery one-month post-surgery. However, differences in IOL decentration and tilt did not affect postoperative visual acuity.

4.
Curr Eye Res ; : 1-11, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780904

RESUMO

PURPOSE: To evaluate the effectiveness and stability of refractive astigmatism reduction after penetrating femtosecond laser-assisted arcuate keratotomy performed at the time of femtosecond laser-assisted cataract surgery. METHODS: Non-randomized retrospective data analysis of all patients that underwent femtosecond laser-assisted cataract surgery with femtosecond laser-assisted arcuate keratotomy over a 4-year period with a non-toric monofocal intraocular lens (2017-2021) at a tertiary care academic center. Postoperative visual acuity, manifest refraction, and predicted residual refractive error were also recorded at 1 month, 3-6 months, 12-18 months, and 2 years postoperatively. Preoperative keratometric astigmatism was compared to postoperative refractive astigmatism using vector calculations and the ASCRS double-angle plot tool. RESULTS: This study comprised 266 eyes (179 patients) that met inclusion criteria. The mean preoperative keratometric astigmatism magnitude was 0.99 ± 0.53 D. At 1 month, 3-6 months, 12-18 months, and 2 years postoperatively, the mean refractive cylinder was 0.49 ± 0.45 D, 0.49 ± 0.45 D, 0.55 ± 0.54 D, and 0.52 ± 0.46 D, respectively. Horizontal against-the-rule astigmatism showed a higher tendency toward undercorrection than vertical with-the-rule astigmatism, which had a slightly higher tendency toward overcorrection. With-the-rule astigmatism had smaller difference vectors between target-induced astigmatism and surgically induced astigmatism. CONCLUSIONS: Femtosecond laser-assisted arcuate keratotomy performed at the time of femtosecond laser-assisted cataract surgery was an effective option for correcting low-to-moderate corneal astigmatism for up to 2 years.

5.
Biomolecules ; 14(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38540738

RESUMO

PURPOSE: This study was conducted to evaluate the effects of different capsulotomy and fragmentation energy levels on the production of oxidative free radicals following femtosecond laser-assisted cataract surgery (FLACS) with a low-energy platform. METHODS: The experimental study included 60 porcine eyes (12 groups). In each group, capsulotomies with 90% or 150% energy, and fragmentations with 90%, 100%, or 150% energy or 150% with high spot density, respectively, were performed. Control samples were obtained from non-lasered eyes at the beginning (five eyes) and end (five eyes) of the experiment. In the clinical study, 104 eyes were divided into 5 groups, and they received conventional phacoemulsification (20 eyes), FLACS with 90% capsulotomy and 100% fragmentation energy levels without NSAIDs (16 eyes), FLACS with 90% (26 eyes) or 150% (22 eyes) capsulotomy energy levels, respectively, with a 100% fragmentation energy level and NSAIDs, and FLACS with 90% capsulotomy and 150% fragmentation energy levels and NSAIDs (20 eyes). Aqueous samples were analyzed for their malondialdehyde (MDA) and superoxide dismutase (SOD) levels. RESULTS: In the experimental study, there were no significant differences in the MDA and SOD levels between the groups with different capsulotomy energy levels. An increase in the fragmentation energy from 100% to 150% led to significantly higher MDA levels in the groups with both 90% (p = 0.04) and 150% capsulotomy energy levels (p = 0.03), respectively. However, increased laser spot densities did not result in significant changes in MDA or SOD levels. In the clinical study, all four of the FLACS groups showed higher MDA levels than the conventional group. Similarly, the increase in the fragmentation energy from 100% to 150% resulted in significantly elevated levels of MDA and SOD, respectively. CONCLUSIONS: Although increasing the FSL capsulotomy energy level may not have increased free radicals, higher fragmentation energy levels increased the generation of aqueous free radicals. However, fragmentation with high spot density did not generate additional oxidative stress. Increased spot density did not generate additional oxidative stress, and this can be helpful for dense cataracts.


Assuntos
Catarata , Terapia a Laser , Humanos , Terapia a Laser/métodos , Catarata/terapia , Lasers , Estresse Oxidativo , Radicais Livres , Anti-Inflamatórios não Esteroides , Superóxido Dismutase
6.
International Eye Science ; (12): 436-440, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1011397

RESUMO

AIM: To explore the effects of femtosecond laser-assisted cataract surgery combined with intraocular lens implantation(FLACS-IOL)on postoperative deviation rate of multifocal intraocular lens(MIOL)and visual quality in cataract patients.METHODS: In the prospective study, 95 patients with cataract(108 eyes)who underwent MIOL implantation in the hospital between January 2021 and December 2022 were enrolled. According to different surgical methods, they were divided into FLACS group(51 cases, 56 eyes)and Phaco group(44 cases, 52 eyes). The operation time, incision diameter of anterior capsule, effective phaco time(EPT), cumulative dissipated energy(CDE), uncorrected distance visual acuity(UCDVA), best corrected distance visual acuity(BCDVA), eccentricity distance of IOL and deviation rate at 3 mo after surgery, total high order aberration(HOA), Trefoil and coma under 3 mm pupil were compared between the two groups.RESULTS: The operation time in the FLACS group was significantly shorter than that in the Phaco group, EPT and CDE were significantly lower than those in the Phaco group(all P&#x003C;0.05). There was no significant difference in incision diameter of anterior capsule between the two groups(P&#x003E;0.05). At 1 wk, 3 mo after surgery, UCDVA in the FLACS group was better than that in the Phaco group(all P&#x003C;0.05). There were significant difference in UCDVA at 1 wk, 3 mo after surgery or BCDVA at 3 mo after surgery between the two groups(P&#x003C;0.05). At 3 mo after surgery, eccentricity distance of IOL in the FLACS group was shorter than that in the Phaco group, and deviation rate was significantly lower than that in the Phaco group(all P&#x003C;0.05). Under pupil diameter of 3 mm, HOA, trefoil and coma of whole eyes were decreased in both groups at 3 mo after surgery(P&#x003C;0.05). At 3 mo after surgery, there were significant differences in HOA and trefoil of whole eyes between the FLACS group and Phaco group(P&#x003C;0.05), but there was no significant difference in coma at 3 mo after surgery(P&#x003E;0.05).CONCLUSION: FLACS-IOL can effectively reduce deviation rate of IOL and obtain better visual quality in cataract patients.

7.
Korean J Ophthalmol ; 38(1): 9-16, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38110185

RESUMO

PURPOSE: We aimed to compare the accuracy of the intraocular lens (IOL) calculation formula using the standard keratometry (K) and total K (TK) during the femtosecond laser-assisted cataract surgery (FLACS) with a monofocal IOL with enhanced intermediate function using currently used formulas. METHODS: A retrospective review of 125 eyes from 125 patients who had undergone FLACS with implantation of monofocal IOL with enhanced intermediate function was conducted. The predicted refractive power was calculated using an optical biometer (IOLmaster 700) according to the K and TK in the Barrett Universal II, SRK/T, Haigis, and Holladay 2 formulas. Absolute prediction error (APE) obtained from the actual postoperative refractive outcomes and the refractive error predicted in each formula was compared one month after surgery. RESULTS: Mean APE ranged between 0.29 and 0.39 diopters (D) regardless of the calculation formula and the method of measuring corneal curvature. Significant differences were observed in the APE from the four formulas and the two keratometric measurements (p = 0.014). In a total of 125 eyes from 125 patients, the mean APE was lowest with the Barrett Universal II formula. Across all formulas, both the mean APE and the median APE tended to be lower for K than for TK, although there was no significant difference. Approximately 70% to 80% of the patients were included within 0.5 D of the refractive error across all formulas. The percentage of eyes within 0.5 D of APE outcomes was not statistically different between the K and TK data when using each formula. CONCLUSIONS: Keratometric measurements considering the poster corneal curvature did not show any additional advantages when implanting the monofocal IOL with enhanced intermediate function during the FLACS.


Assuntos
Catarata , Hominidae , Lentes Intraoculares , Facoemulsificação , Erros de Refração , Humanos , Animais , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Refração Ocular , Estudos Retrospectivos , Biometria/métodos , Lasers
8.
Int J Ophthalmol ; 16(11): 1773-1781, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028512

RESUMO

AIM: To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery (FLACS) combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses (IOL). METHODS: During this retrospective observational study, patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated. According to the IOLs' different types and design, the patients were divided into AT LISA tri839MP group (tri839 group) and AcrySof PanOptix TFNT00 group (TFNT group). Study parameters included preoperative and postoperative uncorrected distance visual acuity (UDVA) at 5 m, uncorrected near visual acuity (UNVA) at 30 cm and 40 cm, uncorrected intermediate visual acuity (UIVA) at 60 cm and 80 cm, postoperative refractive status, objective visual qualities and total high order aberrations (HOAs) postoperatively. The postoperative complications were also recorded. RESULTS: Totally 56 eyes of 28 patients (tri839 group, n=26; TFNT group, n=30) were included. Preoperative baseline characteristics between groups were not statistically significantly different. UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema. TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk (0.05±0.19 vs 0.15±0.10 logMAR, P=0.013), 1mo (0.05±0.12 vs 0.15±0.09 logMAR, P=0.001) and 3mo (0.04±0.12 vs 0.15±0.11 logMAR, P=0.001) follow-up, while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d (0.14±0.15 vs 0.20±0.14 logMAR, P=0.041) and 1mo (0.09±0.07 vs 0.14±0.10 logMAR, P=0.042) follow-up. Postoperative refractive status showed stable at every visit. Modulated transfer function (MTF) values and strehl ratio (SR) values were improved and HOAs were lower significantly after surgery. CONCLUSION: FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision, high postoperative refractive stability and good visual quality but without significantly difference. iTrace aberration instrument can accurately evaluate the visual quality under different status.

9.
Clin Ophthalmol ; 17: 2983-2996, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37841901

RESUMO

Purpose: We evaluate the reduction of corneal astigmatism and the improvement of visual outcomes of this surgical method in the Indonesian population. We also assess the accuracy and predictability of using femtosecond laser astigmatic keratotomy (FLAK) combined with cataract surgery. Patients and Methods: In a retrospective study, a total of 275 subjects (78 with against-the-rule (ATR) astigmatism, 178 with with-the-rule (WTR) astigmatism, and 19 with oblique (OBL) astigmatism) with preexisting corneal astigmatism ranging from 0.75D to 3.00D underwent FLAK. All subjects completed a 3-month follow-up. The femtosecond laser used for creating paired AK 2.2 mm, primary incision, and paracentesis incision was the FEMTO Z8 NEO from Ziemer Ophthalmic System, Switzerland. The surgical approach was guided by the "NAPA" nomogram. Results: The reduction in postoperative astigmatism was 56.90% for the WTR group, 49.46% for the ATR group, and 47.33% for the oblique group. A significant reduction in astigmatism was observed at the 1-week, 1-month, and 3-month follow-up intervals in both the WTR and ATR groups. The reduction in astigmatism was more favorable in cases of moderate astigmatism within the WTR group, as compared to the ATR and oblique groups. Postoperative astigmatism reduction was found to be more predictable in the right eye than in the left eye. Conclusion: The combination of FLAK can be considered as a potential method for reducing corneal astigmatism ranging from 1.00D to <3.00D. The highest reduction was observed in the WTR group, along with a higher rate of intended correction without astigmatism meridian shift in the right eye for the WTR group. However, factors such as cyclotorsion resulting from the surgical technique, alignment of docking, incision length, and preoperative astigmatism need to be taken into account for further enhancement and predictability of astigmatism reduction with this method.

10.
Int J Ophthalmol ; 16(7): 1084-1092, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37465507

RESUMO

AIM: To evaluate corneal astigmatic outcomes of femtosecond laser-assisted arcuate keratotomies (FAKs) combined with femtosecond-laser assisted cataract surgery (FLACS) over 12mo follow-up. METHODS: Totally 145 patients with bilateral cataracts and no ocular co-morbidities were recruited to a single-centre, single-masked, prospective randomized controlled trial (RCT) comparing two monofocal hydrophobic acrylic intraocular lenses. Eyes with corneal astigmatism (CA) of >0.8 dioptres (D) received unpaired, unopened, surface penetrating FAKs at the time of FLACS. Visual acuity, subjective refraction and Scheimpflug tomography were recorded at 1, 6, and 12mo. Alpins vectoral analyses were performed. RESULTS: Fifty-one patients (61 eyes), mean age 68.2±9.6y [standard deviation (SD)], received FAKs. Sixty eyes were available for analysis, except at 12mo when 59 attended. There were no complications due to FAKs. Mean pre-operative CA was 1.13±0.20 D. There was a reduction of astigmatism at all post-operative visits (residual CA 1mo: 0.85±0.42 D, P=0.0001; 6mo: 0.86±0.35 D, P=0001; and 12mo: 0.90±0.39, P=0.0001). Alpins indices remained stable over 12mo. Overall, the cohort was under-corrected at all time points. At 12mo, 61% of eyes were within ±15 degrees of pre-operative astigmatic meridian. CONCLUSION: Unpaired unopened penetrating FAKs combined with on-axis phacoemulsification are safe but minimally effective. CA is largely under-corrected in this cohort using an existing unmodified nomogram. The effect of arcuate keratotomies on CA remained stable over 12mo.

11.
Eye Vis (Lond) ; 10(1): 31, 2023 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-37393278

RESUMO

BACKGROUND: To compare the safety and efficacy of femtosecond laser-assisted cataract surgery (FLACS) performed with the low-energy FEMTO LDV Z8 (Ziemer Ophthalmic Systems AG, Port, Switzerland) laser compared with conventional phacoemulsification (CP) in Chinese patients. METHODS: This prospective, multicenter, interventional study included 126 patients who were randomized (1:1) to undergo either FLACS or CP followed by intraocular lens (IOL) implantation between January 2019 and April 2020. The primary endpoint included the comparison of the endothelial cell loss (ECL) between the two groups at 3 months. Secondary endpoints included the comparison of cumulative dissipated energy (CDE), change in central corneal thickness (CCT) from baseline, and postoperative uncorrected and corrected distance visual acuities (UDVA and CDVA) in the two groups. RESULTS: At all postoperative time points, the FLACS group was found to be non-inferior to CP for the mean ECL (- 409.3 versus - 436.9 cells/mm2 at 3 months) and mean CDE (4.1 versus 4.5 percent-seconds). The increase in CCT was significantly lower in the FLACS group compared with the CP group at Day 7 (4.9 versus 9.2 µm; P = 0.04); however, the difference was not statistically significant at 1 and 3 months. Postoperatively, mean UDVA and CDVA were comparable between the two groups. No intraoperative complications occurred. CONCLUSIONS: Cataract surgery performed with a low-energy femtosecond laser was non-inferior to CP; however, the FLACS group had a statistically significantly lower increase in CCT at Day 7 compared with CP. Trial registration This trial is registered at ClinicalTrials.gov on May 15, 2019, with trial registration number: NCT03953053.

12.
Medicina (Kaunas) ; 59(4)2023 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-37109597

RESUMO

Background: The aim of the study was to compare macular thickness behavior and clinical outcomes after femtosecond laser-assisted cataract surgery (FLACS) versus phacoemulsification conventional surgery (PCS). Methods: Macular Optical Coherence Tomography OCT was analyzed in 42 patients preoperatively, 1 day, 12 days, 4 weeks and 6 weeks postoperatively according to the 9-field Early Treatment Diabetic Retinopathy Study (ETDRS) grid. Clinical findings were collected in both the FLACS group and the PCS group. Results: There was no significant difference in macular thickness between the FLACS and PCS groups (p > 0.05). However, from postoperative day 12 onwards, there was a significant increase in macular thickness observed in both groups (p < 0.001). In the FLACS group, a significant increase in visual acuity was observed on the first postoperative day, as compared to the PCS group (p = 0.006). Conclusions: The use of a low-energy high-frequency femtosecond laser has potentially no effect on postoperative macular thickness. In the FLACS group, visual rehabilitation was significantly faster as compared to the PCS group. No complications occurred intraoperatively in either group.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Facoemulsificação , Humanos , Terapia a Laser/métodos , Facoemulsificação/métodos , Lasers
13.
BMC Ophthalmol ; 23(1): 166, 2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37076866

RESUMO

PURPOSE: To evaluate the effects of a novel technique using an isolated lens anterior capsule disc (LACD) to protect corneal endothelial cells in rabbit eyes during femtosecond laser-assisted cataract surgery. METHODS: Experimental study. 40 rabbits were divided into endothelium-protected (experimental) and control groups, with 20 rabbits in each group. In the experimental group, after femtosecond laser capsulotomy, the isolated capsule disc was lifted to the corneal endothelium by an ophthalmic viscosurgical device. The endothelium was damaged for 1 min with an ultrasonic probe. The control group underwent the same surgery, except that the disc was removed immediately after capsulorhexis. Corneal endothelioscopy was performed preoperatively and on postoperative days (PODs) 3 and 7 to observe endothelial cell counts (ECC) and endothelial cell loss rate. Central corneal thickness (CCT) was measured before and at PODs 1, 3 and 7. RESULTS: There were 3.59%±1.88% (p < 0.001) and 2.92%±2.14% (p < 0.001) loss of ECC in experimental group at POD3 and POD7, respectively, while those in the control group were 11.62%±7.43% and 10.34%±5.77%, respectively. On POD 1, the difference in central corneal thickness was significant(P = 0.019) between the two groups. At POD 3 and POD 7, CCT was not significantly different (P = 0.597;0.913) between the two groups. CONCLUSIONS: The isolated LACD technique significantly reduced damage to the endothelium caused by ultrasonic energy and protects corneal endothelial cells during phacoemulsification.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Implante de Lente Intraocular , Facoemulsificação , Animais , Coelhos , Extração de Catarata/métodos , Córnea , Células Endoteliais , Endotélio Corneano , Terapia a Laser/métodos , Lasers , Facoemulsificação/métodos , Estudos Prospectivos
14.
Front Med (Lausanne) ; 10: 1131314, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36936227

RESUMO

Cataract surgery is among the most frequently performed surgical procedures worldwide and has a tremendous impact on patients' quality of life. Phacoemulsification (PCS) is accepted as a standard of care; its technique has continuously evolved and already achieved good anatomical, visual, and refractive outcomes. Lasers in ophthalmology are widely used in clinical practice, femtosecond lasers (FSLs) for corneal surgery in particular. It was natural to assess the usefulness of FSL in cataract surgery as this technology was within reach. Indeed, precise and reproducible cuttings provided by FSL platforms could improve standardization of care and limit the risk associated with the human element in surgery and provide a step toward robot-assisted surgery. After docking and planning the procedure, femtosecond lasers are used to perform corneal incisions, capsulorhexis, lens fragmentation, and arcuate incisions in an automated manner. A well-constructed corneal incision is primordial as it offers safety during the procedure, self-seals afterward, and influences the refractive outcome. Capsulorhexis size, centration, and resistance to shearing influence the surgery, intraocular lens (IOL) centration and stability, and posterior capsular opacification formation. Lens fragmentation is where most of the energy is delivered into the eye, and its amount influences endothelial cell damage and potential damage to other ocular structures. The arcuate incisions offer an additional opportunity to influence postoperative astigmatism. Femtosecond laser-assisted cataract surgery (FLACS) has been a topic of research in many studies and clinical trials that attempted to assess its potential benefits and cost-effectiveness over PCS and is the subject of this mini-review.

15.
Am J Ophthalmol Case Rep ; 29: 101764, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36561882

RESUMO

Purpose: The Argentinian flag sign, or radial capsular tear extensions, is a rare complication when performing capsulorhexis during cataract surgery. Identifying and managing this complication early is important to prevent the tear from propagating around the periphery leading to posterior capsular rupture or vitreous loss. Observations: The Argentinian flag sign was previously reported in a case of femtosecond laser-assisted cataract surgery (FLACS). However, our report presents the first case after FLACS using the Catalys™ Precision Laser System, a platform which has been associated with a larger percentage of complete capsulotomies when compared to other platforms. Radial extensions of the capsular tear were observed in a 27-year-old male patient with an intumescent cataract in left eye. The complication was managed by manually redirecting and completing the radial extension flaps, along with delicate phacoemulsification and manual cutting of capsular edge in areas with significant capsular-IOL overlap. Conclusions and importance: Our case report highlights that despite the Catalys™ Precision Laser System success rates, radial tears may occur, especially in highly pressurized intumescent cataract. Therefore, surgeons must be prepared to optimize the surgical techniques to prevent the occurrence of this complication, as well as identify and manage it when it presents.

16.
Eur J Ophthalmol ; 33(3): 1373-1379, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36575599

RESUMO

PURPOSE: Femtosecond laser-assisted cataract surgery (FLACS)'s effect on reducing ultrasound energy, accumulated with cumulative dispersed energy (CDE) units, still remains controversial. This study aims to evaluate the effect of low-energy FLACS on CDE with that of conventional phacoemulsification surgery (CPS) in different cataract densities from multiple surgeons. METHODS: It was a retrospective case-control study. Total 629 eyes receiving either low-energy FLACS (performed with Ziemer LDV Z8 platform) or CPS were divided into two groups according to preoperative grading of Lens Opacity Classification System III (LOCSIII): milder and harder cataract group. The mean CDE were compared in different cataract densities and surgeons. A linear regression analysis was performed to evaluate the effect of using low-energy FLACS on CDE in harder cataract cases. RESULTS: We found overall CDE had no significant difference between two surgeries. However, low-energy FLACS led to a significantly lower CDE in patients with harder cataracts than CPS (18.47 ± 4.32 vs. 12.96 ± 2.34; p < 0.001). Similar results were observed in the three surgeon subgroups and in linear regression analysis and no significant difference of the effect accounting for surgeons. Moreover, low-energy FLACS results in a reduction of energy consumption comparing to CPS and has endothelial sparring effect in patients with harder cataracts. CONCLUSIONS: The reduced energy consumption was observed by using low-energy FLACS irrespective of surgeons' experience or the approaches adopted in patients with harder cataracts. Therefore, we can have more confidence to suggest this innovative platform to the patients in such cases.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Facoemulsificação , Humanos , Facoemulsificação/métodos , Estudos Retrospectivos , Estudos de Casos e Controles , Terapia a Laser/métodos , Acuidade Visual , Extração de Catarata/métodos , Catarata/complicações , Lasers
17.
Int Ophthalmol ; 43(1): 285-292, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35870049

RESUMO

PURPOSE: To evaluate the association between postoperative intraocular pressure (IOP) reduction and phacoemulsification parameters in patients who underwent both conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a prospective multicenter comparative study that enrolled 90 participants who underwent cataract surgery at the University of Maryland Medical System and the Wilmer Eye Institute. Patients underwent FLACS in one eye and CPS in the fellow eye. IOP was measured prior to surgery and monitored through six months postoperatively. Demographic, clinical, biometric, and intraoperative variables including cumulative dissipated energy (CDE), aspiration time, and phacoemulsification time were analyzed for any significant association with postoperative IOP. Postoperative IOP reduction was the primary outcome variable. A secondary goal of the study was to determine differences in postoperative IOP reduction between CPS and FLACS cohorts. RESULTS: In total, 157 non-glaucomatous eyes were included. Using multivariable analysis, we found preoperative IOP to be consistently associated with postoperative IOP reduction in the entire cohort. At the 6-month follow-up visit, there was a 12.4% reduction in IOP (-2.2 ± 3.4 mm Hg) seen, with no statistically significant difference between FLACS and CPS (12.3% ± 19.4% vs 12.5% ± 19.3%, respectively, p = 0.32). FLACS reduced the CDE required for phacoemulsification (6.6 ± 4.4%-seconds vs 8.6 ± 6.9%-seconds, respectively, p < 0.05). CDE was a predictor of IOP response at 6 months, but subgroup analysis revealed that this trend was driven by seven eyes requiring high CDE, and for the majority of eyes, CDE did not influence the size of the decrease. The seven eyes experiencing highest CDE were less likely to show IOP reduction at 6 months. CONCLUSION: Both FLACS and CPS resulted in similar and significant IOP reductions through 6 months after surgery. Preoperative IOP was significantly associated with IOP reduction, and CDE generally did not influence the size of the decrease.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Facoemulsificação , Humanos , Facoemulsificação/métodos , Pressão Intraocular , Estudos Prospectivos , Terapia a Laser/métodos , Acuidade Visual , Extração de Catarata/métodos , Lasers
18.
International Eye Science ; (12): 325-328, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-960960

RESUMO

AIM: To measure the indexes including postoperative distance, middle, near visual acuity and near stereopsis vision of patients with high myopia cataract and corneal astigmatism by femtosecond laser, which can quantify the diameter of capsulorhexis opening, and to evaluate the availability and necessity of Toric intraocular lenses(IOL)in high myopia.METHODS: Prospective case-control study. Patients with binocular high myopia cataract and corneal astigmatism who undergone femtosecond laser-assisted cataract surgery in our hospital were selected, and they were divided into two groups, with 20 cases(40 eyes)in group A(Toric IOL)and 20 cases(40 eyes)in group B(IQ IOL). Indexes, including preoperative corneal astigmatism and spherical equivalent and best-corrected distance visual acuity, uncorrected middle visual acuity, uncorrected near visual acuity, residual refractive astigmatism, near stereopsis acuity, total high-order aberration and total spherical aberration, were measured postoperatively at 7d, 1 and 3mo.RESULTS: The uncorrected middle and near visual acuity, Titmus near stereopsis acuity and residual astigmatism at 7d, 1 and 3mo after surgery were significantly improved in the Toric IOL group than the non-Toric group(all P&#x0026;#x003C;0.05). The dependence on glasses was reduced. The postoperative best-corrected distance visual acuity, total high-order aberration and total spherical aberration of the two groups showed no statistically significant differences(all P&#x0026;#x003E;0.05).CONCLUSIONS: The implantation of Toric IOL in patients with high myopia cataract and corneal astigmatism can effectively correct corneal astigmatism, improve postoperative uncorrected middle and near visual acuity and near stereopsis visual function, reduce postoperative dependence on glasses and enhance binocular stereopsis visual function.

19.
International Eye Science ; (12): 312-315, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-960957

RESUMO

AIM: To evaluate the clinical efficacy of femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation.METHODS:The retrospective study enrolled 22 cases(26 eyes)of cataract patients who underwent femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation from August 2020 to August 2021. Follow-up to 3mo after surgery, the changes of far, intermediate and near visual acuity, aberration, Strehl ratio(SR)and modulation transfer function cutoff(MTF-cutoff)frequency were compared. Defocus curve at 1mo postoperatively was made, and the visual quality and satisfaction were evaluated after 3mo of surgery.RESULTS: The visual acuity of all patients was better than 0.1(LogMAR)at the far, intermediate and near distance at 1d, 1wk, 1 and 3mo postoperatively, and it was significantly improved compared with those before surgery(all P&#x0026;#x003C;0.01). The defocus curve transitioned smoothly between +0.5 and -3.0D at 1mo after surgery, and visual acuity was better than 0.63. The total aberration and spherical aberration in the whole eye were significantly lower after surgery than before, and the SR and MTF-cutoff were significantly improved at 1d and 1wk after surgery(all P&#x0026;#x003C;0.05). With high satisfaction and good visual quality, patients could watch at far, intermediate and near distance without wearing glasses at 3mo after surgery.CONCLUSION: Femtosecond laser-assisted cataract surgery combined with PanOptix trifocal intraocular lens implantation gave patients a comfortable and satisfactory full-course vision.

20.
Vision (Basel) ; 6(4)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36548934

RESUMO

The aim of this work is to compare the time of surgical phases and the cumulative dissipated energy (CDE) of the phacoemulsification phase in femtosecond laser-assisted cataract surgery (FLACS) and in standard surgical procedures of phacoemulsification (PCS). This prospective, non-randomized study analyzed the data of 100 cataract surgeries, 66 using FLACS and 34 with standard PCS. The time of surgical phases was recorded by a digital chronometer; an additional parameter recorded was the CDE of the phacoemulsification phase. The mean time of femtosecond laser phase was 121.7 ± 27.3 s with minimal fluctuations in duration; the mean opening time of the corneal tunnel and the service incisions was 60.5 ± 20.4 s in the PCS, and 48.8 ± 17.4 s in FLACS (p = 0.04); the mean time of capsulorhexis was 39.6 ± 12.9 s in the PCS and 7.0 ± 5.2 s in FLACS (p < 0.0001); the mean time of phacoemulsification was 180.1 ± 45.6 s in the PCS and 163.0 ± 38.2 s in FLACS (p = 0.12); the mean aspiration time of the residual cortical was 66.3 ± 27.5 s in the PCS and 91.5 ± 35.7 s in FLACS (p = 0.02). Overall, the total surgical time of the cataract surgery was 742.3 ± 185.8 s in PCS and 985.1 ± 118.6 s in FLACS (p = 0.03). The mean CDE was 11.35 in the PCS and 8.3 in FLACS (p = 0.01). In conclusion, the greatest advantage obtained from the use of the femtosecond laser was the reduction of the duration of the phacoemulsification time and of the CDE parameter.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...